1. No These values can be read later with the PC software In the meanwhile you can do a manual registering to make the correspondance between the file number and the measured items example file 1 table mat file 2 ground mat 3 2 Timer If the timer is not activated the EUROSTAT 600 directly switches on the resistance display in the on line operation According to the chosen display mode and voltage mode in the display appears Example R 5 5xE10Q T OFF amp AUTO AIR xx C xx r F 4 Other Display Information s If the maximum measurement is exceeded appears at the display Measure voltage Auto 100V R gt 2 0xE12Q0 R gt 2 0 TO Measure voltage 10V R gt 2 0xE11Q R gt 200 GO If the minimal measurement is under stride appears at the display Measure voltage Auto 10V R lt 2 0xE04Q R lt 20 kQ Measure voltage 100V R lt 1 0xE05Q R lt 100 kQ By searching the measure range it appears in the 1 line of the display WAIT When the battery voltage is lower than 4 6Volt it appears in the 2nd line of the display alternate to the actual display message LOW BATTERY E U ROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 The accumulator must be charged again but the current measurement can be completed If the Battery Voltage is lower as 4 3 volts the following display appear and the unit automatically switches off to save the batteries LOWEST BATTERY AUTO SWITCH OFF 4 1 Di
2. and place on the probe e During the measurement of very high ohm resistors is to be kept that no influence effect is happen on the measure input How to select the parameters After switching on first the software version is shown TOM 600 V3 0 KL 03 2004 Provided the timer is ON in the display appears press start You can start the measure by pressing key A start The current resistance value and the timer attitude are shown afterwards gt 2 0xE12Q T OFF Air xx C xx r F If the timer should be turned off immediately appears at the display gt 2 0xE12Q T OFF E U ROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 mathematical representation of technical representation lt 2TQ Alternating to the timer display T OFF is shown the measure voltage mode Auto 100V or 10V To turn off the appliance press again key B In the battery mode the unit turns off if no button was pressed automatically after approximately 5 minutes 2 2 Charging the NiMH Battery The EUROSTAT TOM600 allowed only to operating directly with the enclosed power supply Also only with these the installed NiMH batteries can be charged Connect the power supply to the integrated socket and connect the plug power supply to a power socket If the appliance is switched off and the charging work correct the green Charge LED shines The NiMH batteries are completly charged after maximum of 14 hours and good f
3. 60 C Tolerance 3 C Humidity 10 90 r F Tolerance 5 PC Interface serial Interface 9 polige SUB D connector PC Software Excel Software for Data reading and remote control Battery 4xMignon AA NiMH 2100 mAh E U ROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 Operating time of the completely charged battery gt 12 hours of continuous operation Charge time with enclosed power adapter maximum 14 hours Power Supply 9V DC 300 mA 8 Safety Advice The measurement unit is not approved for the use in explosive areas The unit is not approved for the use in power utilities Info Make sure that there is no voltage on your measuring External Voltage gives you a wrong measure value and can destroy your instrument 9 Parts of Delivery EUROSTAT TOM600 Partnumber 61 200 0601 e Tera Ohmmeter EUROSTAT 600 with temperatur and huminity sensor e 4pce rechargeable NIMH Mignon AA Batteries conductive suitcase with foam insert Plug Power supply 9V DC 300mA 2 pce Teflon insulated measurement cord 1m Serial PC Cable 9 pol 3 5 Disk with Excel PC Software and manual Operating Instructions e Certificate of factory calibration EUROSTAT 600 ME incl measure electrodes Partnumber 61 200 0600 e 1 pce Teflon insulated measurement cord Im e 1 pce Teflon insulated measurement cord 5m e 2 50 kg Electrode pair trough EOS ESD S 4 1 S 7 1 and DIN EN 61340 5 1 4 1 2 3 For
