Home
Contents - Adrenalicia
Contents
1. e Push the navigation button up to highlight the Parameters menu e From the Parameters menu select the De Bounce feature by pushing the navigation button inwards e Scroll up or down through the De Bounce settings by pushing the navigation button up or down e Once the desired setting is reached press the navigation button inwards to save the new setting A Saved De Bounce message will be displayed The Parameters menu will be displayed This allows you to select the correct ANGEL eye settings for the type of paint that you are using Once you have selected the correct setting the ANGEL eyes program will intelligently adjust itself to the fragility of your paint 1 6 Fragile 7 10 Medium 11 12 Hard e Ensure that your loader is at its maximum performance and reliability otherwise you may encounter problems related to the loader e Selection of a paint type setting that is too high may result in ball breakages e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highlight the Parameters menu e Push the navigation button in to select the Parameters menu e From the Parameters menu select the Paint Type feature by pushing the navigation button inwards e Scroll up or down through the Paint Type settings by pushing the
2. Breakout and Ramp settings do not function in this Mode This is a dry firing mode for firing the ANGEL when on display and is designed to demonstrate the rate of fire achievable It should only be used for demonstration ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE The ANGEL s default values are Mode semi Soft breakout settings seconds 10 Hard breakout settings seconds 10 Soft ramp settings start delay shots 4 Kick in BPS 5 Drop out BPS 4 Hard ramp settings start delay shots 4 Kick in BPS 5 Drop out BPS 4 Dwell time m secs 9 MROF eyes ON limit unlimited MROF eyes OFF limit 15bps De Bounce level 10 Paint Type 8 Shot Filter ABS Anti bolt stick m secs ANGEL eyes Game time set mins Secs Alarm time set mins secs ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that
3. INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE RUBBER FINGER DETENT REPLACEMENT The ANGEL FLY incorporates the new 3 piece eye cover strap This eye cover strap incorporates the improved ADB fingers and is designed for ease of replacement of the ADBs and trouble free cleaning of the ANGEL eyes if required El Remove the volume chamber maintenance plug with a 4mm Allen wrench PA Slide the front section of the eye cover forward and remove 3 Carefully remove the eye cover arms from either side of the ANGEL 4 Using a 2mm Allen wrench or similar push out the ADB finger to be replaced Ai Take a new ADB finger and insert the grommet into the retaining hole of the eye cover arm Repeat this process for the other side To reassemble reverse the above procedure Note It is important that the front section of the eye cover is located correctly on the eye cover arms as shown in fj KA Also note that it is important not to splay the eye cover arms too far apart This may result in damag
4. A WARNING ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE TRIGGER REMOVAL Firstly remove the grip frame see page 21 figs 1 4 Then E With the grip frame removed you now have access to the trigger clamp plate and the A Remove the trigger clamp plate EJ Remove the trigger Trigger clamp plate Locate onto trigger bearings A WARNING USEFUL CONVERSIONS Listed are some useful conversions relating to pressure velocity mass and distance PRESSURE 1 aim 101 325 bar 1 atm 14 6959 psi 1 bar 14 5038 psi 1 psi 0 0689476 bar VELOCITY 1 Ft s 0 3048 m s 1 Ft s 0 6818180 Mph 1 m s 3 28084 Ft s 1 m s 2 23694 Mph 1 m s 3 6 Kph MASS 1g 0 05274 oz 1 Kg 2 20462 Ib 1 oz 0 0283495 Kg DISTANCE 1 mm 0 0393701 Inch 1 Inch 25 4mm 1 thou 25 4 micron 1 micron 0 0393701 thou FORMULA TO CONVERT FEET PER SECOND Ft s TO FOOT Lbs Force 1 foot lbs force 1 35582 Joules 1 Joule 0 737562
5. breech area of the ANGEL whilst the ANGEL is switched on and able to fire e Never put your finger or any foreign objects into the breech or paintball feed tube of the ANGEL e Never allow pressurised gas to come into contact with any part of your body e Always switch off the ANGEL when not in use e Always fit a barrel blocking device to your ANGEL when not in use on the field of play e Always remove all paintballs from the ANGEL when not in use on the field of play e Always remove the first stage regulator and relieve all residual gas pressure from the ANGEL before disassembly e The ANGEL can hold a small residual charge of gas typically 2 shots with the first stage regulator removed Always discharge the ANGEL in a safe direction to relieve this residual gas pressure e Always remove first stage regulator and all residual gas pressure from the ANGEL for transport and storage e Always follow warnings and guidelines given with your first stage regulator for safe transport and storage e Always store the ANGEL in a secure place e THIS OPERATOR S MANUAL MUST ALWAYS ACCOMPANY THE PRODUCT IN THE EVENT OF RESALE OR NEW OWNERSHIP e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE A WARNING ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e ANGEL is LIVE and capable of firing e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is remo
6. ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE The navigation button is located on the rear of the grip frame and allows access to the internal menu option Push the button up or down and hold for 2 seconds To navigate through the options simply push the button up to scroll up and push the button down to scroll down Press the button inwards to make a selection IMPORTANT NOTE When accessing the status menu from the LIVE screen the ANGEL will remain LIVE and any trigger pull will return you to the LIVE screen If accessing any of the other menus from the status menu the ANGEL will revert to SAFE and any trigger pull will return you to the SAFE screen A WARNING ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE IMPORTANT NOTE Tournament lock
7. foot Ibs force 1 Gram 15 4324 Grains 1 Grain 0 000142857 Ib 1 lb 7000 Grains Velocity squared x Projectile weight VELOCITY Ft s feet per second PROJECTILE WEIGHT GRAINS Therefore a paintball 3 2grams 300Ft s 9 9 foot Ibs ftlbs ANGEL PROBLEM SOLUTION PAGE ANGEL WILL NOT FIRE No air or nitrogen present Propellant Air Nitrogen Supply 6 ls the battery operational Change the battery 4 Is the ANGEL in SAFE Making the ANGEL LIVE 3 ls the trigger not closing the button Trigger Adjustment 24 ls the trigger not releasing the button Trigger Adjustment 24 Is the bolt jammed forward Clear the blockage from breech T Is the LPR set correctly LPR Adjustment 20 Is the OPTO Trigger functioning Trigger Adjustment 24 Are the ANGEL Eyes switched on Ensure paint is present Are the ANGEL Eyes optics blocked Clean the ANGEL Eyes Optics VELOCITY VARIATIONS Are good quality paintballs being used Use good paintballs ls the barrel bore correct for the paint Use suitable barrel Is the paint swollen cold or hot Review your storage of paint Is the barrel bore clean Clean the barrel Is the tank reg choking on gas supply Check tank regulator assembly Is the tank reg operating correctly Check tank regulator assembly Is the minireg operating correctly Minireg Service 16 Is th
8. is shown in EE and can be easily accessed by removing the exhaust valve stem assembl following the instructions in points JJ and below Once removed inspect the face seal If the face of this seal is scored or impregnated with grit or dirt or is excessively deformed it is necessary to replace the exhaust valve stem assembly by reversing the procedure in points J and H below E Remove the volume chamber maintenance plug using a 4mm Allen wrench 2 Insert a suitable Allen wrench into the cavity The exhaust valve stem which is magnetic will be attracted to the Allen wrench and can be easily removed EXHAUST VALVE GUIDE REMOVAL Once the valve stem assembly has been replaced if you are still experiencing the same problem you will need to inspect the O ring on the exhaust valve guide nearest the face seal for nicks or tears and replace if necessary If there are no signs of damage to this O ring inspect the face seal seat for dents or scratches and replace if necessary following the instructions in points JJ and above and points EJ to EI below E Slide off the eye cover 4 Remove the fore grip as shown on page 16 Fl Remove the end plug retention pin using the extraction tool provided g Carefully move eyes out of the way to avoid damage Remove the end plug 8 Remove the two screws retaining the grip frame using a 2mm Allen wrench A WARNING ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS A
9. to the company s standard terms and conditions of sale a copy of which is available on request ANGEL patents applied for design rights and all rights reserved The ANGEL is marketed and distributed by WDP Ltd Company registered in England No 2114341 and WDP Paintball Inc registered in USA No 2479769 No warranty is given to parts not manufactured by the manufacture r and all liability for loss damage or injury is excluded This warranty must be construed and read in conjunction with the product s terms and conditions of sale To make a warranty claim the purchaser must first contact the nearest authorised ANGEL Service Centre for instructions A list of authorised ANGEL Service Centres may be obtained through the WDP website www wdp tv or by contacting WDP by mail at WDP Metro Triangle 221 Mount Street Nechells Birmingham England B7 5QT or by fax at 44 0 121 327 3967 or by calling 44 0 121 328 2228 TERMS OF WARRANTY USA CANADA 1 General Express Warranties WDP warrants to the buyer who is purchasing to place into use Buyer only that the ANGEL Product shall be free from material manufacturing defects in materials and workmanship for six months from the date of purchase subject to the requirements disclaimers and limitations of this Warranty This is not a Warranty of performance but a limited Warranty as to the condition of the Product at the beginning of the Warranty perio
