Contents

1. Install Replace Batteries paragraph on first page Specifications Physical Belt Clip 4 1H x 2 2 W x 0 8 D Transmitter 3 9 H x 2 0 W x 0 69 D Battery Maxell CR2430 or Duracell DL2430 CONTROL WITH WHICH THIS DEVICE IS USED FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM REFER TO THE INSTALLATION INSTRUCTIONS FOR THE FCC STATEMENT This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC ID CFS8DL5804BDV FEDERAL COMMUNICATIONS COMMISSION FCC Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this
2. Syosset New York 11791 Copyright 2004 Honeywell International Inc www honeywell com security K3635V3 9 04 Rev A
3. equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer may find the following booklet prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment LIMITED WARRANTY Honeywell International Inc acting through its Security amp Custom Electronics business Seller 165 Eileen Way Syosset New York 11791 warrants its product s to be in conformance with its own plans a
4. 4BDV 002 VO To Install Replace Batteries 1 Remove the screw from the case back 2 Remove case back by using the blade of a small screwdriver to pry open 3 Place batteries in case back locations see diagram Use CR2430 or DL2430 Lithium battery only 4 Close the case by snapping case front and back together 5 Replace the screw to secure the case N Improperly installing the batteries will cause WARNING damage to the batteries fv N Programming the 5804BDV House ID You must program a House ID number into the unit before you can use it to display the system status The House ID number must be same as the one used in the alarm control The House ID must be in the range of 01 to 31 The default in the 5804BDV is 10 To Enter a House ID 1 Enter House ID mode by pressing the A B and C buttons at the same time until the Red and Green LEDs alternate flashing 2 Enter the House ID number by using the A button to enter the 10 s digit and the B button to enter the 1 s digit Note If the entry is out of range greater than 31 the unit will discard the entry 3 Accept the entry by pressing the D button 4 The unit displays the stored number by flashing the left LED for the 10 s digit and flashing the right LED for the 1 s digit for example for House ID 21 the left LED will flash twice the right LED will flash once 5 The unit will then exit the House ID m
5. Honeywell K3635V3 9 04 Rev A ADEMCO 5804BDV TWO WAY WIRELESS KEY WITH VOICE STATUS INSTALLATION INSTRUCTIONS General Information The 5804BDV is a four button wireless key that permits the user to control the alarm system remotely It is a two way device that can send a command to the alarm system such as to arm or disarm as well as receive status back Status is indicated by two bi color status LEDs and a piezoelectric sounder Each button can be programmed for any zone response type but is typically used for arming disarming panic and output relay operation 1 The 5804BDV must be used in conjunction with one of the following e 5800TM Transmitter Module and a 5881or 5881EN receiver e 6128RF receiver e Lynx control panel 2 Place the 5881 or 5881EN receiver and the 5800TM Transmitter Module in a high centrally located area for best reception The 5800TM module must be located between 1 and 2 feet from the receiver The unit is powered by 2 replaceable Lithium batteries designed to provide up to 2 years of life These batteries are supplied with the unit but not installed see To Install Replace Batteries for more information Red Yellow Green Yellow LED a lt LED 5804BDV 001 V0 5804BDV Front View Belt Clip Loop Assignments e Button A gt Loop3 e Button B gt Loop 2 e Button C gt Loop 4 e Button D gt Loop 1 Note To Remove or Insert the Unit from Belt Clip 540
6. K or Compass downloader software as applicable Be sure to include the loop number of each button during programming see loop assignments on previous page NOTE Do not use the 5804BDV for 24 hour silent alarm as the unit itself is not silent Button C If you choose not to use the C button you must do the following to avoid a Check condition when the button is accidentally pressed 1 Assign this button to a zone 2 After the serial number has been programmed re enter Zone Programming for that zone 3 At the Zone Type prompt enter 00 and press a On VIA 30 controls and below the system will ask whether you want to permanently delete that zone Enter 0 No This will cause the system to retain the serial number but render the button inactive b On VISTA 40 and above continue to press until you see the Enter Zone No prompt again At this point Press 00 and Then press 99 to exit Program mode On VISTA 40 and Above If a button is assigned to zone type 20 Arm Stay 21 Arm Away or 22 Disarm you must assign a user to the button in order for it to operate To assign a user number to the Arm Disarm button 1 Enter 4 digit User Code 8 User No 4 digit new User Code 2 Answer Yes or No to the Open Close Report question Answer Yes to the RF Button question 4 Enter the zone number assigned to the Arm Disarm button The keypad will show the
