HMGWIN3000 User manual

image

Contents

1. Select the copy requirements in the lowest box in the drop down menu Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 10 m Define the folder in which the recording will be saved by clicking on the right hand side of the window m Now click the little arrow in the centre of both boxes the recording is saved m Close the HMG 3000 Manager to continue working with HMGWIN 3000 Deleting a recording by HMG m Click on the Units dialogue box and select HMG3000 Manager from the drop down menu A new window for HMG 3000 Manager opens Click on Recordings on the left side of the window All of the recordings stored in the HMG 3010 are shown on the left Select one or more recordings from the list Click on Delete in the line under the recordings Close the window HMG 3010 to continue working with HMGWIN 3000 4 2 2 Opening a measurement curve already saved on the PC To open a file which has already been saved on the PC click on the File dia logue box and select Open in the dropdown menu You also have the option of clicking directly on Open at the bottom left of the screen Select the required recording in the relevant folder file extension herf To open recordings made with a previous version of the HMG e g HMG 2020 select Legacy formats as the file type in the dropdown menu file extension hmg cur pro To open a recording generally made b
2. Click on the Graph dialogue and select View in the dropdown menu and Key board Navigation in the submenu or select Keyboard Navigation at the bottom of the screen Navigieren am unteren Rand ist nun fettgedruckt Using the keyboard arrow keys you can shift the viewing area to the right left up and down Every time you press an arrow key the viewing area is shifted by one grid unit in the relevant direction If you press the Shift key at the same time every time you hit the or key the time axis of the graph is enlarged or reduced respectively This corresponds to a zoom function but for the time axis only If you press the Shift key while hitting the or key you can change the scaling of the Y axis This corresponds to a zoom function but for the Y axis only 4 4 12 Note Click on the Graph dialogue box and select Other in the dropdown menu and Remarks in the submenu or select Remarks at the bottom of the screen Remarks is now highlighted at the bottom of the screen When you move the mouse over the graph the mouse pointer turns into a square con nected with the handle by a line Using the handle click on the approximate position you would like to insert a remark A Remark window opens It is subdivided into three parts text style and anchor Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 15 Remark text gt The remark text T 96V automatica
3. be se lected by clicking on the tab name General tab appears first when opening the window The recording time and the current output range are indicated The current output range can be changed manually by entering other time values gt You can also choose whether the time or the measurement range of a sensor is to be scaled along the X axis e g for a P Q diagram By clicking the checkbox for Left Y axis and Right Y axis you can de termine which channels are to be displayed and scaled on the Y axis right or left hand side of the graph Individual measurement channel tabs Under Designation you can give the measurement channel a name e g sys tem pressure if the system pressure of an equipment item was measured in this measurement channel using a pressure transducer gt The following can be entered manually in the second section the full indica tion range the range shown when selecting Full indication range and the current indication range range currently shown gt Third section the type of display can be set and whether or not the associat ed measurement series is to be displayed The measurement series is hid den when you deactivate the checkbox after Show measurement series i e click on the checkbox so that the checkmark disappears You can also select the color for the measurement series from a list You can access the list by clicking on the arrow button next to the color You can selec
4. curve with trigger m Choose the following settings in the dropdown menus of the Start recording menu Recorded data Save in PC Recording Measurement curve with trigger Measurement channels i e A B Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 28 Sampling rate 1ms Recording time 10 sec Trigger settings i e T1 with the settings Pre post trigger 50 50 Automatic mode activated Remark Training example When you have finished entering your settings please click on Start The Save recording as window opens Select a folder in which you would like to save your recordings define a file name and click on Save You can now see the current progression of the curve on the screen As the Pre Post trigger has been set to 50 50 now 50 of the past is depicted in the graph If the trigger event occurs a measurement recording is completed saved under the before determined name and restarted To zoom in a portion of the recording please click on Zoom in at the bottom of the screen Zoom in is now highlighted When you move the mouse over the graph the mouse pointer turns into a magni fying glass with a minus sign To zoom in on one of the grid squares click on it and hold the left mouse button down and mark the grid square you wish to zoom in After releasing the left mouse button the marked squares are displayed in a larger format By clicking on
5. e To save all changes in all files click on the File dialogue box and select Save all in the dropdown menu or click on Save all at the bottom left of the window e f all recordings have been previously saved saving occurs without any new window opening e f one or more of the recordings have not yet been saved the Save recording as window opens 4 6 6 Export The export function enables you to save measured data in a format that can be exported to a spreadsheet program e g Excel for example e To export a file click on the File dialogue box and select Export in the dropdown menu or click on Export at the bottom left of the window e Now the Export data window opens e Select the time range to be exported m Whole time range m Displayed time range e Select the channels to be exported m All channels m Displayed channels e Decide how unit of measurement should be displayed m Without unit or m Separate row e Select the data format in which the recording is to be saved m Text separated by tabs m CSV separated by commas m Formatted text separated by spaces m User defined ASCII ANSI Format e Select the delimiter characters for User defined ASCII ANSI Format only m No quotation marks m Single quotation marks m Double quotation marks e Select the separators for User defined ASCII ANSI Format only m Space