10. 000 shots for ANGELs that are used regularly or in cases of prolonged spells of infrequent use prior to each occasion you use your ANGEL Internal greasing of your ANGEL is required after disassembly to avoid damage to internal parts during re assembly The only grease suitable for this purpose is ANGEL Love Juice Extreme Grease For full details on oiling or greasing the ANGELs internal parts please go to http wdp tv e_blast07 140507 news may0 7 news html lube e When inserting screws into the bottom of the grip frame the screw thread length must not exceed 0 375 10mm otherwise damage will occur to the electronics e We recommend that you remove the righthand cheek cover and battery when inserting these screws and ensure that the screws do not project into the circuit board cavity when fitting e The ANGEL should never be immersed into water otherwise damage may occur to the electronics READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE MINI REG REMOVAL amp ASSEMBLY The mini regulator is a second stage regulator that is used to control the velocity and regulate the gas pressure It can be deleted but only if a suitable first stage regulator is used that incorporates a high flow and good regulation properties across the tank pressure range E Remove the velocity adjuster screw located on the fore grip using a 3mm Allen wrench E Unscre
11. AR pressure is above 40psi and if so open the the ANGEL Sh 4 Bale a breech block and listen for gas emitting from e Ensure that there are no paintballs L PIE aff i W the breech pin slot If gas is emitting from the in the ANGEL e Ae Wig breech port it is not Ram related and will be an CZS ial 7 T due to your exhaust valve If gas is emitting e Paintball industry standard eye face ear ee i we k from the slot remove your Ram following and head protection designed specifically SS gt ee a A _ the instructions below and inspect the three to stop paintballs and meeting ASTM aa oe A ys lie O rings for damage and replace if necessary standard F1776 USA or CE standard oe Da E a 4 Ii the O rings are not damaged inspect the Europe must be worn by user and any I oes ie i a Ram shaft for scratches or dents and replace person within range the complete Ram if necessary following the instructions below e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE EI Remove the right hand grip cheek by removing the 3 screws using a suitable 2mm Allen wrench 2 Carefully unplug the solenoid from the board Ej Carefully unplug the eye ribbons from the board 4 Remove the two screws retaining the grip frame using a 2mm Allen wrench and remove the grip frame A Turn the breech release knob clockwise and remove the bolt from the breech NOTE the breech will not open unle
12. MENT 7 OLED MENU 8 9 MODES SEMI AUTO 10 NPPL 10 PSP 10 MILLENNIUM 10 XBALL NXL 10 CFOA 10 FULL AUTO 10 DEMO 10 11 CUSTOM SEMI Ti BREAKOUT 11 SOFT BREAKOUT 11 HARD BREAKOUT 11 RAMP ial PARAMETERS VALVE DWELL 11 DE BOUNCE 11 12 PAINT TYPE 12 MROF EYES ON OFF 12 BREAKOUT 12 RAMP 1213 SHOT FILTERING 13 ANTI BOLT STICK 13 SOFTWARE VERSION 13 FACTORY RESET 13 GAME TIMER ALARM 14 TOURNAMENT LOCK 14 GENERAL CARE amp CLEANING 15 MINI REG REMOVAL amp ASSEMBLY 16 RUBBER FINGER DETENT REPLACEMENT 17 ANGEL EYES SENSOR CLEANING 17 EYE RIBBON REMOVAL 18 LPR PRESSURE TEST 19 LPR ADJUSTMENT 20 LPR ASSEMBLY 20 LPR SPOOL REMOVAL 20 LPR REMOVAL 21 EXHAUST VALVE STEM GUIDE REMOVAL 22 RAM REMOVAL 29 TRIGGER ADJUSTMENT amp REMOVAL 24 USEFUL CONVERSIONS 25 FAULT FINDING 25 26 WARRANTY EEC ROW 27 WARRANTY USA CANADA 28 WARRANTY CARD INSIDE BACK COVER IN ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e The ANGEL is not a toy e Careless or improper use including failure to follow instructions and warnings within this Operator Manual and attached to the ANGEL could cause death or serious injury e Do not remove or deface any warnings attached to the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM
13. ND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE 9 Remove the LPR retaining pin ET Using a blunt pick carefully extract the exhaust valve guide as shown Important notes for the re assembly of components e Ensure exhaust valve stem assembly Exhaust valve is located in the exhaust body within guide seal the ANGEL oi e Ensure that the end cap is located correctly READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE A WARN l NG Li T ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY Bea RAM REMOVAL INSTRUCTIONS AND GUIDELINES Tia E Bg You may need to remove your Ram if the e Ensure a barrel blocking device is fitted ne t ae Sa ANGEL s hammer has come loose or the to the ANGEL vi Lek e m A 5 Ram is leaking To establish if a gas leak is l ly el a W coming from the Ram first check your LPR e Ensure the hopper is removed trom f tAn be L
14. NSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE PARAMETERS conr Ramp cont e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highlight the Parameters menu e Push the navigation button in to select the Parameters menu e From the Parameters menu select the Ramp feature by pushing the navigation button inwards e Select Soft or Hard Ramp option using the navigation button by pressing it inwards to confirm the desired option e You can then select to adjust Start Delay Kick in BPS and Drop out BPS by pressing the navigation button inwards A Saved Start Delay Kick in BPS and Drop out BPS message will be displayed The Soft or Hard Ramp menu will be displayed Shot filterine This allows the adjus
15. RY REPLACEMENT EJ Remove the right hand grip cheek by removing the 3 screws using a suitable 2mm Allen wrench El Using a blunt pick or the 2mm Allen wrench carefully prise the battery clear of its terminals Fl Remove the battery Observe the battery polarity as marked on the battery housing terminal and on the battery Always use a good quality fresh battery READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE ANGEL ae SWITCHING ANGEL EYES ON OFF ADHERE STRICTLY TO THESE e Ensure that the ANGEL is on see page 3 AND ALL OTHER SAFETY F e As default the ANGEL eyes will always be sail Liege eid obi Sieis ON whenever the ANGEL is switched ON ANGEL 8 AVE STE Tape a ig b El The ANGEL eyes can be switched off e Ensure a barrel blocking device is fitted on i by pulling and holding the trig
16. To comply with some Tournament rules some of the ANGEL s features are required to be locked down so that they cannot be adjusted on the field of play For more details see page 14 a j ot i Fi re ahs j 3 a Live Safe Semi Auto r Millennium XBall NXL CFOA Full Auto Demo Custom Semi ANGEL STATUS Parameters Valve Dwell Anti Bolt Stick Game Timer Set Alarm Time Set Information Current Settings Soft breakout setting Hard breakout setting Soft ramp setting Hard ramp setting MROF eyes on limit MROF eyes off limit De Bounce level Paint Type Shot filtering Anti Bolt Stick ANGEL eyes on off Alarm time set Total shots fired since reset Battery voltage READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE ny E T _ MODES e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highlight the Parameters menu e Push the navigation button in to select the Parameters menu e From the Parameters menu select the Mode feature by pushing the navigation button inward e Scroll up or down through the Mode options by pushing the navigation button up or down e Once the desired M
17. ULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE A WARNING IMPORTANT NOTES e No solvents or abrasive cleaning products should be used All external and internally accessible moving parts should be lubricated using light synthetic oil only e All threads on the ANGEL except those for the ANGEL accessory mountings at the base of the grip frame are metric e ANGEL accessory mountings use industry standard 10 32 UNF at centres 0 75 20mm GENERAL CARE amp CLEANING The ANGEL is designed for minimum maintenance and requires far less lubrication and greasing of internal parts than other high performance markers For external cleaning of the ANGEL we recommend the use of a water moistened cloth The only oil that is suitable for use in external cleaning is ANGEL Love Juice or other synthetic oil which again should only be applied sparingly using a cloth Never use hydrocarbon based oils such as WD40 Vaseline Duck Oil Plus Gas etc to clean or lubricate the ANGEL as this will damage the internal seals Internal lubrication of the ANGEL can be achieved without disassembly by removing your regulator and simply adding a couple of drops of ANGEL Love Juice oil to your ASA adapter Once this has been done re attach your regulator as per the instructions on page 6 and shoot the ANGEL 10 times This will then disperse the lubricant to all the moving parts of the ANGEL This should be done every 10
