Home
Display Station 2020 User`s Guide, GFK-1543C
Contents
1. esses eene eene nn nn enhn nennen enne A 1 Functional Specifications esses eene nn nn A 2 Filter Pads vic ai acid adidas A 4 Contents vii Chapter 1 GFK 1543C Display Station 2020 Features The Display Station 2020 is a high performance workstation designed primarily for use as a hardware platform for Human Machine Interface HMI and Supervisory Control and Data Acquisition SCADA software packages running under either Windows 95 or Windows NT operating systems Each model in the Display Station 2020 family is a fully self contained PC compatible computer with a built in flat screen display and resistive touch screen housed in an industrial IP65 rated front panel mounted unit weighing less than 16 kg 35 28 lbs The unit is housed in a rugged metal case to protect the system against dust water and damage The enclosure provides front panel access to peripherals such as CD ROM floppy drive PS 2 connector and parallel ports Display Stations are available with autoranging main power input unit for 115 230 VAC operation The unit is supplied completely assembled and requires only mounting and connecting The use of special clips to secure the unit to the panel eliminates the need for mounting holes and requires only one cut out to mount the unit Before powering up your system for the first time you should refer to the procedures in Chapte 2 which contains information you need to set up t
2. with FN Key Held with FN Held Sl Start Button E02F M 324D WinMenu Note 2 F CTRL F1 5E00 314E CTRL F4 13 N F14 CTRL F2 5F00 O 184F F15 CTRL F3 6000 P 1950 CTRL F8 CTRL F9 S2 Context Menu Note 3 Unnamed Upper Left 2nd from top left left center 2nd from bottom left Unnamed Lower Left Shift F1 Shift F2 Shift F3 Shift F4 Shift F5 Unnamed Upper Right Shift F6 2nd from top right right center Shift F7 Shift F8 2nd from bottom right Unnamed Lower Right Shift F9 Shift F10 Chapter 5 System Operation 5D00 5 7 Table 5 1 Notes 1 The FN key produces no scan codes on its own but modifies the scan codes produced by the other keys as indicated in the table above 2 The S1 key produces the same scan code as that for a Microsoft Win95 98 compatible keyboard It performs the same function selecting the Windows Start icon 3 The S2 key produces the same scan code as that for a Microsoft Win95 98 compatible keyboard It performs the same function as clicking the left mouse button to produce a popup menu Control and Status Functions The Display Station 2020 includes a control status panel located by the right hand key lock The LEDs and keys on this small membrane panel have the following functions Controls and Indicators Callout is Function Controls the Backlight Mode of operation EA
3. Click Close for the Welcome to Windows 95 window Display Station 2020 User s Guide July 2000 GFK 1543C Setting Up Windows NT Systems Before you get started you need a PS2 keyboard A PS2 mouse is recommended to help navigate through the setup screens Plug in the keyboard PS2 mouse if available and power cord Power on the unit Read license agreement TAB to your choice and press ENTER Type your name Press the TAB key and type your company name Press ENTER RA O es Oe br es Enter your Windows NT Authentication number found on your Windows NT manual You will need to use the TAB key to get to each number field If correct press ENTER Note Computer names must be less than or equal to ten characters to run CIMPLICITY HMI software Each computer on a network must have a unique name 9 Enter a Computer name This name should be unique to other computers on the same network Press ENTER Note Your system has been set up to enable autologon Autologon allows the system to boot into Windows NT without your having to use a keyboard to press CTL ALT DEL 10 You will be prompted for a password e To use the autologon feature type admin for the password Press the TAB key and type admin in the Confirm Password box Press ENTER e To skip the password press ENTER e To assign a password type in a password press the TAB key and type the password in the Confirm Password box Press ENTER 11 Press ENT
4. Power input general Powering up2 1 Powerup troubleshooting 7 2 Printing troubleshooting 7 6 R Recovery image 2 9 Registering your CIMPLICITY software 2 5 Reset accidental 7 2 Restoring factory CMOS settings 6 1 Self test diagnostics 7 1 Serial Mouse troubleshooting 7 4 Setting backlight dimming control Setting up Windows NT systems 2 3 Display Station 2020 User s Guide July 2000 Shutting down the computer 2 9 Specifications functional A 2 mechanical Standard features 1 2 System Configuration Verification 7 1 System vols System Test and Initialization 7 1 T Temperature effect on contrast setting 7 3 Timeout period setting Touch Screen 5 9 Touch Screen Driver for Windows 5 9 Troubleshooting communications 7 5 display keyboard 7 4 memory 7 3 MODBUS RTU communications 7 5 network communications PLC CPU connection 7 5 powerup printing serial mouse TSRs 7 3 U Upgrading CPU or RAM 7 7 hard drive 7 7 W Warning audible GFK 1543C
5. Changing the Air Filter Element The filter element should be changed or cleaned every three months or sooner in dusty environments If the air filter is not changed at suitable intervals or if a non approved filter is used the unit may overheat For details of approved filter elements refer to Environmental Specifications in Appendix A The filter element is mounted to the inside of the back plate of the Display Station using one center securing nut When it becomes necessary to change the filter unscrew the center nut and remove the Filter Hold Down plate Removing the rear cover of the unit is not necessary To change the filter 1 To prevent environmental contaminants from entering the unit power down the unit prior to removing the filter 2 Remove the Center Securing screw as shown in the photo below There is no need to remove the rear cover of the CPU 3 Carefully remove the Filter Hold down plate 4 Remove the filter element and replace it with anew one Refer to ordering information on page A 4 of the Appendix to obtain new filters 5 Put the Filter Hold Down Plate in place and secure it to the backplate by tightening the center securing screw o Center Securing nut I WU GFK 1543C Chapter 3 Hardware Installation 3 7 Chapter 4 GFK 1543C Connectors This chapter describes the connector layout on the standard Display Station 2020 Keyboard and data connectors are provided on the prop
6. Controls the flat panel display contrast only applicable for the STN technology Indicates the status of the flat panel display backlight control mode m Indicates IDE drive activity when an IDE device is being read from or written to LED Indicates system power lighted when power is applied LED Provides a general status indicator that can be used by any additional hardware installed on the system QN tA 5 8 Display Station 2020 User s Guide July 2000 GFK 1543C Touch Screen The Display Station 2000 range includes a resistive overlay touch screen on the flat panel display It has a touch resolution of 1024 x 1024 touch points independent of screen size and provides an efficient and reliable method of entering information suitable for HMI and SCADA software packages The screen responds to the touch of your finger with or without a glove The touch screen is connected internally to the COM 2 serial port which allows it to function with SCADA software If you install a card that has settings that conflict with those of the COM 2 serial port you will need to change the card s configuration Touch Screen Driver for Windows SCADA software which runs under Microsoft Windows is supplied with a driver Twdriver to interface with the touch screen surround The integral touch surround of the Display Station is internally connected to COM2 Parameters must be set within the driver so that they match the hardwa
7. Display Settings and set Colors to 65536 Resolution to 800 x 600 Refresh to 60 Hz and Display Type to Chips amp Technologies 65550 Display Station 2020 Windows NT Touch Screen Driver Installation If the Display Station touch screen drivers become corrupt an experienced user can try re installing the drivers and editing the boot ini file by doing the following procedure 1 D E cM Initial driver installation is completed by double clicking NT setup on the touch driver floppy disk Once installed the computer will request that you reboot the system The touch screen will not work until you edit the NTboot ini file in the root directory of Windows NT A suggested procedure follows Open Windows Explorer Clock View and the menu bar and make sure that you are viewing all files Click the C drive to display all files Find the boot folder in your contents and right click Click the Properties option Click the General tab and make sure that all the attributes are unchecked Archive Apply and Read only Once all boxes are unchecked click Apply and then OK to return to Windows Explorer Double click the boot folder Wordpad will display five lines of code GFK 1543C Chapter 2 Powerup and Software Installation 2 7 2 8 8 boot loader timeout 5 Edit the fourth and fifth line of code to be identical to the code shown below default multi 0 disk 0 rdisk 0 partition 1 WINNT Windows NT Workstation Versio
