Home

KleenSpec CORDLESS ILLUMINATION SYSTEM

image

Contents

1. 4 Utilisation s curitaire du syst me 6 Charging the illuminator 8 Using the illuminator for a pelvic exam 9 Using the illuminator as light source 9 Maintenance ihn2scrcedw iu seras 10 Cleaning and disinfecting 10 Inspecting the system 11 Recycling the system components 11 Troubleshooting 12 Contacts eme ade Le eee see ka ane 12 ADDON Era Moke eee ee en aa 13 Specifications r nione ur oe Reel lat ee ea ences 13 Part MURAD G lS AIR et stan te A etn He 2g tN AA 15 Limited warranty 16 SEVICE POY e ease hoe eed me rte bel Be ode 17 EMC guidance and manufacturer s declarations 18 Directions for use Cordless illumination system 1 Introduction The Welch Allyn KleenSpec 790 series cordless illumination system can be used with or without the KleenSpec 590 series disposable vaginal speculum The cordless illumination system consists of the following items Cordless illuminator Charging station Auxiliary power cord base and power cord optional Intended use When used with the vaginal speculum the cordless illuminator provides illumination during pelvic examinations and other gynecological procedures such as pap smears dilation and curettage D amp C biopsy and electrosurgery The cordless illuminator can be used indepen
2. alcohol If debris builds up on these contacts the charging or auxiliary power functions might be affected Disinfect the illuminator a Following the wipe manufacturer s instructions thoroughly wet the surface of the entire illuminator Using sterile gauze soaked with 70 isopropyl alcohol thoroughly wet the surface of the entire illuminator The treated surface must remain wet for five minutes If needed reapply the solution to keep the surface continuously wet during this time Allow the surface to dry To clean the charging base or auxiliary power cord 1 After using the charging base or auxiliary power cord unplug the power cord Clean the component Following the wipe manufacturer s instructions wipe the surface to completely remove any gross debris Directions for use Cordless illumination system 11 Inspecting the system Examine all components of the cordless illumination system monthly Components include the illuminator charging station and auxiliary power cord If any component is worn or damaged replace it with the Welch Allyn approved part For ordering information see Part numbers on page 15 Recycling the system components Within the EU Do not dispose of this product as unsorted municipal waste x Prepare it for reuse or separate collection as specified by Directive 2002 96 EC of the European Parliament and the Council of the European Union on Waste Electronic and Electrical Equipme
3. fonctionnement appelez Welch Allyn et d crivez le probl me de mani re pr cise Mise en garde Cet appareil est conforme aux normes actuelles obligatoires sur les interf rences lectromagn tiques II ne devrait pr senter aucun probl me pour les autres quipements et ne devrait pas tre affect par d autres appareils Par mesure de pr caution vitez d utiliser cet appareil proximit d autres quipements Mise en garde N utilisez que des pi ces approuv es par Welch Allyn Voir Part numbers la page 15 8 Welch Allyn Charging the illuminator Charge the illuminator before using it the first time or whenever its low charge indicator turns on LED gt Power switch Low charge indicator On battery low To charge the illuminator 1 If LED is lit turn power switch off 2 Connect charging base to AC power 3 Place the illuminator either direction into the charging station Full charging takes 6 to 8 hours Status indicator Off no AC power Green AC power Amber illuminator inserted charging Full charging takes 6 to 8 hours 4 Remove the charged illuminator when you are ready to use it It is safe to leave the illuminator in the charging station after it is charged Directions for use Cordless illumination system 9 Using the illuminator for a pelvic exam 1 Fully insert the illuminator into a 590 series speculum a The LED automatically turns on 2 Conduct