18. al ih e This Operator s and User s Manual is in English e t contains important safety guidelines and Instructions e Should you be unsure at any stage or unable to understand the contents within this manual you must seek expert advice e Le mode d emploi est en Anglais e contient des instructions et mesures de s curit importantes e En cas de doute ou s il vous est impossible de comprendre le contenu du monde d emploi demandez conseil a un expert e Este manual de operarios y usarios esta en Ingl s e Contiene importantes normas de seguridad e instrucciones e Si no esta seguro de alg n punto o no entiende los contenidos de este manual debe conultar con un experto e Diese Bedienungs und Benutzeranleitung ist in Englisch e Sie enth lt wichtige herheitsrichtlinien und bestimmungen e Sollten Sie sich in irgendeiner Weise unsicher sein oder den Inhalt dieses Heftes nicht verstehen lassen Sie siche bitte von einem Experten beraten ANGEL CONTENTS GENERAL WARNINGS 2 SWITCHING ON YOUR ANGEL 3 TURNING OFF YOUR ANGEL 3 MAKING YOUR ANGEL SAFE 3 NAVIGATION BUTTON 4 BATTERY REPLACEMENT 4 SWITCHING ANGEL EYES ON OFF 5 OPTO BOARD 5 MACRO LINE HOSE PROPELLANT AIR NITROGEN SUPPLY 6 ADJUSTING REMOVING THE ASA 6 INSTALLING AN AIR NITROGEN SYSTEM 6 BOLT REMOVAL AND ROTOR BREECH 7 VELOCITY ADJUST
19. amage resulting from reliance on them WDP does not warrant that the Product is in compliance with any law or industry standards guidelines or procedures WDP standard terms and conditions of sale also apply if Buyer is a direct purchaser from WDP WDP DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THOSE OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY 3 Remedy and Limitation of WDP liability Defective or non conforming Product or parts thereof discovered and returned to WDP freight prepaid with proof of purchase during the Warranty period shall be repaired or replaced by WDP without any additional charge and shipped to Buyer FOB WDP In lieu of repair or replacement if WDP elects WDP may upon return of such product and making a determination of non conformity or defect keep the product and refund the purchase price paid by Buyer Buyer s remedies shall be limited even in the event of WDP default of its Warranty obligations exclusively to those provided in this Warranty UNDER NO CIRCUMSTANCES SHALL WDP OR ANY SUPPLIER DISTRIBUTOR DEALER OR OTHER PERSON BE LIABLE FOR EXEMPLARY PUNITIVE CONSEQUENTIAL OR INCIDENTAL DAMAGES NOR FOR ANY AMOUNT IN EXCESS OF THE BUYER S PURCHASE PRICE Buyer waives any causes of action or theories of liability including but not limited to those arising under contract tort strict liability Product liability statutes or otherwise except as to those sp
20. c upto a preset maximum MROF set at 15 4 BPS The ANGEL will stop firing as soon as the trigger is released If the user stops firing for more than 1 second the initial 3 shots in semi automatic must be re initiated Breakout and Ramp settings do not function in this Mode The ANGEL eyes will default to on whenever the ANGEL is made live via the navigation button With the eyes activated the ANGEL will only fire when a paintball is present and has been detected by the ANGEL eyes The first 3 shots will be fired in semi automatic On the 4th shot the ANGEL will ramp to a preset MROF set at 15 4 balls per second provided that the user maintains trigger pulls at a rate at 5 balls per second or above If the user stops firing for more than 1 second the initial 3 shots in semi automatic must be re initiated Breakout and Ramp settings do not function in this Mode The ANGEL eyes will default to on whenever the ANGEL is made live via the navigation button With the eyes activated the ANGEL will only fire when a paintball is present and has been detected by the ANGEL eyes The ANGEL will fire at a capped maximum rate of 15 balls per second with the ANGEL eyes activated With the angel eyes deactivated the ANGEL will fire at a capped maximum rate of 15 balls per second It is possible to lower the MROF with both eyes on and eyes off in this mode but you will not be permitted to raise them above the 15 BPS cap
21. d this Warranty is only against such defects and not against any other failures such as but not limited to those due to wear and tear exposure to the elements unusual operating environments misuse negligence accident alteration or repair in any respect which in the judgement of WDP adversely affects the condition or operation of the Product Normal maintenance and perishable items such as seals batteries wiring indicator lamps and exhaust valves are excluded from this limited Warranty against defects This Warranty is not transferable and it may not be waived or expanded except in writing signed by WDP The terms and limitations of this Warranty shall also apply to any additional goods or information which may be distributed by WDP relating to the ANGEL 2 Disclaimer and Limitation of Express and Implied Warranties There are no express Warranties other than those contained in this Warranty Whether or not the Product is to be used exclusively by the Buyer there shall be no third party beneficiaries to this Warranty herein NO WARRANTY IS PROVIDED TO DISTRIBUTORS OR DEALERS EXCEPT AS MAY BE EXPRESSLY PROVIDED IN A SEPARATE AGREEMENT OF SALE All descriptions illustrations of the Product and other information in catalogues brochures and price lists or otherwise provided by WDP or others are intended for general information only WDP is not IN responsible for any errors or omissions therein or for any loss or d
22. e navigation button With the eyes activated the ANGEL will only fire when a paintball is present and has been detected by the ANGEL eyes The first 3 shots will be fired in semi automatic On the 4th shot the ANGEL will ramp to a preset MROF set at 15 4 balls per second provided that the user maintains trigger pulls at a rate of 5 balls per second or above If the user stops firing for more than 1 second the initial 3 shots in semi automatic must be re initiated Breakout and Ramp settings do not function in this Mode The ANGEL eyes will default to on whenever the ANGEL is made live via the navigation button With the eyes activated the ANGEL will only fire when a paintball is present and has been detected by the ANGEL eyes The rate of fire will be capped at 15 shots per second Ramping of shots is allowed once 8 balls per second BPS is achieved the ANGEL may ramp up to 15 BPS only if 8 BPS or greater is maintained Once the trigger is released only 1 additional shot may be discharged Breakout and Ramp settings do not function in this Mode XBall NXL The ANGEL eyes will default to on whenever the ANGEL is made live via the navigation button With the eyes activated the ANGEL will only fire when a paintball is present and has been detected by the ANGEL eyes The first 3 shots will be fired in semi automatic On the 4th shot if the trigger is pulled and held the ANGEL will fire fully automati
23. e ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highlight the Parameters menu e Push the navigation button in to select the Parameters menu e From the Parameters menu select the MROF eyes off feature by pushing the navigation button inwards e Scroll up or down through the MROF eyes off settings by pushing the navigation button up or down e Once the desired setting has been reached press the navigation button inwards to save the new setting A Saved MROF eyes off message will be displayed The Parameters menu will be displayed This allows the user to select between a soft and hard breakout mode Once the hard or soft option has been selected the duration that the breakout will be active for can then be selected The length of the breakout mode duration can be set from 1 to 20 seconds e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highlight the Parameters menu e Push the navigation button in to select the Parameters menu e From the Parameters menu select the Breakout feature by pushing the navigation button inwards e Select Soft or Hard Breakout opti
24. e minireg choking on gas supply Minireg Service 16 Are unsuitable after market parts fitted Use genuine ANGEL parts z Is the bolt worn Replace Bolt 7 Is the LPR set correctly LPR Adjustment 20 Is the valve dwell set correctly Dwell Adjustment 11 ls the first shot low Increase Dwell Time 11 VELOCITY TOO LOW HIGH ls the high pressure reg set correctly Check at gas source 6 ls the velocity adjuster screw set correctly Velocity adjustment T Is the bolt sticking Check rubber finger detents 17 Is the LPR set correctly LPR Adjustment 20 Is the valve dwell set correctly Dwell Adjustment 11 GAS LEAKING From the back cover Check solenoid valve 21 figs 6 10 From the Ram assembly Check Ram body O rings 23 From the gas joints Check all fittings From the exhaust valve Exhaust valve stem guide 22 READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE 26 1 lt yi ANGEL PROBLEM SOLUTION PAGE BREAKING PAINTBALLS ls the paint too fragile Use less fragile paint z ls the barrel bore correct for the paint Use a suitable barrel Is the paint swollen cold or hot Review your storage of paint Are the ANGEL Eyes switched on Switch ANGEL Eyes on 5 Are the ANGEL Eyes functioning ANGEL Eyes Test 5 17 ls the loader battery weak dead Replace batterie
