Home

NDC-B052 Access Control Panel

image

Contents

1. power inputs fuses from alternating current source http www itvsystems com ua Integrated Technical Vision Ltd 13 Control Panel Operation Control Panel Operation Control panels are supplied unloaded without expansion modules It is necessary that you should connect expansion modules readers and other devices to NDC B052 to organize security and access control system Besides you should download the panel using Golden Gate software Panel can control up to 64 independent access points Each access point may be in one of four modes main mode alarm blocked or free pass Free pass mode has the highest priority as the panel switches to this mode in case of fire then go blocked alarm and main modes Main Mode The controller grants or denies access to cardholders in this mode In the Main mode reader LEDs blink red Access with ID To access the premises cardholder passes identificator to the reader If it is valid the panel grants access unlocks the door and green LED switches on Access with ID and PIN To access the premises cardholder passes ID to the reader The panel checks the necessity of PIN entering and if it is necessary LED blinks yellow that means PIN entry is awaited After valid PIN entry door is unlocked and reader LED lights green Using RTE To go out of the premises with a single sided door user must depress press amp release Request to Exit button Reader LED lights green Access Denial Acces
2. Outputs One 5A 24 V relay Two open drain outputs 0 5 A 12V with multifuse protection e Networking RS485 interface Input Voltage 10 15 VDC Voltage ripple 500 mV 12V e Power consumption Standby current 100 MA 12V e Maximal current 180 MA 12V http www itvsystems com ua Integrated Technical Vision Ltd 7 Specifications Environmental requirements Operation temperature Relative Humidity Physical dimensions e Width Height Depth e Weight Nonerasable memory Identificators e Weekly schedules e Time zones Holidays Events 8 Integrated Technical Vision Ltd 0 C 55 C 80 relative at 35 C 300mm 310mm 80mm 2 45 kG up to 20 000 up to 255 up to 255 up to 255 up to 80 000 http www itvsystems com ua Terms Terms Access point Access point is a logical concept of access control system implying control of passing through a door in one direction It consists of reader access control panel or it s part door supervision devices like magnetic sensor RTE etc and door locking device For instance turnstile with two way passes has two Access points one for entrance and the other one for exit door of this type is called double sided door Door with a reader on one side has only one Access point Entry point and it is called single sided door Antipassback Antipassback function is implemented in NDC B052 access control panel to prevent the situation whe
3. PSU 1 5 power supply unit with battery backup manufactured by ITV Ltd use is recommended This power supply unit provides 12V power rated at 1 5A The 7AH battery may be used in it PSU 1 5 has outputs for power and NDC B052 Batt d battery status indication 3 arery goo O Operating voltage range is 10 8V 15V Maximal permissible g Power good voltage is 16V a fa GND z 0 gt 12V N bag Supply unit AC http www itvsystems com ua Integrated Technical Vision Ltd 21 Limited Warranty Limited Warranty 22 Integrated Technical Vision Ltd warrants that for a period of eighteen months from the date of purchase the product shall be free of defect in materials and workman ship under normal use and that in fulfillment of any breach of such warranty Integrated Technical Vision Ltd shall at its option repair or replace the defective equipment upon return of the equipment to its repair depot This warranty applies only to defects in parts and workmanship and not damaged incurred in shipping or handing or damaged due to causes beyond the control of Integrated Technical Vision Ltd such as lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be lieu of any and all other warranties whether expressed or implied and of all oth
4. access control panel to take instruction courses conducted by the company Technical support for all products of Integrated Technical Vision Ltd can be obtained at business time by the phones below 380 0 44 248 65 88 380 0 44 248 65 89 380 0 44 248 65 90 This support assumes the calls of trained specialists End users must apply to their dealers or installers before phoning us This information is available on our web site www itvsystems com ua http www itvsystems com ua Integrated Technical Vision Ltd 3 Integrated Technical Vision Ltd http www itvsystems com ua Contents Preface u rilanci alanleda ai alai 7 Features cala Ei dee 7 Specifications s er aar n iaia 7 AEE AAEE EEE EA A A HETE 9 General Configuration iii 11 Wiring Gonfigurations nela e ia 12 Controls and connections on board 13 Control Panel Operation i 14 Mall Mode daa toda ti rail nl ni sei aaa eS ale tah ears 14 Alarm MOOG sro did 14 Free Pass Mode nia iaia elia pavia ia lei 15 Blocked MOC Ge cere tiri rare ia a ira at 15 Mounungi Rolli 15 RS 485 Interface iii 16 RS 232 Interface iitraiiaa da 17 Ethernet Ports lirici a Eo ae la 17 Setting id and IP Address arden 18 Resetting hardware to factory defaults 21 Power Supply WING irc ria 21 Limited Warranty usada rilanciata 22 Index 24 http www itvsystem