4. pas directement le faisceau lumineux AVERTISSEMENT Le syst me d clairage peut d gager de la chaleur apr s une utilisation prolong e Les dur es d op ration maximales Illuminateur avec sp culum lt 10 minutes de marche gt 5 minutes d arr t entre les utilisations Illuminateur seul lt 2 minutes de marche gt 5 minutes d arr t entre les utilisations Le syst me d clairage peut causer des br lures cutan es si vous y touchez apr s une utilisation prolong e Pour viter les risques d incendie ne d posez pas le syst me d clairage sur une surface inflammable lorsque la DEL est allum e Le syst me d clairage ne devrait pas tre utilis en pr sence d un m lange d anesth sique inflammable et de l air ou encore d oxyg ne ou d oxyde nitreux Cela pourrait causer une explosion AVERTISSEMENT La prise lectrique doit tre correctement mise la terre afin d viter les chocs lectriques Vous ne pouvez tre certain de la mise la terre que si l appareil est branch dans une prise utilis e par les h pitaux ou de qualit hospitali re AVERTISSEMENT Le syst me d clairage ne devrait pas tre utilis pour les examens des yeux AVERTISSEMENT Le syst me d clairage ne devrait pas tre utilis pour effectuer un diagnostic AVERTISSEMENT Le syst me d clairage est con u pour tre utilis par des professionnels m dicaux form s Directions for use A Cordless illuminat
5. the examination 3 If the LED turns off do not remove the speculum Do either of these things e Leave the illuminator in place and use an external light source or e Connect the auxiliary power cord to AC power Hold the speculum in place and remove the illuminator Connect the auxiliary power cord to K b illuminator b Reinsert the illuminator 4 When finished remove the speculum and then remove the illuminator The LED automatically turns off Using the illuminator as light source To use the illuminator as a light source slide the power switch to turn it on all the way down and off all the way up Power switch Note For operation time limits see Intermittent operation on page 15 10 Welch Allyn Maintenance Cleaning and disinfecting Use CaviWipe wipes for both cleaning and disinfecting EPA approved intermediate level disinfectant appropriately labeled as effective against TB mycobacterium tuberculosis per AAMI TIR 12 2004 section 5 2 3 To clean and disinfect the illuminator 1 2 Caution Use only the cleaning and disinfection methods described in this manual Clean the illuminator prior to disinfection After using the illuminator unplug any power cords Clean the illuminator a Following the wipe manufacturer s instructions wipe the entire unit to completely remove any gross debris Gently wipe the gold contacts on the bottom with 70
6. Compliance Electromagnetic environment guidance test test level level Portable and mobile RF communications equipment should be used no closer to any part of the 790 series cordless illumination system including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Conducted 3 Vrms 3 Vrms d 117 P RF IEC 150 kHz to 61000 4 6 80 MHz Radiated 3 V m 3 V m d 1 17 P 80 MHz to 800 MHz RF IEC 80 MHz to 61000 4 3 2 5 GHz d 2 33 P 800 MHz to 2 5 GHz where Pis the maximum output power rating of the transmitter in watts according to the transmitter manufacturer and dis the recommended separation distance in meters Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol e Directions for use Cordless illumination system 21 Table 3 Electromagnetic immunity continued Note 1 At 80 MHz and 800 MHz the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 4 Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and lan
7. Contact Welch Allyn Technical Support THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILTY AND FITNESS FOR A PARTICULAR PURPOSE WELCH ALLYN S OBLIGATION UNDER THIS WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT OF PRODUCTS CONTAINING A DEFECT WELCH ALLYN IS NOT RESPONSIBLE FOR ANY INDIRECTOR CONSEQUENTIAL DAMAGES RESULTING FROM A PRODUCT DEFECT COVERED BY THE WARRANTY Directions for use Cordless illumination system 17 Service policy All repairs on products under warranty must be performed or approved by Welch Allyn Unauthorized repairs will void the warranty In addition whether or not covered under warranty any product repair shall exclusively be performed by Welch Allyn certified service personnel If the product fails to function properly or if you need assistance service or spare parts contact Welch Allyn Before contacting Welch Allyn try to duplicate the problem and check all accessories to ensure that they are not causing the problem When calling please be prepared to provide e Product name and model number and complete description of the problem e Serial number of your product if applicable e Complete name address and phone number of your facility e For out of warranty repairs or spare parts orders a purchase order or credit card number e For parts orders the required spare or replacement part numbers
