1. analog output no connection to SAT 1 External 24 VDC Power Supply The C 21 only accepts 12 VDC A separate 24 VDC power supply must be used to power the SAT 1 C 21 Accessory Plug special order Email sales ecosensors com Phone 510 574 8300 Fax 510 574 8341 Toll Free 800 472 6626 Service and Maintenance There are no user serviceable parts inside the SAT 1 Contact Eco Sensors at 800 472 6626 or e mail at sales ecosensors com for more information Specifications Indicator Lights Green Amber Red High 360 visibility Audible Alarm None Slow Pulse Fast Pulse 85 dB at 1 m Voltage 24 VDC Current Consumption Lights Green 22 mA Amber 28 mA Red 28 mA Buzzer 40 mA Power Supply 350 mA Mounting Location Indoor use only Size 40 mm X 228 mm 1 57 X 8 97 WARRANTY This product is warranted against defects in materials and workmanship for one year following the date of purchase by the original owner This warranty does not include damage to the product that results from misuse accident dropping modifications or alterations and it does not apply if the instructions in this manual are not followed or if the unit is otherwise used outside its intended specifications If a defect develops during the warranty period Eco Sensors in its sole discretion will repair the instrument or replace it with a new or reconditioned model of equivalent quality In the event of replacement with a new or r
2. BOS SOLS Tr Division of KWJ Engineering SAT 1 Signal Alarm Tower Overview The SAT 1 is a tower light stack with an audible alarm that may be used to indicate various states of operation when connected to Eco Sensors instruments including the OS 4 OS 6 depicted C 30ZX EE 2 OEM 1 OEM 2 and UV 100 The indicator lights and audible alarm are controlled by relay contact closure The SAT 1 requires a 24 VDC 500 mA power supply which is compatible with many Eco Sensors instruments Refer to the User Manual of your Eco Sensors instrument for details The SAT 1 can be mounted on new OS 6 orders at the Eco Sensors factory or ordered separately and installed by the user Hardware is included for direct mount only For more information contact us at 800 472 6626 or e mail at sales ecosensors com Installation and Operation Carefully read and follow the instructions in the Installation Manual included with your product shipment The SAT 1 requires a 24 VDC 500 mA power supply which is compatible with many Eco Sensors instruments Therefore the SAT 1 and a compatible Eco Sensors instrument may both be connected to a single 24 VDC 500 mA power supply Refer to the User Manual of the Eco Sensors instrument for power supply details The indicator lights and audible alarms of the SAT 1 may be configured in a variety of combinations to suit the application and to enhance the functionality of the Eco Sensors instrument The
3. econditioned instrument the replacement unit will continue the warranty of the original unit If the product should become defective during the warranty period please return it through your distributor or call Eco Sensors at 800 472 6626 or e mail at sales ecosensors com to receive return instructions and a Return Materials Authorization RMA number Except as provided herein Eco Sensors makes no warranties express or implied including warranties of merchantability and fitness for a particular purpose Eco Sensors shall not be liable for loss of use of this instrument or other incidental or consequential damages expenses or economic loss or claims for such damage or economic loss RECORD YOUR SERIAL NUMBER HERE KEEP THIS MANUAL AND WARRANTY FOR YOUR RECORDS Eco Sensors is a registered trademark of Eco Sensors Division of KWJ Engineering Inc Eco Sensors Division of KWJ Engineering Inc 2013 Eco Sensors SAT 1 Signal Alarm Tower Email sales ecosensors com Division of KWJ Engineering Inc User Manual Rev 1 1 Phone 510 574 8300 8430 Central Ave Suite C pg 3 Fax 510 574 8341 Newark CA 94560 USA Toll Free 800 472 6626
4. general wiring diagram is shown below Suggested wiring configurations for most Eco Sensors instruments are included on the following page Instrument Relay Contacts Red LED Red es l Amber LED Orange _ Green LED Green i Buzzer 1 Purple f l Buzzer 2 Sky Blue Y Y Power Supply Gray 24 VDC Power Supply Power Supply Eco Sensors SAT 1 Signal Alarm Tower Email sales ecosensors com Division of KWJ Engineering Inc Technical Specification Rev 1 1 Phone 510 574 8300 8430 Central Ave Suite C pg 1 Fax 510 574 8341 Newark CA 94560 USA Toll Free 800 472 6626 Optional Wiring Configurations Optional wiring configurations for the SAT 1 are depicted below for reference only The indicator lights and alarms are not limited to these configurations The user may configure the lights and alarms to suit the application Refer to the instrument s User Manual for details on power supply requirements and relay operation Green light on Yellow light on Red light amp buzzer on OS 6 ozone lt 0 1 ppm ozone 2 0 1 pom ozone gt MAX limit or ozone lt MIN limit for Green light on Yellow light on OS 4 ozone lt 0 1 ppm ozone 2 0 1 ppm the number of minutes specified by FAIL MIN INCR DECR TB6 T85 TB4 FAIL MAX J1 GNO Doto GNO Input N C N N c c AB GENERATOR LARM NTROL 8 1 PPM co 9600 B N 1 dumper to run RS 2352 Out Generator Control om Sensor W
5. hite Black Red Wire DATA GRD 5V _ 12 24 Use either TBS Generator WILL NOT run unless this unit is powered and This is the default configuration for a SAT 1 mounted at the factory C 30ZX Power Supply Green light on Yellow light on ozone lt 0 1 ppm ozone 2 0 1 ppm Power Supply OEM 1 Green light on Yellow light on ozone lt setpoint ozone 2 setpoint 1 120 or 220 VAC factory installed Power Supply External 24 VDC Power Supply The OEM 1 only accepts 12 VDC 120 VAC or 240 VAC A separate 24 VDC power supply must be used to power the SAT 1 UV 100 ozone within setpoints ozone outside setpoints Green light on Red light amp buzzer on E Xeo Sio C XOD 3 Power Supply the SAT 1 and UV 100 a 24 VDC 1A supply is required Eco Sensors Division of KWJ Engineering Inc Newark CA 94560 USA O GROUND TERMINAL A External 24 VDC NET gt Power Supply If the same power supply is used for both SAT 1 Signal Alarm Tower User Manual Rev 1 1 8430 Central Ave Suite C pg 2 Generotor Control 24 VDC Power Supply EE 2 Green light on Yellow light on ozone lt 0 1 ppm ozone 2 0 1 ppm es x er 9 a 24 VDC Power Suppl OEM 2 Green light on Yellow light on ozone lt setpoint ozone 2 setpoint Power Supply C 21 VOC Sensor Red light amp buzzer on ozone 2 alarm setpoint relay contact common Se