Home
CL2X8-D1B2 CC-Link/LT Remote I/O Module User`s Manual
Contents
1. 5 6 7 8 9 Jono External power External power J E tH Yy 1 x1 Coo nwe e T R ZIO b All COM B and DC24B terminals are connected within the module common The power to the module is supplied via the power adapter Toutes les bornes COM B et DC24B sont connect es l int rieur du module commun L alimentation du module se fait via l adaptateur d alimentation External power supply of the input part Alimentation externe de la partie entr e 24V DC 24Vcc Terminal block for I O interface Negative Bornier pour interface E S commun common n gatif External power supply of the input part Alimentation externe de la partie entr e 24V DC 24Vcc Connector for CC Link LT interface Terminal block for I O interface Positive common Insulation Connecteur pour interface CC Link LT Bornier pour interface E S commun positif Isolation 6 External Dimensions A setting error occurs and L ERR LED flickers if the value outside the range 1 to 64 is set _ Example Set the switches as below when setting the station B number to 32 a x Station Ten s place One s place Q number 40 2 fo B 4 R 1 32 OF
2. CL2X8 D1B2 CC Link LT Remote I O Module Thank you very much for purchasing this product Please read this manual thoroughly before starting to use the product and handle the product properly WIRING PRECAUTIONS PRECAUTIONS DE CABLAGE Z CAUTION A AVERTISSEMENT Fix terminal screws securely within the regulated torque Loose terminal screws may cause fire and or malfunction If the terminal screws are too tight it may cause short circuit or erroneous operation due to damage of the screws Make sure foreign objects do not get inside the module such as dirt and wire chips It may cause fire product failure or malfunction Effectuer l installation et le c blage apr s avoir d connect l alimentation externe sur toutes les phases Si l alimentation n a pas t coup e sur toutes les phases il y a risque d lectrocution ou d endommagement du produit PR CAUTIONS DE C BLAGE STARTING AND MAINTENANCE PRECAUTIONS ATTENTION User s Manual MODEL CL2X8 D1B2 U MODELCODE 13JP03 IB NA 0800233 D 1406 MEE 2002 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Read these precautions before using Please read this manual carefully and pay special attention to safety in order to handle this product properly Also pay careful attention to safety and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the user s manual of th
3. Ltd 2nd Floor Tower A amp B Cyber Greens DLF Cyber City DLF Phase lll Gurgaon 122002 Haryana India Tel 91 124 463 0300 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road PO BOX11 Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 A MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Australia When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice
4. WARRANTY Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 USA Tel 1 847 478 2100 Brazil MELCO TEC Representacao Comercial e Assessoria Tecnica Ltda Av Paulista 1439 cj74 Bela Vista Sao Paulo CEP 01311 200 SP Brazil Tel 55 11 3146 2200 Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen Germany Tel 49 2102 486 0 UK Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB UK Tel 44 1707 27 6100 Italy Mitsubishi Electric Europe B V Italian Branch Viale Colleoni 7 20864 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 AC 420 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 Mitsubishi Electric Europe B V o s Czech office Avenir Business Park Radicka 751 113e 158 00 Praha5 Czech Republic Tel 420 251
5. 4 1kV Num ros de broche et noms des signaux Num ros de borne et noms des signaux 4321 coon Withstand voltage 500V AC for 1 minute between primary external DC terminal and secondary internal circuit 10MQ or more between primary external DC terminal and secondary internal circuit when measured with a 500V DC insulation resistance tester Insulation resistance Protection class IP2X Weight 0 09kg I O part connection method Direct type 14 point terminal block M3 screw M thode de raccordement de Bornier 14 points type direct Vis M3 la partie E S Module installation method DIN rail installation mounted by screws of type M4 x 0 7 mm x 16 mm or larger Can be installed in six directions Applicable solderless RAV1 25 3 terminal in conformance with JIS Borne sans soudure a utiliser C 2805 e V1 25 3 Japan Solderless Terminal Mfg Co Ltd 1 25 3 TG1 25 3 Applicable wire size 0 3 to 1 25mm 22 to 16 AWG stranded wire Taille du fil a utiliser NICHIFU TERMINAL 2 INDUSTRIES Co Ltd bea Teawa i RAV1 25 3 L en conformit avec JIS torsad C 2805 V1 25 3 Japan Solderless Terminal Mfg Co Ltd 1 25 3 TG1 25 3 Nichifu Terminal Industries Co Ltd Wire Material Copper Fil Mat riau Cuivre Temperature 75 C or more rating 75 C ou plus Gamme de temp rature 1 For applicable solderless terminals connect
