Home
JCIMA-P2 User Manual - Jointcom Communications
Contents
1. System will be turned off in 30s If not response from PIM Analyzer the screen will then show F1 3 Hold between 3s to 6s force to turn off after 30 seconds System will start counting show in the LED screen from 30 to 0 and then forced to be turned off after 30 seconds 4 Hold more than 6s force to turn off instantly System will turn off right away Start Button After turning on the PIM Analyzer when press START button system starts the measurement If press start button again the measurement will be stopped User Manual Rev 1 02 21 JCIMA P2 Multi function PIM Analyzer 2 3 2 Function Status LEDs As shown in Figure 2 1 there are 4 function status LEDs which are WiFi PIM VSWR and ISO LEDs in JCIMA P2 front panel Table 2 1shows the detail status of functional Status LEDs LED Status Notes WIFI LED ON WiFi is turned on and working properly WIFI LED Off Problem with WiFi PIM LED ON JCIMA P2 is under PIM Measurement function VSWR LED ON JCIMA P2 is under VSWR Return Loss Measurement function ISO LED ON JCIMA P2 is under Isolation and Insertion Loss Measurement function PIM VSWR and ISO LED Off JCIMA P2 is under RTF Spectrum Analyzer or 2 Harmonic measurement function Table 2 1 Function Status LEDs 2 3 3 Table of LED Screen Status Display Turn on the PIM Analyzer an cyclically System boot u
2. e Press the Close button to exit the dialog Jointcom User Manual Rev 1 02 101 JCIMA P2 Multi function PIM Analyzer Appendix A Product Specifications Dimension amp Weight PIM Measurement Spectrum Measurement Jointcom Swept PIM PIM vs Time Range to Fault Spectrum Swept VSWR Swept Isolation Swept 2 Harmonics AC DC Adapter Power Consumption Dimension Weight RF Test Power Residual PIM Performance PIM Measurement Range Frequency Range Noise Floor RBW Dynamic Range Attenuation Amplitude precision Frequency Precision d th sth th 3 5 7 and 9 order reverse intermodulation product when in receive band user selectable d th sth th 3 5 7 and 9 order reverse intermodulation product when in receive band user selectable Distance and relative magnitude of PIM source Broadband Spectrum Measurement 100MHz 3GHz VSWR or Return Loss Measurement for the transmission band user selectable Isolation or Insertion Loss Measurement for the transmission band user selectable d CE 2 Harmonics Measurement for the transmission band user selectable Input 110VAC 220VAC 50 60 Hz Output 48VDC 300W 408mm x 235mm x 140mm 10 12Kg Two CW tones 10 dBm to 43 dBm 0 1 dBm steps lt 122 dBm lt 125 dBm typical 2x 43 dBm lt 135 dBm 2x35dBm 65 dBm to 135 dBm 100MHz 3GHz 135dBm 1KHz Receiving Band
3. User Manual Rev 1 02 46 JCIMA P2 Multi function PIM Analyzer 4 2 4 Setup for Distance Range Press SET DISTANCE softkey in Command Bar The Set Distance window will pop up for setting the distance range which user wants to measure Set Distance Distance 0 00 50 00 Onessom OK cancel Figure 4 6 Set Distance Setup Window 4 2 5 Calibration at O Meter 4 2 5 1 Calibration at O meter under RTF Test Mode When under RTF test mode press the O METER CAL softkey in Command Bar The following window will pop up Input the value of the Standard Adapter used by Calibration Please Enter The Standard alue Standard Value 80 dBm OK Cancel Figure 4 7 0 Meter Calibration Setup Window for RTF Test Mode After pressing OK button the Calibration process will be started and the pop up window will be closed automatically Please refer Chapter 4 3 2 for detail process of Calibration 4 2 5 2 Calibration at O meter under VSWR Test Mode When under VSWR test mode press the 0 METER CAL softkey in Command Bar Stay with the default value unless there is specific instruction from manufacture document Please Enter The Standard alue Standard Value 20 dBm OK Cancel Figure 4 8 0 Meter Calibration Setup Window for VSWR Test Mode After pressing OK button the Calibration process will be started and the pop up window will be closed automatically Please refer Ch