6. ee tate ta eres a oda trae es 29 Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 5 1 General information The PC software HMGWIN 3000 can only be used in con junction with the HYDAC Portable Data Recorder HMG 3010 or to process evaluate measurements recorded using the HYDAC portable data recorders We cannot accept any liability or provide warranty outside this field of application Our General Conditions of Sale and Delivery and the Special Conditions of Sale and Delivery for Software Products Freeware apply to the use of the HMGWIN 3000 These Terms and Conditions can be viewed on our website http Awww hydac com AGB click Company Legal information or are available on request as a PDF file 1 1 Copyright laws The dissemination and or reproduction of this document as well as the exploitation and communication of its content is not permitted unless specifically authorized Contraventions are liable to compensation All rights reserved 1 2 Note on Warranty This manual was compiled with the greatest possible care Nevertheless errors or deviations cannot be excluded and for this reason we assume no responsibility for the complete accu racy of the content In view of the fact that despite intensive endeavors errors can never be completely avoided we welcome tips and suggestions for improvement at any time 2 Safety 2 1 General Safety Precautions Fo
7. m User defined ASCII ANSI Format Select the delimiter characters for User defined ASCIVANSI Format only m No quotation marks Single quotation marks H Double quotation marks Select the separators for User defined ASCII ANSI Format only Space Tab List separator Other Select the column width for User defined ASCII ANSI format only Without fixed width m Automatic optimum width m Fixed column width Input directory directory containing all data to be exported m Click on button next to input box m A window opens enabling you to browse for the folder Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 24 Export folder m Click on button next to input box m A window opens enabling you to browse for the folder Click on Ok to export the file Click on Cancel to cancel the action 4 6 8 Print To print a recording click on the File dialogue box and select Print in the dropdown menu or click on Print at the bottom left of the window A window for Print opens In the upper part you can select wether you want to print or generate a PDF file In case you choose to generate a PDF file select the path in which you want the re cording to be saved You can Keep the name of the recording as the file name or click on the arrow but ton and select Ask for new file name from the dropdow
8. on the settings that you wish to delete f you click on Delete all the files highlighted in blue will be deleted Click on Back to get back to the settings menu e Close the HMG 3000 Manager to continue working with HMGWIN 3000 4 7 2 5 Starting a Recording It is possible to record measurements from your PC e To start a recording from your PC click on the Units dialogue box and select HMG3000 Manager from the drop down menu e A new window for HMG 3000 Manager opens e Click on Start recording Except the Recorded data menu item in the following you will find the same setting options as in the HMG 3010 device itself Details can be found in the HMG 3010 man ual see section Start recordings In the Start recordings item the dropdown menu offers you the options of Save in HMG and Save in PC m When choosing Save in HMG the measurement will be recorded and saved in the HMG and immediately transmitted to the PC where it will be saved under the file name that has been defined before m When choosing Save in PC the measurement from the sensors will be immedi ately transmitted from the HMG to the PC and will be saved here under the file name that has been defined before Furthermore you can see the running meas urement as an Online graph on the PC screen In this recording process the smallest possible measuring rate is 1ms e Example for a recording in Save recorded data in PC using Measurement
9. superimpose two measurement curves click on the Edit dialogue box and select Curve overlay in the dropdown menu Note possible only for curves with the same sampling interval The Wizard for Overlay opens in a new window You are now asked to select a 2nd recording i e the curve to be superimposed on the curve currently opened Click on the arrow button to get a list of all open curves recorded using the same sam pling rate To see all the curves possible click on the arrow button next to the name The list is empty if no curves with the same sampling rate are open Click on the curve you would like to superimpose then click on Next in the bar at the bottom of the window The second recording is opened in the same window as the original recording and a prompt for coordinating the time of the second recording appears in the wizard Shift ing can only be done along the time axis The recording can be adjusted roughly using the mouse and clicking on the scrollbar keeping the left mouse button pressed and shifting the recording to the approximate position desired To position the recording precisely click on the arrow buttons to the right gt and left of the scrollbar until the second recording is positioned as desired To overlay the curves click on Finish in the bar at the bottom of the window Click on Cancel to cancel the overlay Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGW
10. the approximate point in time for which you would like to know the measured values An indicator line appears vertically on the time axis on which the values of the individu al curves are marked by squares The time and the individual measured values are appropriately color highlighted on the axes If you hold the left mouse button down you can drag the line along the time axis whereby the values are displayed During tracking you jump from one measured value to another The indicator line can also be moved along the time axis by clicking on the Up Down Arrow buttons lower right of screen underneath Measured Value No or by press ing the Up Arrow or Down Arrow keys on the keyboard By doing this you track each measured value Clicking on another position in the graph will move the indicating line to that point 4 4 4 Tracking the difference Click on the Graph dialogue box and select Evaluation in the dropdown menu and Track difference in the submenu or select Track difference at the bottom of the screen Track difference is now highlighted at the bottom of the screen When you move the mouse over the graph the mouse pointer turns into a dual vertical line Click left mouse button on the first approximate point in time for which you would like to know the measured values Pull the double line apart as far as the second time point for which you wish to know the measured values Status 2010 05 22 HYDAC ELECTRONIC G
11. the remark text or manually enter another anchor time click on the 3 handles in the lower right corner The remark box opens again Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 16 OK Cancel and Delete appear in the bar at the bottom of this window OK apply changes gt Cancel close window and discard changes gt Delete delete the entire remark 4 4 13 Remarks List e Click on the Graph dialogue box and select Other in the dropdown menu and Remarks list in the submenu or select Remarks list at the bottom of the screen e A window with the remark list opens e All remarks are listed along with the particular X axis allocated their anchor their posi tion on the X axis time and the relevant remark text e The entire text of the blue highlighted remark appears in the lower box e Click on Delete in the bar beneath this window to delete the blue highlighted remark e Click on OK to close the window with the remarks list Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 17 4 4 14 Settings Click on the Graph dialogue box and select View in the dropdown menu and Settings in the submenu or select Settings at the bottom of the screen You can also move the mouse into the area of the axis an click on the blue highlited area A window with the settings is opened containing a number of tabs each tab can