8. Display Station 2020 systems have a single internal 3 5 inch floppy disk drive which is located under the access panel The floppy drive is a standard 3 5 inch 1 inch high unit capable of operating in both low density 720KB unformatted and high density 1 44 MB unformatted modes 5 2 Display Station 2020 User s Guide July 2000 GFK 1543C CD ROM Drive Display Station 2020 systems include an integral CD ROM drive which is located under the front access panel CD ROM Drive Floppy Disk Drive External Keyboard and Mouse An external keyboard and mouse both using PS2 connectors can be attached via the connectors under the front access panel The touch screen and mouse will work simultaneously if the mouse is Microsoft or IBM PS2 compatible If you are installing an optional serial card none of the ports can be configured as COM 2 which conflicts with the touch screen Keyboard Mouse connector GFK 1543C Chapter 5 System Operation 5 3 Graphic System 5 4 Graphics Controller Display Types A dedicated graphics controller card is used in the PC enclosure inserted into a PCI expansion slot on the motherboard to provide the interface for the panel display The following features are supported e Display panel resolutions from VGA 640 x 480 up to XGA 800 x 600 color support being from 512 to true color It is recommended that the Display Station be run in the resolution configured at the factory e
9. Mode You can configure the timeout period so that the backlight stays fully on for a period of between 1 to 30 minutes before dimming To set the timeout period Press and hold the Backlight Control Button for more than 2 seconds The backlight control LED will begin to flash Each flash of this LED indicates that 1 minute has been added to the time out period If the LED is allowed to flash three times for example and the button is then released the backlight will dim after a period of three minutes has elapsed CIMPLICITY Software For detailed software operating instructions refer to the following documentation GFK 1189 CIMPLICITY HMI for Windows NI and Windows 95 98 Important Product Information GFK 1180 CIMPLICITY HMI for Windows NTTM CIMPLICITY HMI for Windows 95 98CIMPLICITY Server for Windows NT Base System User Manual GFK 1181 CIMPLICITY HMI for Windows NT CIMPLICITY HMI for Windows 95 98CIMPLICITY Server for Windows NT Device Communications Manual GFK 1341 CIMPLICITY HMI HMI for CNC operation manual GFK 1396 CIMPLICITY HMI for Windows NT and Windows 95 98 CimEdit Operation Manual More information can be found at www cimplicity com GFK 1543C Chapter 5 System Operation 5 11 Communications For information on the hardware setup for device communications refer to CIMPLICITY HMI for Windows NT CIMPLICITY HMI for Windows 95 98CIMPLICITY Server for Windows NI Device Commu
10. clamped into place using a clamping bracket with screws adjustable to the height of the card Network Interface The Display Station includes an autosensing 10 100 Ethernet adapter that provides a RJ 45 connector for unshielded twisted pair cable Application Software Display Stations 2020 are supplied with CIMPLICITY HMI software which is preloaded before shipment of the Display Station Demo software only for IC850PCT300 Display Station 2020 User s Guide July 2000 GFK 1543C Chapter Powerup and Software Installation 2 This chapter contains information you need to set up your Display Station s operating system and network communications For details on Windows 95 systems refer to page 2 2 For details on Windows NT systems refer to page 2 3 Initial Startup When you first power up your system you will need to attach a standard PS2 type keyboard to the external keyboard port on the Display Station When the system starts up you will be required to enter the Product ID from the Windows 95 or Windows NT Certificate of Authenticity and other data to set up your system Also most configuration activities that you perform on a Display Station system can be more easily completed using a keyboard or may require a keyboard For details on power supply input see Chapter 4 Powering Up the Display Station Unit Do not connect or disconnect external devices such as a printer or a PS2 mouse or keyboard while the unit i
11. loaded clamps are provided for mounting the Display Station to a panel GFK 1543C A 1 A 2 Functional Specifications CPU and Memory Microprocessor Pentium 233MHz minimum User Memory Minimum 64Mbyte Operating System Hard Disk Windows 95 or Windows NT 6 4Gbyte minimum IDE standard 3 5 inch mounting CD ROM Floppy Drive Standard Read only 32x CD ROM drive Supports 3 5 inch 1 44Mb PC format floppy disks PC Backplane ISA bus card slots One card using full length slot Available PCI bus card slots Two cards using half length slots one graphics card and one Ethernet card Not Available Shared slot Total current available for sharing by up to 2 user cards Accommodates one full length or one half length card Not Available with IC752WFB2x4 or IC752SPL006 5VDC 1 2 A approx 12VDC 0 1 A approx 12VDC 0 1 A approx Display Display Variants 12 inch Color TFT SVGA Active Display Area Power Requirements AC Models AC Input Power Rating 12 inch 246 x 184 5 mm 85 to 265 VAC 200W autoranging 85 to 265V 47 to 63Hz 2 4A 115V 2A 230V 1A Contact your local distributor for upgrades Display Station 2020 User s Guide July 2000 GFK 1543C GFK 1543C Ports Parallel Port One LPT1 Serial Ports COM1 external RS232 port Keyboard Port PS2 Mouse Port PS2 Physical Dimensions Physical Ch
12. should begin now The system is now configured with factory CMOS settings GFK 1543C 6 1 e 6 2 CMOS Checksum Error If the CMOS battery has failed the following error messages will be displayed on the screen CMOS checksum error Defaults loaded CMOS battery failed If you see the above message you can still operate the Display Station by pressing the DELETE key and manually setting up the system You will need to set up the computer each time the system is powered up For setup parameters refer to BIOS Settings This battery has a lifetime of up to 10 years under normal operating conditions If the battery failed contact the GE Fanuc Hotline Display Station 2020 User s Guide July 2000 GFK 1543C Chapter Diagnostics and Troubleshooting This chapter consists of Self Test Diagnostics Troubleshooting and Frequently Asked Questions Self Test Diagnostics describes how to respond to errors that could be detected by the automatic self test that is performed each time the Display Station powers up Troubleshooting contains tables of symptoms their possible causes and recommended corrective actions Frequently Asked Questions contains answers to frequently asked questions Self Test Diagnostics The computer automatically performs self test diagnostics each time it is powered up The self test consists of a series of checks that verify correct performance of the computer
13. that you want and click OK 5 To add the TCP IP protocol A Go to the Configuration tab and click the Add button The Select Network Component dialog box will appear B Click the Protocol icon and click Add The Select Network Protocol dialog box will appear C Inthe Manufacturer list select Microsoft In the Protocol list select TCP IP Click OK Change the Address from 10 0 0 1 to a unique address Change the default subnet mask 255 0 0 0 to your subnet mask E Click OK twice 6 When you have finished setting up the Network click OK in the Network dialog box Click Yes to reboot your system now 2 4 Display Station 2020 User s Guide July 2000 GFK 1543C Login Recommendation If you type admin as your Administrator password your Display Station will automatically log on as Administrator Log onto the system as Administrator when you power up the system Doing so eliminates the requirement to log on to CIMPLICITY when you run the CIMPLICITY Demo or any other CIMPLICITY project that includes a user named Administrator All CIMPLICITY projects are configured with an Administrator user by default Registering Your CIMPLICITY Software Not applicable to ICS50PCT300 models Licenses have been loaded for CIMPLICITY HMI Base Trending TCP IP Communications and Series 90 SNP Communications If you purchase additional product options to run on the Display Station it is necessary to contact GE Fanuc to update the system lice
