1. FOGTIME sec a F 12 e 0 XXX ADDRESS PXX PUMP FXX FAN P PAUSE min F FOGTIME sec TIMER LIT 0 CET XXX ADDRESS PXX PUMP FXX FAN 14 Control panel Timer Menu the red Timer LED 21 shines Adjusting of the output pump in steps of 1 1 99 Adjusting of the wait time in minutes 0 1 99 Adjusting of the fog time in seconds 1 99 Escape to switch back to the Standard Menue with the Enter button 5 Operating the Viper 2 6 5 5 Operating the internal timer With the internal timer the fog time and wait time as well as the output can be adjusted The output of the fan has to be adjusted in the Standard Menue and can t be changed in the Timer Menue To start the Timer Mode press and hold the Mode button 16 for more than 2 seconds The red Timer LED 21 shines as soon as the machine has switched to the Timer Mode As long as the timer is in operation the red Timer LED blinks The adjusting of the output fog time or wait time is the same as in the Stan dard Menu That means you have to press the Mode button until you reach the required function With the Up Down buttons you can adjust the output Pxx fog time F xx and wait time P xx then press the Enter button to start the timer The timer cycle starts with the time last shown on the display P xx Starts with wait time F xx Starts with fog time You can switch back to the Stand
2. back of the machine As soon as the machine receives a correct DMX signal the yellow DMX LED 19 shines Now the pump and the fan can be adjusted via the desk Please note If a fan is connected to the machine the Viper 2 6 uses two channels at your desk Channel 1 Pump Channel 2 Fan 5 4 2 1 Adjusting the DMX start address a Press the Mode button 16 at the control panel until three figures will appear on the LED display 20 b Adjust the requested start address by pressing the Up Down buttons 17 c Save the start address by pressing the Enter button 18 once The start address will also be saved when you disconnect the machine from the mains supply 5 4 3 0 10 Volt DC control Connect the Viper 2 6 to an analog desk or to the cable remote available as an optional extra using the 3pin XLR socket 10 at the back of the machine Please note With analog control the pump can be adjusted from the desk and or the cable remote The fan has to be adjusted directly at the machine a Connect the cable from the desk or the cable remote into the 3pin XLR socket at the back of the machine 10 b The knob on the cable remote or the fader on the analog desk will control the level of the pump c Pressing the On Off switch at the cable remote starts the fog process To adjust the fan output a press the Mode button 16 until a F and two figures appear on the display 20 b Adjust the fan output with the Up
3. aim at persons directly and keep a minimum distance of 3 m to the nozzle e Never touch the nozzle when in operation Danger of getting burnt e The location for the machine must be non flammable non combustible and not sensitive to heat It has to be twice as big as the machine e Keep a minimum distance of 60 cm to all flammable combustible objects and objects sensitive to heat e Glycol is alcohol and burns with a slightly bluish almost invisible flame Never point the fog at strong sources of ignition like fire or pyrotechnic effects e Never open the machine and leave the machine unattended when connected to a power supply e The visibility has to be more than 2 m in rooms where people walk around e Do not swallow the fog fluid Keep it away from children In case of eye contact rinse with a lot of water Consult a doctor should you have accidentally swallowed some fluid e Spilled fluid or splashed fluid droplets can cause slip hazard Mop up the fluid and dispose of it according to regulations e Fog may activate smoke detectors Artificially made fog can be produced in many different ways The method used here to produce fog with a device which works according to the vaporizer principle is the most harmless one No case has so far been reported in which a sound human being has been harmed because of using our device to produce artificial fog However this can only be guaranteed if the professional fog generators are used acc