12. them Release the left mouse button to display the view last shown in the overall graph in the framed area 4 4 7 Panning Click on the Graph dialogue and select View in the dropdown menu and Pan in the submenu or select Pan at the bottom of the screen Pan is now highlighted at the bottom of the screen When you move the mouse over the graph the mouse pointer turns into a hand Click on the graph and hold down the left mouse button Using the mouse now shift the image in the required direction Release the mouse button Panning is only done in whole grid units 4 4 8 Full view Click on the Graph dialog and select View in the dropdown menu Full view in the submenu or select Full view at the bottom of the screen The graph now shows the entire time and amplitude range of the measurement 4 4 9 Automatic scaling Click on the Graph dialog and select View in the dropdown menu Scaled in the submenu or select Scaled at the bottom of the screen The scale settings selected see section 4 4 10 are applied to the current recording Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 14 4 4 10 Scale settings Click on the Graph dialog and select View in the dropdown menu Scaling in the submenu or select Scaling at the bottom of the screen Selecting the resolution type and scaling type refers to the default scale settings A new window for Scale setting
13. then click on Edit Now you can restart searching your HMG and reconnect as described in section 3 4 4 7 2 Actions From your PC you can display and administrate the current measured values from your HMG 3010 In addition you can edit the sensor settings trigger settings redordings set tings default measuring units and display settings You have different options to save the settings or to retreive saved settins Furthermore you can start recordings from your PC 4 7 2 1 Display measured values To view current measured values of the HMG see section 4 1 4 7 2 2 Recordings e You have an overview of your saved recordings in the HMG as well as from the PC re cordings e Copy Open or Delete recordings see 4 2 4 7 2 3 Settings e To change save or retreive the settings in the HMG click on the Units dialogue box and on HMGS3000 Manager in the dropdown menu e A new window for HMG 3000 Manager opens e Click on Change settings on the left side of the window n the right box the different changes which can be made to the settings are shown Here the same setting parameters as in the HMG 3010 device itself compare manual HMG 3010 are possible Tochange the sensor settings click on Settings of measuring channels nthe right box now the channels with their settings appear You can activate or deactivate the channels To carry out changes please click on the right measuring range settings dis pl
14. Full view the full range is displayed again By clicking Settings a new window will open gt You can choose whether to scale the time or one of the sensors at the x axis Thus a p q diagram can be displayed online By clicking the checkbox for Left Y axis and Right Y axis you can deter mine which channels are to be displayed and scaled on the Y axis right or left hand side of the graph gt In the lower section you can show or hide individual channels By manual en try of the Current display range you can assign different y scalings to the individual channels Apply means the made changes can be applied without closing the win dow gt Clicking OK leads to application of the made changes and closes the win dow gt Cancel closes the window and discards the changes If you select Cancel recording during the running measurement the measure ment is interrupted and will be restarted again afterwards To finish the recording click on End automatic and then Cancel recording in case no more trigger event is expected to occur 4 7 3 Extras You have the option of updating the HMGWIN 3000 firmware for your HMG 4 7 3 1 Update for HMG 3010 Click on the Units dialogue box and select HMG3000 Manager from the drop down menu In the opened window HMG3000 Manager click on the Extra dialogue box and then proceed to the dropdown menu item Update firmware A new window for the upda
15. G9 ELECTRONIC PC Software HMGWIN 3000 User Manual Translation of original instructions Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 2 Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 3 Table of Contents T General informati n iei ve da A Ila ERAS CURED DH EAN LEXIC o 5 11 Copyright AW t 5 1 2 Note on Warranty 0 ii dosi oe ised nae lol edie 5 2 Sale duisi AAA IA A DEUS EUH NINE RH CE DEP 5 NEU A 6 3 1 Hardware and Software Requirement ccccccccssseesseeeeeeeeeeeseeeeeeeeeeeeeeeeeneseeneeees 6 3 2 USB Driver Installation onion ere tone eodera rot u eR cavedacetecdenussatadeaesscee 6 3 3 Installation HMGWIN 3000 eeeeeeeeeeeeeeeeeeeeee enne nennen nnn nnne nennen 6 3 4 Starting the DFogfFam eene execs ced Eae etd Fue tacere foeni testa 7 3 5 Setting up Connection with HMG 3010 cese 7 3 5 1 Communication error uie roce etapa ele coe oou usd dee deo e ir tera eer aet dena dede 8 4 Using HMGWIN ssssscssessssesscsssscsssscsssscsssecsssscssssssnsscsnsscssscensscsssscssscsnssesnsscesssees 9 4 1 View current measured values of HMG 3010 in HMGWIN 3000 9 4 2 Retrieving a Measurement Curve ceeeeeeeeeeeeeeeeeeen nnne nnne nnne 9 4 2 4 Retrieving and deleting a file from
16. HMG 3010 in HMGWIN 3000 sess 9 4 2 2 Opening a measurement curve already saved on the PC sssssssssssss 10 4 2 3 Retrieving an open file oon oocnnnncccnnnnnocnccnnnonccnnnnanccnnnnencnnnnnennnnnnne nan nnnne nn cn nana nan nana nannnnns 10 43 Dialogue box View cid ss 11 44 Dialogue box Graphic is 11 E AO 11 4 4 2 M asu ring differeriCe et agente RR REED Ue HEC dee ee ep ee 12 LAS TIaCKIDG a cr ETE eee ee Tt REI E eee 12 4 4 4 Tracking the difference ooomnocccnnnnoccnnnoccnccnoncnncnnonnnncnnonrnnnn non nnnn naar nrn nennen nennen eren nenne nnn 12 4 4 5 r ZOOMMMG Dro eR ERES EROS o RECEN Eel ou de eR 13 44 6 ZOOMING QUE io eset ER IIO RPG ibi ep M 13 SAT PANMI oieee andi eame tree ev eerte eina e ter nane eta ee ee dva 13 CREME Eu Dc ea enya east enna ennai aie ania dinate 13 4 49 Automatic Scallng enmt rana 13 44 10 A rmt ete pe tr nete Ecce Hore edet revu 14 4 4 11 Keyboard navigation secs inen ea aa aAa AARAA AA nennen nnne rne rnnt trte nnn nennen nns 14 4 4 12 NO eundo iiec tatc ie ERE E Radeon a Rae attin te eee ru ir ERR u ud 14 4413 Remarks List oerte NU eel Wel EP PR eee 16 44 14 A cue E EUER euet AE 17 4 4 15 Backwards ii nes i eter o eo eee ege eed 17 44 16 OWN e c ets Lee oer den 17 4 417 SAVONICW anto eB at eie emt tee dede lere 18 44 18 Eistsaved vIews senes eene Ee DO bene 18 4 419 Create Picture ocd estie rp Per e tee ed