6. 551 470 Mitsubishi Electric Europe B V Polish Branch ul Krakowska 50 32 083 Balice Poland Tel 48 12 630 47 00 Russia Mitsubishi Electric Europe B V Russian Branch St Petersburg office Piskarevsky pr 2 bld 2 lit Sch BC Benua office 720 195027 St Petersburg Russia Tel 7 812 633 3497 CBI Electric Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 977 0770 China Mitsubishi Electric Automation China Ltd No 1386 Hongqiao Road Mitsubishi Electric Automation Center Changning District Shanghai China Tel 86 21 2322 3030 France Czech Republic Poland South Africa Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wugong 3rd Road Wugu District New Taipei City 24889 Taiwan R O C Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 3F 1480 6 Gayang Dong Gangseo Gu Seoul 157 200 Korea Tel 82 2 3660 9530 Singapore Mitsubishi Electric Asia Pte Ltd Industrial Division 307 Alexandra Road Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2308 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Soi Serithai 54 T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2906 3238 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Indonesia Tel 62 21 663 0833 India Mitsubishi Electric India Pvt
7. programme s quentiel un circuit de verrouillage sur la base des informations d tat de la communication de fa on maintenir la s curit de fonctionnement du syst me dans l ventualit d un probl me de communication affectant la liaison de donn es Faute de quoi une sortie erron e ou un dysfonctionnement pourrait tre l origine d accidents L entr e peut tre activ e ou d sactiv e la survenance d un probl me dans les modules E S distants On constituera donc un circuit de surveillance externe couvrant tous les signaux d entr e qui pourraient tre l origine d un accident grave PR CAUTIONS DE CONCEPTION NATTENTION Ne pas grouper ni placer proximit les cables de commande ou c bles de communication avec les c bles des circuits principaux et ou d alimentation C bler en pla ant ces c bles une distance d au moins 100mm 3 94 pouces des c bles des circuits principaux ou de l alimentation Cela pourrait tre l origine d un bruit parasite entra nant des dysfonctionnements PR CAUTIONS D INSTALLATION N ATTENTION Perform installation and wiring after disconnecting the power supply at all phases externally If the power is not disconnected at all phases an electric shock or product damage may result WIRING PRECAUTIONS A CAUTION Terminal screws which are not to be used must be tightened always Otherwise there will be a danger of short circuit against t
8. F JON ON OFF OFF ON OFF 64 2 52 2 4 5 installation hole M4 screw 4 Connector Connector for CC Link LT communication line and module power 4 5 55 5 2 19 0 4 0 02 4 2 10 0 39 for CC supply 0 18 0 16 S Link LT interface a E 5 Terminal Terminal block for connecting input signals and external power ae s ia sS block for I O supply of the input part or amp o 0 16 interface HH Center of z yoj o DIN rail 6 Hook for Hook for installing the module on a DIN rail o par TS DIN rail lel 4 Handling Precautions SY 1 Tighten the terminal screws for the module to the specified torque shown below Insufficient tightening torque could result in shorts failures or malfunction 1 Serrer les vis de borne du module dans les limites du couple de serrage prescrit Un couple de serrage insuffisant peut tre a l origine de court circuits pannes ou dysfonctionnements Module mounting screw M4 screw 0 78 to 1 08 Nem Terminal block terminal screw M3 screw 0 42 to 0 58 Necm Vis de fixation de bornier vis M3 0 42 0 58 Necm 2 When using a DIN rail attach the DIN rail after taking the following items into consideration Applicable DIN rail types conform to JIS C 2812 TH35 7 5Fe TH35 7 5Al Interval between the DIN rail s installation screws Tighten the screws using a pitch of 200mm 7 87in or less when attaching a DIN rail 3 To attach the remote I O module to the DIN rail pr
9. ained in this manual Using this module in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product Do not directly touch the module s conductive parts Doing so could cause malfunction or trouble in the module Tighten the module securely using DIN rail or installation screws within the specified torque range If the screws are too lose the module may drop from its installation position short circuit or malfunction If the screws are too tight the screws may be damaged which may cause the module to drop from its installation position or short circuit WIRING PRECAUTIONS Z WARNING Attire l attention sur le fait qu une n gligence peut cr er une situation de danger avec risque de blessures l g res ou de gravit moyennes ou risque de d g ts mat riels A ATTENTION Dans certaines circonstances le non respect d une pr caution de s curit introduite sous le titre A ATTENTION peut avoir des cons quences graves Les pr cautions de ces deux niveaux doivent tre observ es dans leur int gralit car elles ont trait la s curit des personnes et aussi du syst me Veiller ce que les utilisateurs finaux lisent ce manuel qui doit tre conserv soigneusement port e de main pour s y r f rer autant que de besoin PR CAUTIONS DE CONCEPTION Z AVERTISSEMENT Pr voir dans le
