Home

How to configure NetComm IAC4500 for billing by volume

image

Contents

1. Broadband Soltions How to configure the IAC4500 Internet Access Controller for Billing by Volume Application with NCT480 IP DSLAM using port location mapping Introduction The following paper provides instructions on how to configure NetComm s IAC4500 Internet Access Controller with NetComm NCT480 IP DSLAM for billing by volume application It specifically focuses on the IAC4500 s new feature billing by volume under deployment scenarios A Port Location Mapping for 802 1Q VLAN Tagging This document is being created at a time when the following versions of firmware were in production e AC4500 Firmware V1 02 05 e NCT480 Firmware R2 32 Note IAC4500 with firmware V1 02 05 or later supports billing by volume The test PCs that used in this white paper were running WinXP with Internet browser IE7 0 The web interface of the devices under test in this white paper are best viewed with Microsoft Internet Explorer 6 0 and above at 800 x 600 resolution It is recommended that the readers of this document has read and understood the IAC4500 amp NCT480 user manual How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page IAC4500 VLAN Management The IAC4500 offers two methods of connection User can either be issued a unique user name and password which is required on log in or using VLAN tagging the Port Location Mapping Feature in the IA
2. CL Page 21 Login Microsoft Internet Explorer provided by NetComm MEIR JS v http 1 1 1 1 http wa google com au service cgi bea X Google fef Fie Edit view Favorites Tools Help Links gt we a Poon fey Home BJ Feeds 3 dh Print gt Page Tools Please choose from the following service selection 25MB 2 00 vi 1 day 10 00 10 minutes 1 00 Please kindly note that there will be no refund once connectivi PANS AZANI Flease note that the time block of selected service is based on continuous usage Please click ENTER to confirm your acceptance of the usage charge or CANCEL to exit The selected service charge will be posted directly into your guest folio Cancel NetComm Limited NetComm NetAssure NetAssure Demo Site NetAssure Live Site Copyright c 2004 2015 All Rights Reserved Login Microsoft Internet Explorer provided by NetComm Gr http f1 1 1 1 http www google com au service cgi b 4 x Google ej Fie Edit View Favorites Tools Help Links gt w k tog fy Home Feeds J mh Print gt Page Of Tools Welcome Please choose from the following service selection 25MB 2 00 v Please kindly note that there will be no refund once connectivity is confirmed Please note that the time block of selected service is based on continuous usage Please click ENTER to confirm your acceptance
3. Feeds J dah Print gt Page Tools Internet Subscriber Server III PLUG AND PLAY SECURE ACCESS CONTROLLER Configuration Menu Current User List a Configuration Menu 4G System Setting Eg Advanced Setting i 2008 10 28 2008 11 02 a System Status 102 3 Profile 3 18 09 42 18 09 42 i System Current User List A DHCP Clients GO 1 Page M First 4 Previous Next gt End Mi Session List i 0 NAT Pool Table IP Address MAC Address Disconnect 10 59 1 10 00 0D 60 77 BC FB O D LAN Devices D PMS Transaction D Static Routing Table H System Tools IAC4500 Powered by Handlink Technolog Internet Subscriber Server Ill How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 24 User Configuration Interface Microsoft Internet Explorer provided by NetComm GI v e http 10 59 1 1fenter cai v 9 x File Edit View Favorites Tools Help w k e User Configuration Interface Mettammr NEtComm Com 84 Configuration Menu amp Configuration Menu Eg System Setting Eg Advanced Setting Es System Status Current User List DHCP Clients Session List NAT Pool Table LAN Devices PMS Transaction _ Static Routing Table 9 System Tools IAC 4500 No 1 102 GO 1 Page Links gt Home Fy Fe
4. Y to Port 48 ii m O J gt Increment False llemux fin Support E Done Internet Address http 192 168 1 1 login html v Je Links E Menu Af System ae Status amp performance ay Deployment Ri 3 ca tri gt o E DSL profile configuration LLI co ca co ca SNMP host E SNMP community E Alama VO control HO Access control Ho Protocol HE Diagnostic ney Other co co co ca IK TEE i EE LIL TNT Step 2 Navigate to POTS 24 All port is selected EOA EOA tri O o gt vlan ID priority wlantag other Mux llctnux MAC limit 16 Mux Ilcmux MAC limit 16 Mux Icmux MAC limit 16 Mux Icmux MAC limit 16 Mux llctnux MAC limit 16 Mux Icmux MAC limit 16 Mux Icmux MAC limit 16 Mux Ilcmux MAC limit 16 Mux Icmux MAC limit 16 o o o I Lill How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 6 Menu gt Protocol gt VLAN port gt Ensure that the default VLAN ID is 1 This means that all the downstream traffic from IAC4500 untagged traffics will be accepted and they will go via default VLAN group 1 in the Eth 1 to all the 48 ADSL ports of the NCT480 Address http 192 168 1 1 login html vi
