Home

User Manual AO 6004 rev C

image

Contents

1. s s ssssssssssssrssrsn 2 pieces RJ45 Analog outputs connectors 4 XLR3 male connectors User Manual Remote Control commands in out By using SW 6000 control of the AO 6004 through the CU 61XX is possible A number of control messages are used for this communication The CU 61xx can read the following info from the AO 6004 By using SW 6000 the user can control the following settings in the AO 6004 through the CU 6105 CU6110 T ceimnaddeadanate Channel number for each output channel T T AEE E T Volume setting for each channel The settings can only be read or controlled from SW 6000 Specifications are subject to change without notice 11 DCS 6000 Digital Conference System Connection Details DCS LAN Chain The DCS 6000 system uses shielded Cat5e Cat6 or Cat7 F UTP or U FTP cables with shielded RJ45 connectors EIA 568 B wiring shall be used Important The names of Cat5 6 7 cable type have changed F UTP Important Use only F UTP or U FTP shielded cables and shielded RJ45 connectors and not U UTP cable which are unshielded Accessories Cat5e Connection Cables AWG24 BC G00 THO wetesesdeecescauts Connection Cable 0 5 m EC 6001 01 ciesiesivaiuanenmainins Connection Cable 1 m EC OD0T 02 sirppi Connection Cable 2 m BC GODT 03 raserer Connection Cable 5 m User Manual How to wire a Cat5e EIA 568 B cable to a RJ45 Function Connector 1 Connector 2 ORG WHT ORG WHT Pin a 2 3 4 Jo
2. SHURE LEGENDARY PERFORMANCE Conferencing and Discussion Systems AO 6004 Audio Output USER GUIDE 2015 Shure Incorporated User Manual AO 6004 rev C docx DCS 6000 Digital Conference System User Manual Table of Contents Table of Contents cccsceeceseeceeeuceeeeeeeeueees 2 General description ax ivacvness se teen tiuningo 7 LIMpOrtant cecceeceeceeccecceceeceeceueeuseuseeseeeees 3 FEACTUSES oo cee eeee eee eee cece eee ee eens neta eeeeeeeenees Installation precautions 0 sscceeeeeee 3 User controls indications amp connections 8 Cleaning srnca 3 SYSTEM SEtt NgS sesssssrrrrrrrrrrerrrrnrrnnn 8 Repackingospo 3 Normal operation 0 0 8 Warranty citccesiccsccescerticesieccinuscericeesivecess 4 System Setup sssssssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 9 Your DCS 6000 Conference System E 8 Jas 5 General guidelines PTETTIUCTITCTIOLIT LTT 9 The DCS 6000 system cccceescceeseeeeeeeess 5 Typical Schematics sccsssceseeeseeeseeeneeens 10 System COMPONENtS cceecceeceeeeeeeeeeeeees 6 Using AO 6004 with DT 60xx Digital IR TRANSMICGR sveactnitccacecnstcicendecesansaecssenis 10 Central equipment etC cccceeeeeeeeeeeeeees 6 Technical SpecificatiOnS cccccccccceennnnnes 11 Interpreter CQuiIPMENL viseciicviawnesirserinctias 6 Cari ARGRES UNITS BAG Cieee or ects 6 System Specification cccssssssseeeeeeenees 11 Rieacenrae 6 Connection Details cccccnnnseseeccennnnees 12 Operating ins
3. e with two built in channel selectors DM 6680 P Conference Unit portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DC 6120 P DC 6190 P DM 6620 F CM DM 6680 F MU 6040 C D MU 6042 D DV 6501 F AM 6040 CS 6340 FV FH Accessories User Manual Conference Unit flush mounted with Chip card and 5 voting buttons Conference Unit flush mounted with one built in channel selector Chip card and 5 voting buttons Microphone Unit for use with FD FC front plate with Loudspeaker Microphone and Buttons Available in Delegate D and Chairman C version Dual Microphone Unit for use with FD FC front plate with Loudspeaker Microphone and two delegate Buttons Voting Unit Ambient Microphone Unit Channel Selector flush mounted In addition to the unit a number of accessories are available like Storage Boxes GM 6523 Gooseneck Microphone 40 cm GM 6524 Gooseneck Microphone 50 cm GM 6525 Gooseneck Microphone 63 cm DH 6021 Delegate Headphone DH 6223 Stethoscope Headphone DH 6225 Ear Clip Headphone For detailed instruction in how to use the above units please refer to the User Manuals for the relevant products DCS 6000 Digital Conference System Operating instructions AO 6004 Audio Output Unit General description The AO 6004 Audio Output Unit for the DCS 6000 system enables the user to record the sound from a number of interpreted language channels or