4. TRACE SELECT softkey in Command Bar to select to enable or disable the trace e Press the trace number user wants to enable OPT 1 ON TRAE PEFLESH MAXHOLD MINHOLD HOLD ee 55 OFFSET BACK NEXT SELECT TRACEL TRACES TRACES TRACES TRACES lt gt To refresh a trace press the REFRESH button Jointcom User Manual Rev 1 02 66 JCIMA P2 Multi function PIM Analyzer lt Display the current measurement and MAXHOLD level of the measurement e The MAXHOLD softkey updates the maximum measured level This allows you to make a comparison between the maximum and the current levels Center 00 000MHz fy TUA y A MOA A 1 0 Grrr 1c U iv TRACE SELECT REFRESH MAXHOLD MINHOLD HOLD y WW AnA aN A Ad i Wz MAXHOLD level j N Afm Var ral f AA TAT 4 M N A W Y y s Y Ti ka V Vy W i Span 0 150MHz OFFSET OPTION SACR NEXT lt Display the current measurement and MINHOLD level of the measurement e The MINHOLD softkey retains the minimum measured level This allows you to make a comparison between the minimum and the current levels Center 900 000MHz TRACE REFRESH MAXHOLD MINHOL SELECT Jointcom User Manual Rev 1 02 urement Current meas fy W r NY ih NG Span 0 150MHz MINHOLD levle E FFSET D HOLD r A y OPTION BACK NEXT 67 JCIMA P2 Multi function PIM Analyzer lt Display the current measu
5. User Manual Rev 1 02 48 JCIMA P2 Multi function PIM Analyzer F Prop fo 710000 D E 105 0 E 4 2 6 3 PIM Fault Threshold Setup In Limit option as shown in below user can set the PIM fault threshold for the measurement 4 2 6 4 Cable Loss Setup To make the distance measurement more accurate user needs to input the cable loss dB 100 meters in Cable Loss option Jointcom JOIN TOOM COMMUNC ATION TECHNOLOGY COLTO User Manual Rev 1 02 49 JCIMA P2 Multi function PIM Analyzer 4 3 Distance to PIM Fault Measurement 4 3 1 Preparation before Measurement 4 3 1 1 Preparation for distance to PIM Measurement e Connect the PIM Analyzer to system under test and then to 50W Low PIM Termination via Low PIM test cable as shown in Figure 4 10 i N Low PIM Test Cable System Under Test 50W Low PIM Termination Figure 4 10 Setup for Distance to PIM Please use the torque wrench to ensure the accuracy of measurement results Recommended torque 5N M for N type connector 17 5 22N M for 7 16 type connector 4 3 1 2 Preparation for distance to VSWR Measurement e Connect the PIM Analyzer to system under test and then to 50W Low PIM Termination via Low PIM test cable as shown in Figure 4 11 INPUT Port Low PIM Test Cable System Under Test 50W Low PIM Termination E CI a Coupling Port Figure 4 11 Setup for Distance t
6. cccscccccesseccceeseccceescceceesecseeeeeeeeees 47 Figure 4 8 O Meter Calibration Setup Window for VSWR Test MOd cccccccsseeccceeseccceeecceeeeseceseeeeeeeees 47 Figure 4 9 Velocity Factor Calibration Setup WINKOW esssesssesesressssresesrcrsssresssrresssreresrterssrersrterserereeerereseeeee 48 Figure 4 10 Setup for Distance to PIM cessccnccssasenccutecuassaceneaundcucasacensaas E E E 50 Figure 4 11 Setup for Distance to VSWR eseesesssseesssscesesrcressreresrtrsssreresrtrsssrtrsrterseetresrteessrtreseterseeteeesteeeseeeee 50 Figure 4 12 O Meter Calibration Setup for distance to PIM eesseesesesesreressresesrrrsssreresrrerssreresrersesrereerrereseeees 51 Figure 4 13 O Meter Calibration Setup for distance to VONN eer eee 52 J intcom VII JCIMA P2 Multi function PIM Analyzer Figure 4 8 Velocity Factor Calibration Setup 00 0 0 ccccccccesecccceseccccesececeesececceeeceeeuecesseeceeseeeecesseecesseeesseees 54 Figure 5 1 Spectrum Analyzer Operation INterface ccccccccescccccesscccceseccccesecsceusececuueecssseeeceseeeceesueeseeees 58 Figure 5 2 Spectrum Test Curve S ction cccccccscccscceseceseccsecesscesecesecceceeceeeceeeceeeceesssenseeeseenceeceeeeeeeenesea 59 Figure 5 3 Spectrum Command Bal seiiesscecetisri inen EA ETE AO 60 Figure 5 4 Setup for Spectrum Measurement eessssessesresesrrrsssreresrtrrssrtrssrtressrtessrtrssereresetresetereseteeserereseeres 71 Figure 6 1 Operation Interface of Isola
