1. SMARTFiber Pro Fiber Optic Power Meter for Wavelength 850 1300 1310 1490 1550 1625 User Manual Model No 25 835Pro f x r lc INNOVATION Introduction Features Product description Accessories Key definition Specification Instructions for operation 3 1 TEST MODE 3 2 RECORD MODE 3 3 BROWSE MODE 3 4 SET MODE 3 5 ZERO MODE 3 6 LIMIT MODE Instructions for battery Driver installation Maintenance Storage conditions Warranty 03 04 05 06 07 08 09 10 13 17 19 20 23 27 27 43 43 43 Introduction The Optical Power Meter is a high accuracy optical power measurement tool It tests dynamic range of optical power from 3 to 60dBm with six calibrated wavelengths 850nm 1300nm 1310nm 1490nm 1550nm and 1625nm With Hobbes Optical Power Meter it displays a pass or fail result according to the threshold the user has defined It also has the capability to identify modulate signals 270Hz 1KHz 2KHz simultaneously by the power source for identification purposes For fast and easy operation in testing the corresponding wavelengths we recommend the Hobbes optical light source OPTIsource as a complete instrument in auto identifying wavelength of optical power source It utilizes an InGaAs detector for an improved sensitivity and temperature stability It also has the capacity to record up to 1000 test data that is up loadable to a PC via USB connection for easy and convenient report
2. Pro User manual 06 Key definition Marking On Off cancel Power button Cancel button Name Function 1 Press the button for a few seconds to power the unit on or off 2 When the power is on press the button to activate or deactivate auto off function 3 Cancel setting button return to test mode 1 Mode button 2 Backlight button 1 6 Selection modes TEST default mode RECO BROW SET ZERO LIMIT Mode 2 Press the button for a few seconds to activate or deactivate the backlight Wavelength selection button Wavelength selection for 850nm 1300nm 1310nm 1490nm 1550nm and 1625nm dBm W Unit selection button Optical power measurement in dB dBm Watt Increase the number Increase the number or letters Enter save edit Decrease the number Key operation execution Decrease the number or letters Selection or execution 07 Specifications Sensor type InGaAs Wavelength 850nm 1300nm 1310nm 1490nm 1550nm 1625nm Dynamic Range 3 to 60dBm Accuracy 0 15dB 1nW 1300nm 1310nm 1490nm 1550nm 0 25dB 1nW 850nm 1625nm Resolution 0 01dBm Unit dBm Watt dB Fiber connector Replacement type for FC ST SC Battery AA battery x 4 6V Dimension 202 8 x 107
3. purposes 03 Features e Portable high accuracy and dynamic power meter e Calibrated at 850nm 1300nm 1310nm 1490nm 1550nm and 1625nm e Relative and absolute power display e With self calibrated ZERO function e Ideal for both multi mode and single mode optical fibers e Identify modulate signals 270Hz 1KHz 2KHz for identification purposes e Automatic wavelength switching e Optional adapter to test both 2 5mm 1 25mm fiber cables e Battery low indicator and auto power shut off e 1000 data item storing and uploading e Pass fail indication by user defined threshold 04 NO 0 WDE Product description Replacement connector LCD display On Off cancel Mode backlight Wavelength dBm W Up GL G06 3907 om EE U ea LJ m FETE Omm EE ed Down Enter Save edit Rubber cover Battery holder Stand USB connector O5 Accessories Portable strap USB 2 0 cable Protective zipped bag with PU foam inside SC and ST connector Driver installation CD SMARTFiber
4. setting by user Press Up and Down to increase or decrease the character number 3 5 ZERO MODE Whenever the environmental conditions temperature humidity etc changes user may zero the unit for more accuracy User can clear the meter s memory to return to manufacturer s default settings Step 1 Press Mode button to select the ZERO mode and then press Enter button to enter the mode Step 2 Two submenus are in the mode CAL and CLEAR Use Up and Down button to choose the submenu 20 LAL Z En Auto off Note CAL menu in ZERO mode CAL menu Before CAL operation user need to cover fiber input port with dust protection cap Press Enter button to begin the zero CAL operation The LCD displays NULL for 2 seconds then return to CAL menu Press On Off button to cancel and return to the previous menu 21 NULL cm Auto off LLEHR Z cm Auto off Note CLEAR menu in ZERO mode CLEAR menu The menu is used for clear all memory data In the menu press Enter button to begin the clearing operation LCD displays MEM for clearing data item P F for clearing 22 threshold value REF for clearing dB measure ratio After clearing LCD displays CLEAR again Press On Off button to return to the previous menu 3 6 LIMIT MODE User can define threshold to specify acceptable power values When a threshold is activated the unit will indicate the te
