Home
LifeChoice User Manual
Contents
1. i COG Presented With Compliments From www DirectHomeMedical com Ss ss ee T Fo i a LifeChoice he On the go with O e J Inova Labs Inc 3500 Comsouth Drive Suite 100 Austin TX 78744 USA www LifeChoiceOxygen com Phone 1 800 220 0977 CE 0459 Represented in Europe by QNET BV Hommerterweg 286 1 6436 AM Amstenrade The Netherlands XYC276 REV F Nov 2011 i Introduction 2 Application 2 Warnings 3 User Controls 4 LifeChoice Mobility Package 5 LifeChoice Part Names 5 Operating Instructions 6 Powering the LifeChoice 7 Resetting the External Battery 9 Battery Charging 9 Operating Procedure 10 Alarms Light Indicators 13 Routine Maintenance 16 Specifications 17 Warranty 21 Accessories x Disposal 25 This patient manual will familiarize you with the LifeChoice Portable Oxygen Concentrator E POC and its accessories Be sure to thoroughly read all of the information in this manual in its entirety before using the LifeChoice POC The LifeChoice POC is an internally powered type BF device when powered by the internal battery and a Class II Type BF device when connected to the external AC power supply DC power supply or rechargeable battery The essential performance of the LifeChoice POC is to provide oxygen at a volume that remains within tolerance the tolerance was defined based on technical judgement from within the manufacturer s expertise in this specific medical application
2. Guidance Portable and Mobile RF communications equipment should be used no closer to any part of the Model XYC100 including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended Separation Distance d 1 17 x sqrt P d 1 20 x sqrt P d 1 17 x sqrt P 80MHz to 800MHz d 2 33 x sqrt P 800MHz to 2 5GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol Co NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a The ISM industrial scientific and medical bands between 150 kHz and 80 MHz are 6 765 MHz to 6 795 MHz 13 553 MHz to 13 567 MHz 26 957 MHz to 27 283 MHz and 40 66 MHz to 40 70 MHz b The compliance levels in the ISM frequency bands between 150 kHz and 80 MHz and in the frequency range 80 MHz to 2 5 GHz are intended to decrease the likelihood that mobile portable communications
3. In addition the device s ability to detect certain error conditions such as low concentration or no breath and create an alarm is also considered a part of essential performance This manual applies to the LifeChoice POC XYC100 INDICATIONS FOR USE The LifeChoice Oxygen Concentrator is used on a prescriptive basis by patients who are diagnosed as requiring supplemental oxygen This oxygen concentrator will provide supplemental high concentration oxygen to these patients It is not life supporting nor life sustaining It may be used continuously in a home institution or travel environment The LifeChoice is also portable The LifeChoice POC is FAA approved for air travel The required FAA sticker is located on the bottom of the LifeChoice POC FAA approval is listed as Inova Labs LifeChoice Every airline has specific information required for traveling with oxygen Before traveling review your airline s specific requirements Authorized by US FAA for use onboard aircraft 14CFR Part 121 Docket No FAA 2004 185963 SFAR 106 Rin 2120 A181 Symbol Description Symbol Description Symbol Description E TTN ES Temperature Radio Limitation A Frequency Huinidity tye Device that has conductive contact General Warning REF Catalogue Number Caution CE Marking Ss B Risk of Danger ga Danger No Smoking gt EU Authorized T Keep D uthorize PC 10 11 12 LS 14 15 16 This device is NOT INTE
4. It takes a minimum of 4 hours for a discharged internal battery to fully charge It is recommended to recharge the battery even if only partially depleted as often as possible To check the battery charge level disconnect the LifeChoice POC from all external power sources and power the LifeChoice POC on Once fully powered on press the Battery Check to verify internal battery charge level If not charged for the correct amount of time a 100 battery charge indicator green LED light may be illuminated but the actual charge could be between 85 100 The internal battery cannot be overcharged and it is recommended to leave the LifeChoice POC plugged in via the AC or DC adapter as often as possible When charging the LifeChoice POC from the supplied AC or DC adapter confirm that the green LED light above the Battery Check is solid green fora lit red LED light If lit press and hold the pink button until the red LED light turns off to reset Put the battery back in the case This indicates the LifeChoice has recognized an external power charging oan source The green LED light will be solid green if the system is on or off 2 If charging the internal and external battery at the same time powered on or off first connect the external battery to the LifeChoice POC and verify that the green LED light above the Battery Check illuminates solid green If the green LED light is not solid green follow
