Home
EXgarde Texecom Integration User Manual
Contents
1. Events gt Name Elite 48 Information Long Name Comment Options Model Elite 48 v IPAddress Port 10 0 1 2893 10001 UserName Password Figure 7 Add New Panel NOTE The SDK must be running prior to the panel being added If the SDK isn t running then the panel zones and other status information will not be created correctly Once the panel has been added then the SDK will interrogate the panel to get the zone area and system information and populate the database accordingly Once the panel has been added the SDK will interrogate the panel for any new events and any changes in status every 10 seconds EXgarde Texecom Integration User Manual Copyright 2011 Last Change 11 August 2015 4 3 Last Change 11 August 2015 Installation Configure Arm Disarm Readers If you wish to use access control readers to arm and disarm the intruder panel then you need to configure these Configuration of the readers is via the IntreuderConfiguration application which is located in C Program Files x86 TDSi Exgarde SDK Runtime Intruder directory Configure Readers When you run the application enter the default user name and password of the SDK user and click the connect button This will then display the configured intruder panels and readers on the system f a Intruder Reader Configuration m ole jes Database User Operator Name sdkuser Passw
2. Copyright O 2011 11 August 2015 Page 3 Functionality 3 3 System Status This provides an indication of the status of the intruder system by displaying the state of each of the internal system flags along with the status of that flag FagNo Panel Description On 8 Elite 48 ATS Path Fault 0 Om 9 Elite 48 Mains Power Off 0 OD 10 Elite 48 Auxiliary Fuse Blown 0 On 11 Elite 48 Bell Tamper 0 On 12 Elite 48 Auxiliary Tamper 0 On 13 Elite 48 Panel Lid Tamper 0 On 14 Elite 48 Engineer Working 0 Figure 3 System Status 34 Partition Area Status This provides an indication of the status of each of the partitions areas of the intruder panel New Bce XK Delete 2 Properties 3 Events Zones Flags Partitions 0 Ready Force Armable Bell SCH Detector reset ON 1 Elite 48 Ready Force Armable Bell SCB Detector reset Oe 2 Elite 48 Ready Force Armable Bell SCB Detector reset on 3 Elite 48 Ready Force Armable Bell SCB Detector reset Figure 4 Area Status 3 5 Arm Disarm from Access Software The intruder panel can be armed and disarmed by the operator from within EXgarde Disarm Intruder Panel Q Show events Show Alarms bk Instant Report Date Time mm Figure 5 Arm Disarm Panel O NOTE This will only perform a full Arm or Disarm d CAUTION IF THERE ARE ERRORS ON THE PANEL THEN YOU WILL NOT BE NOTIFIED WHEN PERFORMING A SET USI
3. use of this product Contents 1 o O iaaa dadadada sadida adsis 1 LL A aed ade 12 einen E EE 1 3 Op ratiOM ii a 2 KA Oe E E e 3 apes nario 3 31L Intruder c cmm 3 32 EME de T T M 3 SINE C eu ere E eee 4 3 4 Partition Area nt E 4 3 5 Arm Disarm from Access Software EENEG 4 35 e EXBITES aoa AR ROS RU I RU U UE MU dA SH tae een aces 5 4 Configuration EE 6 4 1 Configure Texecom EE eegener 6 42 ADO Panel WO TEEN 7 43 Configure Arm Disarm Readers cininvinnaore nai ii 9 5 APP 11 SL Mide COMMS UT e TINE rr A n E EXgarde Texecom Integration User Manual Last Change Copyright 2011 11 August 2015 Page i Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 SA 3 LOMO E 3 SA EE CT A NT VIE A Arw Disarm Panel cui TELLE TE 4 Intruder Panel Summary EE 7 Add NOW E RM 8 Configure Arm Disarm Reade Socera 9 Completed Arm Disarm Copfteuratlon cecsecsssessssssesssesssesssesssesssesssesssesssesssesssessscsssessscsssesssesssesssesseessees 10 Document Control Issue Date Issued Change Detail Issued by 1 14 01 13 Initial Release MPS 2 16 10 13 Supported panels added MPS 3 06 07 15 Arm Disarm reader requirements added GFH 4 11 08 15 Title change GFH EXgarde Texecom Integration User Manual Copyright O 2011 Last Change Page ii 11 August 2015 y g emere 1 Summary 1 1
