Home

CSE-M53N User Manual

image

Contents

1. 30 31 32 33 34 35 36 37 01234567 Data Length H jf Appiy Apply Received Data D Byte s COM Port Baudrete Parity Data Bits Stop Bit E Control Open COM1 19200 NONE COM1 Opened 8 Figure 2 6 COM Port open message Check the message if the COM port has been opened e Sollae Systems Co Ltd 22 http www ezTCP com CSE M53N User Manual Ver 1 7 Data transmission test 30 31 32 33 34 35 36 37 01234567 30 31 32 33 34 35 36 37 101234567 Data Length Received Data 0 Byte s Co fe seve JC ce 7 Peer Port Local Port Peer Address TCP Client v 10 1 0 1 1470 Keep Alive IPv4 IPv 30 31 32 33 34 35 36 37 01234567 O Byte s 30 31 32 33 34 35 36 37 01234567 Data Length Received Data ee Cx ax Stop Bit Flow Control Open Data Bits COM Port Baudrate Parity COM1 e 19200 COM1 Opened Figure 2 7 successful data transmission Click the Send data on the LAN part Check the data have been shown from the step eo e LAN RS232 PC CSE M53N Figure 2 8 LAN gt RS232 Press the Send data on the RS232 part Check the data have been received from the step eo e LAN RS232 CSE M53N PC Figure 2 9 RS232 gt LAN e Sollae Systems Co Ltd 23 http www ezTCP com CSE M53N User Manual Ver 1 7 3 Configuration 3 1 Configuration with ezManager 00 mp 11 00 o Search Results 1 KI CENIE WEEN
2. CSE M53N User Manual Ver 1 7 2 2 1 Setting Network Aera This step is for setting both CSE M53N and users PC to be located the same network If only they are the TCP connection between them can be established 6 Setting of the PC Add or change the IP address of the network adapter on your PC like following Get into the menu of Windows Control Panel gt gt Network Connections gt gt Properties of the Network Adapter with right click of your mouse Then you can show the properties of Internet Protocol TCP IP In there press the Advanced button for adding an IP Address like the below figure Internet Protocol Version 4 TCP IPv4 Properties Subnet mask 255 0 0 0 Automatic metric Interface metric Figure 2 2 adding changing the IP address of users PC e Sollae Systems Co Ltd 19 http www ezTCP com CSE M53N User Manual Ver 1 7 6 Setting of CSE M53N CSE M53N uses ezManager as it s a configuration program ezManager is for MS Windows and this is comfortable to use because it doesn t need installation First search your CSE M53N via network All the values of parameters are set the default values in the factory To apply it to your system proper values should be set via ezManager Major parameters default values are listed on below table To implement this simple test keep these values without any changes Table 2 1 default values of Major parameters Refer
3. Figure 7 2 Create the certification 3 Choice the Write self signed certificate prenas O Write self signed certificate Write signed certificate from certification authorities Read the certificate from ezTCP Lo eng _ Figure 7 3 Create the RSA Key e Sollae Systems Co Ltd 54 http www ezTCP com CSE M53N User Manual Ver 1 7 Input the key length and information in Self signed certificate Self Signed Certificate Length of RSA Key Country Name 2 letter code AU INCHEON State of Province NAme full name Some State Locality Name eg city EH Organization Name eg company Internet Widgits Pty Ltd SOLLAE SYSTEMS Organizational Unit Name eg section Ses Common Name eg YOUR name Email Address Figure 7 4 Input the information Check a success message ezTCP Manager v3 2A 20 A Writing the environment variables has been successfully completed Figure 7 5 Check of success message 7 1 3 Restriction 6 If user set the SSL with the CSE M53N the other device have to set the SSL 6 Maximum baud rate of serial port is the 115 200bps 6 Cannot use SSL feature in Ipv6 e Sollae Systems Co Ltd 55 http www ezTCP com CSE M53N User Manual Ver 1 7 7 2 Access Restriction ezTCP Firewall On the Option tab of ezManager you can set access restriction function with MAC and IP address Allowed MAC
4. J lt TCPAP_ gt Remote Host CSE M53N BEN 3 Bytes Figure 5 5 time chart for a situation that Event Byte is set to 5 CSE M53N has receives data from its serial port until the amount of data is 5 bytes D Sends connection request segment right after receiving 5 bytes Processes of the TCP connection The connection has been established Es The 1234567 is transmitted to the remote host Table 5 8 states of each points As you can see in the figure 5 5 CSE M53N sends request segment right after the serial data had been 5 bytes Even though those are come before the connection is established the data 123 45 and 67 are transmitted to the remote host because of the Event Byte is set to 5 e Sollae Systems Co Ltd 36 http www ezTCP com CSE M53N User Manual Ver 1 7 6 An activated TCP Server option _ Serial ci Remote Host1 CSE M53N Remote Host2 Table 5 9 states of each points The TCP Server Client mode can be useful option by using Event Byte and Timeout Note that only one TCP connection can be established at the same time so users should consider setting Timeout properly e Sollae Systems Co Ltd 37 http www ezTCP com CSE M53N User Manual Ver 1 7 5 3 AT Command AT command is a mode which users control CSE M53N with AT command like controlling modem In this mode active and passive TCP connections are available And users are
5. 10 1 Technical Documents You can find the technical documents at our website 6 DataSheet IP Change Notification DDNS 6 Sending MAC Address function TCP Server Client mode Telnet COM Port Control Option 10 2 Smart phone Application 6 ezManager IOS 6 ezManager Android TCP IP Client Android amp Sollae Systems Co Ltd 65 http www ezTCP com CSE M53N User Manual Ver 1 7 1 Technical Support and Warranty 11 1 Technical Support If you have any question regarding operation of the product visit Customer Support FAQ corner and the message board on Sollae Systems web site or send us an email at the following address 6 E mail support eztcp com Website Address for Customer Support http www eztcp com en support 11 2 Warranty 11 2 1 Refund Upon the customer s request to refund the product within two weeks after purchase Sollae Systems will refund the product 11 2 2 Free Repair Services For product failures occurring within two years after purchase Sollae Systems provides free repair services or exchange the product However if the product failure is due to user s fault repair service fees will be charged or the product will be replaced at user s expense 11 2 3 Charged Repair Services For product failures occurring after the warranty period two years or resulting from user s fault repair service fees will be charged and the product will be replaced at user s expense Souad S
6. 5 Obtain an IP Automatically DHCP Obtain an IP Automatically PPPOE PPPoE ID PPPoE Password Obtain DNS Server Address Automatically Use static IP address Obtain an IP Automatically See V Advanced Menu nara Message ap Figure 3 1 initial appearance of ezManager 3 1 1 Configuration via LAN 6 Checklists Make sure the connection between your PC and CSE M53N If they are the same network MAC Address search button can be used If they aren t only IP Address search is allowed to use Procedures 1 Searching Use Search All or Read button on ezManager 4 Writing Store the setting with Write button Figure 3 2 procedures for configuration via LAN e Sollae Systems Co Ltd 24 http www ezTCP com CSE M53N User Manual Ver 1 7 3 1 2 Configuration via Serial 6 Checklists Make sure the connection between your PC and CSE M53N using RS232 cross cable To use this CSE M53N has to be operating in the Serial Configuration mode By connecting ISP pin with GND LOW less than 1 second you can enter the mode After this read the setting via Serial tab on ezManager Procedures 1 Mode Switching Change the mode to Serial Configuration 2 Reading Read environmental parameters with Read button 3 Setting Set the values of the parameters properly 4 Writing Store the setting with Write button Figure 3 3 procedures