5. By integrating with a hotels PMS the system can post charges for Internet access directly to a quests hotel bill Charge Mode only for Port Based on Room Location Mapping enabled Based on Subscriber Regenerate password of static ve account with PMS checkout only for Scenario B Micros Fidelio Spectrum MK Il Revenue Code O Marriott Revenue Code Reference Internet Proprietary If the site does not have a listed PMS Micros Fidelio Spectrum MK II or Marriott then select Proprietary and use Net Retriever software a middleware between IAC4500 and other PMS systems to allow the IAC4500 to communicate and pass on the billing data to the PMS system Then click Apply to apply settings 8 Save Configuration and Reboot System 9 Back up configuration file amp Port Location Mapping Table as they are two separate back up files Aside This white paper does not include any IAC4500 management IP access list and IP MAC URL filtering as these settings varies from site to site It is generally recommended that the appropriate settings are configured in the device to ensure some level of secure access control and that the necessary system log files are sent to system manager for system management How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 20 Connect Test Modems amp Test Internet Access 1 Set the test
6. FJ co links POTS Line 48 25 T 3 Menu Ethernet port 1 HL System Ethernet port 1 is selected HE Status amp performance Accept frames type Ag Deployment H Access control 1g Protocol E WLAN port o E Trunk VLAN setting E IGMP snooping E DHCP PPPOE relay Rapid spanning tree protocol HE Diagnostic EC Other Step 3 Navigate to Menu gt Protocol gt Trunk VLAN Setting gt ADD This means Eth 1 will assign the data packets from VLAN group 101 148 with their corresponding VLAN tag number when it leave the port to the IAC4500 How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 7 r Address http 192 168 1 1 login html v E co iink gt I Menu VLAN mode setting I System 3 Deployment HE Access control F _ ntagge EN Protocol E i None E ZLAN port Untagged Trunk VLAN setting E IGMP snooping http 192 168 1 1 Add trunk VLAN Micr E C DHCP PPPOE rela 2 Spanning tree protocol tree protocol Ethernet port 1 1 Rapid spanning tree protocol on 101 M Increment HI Diagnostic CJ Other 48 Internet Address E http 192 168 1 1 login html vi Go Links gt A J Menu VLAN mode setting 3 HE System HC Status amp performance Apply ic Din
7. of the usage charge or CANCEL to exit The selected service charge will be posted directly into your guest folio Windows Internet Explorer Y You have selected 25MB 2 00 You will be charged immediately after this confirmation NetComm Limited NetComm NetAssure NetAssure Demo Site NetAssure Live Site Copyright c 2004 2015 All Rights Reserved gh Internet 100 How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 22 This information will be sent to the PMS system via the PMS console port at the face panel of the IAC4500 Note if the following page is presented instead of the login page above then the setup for scenario A Port Location Mapping Billing is incorrect Please review the above steps regarding port location mapping on devices mentioned above Welcome Cm 0 6 Surf the Internet Test complete 7 NetComm Australia Broadband Solutions Products And Services Microsoft Internet Explorer provided by NetComm Go v e http iwww netcomm com au vi 4 X Google Edit View Favorites Tools Help w dr netComm Australia Broadband Solutions Products A fap Home EJ Feeds 3 d Print gt Page Tools Metan en ANT r 1C DIUduvallu cut Solutions Products Services Support About NetGomm Resellers Only Investors Contact Us Lea