5. atible optical laser light source Hobbes OPTISource Compatible optical laser light source simultaneously sends wavelength code along the fiber The meter can identify the code and switch to the corresponding wavelength avoiding manually changing the power meter wavelength OOO 000 agal OPTISource SMARTFiber Pro 26 Instructions for battery The SMARTFiber Pro displays a battery icon on the screen to indicate the battery status When the Low Battery icon flashes on the screen it is indicating that the battery status is low and need to be replaced Driver installation Steps 1 Insert the SMARTFiber Pro CD into the computer and press Next to start the installation ky SmartFiberPro Welcome to the SmartFiberPro Setup Wizard The installer will guide you through the steps required to install SmartFiberPro on your computer WARNING This computer program is protected by copyright law and intemational treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law 27 2 To install in this folder click Next To install in a different folder enter it below or click Browse ke SmartFiberPro Select Installation Fol
6. der The installer will install SmartFiberPro to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Eolder EProgram Files Hobbes SmartFiberPro Browse Disk Cost Install SmartFiberPro for yourself or for anyone who uses this computer C Everyone Justme cot cane 28 3 Click Next to start the installation B SmartFiberPro iz Confirm Installation The installer is ready to install SmartFiberPro on your computer Click Next to start the installation 29 4 The SMARTFiber Pro is being installed Installing SmartFiberPro SmartFiberPro is being installed Please wait 30 5 The SMARTFiber Pro has been installed Installation Complete SmartFiberPro has been successfully installed Click Clase to exit 31 6 After the driver has been installed connect SMARTFiber Pro with your computer through USB cable After device is connected please go to my computer and right click your mouse to choose manage Ej SmartFiberPro Owner Internet A My Documents E Internet Explorer J _ Emai E Tour Windows XP Manage Map Network Drive a SE OR Disconnect Network Drive Show on Desktop fa Notepad Rename Properties All Programs gt PQ Log orf tum off computer start W untitled Paint 32 7 In Computer Ma
7. driver CSST ES 35 10 While you istall it might shows a Hardware installation warning Click continue Anyway ih System Toole By Evert viewer gy Dared Folders H BB Performance Logs and Alerts Device Manager DEL D Removable Storage Dich Defragmenter Dick Management de gt Services and Agphcanons 2i Launches the Hardware Update Wizard for tr The software you ere inetalling for this hardware Hobbes Smart Fier Pro has net passed Windows Logo tasting to ts cont atiblty an wren Una hy Eu tur i AAT Continuing your inatallatsan of this sollware map ampan o dertataize the conect operation of yout system either immediately os in the future Microsoft strongly Wistart Y Saribas Pro os Pare 2 Computer Manageme 36 11 Hardware update is complete BY Fle Aten Ven Window Hep Omg Srna Computer Management Local Hardware Update Wiza a 3 nt ret Completing the Hardware Update 2 Wizard amp angs re Tha vazad hive fresha rt are the soiba bor enable tor aye DA Defragmenter Hobbes Sman Fiber Pro Dick Management me Bp Services and Agphcations Chek Forzh to chose te mad Launches the Hardware Update Wizard for th Biseart YY SA Trbee Pro 06 Pane E Computer Managere 37 12 On your desk top choose the SMARTFiber Pro icon istar IY Dwitrbae Pro 0 Pare GP smart ber Pro 38 13 In SMARTFiber Pro software choose update If you w
