Home
SB825 User Manual - Legacy Power Conversion
Contents
1. User s Manual Legend SB825 UPS KO1 1120009 00 IE LEGACY TABLE OF CONTENTS IMPORTANT SAFETY WARNINGS enen en en eneen eneen eenen 1 INSTALLING YOUR UPS SYSTEM cece eee eee eee eee enen verenenen ven enen 2 I cece eee etre em ee ee ete nett esate neta eee cece ates 2 HARDWARE INSTALLATION GUIDE eenen en 2 FRONT PANEL AND REAR PANEL DESCRIPTION 2 BATTERY REPLACEMENT AND STORAGE eeen 4 BATTERY REPLACEMENT PROGEDURE 4 TROUBLESHOOTING sns ternensssenamersiennberdetestecnvebndetenenetestbebes udon 6 TECHNICAL SPECIFICATIONS nonnen enen eenen enenneenenenenenee 7 DEFINITION FOR ILLUMINATED LED INDICATORS ne 8 LIMITED WARRANTY naer sveensoservatearenteeetennese dee vad tdnadd daadaa ndana adian 8 Thank you for purchasing a Legacy Power Conversion Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow all installation and operation instructions completely This UPS is designed to provide guaranteed power protection for connected electronic equipment The accompanying SeeUPS2020 software saves data closes open applications and automatically shuts down your computer system in an intelligent and orderly manner Legend SB825 Uninterruptible Power System IMPORTANT SAFETY WARNINGS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries
2. Limited Warranty claim on a Product you must do the following 1 Complete and return the Legacy Warranty Registration Card or provide reasonable proof of purchase for example a sales receipt that establishes you as the Initial Customer the original end user consumer purchaser of the Product and prove that the Product was purchased within three 3 years of the event for which you want to make a claim for warranty service 2 Call Legacy at 608 565 5878 or 800 859 5711 toll free write to Legacy Power Conversion at N9246 Hwy 80 South Suite 7 Necedah WI 54646 or e mail Legacy at ees eet within ten 10 days of the event for which you want to make a claim 3 When you contact Legacy identify the Product the Purchase Date and request Return Materials Authorization RMA information from Legacy 4 Pack and ship the Product to Legacy as instructed in your RMA Show the RMA code on the shipping label or include it with the Product You MUST prepay all shipping costs and you are responsible for packaging and shipment Legacy will inspect and examine the Product within ten 10 days of receipt If the Product is not as warranted Legacy will repair or replace the Product and return it to you at Legacy s expense or if Legacy is unable to or decides not to repair or replace the Product if defective within a reasonable time Legacy will refund to you the full purchase price you paid for the Product purchase receipt showing price pa
3. Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate CAUTION The UPS must be connected to an AC power outlet with fuse or circuit breaker protection DO NOT plug the machine into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect operation or safety of any life support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery No user serviceable parts inside except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensa
4. the Product will be free from defects in material and workmanship for three years from the date of original purchase subject to the terms of this Limited Warranty This Limited Warranty gives you specific rights and you may have other rights which vary from State to State or Province to Province Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose if applicable to the Product is limited in duration to the period of ownership by the Initial Customer This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product NOTE Some States and Provinces do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty Exclusive Remedies Under Limited Warranty Your exclusive remedy and Legacys sole obligations are as follows for the Product If a the Legacy Product you purchased and still own is defective in material or workmanship under this Limited Warranty or any applicable warranty imposed by law and b all Limited Warranty requirements have been met Legacy will repair or replace the Product if it proves to be defective in material or workmanship during the Warranty Period 9 LEGACY Making a Limited Warranty Claim To make a
5. RY REPLACEMENT AND STORAGE Contact your dealer or call the number in this manual for information on battery replacement The order numbers for the battery are as follows BAT SB825 for SB825 CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel knowledgeable of batteries and their precautions Keep unauthorized personnel away from batteries CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present the risk of electrical shock Do not dispose of batteries in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 DO NOT lay tools or other metal parts on top of battery or any battery terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation a
6. SHOOTING Problem Possible Cause Solution The UPS does Batteries are not fully charged Recharge the battery by leaving the expected runtime Battery s capacity diminishes over Contact Legacy Power Conversion time and use about replacement batteries at service lpc ups com or 800 859 5711 The UPS will not The on off switch is designed to Turn the UPS off Wait 10 seconds and turn on prevent damage by rapidly turning then turn the UPS on it off and on The unit is not connected to an AC The unit must be connected to a outlet 110 120v 60Hz outlet The battery is worn out Contact Legacy Power Conversion about replacement batteries at service lpc ups com or 800 859 5711 Mechanical problem Contact Legacy Power Conversion about replacement batteries at service lpc ups com or 800 859 5711 Outlets do not Circuit breaker is tripped due to Turn the UPS off and unplug at least provide power to overload one piece of equipment Wait 10 equipment seconds reset the circuit breaker and then turn the UPS on Batteries are discharged Allow the unit to recharge for at least 4 hours Unit has been damaged by a Contact Legacy Power Conversion surge or spike about replacement batteries at service lpc ups com or 800 859 5711 Connect the serial cable to the UPS unit and an open serial port of your computer You must use the cable that came with the unit SeeUPS2020 U aa EIS CONNEEEID Try another serial port of