7. Click the Change F W HTML button Denn m Figure 6 1 running TFTP client Check the Advanced Menu check box Click the Change F W HTML button to run TFTP client Select the Change Firmware radio button Input the IP address of CSE M53N to the Local IP Address text box Press the Open Firmware HTML button and choose the firmware file OF WHO amp Sollae Systems Co Ltd 45 http www ezTCP com CSE M53N User Manual Ver 1 7 6 Checking firmware file and Sending Local IP Address 9 as Change 115 200 bps 230 400 bps 460 800 bps CRC A83B C Users Roy Desktop MS3NR10B 01 BIN Local IP Address Change Zi rna Change HTML 1 en Sonn le cire 115 200 bps 230 400 bps 460 800 bps CRC A83B C Users Roy Desktop MS3NR10B 01 BIN ezTCP Manager v3 2A 2012 i Downloading firmware has been successfully completed 3 Le Figure 6 2 sending firmware file Check if the name and path of the firmware file are correct 2 Click the Send button 3 Confirm the completed message e Sollae Systems Co Ltd 46 http www ezTCP com CSE M53N User Manual Ver 1 7 6 2 Status Monitoring 6 2 1 Using TELNET Once the TELNET option is activated users can remotely log in to CSE M53N If a password is set users should input the password After then messages from CSE M53N appear like the below figure CSE M53N Management Console v1 0E Sollae Systems Ish g
8. Manual Ver 1 7 TCP Client setting parameters and active connection E Remote Host Figure 5 8 TCP Active connection Set parameters in the AT command mode S CSE M53N sends a TCP connection request with the ATD command Processes of TCP connection TCP connection has been established CSE M53N sends CONNECT message to the serial port Table 5 12 states of each points e Sollae Systems Co Ltd 40 http www ezTCP com CSE M53N User Manual Ver 1 7 6 Termination of online status entering the AT command mode Serial Figure 5 9 Termination of online status Keeps TCP connection CSE M53N enters the AT command mode with receiving Keeps AC command mode Processes of TCP disconnection TCP connection has been terminated CSE M53N terminates TCP connection with ATH command CSE M53N sends NO CARRIER with disconnection Table 5 13 states of each points CSE M53N changes the mode to AT command when receiving and sending OK message In this state the communication with remote host is not possible because CSE M53N processes only AT command Whenever you want to go back to online state TCP connection use ATO command Refer to the At Command ATC Mode document on our website for details e Sollae Systems Co Ltd 41 http www ezTCP com CSE M53N User Manual Ver 1 7 5 4 UDP UDP has no connection processes In this mode data is sent in bl
9. NO ele 18 22 OR 18 2 2 1 Setting Network 462 19e E R Trei e WSSU cece ctecas ce crsces ce rece ce sce E cores geen caren cseeei coreees ceteeoi cote el CCNA E 24 3d Coniguration With MAR eE EEEE E Ei 24 LL E ST E AN e ee 24 CO OO E EAA DE SEET SE 4 Operation e TE 27 4 1 What is the Operation MO vole e How to entering each MOde essen L 4 3 Comparison with each mode iii 28 v NOA e 28 d SAC OR EE E 29 e Sollae Systems Co Ltd 2 http www ezTCP com CSE M53N User Manual Ver 1 7 e et SET 4 6 1 Upgrading Ermare res 27 4 6 2 Revoking Serurity e resident 229 5 eu len nde Ne E 30 Set Ee 30 ee KOV e lee L 30 5 12 Eames SL Be Le cen scenes sre pene gee ap ce aera y cece pce geen gees seeeeee raat 34 ad So A E A E E EE E E 34 Sa ee oo e ALCON N sce ance E oc tees teens seceeecteceees este eee 38 5 3 1 EE 38 Ge ee 259 RUE A S 42 5 4 1 Key EE E 42 e eee 43 6 System leren 45 61 Upgrading NE ce coae seacoass secon seerat stccansestecoiesicateee 45 Eeer E CO EE TAS 45 EE e a De e E 47 E E ee ER EE 47 6 22 Using MANAQE ere een ni are ee eee ee nie tes 50 7 Additional 27T a 71 EE 54 F DE 54 7 1 1 What ts the SSL Secure Socekt Layer nn 54 Tda AOW AO SET CO DSL a ee eee ee E 54 E EE eege SE 7 2 Access Restriction ezTCD Firewall ege 56 OO 56 5 ee De NET Rtl d ni sieste etats en
10. allowed to configure some environmental parameters with extended commands 5 3 1 Key parameters The configuration should be implemented via the serial port of CSE M53N Table 5 10 some of extended commands for configuration 6 Related items with IP Address and Local Port Local port can be set as well as IP address related parameters like IP Address Subnet Mask and Gateway IP Address Peer Address Peer Port IP address and local port of a remote host are can be set 6 Type of assigning IP address Manual DHCP PPPoE Not only manual setting also automatic assigning protocol DHCP PPPoE are available Others Some of options including Timeout can be configured in this mode e Sollae Systems Co Ltd 38 http www ezTCP com CSE M53N User Manual Ver 1 7 5 3 2 Examples TCP Server setting parameters and passive connection Remote Host Figure 5 7 TCP passive connection Set parameters in the AT command mode CSE M53N listens TCP connection requests with the ATA command CSE M53N is listening TCP connection requests Processes of TCP connection TCP connection has been established CSE M53N sends CONNECT message to the serial port A remote host has sent SYN segment to CSE M53N Table 5 11 states of each points Most of the response messages from the serial port of CSE M53N are omitted on above figure e Sollae Systems Co Ltd 39 http www ezTCP com CSE M53N User
11. celui ci pourrait cr er une situation dangereuse pouvant entra ner des pertes financi res des d g ts mat riel des blessures corporelles ou la mort de personnes ou d animaux Si vous e Sollae Systems Co Ltd 69 http www ezTCP com CSE M53N User Manual Ver 1 7 utilisez le bo tier CSE M53N volontairement ou involontairement pour de telles applications non autoris es vous vous engagez soustraire Sollae Systems Co Ltd et ses distributeurs de toute responsabilit et de toute demande de d dommagement En cas de litige l enti re responsabilit de Sollae Systems Co Ltd et de ses distributeurs vis vis de votre recours durant la p riode de garantie se limitera exclusivement selon le choix de Sollae Systems Co Ltd et de ses distributeurs au remboursement de votre produit ou de sa r paration ou de son change Sollae Systems Co Ltd et ses distributeurs d mentent toutes autres garanties exprim es ou implicites Tous les bo tiers CSE M53N sont test s avant exp dition Toute utilisation en dehors des sp cifications et limites indiqu es dans cette documentation ainsi que les court circuit les chocs les utilisations non autoris es pourront affecter la fiabilit cr er des dysfonctionnements et ou la destruction du bo tier CSE M53N sans que la responsabilit de Sollae Systems Co Ltd et de ses distributeurs ne puissent tre mise en cause ni que le bo tier CSE M53N puisse tre chang au titre de la g
12. for configuration via Serial 6 Step 2 Reading oeo Figure 3 4 reading procedure via serial U Choose the Serial tab Select the COM port which the CSE M53N is connected with 3 Open the COM port with the Open button GO Load the setting with Read button e7 Refer to the ezManager manual on our website for details You can download ezManager application for a smartphone on our website e Sollae Systems Co Ltd 25 http www ezTCP com CSE M53N User Manual Ver 1 7 3 2 AT command In the AT command mode you can change some parameters through the serial port 6 Checklists Make sure the connection between your PC and CSE M53N using RS232 cross cable To use this CSE M53N has to be set to AT command mode as its communication mode This can be configured by ezManager Figure 3 5 setting the communication mode to the AT command Procedures eg Cole R TEL Set the communication mode to the AT commands 2 Opening Terminal Run a serial terminal program like HyperTerminal 4 Writing Store the setting with the AT PWP command Figure 3 6 procedures for configuration with AT command Division Available parameters Local IP Address DHCP PPPoE Subnet Mask Gateway IP Address DNS IP Address IP Address related items Local Port Peer Address IP Address or Host name Peer TCP connection related items POM ESC code sending option timeout Table 3 1 parameters wh
