        System Management Bus (SMBus) Specification , version 3.
         Contents
1.                                 2014 System Management Interface Forum  Inc   All Rights Reserved    78 of 85    System Management Bus  SMBus  Specification Version 3 0                                                             Fast mode Plus   1 MHz Class  Symbol  Parameter PC mode device SMBus device   Units   Comments  Min Max Min Max  Vi related input level  0 5 10 3 Vi         V  Fixed input level         1 35 Vop V  V        ES Von related input level 0 7 Von   Voomax y   0 5  V 0 05 x   0 08 V  HYS V  DD  VoL LOW level output             0 4 V lo     20 mA  vonage   0 4     V  lo    3 mA   Vo  gt 2V    0 2 x       V lou    2 mA   Von Vop  lt 2V  lou LOW level output  20             mA  Vo   0 4 V  current  lLeak 8us   Input leakage per bus      200 200 UA  Segment  Cous Capacitive load per bus     550     400 pF  segment  foma  fsc    Bus operating frequency   1000 10 1000 kHz  trmeour   Detect clock low timeout         25 35 ms  tHiGH Clock high period 0 26     0 26 50 us  ttow sexr   Cumulative clock low             25 ms  extend time  slave  device   tLow mexr   Cumulative clock low             10 ms  extend time  master  device   tor Output voltage fall time 20 x 120         ns   Vpp 5  Note 2  5V   tr Output voltage fall time 20 x 120     120 ns   Voo 5    Note 2 Note 3  5 V    tror Time in which a device             500 ms  must be operational  after power on reset                               Note 1  The maximum input high voltage is the lesser of 5 5 V or Vop
2.               Initialize Used  Address Pool       Ar    2  Send    Prepare to ARP                         SMBus Packet  Received     ARP Complete          Notify  ARP Master     Command     Process non ARP  Related Packet              First Three Bytes  ACK ed And Received Byte  Count Equals 0x11     No          Choose An Address  Not In The  Used Address Pool    Is Device Slave  Address Field  Equal To OxFF                             Is Device Slave Yes  Address Fixed      UDID 127 126    00    10 Is Device Slave Yes    Address Field In The  Used Address Pool        12  Send    Assign Address    Command  With The UDID Received From The     Get UDID    Command                     Add Address  To The  Used Address Pool              Figure 61  ARP master behavior flow diagram       2014 System Management Interface Forum  Inc  63 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    6 6 3 12  ARP capable device behavior    Referring to the flow diagram in Figure 62 an ARP capable device operates as  follows     1     10     11     12     13     14     After exiting the power on reset state  a device that supports the Persistent  Slave Address  PSA  will go to step 2 to see if it is valid  If the device does not  support the PSA  it will proceed to step 5     A device supporting PSA must check its Address Valid flag which is a non   volatile  If that flag is set then it has previously received an assigned slave  address and proceeds to step 4  
3.        2014 System Management Interface Forum  Inc  71 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Appendix A  Optional SMBus signals    Ai  SMBSUS     An optional third signal  SMBSUS   goes low when the system enters the Suspend Mode   Suspend Mode refers to a low power mode where most devices are stalled or powered  down  Upon resume  the SMBSUS  returns high  The system then returns all devices to their  operational state     The SMBSUS  signal is included for clarity and completeness since many of the functions  served by the System Management Bus relate to suspend and resume of the system     The system can use the SMBCLK and SMBDAT lines to program device behavior  During  normal operating mode the system may issue configuration commands to different devices   Those commands may tell the device how it is supposed to behave whenever the SMBSUS   line goes active  For example  the system might tell a power plane switcher to turn off power  to the hard drive but keep the keyboard controller on when the system goes into suspend  mode     tsuswidth     M    Tdat2sus   tsus2olk H tck2dat        sus2dat    e d Sch    SMBCLK    SMBDAT                            SMBSUS   STOP W  Figure 63  SMBus during suspend  Table 13  SMBus Suspend parameters  Timing Min Typical  tpar2sus Ons tens of ms  tsus2cLk Ons  tens of ns  tcLk2DAT Ons Ons  tsuswiDTH minutes  hours  weeks  tsus2DaT Ons  hundreds of ms                SMBSUS  is not a wired O
4.        General  00h through 1Fh   00h   Reserved    01h   Prepare to ARP   02h   Reset Device  general   03h   Get UDID  general    04h   Assign Address   05h   Reserved   o   o    1Fh   Reserved    Directed   e Odd numbered commands denote Get UDID from a specific  slave and are of the form yyyy yyy1b where yyyy yyyb is the  7  bit targeted slave address  For example  a command of  21h is a directed Get UDID to slave address 0010 000b     e Even numbered commands denote Reset Device to a specific  slave and are of the form yyyy yyyOb where yyyy yyyb is the  7  bit targeted slave address  For example  a command of  5Ch is a directed Reset Device to slave address  0101 110b     e Values of FEh and FFh are reserved             An ARP Enumerator is allowed to issue the    Prepare to ARP        Get UDID     general  and directed   and    Assign Address    commands  it is not allowed to issue the  Reset Device commands  It must execute the    Assign Address    command for each  device in the general    Get UDID    command using the same address that is  returned by the    Get UDID    command  A SMBus Enumerator is not allowed to re   assign addresses and it is not allowed to assign an address to a device with an  invalid uninitialized address     Devices can optionally support the    Notify ARP Master    command that is used to  notify the ARP Master that the device requires address resolution  H the ARP Master  supports this command  it must respond as a slave to this command and
5.     2 5 Conventions  2 5 1 Numeric formats  All numbers are decimal unless specifically identified otherwise   2 5 1 1 Decimal numbers  Numbers explicitly identified as decimal are identified with a suffix of    d        O 2014 System Management Interface Forum  Inc  11 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    2 5 1 2    2 5 1 3    2 5 1 4    2 5 2    2 5 3       Binary numbers   Numbers in binary format are indicated by a suffix of    b     Unless otherwise indicated    all binary numbers are unsigned    Binary numbers with more than four bits are shown in groups of four bits    All signed binary numbers are two s complement    Hexadecimal numbers   Numbers in hexadecimal format are indicated by a suffix of    h       Hexadecimal values with more than four digits are shown in groups of four digits    Examples   255d  FFh    1111 1111b   175d amp  AFh    1010 1111b   16 777 215d    FF FFFFh  amp  1111 1111 1111 1111 1111 1111b  SMBus addresses  Throughout this document  SMBus addresses are given in binary format  SMBus  addresses are 7 binary bits long and are conventionally expressed as 4 bits  followed by 3 bits followed by the letter    b     for example  0001 110b  These  addresses occupy the high seven bits of an eight bit field on the bus  The low bit of  this field  however  has other semantic meaning that is not part of a SMBus address   Transaction protocol diagrams  SMBus transaction protocol diagrams illustrate the fl
6.    do not use in ARPable devices  0001b SMBus 1 1  do not use in ARPable devices  0010b Reserved   0011b Reserved   0100b SMBus Version 2 0   0101b SMBus Version 3 0             All other values reserved    Note  The values 0000b and 0001b in the SMBus Version field  bits  3 0    support use of the UDID definition in other specifications     SubSystem IDs    The SubSystem Vendor ID can be specified as 0000h if the SubSystem fields  are unsupported  If the SubSystem Vendor ID is 0000h  the SubSystem Device ID  must also be 0000h  These fields may not be supported for inexpensive or generic  type sensors that do not require subsystem identification differentiation  If these  fields are supported  it is required that the values be stored in some form of non   volatile storage     Vendor specific ID    This field is used to provide a unique ID for functionally equivalent devices  This  is for devices that would otherwise return identical UDIDs for the purpose of address  assignment  This field is defined by the device manufacturer  as specified by the  Vendor ID field  who may employ a central numbering scheme or a random  number scheme for dynamic address devices  The data in this field is irrelevant for  devices that do not support dynamic addressing     The rules of this field are stated here for clarity     1  Devices that support an assigned device address must support a unique ID in  this field     2  If apre assigned unique ID is used  at least 16 bits must be unique  Howe
7.   Figure 44  Read 32 Protocol  tii AE he eet 46  Figure 45  Read 32 Protocol With PEC iii 46  Figure 46  Write 64 Protocol   ssiussss entente eset td id 47  Figure 47  Write 64 Protocol With DE  47  Figure 48  Read 64 Protocol motociclista 48  Figure 49  Read 64 Protocol With PEC sise 48  Figure SU UD Ds ed e a o e 49  Figure 51  8 bit device capabilities field    50  Figure 52  Version Revision field    sr 50  Figure 53  Interface field sise 51  Figure 54  Prepare to ARP command    sienne 55  Figure 55  Reset device command iii 56  Figure 56  Get UDID  general  command    is 56  Figure 57  Assign address command sise 58  Figure 58  Get UDID  directed  command    sis 59  Figure 59  Reset device ARP  directed  command ss 59  Figure 60  Notify ARP Master command usine 60  Figure 61  ARP master behavior flow diagram ss 63  Figure 62  ARP capable device behavior sis 67  Figure 63  SMBus during suspend    iii 72  Figure 64  Using SMBus to Resume from Guspend  cnn nn cnn cnn cnn rn 73  Figure 65  A 7 bit Addressable Device responds to an ARA conoccccnonocccccononcncnnnncnnnnnncncnnnnn cnn nana ncccnnns 74  Figure 66  A 7 bit Addressable Device responds to an ARA with PE  74  Figure 67  Showing SMBDAT Remaining Stable Until SMBCLK Is Low    83  O 2014 System Management Interface Forum  Inc  6 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Figure 68  PC Style Data Hold Time Specification And Implementation     ooooonninnnnnnnnicncnnnnncnnna
8.   If there is a match then it proceeds to step 11   otherwise it must return to step 7 and wait for another SMBus packet     The device has received a packet addressed to its core function so it  acknowledges the packet and processes it accordingly  Proceed to step 7 and  wait for another SMBus packet     The device detected a packet addressed to the SMBus Device Default  Address  It must check the command field to determine if this is the    Prepare  To ARP    command  If so  then it proceeds to step 13  otherwise it proceeds to  step 14     Upon receipt of the    Prepare To ARP    command the device must acknowledge  the packet and make sure its Address Resolved flag is clear in order to  participate in the ARP process  Proceed to step 7 and wait for another  SMBus packet     The device checks the command field to see if the    Reset Device    command  was issued  If so  then it proceeds to step 15  otherwise it proceeds to step 16        2014 System Management Interface Forum  Inc  64 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    15  Upon receipt of the    Reset Device    command the device must acknowledge  the packet and make sure its Address Valid  if non PSA  and Address  Resolved flags are cleared  This will allow the ARP Master to re assign all device  addresses without cycling power  Proceed to step 7 and wait for another SMBus  packet     16  The device checks the command field to see if the    Assign Address     command w
9.   on the bus the device should release  the bus line letting it be pulled high by the bus pull up circuitry     The bus lines may be pulled high by a pull up resistor or by a current source  In cases  that involve higher bus capacitance  a more sophisticated circuit may be used that can  limit the pull down sink current while also providing enough current during the low to   high transition to maintain the rise time specifications of the SMBus     VBus L Von         SMBCLK    SMBDAT    Exponential Linear  signal rise signal rise    Figure 3  SMBus pull up circuitry  4  Layer 1     The Physical Layer    4 1 Electrical Characteristics Of SMBus Devices     Two Discrete Worlds    The SMBus is expected to operate in at least two different mutually exclusive  environments that have different electrical requirements  In one case  SMBus must    O 2014 System Management Interface Forum  Inc  15 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    operate reliably in the traditional low power environment of the battery devices that  are at its roots  lt must also operate reliably in the higher noise environment of  computers and network equipment with devices that may be on the same board or on a  mezzanine card  perhaps connected through a PCI connector  This specification meets  these needs by providing two classes of electrical characteristics as called out below   Most of these specifications deal with voltage levels  noise margins  etc  Of cours
10.  1  S   Slave Address  0001 000b   Wr  A   Device Address  1100 001b    0   A       8 1 8 1  Data Byte Low  0000 0000b    A   Data Byte High  0000 0000b   A   P       Figure 60  Notify ARP master command  Implementation notes    A SMBus ARP Master in a Hot Plug System will typically not require the host  notify command as it gets asynchronous indication of a device added or  removed via other means  though there s no restriction in this specification  against using this notification in those types of applications     A mobile system that has addition and removal of devices on the SMBus can  benefit from this command if the SMBus ARP Master and the removable devices  support this command   Note  there could be one device in the system that  performs the notify on behalf of other devices  System software must always run  the FULL ARP process      ARP execution    The ARP Master must always execute the ARP when it enters the working state  and anytime it receives a SMBus status change indication  device added or  removed     e g  hot plug   The process begins with the ARP Master issuing the     Prepare To ARP    command  In all cases the ARP Master must be able to resolve  addresses when it receives the    Notify ARP Master    command     If the possibility exists that SMBus devices may join the system without a  corresponding system reset  for example in hot plug capable systems   the ARP  Master may optionally choose to issue the Get UDID  General  command at least  once every
11.  10 seconds in order to discover newly added devices that require  address resolution but that don   t support the    Notify ARP Master    command  No  device whose AR flag is clear will respond to this command  However  a newly  added device will enter the system with a power on reset  which will reset its AR flag   It will respond to a Get UDID  General  command with its UDID  The host may  choose to assign such a newly added device a non conflicting address or it may  choose to re ARP the entire bus     O 2014 System Management Interface Forum  Inc  60 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    The ARP Master or any other SMBus master can perform device    discovery    or     enumeration    by executing a subset of the ARP  This is accomplished by issuing  the    Prepare To ARP    command followed by repeatedly issuing the general    Get  UDID    and    Assign Address    commande until no device acknowledges  Until the  ARP process is complete the ARP Master must not wait more than two seconds  before issuing a general    Get UDID    command after issuing the previous general     Get UDID    command  This restriction is important to allow another SMBus  master to determine when it is safe to do an enumeration of the bus     6 6 3 11 ARP master behavior  Referring to the flow diagram in Figure 61 the ARP Master operates as follows     1     D    10     11     12     13     Upon starting  the ARP Master will initialize its Used A
12.  Figure 55  Reset device command  Get UDID  general   Action  if  AR   0  then ACK PROCESS  else NACK REJECT   AR Flag  NO CHANGE  AV Flag  NO CHANGE           This command requests ARP capable and or Discoverable devices to return their  slave address along with their UDID  If the ARP Master detects that any of the first  three bytes have not been acknowledged then it can assume that there are no ARP     capable or Discoverable devices present on the bus or all ARP capable devices  have valid assigned slave addresses     This command utilizes the standard SMBus Block Read Protocol with PEC as  illustrated below     NOTES  e Bit O  LSB  in the Data17 field must be returned as 1b     e Ifa device has its AV flag clear then it must return 1111 111b for the  remaining bits in the Data17 field     7 1 1 7 1 1       S Address  1100 001b     Wr  A   Command  0000 0011b    1 MA    eee    1 8    7 1 1  Address  1100 001b  Byte Count  0001 0001b   A     8    1    Data 1  UDID Byte 15  A    8 1  Data 2  UDID Byte 14  A    8  Data 3  UDID Byte 13        8    1    8    8       Data 4  UDID Byte 12  A    8  Data 7  UDID Byte 9  Data 8  UDID Byte 8  Data 9  UDID Byte 7  A  8       1  Data 5  UDID Byte 11  A    8 1    8 1    Data 6  UDID Byte 10     8    8    1    1       Data 10  UDID Byte 6  Data 11  UDID Byte 5  Data 12  UDID Byte 6  Af    8    Data 13  UDID Byte 3  A Data 14  UDID Byte 2  Data 15  UDID Byte 1  A    1  A  1  A  1       8 1    8    1          8 1 8 1 8 1  Data 16  UDID By
13.  Per Bus Segment  200 200  200 200  200 200 uA  ILEAK PIN Input Leakage Per Device Pin  10 10  10 10  10 10 uA  Laus Capacitive Load Per Bus Segment       400   400 pF  Coin Capacitance For SMBDAT Or SMBCLK Pin       10   10 pF  Recommended     2014 System Management Interface Forum  Inc  26 of 85    All Rights Reserved       System Management Bus  SMBus  Specification Version 3 0    4 3 4 1    4 3 4 2    4 3 5  4 3 5 1    4 3 5 2    Capacitive load of High Power SMBus lines    Capacitive load for each bus line includes all pin  wire and connector  capacitances  The maximum capacitive load affects the selection of the Rp pull   up resistor or the current source in order to meet the rise time specifications of  SMBus     Pin capacitance  Cp  is defined as the total capacitive load of one SMBus  device as seen in a typical manufacturer s data sheet  The value is a recommended  guideline so that two such devices may  for example  be populated on an add in  card     Minimum current sinking requirements for SMBus devices    SMBus devices used in Low Power segments have practically no minimum current  sinking requirements due to the low pull up current specified for Low Power  segments     Devices in High Power segments are required to sink a minimum current while  maintaining the Vo  max of 0 4 volts  The minimum current depends on the maximum  bus clock speed and is specified to assure that the rise time specification can be met  with a resistive pull up at the minimum Vpp  maxim
14.  Std PC mode 100 kHz Class  Symbol   Parameter device SMBus device   Units  Comments  Min Max Min Max  VoL LOW level output         0 4 V Ilo   3 mA  DEES 0 4   3 lo     4 mA  loL LOW level output  3             mA  Vo   0 4V  current  lLeak 8us   Input leakage per bus      200 200 UA  Segment  Con Capacitance for clock or     10         pF  data pin  Cous Capacitive load per bus     400         pF  segment  foma  fsc    Bus operating frequency     100 10 100 kHz  tnmeour Detect clock low timeout         25 35 ms  tuicH Clock high period 4 0   4 0 50 us  tLow sexr   Cumulative clock low             25 ms  extend time  slave  device   tLow mexr   Cumulative clock low             10 ms  extend time  master  device   tor Output voltage fall time     250         ns  Note 2  tr Output voltage fall time     300 300 ns  Note 3  tror Time in which a device             500 ms  must be operational  after power on reset  Table 15  DC parameter differences between  Fast mode PC and 400 kHz Class SMBus  Fast mode Plus   400 kHz Class  Symbol  Parameter PC mode device   SMBus device   Units   Comments  Min Max Min Max  Von Nominal bus voltage         1 8 5 0 V  Operating bus voltage         1 62 5 5 V Nominal  10   7 Fixed input level       0 8 V  g Vi related input level  0 5   0 3 Vi         V  Fixed input level         1 35 Vop V  V    D S  S Von related input level Del See Ne                                       2014 System Management Interface Forum  Inc     All Rights Reserved    77
15.  analyzer monitoring SMBCLK and  SMBDAT     The 12C specification   RO1    however  took a very different approach to specifying the data hold  time  In the 12C specification  the data hold time was specified as O ns  However  the PC    O 2014 System Management Interface Forum  Inc  83 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    specification added a note to the timing specification table that says for maximum bus speeds of  100 kHz and 400 kHz        A device must internally provide a hold time of at least 300 ns for the SDA signal  with  respect to the Vinimin  Of the SCL signal  to bridge the undefined region of the falling edge  of SCL        This now puts the burden of maintaining the data hold time on the device receiving data  This is  illustrated in Figure 68  In Figure 68 SMBCLK and SMBDAT represent the signal traces  between the bus devices and RXCLK and RXDAT represent the clock and data signals internal  to the receiving device at the output of the clock and data interface circuits     SMBCLK RXCLK          Receiver  Clock  Input       Transmitter SMBDAT Receiver SES    Data Data  Output Input        tHp par   O ns       texHo DAT     F MAX    Figure 68  PC Style Data Hold Time Specification And Implementation    The advantage to this way of specifying the data hold time is that the device sending data can  now toggle the clock and data lines simultaneously  This would often happen when driving an  IC bus by    bit bang