5. activates outputs assigned for BELL and ALARM Alarm output is deactivated when panel switches into the mode different to alarm mode and BELL output is deactivated after the programmed time If access point is in the alarm mode passing through this point is prohibited RTE button unlocks the door Pass the ID with Alarm OFF sign to switch alarm mode off or do it with command from computer Free Pass Mode Sometimes the situations arise when a door should be open for free pass to everyone e g in case of fire earth quake or any other disaster In such cases the panel switches to the Free Pass mode In this mode reader LED blinks green and yellow alternately Access point switches into the Free Pass mode with the operator command or if the input programmed as Free Pass is broken Access point is in Free Pass Mode until this input is shorted or the operator cancels the mode While Access point is in Free Pass mode locking device is locked and the panel does not respond to IDs passing PIN entry or RTE button pressing The control panel allows you assigning of Blocking function to an input for one access point A B or two access points together A B Blocked Mode The Blocked Mode is designated for situations when access to the premises should be prohibited to everyone in case of security alarm for instance When Access point is in the Blocked mode access is granted only to cardholders of IDs with Security Service sign
6. be used for RS 485 wiring For maximal range of 1200 meters please use 0 4 mm 2 cross section wire 0 2 mm 2 cross section wire will provide the range of 500 meters On the first and last panel in the drop line short jumpers JP5 JP6 for the first port and JP7 JP8 for the second port to add the resistive load Take care of proper grounding of all panels in the network Setting jumpers in expansion modules bus connected to the first serial port RS485 NTC LNET RS485 16 Integrated Technical Vision Ltd http www itvsystems com ua Mounting Setting jumpers in panels bus connected to the second serial port Jumpers are set RS485 NDC B052 RS485 RS 232 Interface First consecutive serial port has also RS 232 bus receiver transmitter DB9 jack in addition to RS485 bus receiver transmitter NDC B052 access control panel can be connected to PC straight via null modem cable or modem using this output Ethernet Port The NDC B052 access control panel is provided with UTP jack for Ethernet connec tion UDP protocol is supported http www itvsystems com ua Integrated Technical Vision Ltd 17 Setting id and IP Address Setting id and IP Address All panels in RS 485 drop line are connected consecutively They should have unique number id for their joint operation It is also necessary that you should set IP address and subnet mask for local net operation Address subnet and id settings for RS485 drop line
7. B052 with front cover off http www itvsystems com ua Integrated Technical Vision Ltd 11 Wiring Configurations Wiring Configurations 600000900009 9909805558 NANA RS485 RS485 RS232 sue lios Ethernet BA Se A or Other NDC B052 Diagram2 Integrated Technical Vision Ltd modem http www itvsystems com ua Wiring Configurations Controls and connections on board Terminals assignment Terminal Function Description 9V 9V 9 V power connection 12V 12 V 12 V power connection GND GND IUT 12 RSA Fist RS485 por 1B RS485 B GND GND 2UT 12 RS485 2A RS485 A Second RS485 port 2B RS485 B GND GND COM Common NO aida Relay contacts ci eee Power and battery status control intputs PWG Power good TMP Tamper m GND GND mper contact connection GPI General Purpouse Input Programmable intput Jumpers and LEDs SW1 Panel Reset button JP5 JP6 JP7 and JP8 jumpers for RS485 load connection JP3 programming and resetting LED1 switches on at FUSE1 blow LED2 switches on at relay output activating LED3 1 port indicator indicates TX with red light and RX with green light LED4 2 port indicator indicates TX with red light and RX with green light LEDS power indicator FUSEs FUSE1 power supply output fuse FUSE2 power input fuse from direct current source FUSE3 and FUSE4