5. 2 or 3 illuminates and will flash each time inhalation is detected indicating that a pulse of oxygen has been delivered Check to make sure your unit s battery is fully charged minimum of 4 bours charge time for fully depleted battery before venturing out with LifeChoice POC for the first time or upon subsequent use To accurately measure the internal battery charge the unit must be powered on and disconnected from the AC DC power supply or external battery The battery gauge indicator LED lights next to the Battery Check will illuminate to indicate the level of battery charge 25 to 100 The battery charge indicator LED lights are a reference only If a fully depleted internal battery is not charged for a minimum of 4 hours it will not supply 2 hours of use If not charged for the correct amount of time a 100 battery charge indicator LED light may be illuminated but the actual charge could be less than 100 To turn the LifeChoice POC off press Power and hold for 2 seconds until the green LED light above Power goes out and the unit shuts off When the LifeChoice POC is powered off the internal fans will continue to operate for approximately 30 45 seconds for additional cooling Start Up A brief audible beep sounds at start up when Power is pushed Release Power as soon as the tone sounds Pressing Power for extended time after the audible beep will cause the system to cycle back to the off position The LifeCh
6. 3500 Comsouth Drive Suite 100 Austin Texas 78744 Corporate Office 512 617 1700 XYC276 REV F Nov 2011
7. Oxygen Concentration Sensor Alarm 85 or Less Flow Control Pulse Settings 1 2 amp 3 LPM Equivalent to Continuous Flow 20 Mode of Operation Continuous equipment and mobility portable Weight 4 9 Pounds 2 2kg Dimensions Height 9 5 24cm Width 7 5 19cm at widest point Depth 3 125 7 9cm Power Supply AC 100 to 240 VAC 50 to 60 Hz cycles DC 12 to 19 VDC LifeChoice Oxygen Concentrator XYC100 Input 19Vdc 6A External AC Power Adapter XYC103AC Input 100 240V 2 5A Output 19V 6 3A External DC Power Adapter XYC104DC Input 11 5 16VDC 5 6A Output 19V 6 3A External Rechargeable Battery XYC102 Input 14 2 23 7V Output 14 2 23 7V Approximate Internal Battery Duration 2 Hours Minimum Internal Battery Recharge Time 4 Hours Approximate External Battery Duration 3 Hours Minimum External Battery Recharge Time 6 Hours Warm up Time 2 Minutes with an LED Signal Sound Less than 50 Decibels at 10 ft 3 05m 54 4 Decibals at 3 3ft 1m Operational Humidity Range 20 to 95 Non condensing Operational Altitude Max 10 000 Feet 3km Environmental Conditions for Use Storage and Transport 104 F 95 140 F Xt 40 C Xt 60 C 41 F 20 gt ASF A Ce Operational 20 C Storage 1 When powered by the external AC adapter external DC adapter or external or internal battery Oxygen Concentration as Altitude Increases 100 Medical electrical equipment 9 needs special precautions regardin
8. POC plugged into or powered by external source AC DC or external battery Green LED light above Battery Check is solid green Action You may begin to use your LifeChoice POC unit LifeChoice POC is functioning normally LifeChoice POC is functioning normally LifeChoice POC is functioning normally LifeChoice Portable Oxygen Concentrator 15 ALARM TABLE Audible Problem yas LED Light Alarm Action Check the cannula connection Ensure No breath that you are breathing detected by ene TT through your nose the unit for p Once the system approximately lt P detects a breath the 75 seconds alarm will shut off Red LED light next wA aem ae If the alarm persists contact your equipment provider Connect the Low Battery a LifeChoice POC Alarm i A unit to a DC adapter Approximately a an AC adapter every 65 or change to another source of oxygen e a cons Red LED light above Battery Check slowly flashes Connect the Critical Low z LifeChoice POC Battery Alarm Fast audible Y F unit to a DC adapter Approximately beep Unit _ i an AC adapter or change to another source of oxygen 10 seconds of shuts down battery power Red LED light above Battery Check begins flashing quickly Turn off the unit Change to another General malfunction Continuou
9. equipment could cause interference if it is inadvertently brought into patient areas For this reason an additional factor of 10 3 has been incorporated into the formula used in calculating the recommended separation distance for transmitters in these frequency c Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the Model X YC100 is to used exceeds the applicable RF compliance level above the Model XYC100 should be observed to verify normal operation If the abnormal performance is observed additional measures may be necessary such as re orienting or relocating the Model XYC100 d Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3V m Separation Distance Portable amp Mobile RF Communications Equipment Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the MODEL XYC100 The Model XYC100 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Model XYC100 can help prevent electromagnetic interference by maintaining a minimum