25. e to the eye cover ANGEL EYES SENSOR CLEANING Carefully remove the eye cover arms as shown in point EJ above Carefully extract the eye sensor from its housing and gently remove any grease or debris build up using a clean cotton bud Eq READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE W EYE RIBBON REMOVAL 1 Remove the eye cover as shown on page 17 A Remove the fore grip as shown on page 16 EJ Remove the right hand grip cheek by removing the 3 screws using a suitable 2mm Allen wrench 4 Carefully unplug the solenoid from the board Ai Carefully unplug the eye ribbons from the board Al Remove the two screws retaining the grip frame using a 2mm Allen wrench and remove the grip frame Carefully remove the eye ribbon from the ribbon recess To rebuild reverse this procedure ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Always remove the first stage regulator and release all residual gas pressure from the ANGEL before disassembly e The ANGEL can hold a small residual gas charge typically two shots with the first stage regulator removed Always discharge the ANGEL in a safe direction to relieve this residual
26. eakout mode has been initiated or the time period of the breakout elapses the breakout mode will revert to the previously selected mode Ramp There are 2 Ramp modes that can only be used when the ANGEL is in custom semi mode Soft ramp and Hard ramp There are 3 Parameters that can be adjusted to custom tune the ramp modes Start delay This is the number of shots fired before the ramp mode starts The range for the start delay is between 1 and 20 shots Kick in point This sets the minimum number of trigger pulls per second that must be reached in order for the software to add shots The range for the kick in point is between 4 and 16 trigger pulls per second Drop out point This sets the minimum number of trigger pulls per second that must be maintained in order for the software to add shots The range for the drop out point is between 4 and 16 trigger pulls per second Should the number of trigger pulls drop below this rate for more than 1 second the software will no longer add shots until the kick in point has been re achieved To enable any of the ramping features it must be selected from the custom modes menu PARAMETERS Valve dwell Dwell controls the valve opening time Longer dwell uses more gas and generates variable pressures Shorter dwell uses less gas and reduces noise but is less tolerant of poor quality paint and can result in weak shots The range of adjustment that is available is from 6 m
27. ecifically provided by the Uniform Commercial Code as adopted in Michigan as excluded modified and limited in this warranty 4 Additional Consumer Protection The products are offered for sale for end use in Supervised commercial establishments where professional safety codes are ANGEL enforced and not for personal family or household use Nevertheless if the Product is determined in a transaction to be a customer Product under applicable law the following provisions shall become applicable a THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS OF THE PRODUCT FOR A PARTICULAR PURPOSE THAT CANNOT BE DISCLAIMED ARE LIMITED IN DURATION TO THE INITIAL EXPRESS WARRANTY PERIOD b Some states do not allow limitations on how long an implied Warranty lasts so the above limitation in a may not apply c Some states do not allow the exclusion or limitation of incidental or consequential damages so such limitations may not apply d And this Warranty gives buyer specific legal rights and buyer may also have other rights provided for by law 5 Parts Service and Training performed by WDP All Warranty and non Warranty parts labour and service if any provided by WDP related to the product are subject to all limitations and disclaimers of warranties and remedies provided in this Warranty The replacement or repair of a product by WDP does not give rise to any new Warranty except the Warranty period provided
28. ecure fit e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE BOLT REMOVAL The ANGEL s bolt includes 2 gas ports that direct a small proportion of air onto the lenses of the ANGEL eye sensors which negates the need to clean them as regularly as other high end markers If you experience a serious breakage in the breech during a game your ANGEL eyes will switch off and under most circumstances you will be able to continue firing paint and the gas from the bolt ports will clean your ANGEL eyes You can then switch them back on by holding down the trigger for 2 seconds Note It is important that the bolt is kept clean and free from dirt or grit and that it is run dry with no lubricant We recommend that you clean your bolt after each day of use 4 Turn the breech release knob clockwise about a quarter of a turn PA Lift and rotate the breech block as illustrated Using the bolt pin slide the bolt from the breech Note If the breech will not open it may be the case that the bolt is in the forward position To check this look down the feed tube If you can see the bolt the breech will not open Push the bolt back into the marker as far as it will go the breech should now open Note To replace the bolt reverse these instructions 2 Note that the bolt pin must locate in the correct place to enable the breech to close CAUTION The ANGEL must not be fired without a bolt present This ca
29. elopment in trigger sensing function It achieves unsurpassed advancements in trigger repeatability and sensitivity its friction free non mechanical operating button results in faster shorter and lighter trigger strokes that give the user higher prolonged achievable rates of fire i Pull back collet gt MACRO LINE HOSE EJ Pull back the collet on the connector and keep the collet depressed and pull the Macro line hose out of the connector firmly 4 Cut back the Macro line hose cleanly and squarely Ai Push the hose firmly into the Macro line connector to re attach To remove IMPORTANT NOTE Please make sure that the Macro line is trimmed back before re insertion after it has been removed To attach PROPELLANT AIR NITROGEN SUPPLY The ANGEL is designed to operate on Air Nitrogen gas This needs to be supplied to the ANGEL using a suitable first stage regulator The ideal input pressure is 450 psi but the ANGEL will operate with an input pressure up to 850 psi Note Some preset systems will deliver a higher pressure than their rating So if you are using a High Pressure system rated at 850 psi this could lead you to inputting more pressure into the ANGEL than is recommended ADJUSTING OR REMOVING THE ASA ON ITS MOUNTING RAIL The ASA connects to the grip frame of the ANGEL via an integrated dovetail mounting rail that allows the user to slide the ASA body along the rail to fine tune the mou
30. f any such warranty or guarantee as given by the manufacturer to the company This warranty does not cover the following e Repairs alterations or replacements not authorised by the manufacturer e The gradual reduction in performance linked to the age of the ANGEL or usage e Anything caused directly or indirectly by vandalism or theft e Any damage to parts which are recalled by the Manufacturer e Any loss damage or failure which a qualified engineer appointed by the manufacturer believes could have been avoided or was totally or partly caused by a lack of maintenance Subject as expressly provided in these conditions and except where the goods are sold to a person dealing as a consumer within the meaning of the Unfair Contract Terms Act 1977 all warranties conditions or other terms implied by statute or common law are excluded to the fullest extent permitted by law Where the goods are sold under a consumer transaction as defined by the Unfair Terms in Consumer Contracts Regulations SI 1994 3159 the statutory rights of the purchaser are not affected by these conditions Carriage charges in relation to warranty claims shall be borne by the customer Where any valid claim in respect of the ANGEL is based in the quality or condition of the ANGEL or its failure to meet specification and such valid claim is notified to the company in writing and is in accordance with the company s standard terms and conditi
31. for herein shall be extended by the length of any period in which defective or non conforming product is in possession of WDP WDP may have access to the Product after purchase of the Product WDP is not under any duty to inspect the product for any defects or any improper use or modification of the Product nor to correct or advise anyone of any such condition use or modification which is observed Any notification which may be given is voluntary and subject to all limitations and disclaimers in this Warranty 6 User s Responsibility for Safety and Indemnification It is Buyer s or other user s responsibility to obtain all training and means that may be necessary to effectively protect all individuals and property from damage and bodily injury which otherwise may result from the use or maintenance of the Product and to use the Product in accordance with operating instructions and due care If operating instructions are not provided with the Product or have been lost a copy will be provided by WDP without cost on request The buyer shall use and shall require all others to use all safety devices and guards furnished with or intended to be used with the Product and to follow proper safe operating procedures in accordance with general industry standards and as set forth in manuals and instruction information furnished by WDP If the Buyer fails to comply with the obligations set forth in this section the Buyer s