8. nagement please choose Device Manager from Universal Serial Bus Controllers Choose Hobbes SMARTFiber Pro and right click mouse to choose update driver Computer Management compu M Fle Action Ver Window Help OM FEC arna a GG WE ATA ATAPI controller 4 Sy MLL 1294 Bus host controllers 4 gt raybosrde a TY Mee and other panteg devices B Montons Universal Sena Dus controller amp Le irte R UWUIOUIOEM Usb 2 0 Lrhanced Host Controler 2c M iistart IY owatrberPro1 Pane 4P smart Fiar Pro E Computer Manageme CES 33 8 Windows will display Hardware Update wizard and choose install from a list or specific location Advanced By Fe Aten Ven Window Hep OM PSO arna Computer Management Local ib System Tooke Ei Event viewer Shared Folders H Performance Logs and Alerts Device Manager Borage e H p Services and Agphcatons 2i Lourches the Hardware Update Wizard for th istart Y avarrber Pro 00 Pane 2 Computer Manageme Thee wizard helpa you natal solima bor Hobbes Sanat Fiber Pro I your hardware came with an installation CD 2 o hoppy disk insert it now What do you wart the wizard to do natal the toltwate autematicaly Fecommendes Inata hom a bet or specific location Advanced Chek Newt to confine us CE _ cet 34 9 From search and installation options choose include this location in this search and browse your SMARTFiber Pro
9. ngth Note LCD displays current wavelength fiber ID power value 1 Current wavelength 2 Fiber ID or the number of Records 3 Power value in dBm 4 BROWSE Mode 17 Step 1 Press Mode button to select the BROWSE mode and then press Enter button to enter the mode Step 2 Press the Up and Down button to change the test results forward or backward Step 3 Pressing and Holding the Enter button a few seconds will delete the current record 300 nn 000 JEL B m Auto off Note The deleted record item can not be browsed 18 3 4 SET MODE In SET MODE user can set the cable name for references For example When saving the test results in TEST mode user can set the fiber ID and the cable name to be displayed when test result data are uploaded to a PC Step 1 Press Mode button and select the SET mode Then press Enter button to enter the mode Cable naming can be set up to 4 characters from O to 9 then to A to Z sequences Step 2 Press Up and Down button to increase decrease each character number Step 3 Press Enter button to begin next character setting Step 4 Press Enter button for a few seconds to save the setting When cable naming is incomplete the corresponding field will flash to indicate missing field Step 5 Press On Off buttons to return to previous menu 19 Note The default fiber name is
10. nter button to enter the mode In wavelength selection submenu pressing Up and Down button will change wavelength After selection pressing the On Off button will cancel the operation and return to previous menu 13 Set auto test time parameter Pressing the Enter buttons to increase or decrease the value parameter and sample frequency parameter 15 30 60 120 180 240 300 minutes is available default is 15 minutes Press On Off button to cancel the operation and return to previous menu 00 1 TIME Auto off Note The 0015 stands for 15 minutes It is test parameter 14 Set sample frequency parameter Press the Up and Down buttons to increase or decrease the value 5 10 15 20 30 60 seconds is available default is 5 seconds then press On Off button to cancel the operation and return to previous menu 0009 SHMP Auto off Note The 0005 stands for 5 seconds It is sample frequency parameter After setting press Enter button to start the auto test Then press the On Off button to stop the auto test 15 B ND Note LCD displays the remaining time It is 00 hour 14 minutes 23 seconds Hour Counting down automatically Minutes and Seconds Counting down automatically Testing automatically RECORD Mode 16 3 3 BROWSE MODE In the mode user can browse fiber ID power value and wavele
11. ould like to see your auto test result choose Auto Tests and click get data 39 40 14 If you would like to see your manual test result please go to Table and click upload From upload data choose manual Tests and click get data 41 15 Your manual test result has been uploaded 42 Maintenance Carefully check cleanliness of sensor surface Do not use nonstandard optical connectors and plugs with bad polished ends as it can damage the sensor surface Storage conditions From 30 to 60 C and humidity non condensing up to 95 at temperature 35 C Warranty The device is guaranteed for two years after completing the registration procedure from the date of original sale in Hobbes Group web site The manufacturer will repair the device free of charge if manufacturer determines the product failed due to manufacture defect This warranty is only valid if the device is used for its intended purposes only Manufacturers warranty is voided if the product has been tampered and damaged from misused 43 INNOVATION
