1. LED 7875 User Guide Please read the instruction carefully before use Contents A CY URIS UMC Ol ares A ake tem O PO 2 ME ealalle bo oleji 0 10 1 O O a 3 Technical SIS CTI AL ONS PKP SE ASPA PSV OAO PR O OP os 4 ZE OMRON aD Cl sesrccin tea cicay se ttasaaa sutaiett skoda casa Acad udat dale n ston el 0 n n 0 asd 4 6 4 222 Ma FUNCTION dato 5 SHOW TO Control The FIXtU G dac team a E Ratetaeetietente 8 4 1 Master Slave Built In Preprogrammed Function oocccccnnnncnnnnnononcnnnioccnnnanaconnnos 8 4 2 EASY CONTroller DY CA8 aran 9 AS DINIX CONT do li 9 DMIXSLZ Contursi ala 10 DIVA SEZ CONMNECUON Serratos ee i E aces 11 IFOUDIESAOOUN Pais 12 Cleaning ANG Maintenance noria aia lasl 13 1B 1 Safety Instructions AN Please read the instructions carefully which includes important WARNING information about the installation operation and maintenance Please keep this User Manual for future consultation If you sell the fixture to another user be sure that they also receive this instruction booklet Unpack and check carefully there is no transportation damage before using the fixture It s important to ground the yellow green conductor to earth in order to avoid electric shock Disconnect main power before servicing and maintenance Maximum ambient temperature is Ta 40 C Don t operate it where the temperature is higher than this In the event of serious operating problem stop using the fixture i
2. EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements Innovation Quality Performance
3. display for easy navigation e Ideal for discos pubs parties clubs Mobile DJs etc e Voltage AC 100V 240V 50 60Hz e Power consumption 40W e LED Total 320pcs Red 80pcs Green 80pcs Blue 80pcs White 80pcs e Dimension 457 X 433 X 286mm e Weight 7 0kgs N JB 3 Technical Specifications 3 1 Control Panel 1 Display To show the various menus and the selected functions LED PPM fon omxinput present GMASTER on Master Mode PANE fon Stave Mode Button 6 MENU To select the programming functions 7 DOWN To go backward in the selected functions To go forward in the selected functions 9 ENTER To confirm the selected functions 10 Only for remote control By connect to the 1 4 microphone jack to control the unit for Stand by Function and Mode function 11 DMX output For DMX512 link use 3 pin XLR plug cable to link the next unit 12 DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal 13 Mains output Connect to supply mains power for the next unit 14 Mains input Connect to supply mains power 4B To select any functions press MENU button until the required one is shown on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will automatically return to the main functions without any change after idling 10 seconds
4. Back to the functions without any change press MENU button The main functions are shown below ddr T DMX512 Address Setting Ji GE Slave Mode Normal SL id ll Slave mode 2 Light Show in Random Show Shi m Gh ie Show mode 0 12 LOL Color 1 15 MENU an Sound Mode on Phim j uu Pi SP Sound Mode off En Sound Sensitive 4YPS Blackout Mode Yes Blackout no Blackout Mode No Blackout 1 an LED on aFF LED off Normal argpH ELSE da Pl Inversion Leste Self Test rhe S Fixture Hours uc Software Version 5B DMX 512 Address Setting Press the MENU button up to when the ddr is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX 512 address Once the address has been selected press ENTER button to setup or automatically exit menu mode without any change after 10 seconds Back to the previous functions without any change press MENU button Ol slave Mode Press the MENU button up to when the Sid is shown on the display Pressing ENTER button Use DOWN and UP button to select the St slave 1 or BL d Slave 2 mode Once select press the ENTER button to setup or automatically exit menu mode without any change after 10 seconds To go back to the functions without any change press the MENU button 5 mii Show Mode Press the MENU button up to when the Shiicd is shown on the display Pressi
5. mmediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not connect the device to any dimmer pack Do not touch any wire during operation and there might be a hazard of electric shock To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture The housing must be replaced if they are visibly damaged Do not look directly at the LED light beam while the fixture is on There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs by yourself In the unlikely event your fixture may require service please contact your nearest dealer Due to the magnifying type lens please keep the lens out of contact with direct sunlight Direct sunlight can cause heat to build up inside of the unit which will seriously damage unit For power supply do not connect in series much more than 20 units use another mains supply for next 20 units 2B 2 Technical Specifications e 5 LED clusters each equips with 64 high power LEDs e DMX 512 control 4 channels Function Chase Speed and Strobe e Three operation modes DMX Master Slave mode Sound Active e Great built in programs under Master Slave triggered by music e Optional easy controller CA 8 for instant lighting shows e LED
6. ng ENTER button Use DOWN and UP button to select the bh 0l Random show or show 1 or Sh d Show 2 or or Sh 1d show 12 Once select press ENTER button to setup or automatically exit menu mode without any change after 10 seconds To go back to the functions without any change press the MENU button Color mode Press the MENU button up to when the Sta is shown on the display Pressing ENTER button Use DOWN and UP button to select the Lot color 1 or color 15 Once select press ENTER button to setup or automatically exit menu mode without any change after 10 seconds To go back to the functions without any change press the MENU button Sound mode Press the MENU button up to when the satinl is shown on the display Pressing ENTER button 6B Use DOWN and UP button to select the sound on or sound off Pressing ENTER or BP el or BP 3 mode Once select press ENTER button to setup or automatically exit menu mode without any change after 10 button Use DOWN and UP button to select the seconds To go back to the functions without any change press the MENU button Sens Sound sensitive Press the MENU button up to when the 5 n5 is shown on the display Pressing ENTER button Use DOWN and UP button to change the number 1 or L00 once select press ENTER button to setup or automatically exit menu mode without any change after 10 seconds To go back to the functions withou