4. e SW 6000 DCS 6000 Digital Conference System system Setup General guidelines Connect the AO 6004 to the various units using Cat 5 FTP or STP cables Please observe the following guide lines e Maximum cable length in one chain is 200 m without repeater This includes interconnection cables between the units The max usable cable length depends on the units connected and length of feeding cables etc User Manual Maximum cable length in one chain when using repeaters is 650 m If the last unit in one chain is a CS 6032 Channel Selector this unit has to be terminated with an external termination as the CS 6032 does not have an internal termination DCS 6000 Digital Conference System Typical schematics Connect the AO 6004 to the DCS 6000 network using Cat 5 cables The Analog Audio output connectors are connected to either tape recorders Ch 4 Ch 5 Ch 6 and Ch 7 Floor Ch 1 Ch 2 and Ch 3 lig Out A D DCS LAN DCS LAN 0 Chairman Central Unit Interpreter m m i Digital Transmitter beeee User Manual for recording the interpreted channels or to a DT 6008 Infrared Transmitter for transmitting the interpreted channels wireless IR Radiator Digital Receivers oe oe Q Delegate Delegate Delegate Delegate ON E To other interpreter booth Interpreter Using AO 6004 with DT 60xx Digital IR Transmitter When using the AO 6004 with the DT 60xx Infrared T
5. floor channel on external devices such as tape or hard disk recorders by Analog interface It can also be used to distribute sound channels to for example infrared distribution or loudspeaker system Features e Decoding of 4 language channels into analog audio chosen out of the possible 31 digital channels as well as the Floor channel in 3 qualities e The 4 decoded channels are available on 4 analog outputs XLR connectors transformer balanced User Manual A number of AO 6004 can be combined to decode more channels Up to 20 pieces AO 6004 can be connected and configured in one system to decode more channels Easy to use with preconfigured settings and automatic channel assignment at start up Output A channel O Floor Output B channel 1 Output C channel 2 Output D channel 3 The unit is connected to the DCS LAN as any other unit and by controlling it from the CU 6105 CU6110 it can be placed anywhere in the system The unit can be used as a single unit installed in a 19 rack or inserted in a slot in the CU 6005 DCS 6000 Digital Conference System User controls indications amp connections Front plate layout User Manual The front plate layout of the AO 6004 Audio Output Unit consists of 4 XLR Analog transformer balanced outputs and 2 DCS LAN connectors Danish Design amp Quality Made in Thailand lt 8 Output D 3 AO 6004 Back Panel Front plate controls and indicators T
6. he AO 6004 is an easy to use AO unit with pre configured settings and no user interface in terms of controls display or indicators Front plate connectors Audio Output A to D On the front are located 4 XLR 3P connectors each Supplying transformer balanced audio signal from each of the 4 channels The outputs can be used for tape recording purpose i e or for connecting a Digital infrared transmitter like DT 6008 DT 6032 or an Analog infrared transmitter for wireless transmission of the interpreted languages DCS LAN connector Two RJ45 sockets are located at the front of the unit for connecting to the previous unit like the CU 6105 CU6110 Central Unit or any other unit with a DCS LAN connector and to the next unit like an IS 6132 Interpreter Unit CS 6340 Channel Selector DM CM 6xxx Conference Unit System settings Pre configured settings The AO 6004 comes with pre configured settings and can be used without additional configurations The AO 6004 automatically assigns channels to the outputs at start up Output A is assigned channel O Floor Output B is assigned channel 1 Output C is assigned channel 2 and Output D is assigned channel 3 The output volume for each channel is 3 dB which is the recommended level for connecting to DT 60xx The unit can be re configured using SW 6000 The settings for a reconfigured unit can be saved in the CU 6105 CU6110 Output C 2 Analog Audio Outputs AO 6004 Audio Outp
7. jew 5 6 7 con BLU WHT BLU WHT 7 BRN WHT BRN WHT a a Important If other color codes are used then the four pairs are connected as follows Pair 2 Pinl amp 2 Pair 3 Pin3 amp 6 Pair 1 Pin4 amp 5 Pair 4 Pin7 amp 8 The phase of the pairs must be correct and the wiring spec as stated in Cat5e EIA 568 B have to be followed Note Cat6 and Cat7 cables can normally only be terminated in sockets female and not in cable plugs Cat6 and Cat7 can thus only be used for feeding cables terminating in wall outlets or patch panels EC 6001 10 ieee eee ee eeee Connection Cable 10 m EC GO01S20 xcccsieceetecedeias Connection Cable 20 m EC 6001 50 Lie ceececceceecaes Connection Cable 50 m 12 SHURE LEGENDARY PERFORMANCE www shure com United States Canada Latin America Caribbean Shure Incorporated 5800 West Touhy Avenue Niles IL 60714 4608 USA Phone 1 847 600 2000 Fax 1 847 600 1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email info shure de Asia Pacific Shure Asia Limited 22 F 625 King s Road North Point Island East Hong Kong Phone 852 2893 4290 Fax 852 2893 4055 Email info shure com hk