8. 21 121 Charge for use F 122 122 Charge for use O 123 123 Charge for use F 124 124 Charge for use F z IAC4500 Powered by Handlink Technology internet OE Server Ill 6 Activate Bandwidth management according to Billing Profile settings navigate to Configuration Menu gt Advance Setting gt Bandwidth Management gt Select Bandwidth Management and Select Class of Service based on RADIUS or billing profile settings then click Apply Aside If you are planning to have equal bandwidth for all subscribers regardless which billing profiles they are under you may select the first option on the Bandwidth management page How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 18 User Configuration Interface Microsoft Internet Explorer provided by NetComm GJ e http 10 59 1 1 enter cgi vi 43 36 coogie Ee File Edit View Favorites Tools Help Links gt gt So ________ gt w user Configuration Interface fap Home EJ feeds 1 dah Print i Page Of Tools Internet Subscriber Server III PLUG AND PLAY SECURE ACCESS CONTROLLER A Configuration Menu Bandwidth Management a Configuration Menu Bandwidth Management Hag System Setting Equal bandwidth for all subscribers HE Advanced Setting as D Credit Card The function enables administrator to limit bandwidth usage on a p
9. C Rooms can then be recognized via its room number Both options in the IAC4500 offer zero configurations for subscribers hotel room guests Guests simply plug the Ethernet cable into their laptop enter a username and password or simply accepts the terms and conditions and they are connected without changing any settings at all VLAN Management A VLAN allows a physical network to be divided into several logical networks A device can belong to more than one VLAN group Devices that are not in the same VLAN groups can not talk to each other VLAN can provide isolation and security to users and increase performance by limiting broadcast domain VLAN tag can be added to the MAC header to identify the VLAN membership of a frame across bridges A tagged frame is four bytes longer than an untagged frame Each port of NCT480 is capable of passing tagged or untagged frames Each port has its own Ingress rule If Ingress rule accept tagged frames only the switch port will drop all incoming non tagged frames If Ingress rule accept all frame type the switch port simultaneously allow the incoming tagged and untagged frames An untagged frame doesn t carry any VID to which it belongs When an untagged frame is received Ingress Process insert a tag contained the PVID into the untagged frame Each physical port has a default VID called PVID Port VID PVID is assigned to untagged frames or priority tagged frames frames with null 0 VID received on this po
10. PLAY SECURE ACCESS CONTROLLER Port Location Mapping List 5 Configuration Menu amp Configuration Menu Cr Bey System Setting D System D WAN I LAN d D NAT Pool Basil D Authentication 106 Room 106 Chageforuse O 7 ao HE are 1 Room Ghargeforuse D Eg System Status 110 IR Se System Tools r mte Ghargeforue O E a Char o vi 1AC4500 Internet Subscriber Server Ill How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 17 Address http 10 59 1 t enter cai v Go Links gt HEILT Internet Subscriber Server III WWWSCLCOIINT CON EU PLUG AND PLAY SECURE ACCESS CONTROLLER A A Configuration Menu 109 109 Charge for use O a Configuration Menu 110 110 Charge for use F ag System Setting 111 111 Charge for use O 1 System 112 112 Charge for use F WAN LAN D Sewer 113 113 Charge for use O i NAT Pool 114 114 Charge for use F Authentication 115 115 Charge for use F pE Billing 116 116 Charge for use gog Accounting 117 117 Charge for use F I 3 Port Location t Mapping 118 118 Charge for use O He Advanced Setting J 119 119 Charge for use F HS System Status Ef Svstern Tools 120 120 Charge for use F 1
11. ackets being sent to the IAC4500 and accept untagged packets being sent from the IAC4500 to the device Figure 1 illustrates the logical network diagram for NCT480 IP DSLAM working with an IAC4500 Logical Network Diagram MELDT Room 101 Port1 7 DSLAM Cable vet Port 25 48 FR Connect to MDF DSLAM Cable Port 1 24 Connect to MDF DSLAM Cable Port 1 24 Subscribers Hotel Room Users DSLAM Cable Port 25 48 Subscribers Hotel Room Users 7 Figure 1 NCT480 with IAC4500 Internet Access Controller How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 3 NCT480 VLAN Management There are 3 types of management interfaces available for NCT480 IP DSLAM system management The web management interface the CLI interface and the Telnet interface It is recommended to use the inbuilt web management interface for NCT480 system configuration This white paper is written in the basis of using the web management interface of the NCT480 IP DSLAM The characteristic nature of IAC4500 s 802 1Q VLAN tagging feature is that the IAC will accept VLAN tagged packets from its LAN network and only respond to its LAN network with untagged packets Due to this VLAN tagging behaviour of the IAC4500 NCT480 will be configured to the following way in this test scenario 1 All traffics from the 48 ADSL ports data upstream direc