32. gas pressure e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Always remove the first stage regulator and release all residual gas pressure from the ANGEL before disassembly e The ANGEL can hold a small residual gas charge typically two shots with the first stage regulator removed Always discharge the ANGEL in a safe direction to relieve this residual gas pressure e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE 4 Remove the back plate retaining screw using a 2 5mm Allen wrench A Remove the LPR chamber plug using a 4mm Allen wrench EJ Screw in the LPR pressure gauge until it stops turning Make a note of the pressure reading Should the reading be too high or low proceed to the next stage LPR Adjustment page 20 Note Remove the pressure gauge replace the LPR chamber plug and back plate and re gas your ANGEL ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e THE ANGEL IS LIVE AND CAPABLE OF DISCHARGING e Fire 6 shots with NO paintballs present to stabilize the LPR pressure i 7 ee LPR PRESSURE TEST The low pressure regulator controls the pneumatic cycle of the ANGEL and is located in t
33. ger for to the ANGEL 2 seconds The ANGEL s MROF will drop j i to its default MROF eyes off setting It will Te toppa emoe on Push amp hold k p fire 1 shot to confirm that the eyes have for 2 secs A l been switched off and the buzzer will e Ensure that there are no paintballs i sound once in the ANGEL VN Y E The eyes off symbol will be displayed on e Paintball industry standard eye face ear Loy ee the display screen The LED on the rear and head protection designed specifically of the grip frame will show red to stop paintballs and meeting ASTM e To turn the ANGEL eyes back on pull and standard F1776 USA or CE standard hold the trigger again for 2 seconds Europe must be worn by user and any The MROF will return to MROF eyes on person within range i setting see page 10 for factory default e SHOULD YOU BE UNSURE AT ANY STAGE setting the buzzer will sound twice and the eyes on symbol will be displayed on YOU MUST SEEK EXPERT ADVICE the display screen The LED on the rear of the grip frame will show blue e Should the eyes detect a malfunction due to a component failure or the eyes becoming dirty they will automatically turn themselves off and the MROF will revert to its MROF eyes off setting see page 10 for factory default setting the display will indicate that the eyes are off and that a ball is not detected OPTO BOARD The ANGEL incorporates the OPTO board This board is the latest dev
34. hall defend and indemnify WDP harmless from any claim liability or obligation incurred by WDP or its suppliers distributors or dealers to persons injured directly or indirectly in connection with the use of the product contrary to this Warranty or any warning or instruction from WDP 7 Law and Jurisdiction This Warranty shall be governed by the laws of Michigan and Buyer irrevocably submits to the non exclusive jurisdiction of courts sitting in Michigan to resolve all disputes arising from or related to this warranty or use of the Product 8 Claims and information procedure To make a warranty claim the Buyer must first contact the nearest authorised ANGEL Service Centre for instructions A list of authorised ANGEL Service Centres may be obtained through the WDP website www wdp tv or by contacting WDP by mail at WDP Metro Triangle 221 Mount Street Nechells Birmingham England B7 5QT or by fax at 44 0 121 327 3967 or by calling 44 0 121 328 2228
35. he left hand chamber at the rear of the ANGEL body The pressure needs to be approximately 6Opsi 4 14 bar output from an input pressure of 2 Opsi from the second stage regulator Your ANGEL has been tested and tuned to its optimum operating pressure at the factory using a 450psi input The ANGEL LPR utilizes shims as this is the best method of maintaining its optimum operating pressure If you are using a high pressure system you may need to reset the LPR You may also need to adjust the LPR once your ANGEL has bedded in but only if you are experiencing low velocity on your factory settings Once this is done you should only need to adjust the LPR if you change your Air Nitrogen system LPR adjustment is achieved by the addition or removal of shims Each shim equals approximately 2psi 0 14bar We recommend the use of the optional service tools and lubrication of parts with LOVE JUICE Extreme Grease only ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure that the ANGEL is de gassed and switched off READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE LPR ADJUSTMENT E AAND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Always remove the f
36. hlighted Push the navigation button inwards to select the Information menu Factory reset The default factory settings can be restored if required at any time e Press the internal button located on the circuit board inside the grip frame e The screen will display the internal options menu e Using the navigation button scroll up or down to select the reset function e Press the navigation button inwards to initiate the reset function e You will be asked to confirm that you wish to continue with this action Press the navigation button inwards to confirm this is correct e A reset message will be displayed on the screen confirming that the default settings have successfully been restored READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE GAME TIMER ALARM This is a fully interactive game timer with countdown alarm that will allow you and your team to play in unison The timer and alarm can be set in either 1 second or 1 minute increments from 0 to 60 minutes Once the alarm and timer are set they will be activated by the first trigger pull after making the ANGEL live and selecting the timer function e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highl
37. ight the Parameters menu e Push the navigation button in to select the Parameters menu e From the Parameters menu select the Game or alarm timer feature by pushing the navigation button inwards e Using the navigation button scroll up or down to highlight Change timer e Push the navigation button to select Change timer e Using the navigation button scroll up or down to select the first digit required e Push the navigation button inwards to store the first digit e Repeat the previous two points to store the 2nd 3rd and 4th digits Saved game timer game alarm message displayed on screen READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE TOURNAMENT LOCK To comply with some Tournament rules some of the ANGEL s features are required to be locked down so that they cannot be adjusted on the field of play El Press the internal button located on the circuit board inside the grip frame e The screen will display the internal options menu e Using the navigation button scroll up or down to highlight the Tournament lock function e Press the navigation button inward to initiate the Tournament lock features e Using the navigation button scroll up or down to highlight the Lock or Unlock feature as required e Press the navigation button inward to enable or disable the Tournament lock function as required e You will be asked
38. ill momentarily sound to indicate that the breakout mode has been initiated In order for the ANGEL to start firing in the breakout mode once it has been initiated a rate of trigger pulls higher than 4 per second must be reached and maintained within the time period that the breakout mode is active The duration of the time period that the breakout mode is active can be adjusted The range for this adjustment is 1 20 seconds If the rate of trigger pulls at any point once the breakout mode has been initiated falls below 4 per second or should the trigger be pulled and held in for 2 secs or the time period of the breakout elapses the breakout mode will revert to the previously selected mode ANGEL Hard breakout Once the hard breakout feature has been Selected from the custom modes screen and the ANGEL is on and live it will fire as if it were in normal semi auto mode until the breakout mode is activated To activate the breakout feature press the navigation button inwards The alarm will momentarily sound to indicate that the breakout mode has been initiated In order for the ANGEL to start firing in the breakout mode once it has been initiated the trigger must be pulled and held in within the time period that the breakout mode is active The duration of the time period that the breakout mode is active can be adjusted The range for this adjustment is 1 to 20 seconds If the trigger is released at any point once the br
39. illiseconds to 15 milliseconds in 0 5 millisecond increments Important Note The internal lock button must be used to turn Dwell options on or off e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highlight the Parameters menu e Push the navigation button in to select the Parameters menu e From the Parameters menu select the Dwell feature by pushing the navigation button inwards e Scroll up or down through the Dwell settings by pushing the navigation button up or down e Once the desired setting has been reached press the navigation button inwards to save the new setting e A Saved Dwell message will be displayed The Parameters menu will be displayed De Bounce This is the length of time that the trigger has to be pulled for it to be accepted by the electronics as a valid trigger activation There are 20 levels of adjustment 1 being the least sensitive and 20 the most sensitive adjustment e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE a PARAMETERS conr cont