8. If your product requires warranty extended warranty or non warranty repair service please call Welch Allyn A representative will assist you troubleshooting the problem and will make every effort to solve it over the phone avoiding potential unnecessary returns In case a return cannot be avoided the representative will record all necessary information and will provide a Return Material Authorization RMA number as well as the appropriate return address An RMA number must be obtained prior to any return If you have to return goods for service follow these recommended packing instructions e Remove all hoses cables sensors power cords and ancillary products as appropriate before packing unless you suspect they are associated with the problem Wherever possible use the original shipping carton and packing materials Include a packing list and the Welch Allyn Return Material Authorization RMA number It is recommended that all returned goods be insured Claims for loss or damage to the product must be initiated by the sender 18 Welch Allyn EMC guidance and manufacturer s declarations Table 1 Emissions for all EQUIPMENT and SYSTEMS The 790 series cordless illumination system is intended for use in the electromagnetic environment specified below The customer or user of the 790 series cordless illumination system should assure that it is used in such an environment Emissions test Compliance Electromagnetic e
9. KleenSpec 790 Series Cordless Illumination System for the 590 Series Vaginal Speculum Directions for Use Welch Allyn Advancing Frontline Care Copyright 2007 Welch Allyn All rights are reserved No one is permitted to reproduce or duplicate in any form this manual or any part thereof without permission from Welch Allyn Caution Federal US law restricts sale of the device identified in this manual to or on the order of a licensed physician Welch Allyn assumes no responsibility for any injury or for any illegal or improper use of the product that may result from failure to use this product in accordance with the instructions cautions warnings or indications for use published in this manual Welch Allyn and KleenSpec are registered trademarks of Welch Allyn CaviWipe is a registered trademark of Metrex Research Corporation Caution Changes or modifications not expressly approved by Welch Allyn could void the purchaser s authority to operate the equipment Patents pending Mat Number 707021 Ver E Welch Allyn 4341 State Street Road PO Box 220 Skaneateles Falls NY 13153 0220 www welchallyn com Printed in USA WelchAllyn Contents INEFOCUCHON ES och his Bre sO eee oa es 1 Intended USE by BE Ree eh ed dn Ee EE RE 1 CONtAINGICATIONS reri roas a mme nee te eee AEA 1 User profile Te Tr ties cmt eh min OA ees 2 SVMIDO S erate tah A Matte Std A Reale Hy call nd 2 Using the system safely
10. d mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the 790 series cordless illumination system is used exceeds the applicable RF compliance level above the 790 series cordless illumination system should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the 790 series cordless illumination system b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m 22 Welch Allyn Table 4 Recommended separation distances between portable and mobile RF communications equipment and the 790 series cordless illumination system The 790 series cordless illumination system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or user of the 790 series cordless illumination system can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the 790 series cordless illumination system as recommended below according to the maximum output power of the communications equipment Rated max Separation
11. dent of the speculum as a general purpose light source Contraindications The 790 series illuminator either by itself or in conjunction with a 590 series speculum is not intended to be used for eye examinations The 790 series illuminator either by itself or in conjunction with a 590 series speculum is not intended to be used for diagnosis 2 Welch Allyn User profile The intended users of the illuminator are medical professionals who are qualified to perform a pelvic examination Symbols The symbols illustrated on the following pages may appear in this manual or on the illuminator charging station auxiliary power cord packaging or shipping container Table 1 Documentation symbols WARNING In this manual this symbol and WARNING indicate A conditions or practices that could lead to Illness injury or death Caution In this manual this symbol and Caution indicate A conditions or practices that could damage the equipment or other property On the product this symbol means consult A accompanying documentation Table 2 Shipping storing and environment symbols This end up wets Keep dry y Fragile Relative humidity limit C Temperature limits 20 C Directions for use Cordless illumination system Table 3 Certification symbols 3 CE Meets essential requirements of European Medical Device Directive 93 42 EEC European Regulatory Manager Welch All