12. als places 7 D WAN LAN Traffic Base Idle Time out 5 minutes 5 60 Traffic Base Account i Sener Expire 5 days 1 365 1 NAT Pool No Active Name Description Profile Setting Authentication 01 Profile 1 1 day 10 00 z Billing a 02 Profile 2 10 minutes 1 00 Accounting 7 9 PorLocation 03 Profile 3 25MB 2 00 Edit Mapping i Edit EE HE Advanced Setting ai L D Credit Card O D Customization 06 go D Bandwidth 07 o za Portal Page 7 0 Advertisement i a I Walled Cardan Mi 09 O lt u amp en a EE IAC4500 T gt v internet Subscriber Server Ill How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 14 http 10 59 1 1Aveb136 cei Microsoft Internet Explorer provided by NetComm Sisk E http 110 59 1 L web138 cai File Edit View Favorites Tools Help ve ode ihttp 10 99 1 4 meb138 c0 he 0 tome Billing Profile Setting No 1 Description ldar 1000 Note Do not support multi users using one account at the same time Note You must activate the bandwidth management feature and select a dass of service imit Maximum Upstream Bandwidth im 126 Kbps sho Od Maximum Downstream Bandwidth a 512 Kbps wh 0 How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 15
13. e Tagger age A None AG A trol ccess contro Untagged fl T en Protocol VLAN port Tagged W O Trunk VLAN setting 102 Tagged v o E IOMP snooping 103 Tagged d Spanning tree protocol O l i 3 Rapid spanning tree protocol 105 Tagged vw d H Diagnostic 106 Tagged d Z SE Other 107 Tagged vw d 108 Tagged d 109 Tagged d 110 Tagged vw oO aall Tagged vw O 112 Tagged d ape a How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 8 Tagged Vi F a L System Ge Status amp performance Ethernet port 1 134 Tagged O ae Deployment Ethernet port 1 185 Tagged d EG Access control Ethernet port 1 136 Tagged go EE Protocol Trunk VLAN setting Ethemet port 1 138 Tagged ML E IGMP snooping Ethernet port 1 139 Tagged O PE DHCP PPPOE relay Ethernet port 1_ 140 Tagged v o Spanning tree protocol Ethernet port 1 141 v 0 Rapid spanning tree protocol agged O EE Disgrosti Ethemetpor 1 142 Tagged v O HS Other Ethernet port 1 143 Tagged vw D Ethernet port 1 Tagged v OD v Step 4 Navigate to Menu gt Commit amp Reboot gt Commit then Reboot system Address http 192 168 1 1 login html v Je Links gt ae Conn ag System Restore factory cofgwaton Rena Statistics C User amp password Bridge mode E Backup a
14. eds 3 dghPrint ib Page Oj Tools Profile 3 Internet Subscriber Server III PLUB AND PLAY SECURE ACCESS CONTROLLER Billing Log Export to Txt Billing Profile Usage Time Volume Bin Charg 2008 10 28 18 09 42 25 MBytes 2 00 Private Ph M First 4 Previous N gt internet Subscriber Server Ill How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 25
15. er user basis MAC address a wa That prevents users from consuming a disproportionately large amount of bandwidth so every user Customization gets a fair share of the available bandwidth 0 Bandwidth D Portal Page Maximum Upstream Bandwidth 256Kbps O o Kbps 64 24576 i D Advertisement E Maximum Downstream Bandwidth 256Kbps v O 0 Kbps 64 24576 Walled Garden L _ Passthrough Class of service based on RADIUS or billing profile settings F E Filterin The function enables administrator to limit bandwidth usage according to the RADIUS vendor specific i sn attribute RADIUS authentication or billing profile setting Built in authentication This allows every j LAN Devices user to have a different service quality for Internet bandwidth D Static Route ED eed ia Logs D Session Trace 2 SNMP J lt ji amp IAC4500 Powered by Handlink Technolog Internet Subscriber Server Ill 7 Select the Property Management System PMS Click on PMS Configuration under System Settings gt Billing and select the PMS and click Apply How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 19 Billing Profile PMS Configuration Many hotels use PMS as a hotel in door billing system for their quests including room service mini bar telephone usage as well as Internet service
