1. X1 SPT1 CHANI 10 1 NOTHING TEXT X2 SPZ1 CHANI 1 1 NOTHING FP X3 SPT2 CHANI 10 1 NOTHING TEXT X4 SPZ2 CHANI 1 1 NOTHING FP X5 SPT3 CHANI 10 1 NOTHING TEXT X6 SPZ3 CHANI 1 1 NOTHING FP X7 SPT4 CHANI 10 1 NOTHING TEXT X8 SPZ4 CHANI 1 1 NOTHING FP X9 SPT5 CHANI 10 1 NOTHING TEXT X10 SPZ5 CHANI 1 1 NOTHING FP state bytes X11 STAI CHAN 1 1 NOTHING X12 STA2 CHAN 1 1 NOTHING X13 STA3 CHAN 1 1 NOTHING X14 STA4 CHAN 1 1 NOTHING X15 STAS CHAN 1 1 NOTHING X16 STA6 CHAN 1 1 NOTHING X17 STA7 CHAN 1 1 NOTHING X18 STA8 CHAN 1 1 NOTHING v STA of analyzer with an index actual values SPW of measured substances with an index X21 SPW1 CHAN 1 1 NOTHING_FP X22 SPW2 CHAN 1 1 NOTHING_FP X23 SPW3 CHAN 1 1 NOTHING_FP X24 SPW4 CHAN 1 1 NOTHING_FP X25 SPW5 CHAN 1 1 NOTHING_FP time pauses CZO and CZK without an index X31 CZO CHANI 1 1 NOTHING X32 CZK CHANI 1 1 NOTHING results after calibration zero drift DZK sensibility drift DWK without an index ASKOM Gliwice August 2005 700 Driver of MAIHAK Analyzer Protocol asix4 X42 DZK1 CHANI 1 1 NOTHING FP X43 DWK1 CHANI 1 1 NOTHING FP X44 DZK2 CHANI 1 1 NOTHING FP X45 DWK2 CHANI 1 1 NOTHING FP status of temperature compensation SKT with an index X51 SKT1 CHAN
2. 1 1 NOTHING X52 SKT2 CHAN 1 1 NOTHING X53 SKT3 CHAN 1 1 NOTHING X54 SKT4 CHAN 1 1 NOTHING X55 SKT5 CHAN 1 1 NOTHING gt identifier of analyzer IDA without an index X61 IDA CHANI 42 1 NOTHING_TEXT serial number of analyzer IDA without an indexes X62 NRS CHANI 20 1 NOTHING_TEXT menu language of analyzer IDA without an index X63 MNU CHANI 1 1 NOTHING BYTE state of zero calibration gas pump 1 and 2 SPKZ with an index X70 SPKZ1 CHANI 1 1 NOTHING X80 SPKZ2 CHANI 1 1 NOTHING nominal values of zero calibration gases 1 and 2 NSPZ with an index and element X71 NSPZ1 1 CHAN 1 1 NOTHING_FP X72 NSPZ1 2 CHANI 1 1 NOTHING_FP X73 NSPZ1 3 CHANI 1 1 NOTHING_FP X74 NSPZ1 4 CHANI 1 1 NOTHING_FP X75 NSPZ1 5 CHANI 1 1 NOTHING_FP X81 NSPZ2 1 CHAN 1 1 NOTHING _ X82 NSPZ2 2 CHANI 1 1 NOTHING _ X83 NSPZ2 3 CHAN 1 1 NOTHING _ X84 NSPZ2 4 CHANI 1 1 NOTHIN X85 NSPZ2 5 CHANI 1 1 NOTHIN QOOQQ0Q coe m m Mes a a Ma Ma ia status of standard calibration gas pump 3 6 SPKW with an index X90 SPKW3 CHANI 1 1 NOTHING X100 SPKW4 CHANI 1 1 NOTHING X110 SPKW5 CHANI 1 1 NOTHING X120 SPKW6 CHANI 1 1 NOTHING aoe rated values of standard calibration gases 3 6 NSPW with an index and element X91 NSPW3 1 CHAN 1 1 NOTHING _FP
3. index within the type for some types of variables element element within the index for some types of variables Types which use no index in parentheses a type of raw variable value is given CZK time of calibration measure WORD CZO delay time WORD IDA analyzer identifier up to 40 characters BYTE MNU menu language identifier BYTE NRS analyzer serial number BYTE PGB measure introducing of tested gas to the analyzer WORD SPKK state of a calibration tray pump WORD Types which need to give an index in parentheses a type of raw variable value is given DWK sensibility drift after calibration FLOAT DZK zero point drift of measure substance after calibration FLOAT NSKK rated value of measured substance in calibration tray FLOAT PGKW measuring introducing of standard calibration gas in the analyzer WORD PGKZ measuring introducing of zero calibration gas to the analyzer WORD SKT compensation of measured substance temperature WORD SPKW status of a standard calibration gas pump WORD SPKZ status of a zero calibration gas pump WORD SPT name of measure substance BYTE SPW current values of measured substances FLOAT SPZ end value of measuring range of measured substance FLOAT STA actual analyzer state WORD Types which need to give an index and an element in parentheses a type of raw variable value is given NSPW rated value of measured s