10. e CPU module to use for a description of the programmable controller system safety precautions In this manual the safety precautions are classified into two levels JN WARNING and A CAUTION WARNING Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury Z CAUTION Indicates that incorrect handling may cause hazardous conditions resulting in minor or moderate injury or property damage Under some circumstances failure to observe the precautions given under N CAUTION may lead to serious consequences Observe the precautions of both levels because they are important for personal and system safety Make sure that the end users read this manual and then keep the manual in a safe place for future reference DESIGN PRECAUTIONS A WARNING Do not touch terminals when the power is on It may cause an electric shock or malfunction Perform cleaning the module or retightening of terminal screws after turning off the all external power supply for sure Failure to do so may cause failure or malfunction of the modules DESIGN PRECAUTIONS A CAUTION Do not disassemble or modify the module Doing so may cause failure malfunction injury or fire The module case is made of resin do not drop it or subject it to strong shock A module damage may result Make sure to switch all phases of the external power supply off before installing or remo
11. ed to the terminal block refer to the table above Use applicable wires for the solderless terminals and fix them with an appropriate tightening torque Use UL listed solderless terminals and for crimping use a tool recommended by their manufacturer 1 Quant aux bornes sans soudure a utiliser pour les raccordements sur la plaque bornes voir le tableau ci dessus Utiliser les fils du type prescrit pour les bornes sans soudure et serrer un couple de serrage appropri Utiliser les bornes sans soudure r pertori es par UL et pour le montage utiliser l outil recommand par le fabricant de ces bornes 3 Part Names This section explains the names of the components for the remote I O module 1 HELSEG CL2x8 D1B2y_ MITSUBISHI C 3 PW L RUNL ERR 01234567 O O O 0000 J onl Anmann i onim a ooog 1 r LINKIPW IN nonno hs zj XO X4 X1 X5 5 x2 X6 X3 X7 6 gt LJ Pin numbers and signal names Terminal numbers and signal names 0o00 LINK PW LINK PW 1 Operating onfirmation details status indicator PW On Power supply on a Off The power supply is turned off or the voltage drop is too large L RUN On Normal communication Off Communication cutoff time expiration error L ERR On Indicates that a com
12. ess the centerline area of the DIN rail hook beneath the module until a click is heard 4 Maintain some distance between the module and other components and parts 10 mm from the top and 60 mm from the bottom of the module in order to improve 51 5 2 03 Operating 0 to 55 C ambient 0a55 C temperature Temp rature ambiante de fonctionnem ent Storage 25 to 75 C ambient temperature Operating 5 to 95 RH non condensing ambient humidity Storage ambient humidity Vibration Compliant Frequenc Constant Half Sweep resistance with JIS B y acceleration amplitude count feo and Under 5 to 84Hz 3 5mm 10 times intermittent 2 each in 8 4 t 9 8m 61131 2 Vibration 150z a X Y Z directions Under 5 to 8 4Hz 1 75mm continuous 8 4to 4 9m vibration 150Hz Shock Compliant with JIS B 3502 and IEC 61131 2 resistance 147 mis2 3 times each in 3 directions X Y Z Operating No corrosive gases atmosphere Operating 0 to 2000m altitude Installation Inside a control panel 3 location Overvoltage Il or less category Pollution 2 or less degree 2 1 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is
13. hall be used in conditions i where any problem fault or failure occurring in the PRODUCT if any shall not lead to any major or serious accident and ii where the backup and fail safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem fault or failure occurring in the PRODUCT The PRODUCT has been designed and manufactured for the purpose of being used in general industries MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY INCLUDING BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT WARRANTY TORT PRODUCT LIABILITY FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS PRECAUTIONS OR WARNING CONTAINED IN MITSUBISHI S USER INSTRUCTION AND OR SAFETY MANUALS TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT Prohibited Application Prohibited Applications include but not limited to the use of the PRODUCT in Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User Aircraft or Aerospace Medical applications Train e