16. gt http 110 59 1 Tiweb140 cgi Microsoft Internet Explorer provided by NetComm Aa T E http 10 59 1 1web1 40 cgi File Edit View Favorites Tools Help w be Shep f10 93 1 1 meb1 40 0 A gt Home Ho 3 Description AMB 40 Pe Duration Charge Check Time Selective Unit F romil is 0 Period Time finish dg minute Toi romi l From UG im Period Time finish i Time base Expire when O0 01 M Period Time finish im Traffic base Note Do not support multi users using one account at the same time a Note You must activate the bandwith management feature and select a class of service Maximum Upstream Bandwidth i 128Kbps Sho Maximum Downstream Bandwidth my 512Kbps LO Do Please note that traffic based billing counts both the download and upload data volume 5 Create a port location mapping table with all the VLAN ID that were set in the NCT480 IP DSLAM Please navigate to gt system setting gt port location mapping How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 16 Single Create Status No Charge Charge for use Blocked Address http 10 59 1 1 fenter cgi v MRI Internet Subscriber Server III KWWW NEtCOnNm Com 8lu PLUG AND
17. ing No Option Yes Time to Finish Based on Room Based on Subscriber Need to continue configuring Billing and choose at least one active billing profile Need to continue configuring Port Location Mapping Table O Scenario B General Yes Time to Finish Need to continue configuring Billing and choose at least one active billing profile billing profiles that used in this test scenario Scenario C No General Yes Option No Time to Finish Accumulation idle Timeout M 5 S 1 1440 Accumulation account will be deleted after logged in 7 r 9 C Allow Credit Card Payment Internet v Ago example How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 13 User Configuration Interface Microsoft Internet Explorer provided by NetComm GI v E http 10 59 1 L enter cgqi ver x File Edit View Favorites Tools Help ww e User Configuration Interface Mettammr NCECOIUTCOM EL Goo q le Home By Feeds 3 dghPrint ib Page Tools Internet Subscriber Server III PLUG SND PLAY SECURE ACCESS CONTROLLER Billing Profile PMS Configuration Configuration Menu a Configuration Menu Billing Profile Ely System Setting E system g Currency Number of decim
18. ing i f _ Accounting and Accounting settings to complete your setup E Port Location ka i or Current preset option Scenario A Select option Egy Advanced Setting O RADIUS H a C Check Local Account first izati oe Accumulation a Bandwidth Time to Finish No idle timeout Portal Page o a Server IP address Advertisement Pog Primary RADIUS Authentication Port 0 i Lu Walled Cardan s S lt i g erver Accounting Port 0 v 1AC 4500 Powered by Handlink ecnnoiocg internet Subscriber Server Ill How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 12 gt http 10 59 1 1Aveb8 cgi Microsoft Internet Explorer provided by NetComm P tl Gal Y E http 10 59 1 1 web8 cgi WY Tey File Edit view Favorites Tools Help w http f 10 59 1 1 web8 cgi Links fap Home EJ Fe dh Print Page Of Tools tems check PMS billing system Infrastructure Need username password when guests go to Internet Need to create static accounts Allow guests to select service when first login Billing mode BilingCharge mode Default Billing Profile Remarks Done 4 Create Billing Profiles Please refer to screen shot below for three Express way to fit your business model amp Scenario A Yes C Output bill to AG Number of copies lv Port Location Mapp
19. k ADD to recreate PVC for VLAN ID 101 148 Address http 192 168 1 1 login html v Eco Links gt POTS 24 1 All port is selected SJ Menu og System 3 Status amp performance By Deployment 2 DSL port E DSL profile configuration E DSL profile mapping o E DSL alar profile E Power management mode E PVC setting E IPoA route setting E Ethemet port E Ethemet setting SNMP host CP SNMP community o E Alam IO control Ha Access control ao Protocol Eg Diagnostic HE Other ll ca 2 j Are you want to delete selected PYC s co co MW co Mux Icmux MAC limit 16 Mux llctnux MAC limit 16 Mux Icmux MAC limit 16 Mux Ilcmux MAC limit 16 Mux Ilcmux MAC limit 16 ca ca co ca KK How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 5 Address http 192 168 1 1 login html v Eco uns 3 Menu Af System Ge Status amp performance ay Deployment ET Ethemet setting TF SNMP host E SNMP community E Alam 10 control ne Access control ae Protocol Og Diagnostic HE Other Once Bulk Add completed The port will have a PVID of 101 148 instead of the default VLAN 1 POTS 24 All port 15 selected From Port 1