16.  between byte transfers on  the bus  in order to process received data or prepare data for transmission  In this  case the slave device will hold the clock line LOW after the reception and  acknowledgement of a byte  Again the slave device is responsible for not violating the  tLow sexr Specification of SMBus     During a bus transaction the master also can select to extend the clock LOW period  between bytes or at any point in the byte transfer  including the clock LOW period after  the byte transfer and before the acknowledgement clock  The master may need to  extend the clock LOW period selectively in order to process data or serve a real time  task  In doing so  the master must not exceed the tLow mexr Specification     Both master and slave devices must adhere to the SMBus trimeour specification in  order to maintain bus bandwidth and recovery from fatal bus conditions        2014 System Management Interface Forum  Inc  33 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    SMB    Master  Clock Output    SMB  Devi    SMBCLK    SMBDAT    5 4            EE i   Clock Output   i  H                          PAA AAR    rel      us                S             us  ce                            Condition    Figure 18  Random clock stretching    Data Transfer Formats    SMBus data transfers follow the format shown in Figure 19          AAAA AAA                SMBDAT         BIT 0  RW           BIT 7  MSB    i    BIT 6    i    BIT5  BIT 4  BIT 
17.  characteristics  network control conventions and  communications protocols used by SMBus devices  These can be thought of as  existing at the first three layers of the seven layer OSI network model  that is  the  physical  data link and network layers  Functions normally implemented at higher  layers of the OSI model are beyond the scope of this document     The original purpose of the SMBus was to define the communication link between an  intelligent battery  a charger for the battery and a microcontroller that communicates  with the rest of the system  However  SMBus can also be used to connect a wide  variety of devices including power related devices  system sensors  inventory  EEPROMs  communications devices  and more     This version of the specification is a superset of previous versions  1 0  1 1  and 2 0   The intent is that all devices compliant with these previous versions are compliant  with this version  Those features new to SMBus with this version of the specification are  optional and are appropriate to the new environments enabled by those features   However  if implemented  these new features must be implemented in a manner  compliant with this specification     1 4 Organization of this document    This document is organized to first give the reader an overview of the SMBus and  then to delve deeper into its actual workings  The major technical discussion appears  in three sections that treat the various aspects of the SMBus as they would appear in       20
18.  dal  sl dal Tei del  71 lsl lo      FREE  KIC A A AA HY    Figure 7  Clock extension measurement intervals       4 2 4 Slave device clock extension    Slave devices that violate tLow sexr are not conformant with this specification  A Master  is allowed to abort the transaction in progress to any slave that violates the tLow sexr or  ttimEOUT MIN specifications    4 2 5 SMBDAT low timeout    It is possible that a malfunctioning device holds the SMBDAT line low indefinitely  This  would prevent the master from issuing a STOP condition and ending a transaction  At  this time there is no specification on the maximum time that a device can hold  SMBDAT low after the master raises SMBCLK after the last bit of a transaction  Such  a specification is under consideration for future revisions of the SMBus specification     In the meantime  the recommendation is that if SMBDAT is still low trimeout max after  SMBCLK has gone high at the end of a transaction the master should hold SMBCLK  low for at least trimeour max in an attempt to reset the SMBus interface of all of the  devices on the bus     4 3 DC Specifications    The SMBus offers two classes of electrical interface specifications  The Low Power  specification is for systems where conservation of energy is more important that bus  speed  such as in battery powered systems  The High Power specification is used where  higher bus speeds are needed  such as in computing equipment        2014 System Management Interface Forum  Inc  2
19.  from the write byte count  M   The read byte  count  N  may be zero     The combined data payload must not exceed 255 bytes  The byte length restrictions of  this process call are summarized as follows    e M2 gt 0byte   e N2Obyte   e M N lt  255 bytes   The read byte count does not include the PEC byte  The PEC is computed on the  total message beginning with the first slave address and using the normal PEC    computational rules  It is highly recommended that a PEC byte be used with the  Block Write Block Read Process Call     Note that there is no STOP condition before the repeated START condition  and  that a NACK signifies the end of the read transfer                    7 1 1 8 1 8 1  S Address Wr A Command Code A Byte Count  N A  8 1 8 1 8 1  Data Byte 1 A Data Byte 2 A Data Byte N A P  7 1 1 8 1  Sr Address Rd MA Byte Count  N A    eee       8 1 8 1 8 1  Data Byte 1 A Data Byte 2   Data Byte N PN   P    Figure 39  Block Write   Block Read Process Call       7 1 1 8 1 8 1  Command Code Bye Count N  8 1 8 1 8 1  Data Byte 1 A Data Byte 2 A Data Byte N AJP  7 1 8 1 8 1        Ts FO  I     8 1 8 1 8 1   A     MN a    Figure 40  Block Write   Block Read Process Call with PEC  6 5 9 SMBus Host Notify protocol    To prevent messages coming to the SMBus host controller from unknown devices  in unknown formats only one method of communication is allowed  a modified form  of the Write Word protocol  The standard Write Word protocol is modified by  replacing the command code wit
20.  must accept and  check the additional PEC for validity     During a slave transmit transfer  the slave transmitter must respond to additional  clocks after the last byte transfer and furnish a PEC to the master receiver  requesting it     Each bus transaction requires a Packet Error Code  PEC  calculation by both the  transmitter and receiver within each packet  The PEC uses an 8 bit cyclic  redundancy check  CRC 8  of each read or write bus transaction to calculate a  Packet Error Code  PEC   The PEC may be calculated in any way that conforms  to a CRC 8 represented by the polynomial  C x    x     x    x    1  and must be  calculated in the order of the bits as received     Calculating the PEC for transmission or reception is implemented in a method  chosen by the device manufacturer  It is possible to perform the check with a low   cost hardware or a firmware algorithm that could process the message bit by bit or  with a byte wise look up table  The SMBus web page provides some example  CRC 8 methods     The PEC is appended to the message as dictated by the protocols in   Section 6 5  The PEC calculation includes all bytes in the transmission  including  address  command and data  The PEC calculation does not include ACK or NACK  bits or START  STOP or REPEATED START conditions  This means that the  PEC is computed over the entire message from the first START condition        2014 System Management Interface Forum  Inc  38 of 85  All Rights Reserved    System Management Bu
21.  of 85    System Management Bus  SMBus  Specification Version 3 0                                                                                              Fast mode Plus   400 kHz Class  Symbol  Parameter FC mode device   SMBus device   Units   Comments  Min Max Min Max  Vuys Hysteresis voltage of 0 05 x     0 08     V  Schmitt trigger inputs Vo  VoL LOW level output             0 4 V lo     6 mA  SE   0 4 z   V  lo   3 mA   Vop  gt 2V    0 2 x     V lou    2 mA   Von Von  lt 2V  lou LOW level output  3             mA   Vo   0 4 V  CUEN  6       mA  Voi   0 6 V  Note 4  ILEAK BUS      200 200 uA  foma   fsc    Bus operating frequency     100 10 100 kHz  trimeout Detect clock low timeout         25 35 ms  tHicH Clock high period 0 6     0 6 50 us  ttow sexr   Cumulative clock low             25 ms  extend time  slave  device   tLow mexr   Cumulative clock low             10 ms  extend time  master  device   tor Output voltage fall time 20 x 250         ns   Vpp 5  Note 2  5 V   tr Output voltage fall time 20 x 300     300 ns   Vop 5    Note 2 Note 3  5 V    tror Time in which a device             500 ms  must be operational  after power on reset  Table 16  DC parameter differences between  Fast mode Plus DC and 1 MHz Class SMBus  Fast mode Plus   1 MHz Class  Symbol  Parameter FC mode device SMBus device   Units   Comments  Min Max Min Max  Vop Nominal bus voltage     1 8 5 0 V  Operating bus voltage         1 62 5 5 V Nominal  10   Vi Fixed input level             0 8 V  
22.  provide a  software indication that the ARP needs to be executed                       6 6 3 1 Device categorization  SMBus devices are categorized as given in Table 11   Table 11  SMBus device characterizations  Field Description  ARP capable Device supports all ARP commands with the exception of  the optional host notify command  Slave address is  assignable  Device supports both Reset commands      2014 System Management Interface Forum  Inc  54 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0       Field Description       Fixed and Discoverable Device supports the Prepare to ARP  directed Get UDID     general Get UDID and Assign Address commands  Slave  address is fixed  device will acceptthe Assign Address  command but will not allow address reassignment  Device  supports both Reset commands        Fixed  not Discoverable Device supports the directed Get UDID command  Slave    address is fixed        Non ARP capable Device does not support any ARP commands  Slave       address is fixed                 6 6 3 2 Prepare to ARP  Action  always ACK PROCESS  AR Flag  CLEAR  AV Flag  NO CHANGE  This command informs all devices that the ARP Master is starting the ARP process   All ARP capable devices must acknowledge all bytes in this SMBus packet and clear  their Address Resolved  AR  flag  They must also cancel any pending    Notify ARP  Master    commande If the ARP Master detects that any of the bytes have not been  acknowledged then i
23.  that any of the first three bytes have not been  acknowledged then it can assume that no ARP capable device is present at the  targeted slave address     This command utilizes the standard SMBus Block Read Protocol with PEC as  illustrated below     NOTES  Bit O  LSB  in the Data17 field must be returned as 1b        2014 System Management Interface Forum  Inc  58 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    7 1 il 7 1 1    7 1 1 8    Sr  Address  1100 001b   Rd  A Byte Count  0001 0001b           8 1 8 1 8 1  Data 1  UDID Byte 15  A Data 2  UDID Byte 14  A Data 3  UDID Byte 13  A  8 1 8 1 8 1       Data 4  UDID Byte 12  A Data 5  UDID Byte 11  A Data 6  UDID Byte 10  A           8 1 8 1 8       Data 7  UDID Byte 9  A Data 8  UDID Byte 8  A Data 9  UDID Byte 7  A    8 8 8 1    1 1  Data 10  UDID Byte 6  A Data 11  UDID Byte 5  Data 12  UDID Byte 6     8 1 8 1 8    i  Data 13  UDID Byte 3  A Data 14  UDID Byte 2  Data 15  UDID Byte 1     8 1 8 1 8  Data 16  UDID Byte 0  A   Data 17  Device Slave Address    A PEC Byte    a   nel          Note  Bit  0   LSB  in the Data 17 Field Must Be Returned As 1     6 6 3 7    Figure 58  Get UDID  directed  command  Reset device ARP  directed   Action  if  AV   1  then ACK PROCESS  else NACK REJECT   AR Flag  CLEAR  AV Flag  if  non PSA  then CLEAR  else NO CHANGE    This command forces a specific non PSA  ARP capable device to return to its initial  state  That is  it must clear its AR and AV fl
24.  the received packet was the    Notify ARP  Master    command  If so  then it must execute the ARP to resolve the address  for the newly added device s   proceed to step 6  If not  then proceed to step  16     16  The ARP Master received a non ARP related packet  Process it accordingly  and proceed to step 5     The ARP Master behavior flow diagram covers the case when the ARP Master  has come out of a reset state  The ARP supports    hot plug    devices so the ARP  Master must be prepared to execute the ARP at any time  step 15 covers the case  when a device a device issues the    Notify ARP Master    command  Since that  command is optional the ARP Master cannot rely on a notification from the device  upon its appearance on the SMBus  As such the ARP Master should periodically  issue the    Prepare To ARP    command if the SMBus implementation supports    run   time    device addition  Doing so will also allow the ARP Master to determine if any  ARP capable devices have been removed from the SMBus  In this case the ARP  Master can remove addresses from the Used Address Pool if it doesn   t detect a  response from a device previously assigned an address     The flow diagram also does not cover consideration for bus timeout mechanisms  or retries  These should be implemented in order to comply with the bus timing  specifications        2014 System Management Interface Forum  Inc  62 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Reset
25.  transmitter wants to be sure that a write operation is performed  correctly at the target device  it must use some higher layer mechanism to verify  this  This might take the form of a read with PEC of the data  receipt of a correct  PEC would reliably indicate that that the original write occurred without error     When a master receiver reads data from a slave transmitter  the ACK NACK  supplied by the master receiver at the end of the transaction has little meaning  other than to mark the end of the last byte  The slave transmitter is supplying the  data  and if the PEC supplied by the slave transmitter is correct  the master   receiver may assume that the data was received as the slave transmitted it  If not  it  is up to the master receiver to take any appropriate remedial action     Master implementation    A master may use PEC on any transaction  lt is required that the master have either a  priori knowledge of whether or not the target slave supports PEC or a way to  determine whether the target slave supports PEC  The use of PEC is governed  by upper layer protocols  e g  device drivers   specifications  e g  requirements of  the SMBus ARP protocol  or detection algorithms for a given class of devices  e g   smart batteries      Slave implementation    A slave device that implements Packet Error Checking must be prepared to  receive and transmit data with or without a PEC  During a slave receive transfer   after the device has identified the protocol and command  it
26.  up to 64 bits  8  bytes  of data from a slave device     This protocol can be used to send less than 64 bits but the packet must be padded to  fill 64 bits  Data or meaningful bits are packed into the lower order bits and unused  higher order bits are filled with zeros  For example  a 40 bit value is transmitted in bits   39 0  with the most significant bit in bit  39   Bits  63 40  are all zeros        2014 System Management Interface Forum  Inc  47 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0               S   Address  we  Command Code  A om  7 de A 8 1  pes     TN      8 1 8    Data Byte 2  Bits  15 8   A Data Byte 3  Bits  23 16   A       8 1 8  Data Byte 4  Bits  31 24   A Data Byte 5  Bits  39 32   A    8 1 8  Data Byte 6  Bits  47 40   A Data Byte 7  Bits  55 48   A          8 1  Data Byte 8  Bits  47 40                    P    Figure 48  Read 64 Protocol       7 1 8 1  7 1 1 8 1   Sr Address Rd  A      DataByte1 Bits 70   A            8 1 8 1  Data Byte 2  Bits  15 8   A   Data Byte 3  Bits  23 16   be  i    8 1 8    Data Byte 4  Bits  31 24   A  Data Byte 5  Bits  39 32   A           8 1 8 1  Data Byte 6  Bits  47 40   A  Data Byte 7  Bits  55 48   Sr       8 1 8  Data Byte 8  Bits  47 40     A PEC Byte NTP          Figure 49  Read 64 Protocol With PEC    6 6 SMBus Address Resolution Protocol    SMBus slave address conflicts can be resolved by dynamically assigning a new  unique address to each slave device  The Address Resol
27. 0b to the Used Address Pool  since Device B acknowledged the packet     5  The ARP Master will issue the    Get UDID    command again        2014 System Management Interface Forum  Inc  69 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    6  Device C having lost the previous arbitration will respond and will transmit the  byte count for this command without collision  Since it is now the only device  responding all remaining bytes will be transmitted without collision    7  Device C will await an assigned address since its Address Valid flag is  cleared    8  The ARP Master recognizes that the returned slave address field was FFh  It  captures the returned UDID and selects an address  e g  1001 010b  not in the  Used Address Pool and issues the    Assign Address    command    9  All devices will monitor the    Assign Address    command looking for a UDID  match  Since Device C will match its UDID it will acknowledge the packet and  adopt the slave address assigned by the ARP Master  Device C will also set  its internal Address Resolved and Address Valid flags and will no longer  respond to the    Get UDID    command until it receives the    Prepare To ARP    or     Reset Device    commands or is power cycled    10  The ARP Master will add slave address 1001 010b to the Used Address Pool  since Device C acknowledged the packet    11 The ARP Master will issue the    Get UDID    command again    12  Since all three devices have their intern
28. 14 System Management Interface Forum  Inc  8 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    the first three layers of the OSI reference network model  the physical layer  the data  link layer and the network layer     The section on the physical layer sets out SMBus electrical characteristics  The section  on the data link layer specifies bit transfers  byte data transfers  arbitration  and clock  signals  The section on the link layer deals with the general usage model  the concept  of addresses in SMBus  the Address Resolution Protocol and the bus data transfer  protocol  All aspects of the SMBus proper may be described within the scope of the  first three OSI layers     The SMBus is a multiple attachment bus with no routing capability  Most  communication occurs between and involves only two nodes  a master and a slave   Exceptions to this rule occur during and apply to devices that implement the Address  Resolution Protocol as well as the Alert Response Address     Appendixes at the end of this document contain additional information and guides to  implementation that the reader may find useful     2  Related Documents And Reference Information    2 1 Scope    If the requirements of this specification and any of the reference documents are in  conflict  this specification shall have precedence unless otherwise stated     Referenced documents apply only to the extent that they are referenced     The latest version and all amendment
29. 2 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    4 3 1 Supply voltage requirements    Both the Low Power and High Power classes specify that the nominal supply voltage  of devices attached to the bus may range from 1 8 V  1 62 V minimum  to 5 0 V  5 5  V maximum      This does not mean that a SMBus device must operate with any supply in the range  of 1 62 V to 5 5 V  A device manufacturer may choose any operating voltage or  operating voltage within the specified limits  The operating voltage range must be  given in the device data sheet     There is no requirement that all devices on a SMBus be powered from the same  supply voltage or supply voltages of the same value  If devices with different supply  voltages are used  as shown in Figure 8  the SMBus signals  SMBCLK  SMBDAT   and SMBALERTH  if present  must be pulled up to the highest supply voltage  or a  voltage equal to the highest supply voltage  of any device attached to the bus     This means that the I O circuits for the SMBus signals  SMBCLK  SMBDAT  and  SAMBALERT   if present  must withstand  without damage or degradation  the  voltage on the signal pin being pulled up to 5 5 V     Von Voo2       SMBCLK    SMBDAT    Note  Von  2 Vop2   Note  All Rs Are Optional    Figure 8  SMBus branch with multiple devices attached  4 3 2 SMBus branch circuit model    Figure 9 shows the electrical model of the SMBus  A series protection resistor  can be used for ESD protection of compon