14. w EP up HUN s 6 1 Restoring Factory CMOS Settings eee ee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 6 1 CMOS Checksum Error iie etre e rrt tana sade te In ER FA coud AAA Fee E ERR TRES cidos ada 6 2 Diagnostics and Troubleshooting ceres ee eee eee ee eene eene ee ette tn eese etna 7 1 Self rest a E 7 1 System Test and Initialization EAEE Aa nnnenee enne 7 1 System Configuration Verification cccccesecececcceceeceeeeeeeeceeeceaeaaeneeeneeeeeeaeaaeaees 7 1 Trouble OIEA A e eee eva 7 2 lev Toit NM 7 2 DI EE 7 3 juna IS 7 3 External PSZ MOUSE ire enero teo EE eter ee ee dee Ene Gehe Ee Ty Fen TL Gon 7 4 Keyboard ceo a rare ote stunt teste oie tut MS tees LOMA eit E 7 4 Display Station 2020 User s Guide July 2000 GFK 1543C Appendix A GFK 1543C Contents COMMUNIC ALIONS A A te Se beet eee oe 7 5 PLC CPU Connection ccccscceseassescvensocvosesvncsossasbosevonsocvnteovncvesscossevencovontsosnecovsarosveees 7 5 MODBUS RTU Communications eese eene nnne nennen eintreten sinn 7 5 Network Communications eese eene nennen tener nnne teens sets seres etin ina 7 6 Pritam aida 7 6 Frequently Asked QUESOS ii ds 7 7 Hardware FAO Si A s 17 Software FAOS ii A etie vid ea NV RE 7 7 Technical Data eosceccs uo no ce aeuo ieu e a aas eoe dae aeuo ao Gone ue eaae ao near ao eue ue oo uasa ze iiciaid ASL Mechanical Specifications
15. 020 User s Guide July 2000 GFK 1543C Connector Layout External devices printer external disk drive etc should not be powered up Remote Video RJ 45 Comi Side Panel Connectors Printer Port LPT1 Keyboard Mouse Front Panel Connectors GFK 1543C Chapter 4 Connectors 4 3 System I O The Display Station 2020 provides the following I O interface channels A single serial interface port is provided by the processor motherboard It uses a standard 9 pin D type connector A single enhanced parallel port is also provided by the motherboard This port is accessible at the front of the unit under the access panel If the end application requires serial or parallel interfaces in addition to those provided by the standard system these can be provided by the addition of specific ISA or PCI I O cards A wide selection of ISA or PCI cards is available from 3 party sources to provide user flexibility Dual channel RS232 asynchronous adapter Dual channel RS422 485 asynchronous adapter Printer port output input adapter Printer Port LPT1 A 25 pin D type female connector mounted under the access panel of the Display Station is used for the printer port Assignment Assignment Strobe 10 Data Bit 0 Acknowledge Busy Data Bit 1 Data Bit 2 Paper End Select Out Auto Feed XT Error Data Bit 3 Data Bit 4 Initialize Printer Data Bit 5 16 Data Bit 6 17 Select In from Printe
16. Anexternal CRT interface using 15 pin high density D type connector Note that the remote video output shown below is for diagnostic use only A BIOS mode is necessary before the external port can be made functional Remote Video The standard Display Station 2020 system includes a 12 1 inch color TFT SVGA resolution screen The flat screen display has the following features e High Luminance equal to or greater than 200cd m2 e Wide angle viewing e A built in backlight with a long life backlight tube equal to or greater than 25 000 hrs e Control of the backlight to maximize the tube lifetime See page 5 9 Display Station 2020 User s Guide July 2000 GFK 1543C Operator Interfaces Keypad The Display Station 2020 incorporates an integral keypad e The main keypad returns the same scan codes as a standard PC AT keyboard listed in Table 5 1 e Thelift up panel provides 24 user configurable function keys The lift up panel has two key locks which can be used to lock it in the closed position e Ifan external PC AT keyboard is connected the integral keypads remain functional It is not necessary to reboot the Display Station when you plug in an external keyboard e The membrane keys located along the sides of the display are the same as function keys F1 through F10 plus the left Control key Main Keypad Membrane Keys Shift F1 through Shift F5 hift F6 hrough Shift F10 Lift up Panel GFK 1543C Chap
17. CIMPLICITY HMI for Windows NT M CIMPLICITY HMI for Windows 95 CIMPLICITY Server for Windows NT Base System User Manual CIMPLICITY HMI for Windows NT M CIMPLICITY HMI for Windows 95 CIMPLICITY Server for Windows NT M Device Communications Manual CIMPLICITY HMI for Windows NT and Windows 95 CimEdit Operation Manual CIMPLICITY HMI HMI for CNC operation manual iii Chapter 1 Chapter 2 Chapter 3 GFK 1543C Contents Display Station 2020 Feat r s eter rare er e nto tia ene oaa ente tissesnevecsvoneievsenteesete 1 1 Feat re Summalty i yere e ee e ia disci stent sates Ed 1 2 Display Station Features eie ie eec t eie i e e E e ee e eo 1 2 Optional Features cete bett ete pered el sted ebbe ceca txt bed Hed ed NNS 1 3 Access Panel etit e ie t i anten eode deae ne e ete eon eot e diga 1 3 NAUES 1 3 Standard I O califa 1 3 ISA and PCT Card Expansion ec o 1 4 Network Interface de EE d e ee erede ee dee e eee ee 1 4 Application Software ccsssssssssssssesssseeeeeeeee eene ene emen em emen em emen em mem emen em emen eene ene 1 4 Powerup and Software Installation eese eee e eee eee eee ee eee ene e eaae 2 1 Initial Startup x iiec e Et UE at ei do ee ina uec o te tu oue Pen inta 2 1 Powering Up the Display Station Unit esssssseseeeeeeeeeene e 2 1 Setting Up Windows 95 Systems WFB203 WFB253 Models 2 2 Setting Up Windows NT
18. ER to continue with Windows NT Setup 12 Click Finish Note With Windows NT it is highly recommended that you create an Emergency Repair Disk once you have completed the setup of your system Go to Start Run Rdisk exe You will need to update this disk anytime you make a change to the hardware or software GFK 1543C Chapter 2 Powerup and Software Installation 2 3 Configuring the Display Station to Run on a Microsoft Network Before setting up your new Display Station for the network you should consult with your network administrator Duplicate TCP IP addresses and duplicate computer names on the same network can cause network problems 1 Click the Start icon then click Settings and Control Panel 2 Inthe Control Panel window double click the Network icon The Network dialog box will appear 3 In the Network dialog box click the Identification tab You will need to type in your Computer name Workgroup name and Computer Description Note Computer names must be less than or equal to ten characters to run CIMPLICITY software Each computer on a network must have a unique name In Windows 95 systems for Viewers and HMIs to be able to browse remote nodes the local computer name must be entered into the WINDOWS 000 HOSTS file 4 To allow sharing A Go to the Configuration tab and click the File and Print Sharing button The File and Print Sharing dialog box will appear B Check the File and Print Sharing options
19. FANUC GE Fanuc Automation Operator Interface Products Display Station 2020 User s Guide GFK 1543C July 2000 GFL 002 Warnings Cautions and Notes as Used in this Publication Warning notices are used in this publication to emphasize that hazardous voltages currents temperatures or other conditions that could cause personal injury exist in this equipment or may be associated with its use In situations where inattention could cause either personal injury or damage to equipment a Warning notice is used Caution notices are used where equipment might be damaged if care is not taken Note Notes merely call attention to information that is especially significant to understanding and operating the equipment This document is based on information available at the time of its publication While efforts have been made to be accurate the information contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or maintenance Features may be described herein which are not present in all hardware and software systems GE Fanuc Automation assumes no obligation of notice to holders of this document with respect to changes subsequently made GE Fanuc Automation makes no representation or warranty expressed implied or statutory with respect to and assumes no responsibility for the accuracy completeness su
20. Systems 0ooooococococonononononononononononononononono hen 2 3 Configuring the Display Station to Run on a Microsoft Network 2 4 Login Recommendation conoci 2 5 Registering Your CIMPLICITY Software eee eeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeees 2 5 Installing Application Software sse 2 6 Directory Str ctre cedet terit tpe potes e entered ner eter opea 2 6 Windows NT Systems acs ie dee ee Ate 2 6 Windows 95 Systetns 5 eee dE Ed Pe ek AR el 2 6 Reloading Windows NT on the Hard Disk From CD see 2 7 Display Station 2020 Windows NT Touch Screen Driver Installation 2 7 Tima ge RECOV Y enis EE 2 9 Instructions for Image Recovery eee cece eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeseseeeeeeeeeees 2 9 Shutting Down the Computer cesses hne 2 9 Hardware Installation snscccssisissssscsscusvssvescenasssssnussviasshasnssevsanvosospispsssevsienitonasvesooess 3 1 Mounting Guidelines n vignette nid Re e eee tiene e e ede ee ts 3 1 Mounting Procedure eee iieii iinne iaei ia aisa iea iene in 3 2 Installing Expansion Cards sss emen ememem em emen emen 3 3 Blankine Plates eint e a ER A A er HER e e E gg 3 5 Configuring Expansion Cards Legacy ISA Only sse 3 6 Changing the Air Filter Element eee Ea a DEE Ra E Ea ES 3 7 V Contents Chapter 4 Chapter 5 Chapter 6 Chapter 7 COHUOCLO S PP A iot