20. modems at the guest rooms to WAN Bridged Mode LAN DHCP server OFF If the CPE you are using is loaded with NetComm Bridged firmware like NB6Series R2T8 Bridged modem then there is no need to re configure the modem in the room it will be just a plug and play device for this test scenario 2 Connect the test modems to an ADSL Port of the NCT480 DSLAM system The ADSL data point socket in the guest room and wait for ADSL light on the test modem turn solid green 3 Connect test PC to the LAN Port of the test modem Note TCP IP setting of the PC is to be set to obtain IP Address DNS address from DHCP server automatically 4 Wait for a valid IP address assigned by the IAC4500 to your subscriber PC Local Area Connection Status x General Support Connection status el Address Type Assigned by DHCP td IP Address 10 59 12 Subnet Mask 255 0 0 0 Default Gateway 10 59 1 1 Windows did not detect problems with this connection IF you cannot connect click Repair Close 5 Once a valid IP address received by the subscriber guest room PC open Internet browser Attempt to access the Internet by browsing a website If PLM has been setup correctly the following page will be presented You will then select and accepts Internet access condition and hit Enter then OK How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008
21. mp restore E Firmware upgrade E Commit amp reboot no Status amp performance Ho Deployment ae Access control ne Protocol HE Diagnostic HE Other How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 9 Address 4 http 192 168 1 1 login html v Je inks 3 Menu Ey System E Information Statistics A User amp password Microsoft Internet Explorer E Bridge mode 4re you want to reboot right now B Backup amp restore DSLAM commit success Firmware upgrade E Commit amp reboot 3 Status amp performance 23 Deployment CJ Access control EG 3 Protocol HO Diagnostic E Other Microsoft Internet Explorer Eg A DSLAM reboot success How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 10 IAC4500 Internet Access Controller Configuration The following settings are made to the IAC4500 Connect the PC to the LAN port of the IAC4500 IAC4500 Default IP Address 10 59 1 1 8 Default User Name admin Default Password admin 1 Enter all system information to the IAC4500 System System Host Name NetCommlAC4500 Domain Name NetComm Location Name NetComm Ltd Max 50 Address Unit 1 2 6 Orion Rd Max 200 Cit
22. rn all about Information Microsoft Internet Explor 4 x http 1 1 1 1finfo html v Information Window You can use Internet now This is an information window to show the usage and notice a You can type http 1 1 1 1 info to open this window again Register For Warranty without VPN connection 5 mes Businesses And ISP s Click here now to register for Remaining Usage 24 99 Mbytes warranty on any NetComm product 1 winning publicly listed Australian company dedicated to providing home iders ISP s with broadband Internet products and services Drivers Firmware amp Troubleshooting work service designed for small to medium businesses and has also Click here for the latest firmware device drivers and troubleshooting y a L Internet 100 Yi 3 Internet Aio To view current IAC user list please refer to Appendix A enclosed in this document How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 23 Appendix A To view or disconnect current IAC4500 login user please login to the IAC4500 and navigate to Configuration Menu gt System Status gt Current User List User Configuration Interface Microsoft Internet Explorer provided by NetComm Go bttp 10 59 1 1 enter cai v 4 Xx Google File Edit View Favorites Tools Help E w user Configuration Interface fey Home
23. rt Figure 2 illustrates the VLAN Tagging relationship between the NCT480 and the IAC4500 DSL lines IAG4500 s Port Location Mapping Table keeps a record of the VLAN database Port I _ N that were set in the NCT480 Port 2 22 Ethernet 1 Port Port 3 INTERNET Network Port 42 Port 41 Port 43 Port 45 Port 46 Port 47 Port 45 3 4 Ethernet 2 Port Intranet Port I Room 101 Port 48 Room 148 with its individual Tag for IAC 4500 for guest room Figure 2 802 1Q VLAN Tagging relationship between NCT480 and IAC4500 How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 2 The IAC4500 uses Port Location Mapping PLM for Scenario A authentication only Scenarios B and C are not covered in this paper PLM insists that the network into which the IAC4500 is installed supports IEEE 802 1Q VLAN tagging for packets traveling between the IAC4500 and the network As the name suggests PLM assigns a unique VLAN ID VID to each room or location in order to bill the room using a Property Management System PMS e g Micros Fidelio installed at the premises The IAC4500 s PLM feature will accept 802 1Q VLAN tagged packets and send back untagged packets to the device connected to a particular port It is therefore important to confirm with the manufacturer of the 802 1Q VLAN device used on the network that it supports the ability to tag p