8. Door cannot be unlocked with RTE button Reader LED blinks red and yellow alternately during Blocked mode time Access point switches into the Blocked mode with operator command or when the input programmed as Blocking is broken Access point remains in the blocked mode until this input is shorted or the operator cancels the mode The control panel allows you assigning of Blocking function to an input for one access point A B or two access points together A B http www itvsystems com ua Integrated Technical Vision Ltd 15 Mounting Mounting NDC B052 is supplied in a metal frame with the built in battery backup The access control panel is to be mounted in place easy to servicing To mount the panel on the wall proceeds as follows open the front cover mark places for fixing holes using the back plate as a template pass the wires through the holes on a back plate fasten the frame connect the wires RS 485 Interface NDC B052 has two serial ports with RS485 bus m m o DaDa receiver transmitters First port GND 1UT AR ELELELTL 1A 1B contacts is intended for PC connec tion Second port GND 2UT 1A 1B con tacts is intended for expansion modules and subordinate panels connection The range of RS 485 bus is up to 1200 meters The number of panels or expansion modules is up to 32 RS 485 port is protected against overvoltage 60V and cross polarization Unshielded four wire cable may
9. NDC B052 Access Control Panel Installation Manual ACCESS CONTROL PANEL Integrated Technical Vision Ltd http www itvsystems com ua This manual covers installation programming and utilization of NDC B052 access control panel Read this manual carefully prior to installing and program ming the unit Design Change Disclaimer Information due to design changes and product improvements in this manual is the subject to change without notice ITV reserves the right to change the product design any time that will subsequently affect the contents of this manual ITV assumes no responsibility for any mistakes that can appear in the manual The company guarantees that this Installation Manual is up to date and corresponds with the unit you purchase Reproduction Disclaimer All rights to this document are preserved by Integrated Technical Vision Ltd Copying printing and any other kind of unauthorised reproduction of this document or a part of it is prohibited Trademarks ITV is a registed trademark of Integrated Technical Vision Ltd Training and technical support Integrated Technical Vision Ltd performs training on the installation program ming and utilisation of NDC B052 access control panel For detailed information about training and discussing of your particular requirements to the unit please contact our personnel by the phone numbers below It is recommended for the staff intended for sales and installation of NDC B052
10. are executed using PC connected to the first port DB9 jack with null modem cable Switch off the power set JP3 jumper connect null modem cable to DB9 jack see Diagram 2 Switch on the power of the panel within 40 seconds the panel switches to the main mode In process of launching LED4 blinks and then switches off Now start ggipcfg exe program Choose Action gt Search hardware menu items and press dA button Search of devices will be executed on all COM ports In the bottom part of program window the result of search will be displayed Data exchange between PC and NDC B052 during search will be seen on blinking of LEDA actien Configure device Alt E OY Export configuration fram registry Alt E Ext If the controller controllers are not found out by the program repeat search Observe that during search LED3 is not blinking Hesult T Searching hardware Done 31 When a control panel panels is found select the necessary COM port and controllers ID in Hardware panel In Configuration parameters the current configu ration of the control panel is displayed 18 Integrated Technical Vision Ltd http www itvsystems com ua Setting id and IP Address bal 4042 Conger then Utility Fut mT IP sos CE Current Id EP sl Subrest Hark rs 250 Completed Found 0 descelil Choose necessary configuration changes and load them to the controller To do this select Actions gt Configure d
11. er obligations or liabilities on the part of Integrated Technical Vision Ltd This warranty contains the entire warranty Integrated Technical Vision Ltd neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for it any warranty or liability concerning this product In no event shall Integrated Technical Vision Ltd be liable for any direct indirect or consequential damages Loss of anticipated profits loss of time or any other losses incurred by the buyer in connection with the purchase installation or operation or failure of this product Integrated Technical Vision Ltd http www itvsystems com ua http www itvsystems com ua Integrated Technical Vision Ltd 23 Index A Access access denial 14 access point 9 access with ID 14 access with ID and PIN 14 antipassback 9 B Battery battery backup 7 11 battery backup PCB 11 battery status control 7 E Ethernet port 17 Events 8 F FUSEs 13 G Global Antipassback 7 9 H Holidays 8 I Id and IP Address 17 Idendificators 8 access with ID 14 access with ID and PIN 14 proximity identificator 10 Interface RS 232 interface 17 RS 485 interface 16 J Jumpers 13 L LEDs 13 M 24 Integrated Technical Vision Ltd Memory flash memory 7 nonerasable memory 8 Modes alarm mode 14 blocked mode 15 free pass mode 15 main mode 14 O Operation temperature 7 Outputs relay 7 terminals assignment 7 transist