7. UPS is providing battery power p to the Battery Power Supplied outlets on off On i Utility Failure The UPS is providing battery power The rapid beeps indicate the battery will run out of charge within a few minutes Overload Occurs in the Full time Surge Protection Outlets Turn the UPS off and unplug at least one Off Off On Up piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on Overload Occurs in the Battery power Supplied Outlets Turn the UPS off and unplug at least one Off On Off On Off piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on Electrical Wiring Fault This indicates a wiring a problem such as a bad ground missed ground or reversed wiring within the AC outlet User is omar On Ononi Set Up None advised to disconnect all electrical equipment from the outlet and have the outlet checked by an electrician Legend SB825 Uninterruptible Power System LIMITED WARRANTY In purchasing SB825 in the United States or Canada the original end user receives a Limited Warranty from Legacy Power Conversion Inc for ease of reading referred to as Legacy The Limited Warranty is intended to be the original end user s exclusive rights and remedies Limited Warranty The original end user referred to as the Initial Customer receives an express limited warranty referred to as the Limited Warranty for the SB825 purchased f
8. er button to turn the UPS ON or OFF Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing clean power free of surges and spikes Using Battery Indicator This illuminates during utility failure indicating that the battery is USING supplying power to the battery power supplied outlets Battery Backup and Surge Protection Outlets B Provides three battery powered and surge protected outlets for ma connected equipment to insure temporary uninterrupted operation BT during a power failure and protection against surges and spikes Surge Protection Outlets Provides three surge protected only outlets for connected equipment a Circuit Breaker Reset for Overload Protection Resetable circuit breakers provide optimal overload protection When an overload occurs the circuit breaker will pop and the UPS will switch to battery back up mode Unplug at least one item from the UPS and press the circuit breaker in to reset it Serial Port to PC This port allows connection and communication from the DB 9 serial or USB port on the computer to the UPS unit The UPS communicates its status to the SeeUPS2020 software This interface is also compatible with the UPS service provided by Windows NT Windows 2000 and Windows XP RESET Network Protection Ports RJ45 RJ11 U These ports protect standard network cables and telephone cables B er BATTE
9. id is required CONDITIONS TO THE LIMITED WARRANTY The Limited Warranty is the only and the exclusive express warranty of Legacy with respect to the Product This exclusion of other express warranties applies to written and oral express warranties LIMITATION THE LIMITED WARRANTY DOES NOT COVER The Limited Warranty is intended to exclusive rights and remedies and replace any other rights to the extent allowed by law As to the Legacy Product the limited warranty does not cover or apply to misuse modification operation or storage outside environmental limits for the Products in transit in shipment or in storage damage or deterioration improper operation or maintenance or use with items or equipment not designed or intended for use with the product The Limited Warranty Does Not Apply Unless The Initial Customer 1 Has properly connected the Product and the Connected Equipment to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code ANS NFPA 70 without the use of any adapters extension cords of other connectors 2 Has provided a suitable and proper environment for use and installation of the Product and Connected Equipment 3 Has properly installed and operated the Legacy Product and Connected equipment 4 Has operated the Product at all times within the limitations on the Product s VA capacity as stated in this User Manual Legend SB825 Uninter
10. mits and also to prevent interference to the nearby radio and television reception Itis essential that only the supplied power cord be used Use only shielded cables to connect I O devices to this equipment CAUTION Any changes or modifications not expressly approved by the guarantee of this device could void the user s authority to operate the equipment lB sac For more information contact us at Legacy Power Conversion Inc N9246 Hwy 80 South Suite 7 Necedah WI 54646 Tel 800 859 5877 Fax 608 565 5879 Email sales lpc ups com Web www lpc ups com Entire contents copyright 2006 Legacy Power Conversion Inc All rights reserved Reproduction in whole or in part without permission is prohibited 12
11. nd maintenance applicable to a UPS and a remote battery supply not having a grounded circuit BATTERY REPLACEMENT PROCEDURE 1 Turn off and unplug all connected equipment 2 Turn the UPS off and unplug it from the AC power source 3 Turn the UPS upside down 4 Remove the 4 retaining screws and remove the cover Legend SB825 Uninterruptible Power System 5 Remove the battery from the compartment 6 Disconnect the battery wires from the battery 7 Install the replacement battery by connecting the red wire to the positive terminal of the battery and connecting the black wire to the negative terminal of the battery 8 Slide the battery back into the compartment 9 Replace the cover and the 4 retaining screws 10 Recharge the unit for 4 8 hours to ensure the UPS performs expected runtime REMINDER Batteries are considered HAZARDOUS WASTE and must be disposed of properly Contact your local government for more information about proper disposal and recycling of batteries STORAGE First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected to the UPS to avoid battery drain To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to insure battery life If the battery remains uncharged for an extended period of time it may suffer permanent loss of capacity LEGACY TROUBLE