4. E U ROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 SURFACE RESISTIVITYMETER m EUROSTAT TOM600 The Surface Resistivimeter EUROSTAT 600 operates with the Voltage Current Measurement High resistances up to 2x10 Ohm 2 TERA Ohm can be measured with a voltage of 100 volts and a precision of 1 x10 As peculiarity the ambient temperature and the humidity will be measured and stored to every measured resistance value EUROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 List of contents 1 Description 3 2 Operation Instruction 3 2 1 Start up 3 2 2 Charging the battery 4 2 3 Measureranges and Voltage 4 3 Set Up Functions 4 3 1 Measure Voltage Display Mode 5 3 2 Timer 6 4 Other Display Information s 6 4 1 Display Contrast 6 5 PC Operating 7 5 1 system requirements 7 5 2 Softwareinstallaion 7 5 3 Starting the Software 7 6 Warranty 7 7 Specifications 7 8 Safety Advice 7 9 Delivery capacity 8 10 Optional accessories 8 11 Maintenance Calibration 9 12 Legend 9 13 Schema 10 E U ROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 1 Description The surface resistivimeter EUROSTAT TOM600 is suitable very well for the mobile use in industrial areas through its compact housing and through the battery power It can also be used stationary with a plug power supply Important Don t use the AC Adapter when rechargeable batteries are installed The EUROSTA
5. Measuring Grounding Resistors and point to point resistance specially for installed ESD Table or floor coverings 10 Optional accessories EU ROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 e Ring Electrode to EOS ESD S 11 11 DIN EN 61340 5 1 2 3 comprising to the measurement of transit and surface resistances 1 shielded and 1 no shielded Measure cord other electrodes are available on inquiry 11 Maintenance Calibration The appliance is maintenance free If the appliance should get dirty it can be cleaned with a lint free cotton cloth with solvent free detergent Don t open the housing When the housing was opened you loose warranty If the appliance should not be used for a longer time remove the Batteries out of the appliance The interval for factory calibration is normally 1 year 1 Power Supply connector 9V DC 2 Serial PC Interface 3 Measure Voltage Output 4 Measure Input 5 Contrast Potentiometer for LC Display 6 Temperature Humidty Sensor 7 Charge control LED E U ROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 13 How to install the tester It is preferable to connect the smallest cord on the yellow side amplifier side and the long cord on the red side When using a single cord prefer the yellow side INPUT 1 Method to measure surface resistivity Point to point according toNorm CEI 61340 5 1 2 Transversal resistivity 3 Resista
6. T 600 is menu controlled has only two buttons and so it is very operator friendly All parameters are shown at the LC Display The included PC Software is for remote controlled usage and additionally measuring results can be administered and processed The EUROSTAT TOM600 works with the voltage current measure principle To the transactions of the measurements anuses of tied up Norm DIN EN 61340 EOS ESD 4 1 6 1 the measuring time can be selected with the internal timer At Timer ON the measurement values inclusive the air parameters can be stored in the internal EEPROM They don t are deleted by switching off the unit The values can be read out trough the PC Interface at all times Since the resistance values depend very strongly on the Humidity and the air temperature these influences are measured together with the resistance value So a reproducible measurement is given 2 Operating Instruction 2 1 Start operation The Surface resistivitymeter EUROSTAT TOM600 is delivered with 4 x Mignon AA NiMH Batteries and is directly ready to start For charging the batteries and stationary operation use the enclosed plug power supply only be Generallys speaking the programm choice is done with B knob and the validation with A knob Push on knob B ON OFF to start and then knob A START to start the measure directly e The electrodes are connected to the corresponding sockets s legend
7. em partnumber 61 200 0600 By pressing key B Change it appears T 002s and than in 1 second Steps up tol0 Second After that the timer starts with T 010s the changing steps are now 10 Seconds up to 60 Seconds after this you get 60 second steps up to 240 seconds Press the A Set Up key to choose the displayed timer time At the display appears TIMER MODE AVERAGE LAPSE By pressing key B Change the timer is switching between AVERAGE and LAPSE Press the A Set Up key to choose the displayed timer mode Now it is asked whether you will delete the EEPROM stored data files In the display appears DEL FILES YES NO By pressing key B Change the display is switching between YES and NO By pressing the A Set Up key if YES is displayed all files in the EEPROM memory will be erased By pressing the A Set Up key if NO is displayed no file will be erased and the next file is storage by the next free file number In the 1 line at the display appears for approximately 2 seconds WAIT After that it appears in the 2 line FILES DELETED 3 1 Measure Voltage Display Mode Choice of the voltage the tester asks to choose a voltage AUTOMATIQUE mode must be preferred The tester measure automatically under 10V and then under 100V MANUAL mode and 10 V voltage allows you to measure resistances of 20 kilo ohms to 200 giga ohms For a voltage of 100V yo