12. st result pass or fail If the current power value is more than the threshold the meter indicates Pass Otherwise Fail For example The threshold is 46 97dBm the power value is 60 76 the meter indicates fail Step 1 Press Mode button to select the LIMIT mode and then press Enter button to enter the mode Step 2 In LIMIT MODE 3 information s will be displayed on the screen First line indicates the current wavelength Second line indicates the threshold Third line indicates P F for pass fail 23 B50 on 0 00 P F cm Auto off Step 3 Press button to change wavelength Step 4 Press the Enter Button to edit the threshold and then press Up and Down button to increase decrease each character value Press the Mode button to edit the value s positive or negative After setting the first character press Enter button to begin to the next character setting Press and hold Enter button a few seconds to save the settings an asterisk appears Threshold value is made of 4 bits 2 bits integer and 2 bits decimal Each character is from O to 9 in dBm 24 Auto off Current wavelength The threshold value which user has defined Asterisk Saving the settings once pressing Enter button a few seconds 4 Pass or Fail LIMIT mode 25 4 Identifying the wavelength automatically Cooperates with comp
13. tery Status How to measure in db power value Step 1 First set power reference value REF Press and hold dBm W button for a few seconds to set the current power values as power reference value 11 Step 2 Formula and Example are as follow Formula The current value in dBm REF the current value in dB Example REF 46 97dBm the current value in dB 13 79 Then the current value in dBm 46 97dBm 13 79dB 60 76dBm Switch power measure of three types to power value Press dBm W button to switch power measure dB dBm or Watt Change wavelength Press button to change wavelength at 850nm 1300nm 1310nm 1490nm 1550nm and 1625nm Reference value setting Press dBm W button for a few seconds to set the current power values as power reference value in dBm measure 12 Saving data in TEST MODE Step 1 Press Enter button for a few seconds to save the current test result Step 2 User can press Up and Down button for setting the fiber ID Otherwise the unit prepares the fiber ID according to 1 step increment The fiber ID is from 1 to 999 3 2 RECORD MODE In the mode the unit tests and restores fiber power value automatically Users can set the test time the unit works automatically Default is 15 minutes and the sample frequency Default is 5 seconds RECORD MODE Selection Press Mode button to select the RECO mode and then press E
14. x 64 5mm Weight Around 550g without battery 08 Instructions for operation 1 Turn on off the unit Turn the unit on Press and hold the On Off button for a few seconds the unit will display all the screen contents on the LCD until button is released The unit then enters the TEST MODE automatically 1900 Auto a BB BB CW 270Hz 1KHz 2K Hz M NA NA NA NA AN AN UN EN UN nW uW mW dBm mile Km TRBSZL J m Auto off When power is on press On Off button to activate deactivate auto power off function Note auto off time is 5 minutes When power is on press On Off button for a few seconds to turn off the unit 09 2 Backlight function When power is on press Mode button for a few seconds to activate deactivate LCD backlight 3 Mode selection When Power is on press Mode button to enter the mode selection menu 6 Selection Modes TEST MODE RECORD MODE BROWSE MODE SET MODE ZERO MODE and LIMIT MODE Press the Mode button to switch between mode options and press the Enter to select the corresponding mode 3 1 TEST MODE TEST Mode is set by default when powering the unit on In TEST MODE the meter receives fiber power source tests and displays power value and a pass fail indicator by user defined threshold 10 BR ND Note During the power value dBm rate measuring Current Wavelength Power Value TEST mode Bat