30. 3  BIT 2  BIT 1  BIT5  BIT 4  BIT 3  BIT2  BIT 1  BIT 0  LSB    BIT 7  MSB  N  BIT 6       Condition          GERERE  OOOO f    Destination Address Das Condition  Figure 19  Data transfer over SMBus    After the START condition     S      the master places the 7 bit address of the slave  device it wants to address on the bus  The address is 7 bits long followed by an eighth  bit indicating the direction of the data transfer  R W    a ZERO indicates a transmission   WRITE  while a ONE indicates a request for data  READ   A data transfer is always  terminated by a STOP  P  condition generated by the master     Specific SMBus protocols require the master to generate a repeated START  condition followed by the slave device address without first generating a STOP  condition     6  Layer 3     Network layer    6 1    6 1 1       2014    Usage Model    Three different types of devices are referred to in this specification  masters  slaves   and hosts     Master devices    A master device issues commands  generates the clocks  and terminates the transfer   Depending on the transaction type  a master in a transaction may transmit data to a  slave device  master transmitter  or it may receive data from a slave device  master   receiver      System Management Interface Forum  Inc  34 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    A device may be designed to be a master only or it may be a master slave  in which  it can act either as a master d
31. Bye Count N  8 1 8  Data Byte 1 A Data Byte 2  8 1 8  Data Byte N A PEC Byte AJP             Figure 36  Block Write with PEC    A Block Read differs from a Block Write in that the repeated START condition  exists to satisfy the requirement for a change in the transfer direction  A NACK  immediately preceding the STOP condition signifies the end of the read transfer     7 1 1 8    1    7 1 vi 8         8 1 8 1 8 1    Data Byte 1 Data Byte 2 Data Byte N    Figure 37  Block Read    un             7 1 1 8 1  S Address Wr MA Command Code A Geh  7 1 1 8 1 8  Sr Address Rd MA Block Count  N A Data Byte 1 A  8 1 8 1 8 1       S A PEC Bye  e  Figure 38  Block Read with PEC  6 5 8 Block Write Block Read Process Call    The Block Write Block Read Process Call is a two part message  The call begins  with a slave address and a write condition  After the command code the host  issues a write byte count  M  that describes how many more bytes will be written in  the first part of the message  If a master has 6 bytes to send  the byte count field will  have the value 6  0000 0110b   followed by the 6 bytes of data  The write byte count   M  may be zero     O 2014 System Management Interface Forum  Inc  43 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    The second part of the message is a block of read data beginning with a repeated  start condition followed by the slave address and a Read bit  The next byte is the  read byte count  N   which may differ
32. DIDs  Since the UDIDs are equal through  the first seven most significant bytes there will be no bus collisions  The eighth  UDID byte will be transmitted as follows    Device B  1110 0000 11100000  Device C  1110 0001 11100001    Seen on the bus  E 11000 O 0 Device B wins the bus arbitration       Device B wins the bus arbitration since it is transmitting a    O    as the last bit in the  eighth byte of the UDID whereas Device C is transmitting    1     As such Device C  will cease transmission of this packet  Device B will complete its transmission by  sending the remaining eight bytes of the UDID and an FFh for the Device Slave  Address field since its Address Valid bit is cleared    1  Device B will await an assigned address since its Address Valid flag is  cleared    2  The ARP Master recognizes that the returned slave address field was FFh  It  captures the returned UDID and selects an address  e g  1001 000b  not in the  Used Address Pool and issues the    Assign Address    command    3  All devices will monitor the    Assign Address    command looking for a UDID  match  Since Device B will match its UDID it will acknowledge the packet and  adopt the slave address assigned by the ARP Master  Device B will also set  its internal Address Resolved and Address Valid flags and will no longer  respond to the    Get UDID    command until it receives the    Prepare To ARP    or     Reset Device    commands or is power cycled     4  The ARP Master will add slave address 1001 00
33. Emi    System Management  Interface Forum       System Management Bus   SMBus   Specification    Version 3 0    20 Dec 2014    www powerSIG org    O 2014 System Management Interface Forum  Inc      All Rights Reserved    Filename  SMBus 3_0_20141220 docx  Last Saved  20 December 2014 19 59    System Management Bus  SMBus  Specification Version 3 0    This specification is provided    as is    with no warranties whatsoever  whether express  implied or  statutory  including but not limited to any warranty of merchantability  non infringement or fitness  for any particular purpose  or any warranty otherwise arising out of any proposal  specification  or sample     In no event will any specification co owner be liable to any other party for any loss of profits   loss of use  incidental  consequential  indirect or special damages arising out of this  specification  whether or not such party had advance notice of the possibility of such damages   Further  no warranty or representation is made or implied relative to freedom from infringement  of any third party patents when practicing the specification     Other product and corporate names may be trademarks of other companies and are used only  for explanation and to the owner s benefit  without intent to infringe                       Revision No  Date Notes Editor  1 0 2 15 95 General Release Unknown  1 1 12 11 98 Version 1 1 Release Unknown  2 0 8 3 00 Version 2 0 Release Unknown  3 0 20 Dec 2014   Version 3 0 Release Robert V  W
34. If the Address Valid flag is cleared then it  must proceed to step 3   Although the device supports the PSA the value is currently invalid  The  device must clear the Address Resolved flag indicating that it has not had its  slave address assigned  Proceed to step 6       The device has a valid PSA so it assumes that slave address for now     However  this address has not been resolved by the ARP Master so the  device must clear its Address Resolved flag  Proceed to step 6     The device does not support the PSA so it must clear its Address Valid and  Address Resolved flags  Proceed to step 6     If supported  the device will master the SMBus and send the    Notify ARP  Master    command  This will inform the ARP Master that a new device is  present  Proceed to step 7     The device waits for a SMBus packet     Upon receipt of a SMBus packet the device must first check the received slave  address against the SMBus Device Default Address  If there is a match then it  proceeds to step 12  otherwise it proceeds to step 9     The received address is not the SMBus Device Default Address so the  packet is potentially addressed to the device   s core function  The device must  check its Address Valid bit to determine whether or not to respond  If the  Address valid bit is set then it proceeds to step 10  otherwise it must return to  step 7 and wait for another SMBus packet     Since the device has a valid slave address it must compare the received slave  address to its slave address
35. R signal  It is an output from the device that controls system  management functions  and an input to everything else     During suspend there is no activity on the System Management Bus unless the SMBus is used  to resume from suspend mode  Activity resumes after coming out of suspend        2014 System Management Interface Forum  Inc  72 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Any time after a STOP condition the SMBSUS  signal may go active low signifying the system  is going into Suspend Mode  This can happen immediately  min   0 ns   but will probably take  much longer  In fact  the final SMBus message might terminate minutes or hours before  SMBSUS  goes low  Suspend Mode could last a couple of seconds  minutes  hours  or weeks   Before the System Management Bus can send another message the system must come out of  Suspend Mode  a process known as Resume  The resume process probably has to supply  voltage to the System Management Bus anyway  although the SMBus may be awake during  suspend  The resume process can take a long time  perhaps hundreds of milliseconds  Careful  power down sequencing of the SMBCLK and SMBDAT pull ups will prevent devices from  falsely seeing a START condition on the bus     If power is supplied to the System Management Bus during suspend  a device may use it to  awaken the system  The host or another device will watch for a START condition on the bus   That device initiates the resume sequence  C
36. R01   0000 011 X  Reserved for future use 12C Bus Specification And User Manual   R01   0000 1XX X  HS Mode Master Code 12C Bus Specification And User Manual   R01   0001 000 X   SMBus Host System Management Bus Specification  V 1 1  December 1998  0001 001 X   Smart Battery Charger Smart Battery Charger Specification  V 1 1  December 1998  0001 010 X   Smart Battery Selector Smart Battery Selector Specification  Smart Battery System Manager V 1 1  December 1998  Smart Battery System Manager  Specification V 1 0B  August 1999  0001 011 X   Smart Battery Smart Battery Data Specification V 1 1   December 1998  0001 100 X   SMBus Alert Response Address System Management Bus Specification  V 1 1  December 1998  0101 000 1 PMBus    ZONE READ PMBus Power System Management  Protocol Specification  Part    Revision  1 3  0101 100 X   Reserved by previous versions of the  SMBus specification for LCD Contrast  Controller  This address may be  reassigned in future versions of the  SMBus specification   0101 101 X   Reserved by previous versions of the             SMBus specification for CCFL Backlight  Driver  This address may be reassigned  in future versions of the SMBus  specification           O 2014 System Management Interface Forum  Inc   All Rights Reserved    81 of 85       System Management Bus  SMBus  Specification Version 3 0                                        Slave  Address GC Description Specification  Bits  7 1   0110 111 0 PMBus    ZONE WRITE PMBus Power System Manage
37. W level input voltage for   0 8 V  SMBCLK and SMBDAT  VoL Low level output voltage for   0 4 V llo    350 pA  SMBCLK and SMBDAT    LEAK PIN Input leakage current per device    5 5 UA  Note 1  pin  IPULLUP Current through pull up resistor or 100 350 uA  Note   from pull up current source             Note 1  Devices must meet this specification whether powered or unpowered   However  a microcontroller acting as a SMBus host may exceed lLeax pin by no more  than 10 pA     O 2014 System Management Interface Forum  Inc  24 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Note 2  The Iputtup max Specification is determined primarily by the need to  accommodate a maximum of 1 1 kQ equivalent series resistor of removable SMBus  devices  such as the Smart Battery  while maintaining the Vo  max of the bus     Because of the relatively low pull up current  the system designer must ensure that  the loading on the bus remains within acceptable limits  Additionally  to prevent bus  loading  any devices that remain connected to the active bus while unpowered  that  is  their Voo lowered to zero   must also meet the leakage current specification     It is the responsibility of the system designer to ensure that all SMBus components  comply with the SMBus timing requirements and are able to operate within the  voltage requirements of the specific system     Components attached to SMBus may operate at different voltages  Therefore the  SMBus cannot assum
38. a transfer  the master  generates a REPEATED START condition and the slave address but with the R W   set to 1  In this case the master receiver terminates the transfer by generating a  NACK on the last byte of the transfer and a STOP condition     Examples of these formats will be seen in the SMBus protocols below   Quick Command    In the Quick Command the R W  bit of the slave address denotes the command   The R W  bit may be used to simply turn a device function on or off  or enable disable  a low power standby mode  There is no data sent or received     The Quick Command implementation is good for very small devices that have  limited support for the SMBus specification  It also limits data on the bus for simple  devices     7 1 1  EA O A  Figure 20  Quick Command protocol  Send Byte    A simple device may recognize its own slave address and accept up to 256  possible encoded commands in the form of a byte that follows the slave address     All or parts of the Send Byte may contribute to the command  For example  the  highest 7 bits of the command code might specify an access to a feature  while the  least significant bit would tell the device to turn the feature on or off  Or  a device    O 2014 System Management Interface Forum  Inc  39 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    may set the    volume    of its output based on the value it received from the Send Byte  protocol     7 1 8 1    S ms M e LU    Figure 21  Send By
39. address 1001 001b to the Used Address Pool  since Device A acknowledged the packet     10  The ARP Master will issue the    Get UDID    command again     11  Device B having lost the previous arbitration will respond and will transmit the  byte count for this command without collision  Since it is now the only device  responding all remaining bytes will be transmitted without collision    12  The ARP Master recognizes that the returned slave address was already in  the Used Address Pool  It captures the returned UDID and selects an address   e g  1001 000b  not in the Used Address Pool and issues the    Assign Address     command     13  All devices will monitor the    Assign Address    command looking for a UDID  match  Since Device B will match its UDID it will acknowledge the packet and  adopt the new slave address assigned by the ARP Master  Device B will keep  its internal Address Valid flag set and will set its Address Resolved flag so that it  will no longer respond to the    Get UDID    command until it receives the    Prepare  To ARP    or    Reset Device    commands or is power cycled     14  The ARP Master will add slave address 1001 000b to the Used Address Pool  since Device B acknowledged the packet     15  The ARP Master will issue the    Get UDID    command again    16  Since both devices have their internal Address Resolved flag set they will not  respond    17  The ARP Master will detect that no device has acknowledged the packet and  will terminate the ARP 
40. ags  if the device supports the  Persistent Slave Address it must clear its AR flag  An ARP capable device that  implements a random number as part of its UDID must regenerate its random  number upon receipt of this command  If the ARP Master detects that any of the  bytes have not been acknowledged then it can assume that no ARP capable  device is present at the targeted slave address     This reset is just for the ARP functions  and is not intended as a general device  reset     This command utilizes the standard SMBus Send Byte Protocol with PEC as  illustrated below     7 1 1 8 1 1 8 1     5  Sive NC RE EL To A recae LU    Figure 59  Reset device ARP  directed  command       2014 System Management Interface Forum  Inc  59 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    6 6 3 8    6 6 3 9    6 6 3 10    Notify ARP master       device may use this command to notify the ARP Master that the device   requires address resolution  The device may execute this command under the   following circumstances    e Device power up   e When the device senses a bus collision during a read operation directed to  its Assigned Slave Address     This command utilizes the standard SMBus protocol to communicate with the Host   at the SMBus Host Address as defined in Table 17 in Appendix C  as illustrated  below     Note  The value of 0000h in the data field means that the device wishes to be  ARPed  All other values are reserved for future use   7 1 1 7 1
41. al Address Resolved flag set they will  not respond    13  The ARP Master will detect that no device has acknowledged the packet and  will terminate the ARP    Example 2    In this scenario assume the following     The system is in the S5 state     The system does not contain any devices with slave address values 1001  000b  1001 001b       1001 111b     Device A has a UDID of 0123 4567 89AB CDEF 0000 0000 0000 0000h  does  support the Persistent Slave Address and was previously assigned the slave  address 1001 001b  Device A was present in the system before it entered the  S5 state  lts Address Valid flag is set but its Address Resolved flag is  cleared    New Device B has a UDID of FEDC BA98 7654 3210 0000 0000 0000 0000h   does support the Persistent Slave Address and was previously assigned the  slave address 1001 001b when present in another system  Device B was  added to the system while it was in the S5 state  Its Address Valid flag is set  but its Address Resolved flag is cleared     Both devices exit their power on reset state at the same time     The ARP will proceed as follows     1     2     3     The system transitions to the SO state  assume the user pressed the power  button     The ARP Master will exit the reset state and will initialize its Used Address  Pool    When the devices exit their power on reset state they may attempt to issue the     Notify ARP Master    command  assume that they do for this example  The  ARP Master will attempt to issue the    Prep
42. alues  are simple examples for illustrative purposes  They do not necessarily represent  legal values     Example 1  In this scenario assume the following     e The ARP Master has already exited its reset state and has run the ARP  The  Used Address Pool does NOT contain the values 1001 000b  1001 001b         1001 111b     e New Device A has a UDID of 8123 4567 89AB CDEF 0000 0000 0000 0000h   does support the Persistent Slave Address and was previously assigned the  slave address 1001 001  Its Address Valid flag is set but its Address  Resolved flag is cleared    e New Device B has a UDID of F123 4567 89AB CDEO 0000 0000 0000 0000h  and does not support the Persistent Slave Address  Its Address Valid and  Address Resolved flags are cleared    e New Device C has a UDID of F123 4567 89AB CDE1 0000 0000 0000 0000h  and does not support the Persistent Slave Address  Its Address Valid and  Address Resolved flags are cleared     e All devices exit their power on reset state at the same time     The ARP will proceed as follows     1  When the devices exit their power on reset state they will optionally attempt  to issue the    Notify ARP Master    command  Assume for this example that all  three devices do so     2  All devices will transmit all bytes of the    Notify ARP Master    command without  collision     3  The ARP Master having received the    Notify ARP Master    command will  issue the    Get UDID    command     4  After detecting the repeat Start condition and receivin
43. ar ee oie pai eee Gee alta tnt ee a 39  6 5 1 Quick  Command  ss ii nue ed a ee eee eae Or 39   6 5 2 Send Byte ise  ugeet den teenie e aa ee AE 39   6 5 3 Receive  Bytes aa ee Aw a i eae a en a ee ak 40   6 5 4 VIC e te EE 40   6 5 5 Read Byt   Mord  A a aie a ei ae ed 41   6 5 6 Process    Calle dant Wes Aiea ee cat en aa nd 42   6 5 7 Block Write Read aaia ire ai tiad antenne nettement een anne 42   6 5 8 Block Write Block Read Process Call    43   6 5 9 SMBus Host Notify protocol    44   6510 Write  cepili Hassan etre ee AEEA A OEE E AROAN 45   6 5 11 R  ad 32 protocolo diri een lia 46   6 5 12 WEGE protocol    nent nu ere en es ciedad 46   6 5 13      Read G4 protoCl ne ne Mn nee rte ete detre siens AARAA 47   6 6 SMBus Address Resolution Protocol ss 48  6 6 1 Unique Device Identifier  UIDID     nara rarcc nn nrnnn nr 49   6 6 2 POWET   N TOS Mission A A A D 53   6 6 3 ARP COMMANS EE 53   Appendix A  Optional SMBUS Signals iii 72  A 1 TEE 72  A 2 INBA nette Una tnt nt ee EE 73  Appendix B  Differences between SMBUS and VC  75  B 1 Vo And Threshold Voltage Differences             s nssssnnessnnneeeennnsetrtsrttnnnsrtnnnnttnnnnttn rnnr nn nnen nn nennen 75   B 2 Minimum Bus Speed And Maximum Clock Stretching                                 75   B 3 Address  Acknowledg       lutin das 75   B 4 EE Oe Mee 76   B 5 REPEATED  START Conditi  ni ssfssiestirete derniers dA KENE Edel 76   B 6 SMBus Low Power Version    iii 76   B 7 Tables Of Diff  rences iima Wise ceca ele ade es D
44. are To ARP    command        2014 System Management Interface Forum  Inc  70 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    4  Ifthe ARP Master receives the    Notify ARP Master    command before it can  issue the    Prepare To ARP    command it will simply ignore it     5  The ARP Master will issue the    Get UDID    command since presumably the     Prepare To ARP    command was acknowledged     6  After detecting the repeat Start condition and receiving the SMBus Device  Default Address with the R W  bit set the devices will transmit the byte count for  this command without collision     7  The devices will begin to transmit the most significant byte of their UDID as  follows   Device A  0000 0001 0    Device B  1111 1110 1    Seen on the bus    O Device A wins the bus arbitration       Device A wins the bus arbitration since it is transmitting a    0    as the MSB in the  most significant byte of the UDID whereas Device B is transmitting    1     As such  Device B will cease transmission of this packet  Device A will complete its  transmission     8  The ARP Master will send the    Assign Address    command using Device A   s slave  address and UDID  Device A will then set its Address Resolved flag  the  Address Valid flag was already set   Device A will no longer respond to the    Get  UDID    command until it receives the    Prepare To ARP    or    Reset Device     commands or is power cycled     9  The ARP Master will add slave 