10. equivalent to new or re conditioned As far as national laws permit the warranty coverage will not be extended or renewed or otherwise affected due to Inova Labs authorized repair or replacement However part s repaired or replacement product will be warranted for the unexpired portion of the original Limited Warranty or for sixty 60 days from the date of repair or replacement whichever is longer NO REPRESENTATIVE OF INOVA LABS HAS AUTHORITY TO MAKE ANY REPRESENTATIONS OR PROMISES EXCEPT AS STATED HEREIN THIS LIMITED WARRANTY IS EXCLUSIVE AND GIVEN AND ACCEPTED IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT INOVA LABS SHALL HAVE NO FURTHER LIBALITY FOR ANY DAMAGE LOSS COST OR FEE OF WHATEVER KIND OR NATURE WHETHER FORSEEABLE OR NOT INCLUDING BUT NOT LIMITED TO ATTORNEYS FEES CONSEQUENTIAL GENERAL SPECIAL INCIDENTAL INDIRECT EXEMPLARY OR PUNITIVE DAMAGES REGARDLESS OF THE FORM OF THE CLAIM WHETHER IN CONTRACT TORT OR OTHERWISE ARISING OUT OF OR RELATING TO INOVA LABS PRODUCTS AND EVEN IF INOVA LABS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES LOSSES COSTS OR FEES TO THE EXTENT PERMITTED BY APPLICABLE LAW INOVA LABS LIABILITY HEREUNDER OR RELATING HERETO SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT REGARDLESS OF THE FORUM AND REGARDLESS OF WHETHER ANY ACTION OR
11. light above the Battery Check does not turn solid the source is not recognized If charging the unit through the external battery when this occurs the charge will not reach the internal battery This may be an indication the external battery needs to be reset Instructions for resetting the battery are provided in the Powering the LifeChoice POC section When more than two hours battery operation is needed the LifeChoice POC should be powered using the external battery first and then the internal battery The LifeChoice POC will automatically switch to the internal battery once the external battery has been depleted Carry Case The LifeChoice POC is recommended and designed to be operated and stored in its carry case at all times Verify that the intake vents are clean and free from obstruction Connect the nasal cannula securely to the LifeChoice POC cannula nozzle fitting The LifeChoice POC can be powered in four different ways the internal battery an AC power supply DC power supply or the external battery The rechargeable batteries are maintenance free and can only be exchanged at the factory 1 Internal Battery A rechargeable internal battery is located within each LifeChoice POC unit When it is fully charged it supplies power to the Life Choice POC for up to 2 hours When using internal battery power the green LED light above the Battery Check will illuminate and flash slowly When the AC
12. CLAIM IS BASED ON CONTRACT TORT OR OTHERWISE PURCHASER AGREES AND ACKNOWLEDGES THAT THE PRODUCT IS OF A SIZE DESIGN AND CAPACITY SELECTED BY ITS MEDICAL PROVIDER NO AGREEMENT VARYING OR EXTENDING THIS LIMITED WARRANTY SHALL BE BINDING UPON INOVA LABS UNLESS IN WRITING SIGNED BY A DULY AUTHORIZED REPRESENTATIVE OF INOVA LABS Governing Law and Jurisdiction The rights and obligations of the parties pursuant to this Limited Warranty and any dispute arising hereunder shall be governed by and interpreted in accordance with the internal but not the conflicts laws of the State of Texas USA The 1980 U N Convention on Contracts for the International Sale of Goods shall not apply If any provision of this Limited Warranty is inconsistent with applicable laws relating to Purchaser Purchaser agrees to waive any and all rights and remedies it may have under such laws to the extent it may waive such rights and remedies This Limited Warranty is offered as an additional benefit to Purchaser s statutory rights and it does not affect such statutory rights in any way The parties agree and consent that the state or federal courts in Texas shall have exclusive jurisdiction with respect to any dispute arising out of or relating to this Limited Warranty EACH PARTY EXPRESSLY WAIVES ALL RIGHTS TO A TRIAL BY JURY Technical Support Please contact the local medical equipment company that provided or sold the LifeChoice POC to you for any technical or emergency s
13. DC or external battery is plugged into the LifeChoice POC whether powered on or off the green LED light above the Battery Check will illuminate solid green This is verification that the external source has been recognized When using an external source to power the LifeChoice POC verify that the green LED light above the Battery Check is solid green indicating the system is being powered by the external source If not connected to an AC or DC adapter the internal battery will slowly discharge over time even when not in use Always check the battery level prior to use to ensure adequate charge level AC Power Supply An AC power supply allows the LifeChoice POC to be connected to a 100 240 volt 50 60 Hz outlet The power supply converts 100 240 volt AC to a DC voltage for the LifeChoice POC unit When the unit is operated with the AC power supply power from the AC outlet powers the unit and recharges the internal and or the external battery simultaneously When using an external source to power the LifeChoice POC verify that the green LED light above the Battery Check is solid green indicating the system is being powered by the external source DC Power Supply A DC power supply can be connected from the LifeChoice POC unit to an automobile s boat motor home etc 12 volt DC outlet When the system is connected to the automobile s vehicle s DC outlet power from the automobile vehicle battery powers the LifeChoice POC unit an
