Home
        UREA/DEF DC Transfer Pump Kit USER`S MANUAL
         Contents
1.       UREA DEF AC Transfer Pump Kit MODEL NUMBER  USER   S MANUAL 10302506  amp  10302507          K  DIAGRAM AND PARTS LIST       UREA DEF DC Transfer Pump Kit  USER   S MANUAL                                                             No  Description Qty No  Description Qty  1 Nozzle 1 5 O ring 2  2 Hose clamp 3 6 Pump 1  3 Delivery hose 1 7 Nut 2  4 Hose tail 2 8 Suction hose 1  PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION  F   Lack of electric power Check the electrical connecting  The Motor is not turning  Motor Problems Contact the Service Department  The motor turns slowly when starting Low voltage in the electric power line Bring the voltage back within the anticipated limits  Low level in the suction tank Refill the tank  Filter clogged Clean the filte       Lower the pump with respect to the level of the tank    Excessive suction pressure K   A  p  or increase the cross section of the tubing       High loss of head in the delivery circuit  working with    the by pass open  Use shorter tubing or of greater diameter                                                       By pass valve blocked Dismantle the valve  clean and or replace it   Low or no flow rate Air entering the pump or the suction tubing Check the seals of the connections  A narrowing in the suction tubing nea suitable for working  under suction WARNING  read carefully and understand all INSTRUCTIONS before operating   Failure to follow the safety rules and other basic safety precautions may result in serious
2.   Low rotation speed Check the voltage at the pump  Adjust the voltage personal injury   and or use cables of greater cross section  ae tubing is resting on the bottom of the Raise the tubing  Cavitation occurring Reduce suction pressure MODEL NUMBER  10302506  10302507  Increased pump noise Irregular functioning of the by pass Dispense fluid until the air is purged from the by pass  Leakage from the pump body Diaphragm damaged Check and replace the diaphragm       3 of 3 REV 02 27 14                UREA DEF AC Transfer Pump Kit    USER   S MANUAL    A  MACHINE DESCRIPTION       PUMP  Self priming  volumetric  diaphragm pump  equipped with by pass valve        MODEL NUMBER    10302506  amp  10302507    MOTOR  Asynchronous motor  single phase  2 pole  closed type  protection class IP55 in conformance with EN 60034 5 86 regulations     self ventilated        B  TECHNICAL DATA       B1  Configuration                Item No  Pump Model Voltage Suction Hose Delivery Hose Nozzle Flow Meter  10302506 17550250 12V 1 5M 6M Manual N A  10302507 17550253 24V 1 5M 6M Manual N A                                  C  OPERATING CONDITIONS       C1  ENVIRONMENTAL CONDITIONS  TEMPERATURE  Min  10  C  14  F   Max   60  C 140  F   RELATIVE HUMIDITY  Max  90     ATTENTION   The temperature limits shown apply to the pump components and must be respected to avoid possible damage or malfunction   C2  ELECTRICAL POWER SUPPLY  1 During installation and maintenance  make sure that the electric supply li
3. aracteristics   Loosening of the connections  threaded connections  flanging  gasket seals  can cause serious ecological and safety problem   Check all the connections after the initial installation and on a daily basis after that   Tighten the connections  if necessary        F  DAILY USE    a  If using flexible tubing  attach the ends of the tubing to the tanks  In the absence of an appropriate slot  solidly grasp the delivery tube  before beginning dispensing   b  Before starting the pump  make sure that the delivery valve is closed   dispensing nozzle or line valve    c Turn the ON OFF switch to ON  The by pass valve allows functioning with the delivery closed only for brief periods   d  Open the delivery valve  solidly grasping the end of the tubing   e  Close the delivery valve to stop dispensing   f When dispensing is finished  turn off the pump     ATTENTION     Function with the delivery closed is only allowed for brief periods  2 3 minutes maximum    After using  make sure the pump is turned off        G  PROBLEMS AND SOLUTIONS       H  MAINTENANCE    All models are designed and constructed to require a minimum of maintenance    In any case always bear in mind the following basic recommendations for a good functioning of the pump     On a weekly basis  check that the tubing joints have not loosened  to avoid any leakage      On a monthly basis  check the pump body and keep it clean of any impurities      On a weekly basis  check and keep clean the line suction filte