17. IN 3000 Page 20 4 5 3 Time shift channels To time shift one or more channels in a measurement click on the Edit dialogue box and select Time shift channels in the dropdown menu The Wizard for Time shifting of channels opens Select the channel you wish to time shift in the dropdown menu The measurement channel can be adjusted roughly by clicking on the scrollbar keep ing the left mouse button pressed and dragging to the right or the left To position the recording precisely click on the arrow buttons to the right and left of the scrollbar or press the right and left arrow keys on the keyboard until the measurement channel is positioned as desired Click on Close to return to the main window The time axis is now marked with an asterisk time ms This means that at least one of the curves has been time shifted To undo the shifts return to the Wizard for Time shifting of channels see above Click on Delete to undo the shift of the active channel see name in upper box Click on Delete All to remove the time shift on all channels Click on Close to return to the main window 4 5 4 Add a Calculated Channel To calculate a channel from one or more measurement channels click on the Edit dialogue box and select Add calculated channel in the dropdown menu A new window opens for calculating the channel Enter the mathematical formula for the virtual channel in the formula input bo
18. MBH Part No 669847 PC Software HMGWIN 3000 Page 13 Vertical to the time axis two indicator lines will appear and in between these the measuring point distance is displayed The time and the individual differential values are color highlighted as appropriate on the axes 4 4 5 Zooming in Click on the Graph dialogue box and select View in the dropdown menu and Zoom in in the submenu or select Zoom in at the bottom of the screen Zoom in is now highlighted at the bottom of the screen When you move the mouse over the graph the mouse pointer turns into a magnifying glass with a plus sign Only whole grid squares can be magnified To zoom in on one of the grid squares click on it and hold the left mouse button down You can select one or more grid squares by dragging the mouse and drawing a rec tangle around them Release the left mouse button to zoom in on the selected portion i e the selected por tion is displayed larger within the overall graph 4 4 6 Zooming out Click on the Graph dialogue box and select View in the dropdown menu and Zoom out in the submenu or select Zoom out at the bottom of the screen Zoom out is now highlighted at the bottom of the screen When you move the mouse over the graph the mouse pointer turns into a magnifying glass with a minus sign Zooming out functions in a similar manner to zooming in Select one or more grid squares by dragging the mouse and drawing a rectangle around
19. annels are listed Select the channel to be filtered Clicking on Settings to open the channel settings window Click on OK to save any changes you might have made or Cancel to discard them By moving the arrow on the bar Filter strength with your mouse the degree of filter ing is changed Changes can be monitored in the display pane of the graph When the filter setting desired is located click on OK and the channel is inserted permanently and can be edited like any other channel Filtered channels are also al ways marked with an asterisk Click on Cancel to cancel the action without saving the changes 4 5 6 Remove channels 4 6 CAUTION 7his action cannot be undone To remove i e not just hide individual measurement channels click on the Edit dia logue box and select Remove channels in the dropdown menu A new window opens in which all the channels of the recording are listed Select the channels to be removed by clicking on the checkbox next to their name A checkmark appears in the checkbox When you have selected all of the channels to be removed click on OK at the lower edge of the window Click on Cancel to cancel the action Dialogue box File The dropdown menu of the File dialogue box contains various possibilities for retrieving saving etc recordings 4 6 1 Open To open a file which has already been saved on the PC click on the File dialogue box and select Open i
20. ayed in blue When you have carried out the desired changes click on OK to apply the changes or on Cancel to get back to the previous menu without applying the changes To apply the trigger settings click on Trigger settings In the right box now the different events with their settings appear To activate or deactivate the events click on the box behind the correspond ing event To set the event click on the appropriate blue highlighted event with its set tings Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 26 Status On the right hand side the recent settings of the corresponding trigger appear and you can make changes You also have the option of linking events Without linking each of the four events acts alone and independently as a trigger for a measurement record ing When all the trigger settings have been carried out please click on OK to apply the changes or on Cancel to get back to the settings menu without applying the changes To change the recording settings click on Recording settings In the right box now the recording settings appear By Name the name is meant under which the next measurement will be saved in the HMG 3010 Click on OK when you have carried out the desired changes and if you want to apply them Click on Cancel if you would like to get back to the settings menu without applying the changes To change the defaul
21. e left part of the window you have the following options Transparent the created picture is transparent so that the underlying picture is visible thus enabling two curves to be compared visually Copy the picture is copied to the Windows Clipboard for use in other docu ments Save opens a window for saving the picture in JPG format Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 19 4 5 Dialogue box Edit You have various options for editing and processing a curve All of the functions for this are located in the dropdown menu of the Edit dialogue box Extract recording and Curve overlay create a new measurement which is filed in the left hand box when files are open the files being named Recording X x sequential number They are not saved automatically however 4 5 1 Extract recording To create a copy of the measurement currently opened or extract a zoomed portion of the measurement click on the Edit dialogue box and select Extract Recording in the dropdown menu The measurement is filed in the left box of the open files and can now be edited with out any changes being made to the original file You can save this file under a different name of your own choosing 4 5 2 Curve Overlay Overlaying two measurement curves is useful for comparing measurements e g the measurement of a machine cycle taken three months ago compared to its current con dition To
22. e of delivery e Select the folder containing the Installation file and open the folder HMG USB driv er Depending on the equipment please open Windows 2000 or Windows XP S2KS3 Vista 7 and select the driver file contained in it CP210x VCP Win XX exe auf Follow the instructions of the Setup Wizard 3 3 Installation HMGWIN 3000 e Call up the file HMGWIN 3000 Vxx Rxx SETUP EXE in the folder HMGWIN 3000 in the Installation directory and follow the instructions of the Setup Wizard Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 7 3 4 Starting the program e f you have installed the program in the default path suggested by the Setup Wizard it is located in the Start Menu under Programs HYDAC ELECTRONIC To launch the program click on HMGWIN e When launching the program for the first time a window appears enabling you to select the user interface language German English or French To do this select the language by mouse click Confirm the setting by clicking the OK button 3 5 Setting up Connection with HMG 3010 To establish a connection with a HMG device connected to the PC click on the Units dialogue box and select Connection from the drop down menu A window for Connection opens e Click on Modify to open the window for the interface settings Make the corresponding pre selection for the port settings in the window that opens under Interface se