14. NDED to be life sustaining or life supporting This device should be used only when prescribed by a physician In certain circumstances oxygen therapy can be hazardous Please seek medical advice before using the LifeChoice POC U S Federal law restricts this device to sale by or on the order of a physician The LifeChoice POC is designed to provide a flow of high purity oxygen Patients with a fast breathing rate or requiring high oxygen flow may require more oxygen than the LifeChoice POC can produce and therefore may not be a suitable candidate This device is not suitable for patients who are unable to hear or see alarms or communicate discomfort If the patient shows any signs of discomfort a physician should be consulted immediately It is the responsibility of the patient and or provider to make back up arrangements for an alternative oxygen supply when traveling Inova Labs Inc assumes no liability for persons choosing not to adhere to manufacturer recommendations Availability of an alternate source of oxygen is required in case of power outage or mechanical failure Consult your physician or medical equipment supplier for the type of back up system required The LifeChoice POC is designed to be used in the provided approved carry case The LifeChoice should be located so as to avoid pollutants or fumes Do not use oil grease or petroleum based products on or near the LifeChoice POC Do not use power supplies adapters car
15. d recharges the internal and or external battery simultaneously When using an external source to power the LifeChoice POC verify that the green LED light above the Battery Check is solid green indicating the system is being powered by the external source The AC DC and external battery are each connected to the receptacle on the top of the LifeChoice POC External battery shown as example If the external battery is connected to the LifeChoice POC the AC or DC adapter can be connected to the external battery and will charge both batteries and operate the LiteChoice POC simultaneously 4 External Battery A rechargeable external battery is included with every LifeChoice POC XYC100 unit When fully charged it supplies power to the Life Choice POC for up to 3 hours When using external battery power the green LED light above the Battery Check will illuminate solid green When using the external battery to power the LifeChoice POC the system will automatically switch to internal battery power when the external battery has been depleted approximately 3 hours When this occurs the green LED light above the Battery Check will turn from solid green to flashing green When the external battery is required for extended time away from an AC or DC power source it is recommended to power the LifeChoice POC with the external battery first and then the internal battery for maximum combined battery time Charge time for a de
16. distance between portable and mobile RF communications equipment transmitters and the Model XYC100 as recommended below according to the maximum output power of the communications equipment Rated Maximum Separation distance according to the frequency of transmitter m output power of 150kHz to 80MHz 150kHz to 80MHz S0MHz to 800Mhz 800Mbz to 2 5GHz transmitter W outside ISM bands in ISM bands 2 z d 1 17 x sqrt P d 1 20 x sqrt P d 1 17 x sqrt P d 2 33 x sqrt P For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80MHz and 800MHZz the separation distance for the higher frequency range applies NOTE 2 The ISM industrial scientific and medical bands between 150 kHz and 80 MHz are 6 765 MHz to 6 795 MHz 13 553 MHz to 13 567 MHz 26 957 MHz to 27 283 MHz and 40 66 MHz to 40 70 MHz NOTE 3 An additional factor of 10 3 has been incorporated into the formulae used in calculating the recommended separation distance for transmitters in the ISM frequency bands between 150 kHz and 80 MHz and in the frequency range 80 MHz to 2 5 GHz to decrease the likelihood that mobile portable communications equipment could cause interference if it is inadvertently b
17. e The LifeChoice POC can be operated using AC power DC power or battery power during transport while inside the approved carry case 4 Way Carry Case Use as a convertible backpack over the shoulder strap briefcase or waist pack LifeChoice 4 Accessory Bag LifeChoice Portable Oxygen Concentrator with 2 hour internal battery 1 Three hour external battery with carry case AC power adapter universal 100v 2400 50bz 60bz 1 Standard single lumen 7 foot 2 meter long nasal cannula DC power adapter 12v with standard car adapter plug Cannula Nozzle Fitting Battery Charge Level Gauge Power 8 Battery Check Alarm Indicator Light 9 Pulse Settings 1 2 3 Breath Auto Mode Active High Intake Vents LO Vents located on front and back Breath Auto Mode 5 Sleep Low os FAA Approval Sticker Exhaust Fan D oO located on bottom Vents BEFORE USING THE LIFECHOICE POC FOR THE FIRST TIME The LifeChoice POC and external battery should be charged for a minimum of 6 hours before initial use Connect the external battery to the LifeChoice POC connect the AC adapter to the external battery and plug the AC adapter into an electrical outlet Make sure to verify the green LED light above the Battery Check is solid green This indicates the system recognizes the external power source If the external battery is plugged into the Life Choice POC and the green LED