40. irst stage regulator a E i P eas and release all residual gas pressure from HA tt Nhe ee g ge the ANGEL before disassembly Dki p The ANGEL can hold a small residual E Remove the LPR chamber plug using gas charge typically two shots with the a 4mm Allen wrench 3 E first stage regulator removed Always k discharge the ANGEL in a safe direction to relieve this residual gas pressure Bcc sata s5 d e SHOULD YOU BE UNSURE AT ANY STAGE or remove shims to increase i or decrease pressure respectively i ane S d Eee EERE One shim equates to approximately 2 psi change in pressure Replace the LPR piston LPR chamber plug back plate and re gas your ANGEL To check the LPR pressure see page 19 ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure that the ANGEL is de gassed and switched off EJ Using the extraction tool provided withdraw the LPR piston carefully LPR ASSEMBLY Note The LPR may be serviced The order once it has been removed by ee see Of the three following the LPR assembly A ee ri active springs procedure on page 21 The should not be serviceable parts are the external O rings and the LPR spool E LPR spool EJ LPR body G Al Piston spacer i sprna i Dy LPR shims _ las fl LPR spring stack A LPR piston H LPR circlip LPR SPOOL REMOVAL 5 Using a suitable pick remove the LPR circlip from the LPR body J W
41. isplayed on the screen and the ANGEL will power down MAKING YOUR ANGEL SAFE When you turn the ANGEL ON the ANGEL is LIVE To make the ANGEL SAFE either e Access the menu options by pushing the navigation button up or down and holding for 2 secs The ANGEL is still LIVE and capable of firing e Choose SAFE from the menu options When the ANGEL is SAFE a screen similar to that on the left will show The screen will indicate the ANGEL is SAFE The screen will also indicate the mode you are in and whether the tournament lock is on or off 4 The LED on the rear of the grip frame will show green READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE NAVIGATION BUTTON E The functions features and settings of the ANGEL are controlled by a 3 directional navigation button located on the rear of the grip frame FA The button can move up and down to scroll through features and settings indicated on the display and can be pressed in to select the highlighted function or setting required The navigation button is located on the rear of the grip frame and allows access to the ANGEL internal menu option Push the button up or down and hold for 2 seconds oF ee Meo a To navigate through the options simply push the button up to scroll up and push the button down to scroll down Press the button inwards to make a selection BATTE
42. ith the LPR circlip removed separate the LPR spool from the LPR body ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Always remove the first stage regulator and release all residual gas pressure from the ANGEL before disassembly e The ANGEL can hold a small residual gas charge typically two shots with the first stage regulator removed Always discharge the ANGEL in a safe direction to relieve this residual gas pressure e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE To remove the LPR spool from the LPR body see page 20 LPR REMOVAL If you are experiencing operating pressure inconsistency this may be due to a damaged spool seal on your LPR This seal is shown in red on the LPR Spool A shown on page 20 li Remove the right hand grip cheek by removing the 3 screws using a suitable 2mm Allen wrench 2 Carefully unplug the solenoid from the board z EJ Carefully unplug the eye ribbons from the board 4 Remove the two screws retaining the grip frame using a 2mm Allen wrench Fl Remove the bolt as described on page 7 i Remove the back plate retaining screw 2 5mm Allen wrench and remove the back plate Remove the LPR chamber plug using a 4mm Allen wrench FY Loosen the top plate retai
43. n result in damage to your ANGEL Any damage caused from failure to follow these instructions is not covered by your ANGEL warranty VELOCITY ADJUSTMENT 4 Using a 3mm Allen wrench turn the velocity adjuster screw either Fl clockwise to decrease velocity H counter clockwise to increase velocity READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE OLED MENU Status The Status menu allows you to select between Live Safe the Information display screen and the Parameters setting e To access the Status menu press and hold the navigation button up or down for 2 seconds Note If a trigger pull has been made immediately prior to pressing the navigation button then a further 5 second delay will be initiated to prevent accidentally putting the ANGEL in SAFE during a game situation e Once in the Status menu use the navigation button to scroll up or down to choose between Live Safe Information and Parameters e Pressing the navigation button inwards will select the highlighted function The Information screen will display all the relevant information relating to the electronic settings of your ANGEL e With the ANGEL on and Live push the navigation button up or down for 2 seconds e The ANGEL will be in the Status menu e Use the navigation button to scroll through the Status menu settings until Information is highlighted e Push the navigati
44. n this direction as it will result in not enough travel for a trigger pull to activate the button 4 Counter clockwise moves the point from which the trigger pull starts forwards away from the grip cheek Clockwise moves the point from which the trigger pull starts backwards towards the grip cheek Note It is important not to over adjust the front stop position set screw in this direction as it will result in not enough return travel for the trigger to reset the Magnet return strength 5 Counter clockwise makes magnet return strength weaker Clockwise makes magnet return strength stronger It is important not to over adjust this portion of the trigger as it will negate the position of the front stop set screw For this reason it is advisable that during the setup of the trigger you should wind the magnetic return strength adjuster screw counter clockwise_ several turns so that it does not interfere with the adjustment of the front stop set screw Activation point 4 Counter clockwise moves the point at which the trigger will activate closer to the end of the trigger pull Clockwise moves the point at which the trigger will activate closer to the start of the trigger pull Front stop Important Note When reassembling the trigger note the orientation of the trigger clamp plate and ensure that the clamp plate is located correctly on the trigger bearings
45. navigation button up or down Once the desired setting has been reached press the navigation button inwards to save the new setting READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE A Saved Paint Type message will be displayed The Parameters menu will be displayed MROF eyes on This allows the user to set the Maximum Rate of Fire whilst the ANGEL eyes are on There are 20 levels of adjustment ranging from 10 to unlimited balls per second e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highlight the Parameters menu e Push the navigation button in to select the Parameters menu e From the Parameters menu select the MROF eyes on feature by pushing the navigation button inwards e Scroll up or down through the MROF eyes on settings by pushing the navigation button up or down e Once the desired setting has been reached press the navigation button inwards to save new setting A Saved MROF eyes on message will be displayed The Parameters menu will be displayed MROF eyes off This allows the user to set the Maximum Rate Of Fire whilst the ANGEL eyes are off There are 20 levels of adjustment ranging from 10 to unlimited balls per second e Ensure that th
46. ning screw using a 2 5mm Allen wrench Fy and slide the top plate from the body ET Carefully lift and remove the solenoid carefully extracting the solenoid plugs from the grip frame housing noting the orientation of the gasket EE Extract the LPR retaining pin 12 Remove the LPR piston using the extraction tool supplied EE Using a blunt pick remove the solenoid piston spacer EE Using a blunt pick extract the LPR body 15 Check the spool seal for signs of damage and replace spool assembly if necessary The spool assembly is part of the comprehensive ANGEL spares kit To rebuild reverse this procedure LPR spool removal READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE 22 94 a EXHAUST VALVE STEM REMOVAL The magnetic exhaust valve in your ANGEL FLY reduces its working pressure by over 80psi 30 on the ANGEL A1 The ANGEL FLY s 200 psi working pressure reduces its kick making your ANGEL FLY even softer on paint than the ANGEL A1 If you are experiencing gas leaking from the breech area first ensure your tank is delivering at least 200 psi to your ANGEL If you are still experiencing operating pressure related problems with your ANGEL such as gas leaking from the breech area inability to achieve the required velocity or increased noise when shooting your ANGEL may have a damaged exhaust stem face seal This seal
47. nting position or remove the ASA completely The ASA body is locked down onto the rail via two set screws located within a central recess at the front and back of the integrated rail INSTALLING AN AIR NITROGEN SYSTEM Each ANGEL comes complete with a centrally ported on off ANGEL ASA allowing for the easy connection of a preset air nitrogen system for immediate use 6 Before installing your preset system into the ASA always ensure that the on off adjuster knob is wound out approximately halfway Be careful not to unscrew the ASA on off adjuster knob too far as it is possible to completely disassemble the ASA FA To install your air or nitrogen system screw your tank and regulator onto the ASA and tighten 1 Using a 3mm Allen wrench remove the screw at the front of the ASA Al Using a 3mm Allen wrench remove the screw at the rear of the ASA EW Slide the ASA forward or backward to the desired position Depression Pin Note Pin orientation OR E Slide the ASA clear of the mounting bracket to remove completely E When disassembling the ASA note the orientation of the depression pin ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Always follow instructions warnings and guidelines given with any first stage regulator you use with the ANGEL e Use compressed air nitrogen gas only DO NOT USE C02 e Only use a paintball regulato