13. is a function that CSE M53N automatically sets its peer host with information of the last packet received from network The source address of the packet is set to the peer host Parameters Values Peer Address 0 None apan Table 5 15 setting for dynamic update of peer host function Remote Host 1 CSE M53N Remote Host 2 Figure 5 11 time chart for dynamic update of peer host Remote host 2 sends data again to CSE M53N CSE M53N updates host 2 to peer host CSE M53N can communicate with remote host 2 Table 5 16 states of each points CSE M53N updates host 1 to peer host The data ABC DE FGH are from the serial port of CSE M53N in the above figure e Sollae Systems Co Ltd 44 http www ezTCP com CSE M53N User Manual Ver 1 7 6 System Management 6 1 Upgrading Firmware 6 1 1 Firmware Firmware is a type of software for operation of CSE M53N If there are needs for adding function or fixing bugs the firmware is modified and released We recommend that users keep use the latest released firmware 6 1 2 Processes 6 Downloading the latest released firmware Download the newest firmware file We update our homepage when a new firmware is released You can find it on our website 6 Entering ISP mode Enter ISP mode to download firmware file to CSE M53N 6 Runa TFTP client and ready to send the EA file Run a TFTP client program ezManager is equipped the client program
14. seconds is passed CSE M53N starts broadcasting the ARP packet again If there is no response until the time is 0 the information is removed If there is response the time is updated 60 seconds again In Ipv6 case it shows ND cache list User can check by the ND cache messages The messages are as follows This means the device is standing by after it sends the INCOMPLETE request message Neighbor Solicitation to MAC and link local address of an opponent in the initial communication This means the device has information about the opponent REACHABLE after it sends Neighbor Solicitation and receives Neighbor Advertisement The device will change into STALE state after some time later The device will change into DELAY state if there is no DELAY response to Neighbor Solicitation In this case CSE M53N will not be able to communicate with the device CSE M53N will resend the request message to the device in PROBE DELAY state CSE M53N will keep sending Neighbor Solicitation until it replies Table 6 4 5 States displyed on ND Cache table TCP IP Connection In this section the same information with TCP STATE is displayed with IP address and port number A difference is that users can terminate TCP connection When right click on a session a small pop up window is created Password This text box is activated when CSE M53N has a password If users want to close TCP connection with right click of mouse on the session this passwo
15. size of two evaluation board is the same According to conditions of soldering components the dimensions might be differed with the above figure Thus we recommend giving some extra spaces about I 2 mm e Sollae Systems Co Ltd 17 http www ezTCP com CSE M53N User Manual Ver 1 7 2 Installation and Test 2 1 IPv6 address With online devices increasing such as smartphones throughout the world the number of available IP addresses has continued to dwindle at an ever faster rate This urgent problem on lack of Ipv4 addresses finally led to the development of an advanced version Ipv6 which has become a key word to effectively settle the matter Ipv6 has a lot of merits on addressing capability packet handling process and security however the devices or software for Ipv4 are not allowed on Ipv6 network due to the different addressing protocol structure For this CSE M53N was developed to be available on both networks by supporting dual stack 2 2 Installation Before testing CSE M53N users should connect both serial and Ethernet port to a PC It will be no problem that the Ethernet connection includes network hubs In this document whole processes are written assume that using it with evaluation board e e LAN RS232 CSE M53N PC Figure 2 1 connection between CSE M53N and a PC Procedures for the test are followed e Sollae Systems Co Ltd 18 http www ezTCP com
16. the value is not 0 the result is the same as above example e Sollae Systems Co Ltd 32 http www ezTCP com CSE M53N User Manual Ver 1 7 A situation that Timeout is set to 5 l S N D Q 9 J TCP IP Serial 299 Remote Host CSE M53N Serial Device 456 3 Bytes AE 5 Seconds Figure 5 3 time chart for a situation that Timeout is set to 5 lt host Processes of the disconnection G The connection has been terminated pm CSE M53N is listening to connection requests Table 5 4 states of each points CSE M53N has sent disconnection request FIN to a remote e Sollae Systems Co Ltd 33 http www ezTCP com CSE M53N User Manual Ver 1 7 5 2 TCP Client In this mode CSE M53N sends request segments to a TCP server with information of Peer Address and Peer Port Once a host is listening the connection will be established After then CSE M53N converts the raw data from the serial port to TCP IP data and sends them to the network and vice versa 5 2 1 Key parameters Peer Address This item should be an address of a remote host who is listening TCP connections Peer Port Peer Port should be the port number which is designated by the remote host Event Byte CSE M53N decides the time to send the connection request frame with this parameter se Right after CSE M53N boots up right after the bytes set to Event Byte have been received from Otherwise the s
17. Address If this option has a valid value the device which has the MAC address is only permitted to access Allowed IP Address This is for qualifying hosts with IP address or range of IP addresses The range is defined by multiplying IP address and Network Mask in bit unit Examples for Ipv4 IP Address Network Mask Allowed IP Address Range 10 1 0 1 255 0 0 0 10 1 0 1 10 255 255 254 10 1 0 1 255 255 255 0 10 1 0 1 10 1 0 254 192 168 1 4 255 255 255 255 192 168 1 4 Table 7 1 examples of defining allowed Ipv4 range Apply to ezManager Apply to ezManager is for applying above two restrictions to ezManager functions like Search Read Write and etc Examples for Ipv6 Ipv6 Address Allowed IP Address Range 2001 DB8 100 2001 DB8 1 2001 DB8 FFFF FFFF FFFF FFFF 2001 DB8 100 128 2001 DB8 100 Table 7 2 examples of defining allowed Ipv6 range 7 2 1 Setting Password A password can be used for protecting CSE M53N from TELNET login or changing environmental parameters by hosts which are not qualified The maximum length is 8 bytes of Alphabet or number When you want to revoke all of these restrictions operate CSE MI53N as ISP mode In the mode all restrictions are removable and communication with ezManager is revoked Souad Sollae Systems Co Ltd 56 http www ezTCP com CSE M53N User Manual Ver 1 7 8 Additional Functions 8 1 Notify Ipv4 Change CSE M53N can be T
18. CP server even though it assigned IP address automatically Using Notify IP Change function CSE M53N sends its IP address with the host name to the designed server There are 3 types DDNS TCP and UDP for this service Dynamic Domain Name Service DDNS CSE M53N supports DDNS service offered by DynDNS Therefore you have to make an account and create host names on the website of DynDNS before you use All about service usage of an account could be changed according to the policy of DynDNS zz DynDNS website http dyn com dns Notify IPv4 Change Protocol Interval Port Data Type S ID S Password Host Name dyndns Lidl Figure 8 1 setting DDNS Select the DDNS dyndns org 40 320 is a fixed value Input the ID of DDNS account Input the password of the account Input a host name which you create on your account TCP UDP In case you have an own server and want to manage the information about changed IP addresses you allowed used TCP UDP for using this option The Data Type can be ASCII or hexadecimal and the Interval is available on configuration Refer to the IP Change Notification document on our website for details Souad Sollae Systems Co Ltd 57 http www ezTCP com CSE M53N User Manual Ver 1 7 8 2 Sending MAC Address Sending MAC Address is a function that CSE M53N sends its MAC address to the remote host right after the connection is established By using this functi
