Home

Manual - SLE Projects

image

Contents

1. The stylishly modern and unassuming exterior of AEDI WASH GLOBUS houses state of the art RGBW LED technology and made using the highest guality materials and construction methods Bringing the flexibility to outdoor S E application this powerful lighting fixture is ideally suited to AW use in landscape and building illumination and IP66 ensures safe operation in even the most demanding areas With mud integral built in AC DC power supply of 230V AC 3 TECHNICAL SPECIFICATIONS Features P66 rated LED Spotlight with a saturated color mixing effect via lens specially designed to provide outstanding light output Proper thermal management with active cooling system and heavy duty design to ensure reliable performance under harsh environment Featuring 4pcsx10W CREE LEDs for excellent color mixing With Photocell light sensor feature units can light up automatically when the environment is getting dark Anice design to put diffusion filter for changing beam angles LED touch panel display for easy set up navigation It comes with great built in shows fade without DMX control Perfect for illumination of building facade hotels landscapes theme park and more Mounting Manual Tilt Adjustable Bracket Optical systems 10 16 30 Light Source 4x10 W Multichip RGBW CREE LEDs LED color variants red green blue neutral white 4000 K Lumen Output gt 1253 Im Input Voltag
2. operates moist smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture e Clean with lint free cloth using normal glass cleaning liquid e Always dry the parts carefully e Clean the surface at least every 30 days Version 1 0 Specifications are subject to change without notice 15 Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 amp Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements SLC WWW SLEPROJECTS COM 2014 All specifications subject to change without notice 17
3. SLC BUILDING PROJECTOR AEDI WASH GLOBUS 16 MC User Manual Please read the instructions carefully before use Version 1 0 CONTENTS DOA PY UNS PRU PION asecececcesereceocctevetsccececcnceceuncccasseccoccisnchissesecccccctecsescosscasseass 2 3 TECHNICAL SPECIFICATIONS wosccesecdscccccccsccesesccceccsscccesecdascessedaccosescesseccsesceees 4 i CESSORI eoa REAA EEEE 5 SHOW TO SET THE FIXTURE su 5 SE CONTROL PANEL uses secsnnvecceseseceseconseucscscaseczavveesesovsccssewssseeeavnsces 5 3 2 MAIN BU N BIN Sccccecescssivesdncesesedsnnrecscscesscoseesessiacusesustuesesuescesesesiavseceieceseese 6 6 HOW TO CONTROL THE UNTT 0 000000000000000000000000000000 000000000000 000 0002000000 10 0 1 D MX cont olle een aaa AR 10 6 3 DMX 512 CON DS in AU 1 1 VRSPRSRANHEENREEUERRERBENE ERS SEUBEUEREEREPORRIEUREEUEUEEEFEREEEEUEEDSSEREEEEREE 12 8 TROUBLESHOOTING 5ssaaisaanmassasaasestaassanaks ukauukntaaooaus0s toskaa auaNNNNENNONVANANOOSTKSKSNUNSSS 14 9I FIXTURE CLEANING AND MAINTANCE 0008 15 1 SAFETY INSTRUCTION A Please read the instructions carefully which includes important WARNING information about the installation operation and maintenance e Please keep th s User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet AA AAA A DANGER DANGER WARNING WARNING WARNING WARNING Refer Safety hazard Hazardous Fire hazard LED light Burn
4. also cleaning fixtures regularly e DONOTallow children to operate the fixture e DONOT touch any wire during operation as there might be a hazard of electric shock e Avoid power wires together around other cables e Replace fuse only with the same type e In the event of serious operating problem stop using the unit immediately e The housing and the lenses must be replaced if they are visibly damaged e DONOT open the unit as there are no user serviceable parts inside Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical center for any service e Disconnect the mains power if the fixture is not used for a long time e DO use original packing materials to transport it again e To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture e DO NOT look directly at the LED light beam while the fixture is on If you use a 230V 50Hz power supply DO NOT connect in series more than 20 units use another main supply for the next 20 fixtures If you use a 120V 60Hz power supply DO NOT connect in series more than 10 units use another main supply for the next 10 fixtures The manufacturer does not take responsibility f the device is operated under conditions other than described in this manual The product may suffer damage and the guarantee becomes void 2 ABOUT THE PRODUCT
5. button Channel mode Select the Lf press the ENTER button and the display will blink Use the DOWN and UP button to select the lt 4 Channels Red Green Blue White Met 5 Channels Red Green Blue White Dimmer or MU 7 Channels Red Green Blue White Color Dimmer Strobe Mode Once selected the reguired mode press the ENTER button to store or automatically exit menu mode without any change after one minute To go back to the functions without any change press the MENU button Show mode Select the Shiol press the ENTER button and the display will blink Use the DOWN and UP button to select the show 1 5159 show 19 Once select press the ENTER button to setup press the ENTER button gt E O will blinking on the display use DOWN and UP button adjust the fade time 0 255 press the ENTER button to store and BEL O will blinking on the display use the DOWN and UP button adjust the white time 0 255 press the ENTER button to store or automatically return to the main functions without any change after one minute To go back to the previous functions without any change press the MENU button BI Aled Blackout mode Select the liL Fic press the ENTER button and the display will blink Use the DOWN and UP button to select the blackout or normal Once selected press the ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the functi