48. ode setting has been reached press the navigation button inwards to save the new setting e A Saved Mode message will be displayed The Parameters menu will be displayed The ANGEL eyes will default to on whenever the ANGEL is made live via the navigation button With the eyes activated the ANGEL will only fire when a paintball is present and has been detected by the ANGEL eyes With the eyes activated the MROF that the ANGEL will fire at is limited by the MROF eyes on level With the eyes turned off the MROF that the ANGEL will fire at is limited by the MROF eyes off level The ANGEL will fire 1 shot for each pull of the trigger Breakout and Ramp settings do not function in this Mode NPPL The ANGEL eyes will default to on whenever the ANGEL is made live via the navigation button With the eyes activated the ANGEL will only fire when a paintball is present and has been detected by the ANGEL eyes With the eyes activated the MROF that the ANGEL will fire at is limited by the MROF eyes on level READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE With the eyes turned off the MROF that the ANGEL will fire at is limited by the MROF eyes off level The ANGEL will fire 1 shot for each pull of the trigger Breakout and Ramp settings do not function in this Mode The ANGEL eyes will default to on whenever the ANGEL is made live via th
49. on button inwards to select the Information menu e The following information will be displayed on the OLED Scroll up or down using the navigation button to view this information Status Software version Mode Soft breakout setting Hard breakout setting Soft ramp setting ORCUTT Dwell time MROF eyes on limit MROF eyes off limit De bounce level Paint Type Shot filtering Anti Bolt Stick ANGEL eyes on off Game timer set Alarm time set Total shots fired since reset Parameters The ANGEL s settings can be easily adjusted from the Parameters menu e With the ANGEL on and Live push and hold the navigation button up or down for 2 seconds e The ANGEL will be in the Status menu e Use the navigation button to scroll through the Status menu settings until Parameters is highlighted e Push the navigation button inwards to select the Parameters menu The following functions are all accessible via the navigation button and can all be accessed and adjusted from the Parameters display Modes Valve Dwell De bounce Paint Type MROF eyes ON MROF eyes OFF Breakout Ramp feature Shot Filter ABS Game Timer Set Alarm Time Set A WARNING ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face
50. on using the navigation button by pressing it inwards to confirm the desired option e Select the duration that you wish the breakout to be active for by using the navigation button to scroll between the values of 1 and 20 seconds then press the navigation button inwards to confirm your desired settings A Saved Soft Hard Breakout message is displayed The Breakout menu will be displayed This allows the user to select 2 levels of ramp mode Soft Ramp and Hard Ramp Once the level of Ramp has been selected the user can then customize the ramp mode by selecting the start delay number of shots to be fired before the ramp mode activates adjustable between 1 and 20 shots kick in BPS number of trigger pulls per second that has to be reached to get the ramp mode to start adjustable between 4 and 16 shots and the drop out BPS minimum number of trigger pulls that must be maintained in order to keep the ANGEL in ramp mode adjustable between 4 and 16 shots ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE U
51. ons of sale the company shall be entitled to repair or replace the goods or the part in question free of charge or at the company s sole discretion refund to the purchaser the price of the goods or a proportionate part of the price but the company shall have no further liability to the purchaser Except in respect of death or personal injury caused by the company s negligence the company shall not be liable to the purchaser by reason of any representation or any implied warranty condition or other term or any duty at common law or under the express terms of this guarantee for any direct or indirect special or consequential loss or damage whether to persons or property costs expenses or other claims for compensation or damages whatsoever whether caused by the negligence of the company its employees or agents or otherwise which arise out of or in connection with the supply of the ANGEL its use or misuse or resale by the purchaser or any individual and the entire liability of the company under or in connection with the purchase or use or misuse of the ANGEL shall not exceed the purchase price of the ANGEL Purchaser agrees to adhere strictly to all warnings and Safety procedures and the contents of the Operator s Manual The laws of England shall govern this warranty and the purchaser agrees to submit to the non exclusive jurisdiction of the English courts The supply and purchase of the ANGEL is subject
52. r that has been designed for air or nitrogen gas e Do not exceed 850 psi 68bar input pressure to the ANGEL e Take suitable precautions when using sharp cutting instruments e The Macro Line hose must be cut back cleanly and square prior to attachment or re attachment to ensure secure fitment e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Ensure the ANGEL is switched off via the navigation button on the rear of the grip frame prior to fitting your first stage regulator e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e Always follow instructions warnings and guidelines given with any first stage regulator you use with the ANGEL e Use compressed air nitrogen gas only DO NOT USE C02 e Only use a paintball regulator that has been designed for air or nitrogen gas e Do not exceed 850 psi 58 bar input pressure to the ANGEL e Take suitable precautions when using sharp Cutting instruments e The Macro Line hose must be cut back cleanly and square prior to attachment or re attachment to ensure s
53. s Is a Suitable working loader fitted Check loader specifications ls the correct paint type selected Change Paint Type settings 12 ls the rate of fire set too high MROF Adjustment 12 Are the rubber finger detents functioning Clean or replace 17 Is the paint too fragile for the loader Change paint to tougher grade CHOPPING PAINTBALLS ls the loader battery weak dead Replace batteries Is a Suitable working loader fitted Replace loader Is the loader dirty Clean loader Are the paintballs swollen Replace the paintballs Are the ANGEL Eyes switched on Switch ANGEL Eyes on 5 Are the ANGEL Eyes functioning ANGEL Eyes Test 5 17 Is the correct paint type setting selected Change Paint Type settings 12 Is the Rate Of Fire set too high MROF Adjustment 12 Are the rubber finger detents functioning Clean or replace 17 FIRING TOO SLOWLY ls the rate of fire set correctly MROF Adjustment 12 ls the loader battery weak dead Replace batteries Is a Suitable working loader fitted Replace loade Is the loader dirty Clean loader Are the ANGEL Eyes switched on Switch ANGEL Eyes on 5 ls the correct paint type selected Change Loader Type settings 12 Is the Rate Of Fire set too low MROF Adjustment 12 EXCESSIVE NOISE GAS CONSUMPTION Is the valve Dwell set correctly Dwell Adjustment 11 Is the LPR pressure set correctly LPR Adjustment 20 Is the exhaust valve worn Exhaust Valve replacement 22 Is
54. ss the bolt is in the backward position g Remove the back plate retaining screw 2 5mm Allen wrench and remove the back plate Remove the LPR chamber plug using a 4mm Allen wrench 8 Withdraw the Ram retaining pin E The Ram can now be withdrawn To rebuild reverse this procedure IMPORTANT NOTES For re assembly of components e Ensure the Ram assembly is lubricated with Love Juice Extreme Grease prior to refitting e Ensure the Ram assembly external O rings are not damaged e Ensure the Ram assembly is inserted slowly to prevent damage to the O rings e Note that to replace the Ram retaining pin the holes in the gun body EY and in the Ram itself EJ must be aligned READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE 24 ie yi E T TRIGGER ADJUSTMENT Back stop The trigger system has four adjustable points back stop front stop magnetic return strength control and activation point When adjusting the trigger it is advisable to set both the front and back stop positions before you proceed to set the return strength or activation point 4 gt Counter clockwise moves the point at which the trigger stops backwards towards the grip cheek Clockwise moves the point at which the trigger stops forwards away from the grip cheek Note It is important not to over adjust the back stop position set screw i