7. nit works as the master unit and means 2 light show In order to create a great light show you can set on the second unit to get contrast movement to each other even if you have two units only 4 2 Easy Controller by CA 8 The easy remote control is used only in master slave mode There is a terminator for connect the easy controller inside the fixture By connecting the cable into DMX IN waterproof cable entry gland to the CA 8 terminator of the first fixture you will find that the remote control on the first fixture will control all the other fixtures for Stand by Function and Mode functions Blackout Blackout the unit 1 White Strobe Select Speed 2 Color Strobe Select Show Select Color 1 Fast Function 3 Sound White Strobe Show 1 12 Color 1 15 2 Middle 4 Sound Color Strobe 3 Slow Sound Strobe Show Mode LED slow blinking LED fast blinking LED OFF LED ON 4 3 DMX Controller Using universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the naar is showing on the display Pressing ENTER button 9B and the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds later To go back to the functions
8. ns press the MENU button Software version Press the MENU button up to when the ber is blinking on the display Pressing ENTER button and the display will show the version of software of the unit To go back to the functions press the MENU button again 4 How To Control The Fixture You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By DMX controller No need to turn the unit off when you change the DMX address as new DMX address setting will be effected at once Every time you turn the unit on it will show 7875 on the display After that the unit will be ready to receive DMX signal or run the built in programs 4 1 Master Slave Built In Preprogrammed Function By linking the units in master slave connection the first unit will control the other units to give an automatic sound activated synchronized light show This function is good when you want an instant show You have to set the first unit in master mode and select 6h_b random show 25 show 1 or or show 12 and speed Its DMX input jack will have nothing 8B plugged into it and its master LED will be constantly on and sound LED will flash to the music The other units will have to select normal or 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain and the slave LED lights will be constantly on 2 light show In slave mode means the u
9. r 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 12B 8 Cleaning And Maintenance The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics e Clean with soft cloth using normal glass cleaning fluid e Always dry the parts carefully e Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 13B Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 amp Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991
10. rminator to reduce signal errors Solder a 120 ohm 14W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually O amp 1 are equal to 1 5 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 5 not used 11B 7 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The fixture does not work no light 1 Check the connection of power and main fuse Measure the mains voltage on the main connector U Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy controlle
11. t any change press the MENU button iris Blackout mode Press the MENU button up to when the bi idl is shown on the display Pressing ENTER button Use DOWN and UP button to select the blackout or ho normal Once select press ENTER button to setup or automatically exit menu mode without any change after 10 seconds To go back to the functions without any change press the MENU button 3 O LED display Press the MENU button up to when the Led is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select display on or oF Fiidisplay off mode Once select press ENTER button to setup or exit menu mode without any change after 10 seconds Back to the functions without any change press MENU button again _ II Display Inverse Press MENU button until is blinking on the display Use DOWN and UP button to select ci SP normal or inverse press ENTER button to setup Back to the functions without any change press MENU button 7B E El Self Test Press the MENU button up to when the E 5E is blinking on the display Pressing ENTER button and the unit will run the built in programmer for self test To go back to the functions press the MENU button LE r mu 5 Fixture Hours Press the MENU button up to when the Fhr is blinking on the display Pressing ENTER button and the display will show the number of working hours of the unit To go back to the functio
12. without any change press the MENU button again If you use please refer to the following diagram to address your DMX512 channel for the first 4 2 units DMX512 Configuration Chi Ch2 Ch3 Ch4 250 255 SoundActive 235 255 Chase 12 255 Fast 214 234 Chase 11 130 249 Asynchronous n Show 171 191 Chase 9 150 170 Chase 8 128 149 Chase 7 010 129 ynctirongue 107 127 Chase 6 ow 086 106 Chase 5 064 085 Chase 4 043 063 Chase 3 dd E 022 042 Chase 2 ol Slow 000 021 Chase 1 4 channels as a group please refer to the DMX configuration of 4 channels to control the other channels 10B 6 DMX512 Connections The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels Termination reduces signal errors and to avoid signal transmission problems and interference lt is always advisable to connect a DMA terminal Resistance 120 ohm 1 4W between pin2 DMX and pin3 DMX of the last fixture 1 Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y cable Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 2 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a te