7. Connect the remote control terminal can be PC Tablet or Smart Phone to JCIMA P2 Detail setup is described at Chapter 2 2 An external display can be directly connected to the PIM Analyzer via the VGA port of JCIMA P2 Please be noted that the JCIMA P2 needs to be rebooted while external display is connected And only one display either remote or local display can be supported at a time 6 When the software starts up the system will get to Windows interface first and then starts the hardware self check process for PIM Analyzer application automatically On the Windows interface double press fl PIM icon can also start the test softw are The left figure shows the self check window If the system passes hardware self check all items will show succeeded If hardware self check shows failed for any item the PIM Analyzer needs to be rebooted If the problem persists please contact manufacturer o gt Start Test Please refer Chapter 3 for details 99 After the measurement the test results can be copied to USB flash stick or external hard driver via USB 2 0 port The default access path is D Reports As the C driver is set as write protection please do not store any test report in C driver or desktop gt e Jointcom User Manual Rev 1 02 V RRA IAT Wih JCIMA P2 Multi function PIM Analyzer 9 Press the Power o button t
8. 2 Harmonic and 2 order PIM Measurement FUNCTION cccseeeeeeeee 90 Figure 8 2 2 Harmonic 2 Order PIM Measurement Test Curve Section cccccccscsssesesesescececesessseseseseeeeess 91 Figure 8 3 2 Harmonic 2 PimTest Result Evaluation Section cccccccccccsecescsesesesesesesesesesesescscscecceseseseeeeess 92 Table List Table Bad JCOIMA P2 Models spresnenia nara eiai l Table 2 1 Function Status LEDS sssrisiosiecirmi ona E T E A E E 22 Table 3 1 Valid Frequency Range lt aaee ene ee re nS ee ee ee ee ee en eevee 31 Table 4 1 TX Frequency and 3 Order PIM Frequency Range for RTF c ccccccceeecceeeccceeecsceeesseesecseenssseeeeees 46 Table 5 1 Frequency Ranges for Narrowband Mode cccccccecccceseccceeccceeccceeccceecseeescseesessuecsseeceuseeseususs 62 Table 6 1 Valid Frequency Range for Isolation Insertion Loss Measurement cccccccccceeeeeeeeeccccseeeeeeeeeeees 76 Table 7 1 Valid Frequency Range for VSWR Return Loss MeaSureMe nt eeeeccccccccceeeeeesseccccseseeeeeeeeees 84 Table 8 1 Valid Frequency Range aeeee nen nt ne el ne nen ee ven ee ere ee eee eee ee 95 Jointcom VIII JCIMA P2 Multi function PIM Analyzer 1 Overview JCIMA P2 Multi function PIM Analyzer is an integrated source and receiver that generates high power signals to measure the reflected 3 order 5 order or 7 order and 9 order Passive Intermodulation PIM products via its spectrum analyzer In addit
9. 869 0MHz 894 0MHz Power 43 0 10 0dBm 43 0dBm Freq Step 1 0 MHz PIM Order IM3 Att 0 0 dB Count Default OK Figure 3 7 Setting Window for PIM Setup J intcom User Manual Rev 1 02 28 JCIMA P2 Multi function PIM Analyzer 3 2 1 Test Mode Setup There are 3 test modes Frequency Sweep Time Sweep and Power Sweep Setting SweepType Freq_Sweep F Frequenc Power Sweep 3 2 1 1 Frequency Sweep Mode When under Frequency Sweep mode the PIM Analyzer will sweep 2 RF carriers with defined frequency range and power level and measure the PIM performance 3 2 1 2 Time Sweep Mode When under Time Sweep mode the PIM Analyzer will generate user defined RF carriers and perform the PIM measurement by time 3 2 1 3 Power Sweep Mode When under Power Sweep mode the PIM Analyzer will generate user defined RF carriers with sweeping power range and step and perform the PIM measurement 3 2 1 4 Setup Test Mode In Sweep Type option of Setting Window when choosing Freq_Sweep the PIM measurement is Frequency Sweep Mode sweep Type Freq_Sweep When choosing Time_Sweep the PIM measurement is set to be Time Sweep Mode J intcom User Manual Rev 1 02 29 JCIMA P2 Multi function PIM Analyzer 3 2 2 Sweep Times Setup In Sweep Times setup of the Setting Window user can define the sweep times More sweep times is chosen more accurate the PIM measure wi