12. distance according to frequency of transmitter m output power of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz W d 1 17 P d 1 17 P d 2 33 P 0 01 0 117 0 117 0 233 0 1 0 37 0 37 0 74 1 1 17 1 17 2 33 10 3 70 3 70 7 37 100 11 70 11 70 23 30 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where Pis the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer Note 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Welch Allyn 4341 State Street Road PO Box 220 Skaneateles Falls NY 13153 0220 USA 1 800 535 6663 1 315 685 4560 www welchallyn com Advancing Frontline Care Mat Number 707021 Ver E
13. e nearest Welch Allyn representative USA 1 800 535 6663 Australia 6129 638 3000 1315 685 4560 800 074 793 Canada 1 800 561 8797 China 86 216 327 9631 European Call Center 353 46 906 7790 France 3315 569 5849 Germany 49 747 792 7186 Japan 8133 219 0071 Latin America 1 305 669 9003 Netherlands 3115 750 5000 Singapore 656 419 8100 South Africa 2711 777 7555 United Kingdom 44 207 365 6780 Sweden 46 85 853 6551 Directions for use Appendix Specifications Cordless illumination system 13 Item Specification Auxiliary power cord transformer Classification Input Output Category Charging station transformer assification Input Output Category o U S amp Canada International Class type BF applied part Class II type BF applied part 120 V 60 Hz 90 264 VAC 50 60 Hz 200 mA 5 VDC 300 mA 5 VDC 300 mA Not AP APG equipment Not AP APG equipment U S amp Canada International Class Class Class Il 120 V 60 Hz 230 V 240 V in Australia 50 Hz 9 8 VDC 150 mA 7 5 9 2 VDC 200 mA Not AP APG equipment Not AP APG equipmen Power cord length Auxiliary power cord 305 cm 120 in Charging station 92 cm 36 in Weight Illuminator 48 g 0 1 Ib Charging station base and 142 g 0 31 lb power cord Auxiliary power cord 290 g 0 64 Ib Battery cell Capacity 700 mAh Voltage 37V Chemistry Li ion single lithium ion Protection against ingress
14. ion system 7 AVERTISSEMENT Un bloc d alimentation et ou un cordon d alimentation destin s une utilisation avec ce produit seulement sont fournis avec le produit Le bloc d alimentation et ou le cordon d alimentation n ont pas t test s et approuv s pour une utilisation avec d autres produits qui pourraient tre munis des m mes connecteurs d alimentation Si vous n avez plus le bloc d alimentation et ou le cordon d alimentation originaux veuillez communiquer avec Welch Allyn pour obtenir des pi ces de remplacement Mises en garde g n rales Les mises ne garde suivantes s appliquent l utilisation du syst me d clairage sans fil en g n ral Les nonc s de mise en garde qui s appliquent des proc dures particuli res comme les examens pelviens sont abord es dans les sections correspondantes de ce manuel Les nonc s de mise en garde indiquent des conditions ou des pratiques qui pourraient endommager les quipements ou la propri t Mise en garde Le syst me d clairage sans fil pourrait tre consid r risque biologique apr s utilisation Conformez vous aux bonnes pratiques hospitali res Voir Cleaning and disinfecting la page 10 Mise en garde Le syst me d clairage sans fil la borne de recharge et le cordon d alimentation auxiliaire ne sont pas prot g s contre les infiltrations de liquide Mise en garde Cet appareil ne contient aucune pi ce entretenir En cas de mauvais
15. mes e To avoid fire do not place illuminator onto a flammable surface if LED is on Illuminator is not suitable for use in the presence of a flammable anesthetic mixture with air or oxygen or nitrous oxide An explosion may result properly grounded Grounding reliability is achieved only when connected to hospital use or hospital grade receptacles WARNING To prevent shock hazards the power outlet must be WARNING The illuminator is not intended to be used for eye examinations WARNING The illuminator is not intended to be used for diagnosis WARNING The illuminator is intended to be used by trained medical professionals Directions for use A Cordless illumination system 5 WARNING This product comes with a power supply and or power cord that is intended for use only with this product The power supply and or power cord have not been tested and approved for use with other products that may have the same power connectors If you cannot locate the original power supply and or power cord please contact Welch Allyn to obtain replacement parts General cautions The following caution statements apply to use of the cordless illumination system in general Caution statements that apply specifically to particular procedures such as pelvic examinations appear in the corresponding sections of the manual Caution statements indicate conditions or practices that could damage the equipment or other property Cauti