21. afe environment e Wear a properly functioning antistatic strap and be sure that you are fully grounded Never touch the card or any components inside the Display Station unless you are wearing an antistatic strap e Any surface upon which you place the unprotected card should be static safe facilitated by antistatic mats if possible e Extra caution should be taken in cold dry weather when static charges can easily build up 3 4 Display Station 2020 User s Guide July 2000 GFK 1543C Blanking Plates Blanking plates are fitted to each unused card position as shown in Figure 3 1 These blanking plates can be removed as necessary in order to install new cards Any empty slots must have a blanking plate fitted otherwise the air flow will not comply with agency requirements Blanking PCI Slots ISA Slots Locking screw Internal View of Display Station GFK 1543C Chapter 3 Hardware Installation 3 5 Configuring Expansion Cards Legacy ISA Only 3 6 For most applications an IRQ or address cannot be shared by more than one resource If more than one resource is set to the same interrupt or address the application may not respond properly and could cause your machine to lock up Following these instructions when installing Legacy ISA cards will prevent problems with resource conflicts Legacy ISA cards are the oldest standard and require memory I O and IRQ settings to be manually set on the card using jumpers DIP switc
22. and re installed the Service Pack will need to be run after installation Path is CASPA4N386N5P41386 5 12 Display Station 2020 User s Guide July 2000 GFK 1543C Chapter BIOS Settings 6 It is normally not necessary to change the hardware configuration settings in the CMOS memory If settings become corrupt follow the procedures here to reload the factory configuration Restoring Factory CMOS Settings Connect a keyboard and turn on the power Enter the Setup mode by pressing the DEL key when prompted during the computer power up sequence A screen will appear offering several options for changing settings restoring default settings and other functions Follow these instructions to restore the factory configuration 1 Select the Load Setup Defaults option Then select the Save CMOS settings option You will be prompted to exit Do not exit at this time 2 Go into Standard CMOS Setup and make the following selections Type Mode Primary HDD master AUTO AUTO Primary HDD slave AUTO AUTO Secondary HDD master AUTO AUTO Secondary HDD slave AUTO AUTO Drive A 1 44 MB 3 5 drive Drive B NONE Halt on Errors All Faults Note if the Display Station does not have an integral membrane keyboard this should be set to Ignore Keyboard error Exit Standard CMOS Setup 3 Go into Integrated Peripherals Setup Set parallel port to ECP EPP 4 Select Save and Exit Setup The startup sequence
23. aracteristics Panel Cutout 402mm wide 15 8 inches 319mm high 12 6 inches 200mm deep 7 9 inches Width 382mm 15 0 inches Height 299mm 11 8 inches Weight base unit with no optional cards installed 15 6Kg 34 31bs Appendix A Technical Data A 3 A 4 Filter Pads Dimensions Material Performance Requirements 80mm by 80mm P15 150B Retain 75 by weight of dust particles down to 5 10 microns in size Withstand temperatures to 100 C Provide flame resistance to BS5588 and DIN53438 Note Filter pads reference FP80T are available from PAPST MOTOREN GmbH amp Co KG Hermann Papst Strafe 1 78112 St Georgen Schwarzwald Postfach 14 35 Tel 0 77 24 81 0 Fax 0 77 24 81 309 http www papst de home html Display Station 2020 User s Guide July 2000 GFK 1543C GFK 1543C A Access panel 1 Air filter elemen 3 7 Air flow 3 1 Air fo SEM oed 1 4 Audible w ES o Autologon 2 3 2 3 BIOS settings 6 1 Blanking plates 3 5 Cards installation Catalog numbers Display Station IC752CTD450 1 2 CD ROM drive 5 3 CIMPLICITY software operation 5 11 CMOS Battery 6 2 CMOS checksum error 6 2 CMOS settings tl self test diagnostics 7 1 COM1 COM2 eatin pinout 4 5 Communications 5 17 troubleshooting Configuring the N ment Windows Ld 2 4 Connectors 4 1 Control and status functions Controls and i
24. asaate cavesestsaveccesageeees 4 1 NA RN 4 2 Connector La timas linen E er th e aaa a aa 4 3 SISMO sirio iio T 4 4 Printer Port CRET Ia eiretar aaa O cias 4 4 Serial Communication Cables essere enhn nen enses rne enis 4 5 System CDOT ACEO P co vasivdieesccvncconauousenncuspdecsatenssonccep cartes 5 1 System Peripherals x 1o e e i de eere dida 5 2 H rd B ON CE 5 2 Ign dbi qb M Em 5 2 CD ROM Drive iet n HER t eme eee 5 3 External Keyboard and Mouse seen emen emem enemies 5 3 Graphic System ne aie i A a ei diio i tei da 5 4 Graphics Controller iiie deidad teet rei del Ee ed ese 5 4 Display Types ccs ueterem t te tec ee tette ag 5 4 Operator Interfaces eet t rie ree Re ep eleg cete tee e revo recte et ta 5 5 Keypad erga as cedi enema 5 5 Control and Status Functions eina a E EEE nennt etes eerte ee 5 8 TOUCH SCREEN A A detis edo Econ da 5 9 Touch Screen Driver for Windows cccocoooconccnccccnnnononnnnoncnnnnnnnnnnnnnnncccnnnnnnnnnnnininess 5 9 Touch Screen Calibration Procedure eesssseeseseeeeeenemenene 5 9 Setting the Backlight Dimming Control eee 5 10 Dimming Control Settings mini id 5 10 Setting the Timeout Period for Timed Mode eere 5 11 GIMPLICITY Sot WE ut et S ARAS RAN eR IH RE e aes 5 11 Communications aesan es See e deese E e Fede Sete Feet ese We eee oed San dann AR ee quo uo 5 12 BIOS Set ngs usos auo ENS GU TO RS IM
25. ble Causes Solution Display Station does not power up Display is blank PWR indicator is lighted Power not on PWR indicator is not lit or display completely dark See Display on page 7 3 Make sure that Display Station is plugged in Make sure that power source is functioning properly See Display on page 7 3 Non System disk or disk error message displayed Disk in floppy disk drive Remove floppy disk and then reboot or cycle power Safe Recovery Error message displayed Memory count during powerup self test is incorrect CMOS checksum error Defaults loaded CMOS battery failed message displayed A screen appears just after powerup or just after reset which has the title CMOS Setup Utility Occurs on initial power up if the unit is accidentally turned off without first shutting down the Windows 95 software Optional SIMM is installed incorrectly or is incompatible with the Display Station CPU CMOS battery failure The DEL key has been accidentally pressed The Display Station will power up normally Make sure that the appropriate memory is installed correctly Note This battery has a lifetime of up to 10 years under normal operating conditions For more information see CMOS Checksum Error in Chapter 6 Cycle power again The Display Station will power up normally The Display Station reset even though the power was not int
26. dware Installation This chapter describes the procedures for the safe location and securing of the Display Station 2020 The Display Stations have been designed to ensure simple installation of the system A single cut out in the mounting panel is all that is required when mounting the Display Station No extra mounting holes are needed Instead ten spring loaded clips are supplied and are used to secure the unit from behind the mounting panel This chapter also describes how to install ISA and PCI cards and how to change the air filter Mounting Guidelines GFK 1543C Note The IP65 rating applies to the front panel of the Display Station only and not to the rear of the unit In order to meet the European EMC requirements for ESD EN 61000 4 2 of 4 0kV the unit must be installed in a grounded metal enclosure when used in conjunction with the DeviceNet PCI ISA expansion card PC752DVM000 e Jn an industrial environment the panel into which the unit is mounted should provide protection from dust dirt and water e The front access panel must be closed and locked for IP65 protection e The panel should be capable of supporting the weight of the Display Station without distortion to the panel The mounting clips will support a panel thickness of up to 10mm 0 39 inch e All ten of the mounting clips must be fitted properly to achieve a good seal between the Display Station and the panel to which it is mounted e Inlets and