45. as issued  If so  then it proceeds to step 17  otherwise it proceeds  to step 19     17  Upon receipt of the    Assign Address    command the device must compare its  UDID to the one it is receiving  If any byte does not match then it must not  acknowledge that byte or subsequent ones  If all bytes in the UDID compare  then the device proceeds to step 18  otherwise it must return to step 7 and  wait for another SMBus packet     18  Since the UDID matched  the device must assume the received slave address and  update its PSA  if supported  The device must set its Address Valid and  Address Resolved flags that means it will no longer respond to the    Get  UDID    command unless it receives the    Prepare To ARP    or    Reset Device     commands or is power cycled  Proceed to step 7 and wait for another SMBus  packet     19  The device checks the command field to see if the    Get UDID    command was  issued  If so  then it proceeds to step 21  otherwise it proceeds to step 20     20  The device may be receiving a directed command  Directed commands must only  be acknowledged by slaves with a valid address  If the address is not valid  then ignore the packet and return to step 7 and wait for another SMBus  packet  If the address is valid then proceed to step 26     21  Upon receipt of the    Get UDID    command the device must check its Address  Resolved flag to determine whether or not it should participate in the ARP  process  If set then its address has already been resolve
46. aster may start a transfer only if the bus is idle  One or more devices may generate  a START condition within the minimum hold time  Thorn srta  resulting in a defined  START condition on the bus     Since the devices that generated the START condition may not be aware that  other masters are contending for the bus  arbitration takes place on the SMBDAT  line while the SMBCLK is HIGH  A master that transmits a HIGH level  while another  master  or masters  is transmitting a LOW level on the SMBDAT line loses control of  the bus in the arbitration cycle     The master that lost the arbitration may continue to provide clock pulses until the  completion of the byte on which it lost the arbitration  Arbitration in the case of two  masters trying to access the same device may continue past the address byte  In this  case arbitration will continue with the remaining transfer data  In the event that two  masters are arbitrating and the first master wants to put a repeated START on the bus  while the second master wants to put a ZERO data bit on the bus  the first master  must recognize that it cannot cause the start and lose arbitration  If the first master       2014 System Management Interface Forum  Inc  31 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    wants to put a repeated START on the bus while the second master wants to put a  ONE data bit on the bus  the second master will see the repeated start and lose  arbitration  H both maste
47. ata Byte 2  Bits  15 8   A  8 1 8 1    Data Byte 3  Bits  23 16   Data Byte 4  Bits  31 24   A  P      Figure 42  Write 32 Protocol       7 1 8 1  S Address Wr Command Code A  8 1 8 1  Data Byte 1  Bits  7 0   A Data Byte 2  Bits  15 8   EN  8 1 8    Data Byte 3  Bits  23 16   A Data Byte 4  Bits  31 24   A    eee       8 1  PEC Byte Ale          Figure 43  Write 32 Protocol With PEC       2014 System Management Interface Forum  Inc  45 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    6 5 11 Read 32 protocol    The Read 32 protocol is used with command  s that require reading up to 32 bits  4  bytes  of data from a slave device     This protocol can be used to read less than 32 bits but the packet must be padded to  fill 32 bits  Data or meaningful bits are packed into the lower order bits and unused  higher order bits are filled with zeros  For example  a 20 bit value is transmitted in bits   19 0  with the most significant bit in bit  19   Bits  31 20  are all zeros     7 1 1 8 1    S   Address  Wr A Command Code   A                   7 1 8 1    1  DEEE EU  8 1 8 1    Data Byte 2  Bits  15 8   A Data Byte 3  Bits  23 16   A BS    8    l  Data Byte 4  Bits  31 24     N   P      Figure 44  Read 32 Protocol             7 1 1 8 1  7 1 1 8 1  Sr Address RdJA  DataByte1 Bits 70   A         8 1 8 1  Data Byte 2  Bits  15 8   A   Data Byte 3  Bits  23 16   e  1    8 1 8  Data Byte 4  Bits  31 24   A PEC Byte NTP          Figure 45  Read 32 Pr
48. ation Working Group could ascertain no supplier of SMBus  devices or any system OEM using SMBus ever tested for compliance to this parameter  The  Working Group decided to drop this parameter from the Revision 3 0 specification     It was replaced by the  Fr parameter  Table 2  which is based on a similar specification in the  IC specification  This brings the SMBus PHY specification more into line with the 12C  specification simplifying design of the devices and systems     D 5 Zone Read And Write Protocols    The addresses reserved for the ZONE READ and ZONE WRITE protocols  introduced in  Revision 1 3 of the PMBus    specification   R06   were added  Section Table 17      D 6 255 Bytes in Process Call    The maximum number of bytes allowed in the Block Write Block Read Process Call  Section  6 5 8  was increased from 32 to 255     D 7 32 And 64 Bit Protocols    Protocols were added to read and write 32 and 64 bits of data in one transaction  Sections  6 5 10  6 5 11  6 5 12 and 6 5 13    D 8 Reformatting Of Text  Figures  And Tables    The document was reformatted to match the formatting used in the PMBus specifications  The  changes include reformatting of the text  redrawing and renumbering the figures  and  reformatting and renumbering the tables        2014 System Management Interface Forum  Inc  85 of 85  All Rights Reserved    
49. ation and may have  other meanings in other contexts  Some of these terms are used throughout the  specification while others have meaning only within limited portions        Term    Definition       Address Resolution  Protocol    A protocol by which SMBus devices with assignable addresses on  the bus are enumerated and assigned non conflicting slave  addresses        Address Resolved flag  AR     A flag bit or state internal to a device that indicates whether or not  the device s slave address has been resolved by the ARP Master        Address Valid flag  AV     A flag bit or state internal to a device that indicates whether or not  the device s slave address is valid  This bit must be non volatile for  devices that support the Persistent Slave Address        Alert Response Address   ARA     A broadcast address used by the system host as part of the Alert  Response Protocol initiated when a device asserts the  SMBALERT  signal        ARP    Address Resolution Protocol       SMBus ARP Enumerator    A SMBus master that uses a subset of the ARP for the purpose of  discovering ARP capable slave devices and their assigned slave  addresses        ARP Master    The SMBus master  hardware  software or a combination   responsible for executing the ARP and assigning addresses to  ARP capable slave devices  The SMBus Host will usually be the  ARP Master but under some circumstances another SMBus  master may assume the role  There is only one active ARP Master  at any time        Assig
50. ble 12  Device decodes of AV and AR flaQS cnc rana rn 66  Table 13  SMBus Suspend parameters sisi 72  Table 14  Selected parameter differences between Standard Mode I C and 100 kHz Class SMBus         76  Table 15  DC parameter differences between Fast mode PC and 400 kHz Class CM    us 77  Table 16  DC parameter differences between Fast mode Plus BC and 1 MHz Class SMBus             78  Table 17  Reserved and pre assigned SMBUS Addresses    cocooocconoccconococonccononanonancnano corn cnn non n naar nana tennene nnn 81    Table of Figures    Figure 1  Generic transaction dagram  nenn nent 14  Figure  2  SMBUS  TOPOl09Y  ctra rl dida 15  Figure 3  SMBus pull up circuitry sise 15  Figure 4  Example input and output stages of SMBUS devices   ooooonccccincccnoccconocanonoccnancccnnnca nar nnnann cnn rca 16  Figure 5  SMBus timing measuremente iii 18  Figure 6 lt  NmMeout miery le  ere seat items E nantes rente nca eas ee ane ot educates lie cae ens 2e NEED te 21  Figure 7  Clock extension measurement intervals ss 22  Figure 8  SMBus branch with multiple devices attached nent 23  Figure 9  SMBus circuit model iii 24  Figure  110  Data Validity A A A ee eme es ee eE 28  Figure  11  START and S TOP CONOIIONS simios loja rada 28  Figure 12  SMBus  byte format  id E 29  Figure 13  ACK signaling Of SMBUS                                     iii 29  Figure 14  NACK signaling on SMBUS iii 30  Figure 15  SMBus clock synchronization sis 31  Figure 16  SMBUS arbitration iii 32  Figure 17  P
51. ces and includes tables that provide a summary of the key  differences     B 1 Vo And Threshold Voltage Differences    The I C specification  R01  gives minimum or maximum values for the supply voltage  Vos  of  devices attached to an I C bus  In one section it even discusses devices with supply voltages of  12 V  In contrast  SMBus V3 0 restricts the nominal supply voltages of devices attached to a  SMBus to a minimum of 1 8 V and a maximum of 5 V  Section 4 3 4      The I2C and SMBus specifications also specify the logic input threshold voltages  Vu and Vu   differently  The 12C specification requires that Vu be 30  of Vpp and that Vu be 70  of Vpp  The  SMBus V3 0 specification has fixed thresholds  Vu is set to 0 8 V and Vy is set to 1 35 V   Section 4 3 4      There are also differences in the low output voltage and current specifications  These  differences are summarized in the tables below  The biggest difference is for the specifications  for operation at 400 kHz  For operation at 400 kHz a pull up current of at least 6 mA is needed  to guarantee the rise time will meet specification in the worst case  lowest Vpp  highest bus  capacitance  highest leakage current   The EC specification allows the clock and data outputs to  rise to 0 6 V while sinking 6 mA  This reduces the noise significantly and even to a negative  value  With a Vs of 1 8 V and Vu equal to 30  of Vpp the maximum Vu will be 0 54 V  which is  less than the 0 6 V output low voltage     To assure operat
52. d by the ARP Master  so the device proceeds to step 7 to wait for another SMBus packet  If the AR  flag is cleared then the device proceeds to step 22     22  The device returns its UDID and monitors the SMBus data line for collisions   If a collision is detected at any time the device must stop transmitting and  proceed to step 7 and wait for another SMBus packet  If no collisions were  detected then proceed to step 23     23  The device must now check its Address Valid flag to determine what value to  return for the Device Slave Address field  If the AV flag is set then it proceeds  to step 24  otherwise it proceeds to step 25     24  The current slave address is valid so the device returns this for the Device  Slave Address field  with bit O set  and monitors the SMBus data line for  collisions  i e  another device driving a    0    when this device is    driving    a    1      Proceed to step 7 and wait for another SMBus packet     25  The current slave address is invalid so the device returns a value of FFh and  monitors the SMBus data line for collisions  If the ARP Master receives the  FFh value it will know that the device requires address assignment  Proceed to  step 7 and wait for another SMBus packet     26  Is this a directed    Reset Device    command  If so then proceed to step 15   Otherwise proceed to step       2014 System Management Interface Forum  Inc  65 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    27  Is this t
53. ddress Pool  Initially this  will consist of the slave addresses of fixed SMBus devices known to the ARP  Master and reserved addresses  as defined in Appendix C      Send the    Prepare To ARP    command     Check for an acknowledgement for all bytes in the previous packet  If any  bytes were not acknowledged then the ARP Master can assume that no  ARP capable devices are present and may therefore consider the ARP process  complete and proceed to step 4  If all bytes were acknowledged then go to step  6       The ARP Master found no response to the    Prepare To ARP    command so it can    assume that no ARP capable devices are present in the system at this time   The ARP Master may periodically re issue the    Prepare To ARP    command  to discover any ARP capable devices added  Proceed to step 5     Wait for a SMBus packet  If a packet is received proceed to step 15   Send the    Get UDID    command     Check for an acknowledgement for the first three bytes and verify that the   byte count value received is 11h  If not  then the ARP Master can assume that  an ARP capable device s  is no longer present and may therefore consider the  ARP process complete and Proceed to step 4  Otherwise proceed to step 8     Check the value of the Device Slave Address received  If FFh then proceed  to step 11 since this device does not possess a valid slave address   Otherwise proceed to step 9     Determine if this device has a fixed slave address  If bits 127 and 126 of the  UDID are 00b 
54. dress  When  this happens  the device must issue a host notify protocol if the device supports  it                                      6 6 2 Power on reset  Power on reset is described in section 4 3 5 2  In the case of ARP capable  devices     operational state    implies the ability to respond to ARP commands as  required in this section   Each slave device must fit into only one of these categories and must obey the  power on reset state   Table 9  Internal state of ARP capable devices on Power On Reset  Device Type AR Flag  AV Flag  SMB Address  UDID  PSA CLEAR Read from   Read from NVR   NO CHANGE   Persistent Slave Address  NVR undefined if AV  Flag is CLEAR  Noir PSA NOR Random CLEAR  CLEAR  undefined NO CHANGE  Number  Non PSA   Random Number  CLEAR CLEAR undefined Generate  Random Number  6 6 3 ARP commands  The ARP Master can issue general commands and directed commands  A general  command is targeted at all devices and is required for the address resolution  process  A directed command is targeted at a single device  All packets originated  by the ARP Master use Packet Error Checking  See Section 6 4  and begin with  the basic format    lt SMBus Device Default Address gt   lt command gt      2014 System Management Interface Forum  Inc  53 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Table 10  ARP command number scheme        lt SMBus Device Default 1100 001b  the R W  bit completes the byte   Address gt  lt command gt 
55. e   1000   300   120 ns  See Note 7   tsPIKE Noise spike suppression time     0 50 0 50 ns  See Note 8   tpor Time in which a device must be operational after 500 500 500 ms  See Section 4 3 5 2   power on reset                                     Note 1  The minimum frequency for synchronizing device clocks is defined in Section 5 3 3  A master shall not drive the clock  at a frequency below the minimum fav  Further  the operating clock frequency shall not be reduced below the minimum value of  fsmp due to periodic clock extending by slave devices as defined in Section 5 3 3  This limit does not apply to the bus idle condition   and this limit is independent from the ttow  sext and tLow  mexrt limits     For example  if the SMBCLK is high for then max  the clock must not be periodically stretched longer than 1 fsus min     Tou Max   This requirement does not pertain to a device that extends the SMBCLK low for data processing of a received byte  data buffering  and so forth for longer than 100 us in a non periodic way     Note 2  A device must internally provide sufficient hold time for the SMBDAT signal  with respect to the Vu wm of the SMBCLK  signal  to bridge the undefined region of the falling edge of SMBCLK     Note 3  Devices participating in a transfer can abort the transfer in progress and release the bus when any single clock low interval  exceeds the value of trmeour min  After the master in a transaction detects this condition  it must generate a stop condition wi
56. e   many specific items  including general ac specifications  are the same in both  environments                          O  Input A  Stage K  Pin Pin    H D     IN  O  Output A  L     Stage l  pa  ri    Pin Pin  Devices A will pull the bus down to 0 6 V These devices will allow the bus to float  when powered down  when powered down        Figure 4  Example input and output stages of SMBus devices    A Low Power and a High Power bus may not be directly connected to each other  Low   power devices should not be expected to work on a High Power bus if the device   s  current sink capability is smaller than 4 mA  However  it is possible to combine a  Low Power bus segment and a High Power bus segment by connecting the two bus  segments through a suitable bridge device     4 2 SMBus Common AC specifications    Both the High Power and Low Power SMBus electrical interface share a common  set of ac specifications  Figure 5 illustrates the various SMBus timings and sets the  context for the specifications to follow        2014 System Management Interface Forum  Inc  16 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    SMBus devices may support one of three different maximum bus speeds  100 kHz   400 kHz  and 1 MHz  The timing characteristics for each of these maximum bus  speeds are given in Table 2        2014 System Management Interface Forum  Inc  17 of 85  All Rights Reserved    SMBCLK  Vu    SMBDAT       System Management Bus  SMBus  Specif
57. e Interface Protocols  supported     The most significant bits of the Interface field are used to identify the protocols  supported by the device  The least significant nibble is used to identify the  SMBus version     Supported Protocols SMBus Version  Bits  15 4  Bits  3 0     MSB LSB       Figure 53  Interface field  Table 8  Interface field bit fields description                Bit s   Field Description    15 8  Reserved Reserved for future definition under the SMBus specifications   7  ZONE Device supports ZONE WRITE and ZONE READ protocols   6  IPMI Device supports additional interface access and capabilities    per IPMI specifications     5  ASF Device supports additional interface access and capabilities  per ASF specifications        4  OEM Device supports vendor specific access and capabilities per the  Subsystem Vendor ID and Subsystem Device ID fields returned  by discoverable SMBus devices     The Subsystem Vendor ID identifies the vendor or defining body  that has specified the behavior of the device  The Subsystem  Device ID is used in conjunction with the System Vendor ID to  specify a particular level of functional equivalence for the  device                    O 2014 System Management Interface Forum  Inc  51 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    6 6 1 4    6 6 1 5    6 6 1 6       Bit s   Field Description        3 0  SMBus Version These bits define the SMBus version as defined here        0000b SMBus 1 0  
58. e Pnau ar EEN dues 76  Appendix C  SMBus Device Address Assignments    oooonncccnnccccocccononanonancnonccnonn cnn arc nnnn cnn rca nn cnn nn 81  Appendix D  Changes This Revision sisi 83  D 1 Maximum Bus Frequency    sise 83   D 2 Fl  ctrical Drive  Levels  animon   t sti 83   D 3 Data Hold RE 83   D 4 TspPikE In Place Of VhnoIse A A A a M Se eee RSENS Ne KEE 85   D 5 Zone Read And Write Protocols                                                cnn naar cnn nn nn 85   D 6 255 Bytes  in  Process Callas ta e EE AEN EE 85   D 7 32 And 64 Bit Protocols ege ir di td au a de bt hb 85   D 8 Reformatting Of Text  Figures  And Tables    85   O 2014 System Management Interface Forum  Inc  4 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Table of Tables    Table 1  Transaction protocol diagram symbols and elements AA 12  Table 2  SMBus AC Specifications si 18  Table 3  Low Power SMBus DC specification                                    nora nn cnn rana cnn 24  Table 4  High Power SMBus DC specification                                                     crac rra 26  Table 5  UDID bit fields descriptions ss 49  Table 6  8 bit device capabilities field descriptions    50  Table 7  Version Revision bit fields description    50  Table 8  Interface field bit fields description    51  Table 9  Internal state of ARP capable devices on Power On Reset    53  Table 10  ARP command number scheme sise 54  Table 11  SMBus device charactertzaitons ss 54  Ta
59. e that all devices will share a common Von  hence fixed voltage  logic levels     4 3 4 High Power DC specifications    The electrical specifications for High Power SMBus are given in Table 4  These  higher power specifications provide the robustness necessary  for example  to  allow SMBus to cross the PCI connector  thus allowing SMBus devices on PCI  add in cards to communicate with other devices on both the system board and other  PCI add in cards in the same system  These higher power electrical specifications  are an alternative to the lower power specifications stated above and may be used  in environments where necessary  Some parameters are explained further in the  sections below     O 2014 System Management Interface Forum  Inc  25 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Table 4  High Power SMBus DC specification                                                                         100 kHz 400 kHz 1 MHz  Symbol Parameters Class Class Class Units   Comments  Min Max  Min Max  Mm Max   Voo Nominal Bus Voltage 1 8 5 1 8 5 1 8 5 V   Operating Bus Voltage 1 62 5 5 1 62 5 5 1 62 5 5 V   Nominal   10   Vi Low level Input Voltage   0 8   0 8   0 8 V  Vin High level Input Voltage 1 35 Voo 1 35 Voo 1 35 Voo V  Vays Hysteresis voltage of Schmitt trigger inputs 80   80 S 80   mV  Vol Low level Output Voltage S 0 4   S     NV lo   4mA    See Section 4 3 4 2      E 04 S bL  6 mA   S         0 4 lo   20 mA  ILEAK BUS Input Leakage