12. rom Legacy referred to as the Product The Limited Warranty is for the Product itself The Limited Warranty is subject to the terms set forth below Additionally State or Provincial law may adjust the terms of the Limited Warranty or the State or Province may impose additional obligations or additional implied warranties To the extent necessary to comply with those laws the terms of the Limited Warranty should be read to adjust to those requirements only to the extent necessary to comply with such local law If you are an Initial Customer you are asked to read the following terms and conditions carefully before using the Product By using the Product you consent to be bound by and become a party to the Limited Warranty If you do not agree to the terms and conditions of the Limited Warranty you should return the Product for a full refund prior to using it REGISTRATION Legacy requests that you complete and return the Warranty Registration Card enclosed with the Product or register the Product at its website www lpc ups com to establish that you are the Initial Customer of the Product and therefore entitled coverage under the Limited Warranty Registration is not required for Limited Warranty coverage but note if you do not complete a registration card you will be required to provide proof of purchase as described below to have the benefits of this Limited Warranty LIMITED WARRANTY Legacy warrants to you the Initial Purchaser that
13. ruptible Power System Legacy Does Not Cover or Undertake Any Liability in Any Event for Any of the Following 1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or Surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10T Ethernet lines when properly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or Therefore transmission or fluctuations or by transients in such transmission 3 ee from any circumstance described as excluded above with respect to the product 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the product or the Connected Equipment Exclusion of Consequential and Other Damages The sole and exclusive remedies of the Initial Customer are those provided by the Limited Warranty Legacy excludes any liability for personal injury under the Limited Warranty Legacy excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property loss of profits business interruption loss of information or data This exclusion applies e
14. th Necedah WI 54646 and its phone number is 608 565 5878 or 800 859 5711 toll free Legacy is the warrantor under this Limited Warranty You may also contact Legacy on the Internet at www lpc ups com E LEGACY FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for compliance must be specified in the instruction CAUTION A shielded type power cord is required in order to meet FCC emission li
15. tion from the aquarium can come in contact with metal current contacts and cause the machine to short out LEGACY UNPACKING Inspect the UPS upon receipt The box should contain the following 1 UPS Unit 1 SeeUPS2020 Software Disk 1 Serial Interface Cable DB 9 1 Telephone Cable 1 User s Manual 1 Warranty Registration Card HARDWARE INSTALLATION GUIDE 1 Connect the equipments to your UPS outlets Items such as copiers laser printers vacuums space heaters or other large electrical devices should not be connected to the UPS The power demand of your connected equipment cannot exceed the maximum total power rating of your UPS 2 Connect your UPS power cord into a two pole three wire grounding receptacle only Please avoid using extension cords and adapter plugs To maintain optimal battery charge leave the UPS EO plugged in at all times JP PLUG IN 3 Press the UPS power button to turn it on The Power On indicator will be illuminated Green 4 Install your optional software and accessories To use the software simply connect the enclosed serial interface cable to the serial port on the UPS and an open serial port on the computer BASIC OPERATION FRONT PANEL AND REAR PANEL DESCRIPTION usin eTe Legend SB825 Uninterruptible Power System Power Button D Press the pow
16. ven though damage or loss is caused by negligence or other fault NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES Legacy does not sell the Products for use in high risk activities The Product is not designed or intended for use in hazardous environments requiring fail safe performance including the operation of nuclear facilities aircraft navigation or communication systems air traffic control weapons systems life support or medical applications or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of life support device collectively High Risk Activities Legacy expressly disclaims any express or implied warranty of fitness for High Risk Activities Legacy does not authorize use of any of its products use in any High Risk Activities ANY SUCH USE IS IMPROPER AND IS A MISUSE OF LEGACY PRODUCTS The Limited Warranty is governed by the laws of the United States and the State of Wisconsin without reference to conflict of law principles The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded Contact Information Legacy s address is N9246 Hwy 80 Sou
17. your computer wor the wrong port is inactive all icons are gray The unit is not providing battery power The serial cable is not connected Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS on This should reset the unit The serial cable is not the cable You must use the cable included with that was provided with the unit the unit for the software Legend SB825 Uninterruptible Power System TECHNICAL SPECIFICATIONS Capacity VA Capacity Watts Input Voltage Range 100Vac 140Vac Frequency Range On Battery Output Voltage On Battery Output Frequency Transfer Time Typical Overload Protection On Utility Circuit Breaker On Battery Internal Current Limiting Surge Protection and Filtering Lightning Surge Protection Internet Ready DSL Phone RJ11 RJ45 One In One Out FAX Modem Protection One In One Out Physical Total of UPS Receptacles Maximum Dimensions 28 3cm x 9 1cm x 16 4cm Weight 7 5kg Battery Sealed Maintenance Free Lead 12V 9AH x 1 Acid Battery User Replaceable Yes Hot Swappable Battery Pack Typical Recharge Time Warning Diagnostics Indicators Power On Using Battery Wiring Fault Audible Alarms On Battery Low Battery Overload SeeUPS2020 Software LEGACY DEFINITIONS FOR ILLUMINATED LED INDICATORS E A sul Condition Power Wiring Using Circuit On Fault Battery Breaker Alarm n Off Off Off On Off On Utility Failure The