18. e table below for detailed coverage under this Limited Warranty The Limited Warranty extends only to the first Purchaser it is not transferable and begins on the date of purchase as evidenced by the sales receipt directly from Inova Labs or through one of its authorized distributors This Limited Warranty is only offered in connection with sales through Inova Labs authorized distribution channels ITEM LENGTH OF COVERAGE ITEM LENGTH OF COVERAGE Oute STE UI stn caer steep ce res caesar at neten en ea ean 3 years ka onal a a Mere UM ERR hare mm ene Cea 1 year COMPE SSON mirai fan te an tere eee tee 3 years Battery liibennel eaten areecet semen teeta 1 year Computer Controller Battery External e BO W101 0 10 0 ce arn tae nema OEE ge rr va MINE ean 3 years Supplemental sauces becr ee eter cee owes eee 1 year PSA Luns Assemb e pe ee ee ee 3 years PAGGCSSOME GE eee er ee ee rere eee 1 year The Limited Warranty Excludes From Coverage 1 Defects caused by or related to Abuse misuse negligence or accident Failure to comply with instructions contained in the Operating Manual Alteration or modification by Purchaser Unauthorized repairs or alterations Environmental conditions including but not limited to water chemicals fumes in the atmosphere extreme heat spillage of food or liquid sand dirt or the like f Lack of regular preventive maintenance and cleaning g Damage in shipment h Other acts beyond the reasonable con
19. g EMC and needs to 90 be installed and put into amp service according tothe EMC amp 8 information provided in the go accompanying documents 75 2000 610 4000 1219 8000 2438 12000 3657 Altitude feet meters Immunity Requirements Guidance and Manufacturer s Declaration Electromagnetic Immunity The Model XYC100 is intended for use in the electromagnetic environment specified below The customer or the user of the Model X YC100 should assure that it is used in such an environment Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment Guidance Electrostatic Discharge 6 kV contact ESD IEC 61000 4 2 gKV ai 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 2 kV for power Electrical Fast supply lines Transient Burst IEC 61000 4 4 1kV for input output lines 1 kV line to line Surge IEC 61000 4 5 2kV line to earth lt 5 Ur 95 dip in Ur for 0 5 cycle Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 40 Ur 60 dip in Ur for 5 cycles 70 Ur 30 dip in Ur for 25 cycles lt 5 Ur gt 95 dip in U for 5 seconds Power Frequency 50 60Hz Magnetic Field IEC 61000 4 8 2 kV for power supply lines Not applicable for input output lines 1
20. h Alarm When the LifeChoice POC is powered on but does not sense breathing within a predetermined time period approximately 75 seconds an audible alarm beeps and the red LED light next to Alarm flashes If this occurs check the connection from the cannula to the LifeChoice POC make sure that the nasal cannula is positioned properly on your face and ensure that you are breathing through your nose Once the system detects a breath the alarm will automatically turn off If the alarm continues to sound change to an alternate source of oxygen and contact your equipment provider General Malfunction Alarm If the LifeChoice POC has a general malfunction a continuous audible alarm sounds and the red LED light next to Alarm will continuously illuminate When this occurs the concentration of oxygen that LifeChoice POC is supplying is outside of specifications You should change to another source of oxygen and contact your equipment provider 14 NORMAL OPERATION INDICATORS Audible Alarm Normal Operation LED Light Alarm LifeChoice Brief POC Audible turned on Tone Green LED lights of Power Active High Mode and Pulse Setting of 1 are illuminated LifeChoice POC has detected an inhalation breath and is delivering a pulse of oxygen Green LED light of selected pulse setting flashes with each breath LifeChoice POC powered by internal battery Green LED light above Battery Check slowly flashes LifeChoice
21. kV line to line 2kV line to earth lt 5 Ur gt 95 dip in Ur for 0 5 cycle 40 Ur 60 dip in Ur for 5 cycles 70 Ur 30 dip in Ur for 25 cycles lt 5 Ur gt 95 dip in U for 5 seconds Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of the Model XYC100 requires continued operation during power mains interruptions it is recommended that the Model X YC100 be powered from an uninterruptible power supply or a battery Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE Uris the a c mains voltage prior to application of the test level Immunity Requirements Guidance and Manufacturer s Declaration Electromagnetic Immunity The Model XYC100 is intended for use in the electromagnetic environment specified below The customer or the user of the Model XYC100 should assure that it is used in such an environment IEC 60601 Test Level Immunity Test Conducted RF 3 Vrms IEC 61000 4 6 150 kHz 80 MHz outside ISM bands 10 Vrms 150 kHz 80 MHz in ISM bands Radiated RF 3 V m IEC 61000 4 3 80 MHz 2 5 GHz Compliance Level 3 V 10 V 3 V m Electromagnetic Environment