4. NG THIS METHOD EXgarde Texecom Integration User Manual Copyright O 2011 Last Change Page 4 11 August 2015 3 6 gt E e e Last Change 11 August 2015 Functionality Arm Disarm from Access Events The intruder panel can also be configured to automatically arm or disarm based upon Access Granted events This can be configured such that a certain number of Access Granted events must occur within a given time period in order to arm disarm the panel NOTE This will only perform a full arm or disarm Arming and disarming of zones part set is not supported NOTE In order to arm and disarm the intruder panel separate IN and OUT readers will be required CAUTION IF THERE ARE ERRORS ON THE PANEL THEN YOU WILL NOT BE NOTIFIED WHEN PERFORMING A SET USING THIS METHOD CAUTION IF YOUR SYSTEM IS MONITORED WITH A URN THEN THIS PROCESS OF ARMING DISARMING THE PANEL IS NOT ALLOWED UNDER THE REGULATIONS EXgarde Texecom Integration User Manual Copyright O 2011 Page 5 g peer 4 Configuration Page 6 4 1 Configure Texecom Panel Once the IP address has been configured on the COM IP module it should be set to Nothing within the Elite panel NOTE If you have set the Com1 option to be Com IP then ensure that this is configured to Nothing Then configure the COM IP module by opening a command prompt Telnet to the panel by entering telnet x x x x 9999 and enteri
5. Purpose This document defines how to configure and set up Intruder Integration between the EXgarde Access Control Software and the Texecom Premier Elite range of panels 1 2 Supported Models Only the Texecom Premier and Texecom Premier Elite range of panels is supported The panels must also have the COM IP module fitted The minimum supported firmware versions are Tested panels Elite 24 48 88 168 V 2 04 Elite 640 Untested panels Premier 412 V9 0 Premier 816 V9 0 Premier 832 V2 0 Premier 48 V7 5 Premier 88 V7 5 Premier 168 V7 5 Premier 640 V8 0 O NOTE This document will be updated as the other panels are tested 1 3 Operation The intruder panel communicates with the EXgarde SDK via a TCP IP interface The communication is two way and uses the intruder panel protocol O NOTE In order for the integration to work you need the EXgarde SDK installed and configured prior to configuring the intruder panel O NOTE You will need to ensure that you have the integration and intruder licenses for EXgarde EXgarde Texecom Integration User Manual Last Change Copyright O 2011 11 August 2015 Page 1 L g ege 2 System Requirements The following pre requisites must be satisfied prior to installing the SDK Operating System Windows or higher lIS60r higher Microsoft Net 4 or higher CPU Pentium or higher Development environ
6. exgar de Texecom Integration User Manual UM0077 GB Issue 4 11 08 2015 www tdsi co uk TDSi Unit 10 Concept Park Innovation Close Poole Dorset BH12 4QT UK Tel 444 0 1202 723535 Fax 44 0 1202 724975 Sales Enquiries sales tdsi co uk Marketing Support marketing tdsi co uk Technical Support support tdsi co uk ACCESS EVERYWHERE Foreword 2011 TDSi Ltd All rights reserved Time and Data Systems International Ltd operate a policy of continuous improvement and reserves the right to change specifications colours or prices of any of its products without prior notice Guarantee For terms of guarantee please contact your supplier Trademarks Copyright O 2011 Time and Data Systems International Ltd TDSi This document or any software supplied with it may not be used for any purpose other than that for which it is supplied nor shall any part of it be reproduced without the prior written consent of TDSi Microsoft and Windows are registered trademarks of Microsoft Corporation All other brands and product names are trademarks or registered trademarks of their respective owners Cautions and Notes The following symbols are used in this guide CAUTION This indicates an important operating instruction that should be followed to avoid any potential damage to hardware or property loss of data or personal injury NOTE This indicates important information to help you make the best
7. iguration When you are complete click the Save Configuration This will save the information in the IntruderConfig xml configuration file which is located in the Runtime Service directory See Appendix for details of the file structure EXgarde Texecom Integration User Manual Copyright O 201 1 Last Change Page 10 11 August 2015 L g access redd 5 Appendix 5 1 Intruder configuration file The configuration file is in XML format and consists of the following elements Panelld Id of intruder panel in EXgarde database nReader id id and name of reader to use to disarm panel OutReader id id and name of reader to use to arm panel Taps Number of taps and time lt xml version 1 0 encoding UTF 8 gt lt Configuration gt lt Panel id 559 gt lt InReaders gt lt InReader id 1650 name Reader1 gt lt InReaders gt lt OutReaders gt lt OutReader id 1651 name Reader2 gt lt OutReaders gt lt Taps WithinSeconds 5 NumberRequired 2 gt lt Panel gt lt Panel id 579 gt lt InReaders gt lt InReader id 1650 name Reader1 gt lt InReaders gt lt OutReaders gt lt OutReader id 1651 name Reader2 gt lt OutReaders gt Taps WithinSeconds 5 NumberRequired 2 gt lt Panel gt lt Configuration gt EXgarde Texecom Integration User Manual Last Change Copyright 2011 11 August 2015 Page 11 Time and Data Systems International Ltd Unit 10 Conce