8. ransmitter the audio output level on the AO 6004 has to be set to match the sensitivity on the transmitter The correct level on each connected channel on the AO 6004 is 3dB This level is factory preset but can as earlier mentioned be changed using SW 6000 Please refer to the section Pre configured settings on page 8 The DT 60XX input level settings should be set to 6dB 10 DCS 6000 Digital Conference System Technical Specifications System Specification Digital Section Sound quality 20 bit audio 32 kHz sampling frequency Analog Section Output signal type ground lifting transformer balanced Nominal output level 0 dBm at nominal input Max Output level neraet a aa 15 dBm Frequency reSpOnNnSe ssssrerssnasnensanennsnannn 125 15kHz Signal tO noise ratio s sssssssssssssssrsrersnens gt 85 dBA Total harmonic distortion assssssccsecceerress lt 0 1 General Power requirement ssssssrerssnansenssnennsnans 24 48 V DC Power CONSUMPTION ssssssssssssssssrsrenenas 2W maximum Power supplied from PEPATE EATE CU 61xx EX 6010 PS 6000 Temperature to guarantee specified performance TE 5 Deg C to 40 Deg C 35 to 80 humidity Storage temperature E 20 Deg C to 60 Deg C 10 to 80 humidity Weight arara onn e a N lars 0 84 kg Dimensions W x H x D 180 205 x 38 x 120 120 mm Dimensions in brackets are including brackets Connectors DCS LAN loop through
9. rovided by SW 6000 software package running on PC The SW 6000 is an optional software package which expands the functionality of the DCS 6000 system The software runs on standard computer technology Standard PC with Windows 7 Server 2008 etc Main features of the SW 6000 are e Microphone management e Mimic panel operation e Interpretation management e Voting management e Message handling e Agenda handling e Data stored on SQL data base e Web service interface available for easy links to external applications e Multi language user interfaces e Supports different User types with different priorities user interfaces and control possibilities DCS 6000 Digital Conference System System components Central equipment etc CU 6105 Central Unit CU 6110 Central Unit EX 6010 Extension Unit PS 6001 DCS LAN Power Kit consisting of one PS CU and one PI 6000 PS CU Power Supply PI 6000 DCS LAN Power Inserter RC 6000 Redundancy Controller AO 6004 Audio Output Unit AO 6008 Audio Output Unit RP 6004 Repeater for four chains JB 6104 Junction Box with 4 outputs Interpreter equipment IS 6132 P LS 6132 P Interpreter Unit Interpreter Loudspeaker Conference units and Ch selectors DC 6990 P Conference Unit portable with touch screen with two built in channel selector Chip card and 5 voting buttons configurable as Delegate Dual Delegate or Chairman Conference Unit portable Conference Unit portabl
10. s original condition periodically clean it with a soft cloth Stubborn stains may be removed with a cloth lightly Repacking Save the original shipping cardboard box and packing material they will become handy if you ever have to ship the unit For maximum protection User Manual To avoid moisture condensations do not install the unit where the temperature may rise rapidly pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver e Connect the equipment to an outlet on a circuit different from that to which the e receiver is connected e Consult the dealer or an experienced radio TV technician for help dampened with a mild detergent solution Never use organic solvents such as thinners or abrasi
11. system offering interpretation language distribution conference microphone and voting facilities with attendance check with Chip Card e Digital transmission of audio from to the Conference unit to from the central unit using a unique digital DATA and AUDIO bus named DCS LAN e Control of up to 3800 conference units This number does not include Channel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system e Delegate and Interpreter units are powered and controlled by the CU 61xx Central Unit which drives up to app 50 units with the PS CU power Supply e EX 6010 Extension Unit or PS 6001 DCS LAN Power Kit is available if more units are required e Delayed switching on of power to the two DCS LAN chains to minimize the total in rush current on the Mains supply e Designed for 31 interpretation channels and 8 open microphones e Audio scrambling of the audio to avoid eavesdropping e Designed in a standard 1HE 19 cabinet e TCP IP connection on CU 61xx for external operation of the system using a PC or control system such as AMX or Crestron e Functionality on the CU 61xx depends on the Feature License uploaded into the unit e Firmware in Delegate units Interpreter Units Central Units etc is upgradeable e Operated either stand alone or from a PC using the CU browser or using SW 6000 software e Added functionality and comprehensive features p