60. ents that can be hot plugged to the  system  such as a Smart Battery  The Equivalent Series Resistor  ESR  of the  device and interconnect must not exceed 1 1 KQ in order to maintain the Vo  max of  the SMBus Low Power specification  This circuit model is equally valid for High Power  components discussed in Section 4 3 4  Due to significantly different bus loading   individual component values will change     O 2014 System Management Interface Forum  Inc  23 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0         Interconnect i SMBus i  Rs2 Device  e g   Selector       Optional    Protection    CR E O RE AAA AA    Figure 9  SMBus circuit model    The value of the pull up resistors  Rp  will vary depending on the system s Von  and the bus    actual capacitance  Current sources  Ip  offer better performance but  with increased cost     The optional diode shown in the diagram above is for ESD protection  lt may be  necessary in systems where a removable SMBus device such as a Smart Battery is  used  However  circuits as actually implemented must comply with the previously  stated unpowered leakage current specification     4 3 3 Low Power DC parameters    Table 3  Low Power SMBus DC specification                                           Limits  Symbol Parameter S Units  Comments  Min Max  Von Nominal bus voltage 1 8 5 0 V  Operating bus voltage 1 62 5 5 V   Nominal  10   Vin HIGH level input voltage for 1 35 Voo V  SMBCLK and SMBDAT  Vu LO
61. eriodic clock stretching by a Slave SMBUS device    33  Figure 18  Random clock stretching                                        ss 34  Figure 19  Data transfer over SMBUS iii 34  Figure 20  Quick  Command protocol sz    sccicyscthescecceataseetebvnacchenns ij dai 39  Figure 2 1 Send  Byte re ee 40  Figure 22  Send Byte protocol with DE    40  Figure 23  Receive Byte protocol sisi 40     2014 System Management Interface Forum  Inc  5 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Figure 24  Receive Byte protocol with D    40  Figur   25 Write Byt   protocol  tt ted 40  Figure 26  Write Word ere ee E 40  Figure 27  Write Byte protocol with PEC iii 41  Figure 28  Write Word protocol with PEC iii 41  Figure 29  Read Byte protocol    iii 41  Figure 30  Read Byte protocol with PEC sise 41  Figure 31  Read Word protocol    issues 41  Figure 32  Read Word protocol with DEL 42  Figure  337 Process Galli iaa 42  Figure 34  Process Call with DEL iii 42  Foure 307 Block Writer fat A ian hia eda a ha es 43  Figure 36  Block Write with PE    43  Figure RE ee ii A A Ad te ett 43  Figure 38  Block Read with PEC iii 43  Figure 39  Block Write   Block Read Process Call    ss 44  Figure 40  Block Write   Block Read Process Call with PEC ss 44  Figure 41  7 bit Addressable Device to Host Communication              ceceeeeeteeeeeeeeeeeeteeeeeseeeeeaeeteneeeeaes 45  Figure 42  Write 32 Protool inei ina aaa ea 45  Figure 43  Write 32 Protocol With DE 45
62. ersion    For applications where power usage must be minimized  such as in battery operated systems   the SMBus specification has a Low Power class  Section 4 3 3   EC does not have a similar  specification     B 7 Tables Of Differences    The following tables summarize key differences in the 12C and High Power SMBus  specifications  These tables are offered as a convenient reference but do not include every  parameter that might be of interest  System engineers intending to operate IPC and SMBus  devices on the same physical bus are encouraged to compare the SMBus and EC  specifications in detail     Table 14  Selected parameter differences between  Standard Mode PC and 100 kHz Class SMBus                                                          Std PC mode 100 kHz Class  Symbol   Parameter device SMBus device   Units  Comments  Min Max Min Max  Von Nominal bus voltage         1 8 5 0 V  Operating bus voltage         1 62 5 5 V   Nominal  10   Vit LOW level input       0 8 V   Fixed input level  valtage  0 5 love  2   V     Vpp related input  level  Vin HIGH level input         1 35 Vop V Fixed input level  voltage    0 7 Vpp   Note 1         V_  Voo related input  level  Vuys Hysteresis voltage of         0 08     V  Schmitt trigger inputs     2014 System Management Interface Forum  Inc  76 of 85    All Rights Reserved       System Management Bus  SMBus  Specification Version 3 0                                                                                                
63. evice or as a slave device     There may be more than one master on a SMBus   6 1 2 Slave devices    A slave device responds to its own address and receives commands  Depending on  the transaction type  a slave may either receive data from a master device  slave   receiver  or may send data to a master device  slave transmitter      A device may be designed to be a slave only  A slave device may also be  designed to become a master in certain circumstances  such as when using the  Host Notify protocol  Section 6 5 9      The number of slaves in a system is theoretically limited only by the number of  available addresses  In practice  the number of slaves is limited by the maximum  bus capacitance and rise time specifications     6 1 3 Host    A host is a specialized master that provides the main interface to the system s CPU or  system management processor     host must be a master slave and must support the  SMBus Host Notify protocol  Section 6 5 9      A system does not need to have a host  One example of a hostless system is a simple  battery charging station  The station might sit plugged into a wall waiting to charge a  smart battery     There may be at most one host in a system     6 2 Device Identification     Slave Address  6 2 1 Uniqueness required    Any device that exists on the System Management Bus as a slave has a unique  address called the Slave Address     6 2 2 SMBus address types    Several SMBus devices can be used simultaneously in an actual system  In ca
64. g the SMBus Device  Default Address with the R W  bit set the devices will transmit the byte count  for this command without collision  The devices will then begin to transmit their  UDIDs as follows        2014 System Management Interface Forum  Inc  68 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Device A  1000     Device B  1111     Device C  1111       Seen on the bus        1 0  1 1  1 1  1 0 Device A wins the bus arbitration    Device A wins the bus arbitration since it is transmitting a    0    as the 2  MSB in  the most significant byte of the UDID whereas Devices B  amp  C are transmitting    1      As such Devices B  amp  C will cease transmission of this packet  Device A will  complete its transmission    1  The ARP Master will send the    Assign Address    command using Device A s slave  address and UDID  Device A will then set its Address Resolved flag  the  Address Valid flag was already set   Device A will no longer respond to the    Get  UDID    command until it receives the    Prepare To ARP    or    Reset Device     commands or is power cycled     2  The ARP Master will add slave address 1001 001 to the Used Address Pool  since Device A acknowledged the packet     3  The ARP Master will issue the    Get UDID    command again     4  Devices B  amp  C having lost the previous arbitration will respond and will  transmit the byte count for this command without collision     5  The devices will begin to transmit their U
65. h the alerting device s address  This protocol          2014 System Management Interface Forum  Inc  44 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    MUST be used when a SMBus device becomes a master in order to communicate  with the SMBus host acting as a slave     Communication from a SMBus Device to the SMBus Host begins with the SMBus Host  address  0001 000b   The message s Command Code is the initiating SMBus  device s address  From this  the SMBus Host knows the origin of the following 16  bits of device status  The contents of the status are device specific    7 1 1 7    S SMB Host Address Wr A Device Address X MA       8 1 8 1  Data Byte Low Data Byte High  A        Figure 41  7 bit Addressable Device to Host Communication    SMBus hosts must support the host notify protocol  Hosts may implement the  optional SMBALERT  line if devices in the system use it     6 5 10 Write 32 protocol    The Write 32 protocol is used with commands that require sending to a slave device  up to 32 bits  4 bytes  of data     This protocol can be used to send less than 32 bits but the packet must be padded to  fill 32 bits  Data or meaningful bits are packed into the lower order bits and unused  higher order bits are filled with zeros  For example  a 20 bit value is transmitted in bits   19 0  with the most significant bit in bit  19   Bits  31 20  are all zeros           7 1 8 1  S Address Wr Command Code A  8 1 8 1  Data Byte 1  Bits  7 0   A D
66. he    Directed Get UDID    command  If so  then proceed to step 29   Return the UDID information  If not  then proceed to step 28    28  The device has not received a valid command so it must handle the illegal  command in accordance with SMBus rules for error handling  Proceed to 7 and  wait for another SMBus packet     29  Return the UDID information and current slave address  then proceed to 7  and wait for another SMBus packet     The flow diagram does not cover consideration for bus timeout mechanisms   These should be implemented in order to comply with the bus timing  specifications  If the device supports the    Notify ARP Master    command it may  wish to consider implementing a timeout mechanism  This mechanism could  cause the device to re issue the    Notify ARP Master    command if the ARP  Master doesn t respond within a particular time period     The device decodes the two internal flags as described in the following table   Table 12  Device decodes of AV and AR flags    Address Valid Address Resolved   AV Flag   AR Flag     Cleared The device does not have a valid slave address and  will participate in the ARP process  This is the POR  state for a device that doesn t support the PSA or if it  does it has not previously been assigned a slave  address     Meaning       Illegal state     The device has a valid slave address but must still  participate in the ARP process        The device has a valid slave address that has been  resolved by the ARP Master  The dev
67. he first two bits presented when a  device presents its UDID  all fixed address devices on the bus are detected  during ARP first  followed by devices with dynamic and persistent addresses  and  so on  The bits in the brackets below show the highest two bits  the address type  field  within the Device Capabilities field     00  Fixed Address devices are identified first     01  Dynamic and Persistent Address devices are identified next    10  Dynamic and Volatile Address devices are identified next    11  Random Number devices are identified last        Bits  7 6  Bit  5  Bit  4  Bit  3  Bit  2  Bit  1  Bit  0     Address Type Reserved   Reserved   Reserved   Reserved   Reserved PEC       0   0   0   0   0    Supported  MSB LSB    Figure 51  8 bit device capabilities field  Table 6  8 bit device capabilities field descriptions          Bit s    Field Description   7 6  Address Type These two bits describe the type of address contained in the  device     00b Fixed Address device   01b Dynamic and persistent address device  10b Dynamic and volatile address device  11b Random number device        5 1  Reserved Reserved bits are for future extendibility and must be returned  as Ob and ignored when read         0  PEC Supported This bit is set if the device supports Packet Error Code on all  commands supported at the device s SMBus address  associated with this UDID  If this bit is not set  the ability of the  device to support PEC is unknown                 6 6 1 2 Version Revisi
68. hite  Embedded Power Labs                               Questions and comments regarding this For additional information on Smart Battery System  specification may be forwarded to  Specifications  visit the SBS Implementer   s Forum  techquestions smiforum org  SBS IF  at    www sbs forum org     2014 System Management Interface Forum  Inc  2 of 85    All Rights Reserved       System Management Bus  SMBus  Specification Version 3 0    Table of Contents    ITFOCUCUON osito ll tia 8  1 1 OVErvieW A sa deus sada A AA A dra  8  1 2 te Le 8  1 3 SCODC  end dees Tee A Ie anes eel SEENEN  8  1 4 Organization of this document    sisi 8  Related Documents And Reference Information    9  2 1 SCOPE m nn TEE 9  2 2 eet Le ele IEN 9  2 3 Reference Documents  9  2 4 D  finitions OF  TERMS aaa ed 10  2 5 Conventions  it A A detre E 11  2 5 1 NUM ETICO MAS EE  AS 11   2 5 2 SMBus address  s cio ida A Re a Dota des 12   2 5 3 Transaction protocol dagrams nanten 12  General Characteristics de nn croate a a dou   14  Layer 1     The Physical Layer    sieste 15  4 1 Electrical Characteristics Of SMBus Devices     Two Discrete Worlds         15  4 2 SMBus Common AC specifications                                        rra 16  4 2 1 General timing Condittons nt 21   4 2 2 Device timeout definitions and conditions    21   4 2 3 Master device clock extension definitions and conditions    21   4 2 4 Slave device clock extension        occccccccconocccccncncnnnnnnacncnnnnn nono nonnnn nn nano nononna 
69. hout a PEC   verify the correctness of the PEC if present  and only process the message if the  PEC is correct  Implementations are encouraged to issue a NACK if the PEC is  present but not correct     ACK NACK and Packet Error Checking    The ACK NACK bit in a SMBus byte is as susceptible to corruption as any other bit in  a SMBus packet  Hence  an ACK at the end of a PEC is not a guarantee that the  PEC is correct  A master transmitter receiving an ACK at the end of a write  should not necessarily assume that the write was successfully carried out at the  slave receiver of the write  although it is highly likely that it was     A NACK received after a PEC by a master transmitter indicates that the link layer  of the slave receiver became aware of an error with the transmission in time to  supply a NACK at the end of the PEC byte  This may be due to an incorrect PEC  or any other error  Errors discovered above the data link layer may also be indicated  with a NACK if the device is fast enough to discover and indicate the error when  the NACK is due     O 2014 System Management Interface Forum  Inc  37 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    6 4 1 2    6 4 1 3    An ACK received after a PEC by a master transmitter means that no error could  be determined by the link layer in the slave receiver in time to supply a NACK   This might be because the receiver is not able to check the validity of the PEC in  real time     If a master
70. ication Version 3 0           Jop era             Figure 5  SMBus timing measurements  Table 2  SMBus AC specifications                                                                               100 kHz 400 kHz 1 MHz  Symbol Parameters Class Class Class Units   Comments  Min Max   Min Max   Min Max  foe SMBus Operating Frequency 10 100 10 400 10 1000 KHz   See Note 1  tur Bus free time between STOP and START Condition   4 7   1 3   0 5   us  tHD STA Hold time after  REPEATED  START Condition 4 0   0 6   0 26   us   After this period  the first clock is  generated  tsu sTA REPEATED START Condition setup time 4 7   0 6   0 26   us  tsu sTo STOP Condition setup time 4 0   0 6   0 26   us  tHD DAT Data hold time 0   0   0   ns   See Note 2  tsu DAT Data setup time 250   100   50   ns  trimeouT Detect clock low timeout 25 35 25 35 25 35 ms   See Note 3  tow Clock low period 47   13   0 5   US  tHicH Clock high period 40 50 0 6 50 0 26 50 us  See Note 4  tlow Sext Cumulative clock low extend time  slave device    25   25   25 ms  See Note 5     2014 System Management Interface Forum  Inc  18 of 85    All Rights Reserved       System Management Bus  SMBus  Specification Version 3 0                         100 kHz 400 kHz 1 MHz  Symbol Parameters Class Class Class Units  Comments  Min Max   Min Max   Min Max     LOW MEXT Cumulative clock low extend time  master device    10   10   10 ms  See Note 6   tr Clock Data Fall Time   300   300   120 ns  See Note 7   tr Clock Data Rise Tim
71. ice will not  respond to the    General Get UDID    command   However  it could subsequently receive an     Assign Address    command and would change its  slave address accordingly                 2014 System Management Interface Forum  Inc  66 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0       Power On  Reset    Persistent  Slave Address  Supported                  Clear The  Address Resolved  And Address Valid  Flags                    Persistent  Slave Address  Supported     No       Clear The  Address Resolved  Flag       Set The  Slave Address To PSA  And Clear The  Address Resolved Flag            Optional  Send  l    Notify ARP Master       Command I                                                                                                                                                                                                       NS    Is The No    Slave Address Field  Address Valid Matches The SMBus  Flag Set  ARP Address   Yes  Yes  No 10 Slave Address Field  Matches The Device s d 13 ACK Packet  Slave Address  Prepare To es And Clear The  ARP Command  Address Resolved  Flag  Yes  11  Process Access To No  Device Function  15 ACK Packet  k 14 General Yes And Clear The  Reset Device Address Resolved  Command  And Address Resolved  Flags  If non PSA   No  Assign Yes 17 No  Address  Command   No Yes  ACK Packet   18 Set Slave Address And  20 19  No Se GE lid No eons Persistent Slave Address To The  Ger Ka c z d  A
72. ified  These  bits and fields are reserved for future use and may not be used by  OEMs or IHVs     REPEATED START A REPEATED START is a START condition on the SMBus used  to switch from write mode to read mode in a combined format  protocol  e g  Byte Read   The repeated START always follows an  Acknowledge  and it always indicates that an address phase is  beginning           Self powered device A self powered device is a device powered either by a battery or  an external power source  but not by the system of which it is a  part and not in any way by the SMBus        Slave  Slave receiver  See Section 6 1 2   Slave transmitter       SMBALERT  An optional signal that a slave device can use to notify the system  master that it has information for the master       START The condition a master uses to signal the devices on the SMBus  that a transaction is beginning  A START condition is generated  by the master by driving SMBDAT low while SMBCLK is high    STOP The condition a master uses to signal the devices on the SMBus  that a transaction is ending  A START condition is generated by  the master by allowing SMBDAT to go high while SMBCLK is  already high          Used Address Pool The list of slave addresses known by the ARP Master that are  either     e Reserved   e Used by non ARP capable devices  Fixed Slave  Addresses    e Already assigned to ARP capable devices    The ARP Master must not assign addresses from the first two  categories to ARP capable devices             
73. ing    general purpose UO pins of a microcontroller  The disadvantage is that  it is not possible to simply verify that the receiving device is properly seeing the data line remain  stable until the clock is low     This difference in how the data hold is specified has been the biggest difference in the timing  specifications of the SMBus and BC specifications  The reality has been that most devices on  the market  even those that claim to be SMBus compatible  have really managed the data hold  time in accordance with the 1 C specifications     O 2014 System Management Interface Forum  Inc  84 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    The PMBus SMBus Specification Working Group recognized this reality and decided to change  the SMBus data hold time specification to match the 12C bus  The SMBus data hold time  specification is now 0 ns with a note that the device receiving data is responsible for adding  whatever hold or delay is needed to assure that SMBDAT is not seen as changing before the  SMBCLK is low  This is a notable change and all users of the SMBus and PMBus need to take  note of this update their system requirements and system validations procedures accordingly     DA  Tsprike In Place Of Vnoise    In Revision 2 0 of the SMBus specification  the High Power DC Specifications  Table 3  included  the parameter Vyoise which described a minimum immunity to noise on the clock and data lines   As best the PMBus SMBus Specific
74. ion at 400 kHz without degrading the noise margin  the SMBus specification  requires that the output low voltage be 400 mV or less when sinking 6 mA     In general  even with the different specifications for the input logic voltage thresholds  1C and  SMBus devices will be interoperable over the supply voltages permitted by the SMBus  specification     B 2 Minimum Bus Speed And Maximum Clock Stretching    The EC bus specification does not give a minimum clock frequency  The master may hold the  clock line low forever and that would be a valid condition on and PC bus  In addition  the IC  specification permits a slave device to hold the clock line low for an unlimited amount of time     The SMBus specification does require a minimum operating frequency of 10 kHz  Table 2      In addition to the minimum bus operating frequency  the SMBus specification also places limits  on the maximum about of time a master may extend the clock low time within each byte of a  message  tLow mexr   There is also a limit on the total time a slave device may extend the clock  low time within each message  tLow sext      A further SMBus restriction on the bus operation is a timeout  trmeour  after which the bus is  presumed hung and all devices attached to the bus must reset their I O interface and make  ready to receive a START condition  Section 4 2 2      B 3 Address Acknowledge    The IC specifications do not require that a device always acknowledge its own address  This  can confuse a system c
