        EUROSTER 11B
         Contents
1.    The procedure     a  Mount the controller     e using a pair of supplied nylon nail it fasteners  anchors  mount the controller box on a  wall  or any other suitable supporting structure     e using fasteners fix controller cables to the wall     b  Install temperature sensors     e do not immerse sensors in liquids nor install them within stream of flue gases     install boiler temperature sensor at the boiler point specially designed for that purpose  or on an unshielded boiler outlet pipe  as close to the boiler as possible      install tank temperature sensor at the tank point specially designed for that purpose    using hose clips tighten the sensors to their pipes and cover them with thermal  insulation     c  Hook up pump power supply cable     e connect yellow  or yellow green  PE wire with the   terminal     connect blue wire with the N terminal     connect brown wire with the L terminal     d  Verify the connections     check up all cable connections and tighten terminal box lids     e  Hook up the controller     e make sure controller cables are protected against incidental cut off    plug the controller power supply cable into a 230V 50Hz mains socket equipped with a  grounding pin     The controller must not be installed in a place where the ambient  temperature may exceed 40  C     5 CONTROLLER DISPLAY    Elements of the controller display     HYSTERESIS    DYNAMICS CORRECTION       Name of the controlled parameter  displayed while set point value is browsed 
2. EUROSTER 11B USER MANUAL 1    EUROSTER 11B  UTILITY HOT WATER TANK PUMP CONTROLLER       CEO    MANUFACTURER  P H P U  AS  Polanka 8a 3  61 131 Poznan  POLAND  1 INTRODUCTION    Carefully study this user manual to learn how to correctly operate the EUROSTER 11B utility  hot water tank pump controller     2 FIELD OF APPLICATION    EUROSTER 11B is a modern microprocessor based controller used to control utility hot water   UHW  tank pump  It turns the pump ON if tank water temperature drops excessively   Additionally  it protects the tank against chilling out in case of a low temperature or extinction  of the boiler     The EUROSTER 11B controller features the ANTY STOP   function that prevents idle pump rotor against seizing  Once EVUROSTER _ _ 11B  the heating season is over  every 14 days the function    automatically turns ON the pump for 30 seconds  To that end   the controller must be left powered up     3 VISIBLE CONTROLLER ELEMENTS    230 VAC  mains input   230 VAC  power supply to pump   Input for the UHW tank temperature sensor cable  Input for boiler temperature sensor cable   Mains switch   LCD display   Knob    oS       4 INSTALLATION    Hazardous voltages may be present inside the controller and on its cables   Therefore it is expressly forbidden to install the device prior to disconnecting  its mains power supply  Only qualified technicians may install the controller   Do not install any devices showing signs of any mechanical damage     EUROSTER 11B USER MANUAL 
3. fasteners anchors    EUROSTER 11B USER MANUAL    15 CONNECTION DIAGRAM    Diagram presented below is simplified  not every element necessary to correctly operate the  system is shown      EUROSTER 11B       EUROSTER 11B controller  UHW tank temperature sensor  UHW tank   UHW tank pump   CH boiler  heat source    CH boiler temperature sensor  CH system pump   Radiator  heat load     oe    16 ELECTRONIC WASTE MANAGEMENT INFORMATION    We made every effort to get as a long controller lifetime as possible  However  the device is  Subject to natural tear and wear  We ask you to have a controller that will  not meet your requirements any more brought in to an electronic waste  management facility  Electronic waste is collected free of charge by local  distributors of electronic equipment     Inappropriate management of electronic waste may lead to an unnecessary  environment pollution     Cardboard boxes should be disposed of at a paper recycling facility     EUROSTER 11B USER MANUAL    EUROSTER 11B CONTROLLER WARRANTY CERTIFICATE    Warranty terms     1  Warranty is valid for 24 months from the controller sale date    2  Warranty is valid exclusively on the territory of Poland    3  Claimed controller together with this warranty certificate must be supplied to the  seller or directly mailed via Poczta Polska mail operator to the manufacturer    4  Warranty claims shall be processed within 14 business days from the date the  manufacturer has received the claimed device    5  Contro