10. And the START and PEAK buttons will be turn green SETTING When pressing START button again the PIM measurement will stop The START and PEAK buttons will turn back to gray When system is under PIM Measurement function user can also start and stop the PIM measurement from pressing the START button in the front panel of PIM Analyzer first push to start pressing again to stop The JCIMA P2 has self protection feature to prevent the high power output without proper termination For PIM measurement with either GUI or front panel control when output RF signals are not properly terminated the system will automatically detect the problem turn off the PA and pop up the following alert windows on the test screen Jointcom User Manual Rev 1 02 37 JCIMA P2 Multi function PIM Analyzer PIM RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2012 10 20 7 4228 Pass Fail limit dBm RF1 swr W RF IS CLOSED 80 F2 swr W om 3 RF IS CLOSED x IM5 TM7 TM9 dBm dBc Im3_V dBm SETTING 3 3 3 Calibration for PIM Measurement 3 3 3 1 Residual Intermodulation To make sure the PIM Analyzer works properly the residual intermodulation measurement needs to be performed after the PIM Analyzer is turned on e Use the setup shown in Figure 3 12 e Run PIM measurement 3 times to warm up the PIM Analyzer e Re run PIM measurement 3 times Confirm all 3 test results are constant
11. EEE E EAEE E A A EI E E E 27 I7 0 6 2 610 010 EO er E E E E EE E E AA E 27 3 2 SETUP FOR PIM MEASUREMENT nssesesesesesessssssssesenenerrnrorerererereseseseseseseseseseneseseseororererorerereseseseseseseseseeenene 28 3 2 1 FESS E8 E E T 0 ae EEE EEA AA A EE EA E eee 29 3 2 1 1 Freguency SWEEP MOCE ssccccccsssecceceesececcuesececeaeeeceseasseeeeaeeeeeeesaeseceessasecesseaseceesueseceesauaeceesseascessauascessauaeeeesaganess 29 3 2 1 2 TU UMTS GNU SSO IVS gases ace seis gates sciatic cates ea ae sd sacs es cde cee 29 3 2 1 3 PRE O OS O AN E A E ETE E E E AT oe E A A A A E 29 3 2 1 4 PIE CNO r E T T Reenter re cera eee re 29 S22 SWED TINE SCUD sis icansvancossarnesdonaianaennsetnwicnsetasevasanmsitonatpeuaasauneiecsetavsadsaraniiese tatiadsatensccsateseccsa vers 30 3 2 3 RE COMICTS Parameter Sel UDrisinerreiricipririereoruri yenen n EE EEEE E ER 30 3 2 3 1 Fr TCL M SS t PE E E EE A E E E E E A A A 30 3 2 3 2 POWO SS UD T E T T N T ENR 32 J intcom JCIMA P2 Multi function PIM Analyzer 3 2 3 3 FRCCMENEY SUC Se U Derr een enana Ea douuasuaceatenabucedactamnecaw TEE T Poquecetnoouedentueeeds 32 324 SetUD JO PV OrAETS orirerpr nenets Enine nen E E EEEE EE EREDETE EEEREN 32 325 ANUJU OnN 56 0 ss arcsatesaosastacnnvedinancaaanwspuctsissinaanisennoedioensaeinoniudsiannesadianivenitvanewanesivisaiaaonagenen 33 3 2 6 COUN SCD iiacasdeotacuie E E T 33 3 2 7 Power Range and Power Step SCtup sssccsesecccesecccesecccesecccesece
