1. MIDMARI lt Versaflo 200 Syringe Pump User s Manual For Veterinary Use Only S wo 7 ON v TEC COU COL TETI RU LITT T ua 1 Si l Sop l a J A VERSAFLO 200 POWER ALARM SET TIME tmin ca s MEAN END SS 4 B 12 16 20 RAPID RUN SYRINGE PUMP y F 2 78 ie oes S Midmark Corporation 60 Vista Drive Box 286 Versailles OH 45380 0286 Customer Service and Technical Service TEL 1 800 MIDMARK 1 800 643 6275 www midmark com Versaflo 200 High Volume Syringe Pump Features v Capability to Load 100ml Syringe With 100ml syringe you can treat larger animals with larger volumes continuously without changing syringes Y Broad Infusion Capability Delivers general fluids blood fluid nutritionals v Alarms Message Light 4 alarms via bright light indicators and sound Table of Contents General IM LORNA CON coeur pao eod QU eodd e a EROR s Ua Go Ue phun deeds opted 2 ise 2 SDOCITICaEIOlSio ioo n adinim EE m in ck aA deme 3 Keypad Description enne nennen nnns 4 Operation Procedures iei iia LOL LP EET EEUU AC 5 SO se sce T T TETTE 6 General Information This high volume syringe pump is a conventional device for specialty practices universities and general practices A wide variety of clinical departments such as internal medicine cardiology and oncology require being equipped with this type of syringe pump This pump is mainly
2. is illuminated in red and the alarm buzzer sounds To silence the alarm press the RUN YSTOP button The battery indicator light orange indicates the driver is using built in battery power This light and AC power light green will blink together if battery is Low AC power light green indicates the pump is connected to mains AC power and is charsings the battery Operation Procedures 1 Load the syringe with the desired fluid therapy supplement or medication Lift up the Syringe Securing Knob and rotate towards the right 90 Place the syringe into the bed Be sure to insert the nozzle into the syringe slot Then press and hold the secure button on the driver to bring the driver block into such a position that the extremity of the syringe plunger can be placed into the driver slot Turn the Securing Knob to the left 90 and secure the syringe 2 The ON OFF switch at the left side of the pump is a power switch Connect the power cable to a wall outlet and turn the pump on Press and hold the PURGE button to purge the syringe and the set tubing 3 Press the SET TIME button to preset the desired infusion time while the light green indicates a corresponding number is on 4 Press the RUN STOP button to start infusion the running green light will be on During the infusion the SET TIME and RAPID buttons are locked f you need to 5 adjust the infusion time setting press RUN STOP follow
3. ed by SET TIME button to reset the infusion time To continue operation press RUN STOP again 5 During the infusion when RUN STOP is pressed the pump stops operation and goes into a HOLD mode with Operation Indicator green on To continue the rest of infusion with the original setting simply press RUN STOP again NOTE a If there is an adjustment on the syringe or a resetting of the infusion time the pump will begin infusion with the new settings Otherwise when RUN STOP is pressed the pump will continue the rest of infusion with the original settings b If the syringe or the set tubing becomes occluded beyond the pump s capability to pump the alarm will activate and the OCCLUSION indicator red will come on The pump will stop operating C To remove the syringe lift up the Syringe Securing Knob and rotate right 90 The RUN indicator goes off when the syringe is removed Storage This product should be stored in an environment with ambient temperature range of 14 F 131 F 10 C 55 C relative humidity below 93 and air pressure 500hpa 1060hpa Do not store close to corrosive vapour and or harmful impurities LIMITED WARRANTY The Syringe Pump has been carefully manufactured from the highest quality components The pump is guaranteed against defects in material and workmanship for two 2 years from date of purchase by the original purchaser Manufacturer s obligation or that of its designated represe
