Home

380340 Heavy Duty Datalogger Manual

image

Contents

1. Press the PAUSE button to halt the transfer When the Data LED ceases blinking the data points have been transferred After the data points have been transferred turn off the datalogger Data will remain in the datalogger as long as the batteries are fresh The data points are transferred to the file named in step 4 above To view the transferred data click the VIEW DATA button on the software screen The file stored on the PC can now be opened in other applications such as spreadsheet word processor database or graphics programs Battery Replacement When the Battery Status LED indicator is NOT lit the batteries should be replaced Slide the rear battery cover off in the direction of the arrow Replace the four AA batteries and secure the battery compartment cover Calibration and Repair Services Extech offers repair and calibration services for the products we sell Extech also provides NIST certification for most products Call the Customer Service Department for information on calibration services available for this product Extech recommends that annual calibrations be performed to verify meter performance and accuracy T Support Hotline 781 890 7440 Tech support Ext 200 Email support extech com Repair Returns Ext 210 Email repair extech com Website www extech com Copyright 2004 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any
2. Datalogger OFF 0 switch position Slide the Auto Man Out switch to the Auto position Slide the Time switch to the S seconds M minutes or H hours range position depending on the data sampling rate desired If this is the first time the datalogger is being used reset erase the datalogger s memory per the Reset Function section below Power the datalogger slide switch to the I position To set the sample recording rate press and hold the SET button and while holding the SET button press the INC 1 button to adjust the units digit use the INC 10 button to adjust the tens digit Release the SET button when complete You can set the interval from 1 to 99 seconds 1 to 99 minutes or 1 to 99 hours Note Always set the AUTO and TIME switches to the desired setting before turning on the Datalogger Begin Automated Datalogging k Press the PAUSE button to begin logging measurements The PAUSE LED will switch off and the DATA LED will blink each time a measurement is recorded Press the PAUSE button a second time to pause datalogging PAUSE LED lights Use the PAUSE button to toggle recording ON resume and OFF pause When datalogging is resumed new readings are recorded right where the datalogger left off so that readings are not overwritten RESET Function The RESET function erases all of the stored Datalogger readings 1 2 3 4 Connect the datalogger to the meter as prev
3. D indicator DATA recording LED indicator Oo OO OV aR GN AC adaptor input FRONT PANEL VIEW TOP VIEW TOP VIEW 1 Optically isolated INPUT jack int eee ue jE 2 Optically isolated OUTPUT jack 3 Non isolated INPUT jack 4 Non isolated OUTPUT jack SLIDE SWITCH AND BUTTON DESCRIPTION 1 Power slide switch IEON O OFF 2 Sample Rate slide switch Secs Mins Hours 3 Automatic or Manual Recording I S AUTO o M MAN H OUT and Data Output slide switch 4 RESET memory clear and sampling rate RESET gt PAUSE INCrement left LCD digit button a a a INCrement right LCD digit button INC 10 INC 1 SET 6 Hold the SET button while pressing 5 PAUSE recording and sampling rate an increment button to change the sample rate Datalogger Operation Note The Heavy Duty Meters have an Auto Shutoff feature that automatically turns off the meter after 10 to 30 minutes depending on the model This feature should be disabled during a datalogging session Press the RECORD button on the meter to disable the Auto Shutoff feature Automated Datalogging Preparation This function permits the Datalogger to automatically collect readings at the sample rate set by the user 1 Connect the Datalogger s IN port to the Heavy Duty Meter as shown in the illustration The supplied cable connects the Heavy Duty meter to the Datalogger Use the Isolated or Direct non isolated port on the Datalogger as desired Turn the
4. User s Guide EXTECH INSTRUMENTS Heavy Duty Datalogger Module Model 380340 EXTECH 380340 DATALOGGER Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies on sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website at www extech com click on Contact Extech and go to Service Department to request an RA number A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or im
5. Windows Datalogger Software Install the supplied software from the Windows program CD ROM using the instructions provided on the CD ROM The following software screen will appear w DLISDI for Windows Setup Procedure 1 Select Comm Port Data Transfer Status Data Transfer OK 116 2 Input Duta File Name 3 Press Start Button 4 Preso RESET Key on Yaw Umt DATALOGGER 109 mun 103 Mimin 3 103 fimin 9 Nitin Software Screen Description OaE E NO COM Port Selection Click on appropriate port COM1 or COM2 Data Transfer Status Transferred Data View Data File Name type desired filename Number of Data points Instructional steps describing the data transfer process additional steps are listed in the next section Function buttons START click to begin data transfer VIEW DATA click to see all transferred data as shown in item 3 above and EXIT click to close program Begin Data Transfer To transfer data from a Heavy Duty meter to a PC follow the instructions shown below ZOND p NH Slide the Auto Man Out Datalogger switch to the OUT position Power the Datalogger Select COM 1 or COM 2 on the software screen Type a file name in the Data File Name field on the software screen Click on the START key in the software window Press the RESET button on the Datalogger to begin the data transfer The DATA LED will rapidly blink as the data transfer takes place
6. form
7. iously described Set the Auto Man Out switch to either the AUTO or MAN position Power the datalogger and the meter Press and hold the RESET button for approx 4 seconds until 00 is displayed NOTE It may take up to three RESETS to clear all the datalogger memory levels To be sure repeat the RESET procedure three times in succession FULL Indicator The FULL indicator lights when 7999 data points have been recorded NOTE Data will remain in memory until the Datalogger is RESET see previous section or until the batteries are removed Manual Datalogging Manual datalogging allows the user to record one reading at a time 1 Turn the Datalogger OFF 0 switch position 2 Slide the Auto Man Out switch to the MAN position 3 Power the Datalogger l position Note that it is very important to set the MAN switch before turning the Datalogger on Press the PAUSE button to log one measurement When the Datalogger memory is full 7999 readings the FULL indicator will light 6 To erase reset the Datalogger memory refer to the Reset Function section earlier in this manual Transferring Data to a PC Once data is collected the next step is to connect the Datalogger to a PC and transfer the collected readings Hardware Connection Connect the Datalogger s OUT port to the PC COM port as shown via the supplied cable 3 5mm phono to DB 9 cable Use either the Isolated or Direct non isolated output port
8. plied Introduction Congratulations on your purchase of Extech s 380340 Datalogger Module The Datalogger connects to and records data from Extech Heavy Duty Series Meters The sample rate at which data is recorded is user selectable Readings stored in the Datalogger can later be transferred to a PC using the supplied software and communication cables This professional device with proper care will provide years of safe reliable service Specifications Input type RS 232 data stream Data storage 8000 readings 16 bits each Display 0 5 red 2 digit LED 100 counts 0 99 Adjustable Sample Rate Seconds 1 to 99 Minutes 1 to 99 Hours 1 to 99 Software compatibility Windows 98 2000 Me and XP Operating Systems Internal Clock Crystal oscillator Memory Non volatile Data is retained at power down Batteries Four 1 5V AA batteries alkaline or heavy duty type Battery life 36 hours continuous typical Power consumption Approx 20 to 54 mA DC Operating temperature 32 to 122 F 0 to 50 C Operating humidity lt 80 RH Weight 0 45 Ibs 205g including battery Dimensions 5 2 x 2 8 x 1 0 131 x 70 x 26mm H x W x D Meter Description FRONT PANEL VIEW 1 Input Output terminals PAUSE LED indicator LCD Display Battery LED status indicator Slide switches and buttons Battery compartment on rear Memory FULL LE