8. nce to ground 10 EUROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 CS
9. or gt 10 hours continuous operation A longer charging time can dammage the batteries 2 3 Measure range and measure voltage The EUROSTAT TOM600 has an automatic ranging approve the whole resistor range The appliance accordingly the measure resistance selects the Measure voltage automatically e Measured resistance less then 200 KQ Measure Voltage 10 VDC e Measured resistance more then 200 KQ Measure Voltage 100 VDC In the Set Up this automation can be switched off and a constant measure voltage can be select The measure ranges are than as following e Measure voltage 10V measure range 20kQ 200GQ e Measure voltage 100V measure range 100kQ 2TO 3 Set up Function Choice of the measure time In all cases the tester measures each 0 1 seconds if the selected time is 3 secondes 30 measures will be taken Mode LAPSE the last measure is displayed Mode AVERAGE the mean of all measures is displayed By pressing the key A Set Up longer as 2 seconds the set up function is starting At the display appears SET TIMER TIMER OFF On By pressing key B Change the timer is switches between off and on If pressing key A Set Up by TIMER OFF the timer is switched off and you can continued by point 3 1 If you press the key by TIMER ON you can now choose the measure time In the display appears NEW TIMER TIME 001s E U ROSTAT User manual TOM600 GROUP It
10. splay contrast On the front side left from the PC Interface there is a hole trough this you can screw a potentiometer for adjust the Contrast of the LCD Display 5 PC Operating 5 1 System requirement PC with 486er CPU or higher 3 5 Floppy disk 1 44MB free serial Interface COM1 or COM2 Windows98 2000 Xp with EXCEL 5 2 Installations Put the disk with the TOM software into the floppy drive Make a Double click in the Explorer of the Install file and following the instructions The software is now installed 5 3 Start the Software Connect the TERA Ohmmeter with the PC Interface cable to a free serial PC Interface COM 1 or 2 from your PC and press key A to switch on the TERA Ohmmeter Make a Double click at the Desktop at the EUROSTAT 600 Icon The software will start automatically when Excel is installed at your PC 6 Warranty We provide 24 month warranty from date of receiving the unit if the unit was handled properly The damage of the NiMH batteries caused by improper handling as well as mechanical damage on the unit are excluded from warranty Warranty is not provided if the housing was opened T Technical Specifications Housing Plastic Housing 223 mm x 81 5 106 mm x 40 59 mm L x B x H Weight app 350 g Display alphanumeric Display 2 lines with 16 Letters Display field 60 mm x 25 mm Measure Ranges Resistor 20 kQ 2 0 TQ Tolerance 1xEXX Q Temperature 0 C
11. u can measure resistances from 200 kilo ohms to 2 Tera ohms Now it will be ask for your choose off the measure voltage In the display appears VOLTAGE MODE AUTO MAN 10V MAN 100V By pressing key B Change the display is switching between AUTO Automatic MAN 10V and MAN 100V Press the A Set Up key to choose the displayed voltage mode After that it will be ask for your choose off the display voltage DISPLAY MODE R gt 2 0xE120 R gt 2 0 TQ By pressing key B Change the display is switching between the mathematical and technical display form Press the A Set Up key to choose the displayed display time E U ROSTAT User manual TOM600 GROUP Item partnumber 61 200 0600 Now the unit will execute a reset and in the display appears if timer is on else go to point 3 2 Timer off T xxxs Avg Auto Lap 10V 100V PRESS START By pressing key A Start the next measurement will be started The timer decrements in 1 second steps up to Zero then the measure value will appears in the display as Ravg by AVERAGE Mode and Rlap by Lapse Mode In the 2 line the air temperature and the humidity is displayed Ravg 2 5xE9Q Rlab 2 5 GQ AIR xx C xx r F Alternates all 2 second in the 2 line appears FN xxx T xxxs By pressing key A Start the measure value together with the air temperature and the Humidity will be saved in the EEPROM using the displayed File