6. e 100 240V AC 50 60Hz Daisy Chain System Wiring Dimmable Electronic Control Gear USITT DMX 512 A Power Consumption Power cable connection Service lifetime Operating ambient tem Max 45 W Average consumption in color mixing mode 30 W IP rated connectors 50 000 hrs L70 25 C 20 C 40 C Materials Housing die cast aluminum Cover clear hardened glass IP Rating IP66 Dimension 343x 208 162mm Weight 3 8 kg Finishing White aluminum RAL 9006 Accessories DMX controllers AEDITEMPA ATTACA amp AEDITEMPA LIBA 4 ACCESSORIES Power Extension Cable 1 2 5 10 m DMX Extension Cable 1 2 5 10 m 5 HOW TO SET THE FIXTURE 5 1 CONTROL PANEL W n 1 DISPLAY To show the var ous menus and the selected functions 2 BUTTON 2 MENU To select the programming functions 3 DOWN To go backward the selected functions 4 UP To go forward in the selected functions 5 ENTER To confirm the selected functions 3 DMX IN Water
7. hazard Hot to user manual Risk of severe voltage Risk of emission Risk of surface Do not injury or death lethal or severe eye injury touch electric shock Caution e All fixtures are intact from the manufacturer please operate follow up the user manual artificial fault are not under guarantee repair e Unpack and check carefully that there is no transportation damage before using the unit per first time e Please install and operate by qualified technician e Use safety chain when fixes the unit e The unit must be installed in a location with adequate ventilation at least 50 cm from adjacent surfaces e Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit e It s important to ground the yellow green conductor to earth in order to avoid electric shock e Maximum ambient temperature Ta 40 C DO NOT operate it where the temperature is higher than this e DO NOT connect the device to any dimmer pack e Make sure there are no flammable materials close to the unit while operating as it is fire hazard e Look over power wires carefully replace immediately if there is any damage e Unit surface temperature may reach up to 60 C DO NOT touch the housing bare hand during its operation e Avoid any inflammable liquids water or metal objects entering the unit Once it happens cut off the mains power immediately e DO NOT operate in dirty and dusty environment
8. its can receive DMX signal Press the MENU button up to when the cdon is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds later To go back to the functions without any change press the MENU button again Please refer to the following diagram to address your DMX512 channel for the first 4 units 4 channels mode N N 5 channels mode u 4 7 channels mode mm i Li 6 3 DMX 512 Configuration 4 5 7 Channels Mode DMX512 Configurations A Channels Mode 5 Channels Mode 5ChannelsMode Ch Ch4 Green i 7 Channels Mode Red 259 100 Green chs 255 0 100 0 248 255 Preset color32 240 247 Preset color31 232 239 Preset color30 224 231 Preset color29 217 223 Presetcolor28 209 216 Preset color27 201 208 Preset color26 194 200 Preset color25 186 193 Preset color24 178 185 Preset color23 170 177 Preset color22 163 169 Preset color21 155 162 Preset color20 147 154 Preset color19 140 146 Preset color18 132 139 Preset color17 124 131 Preset color16 116 123 Preset color15 109 115 Preset color14 101 108 Preset color13 093 100 Preset color12 085 092 Preset color11 078 084 Preset color10 070 077 Pre
9. m for self test To go back to the functions press the MENU button again LED Display Select the LEI press the ENTER button and the display will blink Use the DOWN and UP button to select LED display on or LED display off 20 seconds after exit menu Once select press ENTER button to setup or exit menu mode without any change after one minute Back to the functions without any change press MENU button again Temperature Select the lt PPI press the ENTER button and the display will show the current running temperature of the fixture To go back to the functions press the MENU button again Fixture Hours Select the Et Gl press the ENTER button and the display will show the running time of the fixture To go back to the functions press the MENU button Firmware version Select the El press the ENTER button and the display will show the version of software of the fixture To go back to the functions press the MENU button again 6 HOW TO CONTROL THE UNIT You can operate the unit by DMX controller No need to turn the unit off when you change the DMX address as new DMX address setting will be affected at once Every time you turn the unit on it will show on the display After that the unit will be ready to receive DMX signal or run the built in programs 6 1 DMX Controller Use universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the un