75. ion to this rule  detailed later  is during initial bus setup when a single master may  initiate transactions with multiple slaves simultaneously  Another exception is during a  ZONE WRITE when a master may be sending data to multiple slaves simultaneously  A  bus slave device can receive data provided by the master or it can provide data to the  master     Only one device may master the bus at any time  Since more than one device may  attempt to take control of the bus as a master  SMBus provides an arbitration  mechanism that relies on the wired AND connection of all SMBus device interfaces to  the SMBus     This specification defines two classes of electrical characteristics  Low Power and  High Power  The first class  originally defined in the SMBus 1 0 and 1 1 specifications   was designed primarily with Smart Batteries in mind  but could be used with other Low  Power devices  Version 2 0 of the specification introduced an alternative higher power  set of electrical characteristics  This class is appropriate for use when higher drive  capability is required  for example with SMBus devices on PCI add in cards and for  connecting such cards across the PCI connector between each other and to SMBus  devices on the system board     This version  Version 3 0  of the SMBus specification introduces operation at higher  bus speeds  400 kHz and 1 MHz  and adds new data protocols for reading or writing  32 bit and 64 bit values  This version also reduces the minimum nominal Vpp fro
76. ive        2014 System Management Interface Forum  Inc  27 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    5  Layer 2     The Data Link Layer    5 1 Bit Transfers    SMBus uses fixed voltage levels to define the logic    ZERO    and logic    ONE    on the  bus respectively     5 1 1 Data validity    Data Line  Data Line Must May Only  Remain Stable Change  During This Interval When The  For The Data Clock Line  To Be Valid   Is Low      SMBCLK    Figure 10  Data validity    The data on SMBDAT must be stable during the high period of the clock  Data can  change state only when SMBCLK is low  Figure 10 illustrates the relationships  See  Figure 5 and Table 2 for actual specifications     5 1 2 START and STOP conditions       SMBCLK    SMBDAT       START Condition STOP Condition    Data Line Falling  Data Line Rising   While Clock Line While Clock Line  Is High  Is High     Figure 11  START and STOP conditions    Two unique bus situations define a message START and STOP condition    1  A HIGH to LOW transition of the SMBDAT line while SMBCLK is HIGH  indicates a message START condition    2  ALOW to HIGH transition of the SMBDAT line while SMBCLK is HIGH defines a  message STOP condition  START and STOP conditions are always generated  by the bus master  After a START condition the bus is considered to be busy  The       2014 System Management Interface Forum  Inc  28 of 85  All Rights Reserved    System Management Bus  SMBus  Specificati
77. k extension from a slave device or another master     A Master is allowed to abort the transaction in progress to any slave that violates the  tLow sexr Of tnmeour mn Specifications  This can be accomplished by the Master issuing a  STOP condition at the conclusion of the byte transfer in progress     A Master should take care when evaluating tLow sexr Violation during arbitration since  the clock may be held low by multiple slave devices simultaneously  The arbitration  interval may be extended for several bytes in the case of devices that respond to    O 2014 System Management Interface Forum  Inc  21 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    commands to the SMBus ARP address  If timeouts are handled at the driver level  the  software may need to allow timeouts to be configured or disabled by applications that  use the driver in order to support older devices that do not fully meet the SMBus  timeout specifications  Devices that implement    shared    slave addresses may also  violate this specification due to combined clock stretching by the different devices  sharing the address  The interval trmeour mn  however  does not increase due to  combined clock stretching  Therefore  this is a safer timeout parameter for a Master to  use when it knows it is accessing SMBus 2 0 or later devices     START CLKack CLKack STOP      TLow sexT       LOW MEXT   tLow mexT    Lowmexr           SMBCLK      4  Jot laf  al dst lol 171 ds  lol la 
78. lative to other data     SMBCLK  From  Master             Transmitter  Data  Output    Receiver  Data  Output       START ACK  SMBDAT Pulled Low    Condition During The Ninth Clock Pulse  Figure 13  ACK signaling of SMBus  O 2014 System Management Interface Forum  Inc  29 of 85    All Rights Reserved    SMBCLK  From  Master    System Management Bus  SMBus  Specification Version 3 0             Transmitter     Data i  Output    Receiver i  Data i  Output i  S    NACK  START NACK  SMBDAT Is High During  Condition The Ninth Clock Pulse    Figure 14  NACK signaling on SMBus    The acknowledge related clock pulse is generated by the master  The transmitter   master or slave  releases the SMBDAT line  HIGH  during the acknowledge clock  cycle  In order to acknowledge a byte  the receiver must pull the SMBDAT line LOW  during the HIGH period of the clock pulse according to the SMBus timing  specifications  A receiver that wishes to NACK a byte must let the SMBDAT line remain  HIGH during the acknowledge clock pulse     A SMBus device must always acknowledge  ACK  its own address  SMBus uses  this signaling to detect the presence of detachable devices on the bus     A SMBus slave device may decide to NACK a byte other than the address byte in the  following situations     e The slave device is busy performing a real time task  or data requested are not  available  The master upon detection of the NACK condition must generate a STOP  condition to abort the transfer  Note that as an al
79. m 3  volts to 1 8 volts     Devices may be powered by the bus Vpp or by another power source  Veus   as with  for  example  Smart Batteries  and will inter operate as long as they adhere to the SMBus  electrical specifications for their class  Figure 2 shows an example implementation of a  5 volt SMBus with devices powered by the bus Vpp inter operating with self powered  devices     O 2014 System Management Interface Forum  Inc  14 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Vo  5VD gt   lt  Veus   3 V              SMBus  Device    SMBCLK    SMBDAT  Figure 2  SMBus Topology    Vop may be 1 8 to 5 volts   10   and there may be SMBus devices powered directly by  the bus Vpp  Both SMBCLK and SMBDAT lines are bi directional  connected to a positive  supply voltage through a pull up resistor or a current source or other similar circuit as  shown in Figure 3  When the bus is free  both lines are high  The output stages of the  devices connected to the bus must have an open drain or open collector in order to  perform the wired AND function as shown in Figure 4  Care should be taken in the design  of both the input and output stages of SMBus devices  in order not to load the bus when    their power plane is turned off  i e  powered down devices must provide no leakage path to  ground     A device that wants to place a    zero    on the bus must drive the bus line to the defined logic  low voltage level  In order to place a logic    one  
80. ment  Protocol Specification  Part    Revision  1 3  1000 OXX X   Reserved by previous versions of the  SMBus specification for PCMCIA Socket  Controllers  4 addresses   These  addresses may be reassigned in future  versions of the SMBus specification   1000 100 X   Reserved by previous versions of the  SMBus specification for  VGA  Graphics  Controller  This address may be  reassigned in future versions of the  SMBus specification   1001 OXX X   Prototype Addresses System Management Bus Specification  V2 0  August 3  2000  1100 001 X   SMBus Device Default Address System Management Bus  Specification V2 0  August 3  2000  1111 OXX A   10 bit slave addressing  1111 1XX X   Reserved for future use             2014 System Management Interface Forum  Inc     All Rights Reserved    82 of 85    System Management Bus  SMBus  Specification Version 3 0    Appendix D  Changes This Revision    DISCLAIMER  The section is provided for reference only and for the convenience of the reader     No suggestion  statement or guarantee is made that the description of the changes listed below  is sufficient to design a device compliant with this document        A summary of the changes from Revision 2 0 to Revision 3 0 of the SMBus specification is  given below  This is not an exact list of every change made between the two documents  rather   itis a summary of the changes deemed significant by the editor     D 1 Maximum Bus Frequency    In SMBus 2 0  the maximum bus frequency was 100 kHz  In thi
81. mmand even if its AR flag is SET     8  The slave device only ACKs the PEC byte if it matches the value calculated on  data it received  if not it must NACK the PEC byte AND ignore the    Assign  Address    command  This behavior allows the host to determine that the slave  device successfully accepted the address without any further bus activity     This command utilizes the standard SMBus Block Write Protocol with PEC as  illustrated below     O 2014 System Management Interface Forum  Inc  57 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    7 1 1 8 1 8       3  S Address  1100 001b  Wr A Command  0000 0100b  A Byte Count  0001 0001b           8 1 8 1 8 1  Data 1  UDID Byte 15  A Data 2  UDID Byte 14  A Data 3  UDID Byte 13  A  8 1 8 1 8 1  Data 4  UDID Byte 12  A Data 5  UDID Byte 11  A Data 6  UDID Byte 10  A    eee    8 1 8 1 8    Data 7  UDID Byte 9  A Data 8  UDID Byte 8  A Data 9  UDID Byte 7     8 1 8 1 8    Data 10  UDID Byte 6  A Data 11  UDID Byte 5  A Data 12  UDID Byte 6     6 6 3 6    8 1 8 1 8 1  Data 13  UDID Byte 3  A Data 14  UDID Byte 2  A Data 15  UDID Byte 1   8 1 8 1 8                    Data 16  UDID Byte 0  A Data 17  Assigned Address    A PEC Byte    Figure 57  Assign address command  Get UDID  directed   Action  if  AV   1  then ACK PROCESS  else NACK REJECT   AR Flag  NO CHANGE  AV Flag  NO CHANGE    This command requests a specific ARP capable device to return its Unique Identifier   If the ARP Master detects
82. nana ncnnnnnnnns 22   4 2 5 SMBDAT low Umeout  ncnnnn nono naaa cnn nnn nn nn nn nana na ncn nn nani 22   4 3 DG  Specifications  To e At Do 22  4 3 1 Supply voltage requirements    23   4 3 2 SMBus branch circuit model  23   4 3 3 Low Power DC parameters    sise 24   4 3 4 High Power DC specifications anna 25   4 3 5 Additional common Low and High Power specifications                                         27   Layer 2     The Data Link Layer    sise 28  5 1 EI   i HE 28  5 1 1 Datavalidiy EE 28   5 1 2 START and STOP conditions    28   5 1 3 Busidle conditio niet  EE 29   5 2 Data  Transters On SMBuS cuevas ral dt Qi nl Cents ct  29  5 3 Clock Generation And Arbitratton   nono nonnnn cnn cnn nn nonnnacanncnnnns 30  5 3 1 SYNChrOnIzatIGN DEEG 30   5 3 2 OO A A TE 31   5 3 3 V   elei ei OCT ln e A AAA A A AAR ai 32   5 4 Data Transfer Formats iii a ENEE 34  Re NN rd EE 34  6 1 Usage Mod  lisme Mn AR mn d  ntn te EE a otic an desde te ite  NUE ER ote 34  6 1 1 Masterd  vices    s Ae EE teat nn A EE 34   6 1 2 Slave de VICO  nets RE iodo 35   6 1 3 ale EE 35   6 2 Device Identification     Slave Address  35  O 2014 System Management Interface Forum  Inc  3 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    6 2 1 UNIQUENESS required    ins 35   6 2 2 SMBUS address types iii 35   6 3 Using A DEVICE 37   6 4 Packet Error Checking o la dace ae dae del 37  6 4 1 Packet error checking implementation nn ccnnnnnccn nana nccnns 37   6 5 SEN tee t
83. ned Slave Address    The address assigned to a slave device by the ARP Master  This  address is then used for accesses to the device   s core function   Legal values are in the range 0010 000b to 1111 110b with some  exceptions  associated with reserved addresses and those  consumed by Fixed Slave Address devices         Bus Master    Any device that initiates SMBus transactions and drives the clock        Bus Slave    Target of a SMBus transaction which is driven by some master        Fixed Slave Address    A slave address that cannot be changed  Non ARP capable  SMBus devices fall into this category  The ARP Master must not  assign a used  i e  device is present on the bus  Fixed Slave  Address to an ARP capable device              FSA Fixed Slave Address  Host See Section 6 1 3   LSB Least Significant Bit  See MSB        Master  Master receiver   Master transmitter    See Section 6 1 1           MSB  PEC       Most Significant Bit  See LSB   Packet Error Code       All Rights Reserved    10 of 85       System Management Bus  SMBus  Specification Version 3 0             Term Definition   Persistent Slave Address   An assigned slave address that is retained through loss of device  power    PSA Persistent slave address   Reserved Reserved fields and bits within any of the data structures in this    document and in the SMBus ARP data structures in particular are  expected to be unused and ignored by software  Reserved bits  must written as O and read at 0 unless otherwise spec
84. nnncccnnncccnnnns 84    O 2014 System Management Interface Forum  Inc  7 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    1  Introduction    1 1 Overview    The System Management Bus  SMBus  is a two wire interface through which various  system component chips and devices can communicate with each other and with the  rest of the system  It is based on the principles of operation of the IC bus  Appendix B  provides a description of some of the ways the SMBus characteristics are different from  those of the PC bus     SMBus provides a control bus for system and power management related tasks  A  system may use SMBus to pass messages to and from devices instead of using  individual control lines  Removing the individual control lines reduces pin count   Accepting messages ensures future expandability     With System Management Bus  a device can provide manufacturer information  tell the  system what its model part number is  save its state for a suspend event  report  different types of errors  accept control parameters  and return its status     1 2 Audience    The target audience for this document includes but is not limited to     e System designers implementing the System Management Bus Specification in their  systems    e Digital IC design engineers designing chips to connect to the System Management  Bus    e Software engineers writing support code for System Management Bus chips    1 3 Scope    This document describes the electrical
85. o max   0 5 V     Note 2  The EC specification has several specifications for the clock and data signal fall time   One specification  tor  is measured at the pins of the driving device  The other  specification  tf  is measured on the bus  For details  see the notes attached to Table 9  of the 12C specification     O 2014 System Management Interface Forum  Inc  79 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Note 3  See Note 7 attached to Table 2 for the voltage limits used to measure rise and fall  time     Note 4  From the 12C specification     In order to drive full bus load at 400 kHz  6 mA lo  is  required at 0 6 V VOL  Parts not meeting this specification can still function  but  not at 400 kHz and 400 pF        O 2014 System Management Interface Forum  Inc  80 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Appendix C  SMBus Device Address Assignments    Table 17 lists the pre assigned and reserved SMBus device assignments     Table 17  Reserved and pre assigned SMBus addresses                                              Slave  Address Se Description Specification  Bits  7 1   0000 000 O  General Call Address 12C Bus Specification And User Manual   R01   0000 000 1 START byte PC Bus Specification And User Manual   R01   0000 001 X  CBUS address 12C Bus Specification And User Manual   R01   0000 010 X   Address reserved for different bus 12C Bus Specification And User Manual  format  
86. ock  bit by bit for  all masters involved during an arbitration process     A high to low transition on the SMBCLK line will cause all devices involved to start  counting off their LOW period and start driving SMBCLK low if the device is a  master  As soon as a device finishes counting its LOW period it will release the  SMBCLK line  Nevertheless  the actual signal on the SMBCLK may not transition  to the HIGH state if another master with longer LOW period keeps the SMBCLK line  LOW  In this situation the master that released the SMBCLK line will enter the  SMBCLK HIGH wait period  When all devices have counted off their LOW period   the SMBCLK line will be released and go HIGH  All devices concerned at this point  will start counting their HIGH periods  The first device that completes its HIGH  period count will pull the SMBCLK line LOW and the cycle will start again              T T   T  k HAT Ak HIGH1     3 ka k HIGH1                Ta K DL Tor a    Ten A ik Thich y                         SP Tse d    j   Li Thich Bus j    Tom                   H k   TLow_Bus Tow sus H       T Te To Ts Ts Ts LE To To    Figure 15  SMBus clock synchronization    In Figure 15  the interval between the first high to low transition of CLK1 and CLK2  must be less than  tiowmn    tsuoa   This way  a synchronized clock is provided for all  devices  where the SMBCLK LOW period is determined by the slowest device and  the SMBCLK HIGH period is determined by the fastest device     Arbitration    A m
87. ommunication on the bus resumes when the  system is out of the suspend state     10s of ms    Or much longer       No limit on this time duration 100s oi ms      SMBCLK    SMBDAT             SMBSUS        STOP E START    Figure 64  Using SMBus to Resume from Suspend    Since the SMBSUS  is an optional signal  some system devices may not know if the  system is in suspend mode or not  Such a device may assume that if both SMBCLK and  SMBDAT lines are high that the bus is alive and active  The possibility exists that this device  may try to send a critical message to another device that accepts the SMBSUS  signal and  is therefore asleep  Therefore it is important that a system is able to resume on a START  condition if a non suspendable master resides on the System Management Bus and that  master can send critical messages to suspended devices     A 2  SMBALERT     Another optional signal is an interrupt line for devices that want to trade their ability to master for  a pin  SMBALERT  is a wired AND signal just as the SMBCLK and SMBDAT signals are   SMBALERT  is used in conjunction with the SMBus Alert Response Address  ARA      A slave only device can signal the host through SMBALERT  that it wants to talk  The host  processes the interrupt and simultaneously accesses all SMBALERT  devices through the  Alert Response Address  Only the device s  which pulled SMBALERT  low will acknowledge  the Alert Response Address  The host performs a modified Receive Byte operation  The 7 bi
88. on Version 3 0    bus becomes idle again after certain time following a STOP condition or after both  the SMBCLK and SMBDAT lines remain high for more than tuich max     5 1 3 Bus idle condition    Bus idle is the condition during which the SMBCLK and SMBDAT lines are both  high  without any state transitions  for a time period specified as the minimum of the  following     e Tour from the last detected STOP condition or    e thiGH MAX   where teur and tHanmax are defined in Table 2  The latter timing parameter covers  the condition where a master has been dynamically added to the bus and may not  have detected a state transition on the SMBCLK or SMBDAT lines  In this case  the  master must wait long enough to ensure that a transfer is not currently in progress     5 2 Data Transfers On SMBus    Byte  Complete    Byte MASTER Releases  Complete Clock Line Here             ASA    a    START ACK From The Receive D ACK From The Receiver STOP  Condition  Date Line Held Low Clock Line Held Low  Date Line Held Low Condition  During Ninth Clock By Receiver While During Ninth Clock  Ise  Processing The Pulse   Just Received Byte          BIT 1          Figure 12  SMBus byte format    Every byte consists of 8 bits  Each byte transferred on the bus must be followed by  an acknowledge bit  Bytes are transferred with the most significant bit  MSB  first     The diagram below  Figure 13 illustrates the positioning of acknowledge  ACK  and  PS 14 illustrates not acknowledge  NACK  pulses re
89. on field  The version revision field serves multiple purposes   1  Identifies a UDID version to allow for future extendibility   2  Identifies the silicon revision level        Bit  7  Bit  6     Reserved   Reserved Bits  5 3  Bits  2 0     UDID Version Silicon Revision 1D        0   0   MSB LSB    Figure 52  Version Revision field  Table 7  Version Revision bit fields description                         Bit s   Field Description   7 6  Reserved Reserved bits are for future extendibility and must be a Ob   O 2014 System Management Interface Forum  Inc  50 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0          Bit s   Field Description   5 3  UDID Version These bits define the UDID version as defined here   000b Reserved  001b UDID version 1  defined for SMBus 2 0 release     010b 111b Reserved for future use    It is expected that the version will increment as the bit  definitions or protocols in this section change        2 0  Silicon Revision ID   These bits are used to designate the silicon revision level  The  vendor determines this value  The vendor is encouraged to  increment this value when silicon changes are made that  will might affect the software interface  e g  new features   changed interface  etc    In the event that all 8 encoded values  are exhausted  the vendor is encouraged to use a different  Device ID for the next revision                    6 6 1 3 Interface    The Interface field defines the SMBus version and th