24. tion will leave the NCT480 with a VLAN tagged number room number 2 All the traffic coming from the IAC4500 to the NCT480 data downstream direction are with untagged default VLAN number 1 The NCT480 running firmware R2 32 requires configuration make via its web interface to perform the above configuration Please refer to screens shots shown in following section Step 1 Login to NCT480 web management interface Default IP address for Eth 3 system management port 192 168 1 1 24 Default User Name admin Default Password admin To check system firmware version please navigate to Menu gt System gt Information How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page 4 S Men Desonpion 1 NCT4SO FiA System Up time 0 day s 7 hr 32 min 54 sec E Information Tiea Contact Unit1 2 6 Orion Rd Lane Cove NSW 2066 AUSTRAI p Statistics User amp password Name sales netcomm com au Fansen Location Unit 1 2 6 Orion Rd Lane Cove NSW 2066 AUSTRAI packs ret Fr E Commit amp reboot HE Status amp performance J Access control ae Protocol HE Diagnostic HE Other Done Internet NCT480 R2 32 System Default Information Navigate to Menu gt Deployment gt PVC Setting gt Select All Port from the dropdown list and hit Delete to delete the default PVC Then Click on Bul
25. way 172171 1 H System Tools Primary DNS Server 172 17 1 1 Secondary DNS Server 4 2 2 2 E PPPoE Mostly for ADSL modem users v 1AC4500 Powered by Handlink Technology internet Subscriber Server Ill 3 Set IAC4500 to use Built in Authentication Scenario A Bill by room number Please navigate to Configuration Menu gt System Setting gt Authentication gt Built in Authentication gt select option Scenario A then click Apply at the Scenario Guide and Apply at the Authentication Configuration page User Configuration Interface Microsoft Internet Explorer provided by NetComm GJ v http 10 59 1 1 enter cqi a IE Google 2 File Edit View Favorites Tools Help Links gt n w k user Configuration Interface Home Feeds J dh Print gt Page Of Tools Internet Subscriber Server III PLUE AND PLAY od eT AC DODESS CONTROLLER A A Configuration Menu Authentication Configuration a Configuration Menu Authentication Type Si 33 year Hk o Authentication a System E User Agreement i WAN LAN O Redirect URL Link Code L i Standard User Agreement page NAT Pool E Built in Authentication E Authentication E Three pre configured options are provided for easy setup Select an option that i a Billing best suits your network needs You must then proceed to configure the Bill
26. y Lane Cove Max 50 State Province NSW Max 50 Zip Postal Code 2066 Max 10 Location Information Country Australia Max 50 Contact Name Max 50 Contact Telephone 02 9424 2000 Max 50 Contact FAX 02 94242010 Max 50 Contact Email support netcomm com au Max 50 Date 2007 W 4 26 Year Month Day Time 13 B 04 v 30 S Hour Minute Second 2 Configure IAC4500 WAN LAN settings configure the WAN to a mode and with IP addresses that suitable for your network environment Eg you may set the IAC4500 WAN to a static IP of 172 17 1 34 24 with gateway 172 17 1 1 24 How to configure NetComm IAC4500 for billing by volume application with NCT480 IP DSLAM using port location mapping Nov2008 CL Page I I Meteo Internet Subscriber Server III PECURE AND FCAT SECURE AOOESS DONTARAOCCERN A Configuration Menu WANILAN 3 Configuration Menu The Device IP Address and Subnet mask settings Ee System Setting LAN IP Address 10 59 1 1 System Subnet Mask 255 0 0 0 WAN LAN m WAN MAC Add pA ress O Change to 00 00 00 00 00 oo Get automatically from a DHCP server Use fixed IP address You have static IP information from your ISP Port Location IP Address 172 17 1 34 Mapping i Hga Advanced Setting Subnet Mask 255 255 255 0 Hea System Status WAN Port Mode Default IP Gate

Download Pdf Manuals

image

Related Search

Related Contents

Mode d`Emploi  ENH1750EXT User Manual - EnGenius Technologies, Inc.  Kodak KLIC-7004 User's Manual  HDMI連動機能 取扱説明書  PIASTRA PER CAPELLI  Memorex miniMove Mix3    取扱説明書・料理集  User Manual - Smart Witness  D-Link NIC ENet 108Mpbs Wless PCCard 32bit  

Copyright © All rights reserved.
Failed to retrieve file