4. Down buttons 17 12 5 Operating the Viper 2 6 5 4 4 Stand alone The Viper 2 6 can be used in the Stand alone mode In this mode the control of the pump and the fan must be adjusted at the machine a Press and release the Mode button 16 until a P and two figures appear on the display 20 b Adjust the pump output with the Up Down buttons 17 and press the Enter button 18 once to start the fogging process The machine now produces fog until the Enter button is pressed again The output can be changed during the fogging process To adjust the fan output a press the Mode button 16 again until a F and two figures appear on the display 20 b Adjust the fan output with the Up Down buttons 17 5 4 5 Control via Radio remote A radio remote is available as an option It will be delivered with a 3pin XLR plug Connect the receiver of the radio remote to the machine using the 3pin XLR socket 10 on the back of the machine Adjust the requested pump output at the machine see point 5 4 4 Press and hold the first button at the transmitter of the radio remote as long as you want fog to be produced see manual Radio remote 13 5 Operating the Viper 2 6 FZ P PAUSE min F FOGTIME sec TIMER LIT 0 Le XXX ADDRESS PXX PUMP FXX FAN XX P P 3 PAUSE min F FOGTIME sec TIMER READY Le XXX ADDRESS PXX PUMP FXX FAN P PAUSE min F
5. Operating manual Viper 2 6 Viper deLuxe a Look Solutions product Set of Equipment supplied 1 Viper 2 6 or Viper deLuxe 1 tant lid with Quick Connector 1 manual Please check whether all the products you ordered are supplied Contents Introduction Safety instructions Description of the parts Fluid 4 1 General Notes 4 2 Changing the fluid container Operating the Viper 2 6 5 1 Selecting the location 5 2 Putting into operation 5 3 Switching the device off 5 4 Control choices 5 4 1 Using a fan 5 4 2 Control via DMX 512 5 4 2 1 Adjusting the DMX start address 5 4 3 Control via 0 10 Volt DC 5 4 4 Stand alone mode 4 4 5 Control via Radio remote 5 5 Operating with internal timer 5 5 1 Auto start 5 6 Wiring of the sockets Cleaning Care and Maintenance Troubleshooting Specifications Warranty Conditions 16 17 18 19 1 Introduction The Viper 2 6 is a very powerful fog generator It unites the current digital technology with proven technique and power New features guarantee a much more simple operation place and fog reducing the amount of time needed to set up the machine An external fan with one phase and max 800 watts scan be connected to the machine 2 Safety instructions A fog machine is not a toy e Very hot steam escapes from the nozzle Danger of getting burnt e Occasionally very hot droplets of fluid may escape when in operation Thus never
6. X ADDRESS PXX PUMP FXX FA ADDRESS PXX PUMP FXX FAN MN Abb 4 Display shovvn at svvitching off the device 5 4 control choices Please note The Mode button can t be used for scrolling through the Menu The Mode button has to be pressed momentarily If the Mode button is pressed more than two seconds the machine will change into the Timer Mode see point 5 5 5 4 1 Using a fan A fan with one phase and max 800 Watt can be connected to the machine Therefore you need a special plug Hirschmann Stas 3 which you can get from your local dealer If you want to connect a fan with more than one phase you need a capacitor that can be build in the machine afterwards Please ask your local dealer for details and specifications Connect the plug of the fan to the socket 5 at the back of the machine The fan can now be controlled as described see point 5 4 2 to 5 4 4 The fan is already connected to the Viper deLuxe and can be controlled as described on the following pages The fan can be controlled separately and can be used as a wind machine 11 5 Operating the Viper 2 6 You may control the Viper 2 6 externally through the XLR sockets 8 and 10 Please note DMX takes priority That means when the machine is controlled via DMX 512 this data takes priority over 0 10 V DC and Stand alone operation 5 4 2 Operating via DMX 512 Connecting the Viper 2 6 to a DMX desk using the 5pin XLR socket 8 on the
7. ard Menu by pressing the Mode button 16 for more than 2 seconds or by switching to ESC Escape in the Timer Mode and then press the Enter button 5 5 1 Auto start If the timer is in operation and you disconnect the machine from the mains cable the Viper 2 6 will re start in the Timer Mode as soon as it s reconnected to the mains To stop this press and hold the Mode button 14 for more than 2 seconds or switch to ESC in the Timer Mode and then press the Enter button 5 6 Wiring of the sockets 5pin XLR DMX Pin 1 Ground Pin 2 DMX Pin 3 DMX 3pin XLR analog Pin 1 Ground Pin 2 0 10 V DC in Pin 3 12 V DC out max 50 mA 15 6 Cleaning Care and Maintenance Ensure the air vents 7 are not clogged by dust If necessary remove the dust Take care that the machine can not get overheated Do not run the Viper 2 6 without any fluid as the pump will run dry Wipe up spiled Fluid immediately Moisture also fluid can destroy the electric of the machine Check the state of the air valve filter from time to time and clean or replace it when necessary When frequently using the same fluid can it should be cleaned thoroughly before adding new fluid This reduces the chances of the machine clogging up If you install the Viper 2 6 make 100 shure that a permanent fog free air supply for the unit is guaranteed Cooling air with too high fog concentration very often in Clubs and Discos ca