22. l battery AC or DC adapters are connected to the system the internal fans will operate for approximately 4 hours to help keep the internal battery cool during charging 3 Press Power once to turn on An audible beep will occur and the green LED light above the Power Active High Mode and Pulse Setting of 1 will illuminate This indicates that LifeChoice POC is powered on is ready for use and settings may now be changed Pressing Power for extended time after the audible beep will cause the system to cycle back to the off position IN CAUTION Do not place cannula into nasal passages until the LifeChoice POC is fully powered on Breathing through the cannula during start up will prevent the system from powering on 4 There are two inhalation sensitivity modes on the control panel Active High and Sleep Low which automatically adjust based on oxygen requirements No action is required to start this feature Bi ACTI HIGH ODE LEEP SLOW gt Select the flow setting 1 2 or 3 as prescribed by your doctor These settings are equivalent to 1 2 or 3 LPM settings on a continuous flow device Place the nasal cannula in the nasal passages and breathe normally When the LifeChoice POC senses inhalation oxygen is supplied through the cannula The duration of this pulse flow and size of the pulse is dependent upon the pulse flow setting 1 2 or 3 selected The green LED light above the selected number 1
23. oice POC will not power on if the cannula is being moved or inserted in the nasal passages during start up Low Battery Alarm As the internal battery power approaches a low level less than10 minutes of battery power remaining the green LED light next to the Battery Check turns red and flashes slowly There is also an audible long loud beep that will sound once every 65 seconds When this occurs connect the LifeChoice POC to a DC power outlet an AC power outlet a fully charged external battery or change to another source of oxygen immediately When there is approximately 10 seconds of battery power remaining the red LED light above the Battery Check that was slowly flashing will begin flashing quickly and a fast audible beep will sound after which the unit will shut off When this occurs connect the LifeChoice POC to a DC power outlet an AC power outlet a fully charged external battery or change to another source of oxygen immediately When the LifeChoice POC is connected to a DC power outlet or to an AC power outlet the unit operates while recharging the internal battery simultaneously The level of battery charge is indicated by disconnecting the LifeChoice POC from the AC or DC adapters while powered on and pressing Battery Check The battery charge indicator LED lights are for reference only If a fully depleted internal battery is not charged for a minimum of 4 hours it will not supply 2 hours of use No Inhalation No Breat
24. pleted external battery is a minimum of 6 hours with either the AC or DC adapter To check charge level on the external battery disconnect from AC or DC adapters press and hold yellow button on the top of the external battery LED lights will illuminate indicating charge level When the LifeChoice POC is in use and the external battery is plugged into the unit verify that the green LED light above the Battery Check turns solid green If the LED light does not illuminate solid green when the external battery is connected to the LifeChoice POC this indicates that the LifeChoice POC is not being powered by the external battery and the external battery may have tripped due to a power surge To prolong the level of charge when not in use it is highly recommended that the external battery be plugged into itself This is done by inserting the male end of the plug into the female receptacle on the battery pack Reset the external battery as indicated in the following steps LifeChoice Portable Oxygen Concentrator RESETTING THE EXTERNAL BATTERY 1 Unplug the external battery from the charger and the LifeChoice POC 2 Remove the battery from the case 3 Look at the end of the battery with the cable BATTERY CHARGING To charge the internal battery connect LifeChoice POC to either an AC power supply and a 100 240 volt 50 60 Hz AC power outlet or connect it to a DC power outlet in an automobile boat motor bome etc