19. D2 HAIC R4 b JOIE D E p HOLE1 NC R5 rs D ae ee a OONF K a lOa loa lou lo RD1 126BAG1A CSE M53N UDE Corp s RJ45 w Pulse Transformer ey FROM MCU S TXD s Me FROM MCU S PIO a gt gt TO MCU S RXD a a FROM MCU S PIO a le FROM MCU S RTS iar gt TO MCU S PIO RTS gt gt TO MCU S CTS SIGNAL INTERFACE BETWEEN USER S MCU Figure 1 6 an Application Circuit http www ezTCP com nie e Sollae Systems Co Ltd CSE M53N User Manual Ver 1 7 1 6 Evaluation Board Evaluation board for CSE M53N is equipped a RS45 connector and a D SUB 9 pin Male connector including the 5V DC power connector ieie 0 0 0 ozto J e YO OO 00000 0 crer ei CSE M53 EVB V1 2 TA Wb L IE 00 I mm H e P 7 RH RL do CR R13 E K erg LAT CRT os a Av nis LP T Las d tam abs 1 oi C CEE ton au O JP4 T R8 3 3V s LINK TXD gt Beie Ds D Muerx Em ZER CSE M53 EVB2 V2 04 amp STS AXD 00 d WD Figure 1 8 EVB2 for CSE M53N Souad Sollae Systems Co Ltd 14 http www ezTCP com CSE M53N User Manual Ver 1 7 ooo oun H O RS485 intercace X Pin 9 TRX 1 TRX Table 1 8 comparison of two evaluation boards 1 6 1 Parts D Power Control Jumper To control supplying the power to the EVB or not Connection I Disconnection LS Figure 1 9 power control jumper DC Power Connector Terminal for connecting
20. DC 5V Power 3 RJ45 Connector Terminal for connecting UTP cable for Ethernet D SUB 9 Male Connector Terminal for connecting 9 pin D SUB connecter for RS 232 JP5 Only used at the Factory When producing the product LED Group 1 RXD D1 Blinks when CSE M53N receives data from the serial port TXD D2 Blinks when CSE M53N sends data to the serial port RTS D3 Green On when CSE M53N is available on receiving data CTS D4 On when CSE M53N is available on sending data TCP On when CSE M53N is connected with a remote host on TCP Table 1 9 LED Group 1 D TTL Port For 3 3V TTL logic level communication e Sollae Systems Co Ltd 15 http www ezTCP com CSE M53N User Manual Ver 1 7 LED Group 2 RXD D6 Blinks when CSE M53N receives data from the Ethernet port Green Blinks 4times at once when any IP addresses have not been Table 1 10 LED Group 2 Reset S W S W for re supplying the power to the EVB JP7 A port for changing modes RS PL Figure 1 10 JP7 for Changing modes di LED Groups 3 PWR D10 Red On when the power is supplied to the EVB Table 1 11 LED Groups 3 3 JP3 A port for enabling or disabling outputs of RS232 line driver Disable this port when using TTL level e Sollae Systems Co Ltd 16 http www ezTCP com CSE M53N User Manual Ver 1 7 1 6 2 Demension 5 5 ex y 3 0 Unit mm A LAD Figure 1 11 Dimension of evaluation board The
21. Embedded Serial to Ethernet Module CSE M53N User Manual Version 1 7 Sollae Systems Co Ltd http www ezTCP com CSE M53N User Manual Ver 1 7 This symbol found on your product or on its packaging indicates that this product should not be treated as household waste when you wish to dispose of it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conserve natural resources For more detailed information about the recycling of this product please contact your local city office household waste disposal service or the retail store where you purchased this product Souad Sollae Systems Co Ltd 1 http www ezTCP com CSE M53N User Manual Ver 1 7 WE TEE 5 SN ee Die de EE ore L Wy eiee Tei ie E 0 OO A eee reer oeeere eee eer eee ererereenree eeererr SEN OR E E E E eh Ke El 6 EE 8 E E SES RE 10 1 5 5 Serial eg gt 1 POO VOA FOTOS SR tees e E A OO CR eiie iniiai i aship iark le Lo EV iua e Be E 14 Eeer 1 RO DO netaacatpodscont notes apeseaen enses easetecestaadee nen dusveoedausiancoeees zdy 2 Ts AA ON ANN TSU cece cance ccd cee cae eee eect siete 18 21
22. Sollae Systems Co Ltd And its distributors entire liability and your exclusive remedy shall be Sollae Systems Co Ltd And its distributors option for the return of the price paid for or repair or replacement of the CSE M53N Sollae Systems Co Ltd And its distributors disclaim all other warranties either expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose with respect to the CSE M53N including accompanying written material hardware and firmware e Sollae Systems Co Ltd 68 http www ezTCP com CSE M53N User Manual Ver 1 7 12 2 2French version Documentation La documentation du bo tier CSE M53N est con ue avec la plus grande attention Tous les efforts ont t mis en ceuvre pour viter les anomalies Toutefois nous ne pouvons garantir que cette documentation soit a 100 exempt de toute erreur Les informations pr sentes dans cette documentation sont donn es a titre indicatif Les caract ristiques techniques peuvent changer a tout moment sans aucun pr avis dans le but d am liorer la qualite et les possibilites des produits 6 Copyright et appellations commerciales Toutes les marques les proc d s les r f rences et les appellations commerciales des produits cit s dans la documentation appartiennent leur propri taire et Fabricant respectif Conditions d utilisations et limite de responsabilit En aucun cas Sollae
23. Systems Co Ltd ou un de ses distributeurs ne pourra tre tenu responsable de dommages quels qu ils soient int grant mais sans limitation les dommages pour perte de b n fice commercial interruption d exploitation commerciale perte d informations et de donn es caract re commercial ou de toute autre perte financi re provenant de l utilisation ou de l incapacit pouvoir utiliser le bo tier CSE M53N m me si Sollae Systems Co Ltd ou un de ses distributeurs a t inform de la possibilit de tels dommages Le boitier CSE M53N est exclusivement pr vu pour un usage en int rieur dans un environnement sec temp r 10 C 40 C et non poussi reux Le bo tier CSE M53N n est pas pr vu ni autoris pour tre utilis en ext rieur ni de fa on embarqu e dans des engins mobiles de quelque nature que ce soit Voiture camion train avion etc ni en milieu explosif ni dans des enceintes nucl aires ni dans des ascenseurs ni dans des a roports ni dans des enceintes hospitaliers ni pour des applications caract re m dical ni dans des dispositifs de d tection et d alerte anti intrusion ni dans des dispositifs de d tection et d alerte anti incendie ni dans des dispositifs d alarme GTC ni pour des applications militaires De m me le bo tier CSE M53N n est pas con u ni destin ni autoris pour exp rimenter d velopper ou tre int gr au sein d applications dans lesquelles une d faillance de
24. arantie 6 Rappel sur l vacuation des quipements lectroniques usages Le symbole de la poubelle barr pr sent sur le bo tier CSE M53N indique que vous ne pouvez pas vous d barrasser de ce dernier de la m me fa on que vos d chets courants Au contraire vous tes responsable de l vacuation du bo tier CSE M53N lorsqu il arrive en fin de vie ou qu il est hors d usage et cet effet vous tes tenu de le remettre un point de collecte agr pour le recyclage des quipements lectriques et lectroniques usag s Le tri l vacuation et le recyclage s par s de vos quipements usag s permettent de pr server les ressources naturelles et de s assurer que ces quipements sont recycl s dans le respect de la sant humaine et de l environnement Pour plus d informations sur les lieux de collecte des quipements lectroniques usag s contacter votre mairie ou votre service local de traitement des d chets e Sollae Systems Co Ltd 70 http www ezTCP com CSE M53N User Manual Ver 1 7 13 History 2013 07 02 1 4 Add Pins LED signal description Lisa Shin ME ES O An O An Application Circuit has been changed Circuit has been changed Lisa Lisa Shin 2014 06 27 Added contents of evaluation board2 2014 07 23 Added contents of telnet command sd exit Souad Sollae Systems Co Ltd 71 http www ezTCP com