12. evice menu items and press button a Bee BA Search hardware bi Export configuration from registry AIHE l Exit In the bottom part of program window result of loading will be displayed If testing of device passed successfully and loading is not executed the message Con figuration is not loaded controller is in operation mode appears which means JP4 crosspiece is not set Set the crosspiece and repeat actions on configuration loading If loading of the controller controllers is executed on the computer where Golden Gate software is not installed it will be necessary to export the data about controller controllers configuration or http www itvsystems com ua Integrated Technical Vision Ltd 19 Setting id and IP Address Action dA Search hardware g Configure device Export configuration From registry Ak E Ext press i button transfer obtained reg file to the PC with installed Golden Gate program and execute merge to system registry 20 Integrated Technical Vision Ltd http www itvsystems com ua Resetting hardware to factory defaults Resetting hardware to factory defaults Set JP3 jumper when power is off Short two left XP1 contacts Switch on the panel power Switch off the power and take off both jumpers The panel switches into unloaded state all settings and tables are deleted After resettling to factory O defaults panel s id is set to 0 value Power Supply Wiring
13. n user gives his ID to another person after passing to the premises If this function is on NDC B052 tracks an ID position Inside or Outside the premises On any attempt to pass in the same direction twice NDC B052 denies access and stores Access Denied Antipassback event into the Log Antipassback function can be set on only in case of double sided door control Global Antipassback This function is similar to local Antipassback but it works at several access points simultaneously All access points should be consolidated in a group for Global Antipassback function application Code matching NDC B052 can arise alarm in case of attempt of code or ID matching Code matching is considered when invalid code or ID is entered several times Valid code entrance clears the counter This function switching on and number of code entries can be programmed on PC Door Sensor In access control systems various sensors are used to control door status opened or closed magnetic door sensor sensor of the turnstile rotor position inductive sensor of car passing through the road barrier etc Door Contact terminal of NDC B052 is intended for connection of these sensors Door time If door sensor is open corresponding access switches goes into alarm mode Alarm is not invoked if the sensor is opened during Door Time This interval starts when access is granted and lasts for the programmed time or terminates on break and subsequent sh
14. or 7 P Physical Dimensions 8 PIN 9 access with ID and PIN 14 Power power consumption 7 power supply wiring 18 R RS 232 17 RS 485 16 RTE 10 using RTE 14 S Schedules 10 weekly schedules 8 T Tamper 7 Terminals assignment 13 http www itvsystems com ua 071004
15. ortening of the door sensor Downloading NDC B052 is to be downloaded after setting all parameters modes of inputs outputs access rights and others on PC During downloading parameters are rewritten into the access control panel If you change control panel parameters in your computer they will not take effect until these parameters are downloaded into the panel PIN Personal Identification Number Some readers have built in keypad The keypad may be used for PIN Personal Identification Number entry in this case It can be both self dependant or used as http www itvsystems com ua Integrated Technical Vision Ltd 9 Terms an additional code after ID passing When PIN is programmed as the additional code NDC B052 waits for PIN entry after card passing Proximity Identificator In access control systems each user has ID identificator with the unique code Proximity IDs may be in shape of plastic card key trinket etc Reader Readers are devices assigned for reading information from IDs and transmitting it to the control panel There are several types of IDs and readers for them Watch that reader and control panel use the same interface NDC B052 utilizes Wiegand interface RTE Request to Exit To exit from the premises with a single sided door the button wired to the control panel is used This button is called RTE Request To Exit button If someone opens the door otherwise than pressing RTE button by re ene