4. ing or temperature  sensor failure  aborts the function execution     11 TROUBLESHOOTING    a  Device is dead  Burnt mains fuse or ROM failure  Replace the fuse or have the controller serviced     b  Sensor icon on the display blinks     Sh    or    OP    letters next to the icon  Sensor circuit shorted  Sh  or opened  OP   Check replace the sensor cable or ship the  controller  together with the sensor  to service     c  Pump does not operate   Turn on the controller and make sure that pump icon is displayed  If not  check the presets or  restore factory ones  see section B    d  Nie znaleziono   r  d  a odwo  ania   Check pump  connection     d  Controller knob operates erratically  Pulse generator failure  Have the controller serviced     12 COMPATIBILITY WITH STANDARDS CERTIFICATES    The EUROSTER 11B controller meets all requirements of the EMC and the LVD EU Directives   The CE Conformity Declaration is available on the http   www euroster com pl Internet  webpage     13 SPECIFICATIONS    a  Mains 230 V 50Hz  b  Current consumption max  7 MA  1 6 W   c  Output rated load 3A  d  Length of cables  e controller power supply 1 5m  e pump power supply 1 5 m  e UHW tank temperature sensor 5m  e boiler temperature sensor 1 5 m    e  Dimensions  width x height x depth  150 x 90 x 54 mm    14 KIT CONTENTS    a  controller box with 2 temperature sensors  b  sensor hose clips   c  box fasteners anchors   d  this Installation  amp  Operation Manual   e  template to drill holes for 
5. ller may be repaired exclusively by the manufacturer or by other party clearly  authorized by the manufacturer    6  Warranty becomes invalidated in case of any mechanical damage  incorrect  operation and or making any repairs by unauthorized persons    7  This consumer warranty does not exclude  restrict nor suspend any right of the  Buyer ensuing if the product would not meet any of the sale contract terms    sale date serial number date of manufacture Signature stamp    Service phone  48  655 71 20 12    Business entity that issued this warranty certificate   P H P U  AS Agnieszka Szymanska Kaczynska  Chumietki 4  63 840 Krobia  Poland    
6. rature surplus   Heat source temperature must be higher than UHW tank temperature for two reasons    i  to provide good heat transfer efficiency  and  ii  to compensate for heat losses  between the boiler and the tank  The    Boiler tank temperature surplus    preset tells how  much the boiler temperature should exceed the tank temperature in order that the  pump might be engaged  See section 9 for detailed conditions in which the pump is  engaged disengaged       Boiler temperature sensor correction    A constant added to all values measured by boiler temperature  external  sensor to  compensate for differences in respect to water temperature inside the boiler     UHW tank temperature sensor correction  A constant added to all values measured by UWH tank temperature  external  sensor to  compensate for differences in respect to water temperature inside the tank     Pump manual operation  test    Display current pump status commanded by the controller  0 1   pump  disengaged engaged     Press the knob and modify the parameter value to manually control the pump  Press  the knob once more or leave it inactive for 10 seconds to resume automatic mode of  control     ATTENTION  Should a  colliding  value making impossible correct operation of the  controller be preset  then the alarm icon will appear on the display  the colliding  presets will be displayed alternatively  and  after a few seconds  the last correct  combination of presets will be automatically restored     All prese