27. e factory configuration Instructions for Image Recovery 1 Prior to Image Recovery a standard PS 2 type keyboard will need to be connected to the external keyboard port Insert the Field Image Recovery Disk into the Floppy Drive After inserting the Recovery Disk the system will prompt you to restore the image Select lt 1 gt to RESTORE SYSTEM TO ORIGINAL CONDITION If you have initiated this process in error press lt 2 gt and Exit the Recovery program Select lt 1 gt again to PROCEED WITH SOFTWARE RESTORE Choose 2 to cancel Recovery and exit to MS DOS At this point the factory image will be recovered from a hidden partition on the Hard Drive This will take approximately 12 minutes When prompted reboot your system After rebooting your unit the system will bring you to the initial startup screens as received from the factory Refer to the Display Station User s Guide for Microsoft set up Network configuration and CIMPLICITY HMI initialization If you have any questions about this procedure please contact 1 800 GE FANUC 9 MS DOS is a registered trademark of Microsoft Corporation Shutting Down the Computer GFK 1543C To avoid damaging files always shut down Windows software before removing power from your Display Station product To shut down Windows 95 or Windows NT software select Shut Down from the Start menu Chapter 2 Powerup and Software Installation 2 9 Chapter 3 Har
28. eady for use How long is the period that the CIMPLICITY HMI software will run without authorization CIMPLICITY HMI will run for four days after initial load Due to normal delays in shipping and purchasing this four day period will usually have expired by the time the end user receives their unit In such case CIMPLICITY will default to a two hour limit You should go ahead and register your CIMPLICITY software immediately upon start up Chapter 7 Diagnostics and Troubleshooting 7 7 Appendix Technical Data A Mechanical Specifications Front Assembly The Display Station 2020 provides a display screen and a built in operator keypad and access panel The whole of the front panel assembly is engineered to IP65 standards Keypad Two keypads are used a main keypad and the control panel They are manufactured from a chemically resistant polyester All the keys provide tactile feedback Main Chassis The main chassis houses the motherboard which is mounted securely in a vertical plane Plug in boards are mounted in a horizontal plane perpendicular to the front of the Display Station The housing for the card connectors is recessed so that the card interfaces do not protrude beyond the profile of the main housing Rear Cover The rear cover of the unit is fixed to the main chassis so that emissions are minimized The cover can be removed easily without breaking any electrical connections Panel Mounting System Ten spring
29. er to the network is not connected to the network Printer cable is too long Replace the cable unshielded or defective Paper tray is empty Fill the paper tray with paper Set printer to online Correct printer drivers not Install the correct printer driver installed Printer is offline Printer prints garbled information Ensure that the printer cable is connected properly to the computer Cable is not connected properly Run a printer self test Refer to the documentation provided with your printer for instructions If the self test fails the problem is printer specific The printing section of the software documentation and in Windows online Help may also be helpful Problem specific to printer Display Station 2020 User s Guide July 2000 GFK 1543C Frequently Asked Questions Hardware FAQs Software FAQs GFK 1543C How do I upgrade the Display Station RAM or CPU in my Display Station All Display Station products contain at least 64MB RAM and 233 MHz Pentium processor Upgrades are available at time of initial order through the Display Station upgrade package IC752WFB25x All RAM or CPU upgrades outside the factory may invalidate the warranty Contact the Support Hotline at 1 800 GE FANUC for more information How can I get a larger hard drive installed in my Display Station Upgraded hard drives are available only at initial order point If availab
30. errupted The CTRL ALT DEL keys were pressed twice at the same time This should never be done unless you are attempting to reset the Display Station A gt appears instead of software Hard disk error insert system disk message displayed upon startup A system floppy disk is inserted Factory CMOS settings have been corrupted This is a temporary situation that occasionally occurs due to CMOS battery drain Remove disk and cycle power See chapter 6 BIOS Settings to verity that Auto Detect is set in CMOS Settings Also refer to page 41 in the ASUS Motherboard manual Display Station 2020 User s Guide July 2000 GFK 1543C Display Symptom Possible Causes Solution Characters are dim Computer screen is in direct light Change lighting or adjust contrast Display is blank PWR indicator is Screen temperature is outside If Display Station is in direct lit operating range sunlight move it and allow it to cool Display Station is set up for Reboot invalid video mode Windows NT models select VGA Mode Windows 95 models press F8 when Starting Windows 95 appears then select Safe Mode If Windows is now displayed go into Control Panel Display Settings and change settings to the correct video driver and mode Contact GE Fanuc s CIMPLICITY hotline for more information Screen saver is active Touch a key on the keypad Cursor on touch screen does not Touch sc
31. eyboard not plugged into Plug keyboard in keyboard port on Display Station System is busy Press CTRL ALT DELETE to view task list Display Station 2020 User s Guide July 2000 GFK 1543C Communications PLC CPU Connection CIMPLICITY does not The system is attempting to 1 With the PLC powered up and communicate with a PLC that has communicate with a 90 30 PLC connected to the Display Station been autoconfigured using the SNP driver and a establish communication between AUTOCONFIG DEFAULT I O CIMPLICITY project the Display Station and PLC via error the 90 30 SNP driver 2 Using a Hand Held Programmer toggle the Default I O Enable or Disable configuration parameter for the CPU Communications between the Display Station and the PLC will be stopped Communications are stopped when you toggle from Enable to Disable or vice versa 3 Power cycle the PLC Communications between the host COM port not configured in Verify that the COM port is computer and the controller are system configured in the system unsuccessful Cabling between computer and Verify that the cable between the controller computer and the controller is correctly wired Baud rate and parity configured Verify that the baud rate and incorrectly parity on the computer are consistent with those on the controller Wrong address Verify that the slave address is correct MODBUS RTU Communications Communications betwee
32. fficiency or usefulness of the information contained herein No warranties of merchantability or fitness for purpose shall apply The following are trademarks of GE Fanuc Automation North America Inc Alarm Master GEnet Motion Mate Series One CIMPLICITY Genius PowerMotion Series Six CIMPLICITY PowerTRAC Genius PowerTRAC ProLoop Series Three CIMPLICITY 90 ADS Helpmate PROMACRO VersaMax CIMSTAR Logicmaster Series Five VuMaster Field Control Modelmaster Series 90 Workmaster Copyright 1998 2000 GE Fanuc Automation North America Inc All Rights Reserved Content of This Manual Preface This manual describes the features and operation of the following CIMPLICITY Display Station products Catalog Number Description IC752WFB204 1C752WFB254 IC752SPL006 CIMPLICITY HMI for CNC with Windows NT includes High Speed Serial Bus HSSB card 1C752WFB202 1C752WFB252 IC752SPL007 1C752WFB203 1C752WFB253 CIMPLICITY HMI with Windows NT CIMPLICITY HMI with Windows 95 IC850PCT300 Revisions to this Manual CNC Display Station with Windows NT This version of this manual GFK 1543C contains the following changes as compared to the previous version GFK 1543B e Instructions for using the Image Recovery Disk page 2 9 Related Publications GFK 1189 GFK 1180 GFK 1181 GFK 1396 GFK 1341 GFK 1543C CIMPLICITY HMI for Windows NT and Windows 95 Important Product Information
33. hardware When the self test is being performed you will see the message XXXX KB OK displayed on the screen where XXXX is a number that increases until it matches the amount of usable memory System Test and Initialization These routines test and initialize board hardware If the routines encounter an error during the tests you will see an error message on the screen There are two kinds of errors fatal and non fatal If a non fatal error occurs the system can usually continue the boot up sequence Non fatal error messages usually appear on the screen with the following instruction press lt F1 gt to RESUME Write down the message and press the Fl key to continue the bootup sequence System Configuration Verification These routines check the current system configuration against the values stored in the CMOS memory If they don t match the program will generate an error message To correct this condition you will need to run the BIOS setup program and correct the configuration information in memory There are three situations in which you might need to change the CMOS settings 1 You are starting your system for the first time 2 You have changed the hardware attached to your system 3 The CMOS memory had lost power and the configuration information has been erased If this has happened call GE Fanuc s Hotline Support at 1 800 GE Fanuc 800 433 2682 GFK 1543C 7 1 Troubleshooting Powerup 7 2 Symptom Possi
