1. coasting to a stop is recommended for frequent starts and stops Frequent starting and stopping can produce high torque This may cause damage to motors Do not disconnect any of the motor leads from the drive unless power is removed or the drive is disabled Opening any one lead while the drive is running may destroy the drive Under no circumstances should power and logic level wires be bundled together Be sure potentiometer tabs do no make contact with the potentiometer enclosure Grounding the input will cause damage to the drive Caution should be taken when operating fan cooled motors at low speeds because their fans may may not move sufficient air to properly cool the motor Minarik Drives recommends inverter duty motors when the speed range is beyond 10 1 Drive is designed to work with permanent split capacitor shaded pole and standard three phase induction motors In general the drive can work with capacitor start motors but it is conditional on the current pull when the capacitor is in effect and how long the application calls for a speed that the capacitor will stay in the auxiliary winding MTT ML ALL DIMENSIONS IN INCHES MILLIMETERS Connections POWER Line Input Connect the AC line power leads to terminals L1 and L2 115 or to a single throw single pole master power switch recommended The switch should be rated at a minimum of 120
2. Mvo ay isooa wv e 8 E N NO ENABLE DISABLE SWITCH open to disable DIRECTION SWITCH SELECT SWITCHES Select Switch SW501 Switch 1 ON Manual Restart Enable must be opened to clear fault and restart drive Drive will fault for under voltage or if the enable is closed when power is applied OFF Auto Restart Drive will restart when fault condition is removed Drive will fault for under voltage The drive will not fault if the enable is closed when power is applied Switch 2 ON DC Injection Braking The drive will use DC injection braking to quickly decelerate the motor OFF Coast to Stop The fastest the motor will decelerate is a natural coast to a stop Switch 3 ON 50 Hz motor setting OFF 60 Hz motor setting G Switch 4 ON 1 6 kHz Carrier Frequency OFF 16 kHz Carrier Frequency L115 vac IN Dip Switch SW501 STARTUP Verify that no foreign conductive material is present on the printed circuit board Ensure that all dip switches are properly set 1 Turn the speed adjust potentiometer full counterclockwise CCW 2 Apply AC line voltage 3 Enable the drive 4 Slowly advance the speed adjust potentiometer clockwise CW The motor slowly accelerates as the potentiometer is turned CW Continue until the desired speed is reached
3. 5 Remove AC line voltage from the drive to coast the motor to a stop Power IL2 Green LED lights whenever AC line voltage is applied to the drive Solid Power is applied and the output is disabled Flashing Power is applied and the output is enabled Status IL1 Red LED lights whenever a fault condition occurs Solid Current Limit The motor is asking for more current than drive is set to allow out 2 Undervoltage Internal DC BUS voltage dropped too low Overvoltage Internal DC BUS voltage rose too high Short Circuit Short circuit between any two phases on output Overtemperature Warning Drive s temperature is approaching critical temperature Overtemperature Shut Down Drive s temperature has reached critical temperature Manual Start Trip Power was applied while the enable was closed only applicable if switch 1 on SW501 is set to ON _ 115 VAC IN MAX aca B le ar EB soosr Copyright 2011 by Minarik Drives All right reserved No part of this document may be reproduced or retransmitted in any form without written permission from Minarik Drives The information and technical data in this manual are subject to change without notice Minarik Drives makes no warranty of any kind with respect to this material including but not limited to the implied warranties of its merchantability and fitness for a given purp
4. Specifications Motor Voltage VAC Line Voltage VAC Continuous Motor Current Motor Horsepower 115 VAC 10 50 60 Hz single phase 2x motor current AC Line Voltage AC Line Current AC Motor Voltage Overload Capability Standard Carrier Frequenc Output Frequency Range Adjustable Maximum Output Frequency Range Adjustable Minimum Output Frequency Range Adjustable DC Injection Voltage Acceleration Time Range Deceleration Time Range Analog Input Voltage Range Signal must be isolated Input Impedance S1 to 2 Vibration 20 50 H2 gt 50 Hz 0 1G maximum Ambient Temperature Rang 20 C 40 C WlBlits RINES AE IE E IE A AEREE TE dean AT 1 4 Ibs 30 120 Hz 0 50 of maximum 0 17 VDC 1 12 seconds 1 12 seconds Installation Drive components are sensitive to electrostatic discharge Avoid direct contact with the circuit board Hold the drive by the chassis only Protect the drive from dirt moisture and accidental contact Provide sufficient room for access to the terminal block and calibration trim pots Mount the drive away from heat sources Operate the drive within the specified ambient operating temperature range Prevent loose connections by avoiding excessive vibration of the drive Mount the drive with its board in either a horizontal or vertical plane Four 0 20 5 mm wide slots in the chassis accept 8 pan head screws The chassis should be earth grounded Use a sta