90. ontroller  If a device does not acknowledge its own address how does  the system controller know if it is because the device is busy  has failed  or has been removed        2014 System Management Interface Forum  Inc  75 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    To prevent this confusion  the SMBus specifications require that a SMBus device always  acknowledge its own address  If a device that did acknowledge its address fails to do so the  system controller then knows that the device has either failed or has been removed     BA SMBus Protocols    The EC specification specifies only how to move bytes from one device to another  The  structure of messages and packets is left entirely to the device manufacturers     The SMBus specification defines command oriented protocols that must be used when one  SMBus device is communicating with another  Examples of these protocols are WRITE WORD   Section 6 5 4  or BLOCK READ  Section 6 5 7   Not all BC devices will support all of the  SMBus transaction protocols     B 5 REPEATED START Condition    As part of the SMBus protocols for reading data from a device the master generally uses a  REPEATED START condition  See  for example  the READ WORD protocol in Section 6 5 5   REPEATED START conditions may not be understood by some GC devices  An attempt to use  a SMBus protocol with a repeated START condition to read data from an PC device may yield  unexpected results     B 6 SMBus Low Power V
91. ose assigned address specifications for Smart Battery devices cannot be  used in Smart Battery applications     Other SMBus implementations do not rely solely on the device address to  identify a device s functionality  In these applications  devices may have  addresses that overlap with the purpose assigned addresses     The device manufacturer is forewarned that this may preclude use of that device  in other applications  In general  purpose assigned addresses should be avoided  except for devices that are intended to meet the specification for the  corresponding address es   The device manufacturer should consult the SMBus  WG to get the latest information on purpose assigned addresses as a guide to  whether their address assignment is disallowed in certain SMBus applications     6 2 2 3 Prototype addresses    The Prototype addresses  1001 OXXb  are reserved for device prototyping and  experimenting in applications that utilize purpose assigned addresses  They are  not intended for production parts and should never be assigned to any device     6 2 2 4 Miscellaneous device addresses    Manufacturers have produced and may continue producing SMBus compatible  devices for specific system purposes  for which they do not need to implement the  complete SMBus specification  or for which they do not require explicit support  from the operating system  Such devices  for example  may be port expanders  D A  circuits  etc     6 2 2 5 Dynamically assigned addresses    Version 2 0 of 
92. otocol With PEC  6 5 12 Write 64 protocol    The Write 64 protocol is used with commands that require sending to a slave device  up to 64 bits  8 bytes  of data     This protocol can be used to send less than 64 bits but the packet must be padded to  fill 64 bits  Data or meaningful bits are packed into the lower order bits and unused  higher order bits are filled with zeros  For example  a 40 bit value is transmitted in bits   39 0  with the most significant bit in bit  39   Bits  63 40  are all zeros        2014 System Management Interface Forum  Inc  46 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    8 1 8 1  Data Byte 1  Bits  7 0   A Data Byte 2  Bits  15 8   A       8 1 8 1  Data Byte 3  Bits  23 16   A  Data Byte 4  Bits  31 24   m    8 1 8 1          Data Byte 5  Bits  39 32    A Data Byte 6  Bits  47 40   JA           8 1    8 1  Data Byte 7  Bits  55 48   JAN Data Byte 8  Bits  63 56  MAP      Figure 46  Write 64 Protocol             1 8 1  EL Command Code D     N        8 1  Data Byte 1  Bits  7 0   A Data Byte 2  Bits  15 8   A    eee       8 1 8 1  Data Byte 3  Bits  23 16   A Data Byte 4  Bits  31 24   A    8 1 8 1  Data Byte 5  Bits  39 32     A Data Byte 6  Bits  47 40   A                8 1 8 1  Data Byte 7  Bits  55 48   A Data Byte 8  Bits  63 56   A Ze    8  PEC Byte AJP                   Figure 47  Write 64 Protocol With PEC  6 5 13 Read 64 protocol    The Read 64 protocol is used with commands that require reading
93. ow of data on the bus for each  type of protocol  such as READ BYTE or WRITE WORD  The elements that are used  to construct these diagrams are shown below in Table 1   Table 1  Transaction protocol diagram symbols and elements   Symbol Meaning       An unshaded rectangle with a number over it  represents one or more bits  as indicated by the  number  being sent from the master to the   La bel slave  A label may describe the data and may  include specific values        A shaded rectangle with a number over it  represents one or more bits  as indicated by the          A seven bit destination address being sent from  the master to one or more devices  such as  Address with the General Call Address  on the bus     8  8  number  being sent from the slave to the  Label master  A label may describe the data and may  include specific values   7             O 2014 System Management Interface Forum  Inc  120f85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0       Symbol    Meaning       7    A seven bit device address being returned to  the master from a slave device in response to  the Alert Response Address        The START condition sent from a bus master  device        A REPEATED START condition sent from a  bus master device        A STOP condition sent by a bus master device       The bit  0  of the address byte indicating the  device is being addressed to write data into the  device  Bit  0  will have a value of 0        The bit  0  of the addres
94. ow slower slave devices to cope with faster masters     At the bit level  a device may slow down the bus by periodically extending the  clock low interval     Devices are allowed to stretch the clock during the transfer of one message up to the  maximum limits described in the AC specifications of this document  Nevertheless        2014 System Management Interface Forum  Inc  32 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    devices designed to stretch every clock cycle periodically must maintain the fsus min  oi of 10 kHz  1 fsus min   100 us  in order to preserve the SMBus bandwidth     ERAN AACE  f      ARAL    AURA AAA PA  IV a a    Figure 17  Periodic clock stretching by a slave SMBus device                               f  K             SMBDAT          Condition    Clock LOW extension  or stretching   if necessary  must start after the SMBCLK high   to low transition within a tLow min   tsu pat interval  Devices designed to stretch the clock  on every bit transfer must maintain the minimum bus frequency Tous mn Of 10 kHz  A  slave device may opt to stretch the clock line during a specific bit transfer in order to  process a real time task or check the validity of a byte  In this case the slave device  must adhere to the trmeour and tLow sexr Specifications  Clock LOW extension may  occur during any bit transfer including the clock provided prior to the ACK clock pulse     A slave device may select to stretch the clock LOW period
95. protocols to communicate  The protocols are Quick  Command  Send Byte  Receive Byte  Write Byte  Write Word  Read Byte  Read  Word  Process Call  Block Read  Block Write and Block Write Block Read Process  Call  Write 32  Read 32  Write 64  and Read 64     Packet Error Checking    The Packet Error Checking mechanism improves reliability and communication  robustness  Implementation of Packet Error Checking by SMBus devices is optional  for SMBus devices but is required for devices participating in and only during the ARP  process  SMBus devices that implement Packet Error Checking must be capable to  communicate with the host and other devices that do not implement the Packet Error  Checking mechanism     Packet Error Checking  whenever applicable  is implemented by appending a Packet  Error Code  PEC  at the end of each message transfer  Each protocol  except for  Quick Command and the host notify protocol described Section 6 5 9  has two  variants  one with the Packet Error Code  PEC  byte and one without  The PEC is a  CRC 8 error checking byte  calculated on all the message bytes  including addresses  and read write bits   The PEC is appended to the message by the device that supplied  the last data byte     Packet error checking implementation    The SMBus must accommodate any mixture of devices that support Packet Error  Checking and devices that do not  A device that acts as a slave and supports the  PEC must always be prepared to perform the slave transfer with or wit
96. react to a START condition at the  fastest timings for its maximum rated bus speed as given in Table 2     Device timeout definitions and conditions    The trimeour  min parameter allows a master or slave to conclude that a defective device  is holding the clock low indefinitely or a master is intentionally trying to drive devices  off the bus  It is highly recommended that a slave device release the bus  stop driving  the bus and let SMBCLK and SMBDAT float high  when it detects any single clock  held low longer than trmeour  min  Devices that have detected this condition must reset  their communication interface and be able to receive a new START condition in no  later than trIMEOUT MAX     Figure 1 illustrates the definition of trmeout mn and trmeour max        TTIMEOUT MIN    At trimeout mi all devices on At trimeout max devices on  SMBCLK   the SMBus begin to reset the SMBus must be ready  No their SMBus interface for a START condition     4 2 3      trimeour max    H H    Figure 6  Timeout intervals  Master device clock extension definitions and conditions    Figure 7 illustrates the definition of the clock extension intervals  tLow mext and tLow sexr     The interval tLow  mexr is defined as the cumulative time a master device is allowed to  extend its clock cycles within one byte in a message as measured from     START to ACK  ACK to ACK  ACK to STOP     A system host may not violate tLow mexr except when caused by the combination of its  clock extension with the cloc
97. rs put a repeated START on the bus in the same bit position   arbitration should continue at each data bit     This mechanism requires that SMBus master devices participating in an arbitration  cycle monitor the actual state of the SMBDAT line during arbitration     If a master also incorporates a slave function and loses control of the bus in the  arbitration cycle during the address stage  it must check the actual address placed on  the bus in order to determine whether another master is trying to access it  In this case  the master that lost the arbitration must switch immediately to its slave receiver mode  in order to receive the rest of the message     SMBus Device  1  Loses Arbitration And  Stops Driving Data Line    AAAAAAAAN          SMBCLK  From  Master          SMBus  Device  1  Data Output    SMBus  Device  2  Data Output    SMBDAT       Condition    Figure 16  SMBus arbitration    During each bus transaction masters are still required to be able to recognize a  repeated START condition on the bus  A device that detects a repeated START  condition that it didn t generate must quit the transfer     Once a master has won arbitration  arbitration is disallowed until the bus is again idle   5 3 3 Clock low extending    SMBus provides a clock synchronization mechanism to allow devices of different  speeds to co exist on the bus  In addition to the bus arbitration procedure the clock  synchronization mechanism can be used during a bit or a byte transfer in order to  all
98. s  SMBus  Specification Version 3 0    6 5    6 5 1    6 5 2    Whether a device implements packet error checking may be determined by the  specification revision code that is present in the Specification Info   command for  a Smart Battery  Smart Battery Charger or Smart Battery Selector  See these  individual specifications for exact revision coding identities  lt may also be  discovered in the UDID  defined in Section 6 6 1  for other devices     Bus Protocols    Following is a description of the various SMBus protocols with and without a Packet  Error Code  Compliant devices need not support all the protocols defined in this  section  The results returned by such a device to a protocol it does not support are  undefined     Table 1 shows the symbols used to create the protocol diagrams in this section  Not   all protocol elements will be present in every command  For instance  not all packets   are required to include the Packet Error Code    A value shown within a field in the following diagrams is a mandatory value for that   field    The data formats implemented by SMBus are    e Master transmitter transmits to slave receiver  The transfer direction in this case  is not changed    e Master reads slave immediately after the first byte  At the moment of the first    acknowledgment  provided by the slave receiver  the master transmitter becomes  a master receiver and the slave receiver becomes a slave transmitter     e Combined format  During a change of direction within 
99. s byte indicating the  device is being addressed to read data from the  device  Bit  0  will have a value of 1           2     3    Le  ye    ER      Z           General representation of bit  0  of the address  byte     An Acknowledge  ACK  bit sent from the host       A Not Acknowledge  NACK  bit sent from the  host       An Acknowledge  ACK  bit sent from a slave  device          E  E i        A Not Acknowledge  NACK  bit sent from a  slave device          2014 System Management Interface Forum  Inc     All Rights Reserved    13 of 85       System Management Bus  SMBus  Specification Version 3 0       Symbol Meaning       1 A    don   t care    bit that may have a value of  0 or 1 sent from the slave device to the host    X when responding to the Alert Response  Address  ARA     Figure 1 shows an example of a generic SMBus transaction data structure  Note  the START and STOP conditions are transitions  not bits  and are shown without a  bit count number above the symbol  When shown in a transaction diagram  the  REPEATED START is also a transition  not a bit  and is shown without a bit count  above the symbol                 7 1 1 8 1    5  Seene LL Ins LL    Figure 1  Generic transaction diagram    3  General Characteristics    SMBus is a two wire bus  Multiple devices  both bus masters and bus slaves  may be  connected to a SMBus segment  Generally  a bus master device initiates a bus  transfer between it and a single bus slave and provides the clock signals  One  except
100. s of the referenced documents at the time the  device is released to manufacturing apply     2 2 Applicable Documents  Applicable documents include information that is  by extension  part of this specification   None in this revision     2 3 Reference Documents    Reference documents have background or supplementary information to this   specification  They do not include requirements or specifications that are considered part   of this document     R01  The   C bus Specification And User Manual  NXP Semiconductors  Revision 6  4  April 2014    R02  Advanced Configuration and Power Interface Specification  Hewlett Packard  Corporation  Intel Corporation  Microsoft Corporation  Phoenix Technologies Ltd    and Toshiba Corporation  Revision 5 0a  13 November 2013    R03  Conventional PCI  PCI Special Interest Group  Revision 3 0    R04  PCI Express  PCI Special Interest Group  Revision 3 0    R05  SMBus Control Method Interface Specification  System Management Interface  Forum  Version 1 0  10 December 1999    R06  PMBus    Power System Management Protocol Specification Part       General  Requirements  Transport And Electrical Interface  System Management Interface  Forum  Revision 1 3  March 2014       2014 System Management Interface Forum  Inc  9 of 85  All Rights Reserved    2 4       2014 System Management Interface Forum  Inc     Definitions Of Terms    System Management Bus  SMBus  Specification Version 3 0    The following terms are defined with respect to this specific
101. s revision  three classes of bus  speeds are introduced with maximum bus frequencies of 100 kHz  400 kHz  and 1 MHz  Section  4 2 and Table 2     D 2 Electrical Drive Levels    The organization of the electrical drive levels was changed to accommodate the higher bus  frequencies  The Low Power levels were retained  Table 3  but the High Power drive levels  were updated to match the new higher operating frequencies  Table 4      D 3 Data Hold Time    A key requirement for the SMBus that the data line  SMBDAT  must not change while the clock  line  SMBCLK  is high as shown in Figure 67  If a device on the bus were to detect SMBDAT  transitioning from low to high while SMBCLK was high  this would interpreted as a STOP  condition  lf a device were to detect SMBDAT transitioning from high to low when SMBCLK was  high  this would interpreted as a START or REPEATED START condition  In either case the bus  transaction that was in progress would be disrupted     SMBCLK    SMBDAT       Figure 67  Showing SMBDAT Remaining Stable Until SMBCLK Is Low    The SMBus specifications  through Version 2 0  have specified a data hold time  tHp par  equal to  the maximum specified fall time of the SMBCLK  This essentially required the device  transmitting data to either monitor the clock signal or add an internal delay so that the data hold  time specification would always be met  An advantage to this requirement is that the data hold is  easily observable in a system with an oscilloscope or logic
102. se of  device address contention the designer may use either programmable features  implemented in SMBus devices to resolve such contention or and multiple SMBus  branches within the same system to spread devices that use the same address     There are several types of addresses currently in use in SMBus systems   6 2 2 1 Reserved addresses    SMBus  Access bus and UC reserve several addresses for specific bus functions  as defined in Table 17  These addresses must not be used by or assigned to any  SMBus slave device unless otherwise detailed by this specification     All other addresses are available for address assignment for dynamic address  devices and or for miscellaneous devices  Miscellaneous device addresses are  discussed in Section 6 2 2 4     6 2 2 2 Purpose assigned addresses    These addresses are assigned by the SMBus Working Group to specific types of  devices  Each device type that obtains an assigned address has to have a SMBus    O 2014 System Management Interface Forum  Inc  35 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    specification associated with it  Some systems using SMBus assume that if a device  exists at a purpose assigned address then the device complies with the  associated specifications for that address  For example  SMBus application to  Smart Battery implementations assumes that Smart Battery devices and controllers  are at their purpose assigned addresses  Thus  devices that do not meet the  purp
103. ssigned Address  Set The  ag Set  Men Address Resolved And  Address Valid Flags  Yes Yes  Yes Directed Is The  Reset Address Received Return UDID  Command  Flag Set   es  Step 15 No 23 Gs 24 Return The  Adress Valid Yes   Current Slave Address  27 Directed Flag Set  For The Device Slave  Y 7 i  Get UDID E Address Field  Command   No  N 25 Return OxFF For The  28 9 Device Slave Address Field  Handle 29  Return UDID And  e Illegal Current Slave Address  Command          Figure 62  ARP capable device behavior       2014 System Management Interface Forum  Inc   All Rights Reserved    67 of 85    System Management Bus  SMBus  Specification Version 3 0    6 6 3 13    6 6 3 14    Enumeration rules    Any device may enumerate the bus provided that the device is intelligent and  capable of doing so  Additionally  the enumerating device must provide     snooping    capabilities to guarantee that multiple devices aren t  enumerating ARPing at the same time  An enumerator must adhere to the following  rules    1  If an enumerator sees a    Prepare to ARP    or    Get UDID    command it must  immediately stop enumerating    2  An enumerator must monitor the bus for ARP commands for at least 2  seconds before beginning the enumeration process with the    Prepare to ARP     command    3  If an enumerator sees an unassigned address then it must issue a host notify  command and stop enumerating     Example scenarios    The ARP can be illustrated by the following examples  Note that the UDID v