25. rm Audible Signals An audible signal beep indicates either a change in operating status or a condition that may need response alarm Gross Particle Filter A filter mesh is in place inside the intake vents on the front and back of the concentrator during operation to keep large particles and debris out of the intake air See Section Air Intake Filter Cleaning for cleaning instructions Nasal Cannula A standard single lumen nasal cannula or equivalent must be used with the LifeChoice POC to provide oxygen from the concentrator A standard single lumen type cannula 7 foot 2 meter is recommended for use An Adult Nasal Cannula like 1107 by Ventlab Corporation is supplied with each LifeChoice POC purchase For replacement cannulas please contact your local medical equipment supplier Cannula Nozzle Fitting The nasal cannula connects to the oxygen output nozzle at the top of the LifeChoice POC Do not place cannula into nasal passages until the LifeChoice POC is fully powered on Breathing through the cannula during start up will prevent the system from powering on Breath Auto Mode LED There are two inhalation sensitivity modes on the control panel Active High and Sleep Low which automatically adjust based on oxygen requirements Pulse Setting Controls There are three individual pulse flow controls on the panel 1 2 and 3 which are equivalent to 1 2 or 3 liters per minute settings on a continuous flow devic
26. rought into patient areas NOTE 4 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Emissions Requirements Guidance and Manufacturer s Declaration Electromagnetic Emissions The Model XYC100 is intended for use in the electromagnetic environment specified below The customer or the user of the Model XYC100 should assure that it is used in such an environment RF Emissions CISPR 11 The Model XYC100 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment The Model XYC100 is suitable for use in all establishments including domestic establishments and those directly connected to the public low Voltage Fluctuations Flicker Emissions C j voltage power supply network that supplies buildings IEC 61000 3 3 Dai used for domestic purposes INOVA LABS INC LIMITED WARRANTY AND DISCLAIMER Limited Warranty NOTE This Limited Warranty does not affect Purchaser s statutory rights under applicable national laws Inova Labs Inc Inova Labs warrants that each new LifeChoice Portable Oxygen Concentrator POC shall be free from defects under normal use operation and service for three 3 years Any LifeChoice POC Accessories the Sieve Bed and all Batteries are warranted for one 1 year See th
27. ry bags or accessories other than those which come with the LifeChoice POC The use of non specified accessories may impair equipment performance and will void all warranties The LifeChoice POC produces enriched oxygen gas which accelerates combustion DO NOT ALLOW SMOKING OR OPEN FLAMES within 10 feet 3 meters of this device while in use Cigarette cigar pipe SMOKING while using the LifeChoice POC will VOID all warranties Never operate the LifeChoice POC in the accessory bag Accessory Bag e tm Do not submerge the LifeChoice POC or any of the accessories in liquid Do not expose to water or precipitation Do not operate in rain This could lead to damage Portable and mobile RF communications equipment can effect medical electrical equipment The LifeChoice POC should not be used adjacent to or stacked with other equipment If adjacent or stacked use is necessary the POC should be observed to verify normal operation in the configuration in which it will be used JN DANGER gS W No smoking or open flame The user controls on the LifeChoice POC are specifically designed to be pressed by a finger Never press any of the buttons with a pen screwdriver stylus or any other object Pressing the buttons with any hard sharp and or small object can damage the user controls and void all warranties Indicator Lights Colored lights indicate either a change in operating status or a condition that may need response ala
28. s of the audible LifeChoice alarm POC source of oxygen and contact your Red LED light next to Alarm equipment provider continuously illuminates The LifeChoice bas no end user repairable parts Intake Vent Cleaning One vent located on each side of the LifeChoice POC At least once a week or anytime the gross mesh air filter intakes appear dirty use a cotton swab Q Tip or similar to clean the mesh filter media in the intake vents on the front and back of the unit Follow these steps to properly clean the air intake filter Gently rub the cotton swab along the intake vents front and back of unit to clean and remove any debris from the intake filter mesh Do not poke or gouge the mesh filter just gently rub the cotton swab cleaner along the intake vent areas The LifeChoice POC does not need to be removed from the carry case to clean the air intake filter as described above Nasal Cannula Inspection At least once a week visually inspect the nasal cannula Make sure there are no kinks or obstructions Replace as needed with a standard 7 foot 2 meter single lumen type cannula from your local medical equipment supplier Reserve Oxygen Supply Your equipment provider should provide or suggest an alternative source of supplemental oxygen therapy in case there is a mechanical failure or power outage Maximum outlet pressure 19 psi 134 kPa Device Electrical Classification Class I Oxygen Concentration 90 3