23. e weet teet RE ei adea tud 18 45 Blalogue box Edlt sionista 19 4 5 1 1EXtract recording sss otc a 19 4 5 2 r G rve OVerlayse siiis tete tiro tieu tcc i sete cete fase c n Died 19 4 5 3 Dimesshiftichannels itur er aoreet aotbemdemitietp m 20 4 5 4 Add a Calculated Channel sse nenne nennen nennen nnne 20 4 55 Adda filtered channel cote epe ette Doe hoe ne do ES 21 Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 4 4 5 6 REMOVE channels etd iria 21 amp 5 Blal que box AAA A 21 O metis conse ee ike auras tee Prati tal LM Dice OR 21 4 6 2 Import iiic end rie tit ende aerei emerit ed eda e eere ve eta ee ee 21 LIRE CPC 22 ABA SAVC AS EE 22 4 6 5 SAVE all tet oen e a d vies Ete ee Dd t D Eve 22 46 6 EXPO ntn ierat nt e n enit tene ont ete 22 46 7 EXPO FOEN idi ette cda e eed 23 46 8 Prin s nete ne IRR ARR RERO RR 24 4 65 95 Gl9SQ onte dei Mure ea Suet nh eee et IRL LEA oe 24 4 6 10 gt Close all 2 eie cte eate nete Rte c ed deed LAS Ree inet es Eo eed Dea 24 4 7 Dlaloque box Units ou adi 25 AGA Qonnect sui needle td 25 41 2 ACROSS suenan e Een meae pie wide ttes nette 25 47 3 SEX aS ec 0 crete come epe IDE gementes 28 49 Blalodgue DOX Extras uere iue ii aia 29 4 8 1 OPUONS 4 tiit rm A s ete tiom die usur ada 29 4 8 2 ROOP ODIOS s t o doses sin ln dels eate cte A er LR ud 29 49 Dialogue box Help iia an aac cece cack o trance roten
24. emarks of other companies are used these relate exclusively to the products of those companies Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847
25. for the curve The designations and remarks can be changed or added here 4 4 Dialogue box Graph There are many possibilities to work with or to edit a measurement curve All editing tools can be found in the dropdown menu of the Graph dialogue as well as at the bottom of the screen 4 4 4 Measuring e Click on the Graph dialogue box and select Evaluation in the dropdown menu and Measure in the submenu or select Measure at the bottom of the screen Measure is now highlighted at the bottom of the screen When you move the mouse over the graph the mouse pointer turns into a ruler Move the ruler to a point in the graph and press the left mouse button Crosshairs and the corresponding values of the intersection of these crosshairs are shown on the X and Y axis If you hold down the left mouse button you can move the crosshairs in the graph e The intersection can be shifted as follows m By moving the mouse over the crosshair you want to change parallel to the time axis or value axis of the sensors When the mouse pointer changes to a double arrow f click the left mouse button and shift the relevant axis to the point from which you need the measured value m Byclicking on another point in the graph with the ruler Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 12 4 4 2 Measuring difference Click on the Graph dialogue box and select Evaluation in the dropdown menu and Meas
26. hown or hidden when clicking again By clicking Reset Min Max values the current Min Max values are set back to zero Close the HMG 3000 Manager to continue working with HMGWIN 3000 4 2 Retrieving a Measurement Curve There are three ways of doing this You can either import a measurement curve from HMG 3010 into HMGWIN 3000 open a saved file or retrieve a file that is already open 4 2 1 Retrieving and deleting a file from HMG 3010 in HMGWIN 3000 e Open the file using the HMG 3010 Click on the Units dialogue box and select HMG3000 Manager from the drop down menu Click recordings All of the recordings stored in the HMG 3010 are shown on the left Select one or more recordings from the list Click on open in the line under the recordings All selected recordings are opened in HMGWIN 3000 and the last recording to be opened is shown in the display window the others in the left hand col umn is displayed by Recording x x consecutive numbering Close the HMG 3000 Manager Now you can work with the recording see point 4 4 and following The recording can be saved again afterwards see point 4 6 3 and follow ing e Direct saving of a file from HMG 3010 into HMGWIN 3000 Click on the Units dialogue box and select HMG3000 Manager from the drop down menu A new window for HMG 3000 Manager opens Click on Recordings on the left side of the window Select one or more recordings from the list
27. lection Select the relevant port address and Baud rate under nterface settings As an alternative you can also automatically search for HMG devices con nected to the PC under HMG3000 devices search by pressing Start gt HMGWIN 3000 indicates at which port HMG 3000 has been recognised Click on Ok to confirm the connection If a HMG has been detected click on Apply to keep this interface or on Can cel to discard the interface changes Click Refresh to update the interfaces marked under nterface selection in terms of availability Click on OK to apply the modified settings or Cancel to discard these chang es In either case you will then return to the Connection window e Afterwards click on Connect in the Device box to connect the HMG to the PC The successful connection will be symbolized by a green dot on the right hand edge of the window Pressing Disconnect in the Device box allows you to interrupt the existing connection between the HMG and the PC At the end you also have the option of selecting an automatic connection setup Placing a checkmark in the box for Set up connection next time automatical ly causes the HMGWIN software to set up a connection automatically with the HMG that is linked via USB during startup To ensure that this happens no changes should be made to the interface parameter settings after the currently existing connection is disconnected Click on OK to complete the connec
28. llow the specifications contained in this description Non observance of the instructions operation in applications other than those outlined below or incorrect handling of the product can be severely detrimental to the safety of personnel and systems machines and will invali date warranty and liability claims In the event of faults or if anything is unclear please contact your nearest HYDAC repre sentative Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 6 2 2 Proper use The PC software HMGWIN can be used in conjunction with the following HYDAC devices e Portable Data Recorder HMG 3010 e Portable Data Recorder HMG 3000 e Portable Data Recorder HMG 510 The software has been developed for processing and evaluating measured data which has been recorded using the above mentioned HYDAC devices We cannot accept any liability or provide warranty outside this field of application 3 Installation 3 1 Hardware and Software Requirements Equipment PC Pentium 400 MHz 256 MB RAM Windows XP 2000 CD ROM drive 3 MB free hard disk space RS232 interface RS 232 connector cable USB 1 1 Graphics resolution 640 x 480 256 colours recommended 1024x768 65536 colours 3 2 USB Driver Installation If the HMG 3010 is being connected with the PC for the first time first please install the HYDAC USB driver CP210x VCP Win XX exe The driver is included on the CD ROM contained in the scop