5. VAC and 150 of line current Motor If using a three phase motor connect the AC motor leads to terminals U V and W If the motor does not spin in the desired direction power down the drive and swap any two of these connections If using a single phase motor connect the AC motor leads to terminals U and V Refer to the Operations section for possible wiring setups LOGIC Speed Potentiometer Use a 5K 20K ohm 1 4 W potentiometer for speed control Connect the counter clockwise end of the potentiometer to S1 the wiper to 2 and the clockwise end to 3 If the potentiometer works inveresly of desired functionality i e to increase motor speed you must turn the potentiometer counterclockwise power off the drive and swap the S1 and 3 connections Direction Switch If a direction switch is desired wire a switch to terminals E1 and DIR When the connection is open the motor will run in the forward direction When the connection is closed the motor will run in reverse If no direction switch is desired leave this connection open Enable Open the terminals E1 and E2 to coast the motor to minimum speed Close terminals E1 and E2 to accelerate the motor to set speed If no enable switch is desired jumper terminals E1 and E2 Do not use the enable for emergency stopping NEUTRAL AC LINE VOLTAGE 115 VAC STOP FUSE SWITCH HOT SU noo ans Z e z KE Dad
6. isconnected from the drive connect a RMS ammeter in series with one of the motor leads Turn the TQ LIM trim pot to full CW Apply power and adjust the motor speed to full rated speed Load the motor so that it draws the RMS current previously determined Slowly turn the TQ LIM trim pot CCW until the red LED starts flickering Then turn the trim pot slightly more so that it just starts to reduce the motor amps on the RMS ammeter 250 0509 rev 1
7. justed If the motor stalls or runs erratically at very low speeds below 10 Hz the boost trim pot may need adjustment To calibrate the BOOST 1 Run the motor at the lowest continuous speed frequency required 2 Increase the BOOST trim pot until the motor runs smoothly Continuous operation beyond the motor s current rating may damage the motor Acceleration ACCEL The ACCEL setting determines the time the motor takes to ramp to a higher speed ACCEL is factory set for the shortest acceleration time full CCW To calibrate the ACCEL 1 Set the speed adjust potentiometer for minimum speed 2 Set the speed adjust potentiometer for maximum speed Measure the time is takes the motor to go from minimum speed to maximum speed 3 If the time measured in step 2 is not the desired acceleration time turn the ACCEL trim pot CW for a longer acceleration time or CCW for a shorter acceleration time Repeat steps 1 through 3 until the acceleration time is correct Deceleration DC Injection Braking DECEL DC BR In Coast to Stop Mode Dip Switch 2 OFF the Decel setting determines the time the motor takes to ramp to a lower speed Decel is factory set for the shortest deceleration time full CCW To calibrate the DECEL 1 Make sure Dip Switch 2 is OFF See STARTUP section for dip switch location 2 Set the speed adjust potentiometer for maximum speed 3 Set the speed adjust potentiometer for minimum speed Measure the time is takes the moto
8. nd safety codes including the provisions of the Occupational Safety and Health Act OSHA when installed equipment Circuit potentials are at 115 above earth ground Avoid direct contact with the printed circuit board or with circuit elements to prevent the risk of serious injury or fatality Use a non metallic screwdriver for adjusting the calibration trim pots Use approved personal protection equipment and insulated tools if working on this drive with power applied Reduce the chance of an electrical fire shock or explosion by proper grounding over current protection thermal protection and enclosure Follow sound maintenance procedures Minarik Drives strongly recommends the installation of a master power switch in the line voltage input The switch contacts should be rated for 250 VAC and 200 of motor nameplate current Removing AC line power is the only acceptable method for emergency stopping Do not use DC injection braking decelerating to minimum speed or coasting to a stop for emergency stopping They may not stop a drive that is malfunctioning Removing AC line power is the only acceptable method for emergency stopping Line starting and stopping applying and removing AC line voltage is recommended for infrequent starting and stopping of a drive only DC injection braking decelerating to minimum speed or 4 41 112 3 71 94 2 L070 17 80 nsvac IN z gt i oo