55. standard F1776 USA or CE standard Europe must be worn by user and any person within range e You must be at least 18 years of age to purchase the ANGEL e Persons under 18 years of age must have adult supervision when using or handling the ANGEL e Observe all local and national laws regulations and guidelines e Use only on professional paintball fields where codes of safety are strictly enforced e Use 0 68 calibre paintballs only e Keep the ANGEL switched off until ready to shoot e Treat every ANGEL as if it is loaded e Never point the ANGEL at anything you do not intend to shoot e Do not shoot at persons at close range e Do not shoot at fragile objects such as windows e Always measure your ANGEL s velocity before playing paintball using a suitable chronograph e Never shoot at velocities in excess of 300 feet 92 meters per second or at velocities greater than local or national laws allow e Do not fire the ANGEL with the breech open or without the bolt in the breech as high pressure gas will be emitted e Use compressed air nitrogen gas only Do not use C02 READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE e Always follow instructions warnings and guidelines given with any first stage regulator you use with the ANGEL e Do not fire the ANGEL with the breech release knob in the unlocked position e Never look into the barrel or
56. the barrel bore correct for the paint Use a suitable barrel READ ALL WARNINGS BEFORE ATTEMPTING ANY WORK ON YOUR ANGEL SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE ANGEL TERMS OF WARRANTY EEC R O W EXCLUDING USA CANADA Subject to the conditions set out below WDP warrants that the ANGEL will correspond to its specification at the time of delivery and will be free from defects in materials and workmanship for a period of six months from the date of purchase WDP gives this warranty subject to the following conditions e Proof of purchase is required in all warranty claims e Warranty is not transferable e The company shall be under no liability in respect of any defect arising from fair wear and tear e Seals batteries wiring circuit boards displays and exhaust valves are not covered by this warranty Wilful damage negligence abnormal working conditions weather accident tampering failure to follow manufacturers instructions whether oral or in writing misuse or alteration or repair of the ANGEL without the company s written approval will invalidate this warranty and the company shall be under no obligation whatsoever to the purchaser in respect of any of the above breaches of this warranty e The above warranty does not extend to parts materials or equipment not manufactured by the company in respect of which the purchaser shall only be entitled to the benefit o
57. the first shots fired after this inactivity being lower in velocity because the seals need to break free from the forces of the static friction Anti Bolt Stick programming allows the dwell time to be increased for the first 2 Shots if the ANGEL has been inactive for 15 seconds to overcome static friction There are 20 levels of ABS adjustment ranging from 0 25 milliseconds to 5 milliseconds e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highlight the Parameters menu e Push the navigation button in to select the Parameters menu e From the Parameters menu select the Anti Bolt Stick feature by pushing the navigation button inwards e Scroll up or down through the Anti Bolt Stick settings by pushing the navigation button up or down e Once the desired setting has been reached press the navigation button inwards to save the new setting A Saved Anti Bolt Stick message will be displayed The Parameters menu will be displayed Software version The software version is displayed on the information page e With the ANGEL on and Live push the navigation button up or down for 2 seconds i a m WwW e The ANGEL will be in the Status menu e Use the navigation button to scroll through the Status menu settings until Information is hig
58. there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE purposes as the ANGEL eyes feature is reverse functioned so that it cannot fire should a paintball be detected Breakout and Ramp settings do not function in this Mode The ANGEL eyes will default to on whenever the ANGEL is made live via the navigation button With the eyes activated the ANGEL will only fire when a paintball is present and has been detected by the ANGEL eyes With the eyes activated the MROF that the ANGEL will fire at is limited by the MROF eyes on level With the eyes turned off the MROF that the ANGEL will fire at is limited by the MROF eyes off level The ANGEL will fire 1 shot for each pull of the trigger Breakout and Ramp settings can be used individually or in combination in this Mode There are 2 breakout modes that can only be used when the ANGEL is in custom semi mode Soft breakout Once the soft breakout feature has been Selected from the custom modes screen and the ANGEL is on and live It will fire as if it were in normal semi auto mode until the breakout mode is activated To activate the breakout feature press the navigation button inwards The alarm w
59. tment of the point within the current firing cycle that a new buffered shot will be accepted The Shot filter is adjustable from 1 to 20 levels Level 1 turns the shot filtering off which allows the additional shot to be registered at the earliest point after the eyes have detected a ball and the trigger has provided a viable fire command Levels 2 through to 20 sets the of the firing cycle that must have been completed before the additional shot may be allowed from 10 of the cycle increasing in 5 increments up to a maximum of 100 of the cycle e Ensure that the ANGEL is switched on e Ensure that you are not activating the trigger e Push and hold the navigation button UP or DOWN for 2 seconds e The Status menu will be displayed e Push the navigation button up to highlight the Parameters menu e Push the navigation button in to select the Parameters menu ANGEL e From the Parameters menu select the Shot Filtering feature by pushing the navigation button inwards e Scroll up or down through the Shot Filtering settings by pushing the navigation button up or down e Once the desired setting has been reached press the navigation button inwards to save the new setting A Saved Shot Filtering message will be displayed The Parameters menu will be displayed Anti Bolt Stick First shot drop off can occur when the valve or Ram incurs static friction after a period of inactivity This results in
60. to confirm that you wish to continue with this action Press the navigation button inwards to confirm this is correct e A padlock icon will be displayed on the screen indicating the Status of the tournament lock e The following features are affected by the tournament lock Modes MROF eyes ON MROF eyes OFF Dwell De Bounce Shot filtering Anti Bolt Stick In order to adjust any of these features the tournament lock must be disabled ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE A WARNING ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHO
61. ved from the ANGEL e Ensure that there are no paintballs in the ANGEL e Paintball industry standard eye face ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 USA or CE standard Europe must be worn by user and any person within range e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE IMPORTANT NOTE e When accessing the status menu from the LIVE screen the ANGEL will remain LIVE and any trigger pull will return you to the LIVE screen e f accessing any of the other menus from the status menu the ANGEL will revert to SAFE and any trigger pull will return you to the SAFE screen A WARNING Push amp hold navigation button for up to 2 secs status Ball status Game timer status Screen shows Eyes on and ball detected Tournament lock status Screen shows Eyes SWITCHING ON YOUR ANGEL E To switch the ANGEL ON press and hold the navigation button inwards for up to 2 seconds The ANGEL will turn ON and will automatically go into LIVE mode with the eyes on The display screen will illuminate and will show the firing status of the ANGEL A The LED on the rear of the grip frame will show blue LIVE LLL I LIVE tiit Screen shows Eyes are off are faulty TURNING OFF YOUR ANGEL 3 Switch the ANGEL OFF by pressing and holding the navigation button for 2 seconds A goodbye message will be d
62. w the bottom section of the fore grip and remove EJ Remove the fore grip cap using a suitable wrench E Using the extraction tool provided remove the minireg cartridge It may be necessary to remove the fore grip completely in order to facilitate access to the underside of your ANGEL To do this Ai Using a 4mm Allen wrench remove the fore grip retention screw 6 Remove the top section of the fore grip Note If replacement of the macro line hose connector is required remove the regulator end cap from the fore grip before attempting to replace the fitting Failure to do so can result in damage to the regulator end cap or the fore grip Minireg cartridge assembly Note the spring stack order ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES e Ensure a barrel blocking device is fitted to the ANGEL e Ensure the hopper is removed from the ANGEL e Ensure that there are no paintballs in the ANGEL e Always remove the first stage regulator and release all residual gas pressure from the ANGEL before disassembly e The ANGEL can hold a small residual gas charge typically two shots with the first stage regulator removed Always discharge the ANGEL in a safe direction to relieve this residual gas pressure e SHOULD YOU BE UNSURE AT ANY STAGE YOU MUST SEEK EXPERT ADVICE ANGEL ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY
Download Pdf Manuals
Related Search
Related Contents
Craftsman 40-Volt Owner's Manual Installation Manual NAVIGATIONAL ECHO De'Longhi Dragon4 Instruction Manual GRYPHON Z87 Service Service Service 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file