8. by undue force Certain parts of the machine are consumable parts and are not covered by the warranty Guarantee services do not cause an extension of the guarantee time or the start of a new guarantee time The warranty for replaced parts ends with the guarantee time of the whole unit If a defect fault can not be repaired by us in a satisfactory time we will within 6 months after sale of the unit on choice of the customer either e replace the whole unit for free or e refund the lesser value or e take back the whole unit and refund the purchase price but not more than the usual market price at the time of the refund Further claims especially for damages losses etc outside the unit are excluded Other guarantee regulations may be valid outside Germany Please check with your dealer If you should send the unit for service do not forget to remove any liquid from the fluid bottle 19 a Look Solutions product
9. eached the LED illumates permanently Adjust the required output via the control panel and press the Enter button 18 once to start the fogging process see point 5 4 5 3 Switching the device off a Press the Mode button 16 til OFF appears on the display After 15 seconds the machine will switch off automatically On the right bottom edge of the display a red decimal point appear You can also switch off the machine within these 15 seconds by pressing the Enter button 18 When you switch off the DMX signal the machine will be switched off automatically after 15 seconds 5 Operating the Viper 2 6 Control panel Standard Menu 22 Ready LED green 21 Timer LED red TIMER 4 0 pMxXm 20 LED display XXX ADDRESS PXX PUMP FXX FAN 19 DMX LED yellow 6 68 D eo 18 Enter button 17 Up Down buttons 16 Mode button Ir P PAUSE min F FOGTIME sec Abb 1 Display shovvn at adjusting the pump output P PAUSE min F FOGTIME sec tumer READY gt DMX n XXX ADDRESS PXX PUMP FXX FAN E E E Abb 2 Display shown at adjusting the DMX start address P PAUSE min F FOGTIME sec umer O TUE Q CLP XXX ADDRESS PXX PUMP FXX FAN CE E E Abb 3 Display shown at adjusting the fan output 10 5 Operating the Viper 2 6 re PAUSE min ES SOS UMEGe I LRO READY sl DMX n XX
10. i Free of charge subject to the follovving conditions No 2 6 vve vvill repair any defect or fault in the unit if it is caused by a proven factory fault and has been advised immediately after appearance and vvithin 24 month of delivery to the end user Insignificant deviations Of the regular production quality does not guarantee replacement rights nor do faults or defects caused by vvater vvrong fog fluid by generally abnormal environment conditions or Force Majeure Guarantee Service vvill be done in the follovving vvay Faulty parts vvill be repaired or replaced our choice vvith correct parts Faulty units have to be brought to us or our service centres or to be sent to us or our service centres at customer s expense The invoice and or receipt shovving the purchase date and the serial number has to come with the faulty unit otherwise this will not be guarantee service Replaced parts become our property The customer loses all rights for guarantee services if any repairs or adjustments are done to the units by unauthorized persons and or if spare parts are used which are not approved by us The right of guarantee service is also lost if fluids other than original Look fog fluids have been used or if units are sent to us with full fluid bottles Also non compliance with the instructions in this manual or mistakes by incorrect handling treating of the machine will lead to a loss of guarantee and also any faults and damages caused