34. he control status panel as with the contrast control Dimming Control Settings Default Setting At power up the backlight control is set to the default setting This gives a time out period of 5 minutes that the backlight stays fully on after which the backlight will dim Mode Setting The backlight can be operated in three modes Timed Mode LED on Full Constant Mode LED off Dim Constant Mode LED off To step the system through the three modes apply single presses of the Backlight Control Button Timed Mode This is the default mode In the Timed Mode you can set the period of time for which the backlight operates at full power When the time set expires the backlight display is reduced to Dim and remains at the dim setting until the next interface input using the touch screen or keypad If the system is powered down when the unit is powered up again the default settings will be in effect You must remake any settings for the control of the backlight Full Constant Mode If the Backlight Control Button is pressed once when the system is operating in Timed Mode the Display Station will operate in Full Constant Mode In this mode the backlight is constantly on Dim Constant Mode Pressing the Backlight Control Button a second time selects the Dim Constant Mode In this mode the backlight displays constantly on the Dim setting Display Station 2020 User s Guide July 2000 GFK 1543C Setting the Timeout Period for Timed
35. he operating system and network communications 1 1 1 2 Feature Summary When you purchase a Display Station system you receive e Display Station industrial computer with CIMPLICITY HMI software and operating system software installed See Standard Features below Demo only for IC850PCT300 e Power cord e Installation hardware e CIMPLICITY software licenses and license agreements not included in IC850PCT300 e Ethernet driver floppy disk and manual e Microsoft Windows documentation software distribution Certificate of Authenticity and license agreement Display Station Features Catalog Number 1C752WFB202 252 DS2020 Windows NT IC752SPL007 IC752WFB204 254 DS2020 Windows NT with High Speed Serial Bus Card HSSB IC752SPL006 IC850PCT300 DS2020 Windows NT with CIMPLICITY HMI for CNC Demo software only 1C752WFB203 253 DS2020 Windows 95 operating system CIMPLICITY HMI software Unlimited Point Count Development and Runtime software Pentium 233 MHz minimum Hard disk 6 4 GB minimum Floppy disk drive 3 5 inch 1 44 Mbyte CD ROM drive 32x speed minimum RAM 64 MB minimum Display Stations allow you to install a maximum of 256MB of DRAM Display Color TFT SVGA 800 x 600 Parallel ports One LPT 1 Serial port One RS 232 Contact your local distributor for upgrades and options Display Station 2020 User s Guide July 2000 GFK 1543C Optional Features The foll
36. hes or a configuration program The card and system need to have the same hardware settings 1 Connect a keyboard turn on the system power and press DEL when prompted to enter the BIOS Setup program Select PNP PCI SETUP If the card requires one or more interrupts go to an IRQ that currently reads USED BY ISA NO ICU and change it to Yes by pressing PAGE DOWN Do not use an IRQ that already reads Yes Do not use an IRQ shown as Used in Windows NT diagnostic resources If the card requires memory space enter the address and amount where Memory Used appears Press ESC to exit this screen and F10 to save and exit Setup When the screen goes blank turn off the power If the card has jumpers or DIP switches set them so that they match the IRQ and memory addresses set in the BIOS Setup Set the I O port settings of the card if any so that they fall within the ranges labeled Available in Table 2 If the card is set up using a configuration program proceed with installation then run the card s configuration program Set the IRQ and memory address settings to be the same as those put into BIOS Setup Set the I O port settings 1f any to a range labeled Available in Table 3 1 Table 3 1 1 0 Port Range Table Display Station 2020 User s Guide July 2000 000 1FF Reserved 200 27F Available 280 2FF Reserved 300 377 Available 378 3DF Reserved 3E0 3EF Available 3F0 3FF Reserved GFK 1543C
37. le a larger hard drive is included as part of the Display Station upgrade package IC752WFB25x All hard drive upgrades outside the factory will invalidate the warranty Contact the Support Hotline at 1 800 GE FANUC for more information What HMI software comes preloaded on the Display Station product Beginning in mid February 1997 all IC752WFB SPL units are preloaded with the full point count version of HMI software You can get either Windows 95 or Windows NT operating system with the development runtime packages All Display Station products come with server packages but can be operated as viewers IC850PCT300 models are available from the factory with a Demo version of CIMPLICITY HMI only See http www gefanuc com hmi for ordering information Will Display Station products with limited CIMPLICITY HMI point counts be offered Some Display Stations are available with limited point count packages Contact your distributor for more information Can I log on to an NT System without typing a password All systems have autologon enable for Administrator with admin lower case as the password To disable the screen logon message refer to the CIMPLICITY Web page at http www cimplicityhmi com appnote logon htm The application note provided at this Web site describes how to create a default logon for the operating system that also acts as a logon for CIMPLICITY so that you only need to turn on the machine to have CIMPLICITY come up and be r
38. n 4 00 operating systems multi 0 disk 0 rdisk 0 partition 1 WINNT Windows NT Workstation Version 4 00 NoSerialMice Com2 multi 0 disk 0 rdisk 0 partition 1 WINNT Windows NT Workstation Version 4 00 VGA mode basevideo sos NoSerialMice Com2 9 10 11 12 13 14 15 16 From the File menu Save then Exit Wordpad Click the Windows NT Start button and select Shut Down Turn the computer off The NT driver will not load properly if you only restart the computer It must be completely powered down Turn the computer on Click the Windows NT Start button select Programs Touch and Touch Screen Control Click the Hardware Controls button and check that COM2 is selected Click the Calibrate button and follow the procedures for calibration Exit the program Display Station 2020 User s Guide July 2000 GFK 1543C Image Recovery The following procedure provides instruction on how to use the Field Image Recovery Disk 44A749863 GOIRxx This disk will enable you to recover all software on your computer as received initially from GE Fanuc Before attempting an Image Recovery on your unit make sure to record all critical settings and conduct a full back up of all CIMPLICITY Projects and critical documents You will also need to have your CIMPLICITY registration and Microsoft Authorization Numbers handy This process will clear all contents from your Hard Drive and return your system to th
39. n the host COM port not configured in Verify that the COM port is computer and the controller are system configured in the system unsuccessful Cabling between computer and Verify that the cable between the controller computer and the controller is correctly wired Baud rate and parity configured Verify that baud rate and parity on incorrectly the computer are consistent with those on the controller MODBUS port not configured for Verify that the controller s RTU communications MODBUS port is configured for RTU communications Wrong address Verify that the slave address is correct GFK 1543C Chapter 7 Diagnostics and Troubleshooting 7 5 7 6 Network Communications Symptom Possible Causes Solution Conflicts on network IP Address not unique Change the IP address to a unique address Contact your system administrator if this or other settings need to be changed Printing Printer will not turn on Cables not connected properly Ensure that the cables are properly Printer power cord not plugged in connected and that the power cord is connected to the electrical outlet Printer will not print Printer is not turned on Turn on the printer Printer is not online Set the printer to online The device drivers for your Install the correct printer drivers application are not installed for your application in Windows Printer that is set up for a network Connect the print