25. de TCP connection is not possible when CSE M53N is operating in the ISP or Serial Configuration mode 6 Communication Mode To make TCP connection both a server and client should exist If there are only servers or clients TCP connection can t be established 6 ezICP Firewall When users set the ezTCP firewall with MAC and IP address any hosts can t be reachable to it except for the hosts which have the allowed MAC and IP address Inactivate the option or check the setting is correct 6 Checking the TCP status TCP is a protocol connected one to one without multiple connection function Because of this if a device is on TCP connection other requests are denied If users are in this situation check the network status by connecting on TELNET or using ezManager e Sollae Systems Co Ltd 63 http www ezTCP com CSE M53N User Manual Ver 1 7 9 3 Data Communication Problem on the Serial 6 Connection of Pins Check if the connection of each pin is right Using cables users choose the right type of cable which is suitable for the device C A x CSE M53N GND GND Serial Device Figure 9 1 RS232 connection 6 Setting parameters Check if all the serial port parameters like Baud Rate Data bit Stop bit and Parity are properly set Contact us if you have any questions about above steps or our products e Sollae Systems Co Ltd 64 http www ezTCP com CSE M53N User Manual Ver 1 7 10 Related Material
26. e are displayed here SYSTEM UPTIME Amount of time is displayed since CSE M53N boots up IP4 NETWORK INFORMATION All information about related items with Ipv4 Address is shown here It works even if Souad Sollae Systems Co Ltd 50 http www ezTCP com CSE M53N User Manual Ver 1 7 the IP address is assigned from DHCP or PPPoE IP6 NETWORK INFORMATION All information about related items with Ipv6 Address is shown here It works even if the IP address is assigned from DHCP or PPPoE TCP STATE TCP status of each port is shown this section LISTEN listening TCP connection CLOSE TCP connection is closed SYN_SENT Send SYN segment to make TCP connection ESTABLISHED When TCP connection is established N A In UDP mode Table 6 2 TCP STATE 6 SERIAL STATUS Amount of data in every buffer is displayed The unit is byte The number of data which is received from the COM port The number of data which is sent to the remote host The number of data which is received from the remote host The number of data which is sent to the COM port Table 6 3 SERIAL STATUS Souad Sollae Systems Co Ltd 51 http www ezTCP com CSE M53N User Manual Ver 1 7 ARP ND CACHE TABLE This part shows ARP table on CSE M53N When TCP connection is established or UDP data communication is performed the information of IP and MAC address is automatically stored in the ARP table This information is held for 1 minute When 50
27. ength between 0 4 bytes Transmit Separators without additional bytes Operation Transmit Separators 1 byte Transmit Separators 2 bytes Table 8 1 separator e Sollae Systems Co Ltd 59 http www ezTCP com CSE M53N User Manual Ver 1 7 8 3 3 TELNET COM port Control Option RFC 2217 This option is for sending and receiving serial port states between two devices Users can send and receive control signals like RTS CTS when the states are changed Refer to the Telnet COM Port Control Option document on our website for details 8 3 4 TCP Server Client mode This mode is available on TCP client mode only In this mode you do not need to change the mode for switching active or passive TCP connection Note that the Event Byte option should be set to more than 1 e Refer to the TCP Server Client mode document on our website for details CSE M53N s Data Frame interval is configured 2byte data interval Before sending data from the serial port to LAN CSE M53N gathers data in the buffer If there is no data during the time configured in the 2byte data interval it will send data to the network e Sollae Systems Co Ltd 60 http www ezTCP com CSE M53N User Manual Ver 1 7 8 4 Factory Reset It is a function physically initializes all the setting You can save a setting to user defined ENV region and use it as default values by the factory reset However if you do not use
28. entiere tele tee 57 H NO ee el Le pe Den Verret TET OPP TTP OTe Ver ere ner rre neve Vereen ee De CZ SVC Ee ele S eeen E E E E E E A 58 Ore OO PON Ee COR he e Sollae Systems Co Ltd 3 http www ezTCP com CSE M53N User Manual Ver 1 7 8 3 1 Disable TCP Transmission Delay Oe 59 E T 59 8 3 3 TELNET COM port Control Option RFC 2217 GL 60 O24 TCP Server Client mode d 60 8 4 Factory Reset sse 61 9 Checkit in Jee 62 9 1 Searching problem with ezManager sens 62 OZ COME Hon Fonem avar TOR T 63 9 3 Data Communication Problem on the Serial 64 10 REST S N ACEH AU ses ne a ates arene ears 65 LOL T L BY Og nL 65 LOS HAE sne ee ee 65 11 Technical Support and Warranty esse esse s esse sees 66 NBT 9 15 Te LISE AR Wirt rte tierra nrtertatnrt rte vnrtirt Wrrvirtatertirt Tervrertertert ret 66 dee 66 Ee POTN E 66 11 22 Free Repair Services eee 66 11 2 3 Charged EE 66 12 Precaution and Exemption from Liability ses 67 Ke B E er EE 67 E lee RE 68 laad TAGS VOTO ME 68 Lea ONCE ee a a a ad ae nn de 69 L TE 71 e Sollae Systems Co Ltd 4 http www ezTCP com CSE M53N User Manual Ver 1 7 1 Overview 1 1 Overview Almost all communication devices including PC are using serial transmission In this type devices send and receive data in the order of each byte The serial communication
29. erial port 512 or under Setting to less than 512 bytes is strongly recommended Table 5 5 the operation of Event Byte 1 In addition users can handle the serial data before a TCP connection is established with this parameter PO CSE M53N does not send the data Otherwise CSE M53N sends the data right after a connection is established 512 or under Setting to less than 512 bytes is strongly recommended Table 5 6 the operation of Event Byte 2 Timeout If there is no transmission of data for amount of time which is set to this parameter CSE M53N tries to terminate established TCP connection TCP Server This check option is enable the TCP server client mode In this mode CSE M53N can be operated as a TCP server or client without changing its setting e Sollae Systems Co Ltd 34 http www ezTCP com CSE M53N User Manual Ver 1 7 DNS IP Address DNS IP Address needs when users use host name instead of the IP address 5 2 2 Examples A situation that Event Byte is set to 0 CSE M53N Serial Device Data communication on both sides Table 5 7 states of each points Look at the blue arrow The data 123 from the serial port had sent before the connection is established In this case the data wasn t sent because of the Event Byte is set to 0 e Sollae Systems Co Ltd 35 http www ezTCP com CSE M53N User Manual Ver 1 7 6 A situation that Event Byte is set to 5
30. ich are available to change with AT command ze Including above items rest of parameters can be set by ezManager e Sollae Systems Co Ltd 26 http www ezTCP com CSE M53N User Manual Ver 1 7 4 Operation Modes 4 1 What is the Operation Mode Each of three operation mode of CSE M53N is defined for specific purpose and those are followed 6 Normal mode This mode is for normal data communication and has 4 different connection modes Configuring parameters is also available in this mode 6 Serial configuration mode This mode is for configuring environmental parameters through the RS 232 port ISP mode This mode is for upgrading firmware In addition you can set environmental parameters even though the security options like password are activated by entering this mode 4 2 How to entering each mode Normal Mode j Serial Configuration Power ON Mode ISP Mode Figure 4 1 How to entering each mode Put the ISP pin into GND less than 1 second Reset or g 0 command Transfer a firmware by ezManager G Put the ISP pin into GND more than 1 second Souad Sollae Systems Co Ltd 27 http www ezTCP com CSE M53N User Manual Ver 1 7 4 3 Comparison with each mode configured value RS232 RS422 RS485 Serial Configuration 115 200 N 8 1 RS232 RS422 EE Table 4 1 comparison of each mode 4 4 Normal Mode In normal mode there are four connection types to comm