16. rgizing locking device opening lock with a key etc the Door Forced Open event arises RTE button may be used for remote door opening as well Schedules NDC B052 is capable to store up to 255 time zones 255 week schedules and 255 holidays Moreover NDC B052 can store several floating schedules based on a period different to a week The number of such floating schedules depends on the period length Several IDs access To access the high security premises the presence of more than one person may be required NDC B052 allows assigning of up to 15 groups of people with access rights The access is granted only in case when one person from each group is present For instance you have the room which can be attended only by the personnel of R amp D department escorted with guard You can form two groups for this access group of R amp D employees and group of guards The access is granted if two IDs from different groups are passed to the reader one belongs to R amp D department employee and the other one to a guardian Integrated Technical Vision Ltd http www itvsystems com ua General Configuration General Configuration The layout of NDC B052 is shown on Diagram1 below m m m i m m m 1 battery backup PCB 2 terminal block with safety fuse 3 220V 50Gz transformer 4 panel PCB 5 battery Diagram1 General view of NDC
17. s com ua Integrated Technical Vision Ltd 5 Integrated Technical Vision Ltd http www itvsystems com ua Preface Preface Primary goals of Access Control System are identification of a person confirmation or not confirmation of access control of movements in the necessary zone It can provide time and attendance logging in addition to usual task of restricting individuals access to certain areas All users access information is gathered by the server where administrators can retrieve and analyze it This data provides recording of staff movement within an organization whether it is a small company or company that employs thousands The NDC B052 access control panel is designated for sophisticated access control and creation of security systems with many access and monitor points The panel can control up to 64 access points All access points are attached to NDC B052 via expansion modules using RS485 bus Up to 32 modules can be connected to the control panel Features e Supports all Wiegand reader technologies Distributed database for independent operation Operates in remote site configurations with dial up Card PIN or card and PIN access support e On board lithium battery for data storage 4 wire RS 485 RS232 Ethernet Tamper alarm Battery status control 1FormC relay e 1 MB static RAM with battery backup 0 5 MB Flash memory e Global antipassback function Built in buzzer Specifications
18. s may be denied by the following reasons Panel is not downloaded reader LED does not light or blink ID is not registered reader red LED and buzzer switch on for a second ID time has expired reader red LED and buzzer switch on for a second Access is prohibited at present moment according to a schedule reader red LED and buzzer switch on for a second Attempt of code matching if the function is switched during programming Attempt of passing in the same direction twice reader red LED and buzzer switch on for a second if Antipassback function is on Lost or blocked ID is passed reader red LED and buzzer switch on for a second Panel is in the Alarm mode red LED lights uninterruptedly Panel is in the Blocked mode red LED lights uninterruptedly Alarm Mode In the alarm mode reader LEDs light red constantly Access point switches into alarm mode for the following reasons In case of door ajar Attempt of access with lost ID 14 Integrated Technical Vision Ltd http www itvsystems com ua Control Panel Operation Door is opened too long door time expired Attempt of code matching if the function is switched on during programming Alarm output is activated but the mode does not switch on in case of panel box tampering attempt You can disable control panel switching into Alarm mode in case of Door opened too long event the inhibition is set for each access point separately ea In alarm mode panel

Download Pdf Manuals

image

Related Search

Related Contents

Wireless Audio with Dock  Transportable LIBS Workstation User's Manual  Sunbeam 078505-101-000 Instruction Manual  dreamGEAR Neo Fit  

Copyright © All rights reserved.