10. ons without any change press the MENU button FS S Manual Mode Press the MENU button up to when the Is shown on the display Press the ENTER button and the display will blink Use the DOWN and UP button to select the Red Green 1 Dimmer or Strobe Once selected press the ENTER button to setup then use the DOWN and UP button to adjust the value 0 255 or automatically exit menu mode without any change after one minute To go back to the functions without any change press the MENU button White Balance Press the MENU button up to when the Is showing on the display Pressing the ENTER button and the display will blink Use the DOWN and UP button to select the Red Sc E Green or Blue mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after one minute To go back to the previous functions without any change press the MENU button Display Inversion Select the SR press the ENTER button and the display will blink Use the DOWN and UP button to select the on normal or Ef inverse Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after one minute To go back to the previous functions without any change press the MENU button ey Auto Test Select the EB SE press the ENTER button and the unit will run the built in progra
11. proof 3 pin XLR connectors for DMX 512 operation 4 POWER IN Water proof connectors for power input 5 POWER OUT Water proof connectors for power output 6 DMX OUT Water proof connectors for DMX 512 operation with 3 pin XLR plug 5 2 MAIN FUNCTIONS To select any functions press the MENU button until the required one is shown on the display Select the function by the ENTER button and the display will blink Use the DOWN and UP button to change the mode Once the reguired mode has been selected press the ENTER button to setup or it will automatically return to the main functions without any change after idling one minute Back to the functions without any change press the MENU button The main functions are shown below DMX Address 4 Mode R G B W 4D Mode R G B W Dimmer C 4C Mode R G B W Color Dimmer Strobe Show1 16 Blackout Mode Manual Test White Balance Photo Cell Intensity Time Setup Display Inversion Auto Test LED Display On Wed LED Display Off eent Temperature Fine S Fixture use time Firmware Version DMX 512 Address Setting Select the Addr press the ENTER button and the display will blink Use the DOWN and UP button to adjust the DMX512 address between 1 and 512 Once the address has been selected press the ENTER button to save or automatically exit menu mode without any change after one minute Back to the previous functions without any change press the MENU
12. r The address number is between 0 511 usually O amp 1 are equal to 1 The end of the DMX 512 system should be terminated to reduce signal errors 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin 4 Pin 5 Not 13 used 8 TROUBLESHOOTING Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting Possible Cause The unit does not work no light Incorrect power cable The unit does not respond properly to the DMX control Check the connection of power connection Incorrect mains voltage Measure the mains voltage on the main connector Incorrect DMX cable Check DMX connectors and connection cables to see if link properly Repair or replace damaged wires Incorrect address assignment to Check the addresses of the units the units and the protocol settings Unfinished data connection Insert a terminal plug in the output jack of the last unit of the connection It has been set up an operating Check the operating mode set up mode different from the DMX mode used Try to use another DMX controller 9 FIXTURE CLEANING AND MAINTANCE The cleaning must be carried out periodically to optimize light output Cleaning freguency depends on the environment in which the fixture
13. set color9 062 069 Preset colors 055 061 Preset color7 047 054 Preset color6 039 046 Preset color5 031 038 Preset color4 024 030 Preset color3 016 023 Preset color2 008 015 Preset color1 001 007 OFF OPEN id 132 139 16 131 8 15 255 248 255 OPEN 240 2477 RANDOM STROBE 232 239 OPEN SLOW CLOSE 190 2311 FAST OPEN 182 189 L OPEN SLOW OPEN 140 161 FAST CLOSE 0 7 0 OFF 12 7 DMX512 CONNECTIONS l 2 SS 6 6 SS 6 6 o 6 SSO NIE POWER OUT En DMX OUT 00 8800 DMX512 Controller COMMON DMX INPUT Termination reduces signal errors and to avoid signal transmission problems and interference Itis always advisable to connect a DMX terminal Resistance 120 ohm 1 4W between pin2 DMX and pin3 DMX of the last fixture If you use a controller with 5 pins DMX output you need to use a 5 to 3 pin adapter cable Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of the next unit The cable cannot branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units powers is disconnected Each lighting unit needs to have an address set to receive the data sent by the controlle

Download Pdf Manuals

image

Related Search

Related Contents

  gerrard manuel d`instructions directives de sécurité  製 品 仕 様 書  Multi-Camera Array User's Guide    

Copyright © All rights reserved.
Failed to retrieve file