4. ight 4 4 lbs 2 kg Operating Temperature 41 F 104 F 5 40 C This Micro Infusion Syringe Pump uses a propulsive force to inject medication and desired fluids into the patient Among the features provided by this pump are e Audible and Visual Alarms of Near Empty Complete Occlusion and Low Batt e Wide range of compatible syringe 20ml 50 60ml 100ml e Waterproof ergonomic touch control panel Keypad Description A Control Panel AC power indicator Built in battery indicator Near end alarm COMPLETE OCCLUSION alarm SET TIME indicator SET TIME button PURGE RUN STOP Syringe driver head Syringe securing bar B Keypad Description SET TIME activated only in STOP mode When pressed sets the desired infusion time SET TI AE indicator should illuminate PURGE Only functions in STOP mode When pressed starts pursing tubing set RUN ZSTOP Press to start or stop the pump MODE indicator should illuminate Alarms and Indicator Lights NEAR END When there is approximately one minute of infusion time remaining this indicator flashes and the alarm buzzer sounds To silence the alarm press the RUN ZSTOP button COMPLETESOCCLUSION When infusion is complete the indicator is illuminated in red and the alarm buzzer sounds COMPLETE oO oO when the device senses an occlusion by not being able to drive with a force of CCLUSI N 6 5kg 1Ks the indicator
5. ntative under this Limited Warranty shall be limited at our option to repairing or replacing the pump which upon examination is found to be defective in material or workmanship The repair of replacement of any product under this Limited Warranty shall not extend the above mentioned Warranty period All repairs under this Limited Warranty should be undertaken only by qualified trained service personnel In the event that a pump is found to be defective during the warranty period the purchaser shall notify manufacturer or its designated representative within thirty 30 days after such defect is discovered The defective pump should be sent immediately to manufacturer or its designated representative for inspection repair or replacement Material returned should be properly packaged to avoid severe pump damage This Limited Warranty shall not apply to defects or damage caused wholly or in part by negligence spilt fluids dropping of the pump misuse abuse improper installation or alteration by anyone other than qualified trained personnel or to damage resulting from inadequate packaging in returning the pump This Limited Warranty is the sole and entire warranty pertaining to manufacturer s products and is in lieu of and excludes all other warranties of any nature whatsoever whether stated or implied or arising by operation of law trade usage or course of dealing including buy not limited to warranties of merchantability and
6. used for intravenous arterial infusion anesthetic injection IV antibiotics etc This syringe pump offers a reliable alternative for fluid control especially suitable for short term high speed thick fluid and precise injections Precautions SAVE THIS MANUAL FOR YOUR FUTURE REFRENCE WARNINGS e DO NOT USE A PUMP SYRINGE OR ACCESSORY THAT SHOWS ANY SIGN OF DAMAGE e ONLY AUTHORIZED SERVICE PERSONNEL SHOULD REPAIR THIS PUMP MANUFACTURER ASSUMES NO RESPONSIBILITY FOR INCIDENTS THAT OCCUR IF THE PUMP IS NOT REPAIRED ACCORDING TO MANUFACTURER AUTHORIZED PROCEDURES e BEFORE CONNECTING THE SYRINGE TO THE PATIENT USER MUST PRIME THE SYRINGE AND EXTENSION TUBE TO PREVENT AIR TO THE PATIENT 9 TO CLEAN THE PUMP USE A DAMP NOT WET CLOTH OR SPONGE DO NOT IMMERSE PUMP OR POWER CABLE INTO WATER OR OTHER CLEANING SOLUTIONS e ONLY USE THE THREE PRONGE POWER CORD INCLUDED IN THE PACKAGE TO CONNECT THE PUMP TO AN AC WALL OUTLET e OPERATE AWAY FROM STRONG MAGNETIC FIELD LARGE EQUIPMENT OR BIG MOTOR Specifications Protection Against Electric Shock T BF ype Mode of Operation Continuous Degree of Protection Against Ingress of Fluids Drip Proof IPX1 Acceptable syringe sizes 20ml 50 60 ml 100ml Pre set infusion times 4 8 12 16 and 20 minutes 20 seconds Battery operation at a flow rate of 50 ml hr assuming fully charged battery 4 hours Relative Humidity Power Requirements 120VAC 60Hz 6VA 13 x4 1 2 x A 1 2 We
7. warranties of fitness for a particular purpose Purchaser expressly agrees that the remedies granted to it under this limited warranty are purchaser s sole and exclusive remedies with respect to any claim of the purchaser arising under this Limited Warranty
Download Pdf Manuals
Related Search
Related Contents
鳥インフルエンザ遺伝子検査法の特性と電気泳動による リアルタイム デジトロニック デジタルプログラム調節計 DCP31/32 EMS1122LHG PL92-904Q - Pos. Feed Drill 0706.qxp Samsung HT-ES420K manual de utilizador Cables Direct 20m USB 2.0 Active Repeater Rabot de coupe à angle faible et rabot de coupe standard Troubleshooting the DM-80 Kohler Aegis LV680 User's Manual Copyright © All rights reserved.