4. an internal status byte of the analyzer is transferred The content of this byte decides about the status of data which are transferred in a given answer from the analyzer If the byte has a value of 0 then the variables receive a correct status otherwise they receive an error status The use of the item IGNORE_STATUS_CHARACTER with a value of YES causes that a correct status is assigned to the variables irrespectively of the status byte content Default value by default the item has a value of NO v RECV_TIMEOUT station_no number Meaning the item RECV_ TIMEOUT allows to specify a waiting time for arriving the first character of an answer sent from a specified analyzer After passage of this time it is assumed that a given analyzer does not work correctly and the transmission session ends with an error Default value by default it is assumed that the maximal waiting time for the first character of an answer is equal to 1000 milliseconds Parameter station_no number AK ID of the analyzer number time in milliseconds from 100 to 5000 v CHAR_TIMEOUT station_no number Meaning the item allows to determine a maximal time between successive characters of answer from a given analyzer After passage of this time it is assumed that a given analyzer does not work correctly and transmission session ends with an error Default value by default it is assumed that the time between successive characters is equal to 50 millis
5. NI 1 1 NOTHING start of tested gas measuring X207 PGB CHANI 1 1 NOTHING 1 4 Driver Configuration The S700 protocol driver may be configured by use of the section S700 placed in the application INI file Individual parameters are transferred in separate items of the section Each item has the following syntax item_name number number YES NO v LOG_FILE file_name Meaning the item allows to define a file to which all diagnostic messages of the S700 driver and information about contents of telegrams received by the driver are written If the item does not define the full path then the log file is created in the current directory The log file should be used only while the asix start up Default value by default the log file is not created ASKOM Gliwice August 2005 7 700 Driver of MAIHAK Analyzer Protocol asix4 lV LOG_OF_TELEGRAMS YES NO Meaning the item allows to write to the log file declared by use of LOG_FILE the contents of telegrams transferred within the communication with a S700 analyzer Writing the contents of telegrams to the log file should be used only while the asix start up Default value by default telegrams are not written v LOG_FILE_SIZE number Meaning the item allows to specify the log file size in MB Default value by default the item assumes that the log file has a size of 1 MB v IGNORE_STATUS_CHARACTER YESINO Meaning in each answer from S700
6. X92 NSPW3 2 CHANI 1 1 NOTHING _FP X93 NSPW3 3 CHANI 1 1 NOTHING _FP X94 NSPW3 4 CHANI 1 1 NOTHING _FP X95 NSPW3 5 CHANI 1 1 NOTHING_FP s X101 NSPW4 1 CHANI1 1 1 NOTHING_FP X102 NSPW4 2 CHAN1 1 1 NOTHING FP X103 NSPW4 3 CHANI1 1 1 NOTHING FP 6 August 2005 ASKOM Gliwice asix4 S700 Driver of MAIHAK Analyzer Protocol X104 NSPW4 4 CHANI1 1 1 NOTHING_FP X105 NSPW4 5 CHANI1 1 1 NOTHING FP X111 NSPW5 1 CHAN 1 1 NOTHING FP X112 NSPW5 2 CHANI1 1 1 NOTHING _ FP X113 NSPW5 3 CHAN1 1 1 NOTHING FP X114 NSPW5 4 CHAN1 1 1 NOTHING FP X115 NSPW5 5 CHAN 1 1 NOTHING FP X121 NSPW6 1 CHAN 1 1 NOTHING FP X122 NSPW6 2 CHANI1 1 1 NOTHING FP X123 NSPW6 3 CHANI1 1 1 NOTHING FP X124 NSPW6 4 CHANI1 1 1 NOTHING FP X125 NSPW6 5 CHANI1 1 1 NOTHING FP settings of calibration tray SPKK pump NSKK rated X130 SPKK CHANI 1 1 NOTHING X131 NSKK1 CHANI 1 1 NOTHING _FP X132 NSKK2 CHANI 1 1 NOTHING _FP X133 NSKK3 CHANI 1 1 NOTHING _FP X134 NSKK4 CHANI 1 1 NOTHING _FP X135 NSKK5 CHANI 1 1 NOTHING _FP start of zero calibration gas 1 and 2 X201 PGKZ1 CHANI 1 1 NOTHING X202 PGKZ2 CHANI 1 1 NOTHING start of standard calibration gas measuring 3 6 X203 PGKW3 CHANI 1 1 NOTHING X204 PGKW4 CHANI 1 1 NOTHING X205 PGKWS5 CHANI 1 1 NOTHING X206 PGKW6 CHA