31. is quite simple to implement but has weaknesses like short distance and hard maintenance CSE M53N lets the serial devices connect to the Internet To communicate on the Internet devices should use TCP IP protocol so CSE M53N processes the converting serial data to TCP IP 1 2 Main Features Very compact module type 20mm x 24mm IPv4 IPv6 dual stack 6 Stateless Stateful DHCPv6 address autoconfiguration 6 High speed UART x 1 3 3V TTL available on RS232 RS422 RS485 extension 6 Industrial temperature range 40 C 85 C 6 Security options SSL3 0 TLS1 0 IP filtering Password 6 Separator settings for packet fragmentation Souad Sollae Systems Co Ltd ae http www ezTCP com CSE M53N User Manual Ver 1 7 1 3 Application Examples 6 1 1 Connection with a PC Serial Device Figure 1 1 1 1 connection with a PC 6 Applied to LANs A Serial Device Network Hub AM Server DC CS Figure 1 2 applied to LANs e Sollae Systems Co Ltd 6 http www ezTCP com CSE M53N User Manual Ver 1 7 Applied to the Internet on Cable Networks 8 f Cable Mode Server PES RK A Serial Device Figure 1 3 applied to the Internet on cable networks Applied to the Internet with an IP Share Router P Server PC 2 9 A Serial Device IP Share Router LAN Server PC 1 ar e Figure 1 4 applied to the Internet with an IP share r
32. l Ver 1 7 e sd sd command is for capturing serial data OP1 means name of the session OP2 means period which has a 10ms unit for the capture Ish gt sd 1 100 com dump start com dump buffering time 1000ms Ish gt tx1 gt 30 31 32 33 34 35 36 37 01234567 XL lt 30 31 32 33 34 35 36 37 01234567 Figure 6 9 sd command exit exit command is used when users close Telnet session Ish gt exit Figure 6 10 exit command In case of the sc command you should use only small letters You can download TCP Client application for a smartphone on our website e Sollae Systems Co Ltd 49 http www ezTCP com CSE M53N User Manual Ver 1 7 6 2 2 Using ezManager Status of CSE M53N can be monitored by Status button on ezManager By using the Refresh Every 1 Second option in the status window the status is automatically updated in every second Status FIRMWARE VERSION A CSE M53N 1 0 Rev C MS3NR 10C BIN B10 SYSTEM UPTIME 0 days 00 20 28 99 IP4 NETWORK INFORMATION MAC Address 00 30 f9 12 10 02 Device IP address 10 1 0 4 Subnet mask 255 0 0 0 Gateway 10 1 0 254 Name Server 0 0 0 0 Link Local fe80 230 f9ff fe 12 1002 Global 200 1 db8 131f 140b 64 Router 200 1 db8 131f 1 Figure 6 11 status window of ezManager FIRMWARE VERSION The name of model name and the version of firmwar
33. luding Ethernet cable In this step we recommend that users connect CSE M53N with PC directly or in the same network hub 6 Checking options of restriction In case that restriction of access is activated the communication with ezManager can be impossible When users are in this situation make CSE M53N operate in ISP mode Souad Sollae Systems Co Ltd 62 http www ezTCP com CSE M53N User Manual Ver 1 7 9 2 Connection Problem over TCP IP 6 Checking parameters related with TCP IP When CSE M53N has a private network IP address personal Computers IP address has to be the same sub network Check if the IP address and local port number are correct In case of a fixed IP address the subnet mask gateway IP address and DNS IP address should be configured TCP Server side TCP Client side Local IP Address Local Port Subnet Mask Local IP Address Peer Address Peer Port Subnet Gateway IP Address DNS IP Address DDNS Mask Gateway IP Address DNS IP Address Table 9 1 major parameters related with TCP IP PING Test Confirm the connection over the network by PING test If the CSE M53N doesn t send any reply from the request check the network environment 6 Firewall In case the networks which need strong security the access may be denied by their firewall Under this circumstance users should ask the person in charge of their network to release ports which will be used Ex TCP 1470 UDP 50005 6 Operation Mo
34. nected with a remote host on TCP OV Table 1 5 STS_LED operation depending on the state e Sollae Systems Co Ltd 11 http www ezTCP com CSE M53N User Manual Ver 1 7 1 5 5 Serial Port Parameters Parameter Value Number 1 Type TTL 3 3V RS232 1 200 921 600 bps RS422 RS485 1 200 230 400 bps Parity NONE EVEN ODD MARK SPACE Data bit 8 7 Stop bit 1 15 2 Flow control NONE RTS CTS Xon Xoff Baud rate Table 1 6 serial port parameters e You need to set parity to use 7 bit as a data bit except NONE 1 5 6 Voltage Features Parameters Description Minimum Maximum Supplied Voltage 3 0 3 6 High level input voltage 2 0 5 0 Low level input voltage 0 3 1 3 High level output voltage 2 4 Low level output voltage 0 4 Table 1 7 voltage features Souad Sollae Systems Co Ltd 12 http www ezTCP com CSE M53N User Manual Ver 1 7 1 5 7 An Application Circuit RI A339 _p vpp_3 3v _B4 nas _psvpp_3 3v EE TP AXN Di VDD 3 3V GON PRE f d 12 1 TP_TXP VDD_3 3V LE ms LED_A L1 TD R1 TP_TXN kk J TAN 9 S 4 I SE LED A L2 TD R2 IP TP EE 5 5 R2 aan 10 7 TP RX sui LAS 6 VDD_3 3V lt STS 1 g LED_B L3 RD R7 fa TP_RXN T F RD LED Wo 7 E T LED_B L4 RD R8 IXD LED f B 8 SE LI 3 LINK LED 9 9 13 CT R3 VDD_3 3V x e x x ER Ee 10 10 7 CH_GND1 H1 4 cle lc Io CH_GN
35. ock units Therefore data that comes through CSE M53N s serial port is collected in block units to send it elsewhere 5 4 1 Key parameters Block Size Byte Block Size Byte is to set the time to gather data in one block Its unit is byte If the data in configured size of the Block Size Byte comes into the serial port CSE M53N will send them as one block to the network The maximum value could be 1460 bytes 6 Dynamic update of Peer host If you set the value of Peer Address and Peer Port to 0 dynamic update of peer host function is activated By using this function CSE M53N can communicate to multiple hosts without additional setting e Sollae Systems Co Ltd 42 http www ezTCP com CSE M53N User Manual Ver 1 7 5 4 2 Examples Block Size 5 F 8 909 S Serial Sg remote Host CSE M53N Serial Device H 123 3 Bytes 2byte time Figure 5 10 time chart for block size is 5 bytes pm CSE M53N Is receiving data from the serial port e CSE M53N Sends 5 bytes as one block based on the Block Size pm Serial device sends data 678 to the CSE M53N Data 678 has arrived CSE M53N sends data from the remote host to the serial device 2byte time has passed EH CSE M53N sends data 678 based on the Data frame Table 5 14 states of each points e Sollae Systems Co Ltd 43 http www ezTCP com CSE M53N User Manual Ver 1 7 Dynamic Update of Peer host This
36. oduct Souad Sollae Systems Co Ltd 67 http www ezTCP com CSE M53N User Manual Ver 1 7 12 2 Exemption from Liability 12 2 1 English version In no event shall Sollae Systems Co Ltd And its distributors be liable for any damages whatsoever including without limitation damages for loss of profit operating cost for commercial interruption loss of information or any other financial loss from the use or inability to use the CSE M53N even if Sollae Systems Co Ltd Or its distributors have been informed of such damages The CSE M53N is not designed and not authorized for use in military applications in nuclear applications in airport applications or for use in applications involving explosives or in medical applications or for use in security alarm or for use in a fire alarm or in applications involving elevators or in embedded applications in vehicles such as but not limited to cars planes trucks boats aircraft helicopters etc In the same way the CSE M53N is not designed or intended or authorized to test develop or be built into applications where failure could create a dangerous situation that may result in financial losses damage to property personal injury or the death of people or animals If you use the CSE M53N voluntarily or involuntarily for such unauthorized applications you agree to subtract Sollae Systems Co Ltd And its distributors from all liability for any claim for compensation