29. lly appears which serves as a place holder Anchor to measured value is activated by a checkmark in the white checkbox gt Entering placeholders using T for the actual time and 96V for the actual measured value is not possible unless Anchor to measured value is acti vated gt If you leave the placeholders T V and click on OK you automatically get a measured value for a specific time 2 quick and easy method for enter ing measured values in the graph Additional text can be entered or the placeholders can be deleted Fonts Here you can change the font size and colour and put the text in Bold Italic or Underline by clicking the respective checkbox gt A blue highlighted box with Set style as default appears To use these set tings as the default font settings left click on this box A window pops up containing the message The current style has been set as default Con firm with OK The message window closes Anchor The checkbox in front of Anchor to measured value is initially activated i e checked To enter text without anchoring it to a measured value deacti vate this function by clicking on the checkbox If the checkbox is activated you can select the sensor measurement channel to which the remark is to be anchored checkmark in the checkbox of the re spective sensor gt You can also indicate the time at which the remark is to be anchored to the measurement curve Yo
30. m Tab m List separator m Other Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 23 Select the column width for User defined ASCII ANSI format only m Without fixed width m Automatic optimum width m Fixed column width Export folder m Click on button next to input box m A window opens enabling you to browse for the folder File name m Keep name of recording m Ask for new name File extension for User defined ASCII ANSI format only m You can manually enter the file extension here Click on Ok to export the file Click on Cancel to cancel the action 4 6 7 Export Folder The Export Directory function enables you to save measured data in a format that can be exported to and read by a spreadsheet program e g Excel for example To export a directory please click the dialogue box File and select Export directory from the drop down menu Now the Export data window opens as in section 4 6 6 Select the time range to be exported Whole time range m Displayed time range Select the channels to be exported m All channels m Displayed channels Decide how unit of measurement should be displayed m Without unit or m Separate row Select the data format in which the recording is to be saved m Text separated by tabs m CSV separated by commas m Formatted text separated by spaces
31. me in the menu Manage settings To save the settings on the PC click Save in a file Retreiving already saved settings Load from HMG 3010 Please click on Load from HMG In the right box now the all settings saved in HMG 3010 appear Klicken Sie auf die gew nschte Einstellung Click on Open to apply the settings or Back to discard these changes You will automatically get back to the settings menu Load from PC 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 27 Please click on Load from file A window opens to open a file The settings now open but will NOT be stored in HMG 3010 4 7 2 4 Manage Settings e tis possible to manage the settings from your PC e Click on the Units dialogue box and select HMG3000 Manager from the drop down menu e Anew window for HMG 3000 Manager opens e Click on Manage settings on the left side of the window e You have an overview of your saved settings in the HMG as well as from the PC set tings Copy from settings In the left box now the all settings saved in HMG 3010 appear Select one or more settings from the list Select the copy requirements in the lowest box in the drop down menu Define the folder in which the settings will be saved by clicking on the right hand side of the window Now click the little arrow in the centre of both boxes the settings are saved e Delete from settings Click
32. n menu In the upper section you can select whether the recording is to be stored in black amp white Monochrome and whether the PDF file is to be opened directly after being created Show PDF document In the central section you can decide which portions of the recording are to be con tained in the printout by clicking on the checkbox before the particular portion In the lower section you can choose whether you want to print the recording in black amp white only Monochrome Click on Print at the bottom of the window Click on Cancel to cancel the action 4 6 9 Close To close the measurement curve you are currently editing click on the File dialogue box and select Close in the dropdown menu or click on Close at the bottom left of the window 4 6 10 Close all To close all open measurement curves click on the File dialogue box and select Close all in the dropdown menu or click on Close all at the bottom left of the window If you have not saved your recordings you are prompted to do so Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 25 4 7 Dialogue box Units 4 7 1 Connect e To establish a connection with a HMG device connected to the PC click on the Units dialogue box and select Connection from the drop down menu see Sec tion 3 5 e To change the connection settings you must first cut the existing connection Click on Disconnect and
33. n the dropdown menu You also have the option of clicking di rectly on Open at the bottom left of the screen Select the required recording in the relevant folder file extension herf To open recordings made with a previous version of the device e g HMG 2020 se lect Legacy formats as the file type in the dropdown menu file extension hmg cur pro Click on the File dialogue box In the dropdown menu above the Quit menu item you will find a list of the most recently opened recordings max 8 4 6 2 Import To import a text file exported from HMGWIN3000 click on the File dialogue box and select Import from the drop down menu Select the required file in the appropriate folder for this purpose Click on Open to import the file Click on Cancel to cancel the action Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 22 4 6 3 Save e To save a recording click on the File dialogue box and select Save in the dropdown menu or click on Save at the bottom left of the window e fthe recording has not yet been saved the Save recording as window opens 4 6 4 Save As e To save a file which hasn t been saved or to save an existing file under another name click on the File dialogue box and select Save as in the dropdown menu or click on Save as at the bottom left of the window e The Save as window opens 4 6 5 Save all