14. he bare solderless terminals Perform correct wiring for the module according to the product s rated voltage and terminal arrangement Connecting to a power supply different from rating or miss wiring may cause fire and or product failure Utiliser le module dans un environnement conforme aux sp cifications g n rales pr sent es dans ce manuel L utilisation de ce module dans un environnement autre que celui pr vu dans les sp cifications g n rales peut tre l origine d un choc lectrique d un d part de feu ou d un dysfonctionnement ou peut endommager ou d t riorer le produit Eviter tout contact direct avec les parties conductrices du module Cela pourrait tre l origine de dysfonctionnements ou autres probl mes avec le module Serrer le module fermement avec un rail DIN ou avec des vis de fixation serr es dans les limites du couple de serrage prescrit Si le serrage des vis est insuffisant il y a risque de chute du module de court circuit ou de dysfonctionnement Un serrage excessif peut endommager les vis et ily a risque de d tachement du module et de court circuit Modulepower Voltage 24V DC 15 to 20 ripple ratio within 5 40mA or lower When 24V DC and all point is on supply Current consumption Noise durability DC type noise voltage 500Vp p noise width 1us noise carrier frequency 25 to 60Hz noise simulator condition First transient noise burst IEC 61000 4
15. munication data error has occurred or the setting switch is outside the allowable range Flicker at regular intervals Indicates that the setting switch has been changed while current is being conducted The module continues to operate even while the LED is flickering The changed settings will be reflected when the power has been restored Flicker at irregular intervals Indicates that the terminal resistor is left unconnected or that the module or connection cable are affected by noise Off Normal communication Oto7 Displays the ON OFF status of the input turned on in the ON status and turned off in the OFF status 2 Response Set the response time OFF gt ON ON gt OFF time of the remote time setting I O module switch OFF is set as default factory set Noise may be taken in as input if high speed response type is set Be sure to set response time in consideration of the environment ON 0 5ms High speed response type OFF 1 5ms Standard type 3 Station Select 10 20 or 40 to set the ten s place of the station number number setting Select 1 2 4 or 8 to set the one s place of the station switches number All switches are set to OFF at shipment from the factory Always set the station number within the range of 1 to 64 Ne pas toucher aux bornes quand l appareil est sous tension Cela pourrait tre a l origine d un choc lectriq
16. quipment transport equipment such as Elevator and Escalator Incineration and Fuel devices Vehicles Manned transportation Equipment for Recreation and Amusement and Safety devices handling of Nuclear or Hazardous Materials or Chemicals Mining and Drilling and or other applications where there is a significant risk of injury to the public or property Notwithstanding the above restrictions Mitsubishi may in its sole discretion authorize use of the PRODUCT in one or more of the Prohibited Applications provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail safe redundant or other safety features which exceed the general specifications of the PRODUCTs are required For details please contact the Mitsubishi representative in your region 2 ventilation and to make replacement of the module easy if a remote I O module is installed on a board 5 Install the remote I O module on a level surface If the surface is uneven unnecessary force is applied to the printed circuit board causing malfunctions 5 Wiring Connector for CC Link LT interface CL2x8 D1B2 Insulation 24V_ OH 1 DA DB perc supply of the Terminal block supply of the 41 246 input part for V O interface input part _ferminal block f 2avDC Negatvecommon 24VDC co DC24A 1 DC24A cr 2 DC24B 2 Dc2a8 i 3 x0 R j 4 COMB _
17. supplied from fixed facilities The surge voltage withstand level for up to the rated voltage of 300V is 2500V 2 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used Pollution level 2 is when only non conductive pollution occurs A temporary conductivity caused by condensing must be expected occasionally 3 It can also be used in an environment other than on the control panel if the conditions such as usage ambient temperature and humidity are satisfied 2 2 Performance specifications The performance specifications for the remote I O module are shown in the following table Number of inputs 8 points Isolation method Photocoupler isolation Rated load voltage 24V DC Rated input current Approx 4mA Max simultaneous ON input 100 points ON voltage ON current 19V or higher 3mA or higher OFF voltage OFF current 11V or lower 1 7mA or lower Input resistance 5 6kQ Response Response 0 5ms High speed 1 5ms Standard type time time setting response type OFF TYP 0 05ms gt ON MaXx 0 1ms 1 5ms ON TYP 0 2ms OFF MAX 0 5ms 1 5ms Common wiring method 8 points 1 common 4 points terminal block 2 wire type Input method Positive common negative common shared type Number of stations occupied In 4 point mode Occupies 2 stations In 8 or 16 point mode Occupies 1 station