37. ollae Systems Co Ltd 66 http www ezTCP com CSE M53N User Manual Ver 1 7 12 Precaution and Exemption from Liability 12 1 Precaution 6 Sollae Systems is not responsible for product failures occurring due to user s alternation of the product Specifications of the product are subject to change without prior notice for performance improvement 6 Sollae Systems does not guarantee successful operation of the product if the product was used under conditions deviating from the product specifications Reverse engineering of firmware and applications provided by Sollae Systems is prohibited Use of firmware and applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited 6 Do not use the product in an extremely cold or hot place or in a place where vibration Is severe 6 Do not use the product in an environment in which humidity is high or a lot of oil exists 6 Do not use the product where there is caustic or combustible gas 6 Sollae Systems does not guarantee normal operation of the product under the conditions a lot of noise exists 6 Do not use the product for a purpose that requires exceptional quality and reliability relating to user s injuries or accidents aerospace aviation health care nuclear power transportation and safety purposes 6 Sollae Systems is not responsible for any accident or damage occurring while using the pr
38. on a server can identify multiple devices with the information Network Serial Port Option D Don Op d IPv4 Address Search Figure 8 2 setting of Sending MAC Address function D Move to the Option tab Check the Send MAC Address option e You can use Send MAC Address and SSL at the same time Refer to the Sending MAC Address Function document on our website for details e Sollae Systems Co Ltd 58 http www ezTCP com CSE M53N User Manual Ver 1 7 8 3 Serial Port Tab Functions Network Serial Port Option COM1 Serial Port TCP IP Serial Type TTL Communication Mode IRS 232 sl T25 TCP Server 4 Baudrate Peer Address 921600 v Parity Peer Port Local Port None e 1470 1470 Data Bits Event Byte Timeout kd l Stop Bit Data Frame Data Frame Interval 10ms 1 bit Flow Control NONE gt Separator Separator Length Separator HEX DTR DSR lo mj 00708 199 98 TX Interval 2 o Separator Operation Create an ezVSP Port e rancmit d si T kb ein Droit RE HR LA Ho H D Disable TCP Transmission Delay Figure 8 3 setting of Serial port tab functions 8 3 1 Disable TCP Transmission Delay If you use this option CSE M53N sends the data from the serial port to LAN as quickly as possible 8 3 2 Separator Using this function you can control the length of network packets by specific characters select the l
39. ons from unauthorized hosts by using this option Both IP and MAC address are available Souad Sollae Systems Co Ltd 30 http www ezTCP com CSE M53N User Manual Ver 1 7 5 1 2 Examples A situation that Event Byte is set to 0 Figure 5 1 time chart for a situation that Event Byte is set to zero CSE M53N is listening to connection requests Remote host has sent a connection request SYN segment The connection has been established Data communication on both sides Table 5 2 states of each points pw Processes of the connection Look at the blue arrow The data 123 from the serial port had sent before the connection is established In this case the data wasn t sent because of the Event Byte is set to 0 e Sollae Systems Co Ltd 31 http www ezTCP com CSE M53N User Manual Ver 1 7 A situation that Event Byte is set to 1 aE Sa N Serial gt o Serial Device Figure 5 2 time chart for a situation that Event Byte is set to 1 CSE M53N is listening to connection requests Remote host has sent a connection request SYN segment Processes of the connection The data 123 has been sent right after the end of connection processes The connection has been established Table 5 3 states of each points As you can see the data 123 has been sent right after the connection is established because the value of Event Byte had been set to 1 If
40. outer 1 4 Components 6 CSE M53N s Body 6 Evaluation Board for CSE M53N Optional 6 RS232 Cross Cable Optional DC 5V Power Adapter Optional e Sollae Systems Co Ltd 7 http www ezTCP com CSE M53N User Manual Ver 1 7 1 5 Specification 1 5 1 Hardware Input Voltage DC 3 3V Power Current 100M Ethernet 150mA typical consumption 10M Ethernet 200mA typical LL 24 mm x 20 mm x 9 1mm Weight About 2 20 1 x UART 3 3V TTL Serial Port RS232 1 200bps 921 600bps Interface RS422 485 1 200bps 230 400bps 10 Base T or 100 Base TX Ethernet Auto Sensing Network Auto MDI or MDIX cable Auto Rs mme Temperature Operating 40 85 C Storage 40 85 C 0 40 85 C Storage 40 85 C RoHS Compliant Table 1 1 hardware specification 1 5 2 Software TCP UDP IPv4 IPv6 dual stack ICMPv6 TCPv6 UDPv6 Protocol ICMP ARP DHCP PPPoE DNS DDNS Dynamic DNS Telnet SSL Telnet COM Port Control Option RFC 2217 Operation mode Serial Configuration For Configuration via Serial Communicat TCP Client TCP Active Connection ion mode AT Command TCP Passive Active Connection Configuration Utility for MS Windows Major ezManager Supports Downloading F W Utilities Serial to TCP IP Virtual driver for MS Windows Table 1 2 software specification Souad Sollae Systems Co Ltd SE http www ezTCP com CSE M53N User Manual Ver 1 7 1 5 3 Demension The dimension of CSE M53N is foll
41. owed Unit mm 13 STO O OU O CENT CSE M53N Dimension Unit mm Figure 1 5 dimensions of CSE M53N e Sollae Systems Co Ltd 9 http www ezTCP com CSE M53N User Manual Ver 1 7 1 5 4 Pins JP1 JP2 Connector JP1 and JP2 have headers of 2mm pitch There are two triangle marks by the first pin pin number 1 of JP1 and JP2 TP_RXN LAN IN GND TP_RXP LAN IN D TP_TXN LAN OUT TP_TXP LAN OUT S RXD_LED LAN RECEIVE LED Data Received Low XD LED LAN SEND LED Data Transmitted Low INK_LED LINK LED Established Low Table 1 3 JP1 System Reset Low Active r 10 RST Valid time for giving Low signal Input duration over 200us is recommended TXD CTS UART RTS Request To Send Low Output TXDE in RS485 Sending data High TCP Status LED Output L Connected Low Not connected High Status LED It operates depending on the STS LED Output State refer to the Table 1 5 Table 1 4 JP2 U DN 4 U WY Souad Sollae Systems Co Ltd 10 http www ezTCP com CSE M53N User Manual Ver 1 7 State Wave form 3 3V In ISP mode OV 3 3V In Serial Configuration mode OV KA T 250ms 3 3V When any IP addresses have not been assigned J OV gt gt k Ti Th To Ti 130ms T2 1000ms 3 3V When IP addresses have been assigned but not connected with a remote host on TCP OV a T T T 500ms 3 3V Con
42. rd has to be correctly filled 6 Refresh Every 1 Second If this option is checked ezManager send query in every second e Sollae Systems Co Ltd 52 http www ezTCP com CSE M53N User Manual Ver 1 7 IP address Conflict Detection By clicking this button you can find devices which have the same IP address to yours on the network ezTCP Manager v3 2A 20 i IP address conflict information i IP address conflict information IP address type IPv4 Address IP address type IPv6 address Global Number of conflict 3 Number of conflict 3 MAC address 00 30 F2 07 8F E7 MAC address 00 30 F9 11 00 02 Figure 6 13 IP address conflict detection e Sollae Systems Co Ltd 53 http www ezTCP com CSE M53N User Manual Ver 1 7 7 Additional Functions 7 1 SSL 7 1 1 What is the SSL Secure Socekt Layer SSL is cryptographic protocol that provides secure communication on the Internet The SSL works over TCP 7 1 2 How to set the SSL To works for SSL you have to set the SSL related parameters as the following steps Set the SSL check box in the ezManager Check the SSL of the Option tab of the ezManager Option Telnet IPv4 Address Search Send MAC Address Debugging Message SSL Multiple Connection F SSH F Fower Management Figure 7 1 Setting of Option After check the Advanced Menu of the ezManager Click the Certificate V Advanced Menu SetPassword 1 one PING ARP