34. older When saving or opening recordings or settings the folder selected here is auto matically accessed Clicking on OK applies the settings and returns you to the main HMGWIN window Pressing Cancel takes you back without applying any changes 4 8 2 Reset options e Using the Reset options function you can reset all manually set options to the factory default settings 4 9 Dialogue box Help e Click on the Help dialogue box Select the Info function to find out the present soft ware version and to obtain the link to the HYDAC website Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 30 HYDAC ELECTRONIC GMBH Hauptstr 27 D 66128 Saarbr cken Germany Web www hydac com Email electronic hydac com Tel 49 0 6897 509 01 Fax 49 0 6897 509 1726 HYDAC Service For enquiries regarding repairs please contact HYDAC Service HYDAC SERVICE GMBH Hauptstr 27 D 66128 Saarbr cken Germany Tel 49 0 6897 509 1936 Fax 49 0 6897 509 1933 NOTE The information and particulars provided in this manual apply to the operating conditions and applications described herein For applications and operating conditions not described please contact the relevant technical department If you have any questions suggestions or encounter any problems of a technical nature please contact your Hydac representative Subject to technical modifications Trademarks Where trad
35. s opens Resolution settings Click on the upper arrow button A dropdown menu opens in which you can choose between the various resolution settings Without resolution The coarser the resolution the rounder the scaling in the fine resolution y axis meaning the measured values along the Y axis can medium resolution be more easily read at first glance large resolution 1 2 5 resolution This resolution corresponds to the difference between the largest and smallest value of the current display range Scaling is in incre ments of 0 1 0 2 0 5 1 2 5 10 20 50 If a value is exceeded the next larger value is used as the scaled range Example if the difference between the smallest and largest value is 49 bar scaling is from the smallest value to the argest value 50 if the difference were 51 bar scaling would be from the smallest value to the largest value 100 Scaling type of channels gt Scale all channels separately when default scaling is applied each channel is rendered optimally in a separate window with its maximum and minimum value Scale channels with the same unit jointly when default scaling is applied the smallest and largest measured value overall is used for scaling between these two values The same scaling is applied to all channels with the same unit Click on OK to apply the modified scale settings or Cancel to discard your chang es 4 4 11 Keyboard navigation
36. t measuring units of pressure temperature and fluid vol ume please click on Default Measuring Units In the right box now the default measuring units appear Select the relevant measuring unit for pressure temperature and fluid volume in the corresponding dropdown menu When you have completed all the settings for the measuring units click on OK to apply the changes Clicking Cancel takes you back without applying any changes To change the display settings click on Display settings Select the desired display settings as in HMG 3010 and define whether the minimum maximum values should be displayed or not When all the display settings have been carried out please click on OK to apply the changes or on Cancel to get back to the settings menu without applying any of the changes To change the CAN settings click on CAN settings You can only define up to 32 measuring values from pre defined CAN mes sages in case a CAN bus is connected the settings can be taken from the HMG 3010 manual When all the display settings have been carried out please click on OK to apply the changes or on Cancel to get back to the settings menu without applying any of the changes Saving the settings There are two options of saving the changed settings either in HMG 3010 or on your PC To save the settings in a file to be stored in HMG 3010 select Save in HMG Now you can enter a name In HMG 3010 you will now find this na
37. t the line type by clicking on the arrow button Options Solid line Dotted line and Dash dotted line Last section you can enter a remark for the measurement series Click on OK to save your changes or Cancel to discard them If you only want to change the settings of one channel e g hide it click on this chan nel in the upper right next to the graph view The Settings window opens in which the tab of this measurement channel is preselected 4 4 15 Backwards To undo changes in the graph view click on the Graph dialogue box and select View in the dropdown menu and Back in the submenu or select Back at the bottom of the screen In this way the changes can be undone step by step You can do this as many times as there are changes 4 4 16 Forwards To redo changes which have been undone in the graph view click on the Graph di alogue box and select View in the dropdown menu and Forwards in the sub menu or select Forwards at the bottom of the screen In this way the changes can be restored step by step You can do this as many times as there are changes to redo Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 18 4 4 17 Save view To save a zoomed view for example click on the Graph dialogue box and select View in the dropdown menu and Save view in the sub menu or select Save view at the bottom of the screen A window opens where
38. te wizard opens Click Continue to proceed Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 29 e Now select the folder in which the update file is saved The most recent firmware ver sion can be found on the CD contained in the scope of delivery of the HMG 3010 The firmware is located in the Installation directory e An update file always has the heupd extension Select the relevant update file and click on Open e Follow the instructions of the Setup Wizard e How to activate the update for HMG 3010 please see the HMG 3010 manual 4 8 Dialogue box Extras 4 8 1 Options e Click on the Extras dialogue box and select Options in the dropdown menu e After selecting the function the Options window opens with the following setting op tions m Inthe Language box you can select either German English or French as the HMGWIN system language m Working folder The configuration file of HMGWIN 3000 is stored in the Options folder If you do not specify a folder this file HMGWINConfig xml is stored in the folder in which the HMGWIN 3000 exe application is also located If more than one user is working with HMGWIN each user can create their own Options folder When the user selects this folder after launching HMGWIN HMGWIN uses the configuration customized by this user This enables different users to work with their own customized configuration settings made in HMGWIN m Working f
39. tion setup Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 8 3 5 1 Communication error If no connection should be possible to your HMG 3010 this could have the following rea sons e Error cause at HMG 3010 e Check if HMG 3010 is switched on and if USB has been selected when con necting the USB under Settings Change basic settings PC connection e Error cause PC e Check in the device manager if all drivers have been installed properly If no driver or just one driver has been installed the Silicon Labs CP210x USB to UART Bridge will be marked by a question mark e Inthis case please repeat installing the drivers Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 9 4 Using HMGWIN Note For all options selections can only be made using the mouse 4 1 View current measured values of HMG 3010 in HMGWIN 3000 e To view current measured values of the HMG Click on the Units dialogue box and select HMG3000 Manager from the drop down menu A new window for HMG 3000 Manager opens Click on Display measured values on the left side of the window The measured values of all active channels of HMG 3010 appear on the right side of the window By clicking full screen view the measured values are displayed in a larger size in an extra window By clicking Min Max the minimum and maximum values of each sensor are s