8. ment Microsoft Visual Studio 2010 or higher x EXgarde Texecom Integration User Manual Copyright O 201 1 Last Change Page 2 11 August 2015 ACCESS EVERYWHERE 3 Functionality 3 1 Intruder Events The integration allows the EXgarde Access Control software to receive and display all intruder events in the event log This allows the security operators to see any alarms or events raised by the intruder panel without having to log in to the intruder panel and use the keypad EH SS Details Go Stop Pri gres From 11 01 2013 09 27 To 1170172013 0827 gt All Events Date Time Event Source Detail 1 Detail 2 Detail 3 2 11 01 2013 09 27 Operator Update Operator Admin Admin 14 12 2012 12 00 Low Battery Alarm Elite 48 0 1 Alarm 14 12 2012 12 00 Site Data Changed Elite 48 0 1 Alarm 114 12 2012 12 06 Zone Tamper Elite 48 1 1 Alarm 14 12 2012 12 06 User Code Entered Elite 48 1 1 Restore Figure 1 Intruder Events 3 2 Zone Status The status of all of the zones configured within the intruder panel can be viewed by the operator This provides a quick way of checking the status of various devices On 1 Elite 48 1 3 Latched Alarm On 2 Elite 48 4 1 Healthy O 3 Elite 48 3 1 Healthy Oe 4 Elite 48 3 1 Healthy On 5 Elite 48 3 1 Healthy OG 6 Elite 48 3 1 Healthy Ll 7 Elite 48 3 1 Healthy OA 8 Elite 48 3 3 Healthw Figure 2 Zone Status EXgarde Texecom Integration User Manual Last Change
9. ng the Texecom password NOTE You will need to contact your Texecom dealer or Texecom directly to obtain the password TDSi cannot and will not supply this Select option 0 to set up the IP address and netmask if you have not already done so Select option 1 Channel 1 Ensure the following are changed if not already set Baudrate 19200 I F Mode CC Send in Modem Mode is set to N Accept all other defaults Select 9 to save and exit EXgarde Texecom Integration User Manual Copyright O 201 1 Last Change 11 August 2015 Installation 4 2 Add Panel to EXgarde Select the Equipment tab and Summary Display and then Intruder Panels Ey Outline Summary e Computers 2 Portals O ACUs n Doors X Readers lt CCTV Controllers View points Biometric Read ECH P O Inputs J Counters Bf Inconsistency C3 Intruder Panels Active Tenant Landlord e Keyholders e Equipment Figure 6 Intruder Panel Summary Then when the window appears 1 Select the new Intruder Panel from the right hand side 2 Enter the Name for the panel 3 Select the panel type from the Model drop down list 4 Enter the IP address note the port number should be 10001 O NOTE The UserName and Password fields are not used at present EXgarde Texecom Integration User Manual Last Change Copyright O 2011 11 August 2015 Page 7 Installation Page 8 X Delete 7 Properties
10. ord 777 Name Admin Disconnect Intruder Panels Reader Configuration Select Intruder Panel Select Readers Entry Readers in Reader d Out Reader Reader 1 Rodri ada Exit Readers Number oftaps 0 Within seconds 0 Save Configuration Connected Figure 8 Configure Arm Disarm Readers First of all select the intruder panel you want to configure Then select the reader you will use as an entry reader this will disarm the panel and click the add button alongside the Entry Readers box Repeat the same process for the Exit readers used to arm the system EXgarde Texecom Integration User Manual Copyright O 2011 Page 9 Installation Configure presentation method To configure how many times you need to present your card enter a value into the Number of taps To configure the duration in which the number of presentations should be made enter a time in seconds in the Within Seconds box The figure below uses the In Reader to Disarm the system the Out reader to Arm the system and the card needs to be presented twice within 5 seconds P ud Intruder Reader Configuration ollel z Database User Operator Name sdkuser Password 77777 Name Admin Intruder Panels Reader Configuration Select Intruder Panel Select Readers Entry Readers In Reader Reader 1 Reader 2 ESE SES Number oftaps 2 Within seconds 5 Save Configuration Connected Figure 9 Completed Arm Disarm Conf
11. pt Park Innovation Close Poole Dorset BH12 4QT UK t 44 0 1202 723535 f 44 0 1202 724975 w http www tdsi co uk Sales Enquiries mailto sales tdsi co uk Marketing Support marketing tdsi co uk Technical Support mailto support tdsi co uk