104. t  device address provided by the slave transmit device is placed in the 7 most significant bits of  the byte  The eighth bit can be a zero or one        2014 System Management Interface Forum  Inc  73 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    7  i       7 1 1  S   Alert Response Address  Rd MA Address X  N  P       Figure 65  A 7 bit Addressable Device responds to an ARA  7 1 1 7 1 1 8 1  S   AlertResponse Address  Rd MA Device Address XJA PEC Byte NJP       Figure 66  A 7 bit Addressable Device responds to an ARA with PEC    If more than one device pulls SMBALERT  low  the highest priority  lowest address  device  will win communication rights via standard arbitration during the slave address transfer     After receiving an acknowledge  ACK  from the master in response to its address  that device  must stop pulling down on the SMBALERT  signal  If the host still sees SMBALERT  low when  the message transfer is complete  it knows to read the ARA again     A host which does not implement the SMBALERT  signal may periodically access the ARA        2014 System Management Interface Forum  Inc  74 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Appendix B  Differences between SMBus and VC    The SMBus and PC bus are very similar and are generally interoperable  However  there  are several differences with which a system engineer should be familiar  This section  describes several of differen
105. t can assume that there are no ARP capable devices present on  the bus  Retries are recommended in case bus noise causes an erroneous NACK   This command utilizes the standard SMBus Send Byte Protocol with PEC as  illustrated below   7 1 1 8 1 8 1  S Address  1100 001b  Wr A Command  0000 0001b  A PEC Byte AJP  Figure 54  Prepare to ARP command  6 6 3 3 Reset device  general   Action  always ACK PROCESS  AR Flag  CLEAR  AV Flag  if  non PSA  then CLEAR  else NO CHANGE  This command forces all non PSA  ARP capable devices to return to their initial  state  That is  they must clear their AR  Address Resolved  and AV  Address Valid   flags  those devices that support the Persistent Slave Address must clear their AR  flag  An ARP capable device that implements a random number as part of its UDID  must regenerate its random number upon receipt of this command  All ARP capable  devices must acknowledge all bytes in this SMBus packet  If the ARP Master detects  that any of the bytes have not been acknowledged then it can assume that there are  no ARP capable devices present on the bus   This reset is just for the ARP functions  and is not intended as a general device  reset   This command utilizes the standard SMBus Send Byte Protocol with PEC as  illustrated below      2014 System Management Interface Forum  Inc  55 of 85    All Rights Reserved    Address  1100 001b  Command  0000 0010b  PEC Byte    6 6 3 4    System Management Bus  SMBus  Specification Version 3 0    7 LA 8 1 8   
106. ta and waits for the  slave to return a value dependent on that data  The protocol is simply a Write Word  followed by a Read Word without the Read Word command field and the Write   Word STOP bit     Note that there is no STOP condition before the repeated START condition  and  that a NACK signifies the end of the read transfer           7 1 1 8 1  Command Code  8 1 8  Data Byte Low A Data Byte High A  7 1 1 8 1 8 1  Sr Address Rd MA   Data Byte Low   A   Data Byte High   N   P                     Figure 33  Process Call          7 ds  lt a 8  S Address Wr A Command Code A  8 1 8 1  Data Byte Low Data Byte High  7 1 1 8 1  Sr Address Rd A Data Byte Low A  8 1 8 1    MEC Ol E HD  Figure 34  Process Call with PEC    6 5 7 Block Write Read    The Block Write begins with a slave address and a write condition  After the  command code the host issues a byte count which describes how many more  bytes will follow in the message  lf a slave has 20 bytes to send  the byte count field  will have the value 20  14h   followed by the 20 bytes of data  The byte count does not  include the PEC byte  The byte count may be 0  A Block Read or Block Write is  allowed to transfer a maximum of 255 data bytes     O 2014 System Management Interface Forum  Inc  42 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    7 1 1 8 1 8  S Address Wr MA Command Code A Byte Count N       8 1    8 1 8 1  CC Peer Ir    Figure 35  Block Write       7 1 1 8 1 8 1  Command Code 
107. te 0  A   Data 17  Device Slave Address    A PEC Byte NJP  Figure 56  Get UDID  general  command     2014 System Management Interface Forum  Inc  56 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    6 6 3 5    Assign address   Action  always ACK  if  UDID match  then PROCESS   AR Flag  SET if UDID matches    AV Flag  SET if UDID matches     The ARP Master assigns an address to a specific device with this command   Since this command utilizes a particular device   s UDID only that device will adopt  the new address  All ARP capable devices must monitor the UDID bytes in this  packet  all bytes except the assigned address byte   Once a device determines  that it is not the target of the command  due to a UDID bit or byte mismatch  it must  NACK the current byte  if possible  or the next byte  A slave device matching all but  the last UDID byte has the choice to NACK the last UDID byte or the subsequent  assigned address byte  If the ARP Master detects a NACK for any byte then it must  assume that the target device is no longer present  It is suggested that the ARP  Master consider retrying the command in order to guard against noise causing a  present device to be ignored     A slave device that matches the entire UDID must immediately adopt the new  slave address  lt must reprogram its Persistent Slave Address  if applicable  Bit O   LSB  of the Assigned Address field must be ignored     NOTES   7  A slave device must respond to this co
108. te protocol    pl    7 1 8 1 8 1    CAI   er wave ee    Figure 22  Send Byte protocol with PEC    pl    6 5 3 Receive Byte    The Receive Byte is similar to a Send Byte  the only difference being the direction  of data transfer  A simple device may have information that the host needs  lt can do  so with the Receive Byte protocol  The same device may accept both Send Byte  and Receive Byte protocols  A NACK  a    1    in the ACK bit position  signifies the end  of a read transfer          7 1 8 1    ss LL LI      Figure 23  Receive Byte protocol    E   gt     7 1 8 1    ies TA        8 1    PEC Byte DND         E   gt              Figure 24  Receive Byte protocol with PEC  6 5 4 Write Byte Word    The first byte of a Write Byte Word access is the command code  The next one or  two bytes  respectively  are the data to be written  In this example the master sends  the slave device address followed by the write bit  The device acknowledges and  the master delivers the command code  The slave again acknowledges before the  master sends the data byte or word  low byte first   The slave acknowledges each  byte  and the entire transaction is finished with a STOP condition     7 1 1 8 1 8 1     nates w cose DI fens Dr    Figure 25  Write Byte protocol  7 1 1 8  S Address Wr A Command Code A       8 1 8 1  Data Byte Low Data Byte High BAS P      Figure 26  Write Word protocol       2014 System Management Interface Forum  Inc  40 of 85  All Rights Reserved    System Management Bus  SMB
109. ternative  the slave device can  extend the clock LOW period within the limits of this specification in order to  complete its tasks and continue the transfer     e The slave device detects an invalid command or invalid data  In this case the slave  device must NACK the received byte  The master upon detection of this condition  must generate a STOP condition and retry the transaction     e  f amaster receiver is involved in the transaction it must signal the end of data to the  slave transmitter by generating an NACK on the last byte that was clocked out by the  slave  The slave transmitter must release the data line to allow the master to  generate a STOP condition     The latter mechanism is one way for a device to detect whether a slave transmitter  implements Packet Error Checking  See Section 6 4 for more information on Packet  Error Checking     5 3 Clock Generation And Arbitration   5 3 1 Synchronization  A situation may occur in which more than one master is trying to place clock  signals on the bus at the same time  The resulting bus signal will be the wired AND  of all the clock signals provided by the masters    O 2014 System Management Interface Forum  Inc  30 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    Less Than  TLow min     Tsu DaT MIN     SMBus  Master  1  Clock Output    SMBus  Master  2  Clock Output    sMBCIK        5 3 2          It is important for the bus integrity that there is a clear definition of the cl
110. than it has a fixed address  so proceed to step 12  Otherwise  proceed to step 10     The device possesses a valid slave address  However  the ARP Master must  check this address against the Used Address Pool to insure that no other device  has already been assigned the same address  If the received Device Slave  Address is found in the Used Address Pool then proceed to step 11  If not   then the device can keep its current slave address but needs  acknowledgement from the ARP Master so proceed to step 12     Select a slave address that is not in the Used Address Pool and proceed to  step 12    Send the    Assign Address    command with the UDID returned by the device in  the    Get UDID    command packet    Check for acknowledgement of all bytes in the    Assign Address    command  packet  If any byte was not acknowledged then the ARP Master assumes the    O 2014 System Management Interface Forum  Inc  61 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    device is no longer present  proceed to step 6 to determine if there are more  devices requiring address resolution  If all bytes were acknowledged then the  ARP Master assumes that the device has accepted the address assignment    proceed to step 13     14  The device now has a valid slave address  The ARP Master must add this  address to the Used Address Pool  Proceed to step 6 to determine if there are  more devices requiring address resolution     15  The ARP Master checks to see if
111. the SMBus specification introduced the concept of dynamically  assigned addresses  This is detailed in Section 6 5 10     6 2 2 6 SMBus Alert Response Address    The SMBus Alert Response Address  0001 100b  can be a substitute for device  master capability  See Appendix A for details     6 2 2 7 SMBus Device Default Address    The SMBus Device Default Address is reserved for use by the SMBus Address  Resolution Protocol  which allows addresses to be assigned dynamically  See  Section 6 5 10 for details    6 2 2 8 SMBus Host Address    The host has the lowest legitimate address so that messages going to the host  have the highest priority with respect to bus arbitration     6 2 2 9 10 bit Slave Addresses    All 10 bit slave addresses are reserved for future use and are outside the scope  of this specification     O 2014 System Management Interface Forum  Inc  36 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    6 3    6 4    6 4 1    6 4 1 1    Using A Device    A typical SMBus device will have a set of commands by which data can be read  and written  All commands are 8 bits  1 byte  long  Command arguments and return  values can vary in length  Accessing a command that does not exist or is not  supported may cause an error condition  In accordance with this specification  the Most  Significant Bit is transferred first     There are fifteen possible command protocols for any given device  A slave device  may use any or all of the fifteen 
112. thin or  after the current data byte in the transfer process  Devices that have detected this condition must reset their communication and  be able to receive a new START condition no later than trmeour max  Typical device examples include the host controller  and  embedded controller  and most devices that can master the SMBus  Some simple devices do not contain a clock low drive circuit   this simple kind of device typically may reset its communications port after a start or a stop condition     A timeout condition can only be ensured if the device that is forcing the timeout holds the SMBCLK low for trmeour max Or longer     Note 4  Lucu wax provides a simple guaranteed method for masters to detect bus idle conditions  A master can assume that the  bus is free if it detects that the clock and data signals have been high for greater than tyigh max     Note 5  tLow sexr is the cumulative time a given slave device is allowed to extend the clock cycles in one message from the initial  START to the STOP  It is possible that another slave device or the master will also extend the clock causing the combined clock    O 2014 System Management Interface Forum  Inc  19 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    low extend time to be greater than tLow sexr  Therefore  this parameter is measured with the slave device as the sole target of a  full speed master     Note 6  tLowmexr is the cumulative time a master device is allowed to extend i
113. ts clock cycles within each byte of a message as  defined from START to ACK  ACK to ACK  or ACK to STOP  It is possible that a slave device or another master will also extend the  clock causing the combined clock low time to be greater than tLow mext on a given byte  This parameter is measured with a full  speed slave device as the sole target of the master     Note 7  The rise and fall time measurement limits are defined as follows   Rise Time Limits   Vin max   0 15  to  Vii  min   0 15   Fall Time Limits   Vin min   0 15  to  Vii max   0 15   Note 8  Devices must provide a means to reject noise spikes of a duration up to the maximum specified value     O 2014 System Management Interface Forum  Inc  20 of 85  All Rights Reserved    4 2 1    4 2 2    System Management Bus  SMBus  Specification Version 3 0    General timing conditions    The SMBus is designed to provide a predictable communications link between a  system and its devices  However some devices  such as a Smart Battery using a  microcontroller to support bus transactions and to maintain battery data  may  require more time than might normally be expected  These specifications take such  devices into account while maintaining relatively predictable communications  The  following are general comments on the SMBus    timing     e The bus is at 0 kHz when idle  The fsusmn Specification is intended to dissuade  components from taking too long to complete a transaction     e Every device must be able to recognize and 
114. um bus segment capacitance  and  maximum bus segment leakage current  The requirement for sink current also  determines the minimum value of the pull up resistor Rp that can be used in SMBus  systems     Additional common Low and High Power specifications  SMBus    back powering    considerations    Unpowered devices connected to either a Low Power or High Power SMBus  segment must provide  either within the device or through the interface circuitry   protection against back powering the SMBus  Unpowered Low Power devices  connected to High Power segments must meet leakage specifications in Section  4 3 3  Unpowered High Power devices must meet the leakage specifications in  Section 4 3 4     Power on reset    SMBus devices detect a power on event in one of three ways   e By detecting that power is being applied to the device   e By an external reset signal that is being asserted or    e For self powered or always powered devices  by detecting that the SMBus is  active  clock and data lines have gone high after being low for more than  2 5 seconds      A SMBus device must respond to a power on event by bringing the device into  an operational state within Tror  defined in Table 2  after the device has been  supplied power that is within the device   s normal operating range  Self powered or  always powered devices  such as Smart Batteries  are not required to do a complete  power on reset but must be in an operational state within 500 milliseconds after  the SMBus becomes act
115. urer   s ID as assigned by the SBS   Implementers    Forum or the PCI SIG     95 80  Device ID The device ID as assigned by the device manufacturer    identified by the Vendor ID field      79 64  Interface Identifies the protocol layer interfaces supported over the   SMBus connection by the device  For example  ASF and IPMI     63 48  Subsystem This field may hold a value derived from any of several  Vendor ID sources    e The device manufacturer   s ID as assigned by the SBS  Implementers    Forum or the PCI SIG    e The device OEM s ID as assigned by the SBS Implementers     Forum or the PCI SIG    e A value that  in combination with the Subsystem Device ID   can be used to identify an organization or industry group that  has defined a particular common device interface  specification     47 32  Subsystem Device   The subsystem ID identifies a specific interface   ID implementation  or device  The Subsystem ID is defined by  the party identified by the Subsystem Vendor ID field    31 0  Vendor specific ID   A unique number per device  See detail below                    6 6 1 1 Device capabilities field    The Device Capabilities field serves multiple purposes        2014 System Management Interface Forum  Inc  49 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    1  Reports generic SMBus capabilities    2  Guarantees order of ARP resolution  Because a    zero    bit wins arbitration over a     1    bit  and the Address Type bits are t
116. us  Specification Version 3 0          7 1 1 8  S Address Wr A Command Code A  8 1 8  Data Byte A PEC Byte AJP    Figure 27  Write Byte protocol with PEC  7 1 1 8  S Address Wr A Command Code A                 8 1 8 8 1    D veste D ceux Yee DIr  Figure 28  Write Word protocol with PEC    6 5 5 Read Byte Word    Reading data is slightly more complicated than writing data  First the host must  write a command to the slave device  Then it must follow that command with a  repeated START condition to denote a read from that device s address  The slave  then returns one or two bytes of data   Note that there is no STOP condition before the repeated START condition  and  that a NACK signifies the end of the read transfer   7 1 1 8  S Address Wr A Command Code A       7 1 1 8 1  S moes Tr y    Figure 29  Read Byte protocol    7 1 1 8 1  S   Address wr A   Command Code  A                   7 1 1 8 1 8 1  S  ie p DRE         Figure 30  Read Byte protocol with PEC                         7 1 1 8 1  Command code  H    7 1 1 8 1 8 1    Sr Address Ra A Data Byte Low   A   Data Byte High NIP  Figure 31  Read Word protocol     2014 System Management Interface Forum  Inc  41 of 85    All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0          7 1 1 8 1  S Address Wr A Command Code A  7 1 1 8 1  ST moes p  8 1 8 1  Data Byte High A PEC Byte NJP    Figure 32  Read Word protocol with PEC    6 5 6 Process Call    The Process Call is so named because a command sends da
117. ution Protocol  ARP   possesses the following attributes     Address assignment utilizes the standard SMBus physical layer arbitration  mechanism     Assigned addresses remain constant while device power is applied  address retention  through device power loss is also allowed        2014 System Management Interface Forum  Inc  48 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    No additional SMBus packet overhead is incurred after address assignment   i e   subsequent accesses to assigned slave addresses have the same overhead as  accesses to fixed address devices      Any SMBus master can enumerate the bus   6 6 1 Unique Device Identifier  UDID     In order to provide a mechanism to isolate each device for the purpose of address  assignment each device must implement a unique device identifier  UDID   This  128 bit number is comprised of the following fields                                                        8 Bits 8 Bits 16 Bits 16 Bits 16 Bits  Device Version  Vendor ID Device ID Interface  Capabilities Revision  MSB  16 Bits 16 Bits 32 Bits  Subsystem Subsystem G      Vendor ID Device ID   mongole pectic IE  LSB  Figure 50  UDID  Table 5  UDID bit fields descriptions  Bits Field Description   127 120    Device Capabilities   Describes the device   s capabilities  See detail below    119 112    Version   Revision UDID version number  and silicon revision identification  See  detail below    111 96    Vendor ID The device manufact
118. ver  a  32 bit pre assigned unique ID is recommended     3  If a random number is implemented in this field  Random Number Requirements  must be met     4  Devices that support a fixed device address must still implement this field but not  uniquely     Uniqueness is important to guarantee that two like devices are identified discretely  It  is the responsibility of the device system manufacturer to determine the  possibility of like devices  and the mechanism for providing uniqueness via the  UDID and slave address fields     Random number requirements    If a random number is utilized the following requirements must be met   1  It must be at least 16 bits in length   2  The device is not allowed to support a persistent slave address        2014 System Management Interface Forum  Inc  52 of 85  All Rights Reserved    System Management Bus  SMBus  Specification Version 3 0    3  The device is not allowed to support fixed addresses   If the device has a fixed  address mode  the Vendor Specific ID should be a constant  and therefore not  random     this is required to guarantee that the SMBus ARP resolution order is  maintained     4  The random number must be retained while the device has power  with the  exceptions described in items 5 and 6     5  The random number must be regenerated when the device receives the Reset  Device command     6  The random number must be regenerated when the device senses a bus  collision during a read operation directed to its Assigned Slave Ad
    