43. t Figure 6 3 log in to CSE M53N on TELNET Followed commands let users check each state SC Ish gt sc com1 close Table 6 1 Commands for checking states 6 st net st net command displays present IPv4 network states of all sessions CSE M53N Management Console v1 0E Sollae Systems Ish gt st net proto name local address peer address TCP tty 10 1 0 1 23 10 11 0 67 50904 219 ESTABLISHED TCP comi 0 0 0 0 1470 0 0 0 0 0 0 LISTEN Ish gt Figure 6 4 st net command e Sollae Systems Co Ltd 47 http www ezTCP com CSE M53N User Manual Ver 1 7 6 st net6 st net6 command displays present IPV6 network states of all sessions Ish gt st net6 proto name fe80 230 f9ff fel2 1002 23 127 ESTABLISHED fe80 1965 11c7 ea03 9987 55717 Figure 6 5 st net6 command 6 sL SiO st sio command displays the number of bytes for the serial port Ish gt st sio port fmax rbmax rxbuf txbuf rx_count tx_count Figure 6 6 st sio command st uptime st uptime command shows amount of time since CSE M53N boots up Ish gt st uptime 00 05 19 16 up 0 days Ish gt Figure 6 7 st uptime command 6 sc sc command is used when users close a session OP1 means the name of session and OP2 should be close Ish gt sc com1 close Com l closed Ish gt Figure 6 8 sc command e Sollae Systems Co Ltd 48 http www ezTCP com CSE M53N User Manua
44. the region Factory Reset uses a factory default by manufacturer as its default values Using Factory Reset Connect pin ISP to GND input LOW signal Connect pin ISP to GND input LOW signal over 3 seconds Factory Reset will be automatically implemented to default values Disconnect the two pins from GND Reboot 6 Setting custom default values Change the mode to Serial Configuration mode Save custom default values by ezManager or serial configuration commands 3 Input the command below o ae o GO After step current values in the SRAM is saved in user defined ENV region and the values will be always used for Factory Reset e Sollae Systems Co Ltd 61 http www ezTCP com CSE M53N User Manual Ver 1 7 9 Checklist in Trouble When users are in trouble with CSE M53N make sure all the followed steps first 9 1 Searching problem with ezManager 6 Confirming types of configuration utility CSE M53N can be configured by ezManager 6 Stopping Firewall operation Firewalls of personal computer or network block broadcast packets Stop all the firewalls before searching CSE M53N Most of vaccine programs have firewall functions so it can cause some trouble to search CSE M53N Stop these programs before the searching 6 Stable supply of the power Check if the power is supplied continually Connection with the network Make sure that the network connection is fine inc
45. thods for security like filtering password or MAC and IP address In the ISP mode you can revoke all of these When you forgot the password enter the ISP mode to solve the problem e Sollae Systems Co Ltd 29 http www ezTCP com CSE M53N User Manual Ver 1 7 5 Communication Modes 5 1 TCP Server In this mode CSE M53N functions as a TCP server CSE M53N listens to a TCP connection from remote host Once a host tries to connect to CSE M53N it responses that request After the connection is established CSE M53N converts the raw data from the serial port to TCP IP data and sends them to the network and vice versa 5 1 1 Key parameters Local Port This is a server s port number which is used in the TCP connection Event Byte With setting event bytes users can handle the serial data before a TCP connection Is established a a CSE M53N doesn t send the data Otherwise CSE M53N sends the data right after a connection is established 512 or under 512 or under bytes are strongly recommended Table 5 1 Event Byte Timeout If there is no transmission of data for amount of time which is set to this parameter CSE M53N tries to terminate established TCP connection 6 Notify IP Change This function is for notifying information about changed IP address to a server Not only the TCP UDP protocol but Dynamic Domain Name Service DDNS can be used Restriction of Access Users can block TCP connecti
46. to ezManager website for more details e Sollae Systems Co Ltd 20 http www ezTCP com CSE M53N User Manual Ver 1 7 2 3 Simple Test If you press the Simple Test button test program will be shown on your screen 6 Connecting to the CSE M53N via LAN Data Length TCP Client Local Port e a Address 0 a Keep Alive D IPv4 IPv6 Figure 2 3 settings for TCP connection Select TCP Client Input correct IP address and port number of CSE M53N 3 Clink the Connect button In case of TCP Server it will be Listen button 6 Opening RS232 Port RS232 Send 30 31 32 33 34 35 36 37 01234567 A A Data Length 7 Apply Received Data 0 Byte s Parity Data Bits Stop Bit Flow Control NONE 8 wid v NONE v Figure 2 4 opening COM Port GO Select COM port which the CSE M53N is connected to Make sure that all the parameters are the same with CSE M53N Press the Open button Souad Sollae Systems Co Ltd 21 http www ezTCP com CSE M53N User Manual Ver 1 7 Confirm the TCP Connection and COM port status 30 31 32 33 34 35 36 37 01234567 Data Length 8 HS Received Data D Byte s save toad 1 send Dara save Clear rep Client Local Port Peer Address Peer Port lo 10 1 0 1 1470 Keep Alive L J L J IPv4 IPv Connect Disconnect Ee Figure 2 5 TCP Connected message Check the message if the TCP connection is established RS232 Send Receive
47. unication with a remote host In normal mode there are four connection types to communication with a remote host Description Wait connection request from TCP clients Passive Connection TCP Client Send connection request to a TCP server Active Connection AT Command Control connections by AC commands Active Passive Connection Communicate in block units without connection Table 4 2 comparison of communication mode Modifying Serial Name Protocol Connection software of Topology configuration serial devices TCP Client Unavailable Table 4 3 comparison of four communication modes Souad Sollae Systems Co Ltd 28 http www ezTCP com CSE M53N User Manual Ver 1 7 4 5 Serial Configuration Mode This is a mode for setting environmental parameters through RS232 port If you can t use the Ethernet this mode is only way to configure the values Once entering this mode use the Read button on the Serial tab of ezManager Figure 3 4 Refer to the Serial Management Protocol document on our website for details 4 6 ISP Mode You can enter this mode by pressing the ISP button over 1 second There are two special purposes in this mode 4 6 1 Upgrading Firmware ISP mode is for upgrading firmware which is offered by us The upgrade is implemented on Ethernet zc The details are followed in the 6 1 Upgrading Firmware 4 6 2 Revoking Serurity Options CSE M53N offers restriction me

Download Pdf Manuals

image

Related Search

Related Contents

Method and system for testing websites  Chapter 8: Deaccessioning Materials    Westinghouse 7876400 Installation Guide  資料2-4 医療機器研究報告(PDF:1321KB)  TrekAmerica Toons Troubleshooting Want to enter our fantastic  Télécharger - Communauté d`agglomération de la Vallée de  Otmis LB 1100 (barra de luzes) - 0494-MP  téléchargeant le guide 2015 des Bistrots Beaujolais    

Copyright © All rights reserved.
Failed to retrieve file