7. SS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the product s it sells may not be compromised or circumvented that the product s will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the product s will in all cases provide adequate warning or protection Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT S FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT S WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty replaces any previous warranties and is the only warranty made by Seller on this product s No increase or alteration written or verbal of the obligations of this Limited Warranty is authorized Honeywell 165 Eileen Way
8. and sounder activity see the System Status Indications Table If 5804BDV does not receive system status information from the panel for approximately 5 seconds it will shut itself down It will also shut itself down if there is no button activity within 5 seconds of receiving a status update AN WARNING This device may not receive the system status properly if it operates within a few feet of the 5881 RF receiver System Status Indications Table iz eo onaiion speech CSpot On Steady Flashing Green Disarmed Ready to Arm Vao igh Flashing O ndcatos RF vanamision O Red amp Green Alternately eee ee a lt lt Multiple Button Operations N The 5804BDV should not be used for 24 hour silent alarm as the unit itself is not silent WARNING The 5804BDV can generate the same responses as keypad panic key pairs of gt and 1 by depressing A C and B D button pairs respectively You must depress the button pair for at least 2 seconds for the 5804BDV to recognize the button pair command These button pairs allow the user to activate panic fire and medical alarms depending on control panel programming A C Button Pai B D Button Pair 5804BDV 005 VO Low Battery Indication When the unit goes into a low battery condition the yellow LED will not flash when a button is pressed Change both batteries immediately Refer to instructions in To
9. nd specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product s or for product s not having a manufacturer s date stamp for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product s which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise if the product s is altered or improperly repaired or serviced by anyone other than Honeywell factory service Connection of any device s to a communicating bus of a Honeywell security system e g keypad bus polling loop other than those manufactured or approved by Honeywell shall void this warranty For warranty service return product s transportation prepaid to Honeywell Factory Service 165 Eileen Way Syosset New York 11791 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRE
10. ode Example To enter House ID 17 into the unit Enter HID mode Enter HID 17 Press To accept entry HID will be shown Press A B C amp release A button press D button by flashing LEDs buttons until LEDs once press amp release Then exit HID mode flash B button 7 times 5804BDV 004 Vo To View the House ID 1 Enter House ID mode as described in step 1 previous page 2 Depress the D button to view 3 The unit will display the stored number as described in step 4 previous page The unit will then exit House ID mode Programming a House ID in the Alarm Control e On VISTA 40 50P 100 and above use Device Programming mode to enable the RF receiver and enter the House ID number e On VIA 30PSE VISTA 20SE and below go to field 24 and enter the House ID number Programming the Buttons Each 5804BDV is assigned a unique serial number during manufacture Each button on the unit also has a unique loop number that must be programmed into the alarm control during installation Assign each button to an individual zone number and program the Input Type as BR Button Type RF by entering 5 in the control s Zone Programming mode Then input the serial number by one of the following methods e Transmit twice from the device by pressing one of the buttons when prompted for the serial number e Enter the serial number manually through the keypad e Enter the serial number through V LIN
11. summary of user information on its display 5 Test the Arm Disarm button to make sure it operates correctly Adjusting Volume Level This unit is shipped with the volume set to the lowest level To adjust the volume proceed as follows 1 Enter the Volume Level Programming mode by pressing and holding the A B and D buttons simultaneously until the unit s red and green LEDs flash alternately Note that if no button is pressed for 5 seconds the unit will automatically shut down and no change to the volume level is made a Press the A button for low volume level or b Press the B button for medium volume level or c Press the C button for maximum volume level The word Alarm will be heard at the volume level selected 2 Press the D to accept w Volume level affects the life of the battery Use low volume for maximum battery life f Operating the Buttons To Activate a Function To activate a programmed function press and hold the associated button down until the yellow LED flashes then release it To Request System Status Because the 5804BDV is a two way device users can check the system status before arming or disarming their system To check system status press and release any button momentarily The yellow LED will flash after you release the button After a second or two the 5804BDV will display the system status information using a combination of LED