9. ose Minarik Drives assumes no responsibility for any errors that may appear in this document and makes no commitment to update or to keep current the information in this document Operation MOTOR CONNECTIONS Single Phase Operation Non reversing For single phase operation connect the motor as show in the figure below Ensure that the prewired capacitor and its associated motor coil are connected to terminals U and V as shown This connection may be internal if using a 2 wire motor If the motor has three leads you must make this connection yourself AUXILIARY WINDING PREWIRED This connection may be RUN CAPACITOR internal to the motor 2 wire If not you must make this connection U V MAIN WINDING Single Phase Operation Reversing Remove the capacitor and connect the motor as show in the figure below While allowing for solid state reversing this wiring scheme may result in sub optimal motor operation Depending on the motor construction and application requirements the motor may need to be derated MAIN WINDING AUXILIARY WINDING WITHOUT CAPACITOR U V W Three Phase Operation For three phase operation connect the motor as show in the figure below Connect to terminals U V and W as shown MOTOR WINDING MOTOR WINDING MOTOR WINDING Calibration Minimum Speed MIN The MIN setting determines the motor speed when the speed adjust potentiometer is set for minimum speed It is factory set for
10. r to go from maximum speed to minimum speed 4 If the time measured in step 2 is not the desired deceleration time turn the DECEL trim pot CW for a longer deceleration time or CCW for a shorter deceleration time Repeat steps 1 through 3 until the deceleration time is correct In DC Injection Braking Mode Dip Switch 2 ON the DC Injection Braking setting determines the amount of current injected into the motor to quickly brake the motor To calibrate the DC BR 1 Make sure Dip Switch 2 is ON See STARTUP section for dip switch location 2 Set the DC BR trim pot full CCW 3 Enable the drive 4 Turn up the speed adjust potentiomter to full speed 5 Disable the drive 6 If the motor decelerates to zero speed too slowly increase the DC BR trim pot and repeat steps 2 through 5 until the motor stops within the desired time Torque TQ LIM The TQ LIM setting determines the maximum torque for accelerating and driving the motor If torque limit adjustment is desireable but not critical use the chart below for approximate TQ LIM trim pot settings Note that positions are relative to trim pot not mounting position ie 8 00 is full CCW on trim pot 100 11 30 10 30 9 30 8 30 150 2 00 11 30 10 30 9 00 200 4 00 2 00 11 30 9 30 1 2 HP 1 3 HP 1 4 HP 1 8 HP If torque limit adjustment is critical determine the motor s RMS current that correlates to desired torque limit and then With power d
11. r washer beneath the head of at least one of the mounting screws to penetrate the anodized chassis surface and to reach bare metal Wiring Use 18 24 AWG wire for logic wiring DIR E1 E2 S1 S2 3 Use 14 16 AWG wire for AC line L1 L2 and motor U V W wiring Shielding Guidelines As a general rule Minarik Drives recommends shielding of all conductors If it is not practical to shield power conductors Minarik Drives recommends shielding all logic level leads If shielding of logic level leads is not practical the user should twist all logic leads with themselves to minimize induced noise Refer to the user s manual for details on earth grounding shielded wires and filtering Fusing Minarik Drives drives require an external line fuse for protection Use fast acting fuses rated for 250 VAC or higher and 150 of the maximum line current Fuse the HOT leg of the AC line UPVFD04 115AC Open Chassis Microprocessor based Variable Frequency AC Drive Safety Warnings READ ALL SAFETY WARNINGS BEFORE INSTALLING THIS EQUIPMENT DO NOT INSTALL REMOVE OR REWIRE THIS EQUIPMENT WITH POWER APPLIED Have a 14300 De La Tour Drive Phone 800 646 2745 Fax 800 394 6334 www minarikdrives com South Beloit IL 61080 Full manuals available online Dimensions 6 90 17 5 qualified electrical technician install adjust and service this equipment Follow the National Electrical Code and all other applicable electrical a
12. zero speed To calibrate the MIN 1 Set the MIN trim pot full CCW 2 Set the speed adjust potentiometer for minimum speed full CCW 3 Adjust MIN trim pot until the desired minimum speed is reached Maximum Speed MAX SPD The MAX setting determines the motor speed when the speed adjust potentiometer is set for maximum speed To calibrate the MAX SPD 1 Set the MAX SPD trim pot full CCW 2 Set the speed adjust potentiometer for maximum speed full CCW 3 Adjust MAX SPD trim pot until the desired maximum speed is reached Slip Compensation SLIP COMP The SLIP COMP setting determines the degree to which motor speed is held constant as the motor load changes It is factory set for optimum motor regulation To calibrate the SLIP COMP Set the SLIP COMP trim pot full CCW Increase the speed adjust potentiometer until the motor runs at midspeed without load A handheld tachometer may be used to measure motor speed Load the motor to its full load current rating The motor should slow down While keeping the load on the motor rotate the SLIP COMP trim pot until the motor runs at the speed measured in step 2 If the motor oscillates overcompensation the SLIP COMP trim pot may be set too high CW Turn the SLIP COMP trim pot CCW to stabilize the motor Unload the motor Boost BOOST The BOOST setting increases the motor torque at low speeds The minimum setting is sufficient for most applications and does not need to be ad
Download Pdf Manuals
Related Search
Related Contents
V-520 Mini GPS Tracker (GPS+SMS+GPRS) - Sunsky Infos Communales Album Photos ASSOCIATIONS Dell 100-Mbps Network Card User Manual User Manual SUNNY BOY 5000-US/6000-US/7000-US/8000-US Extincteurs Portatifs au Dioxyde de Carbone Manuel d`Entretien Monitor Audio BX1 loudspeaker Copyright © All rights reserved.