12. tructionS scssssssssseseeseees 7 ACCESSOPIECS siisesrretcisccnsedecutnetrivenserecunava 12 AO 6004 Audio Output Unit 00085 7 2015 Shure Incorporated User Manual AO 6004 rev C docx DIS Digital Conference System Important Installation precautions Do not install the unit in a location near heat sources such as radiators or air ducts or in a place exposed to direct sunlight excessive dust or humidity mechanical vibration or shock Compliance The equipment is intended to be used in professional audio applications Note This device is not intended to be connected directly to a public internet network EMC conformance to Environment E2 Commercial and Light Industrial Testing is based on the use of supplied and recommended cable types The use of other than shielded screened cable types may degrade EMC performance Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate this equipment This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada Authorized under the verification provision of FCC Part 15B Please follow your regional recycling scheme for batteries packaging and electronic waste Information to the user This equipment has been tested and found to comply with the limits for a Class B digital device Cleaning To keep the cabinet in it
13. ut Output B 1 Output A 0 SW6000 settings The SW6000 can be used for changing the assignment of channels to outputs and for setting the volume Both the Conference Administration Application CAA and the Conference User Application CUA can be used to configure the AO units connected They both have settings for assigning channels to each of the 4 outputs A D Each output can be set to one of the 31 language channels or one of the three Floor channels Floor automatic gain controlled output Floor 1 loudspeaker unregulated audio Floor 2 loudspeaker regulated audio An ambient microphone will only be active on the Floor channel not on Floor 1 or Floor 2 Values Floor 2 Floor 1 Floor 1 30 31 The volume of the outputs can also be set if the default settings are not appropriate Values Off 40 39 14 15 Refer to the CAA and CUA User Manuals for more details Normal operation Powering up Connect the AO unit s to the rest of the system via the DCS LAN connectors and connect the audio outputs to the appropriate units tape recorders infrared transmitters etc Switch on the power on the Central Unit During the initialization the AO unit will automatically assign channels to the outputs The unit is immediately ready to use after start up unless other channels need to be assigned to the outputs or the channel volume needs to be adjusted These adjustments can only be done using th
14. ve cleaners since these will damage the cabinet re pack the unit as originally packed from the factory DIS Digital Conference System Warranty The individual units in the DCS 6000 system are minimum covered by 24 months warranty against defects in materials or workmanship User Manual DCS 6000 Digital Conference System User Manual Your DCS 6000 Conference System The DCS 6000 system DCS 6000 Digital Conference System is a system to be used at meetings where a number of people are addressing the Floor in a structured manor The audio from the Conference units can be heard in the built in loudspeakers in the units The system does also allow for simultaneous interpretation for international conferences where multiple languages are used To enable all participants to understand the proceedings interpreters can simultaneously translate the speaker s language as required These interpretations are distributed through the connected Conference units and delegates can select the language of their choice and listen to it through headphones DCS 6000 Digital Conference System comprises of one CU 61xx Central Unit and a number of Conference Units Gooseneck Microphones and other accessories depending on the system configuration The DCS 6000 system has the following main features e Fully digital e Excellent sound quality e State of the Art fully digital integrated interpretation discussion and voting