29. steps in battery charging section to determine if the external battery has tripped If the green LED light is solid green connect the AC or DC adapter to the external battery and charge for 6 hours The LifeChoice POC can be used while charging with AC DC power Locate and position the LifeChoice POC so that the intake vents and exhaust fan vents are not obstructed The unit particularly the air intake vents and the exhaust fan vents should be located in a well ventilated space The unit may be powered by the internal battery external battery DC power supply or AC power supply using the DC or AC adapters If you are in an automobile boat motor bome etc connect one end of the DC adapter into the LifeChoice POC power inlet and the other end into the DC outlet or If you are near an AC Connect one end of the outlet connect one end external battery into the of the AC adapter into LifeChoice POC power the LifeChoice POC inlet power inlet and the other end into the AC outlet or Plugging the AC or DC adapter directly into the Lifechoice POC will charge the internal battery and operate the system at the same time The external battery pack can be connected to the LifeChoice POC and the AC or DC adapter can then be plugged into the external battery This configuration will charge the internal and external batteries and operate the system at the same time If the LifeChoice POC is powered off and the externa
30. ters chargers for home and car RV motor boat use etc and nasal cannula Each LifeChoice POC comes with a limited three 3 year warranty Model Number XYC200 Includes unit 7 5 w x 3 125 d x 9 5 b 4 9 pounds 4 way carry case which can be used as a convertible backpack over the shoulder strap briefcase or waist pack 2 hours of battery time and nasal cannula Each LifeChoice POC comes with a limited three 3 year warranty Inova Labs expects end users to dispose of LifeChoice POC in an environmentally friendly X way Electrical and electronic equipment is label with the crossed out wheeled bin symbol indicating that the equipment should be disposed of by the end user separate from other types of waste The LifeChoice POC device contains lithium ion batteries and the end users should contact Inova Labs or their local distributor for disposal collection and recycling options and terms and conditions for their country In 2002 the European Union introduced the Directive on Waste Electrical and Electronic Equipment WEEE The main aim of the Directive is to ensure that WEEE is collected and treated separately WEEE items may contain hazardous substances that should not end up in the human environment and can have adverse effects on it if they do LifeChoice On the go with O www LifeChoiceOxygen com 1 800 220 0977 Manufactured and Distributed by Inova Labs Inc
31. trol of Inova Labs 2 Deterioration due to normal wear and tear 3 Regular maintenance and service items ono oe Warranty Service and Coverage Purchaser s exclusive remedy and Inova Labs sole obligation hereunder shall be limited to repair replacement or refund of the purchase price at Inova Lab s option However this Limited Warranty shall not exclude or limit 1 Purchaser s statutory rights under the applicable national laws or 2 Purchaser s rights against the authorized distributor or vendor All items claimed to be defective within the warranty period shall be properly packaged and shipped on a prepaid basis to Inova Labs USA sales or its authorized distributor at Purchaser s expense A prior obtained Return Authorization Number issued by Inova Labs USA or its authorized distributor must properly identify returned items together with proof of purchase date Items returned without a Return Authorization Number shall be refused and returned to Purchaser at Purchaser s expense Inova Labs shall pay for regular shipment back to Purchaser for repair or replacement of items under this Limited Warranty Purchaser shall notify Inova Labs or its authorized distributor of the alleged defect within a reasonable time of discovery of the issue and in any event no later than prior to the expiry of the Limited Warranty coverage When repairing or replacing the item Inova Labs may use functionally equivalent products or parts that are new
32. upport LifeChoice Portable Oxygen Concentrator 23 ACCESSORIES ADDITIONAL REPLACEMENT SPARE Product Product Number Description Standard carry case for LifeChoice POC comes complete with strap system that allows case to be used as a back XYC055 pack shoulder strap waist strap or carried as a briefcase Included with purchase of LifeChoice POC 3 hour external battery Extended time battery for more mobility Comes XYC102 with battery belt carry case Included with purchase of LifeChoice POC Extra small waist belt strap for external S battery pack Included with purchase of LifeChoice POC XYC103AC 10 3m AC and DC power adapters Used to charge and run the LifeChoice POC simultaneously Used at home or in the car RV motor boat etc Included with XYC104DC purchase of LifeChoice POC 6 1 8m 7 2 1m standard single Goo lumen cannula Included with purchase of LifeChoice POC n Accessories adapters and cables other than those specified with the exception of adapters and cables sold by the manufacturer of the medical electrical equipment as replacement parts for internal components may result in increased emissions or decreased immunity of the Model XYC100 Model Number XYC100 Includes unit 7 5 w x 3 125 d x 9 5 b 4 9 pounds 4 way carry case which can be used as a convertible backpack over the shoulder strap briefcase or waist pack 5 hours of battery time AC and DC adap