16. nt WEEE If this product is contaminated this directive does not apply For more specific disposal information see www welchallyn com weee or contact Welch Allyn Outside the EU When the product reaches its end of life recycle the components according to national state and local regulations or return the product to Welch Allyn 12 Welch Allyn Troubleshooting If you try these suggestions and still have problems contact Welch Allyn Problem Probable causes amp solutions LED does not light Battery is low Charge the illuminator Illuminator is not seated correctly in speculum Insert illuminator fully into speculum LED does not light when the auxiliary power cord is attached Auxiliary power cord is not plugged in Plug the auxiliary power cord into an AC outlet Auxiliary power cord is not seated properly Plug the cord into the illuminator properly LED does not automatically turn off when removing the illuminator from the speculum Power switch is damaged or blocked Clean the switch area If the problem continues replace the illuminator Illuminator does not charge in the charging base Charging base is not plugged in Connect charging base to AC power Illuminator is not seated properly in charging base Reinsert the illuminator into the charging base and verify that the status indicator glows amber Contacts For information about any Welch Allyn product call th
17. nvironment guidance RF emissions Group 1 The 790 series cordless illumination system uses RF energy CISPR 11 only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions Class B The 790 series cordless illumination system is suitable for CISPR 11 use in all establishments including domestic and those _ directly connected to the public low voltage power supply Harmonic emissions Class A network that supplies buildings used for domestic IEC 61000 3 2 purposes Voltage fluctuations Complies flicker emissions IEC 61000 3 3 Directions for use Cordless illumination system 19 Table 2 Immunity for all EQUIPMENT and SYSTEMS The 790 series cordless illumination system is intended for use in the electromagnetic environment specified below The customer or user of the 790 series cord that it is used in such an environment ass illumination system should assure Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic 6 kV contact 6 kV contact Floors should be wood concrete or discharge ESD 8kV air 8kV air ceramic tile If floors are covered with IEC 61000 4 2 synthetic material the relative humidity should be at least 30 Electrical fast 2 kV mains 2 kV mains Mains power quality should be that of transien
18. of IPX water per IEC 60529 illuminator auxiliary power cord charging station Operating conditions Temperature Relative humidity Altitude 10 C to 35 C 50 F to 95 F 30 to 75 noncondensing 700 to 1060 hPa 14 Welch Allyn Item continued Specification continued Shipping and storage conditions Temperature Relative humidity Altitude 20 C to 49 C 4 F to 120 F 15 to 95 noncondensing 500 hPa to 1060 hPa Intermittent operation Illuminator with speculum Illuminator alone lt 10 minutes on gt 5 minutes off between uses lt 2 minutes on gt 5 minutes off between uses Safety EMC and regulatory compliance CAN CSA C 22 2 No 601 1 M90 including amendments 1 amp 2 EN IEC 60601 1 EN IEC 60601 1 2 EN IEC 60825 1 UL 60601 1 AS NZS CISPR11 LED radiation output lt 6 67 mW at 400 700 nm wavelengths Directions for use Part numbers Cordless illumination system 15 Item Order Number Cordless illuminator system U S amp Canada 79910 with charging station International 79915 Cordless illuminator system U S amp Canada 79920 ad with charging station and auxiliary power cord International 79925 Cordless illuminator U S amp Canada 79900 Charging station base and power cord U S amp Canada 73910 International 73915 Auxiliary power cord U S amp Canada 75910 In
19. on The cordless illuminator could be a biohazard after use Follow good hospital practices See Cleaning and disinfecting on page 10 Caution Cordless illuminator charging station and auxiliary power cord are not protected from the ingress of liquid Caution There are no userserviceable parts inside the device In case of a malfunction call Welch Allyn and precisely describe the problem Caution This device complies with current required standards for electromagnetic interference and should not present problems to other equipment or be affected by other devices As a precaution avoid using this device in close proximity to other equipment Caution Use only Welch Allyn approved parts See Part numbers on page 15 Welch Allyn Utilisation s curitaire du syst me Avant d utiliser le syst me d clairage sans fil vous devez bien lire et comprendre les renseignements de s curit suivants Avertissements g n raux Les avertissements suivants s appliquent l utilisation du syst me d clairage sans fil en g n ral Les avertissements qui s appliquent des proc dures particuli res comme le nettoyage sont abord s dans les sections correspondantes de ce manuel Ces avertissements indiquent des conditions ou des pratiques qui pourraient causer des maladies des blessures ou des d c s A AVERTISSEMENT Rayonnement de la DEL Produit DEL de classe 2 Pour viter les blessures aux yeux ne regardez