40. ndicators D Diagnostics bootup seq uence 7 1 self test 7 1 system configuration verification system test and initialization 7 1 Dimming control settings Display troubleshooting Index Error messages AUTOCONFIG DEFAULT 1 0 7 5 CMOS checksum error 6 2 7 2 CMOS Setup Laity EA Disk Error Insufficient memory 73 non fatal 7 Non system as Out of Memory 7 3 Safe Recovery 7 2 External keyboard and mouse 533 F Field image recovery disk 2 9 Filter changing Filter pads A 4 Floppy disk drive Frequently asked questions 7 7 G Graphic system 5 4 H Hard disk drive 5 2 l vo 13 Image recovery 2 9 Indicators 5 8 Initial startup Installation cards 3 3 panel mounting 3 1 Installed network components Installing application software 2 6 K Keyboard tr oubieshooting 7 4 Keypad L LEDs 5 8 Legacy ISA cards 3 6 Login recommendation 2 5 LPTI Index 1 Index Index 2 location pinout Memory troubleshooting 7 3 MODBUS RTU communications troubleshooting 7 5 Mounting guidelines 3 1 Mounting procedure 3 2 Network communications setting up for Windows 95 98 2 4 troubleshooting 7 6 Network components Network interface Operator interfaces Optional features 1 3 Panel cutout dimensions 3 2 Peripherals 5 2 PLC CPU connection troubleshooting 7 5
41. nications Manual GFK 1181 Your Display Station has been configured with networking components that enable you to establish new networks or connect to existing networks easily If you intend to use Microsoft NetBEUI TCP IP or Direct Cable Connection some minimal setup changes are required before you can use the system for network applications In both Windows 95 98 and Windows NT systems these settings are changed using the Network application in the Control Panel program group Installed Network Components Network Component Comments PCI Network Adapter Automatically configured in system TCP IP Default settings must be changed before connecting to an existing network Contact your network administrator for appropriate settings NetBEUI Default settings must be changed before connecting to an existing network Contact your network administrator for appropriate settings System Identification Computer Name Each system is uniquely identified by its serial number and can be renamed before adding it to an existing network Workgroup The default workgroup is Workgroup This should be renamed before adding it to an existing network The IP Address must be changed to a unique address If it is not changed conflicts could occur on your network Note On any Display Station product with the HSSB card only use the TCP IP protocol Do not install any other protocols Note For Windows NT systems If any component is removed
42. nsing 1 Click Start Programs CIMPLICITY HMI Registration Click Next for new User Read the License Agreement and select Yes if you agree 2 3 4 Fill in the User Information 5 Click Next 6 Open your CIMPLICTTY software box and find your license packs Open each license pack and type the serial numbers in the fields provided 7 Call the CIMPLICITY phone number that appears on the screen Faxes and phone calls will be processed between 8 AM and 5 PM Eastern time Monday through Friday except for regularly scheduled holidays Faxes and calls received after hours on weekends or holidays will be processed as soon as possible on the following business day When you phone please be prepared to provide GE Fanuc with the following information e Your User information e CIMPLICITY serial numbers e The System Key Code generated during the registration procedure Note When it is installed without the authorization code you can run the software as a fully functional system in two hour increments Your CIMPLICITY software can also be registered over the internet Contact Software Registration at www gefanuc com cimplicity GFK 1543C Chapter 2 Powerup and Software Installation 2 5 Installing Application Software The Windows operating system and CIMPLICITY HMI software are loaded onto the Display Station unit at manufacture If it is necessary to reload software follow the instructions in the documentation supplied with
43. outlets must have at least 25mm of space around them and not be obstructed Adequate airflow around the exterior of the unit is important to the interior temperature of the unit Two fans are used to create air flow through the Display Station ensuring that a correct working temperature is maintained The first of the fans is located within the unit and is used to cool the processor The second fan is built into the power supply housing and blows air out of this unit Incoming air passes through a filter that removes dust and dirt The filter should be checked and replaced regularly For details see page 3 7 3 1 Mounting Procedure Use the following procedure to mount the Display Station 2020 1 Cutan opening in the panel to the dimensions shown The cut out dimensions of 382 x 299mm 15 04 x 11 77 allow a 1 2mm clearance on each edge of the Display Station The unit requires a minimum of 227mm 8 94 depth when mounted 382mm 15 04 299mm 11 77 2 Position the Display Station in the cut out and fit the ten spring loaded retaining clips into the slots on the Display Station All ten clips must be used to produce a good seal Spring Loaded Retaining Clip 3 2 Display Station 2020 User s Guide July 2000 GFK 1543C 3 Screw in the tightening screws on each clip so that the spring is compressed by the nut To ensure a good seal between the Display Station and the mounting panel the clips must be tightened evenl
44. owing features are optional on many models in the Display Station range Contact your GE Fanuc distributor for details e Additional DRAM SIMMs e Higher Speed CPU e CIMPLICITY HMI software license IC850PCT300 only Access Panel A lockable front access panel provides access to the peripheral facilities floppy disk CD ROM drive printer port keyboard and PS2 mouse connectors This panel also incorporates a membrane keypad that provides full keyboard facilities System I O Standard 1 0 The Display Station 2020 provides the following I O interface channels e A single serial interface port is provided by the processor motherboard It uses a standard 9 pin D type connector e A single enhanced parallel port is also provided by the motherboard This port is accessible at the front of the unit under the access panel If the end application requires serial or parallel interfaces in addition to those provided by the standard system these can be provided by the addition of specific ISA or PCI I O cards A wide selection of ISA and PCI cards is available from 3 party sources to provide user flexibility GFK 1543C Chapter 1 Display Station 2020 Features 1 3 1 4 ISA and PCI Card Expansion Display Station 2020 provides two expansion slots The slots available are two ISA and one PCI e One ISA slot e One PCI ISA shared slot not available with IC752WFB2x4 or IC752SPL006 All the expansion slots within the system allow the card to be
45. r Data Bit 7 18 to 25 Ground Display Station 2020 User s Guide July 2000 GFK 1543C Serial Communication Cables 1234 QOO EQ G G Ovo 6789 RS 232C Name PIN Assignment CF DCD Data Carrier Detect 1 BB 2 RX Receive Data BA 3 TX Transmit Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready CA 7 RTS Request to Send CE No RI Ring Indicator To ensure that the installation meets the EMC radiation specification the serial cables must comply with the following requirements The cables must be shielded The D type connector covers must provide EMC shielding e g Metallized plastic or die cast metal covers The cables must be terminated with 360 degree termination of the shield as illustrated below GFK 1543C Chapter 4 Connectors 4 5 Chapter System Operation 5 This chapter provides details of system operation The following topics are covered e System Peripherals e External Keyboard and Mouse e Graphic System e Operator Interfaces e CIMPLICITY Software e Communications GFK 1543C System Peripherals Hard Disk Drive The system provides an internal 3 5 inch bay which is dedicated to the system hard drive The Display Station system has a single internal hard disk drive for the mass storage of data The disk drive is a standard unit with EIDE ATA 2 interface Hard disk bay Floppy Disk Drive
46. re settings The factory default settings are COM Port COM 2 VQ Address 2F8 Hex IRQ 23 These parameters are written into the system registry file by the driver setup utility The driver is installed configured and calibrated at the time of manufacture Touch Screen Calibration Procedure GFK 1543C Due to fluctuations in system requirements and individual touch resistance it may be necessary to calibrate your touch screen after you have licensed your Display Station but before normal use To calibrate your touch screen 1 Ensure that an external keyboard is attached to your system 2 Pressthe Ctrl and Esc keys simultaneously 3 Press the up arrow key until Programs is highlighted 4 Press the right arrow key once and then the down arrow key until the touch option is highlighted 5 Press the right arrow key once and the down arrow key until Touchscreen is highlighted and press the Enter key This opens the Touch Screen Control Program window 6 Press the Alt and C key simultaneously to activate the calibration program 7 Follow the instructions on the screen to calibrate your touch screen 8 Exitthe program after successful calibration of the touch screen Chapter 5 System Operation 5 9 Setting the Backlight Dimming Control 5 10 Display Stations incorporate a backlight dimming control to extend the life of the backlight tubes The dimming control is operated by using the backlight control button located on t