18. ue ou d un dysfonctionnement Avant de nettoyer le module ou de resserrer les vis de borne s assurer que toutes les alimentations externes ont effectivement t coup es Faute de quoi il ya risque de panne ou de dysfonctionnement des modules PRECAUTIONS DE DEMARRAGE ET DE MAINTENANCE Z ATTENTION Ne pas d monter ni modifier le module Cela pourrait tre a l origine de pannes de dysfonctionnements de blessures ou d un d part de feu Ne pas faire tomber ou soumettre le module a des chocs car son bo tier en plastique est fragile Il pourrait en r sulter un endommagement du module Avant d installer le module dans le tableau ou de l en retirer il est indispensable de couper l alimentation externe sur toutes les phases Faute de quoi il y a risque de panne ou de dysfonctionnement des modules PRECAUTIONS DE MISE AU REBUT Z ATTENTION Lors de sa mise au rebut ce produit doit tre trait comme un d chet industriel 1 Overview This user s manual explains specifications and names of individual parts of the CL2X8 D1B2 type CC Link LT remote I O module hereinafter abbreviated as remote I O module 2 Specifications 2 1 General Specifications The General specifications for the remote I O module are shown in the following table CONDITIONS OF USE FOR THE PRODUCT 1 Mitsubishi programmable controller the PRODUCT s
19. utiliser le produit correctement Ces pr cautions ne concernent que l quipement Mitsubishi Dans le manuel de l utilisateur du module CPU correspondant voir l expos des pr cautions de s curit concernant le syst me de l automate programmable Dans ce manuel les pr cautions de s curit sont class es en deux niveaux savoir N AVERTISSEMENT et A ATTENTION A AVERTISSEMENT Attire l attention sur le fait qu une n gligence peut cr er une situation de danger avec risque de mort ou de blessures graves A WARNING Configure an interlock circuit in a sequence program so that the system operates on the safety side using the communication status information in the event the data link falls into a communication problem Otherwise erroneous output and malfunction may result in accidents Input could be switched on or off when a problem occurs in the remote I O modules So build an external monitoring circuit that will monitor any input signals that could cause a serious accident DESIGN PRECAUTIONS A CAUTION Do not have control cables and communication cables bundled with or placed near by the main circuit and or power cables Wire those cables at least 100mm 3 94 inch away from the main circuit and or power cables It may cause malfunction due to noise interference INSTALLATION PRECAUTIONS A CAUTION Use the module in an environment that meets the general specifications cont
20. ving the module to from the panel Failure to do so may cause failure or malfunction of the modules Les vis des bornes qui restent inutilis es doivent toujours tre serr es Faute de quoi il y a danger de court circuit par contact avec les bornes barres sans soudure Effectuer le c blage du module correctement compte tenu de la tension nominale du produit et en respectant l affectation des bornes Le raccordement d une alimentation de tension nominale diff rente ou une erreur de c blage peuvent tre a l origine d un d part de feu et ou d une panne du produit Fixer les vis de borne fermement en serrant au couple prescrit Des vis de bornes desserr es peuvent tre a l origine d un d part de feu et ou de dysfonctionnements Si serrage excessif des vis de bornes peut les endommager et tre a l origine d un court circuit ou d un fonctionnement erratique Veiller a viter toute p n tration d impuret s copeaux de c blage ou autre corps tranger dans le module Cela pourrait tre l origine d un d part de feu ou du panne ou d un dysfonctionnement du produit PRECAUTIONS DE DEMARRAGE ET DE MAINTENANCE N AVERTISSEMENT DISPOSAL PRECAUTIONS Z CAUTION When disposing of this product treat it as industrial waste PRECAUTIONS DE SECURITE Lire ces pr cautions avant usage Pri re de lire attentivement ce manuel Pr ter une attention particuli re a tout ce qui a trait la s curit pour
Download Pdf Manuals
Related Search
Related Contents
再スキャンの方法はこちら Advertencia Operaciones Preparativos Philips 046677416331 energy-saving lamp Sterling Sterlco M-6410 User's Manual Tapage_02_1213_V1 Sony Walkman WM-FX479 User's Manual Copyright © All rights reserved.