20. t EFT 1 kV 1 0 Not applicable a typical commercial or hospital burst environment IEC 61000 4 4 Surge 1 kV differential 1 kV differential Mains power quality should be that of IEC 61000 4 5 2 kV common 2 kV common a typical commercial or hospital environment Voltage dips short gt 95 dip in gt 95 dip in Mains power quality should be that of interruptions and 0 5 cycle 0 5 cycle a typical commercial or hospital voltage variations environment If the user of the 790 on power supply 60 dip in 60 dip in series cordless illumination system input lines 5 cycles 5 cycles requires continued operation during IEC 61000 4 11 power mains interruptions It is 30 dip for 30 dip for recommended that the 790 series 25 cycles 25 cycles cordless illumination system be powered from an uninterruptible gt 95 dip in gt 95 dip in power supply or battery 5 seconds 5 seconds Power frequency 3 A m 3 A m Power frequency magnetic fields 50 60Hz should be at levels characteristic of a magnetic field typical location in a typical IEC 61000 4 8 commercial or hospital environment 20 Table 3 Electromagnetic immunity Welch Allyn The 790 series cordless illumination system is intended for use in the electromagnetic environment specified below The customer or user of the 790 series cordless illumination system should assure that it is used in such an environment Immunity IEC 60601
21. ternational 75915 Specify country and voltage 16 Welch Allyn Limited warranty Welch Allyn warrants that the KleenSpec vaginal speculum cordless illumination system products meet the labeled specifications of the Products and will be free from defects in materials and workmanship that occur within one year after the date of purchase The date of purchase is the date specified in our records if you purchased the Product directly from us or 30 days after the date on which the Product was sold to the dealer from whom you bought the Product as documented in our records This warranty does not cover damage caused by 1 handling during shipping 2 use or maintenance contrary to labeled instructions 3 alteration or repair by anyone not authorized by Welch Allyn and 4 accidents If a Product or accessory covered by this warranty is determined to be defective because of defective materials components or workmanship and the warranty claim is made within the warranty period described above Welch Allyn will at its discretion repair or replace the defective Product or accessory free of charge If your Product requires repairs covered by this warranty upon your request Welch Allyn will loan to you at no cost a substitute Product for use until your repaired Product is returned You must obtain a return authorization from Welch Allyn to return your Product before you send it to Welch Allyn s designated service center for repair
22. yn LTD Navan Business Park Dublin Road Navan County Meath Republic of Ireland Tel 353 46 90 67700 Fax 353 46 90 67755 Complies with applicable U S and Canadian medical safety standards EMC framework of Australia Warning LED beam Caution hot surface Type BF applied part Alternating current Direct current Double insulation Not protected from the ingress of liquid Recycle the product separately from other disposables See Recycling the system components on page 11 Power plug 4 Welch Allyn Using the system safely Before using the cordless illumination system you must read and understand the following safety related information General warnings The following warning statements apply to use of the cordless illumination system in general Warning statements that apply specifically to particular procedures such as cleaning appear in the corresponding sections of the manual Warning statements indicate conditions or practices that could lead to illness injury or death WARNING LED radiation Class 2 LED product To avoid eye injury do A not stare into beam WARNING The illuminator may generate heat after prolonged use A e Operation time limits Illuminator with speculum lt 10 minutes on gt 5 minutes off between uses Illuminator alone lt 2 minutes on gt 5 minutes off between uses Illuminator could be harmful to skin if touched after being on for extended ti

Download Pdf Manuals