40. u can either enter the time in ms or change it by click ing the arrow keys next to the time box with your mouse One click on one of the arrows Av corresponds to a change by the preset measurement rate e When you are finished entering your settings confirm by clicking on OK e f you click on Cancel your remarks will be discarded e After clicking on OK the Remark window closes and the remark box can now be seen f anchoring has been activated the remark box is linked to the selected curve by a line The circle at the end of the line shows which measured value the remark re fers to f anchoring has been deactivated only the remark is visible e The remark can be edited and shifted later providing the remark function has been en abled Hierzu muss die Anmerkungsfunktion eingeschaltet sein The position at which the remark is anchored to the measurement curve can be shifted by moving the mouse pointer over the anchor position If you hold the left mouse button down you can drag the anchor to the required position If you have entered the placeholder it is adjusted accordingly when you release the mouse button The anchor point is always a measured value since the remark is an chored to the measurement curve The remark box itself can be shifted by moving the mouse pointer over the remark box it is now blue highlighted Click and hold down the left mouse button and move the remark box to the required position To edit
41. ure difference in the submenu or select Measure difference at the bottom of the screen Measure difference is now highlighted at the bottom of the screen When you move the mouse over the graph the mouse pointer turns into a caliper Using the caliper select one of the two points between which you would like to measure the distance and press the left mouse button A crosshair in bold each of the hairs consisting of two thin parallel lines appears along with a colour highlighted numerical value on each of the axes showing the dis tance If you move the mouse over one of the axes a double arrow T appears If you hold the left mouse button down you can pull the thick line apart and drag one of the lines to the level of the second point The color highlighted numerical value changes indicating the distance You can repeat this with all four lines as often as you like After selecting the first point you can also hold down the left mouse button and im mediately select the second point Here too a new starting point can be repeatedly selected by clicking on another point in the graph 4 4 3 Tracking Click on the Graph dialogue box and select Evaluation in the dropdown menu and Track in the submenu or select Track at the bottom of the screen Tracker is now highlighted at the bottom of the screen When you move the mouse over the graph the mouse pointer turns into a vertical bro ken line Click left mouse button on
42. x at the top The formula can be comprised of numbers measured values arithmetical opera tors and functions For measured values use S1 Sn in the formula Example 5 S1 S2 2 For detailed information on the formula contents and symbols click on Help located in the line below on the right Click on Help again to close the window The unit of the channel being calculated can be entered manually in the Unit input box Select the number of decimal places for the measured values displayed 0 8 decimal places After entering a formula to be calculated click on Calculate in the line at the bottom of the window The computed curve is now inserted This process can be repeated as often as desired Click on OK to close the window Clicking on Cancel also closes the window but the calculated channels are removed again On the right of the screen you will now find the calculated channels The settings can be changed here as for any other channel Calculated channels are always marked with an asterisk Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 21 4 5 5 Add a filtered channel To remove noise from a measurement for example click on the Edit dialogue box and select Adding calculated channels in the dropdown menu A window for filtering the channel opens Clicking on the button next to the channel input box causes a dropdown menu to appear in which all ch
43. y a HSI sensor i e HYDACLab please select HSI Log as file type in the dropdown menu Click on the File dialogue box In the dropdown menu above the Quit menu item you will find a list of the most recently opened recordings max 8 4 2 3 Retrieving an open file All open files are listed on the left hand side of the window and can be retrieved for further work using the program by clicking on the file name Status 2010 05 22 HYDAC ELECTRONIC GMBH Part No 669847 PC Software HMGWIN 3000 Page 11 4 3 Dialogue box View There are four view options for a measurement curve Graph Table Recorded data De scription All four views can be selected either in the dropdown menu of the View dia logue box or at the lefthand lower edge of the screen e Graph displays the measurement curve as a function for editing options see Work ing on a Measurement Curve and Editing a Measurement Curve The time is shown in the X axis the measured values of the curves are shown in the Y axis the curves being shown in the relevant colour for hiding or showing see Settings e Table table showing the measured values of the individual sensors recorded at a par ticular point in time e Recorded data m General type of measurement curve number of sensors number of data rec ords start and end date of the measurement etc m Channels with their measurement ranges e Description Designation and remarks entered
44. you can enter a name and a description for the saved view Click on OK to save the view or Cancel to discard it and return to the graph 4 4 18 List saved views List views is used to jump back and forth between various saved views To view a saved view or select or rename it click on the Graph dialogue box and se lect View in the dropdown menu and List views in the sub menu or select List views at the bottom of the screen A window with the saved views opens This window is divided in two The upper part contains a listing of all views with their names the bottom part a description of the view currently selected You can select any view by clicking on it with your mouse When selecting a view the view is shown in the background and its description appears in the lower section Select OK Delete and Rename from the bar at the bottom of this window OK closes the window Delete deletes the selected view Rename to rename the selected view A window for renaming the view is opened You can enter a new name and con firm by clicking OK the new name is applied or discard the action by clicking Cancel the old name will be kept 4 4 19 Create picture Click on the Graph dialogue box and select Other in the dropdown menu and Create picture in the submenu or select Create picture at the bottom of the screen A new window opens in which the current graph view is shown as a picture In th