7. asix4 User s Manual see and get more S700 Driver of MAIHAK Analyzer Protocol User s Manual Doc No ENP4049 Version 29 08 2005 User s Manual asix4 ASKOM and asix are registered trademarks of ASKOM Sp ka z 0 0 Gliwice Other brand names trademarks and registered trademarks are the property of their respective holders All rights reserved including the right of reproduction in whole or in part in any form No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or by any information storage and retrieval system without prior written permission from the ASKOM ASKOM sp z o o shall not be liable for any damages arising out of the use of information included in the publication content Copyright 2005 ASKOM Sp z o o Gliwice ASKOM Sp z o o ul J zefa Sowi skiego 13 44 121 Gliwice AS zsa tel 48 0 32 3018100 fax 48 0 32 3018101 http www askom com pl e mail office askom com pl asix4 S700 Driver of MAIHAK Analyzer Protocol 1 700 Driver of MAIHAK Analyzer Protocol 1 1 Driver Use The S700 driver is used for data exchange between Maihak S700 gas analyzers and an asix system computer by use of the AK protocol The communication is performed via standard serial ports of an asix computer and the serial interface no 1 of the analyzer NOTE Settings Serial in
8. econd Parameter 8 August 2005 ASKOM Gliwice asix4 700 Driver of MAIHAK Analyzer Protocol station_no number AK ID of analyzer number time in milliseconds from 10 to 300 ASKOM Gliwice August 2005 700 Driver of MAIHAK Analyzer Protocol asix4 10 August 2005 ASKOM Gliwice asix4 Table of Contents 1 S700 DRIVER OF MAIHAK ANALYZER PROTOCOL 1 1 DRIVER USE 12 DECLARATION OF TRANSMISSION CHANNEL 1 3 ADDRESSING THE PROCESS VARIABLES 1 4 DRIVER CONFIGURATION NBR WW Ww ASKOM Gliwice August 2005 11
9. terface lof the analyzer must have the following values without RTS CTS protocol without XON XOFF protocol Settings Communication 1 of the analyzer must have the following values ON 1 1 2 Declaration of Transmission Channel The full syntax of declaration of transmission channel operating according to the S700 protocol is given below logical_channel_name S700 id port baud character parity stop where S700 driver name id analyzer identifier number AK ID port port name COM1 COM2 etc optional parameters baud transmission speed character number of bits in a character parity parity check type stop number of stop bits If optional parameters are not given then default values are as follows e transmission speed of 9600 baud e 8 bits in a character e no parity check NONE e number of stop bits 1 EXAMPLE The declaration of the logical channel named CHAN1 operating according to the S700 protocol and exchanging data with the analyzer no 1 via the COM2 port is is follows CHAN1 700 1 COM2 The S700 driver is loaded as a DLL automatically ASKOM Gliwice August 2005 3 700 Driver of MAIHAK Analyzer Protocol asix4 1 3 Addressing the Process Variables The syntax of symbolic address which is used for variables belonging to the S700 driver channel is as follows lt type gt lt index gt lt element gt where type variable type index
10. ubstance in standard calibration gas FLOAT NSPZ rated value of measured substance in zero calibration gas FLOAT Types only for reading DWK sensibility drift after calibration DZK zero point drift of calibration substance after calibration MNU menu language identifier NRS analyzer serial number NSKK rated value of measure substance in calibration tray SPKK status of a calibration tray pump SPT name of measured substance SPW current values of measured substance SPZ limit range value of measured substance STA current analyzer status 4 August 2005 ASKOM Gliwice asix4 700 Driver of MAIHAK Analyzer Protocol Types only for writing PGB measuring introducing of tested gas in the analyzer PGKW measuring introducing of standard calibration gas to the analyzer PGKZ measuring introducing of zero calibration gas to the analyzer Types for reading and writing CZO delay time CZK time of calibration measurement IDA identifier of the analyzer NSPW rated value of the measured substance in zero calibration gas NSPZ rated value of measured substance in zero calibration gas SKT compensation of measured substance temperature SPKW status of a standard calibration gas pump SPKZ status of a zero calibration gas pump EXAMPLE Examplary declarations of variables names of types SPT and ranges SPZ of measured substances with an index
Download Pdf Manuals
Related Search
Related Contents
Samsung SP-D300B Digital Radiation Monitor - Vernier Software & Technology Samsung Samsung E1270 User Manual phone manual sks58800x0 nl koelkast gebruiksaanwijzing 2 en refrigerator user User`s Manual GTUM-001 SUPERPIDPID USA.qxd - Integrated Medical Systems, Inc. Sears 390.303302 User's Manual COEF MP700 Zoom Copyright © All rights reserved.