11. n condense inside the machine and cause moisture damage For cleaning the surface of the device use a suitable solvent free cleaner PLEASE NOTE The vaporizer of our machines does not have to be cleaned Cleaners available on the market can damage the vaporizer We cannot grant warranty in this case 16 7 Troubleshooting The fog machine does not fog Check external control signals Check mains supply Check fluid tank empty Check for correct connections at the fluid bottle Check for fluid in the fluid tube Check if fluid filter is clogged Check that pump setting on the machine is gt 1 The fog machine fogs uncontrollably e Check mains supply e Check unit for moisture moisture inside the machine especially on the PCB can cause fogging The fog machine switches off suddenly e The Temperature cutout has switched off due to overheating Remove external heat source for instance projector shining right onto the housing and or make sure sufficient fresh air supply After 15 to 30 minutes the unit should switch back to on again Loud droning sound during fogging e The pump is running dry Avoid this absolutely e Refill or better replace fluid bottle e Double check connection fluid tube and fluid bottle E 4 appears on the LED display e The machine is getting too hot The heating switches off and the machine cools down Solution Disconnect the machine from the main supply for a moment and then re co
12. nnect it E 1 E 2 E 3 appears on the LED display e Please send the machine to the service station or your local dealer 17 8 Specifications Fog generator Procedure Power requirement Voltage Warm up time Fluid consumption Fluid tank capacity Fog output Output projection Fogging time external Fan Air quantity Control Temperature control Overheating protection Dimensions L x W x H Weight without tank Look Fan Procedure Power requirement Voltage Air volume Current Capacitor internal Dimensions LxWxH Weight incl Case Viper deLuxe Dimensions incl Case LxWxH Weight incl Case Manufactured for vaporizing fog generator 2600 Watt 230 V 50 Hz approx 7 min at max output at cont output 5 Liter adjustable in 99 steps steps 1 max 15 m at 100 output approx 40 sec at lt 50 output continuous output max 800 Watt fan with one phase adjustable in 99 steps DMX 512 0 10 V analog Timer Stand alone mode Radio remote Option Microprocessor controlled Heater block Thermostat Pump Thermal switch 52x23x25cm 12 kg 240 ml min 70 ml min Centrifugal blower 355 Watt 230 V 50 Hz 1060 m3 h 1 55 A 8 u 450 VDB 22 x 19 9 x 21 6 cm 3 6 kg 75x42x77cm approx 47 kg Look Solutions Fog machines made in Germany 18 9 Warranty Conditions For the fog machine Viper 2 6 Viper deLuxe Look guarantee is 1 T
13. ordingly i e at the correct vaporization temperatures as well as with the correctly mixed fog fluid We however recommend People with health problems or problems of the respiratory tract or with an inclination for allergies should avoid any contact with artificially made fog 3 Description of the parts Front view AN 1 Nozzle Rear view c 2 3 4 5 6 2 Fluid tube 3 Fluid tube inlet 5 Socket for external fan 4 Fuse for external fan 6 Mains cable 3 Description of the parts Top view Tank lid N Ll B Air vents DMX in out Control panel for adjusting the DMX start address and the output XLR socket f 0 10 V DC Brass coupling Brass collar Tank lid Check valve Fluid filter 4 Fluid 4 1 General Notes The Viper 2 6 has been designed to be used with Look fog fluids The following Look fog fluids are available Quick Fog thick quick disappearing fog fluid Regular Fog thick long lasting fog fluid Slow Fog thick extremely long lasting fog fluid If fluids have been used other than Look fog fluids we can t grant warranty on parts that have been in contact with the fluid PLEASE NOTE The vaporizer of our machines does not have to be cleaned Cleaners available on the market can damage the vaporizer We cannot grant warranty in thi
14. s case 4 2 Changing the fluid can Disconnect the fluid tube from the lid by retracting the brass collar 12 and removing the coupling 11 Remove the can from the tank housing of the Viper 2 6 Unscrew the lid 13 of the empty can and screw it onto the new container Place the full can into the tank housing Push the brass coupling 11 into the brass collar 12 until you hear a click The brass collar is now locked firmly 5 Operating the Viper 2 6 5 1 Selecting the location The location in which the Viper 2 6 is to be operated must be dry be free from dusty or polluted air be free from vibrations be an non flammable place or surface be well ventilated with fog free air keeping the ambient operating temperature between 5 C and 45 C and the relative air humidity below 80 8 5 Operating the Viper 2 6 The Viper 2 6 is a powerful fog generator producing every desired effect from a tiny puff of smoke to the thickest fog Digital technology makes fine adjustments of the pump possible In steps of 1 the output can be adjusted from 1 99 5 2 Putting into operation a Connect the Viper 2 6 to the mains supply Make sure the correct voltage is selected 230 V 50 Hz A P and two figures appear on the display After a warm up time of approx seven minutes the Viper 2 6 is ready to start The green Ready Led 22 blinks if the working temperature is reached As soon as the final temperature is r