7. set   Heat source  boiler  temperature sensor icon   Manual operation mode  icon lit while the temperature is manually controlled   Alarm  icon blinks in case of an alarm    State of the heat source  boiler  furnace   animated icon  see description below  Heat source  boiler  temperature   other displayed parameter value   UHW tank temperature   displayed parameter number   UHW tank pump icon lit while the pump is running   UHW tank temperature sensor    O eS Se    EUROSTER 11B USER MANUAL 3    Animated icon that visually presents state of the heat source  boiler  furnace is for  information purposes only  it does not influence operation of the controller in any  way       Normal operation  M  lt   gt  A Supply temperature between 35  C and 90  C    Overheating     lt   gt  M supply temperature  gt  900C      Furnace put out  supply temperature  lt  350C    6 TURNING THE CONTROLLER ON       Turn the controller mains switch  5 in section 3  into the    I    position    gt  Device firmware version No  and compilation date are sequentially displayed for 2 s    gt     AS    letters are blinking on the display while the ANTY STOP functions turns on the  mixing valve  then the pump    gt  State of the system is shown on the display     e If the controller is being turned on for the first time set the desired controller presets   see section 8 below      7 FACTORY  DEFAULT  PRESETS    Proceed as follows to restore factory presets       Press the knob and while holding it depressed t
8. ts are listed below     Preset value  Parameter name    Tank temperature  Pump hysteresis    Boiler temperature sensor correction    Boiler tank temperature surplus    UHW tank temperature sensor correction      as calculated by 0  Pump manual operation  test  the controller  OFF     9 CONTROLLER OPERATION    The controller continuously compares tank temperature with boiler temperature and turns the  pump ON if the former has dropped excessively  Detailed conditions are as follows        The pump is engaged if tank temperature has dropped below the preset minus half of  pump hysteresis Ttank  lt  Tpreset   Hpump 2  The pump is disengaged if the temperature has  exceeded the preset plus half of the hysteresis Ttank  gt  Tpreset   Hpump 2      The pump may be disengaged  without a risk of chilling out the tank  provided that the  difference between the boiler temperature and the tank temperature is at least by 3   C  higher than the preset boiler tank temperature surplus Tohoiler     Ttank  gt  Tsurpus 30C  The  pump should run  to prevent chilling out the tank  until the difference decreases to the  Surplus minus 30C  Tboier     Ttank  lt  Tsurpius 3  C     EUROSTER 11B USER MANUAL 5    10 THE ANTY STOP FUNCTION    The ANTY STOP function turns on the pump immediately after the controller is turned on  then  every 14 days     AS    letters are blinking on the controller display while the function is active     Any alarm generated while the ANTY STOP function is active  overheat
9. urn the controller off and on    Fd     factory defaults  is displayed      Release the knob  Digit O is displayed      Select digit 1 and accept the selection       Check and correct the presets if needed     8 CONTROLLER PRESETS    Shortly after power supply of the controller is turned on  current state of the system is shown  on the display  Turn the knob to the right to enter the preset browse edit mode  General  procedure to edit a preset     1  Turn the knob to select the desired preset  parameter   The controller displays current  value of the selected parameter  top  and its number  bottom      Press the knob  The displayed parameter value starts to blink     Set the desired new value and press the knob to accept it   or   Wait 10 seconds until the displayed parameter value stops blinking in order to abort the  edit procedure  to leave the current value intact     Configuration windows are numbered to facilitate manipulations  User may edit the following  controller parameters  presets      1  Tank temperature  UHW tank temperature that the controller will attempt to maintain manipulating the  pump   ATTENTION  Too low tank temperatures  35 40  C  help to grow various  bacteria within the tank  including the Legionella bacteria     EUROSTER 11B USER MANUAL 4      Pump hysteresis    Difference between the temperature at which the controller turns the pump on and the  temperature at which the controller turns it off  See section 9 below for details     Boiler tank tempe
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung MG23H3185PW Brugervejledning  4861565 Old Style Manual SWBC22 SWBC22-2  Legimus user manual for Iphone and Ipad  model:kabrp21wfiaa user manual  MINDRAY VS-800 Vital Signs Monitor Service Manual  Netgear HA501 User's Manual  Manuel d`utilisation - Bienvenue au site Mélangeurs Vitamix dédié  USO E MANUTENZIONE    Copyright © All rights reserved. 