4. hat the machine has not suffered any damage during transport or storage      Clean the inlet and outlet openings  removing any dust or residual packing material      Make sure that the motor shaft turns freely      Check that the electrical specifications correspond to those shown on the identification plate           1 of 3       UREA DEF AC Transfer Pump Kit MODEL NUMBER    USER   S MANUAL    10302506  amp  10302507             ATTENTION    THE MOTORS ARE NOT OF AN ANTI EXPLOSIVE TYPE  Do not install them where inflammable vapours can be present   E3  CONNECTING    Before connection  make sure that the tubing and the suction tank are free of dirt and thread residue that could damage the pump and  its accessories     Do not use conical threaded joints that could damage the threaded pump openings if excessively tightened   Step 1  SUCTION HOSE     Connect the 1 5M Suction hose by the Hose tail   8  and Clamp   12  to the inlet of the pump   Step 2  DELIVERY HOSE     Connect the 6M Delivery hose by the Hose tail   8  and Clamp   12  to the outlet of the pump or the flow meter   Step 3  FLOW METER  Optional      Connect the flow meter by the Elbow   9  to the outlet of the pump   Step 4  NOZZLE    Connect the dispensing nozzle by the Clamp   12  to the delivery hose   E4  DISPENSING  After installation the completed pump system as picture indicated  connect the power supply  start dispensing     ATTENTION     It is the installer   s responsibility to use tubing with adequate ch
5. nes are not live   2  Always turn off the switch before supplying electrical power   3  Check the correct rotation direction of the DC pump  If it is inverted  check the polarity of the connection cable   a  RED cable  positive pole      b  BLACK cable  negative pole        ATTENTION   Power from lines with values outside the indicated limits can damage the electrical components   C3  WORKING CYCLE  1  Extreme operating conditions with working cycles longer than 30 minutes can cause the motor temperature to rise  thus damaging the  motor itself   2  Each 30 minute working cycle should always be followed by a 30 minute power off cooling phase   3  MAXIMUM BY PASSING TIME  3 MINUTES   4 DO NOT RUN DRY OVER 30 SECONDS     ATTENTION   Functioning under by pass conditions is only allowed for brief periods of time  2 3minutes maximum    C4  FLUIDS PERMITTED  PERMITTED    Chemical products  Urea  weak acid  amp  weak alkaline fluid etc     Water       D  MOVING AND TRANSPORT       Given the limited weight and size of the pumps  see overall dimensions   moving the pumps does not require the use of lifting devices   The pumps were carefully packed before shipment  Check the packing material on delivery and store in the dry place        E  INSTALLATION       E1  DISPOSING OF THE PACKING MATERIAL    The packing material does not require special precautions  not being in any way dangerous or polluting   Refer to local regulations for its disposal    E2  PRELIMINARY INSPECTION     Check t
6. r      Ona monthly basis  check that the electric power supply cables are in good condition        1  NOISE LEVEL    Under normal working conditions the noise emission from all models does not exceed the valve of 80 db at a distance of 1 meter from  the electric pump        DISPO OF CONTAMINATED MATERIA       In the event of maintenance or demolition of the machine  do not disperse contaminated parts into theenvironment   Refer to local regulations for their proper disposal           2 of 3       Size  145x210mm    REV 02 27 14    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
AVAYA T3 Classic  CABCLONE  4 - Haas Automation® Resource Center  Powermate PM0535001 Parts list  Antec NP-100 Notebook Power Adapter    商 品 企 画 書 飛ばし屋養成ギブス S-Mサイズ  ¡atención! - Fujitsu manual server  1 Inhaltsverzeichnis  zoopa Thunder #01 - ACME the game company    Copyright © All rights reserved. 