47. reen needs calibration Refer to Touch Screen correspond exactly to touch Calibration Procedure in Chapter 5 Memory Symptom Possible Causes Solution Memory count during powerup Optional SIMM is installed Make sure that the appropriate self test is incorrect incorrectly or is incompatible with memory is installed correctly the Display Station CPU Out of Memory message is System ran out of memory for the Check the memory requirements displayed or insufficient memory application for the application Refer to the error occurs during operation application documentation Install additional memory Too many terminate and stay Modify the startup folder to use resident TSR programs running only those TSR applications that are really needed GFK 1543C Chapter 7 Diagnostics and Troubleshooting 7 3 7 4 External PS2 Mouse Symptom Possible Causes Solution Cursor does not respond to mouse Mouse not plugged in Power down Display Station Plug movement mouse into mouse port on Display Station and reboot The type of mouse is not Use a PS2 mouse supported System is busy Press CTRL ALT DELETE to view task list Mouse not detected Restart Display Station product with external mouse connected Keyboard External keyboard locks up The type of keyboard is not Use a Key Tronic keyboard Most supported keyboards will work However we recommend a keyboard manufactured by Key Tronic K
48. rietary cards fitted in the Display Station 2020 The documentation of the original manufacturers of these cards is supplied with the Display Station Keyboard CPU card PS2 Mouse Port CPU card Serial Ports COM 1 CPU card Parallel Port 25 pin CPU card Network PCI expansion card For details about connectors on proprietary cards you have installed in the Display Station refer to the manufacturer s documentation provided with your card 4 1 4 2 Power Input Series 2020 Display Stations are powered by an internal autoranging AC power supply unit that accepts 85 to 135 and 180 to 250 VAC input ranges The power supply unit also provides a standard IEC outlet socket The power supply input to the Display Station uses a standard IEC cable which is provided with the unit A rocker switch is provided to allow the system to be isolated from the input The power supply unit and the power switch are recessed within the enclosure to ensure that they do not interfere with the mounting of the Display Station into the panel aperture The power supply unit houses an integral ventilation fan that provides cooling for the power supply For power supply details refer to specifications in Appendix A There are no user serviceable fuses in these Display Station units For all equipment that is connected to a power outlet the socket outlet shall be installed near the equipment and shall be easily accessible Display Station 2
49. s powered Failure to observe this precaution could result in damage to the equipment The power switch is located on the side of the Display Station unit next to the input power connector To power up the unit set the rocker switch to the on position During power up the processor will run its normal diagnostic checks and indicate the presence of any errors either with a screen prompt or with warning beeps GFK 1543B 2 1 Setting Up Windows 95 Systems WFB 203 WFB253 Models 2 2 Before you get started you need a PS2 keyboard A PS2 mouse is also recommended to help navigate through the setup screens 1 RS QUO fuel ugue ON E AS 11 12 13 14 Plug in the keyboard PS2 mouse if available and power cord Power on the unit The Windows 95 Setup screen will appear Type your name Press the TAB key and type your company name Press ENTER Read the license agreement Click your choice Click Next Enter the Windows 95 Certificate of Authenticity number found on the front of your Windows 95 manual Press ENTER The network card used in these systems supports Plug amp Play installation Windows 95 will go through setup When prompted for Date Time Properties use your left and right arrow keys to set the time zone to your time zone Press ENTER If you have a printer connected click Next and select your printer model type If not click the Cancel button The Welcome to Windows 95 window will appear
50. ter 5 System Operation 5 5 5 6 Table 5 1 Membrane Keypad Scan Codes Without FN Key With FN Key Display AT Make Scan AT Command Make Scan Code Station Key Command Code Hex with FN Key Held with FN Held 0837 2B5C 0938 352F 0A39 273A 0534 342bE 0635 3320 0736 E 2822 0231 0625 7 8 9 4 5 6 1 2 3 0 SOJIN ajua BR ojo 0332 1A5B 0433 1B5D 0B30 OC5F 0C2D 0D2B FN None Note 1 None None None ENTER Enter 1C0D None None DELETE Delete 53E0 None None PRINT Ctrl P 1910 None None HOME Home 47E0 None None SPACE Space 3920 None None BACKSPACE Backspace OE08 None None ESCAPE Escape 011B None None INSERT Insert 52E0 092A PAGE Pageup 49E0 None None Pagedown 51E0 None None Alt Alt None None Shift Tab None E Left arrow 4BE0 None None gt Right arrow 4DEO None None T Up arrow 48E0 None None Down arrow Fl Fl 3B00 A 1E41 F2 F2 3C00 B 3042 F3 F3 3D00 C 2E43 F4 F4 3E00 D 2044 F5 F5 3F00 E 1245 F6 F6 4000 F 2146 F7 F7 4100 G 2247 F8 F8 4200 H 2348 F9 F9 4300 I 1749 F10 F10 4400 J 244A F11 F11 8500 K 254B F12 F12 8600 L 264C Display Station 2020 User s Guide July 2000 GFK 1543C Table 5 1 Membrane Keypad Scan Codes Continued Without FN Key With FN Key Display AT Make Scan AT Command Make Scan Code Station Key Command Code Hex
51. the software The following sections give tips for customizing the software for the Display Station platform Directory Structure The contents of the Display Station hard drive as shipped from GE Fanuc are listed below Windows NT Systems C CIMCD i386 CIMPLICITY CD C i386 Windows NT CD C TBASE Touch screen drivers C i386 DRVLIB NIC Intel 55 Network drivers C SP4 i386 Service pack 4 drivers C LS120 Imation Superdisk Floppy Backpack drivers Note If you reload any Windows NT component requiring files such as network driver you must reload service pack 4 To do this type C SP4 UPDATE Windows 95 Systems C CIMCD i386 CIM CD C Windows Options CABS Windows 95 CD 2 6 Display Station 2020 User s Guide July 2000 GFK 1543C Reloading Windows NT on the Hard Disk From CD To reload Windows NT you should follow the instructions in the Windows NT manual from Microsoft Corporation After completing the installation the BOOT INI file must be modified to ensure that the touch screen works correctly Edit the BOOT INI file and add the noserialmice com2 option to the end of each entry in the operating systems section of BOOT INI If you have concerns about performing this step call the CIMPLICITY Hotline for assistance Note You must use version TNdriver 1 26 or higher of the touch screen driver to avoid a system crash during boot up You may need to set up the display driver in the event of a reload Go to Control Panel
52. y Tighten each of the clips in turn a little at a time 4 When the springs are fully compressed no further tightening of the clips is necessary The Display Station is locked into place Installing Expansion Cards Display Station 2020 provides three expansion slots e One ISA slot e One PCI ISA shared slot not available on IC752WFB2x4 and IC752SPL006 Models If your card is a Legacy ISA type follow the instructions on page 3 6 then proceed with installation All the expansion slots within the system allow the card to be clamped into place using a clamping bracket with screws adjustable to the height of the card The rear cover of the Display Station must be removed in order to access the ISA and PCI bus cards Ten screws are used to secure the rear panel to the Display unit When these screws are removed the backplate will slide upwards and can then be lifted clear of the main unit GFK 1543C Chapter 3 Hardware Installation 3 3 To avoid a risk of electric shock turn off power to the Display Station and disconnect the power supply before removing the rear cover from the unit To disconnect the unit from the main power remove the power cord To avoid damage from electrostatic discharge adhere to the following precautions when installing ISA and PCI cards e The card is packaged in a static safe bag which protects the product during shipping Before removing the card from this bag be prepared to handle it in a static s