12. Manual Rev 1 02 20 JCIMA P2 Multi function PIM Analyzer 2 3 1 Turn On Off PIM Analyzer and Run the measurement At the right side of front panel display there are START and Power buttons Power button is for turning on off PIM Analyzer Start button is for start or stop measurements 2 3 1 1 2 3 1 2 Jointcom Power Button After pressing the power button the system starts to boot up and the LED screen in the Status and un Test Result area middle of the display will display moving cyclically When boot up successfully completes the LED screen will show 000 0 If boot up fails or system has no response more than 70 seconds the LED display will show FO While the PIM Analyzer is on press and hold the power button the display screen will show xx and PIM Analyzer will start the turn off process xx is 2 digit number which shows the time E g 0 5 means 0 5 second 1 0 means 1 second The normal turn off procedure is to press and hold the power button between 1 to 3 second But user can also force system shutdown with holding the power button more than 3 seconds when software can t turn off by itself Following is the system response while holding the power button with different time 1 Hold Power button less than 1 second System will treat this action as misoperation and won t response for the action 2 Hold between 1 to 3 seconds normal turn off process
13. Rev 1 02 64 JCIMA P2 Multi function PIM Analyzer 5 2 6 Enable Markers Press the MARKER SELECT softkey in the Command Bar to select markers on or off ALL OFF MARKER 1 MARKERS MARKERS MARKER 4 MARKERS MARKER SELECT 5 2 7 Setup Frequency for Markers Press the ENTRY softkey in the Command Bar and set the frequency of the marker OK Cancel MHz 5 2 8 Move the marker to Peak Power Press the Peak button in the Command Bar to move the marker to peak power point REF MARKER POSITION SELECT HOLD SCALE MENU BACK NEXT ENTRY PEAK REV 5 2 9 Setup for External Attenuation Compensation Press the REV softkey in the Command Bar and then input the external attenuation or insertion loss of the Device or System Under Test for compensation o dB Cancel J intcom User Manual Rev 1 02 65 JCIMA P2 Multi function PIM Analyzer 5 2 10 Hold MENU Press the HOLD MENU softkey in the Command Bar to select Maximum Hold or Minimum hold for Selected Markers MASAOLD MINAOLO 5 2 11 The Trace Function The trace function is used to retain and display the measurement result for a given point in time It is convenient for making a comparison with the current measurement data The spectrum analyzer provides the REFRESH MAXHOLD MINHOLD and HOLD commands which can be selected while a trace is being displayed lt Activate the trace function e Press the
14. Setting Window for PIM Setup ccc ceccccccessecccceecccceeseccceueceeceecceseusecesseeecsesueeeceseusecesseeeeseees 28 Figure 3 8 RE CAL els Setup Se CO sect uate cette eres cg cere nacre ec ce canes ates ETEO 30 BOs ee Bey ald elm Ce PIM Ode giana ar nner oO ns So eo oe nee eee 33 Fieure o OC OU ODON cererea cass cts eats AEE oes cbasanabaaieceso Ea 34 Figure 3 Ir COUNE QOUOM scdascicaccsnnstundensinicdasnalacQniieeatensvaiiesdacnaceidobestiedestemedaannaiacdonsancadobntliidontaescassmuiiudactonescabad 34 PS 3 12 SOU TOU PIM TES eee EE E EEE EA 36 Figure 3 13 Calibration Setup for Standard Adapter seessesessseessseneseesssesssessssesssresseessersseeesserseersseresserseerese 39 Figure Aa 1 RIF Operation lnter dOE serten er EE EE O EN 42 Feu re 4 2 RIFPIM Test CURVE SECU OM essnee ANE 43 Figure 4 3 RTF VSWR Test Curve SOCTION sicdidecsscnssdess Svadecesacndsnsaddbeeesbounddusisvacevshcewidenssdadaossasxisectesadaus vavadewsaddudas 44 Foure aAA RTF C OMMON Bit ccpeacs ssescazcatccacsesaessascnassnacesegacataszcsancosaenccaasacseasossgsanne masnasemsessacasaconasacneseosasseseacerse 44 Figure 4 5 O Test Mode Setup for RTF Function seeessssessesessresesrcrsssreresrtrrssreresetesseeeresrterssrersrtersereeeerteeeseeeee 45 Figure 4 6 Set Distance Setup Window eesseeeseseeeseesesersserssrrrssrrssressetesstessrersetesstessecrsetesstesseeesetesseerseeeseee 47 Figure 4 7 O Meter Calibration Setup Window for RTF Test MOde
15. Test Result After PIM Measurement the PIM test result will show as curve and report table as described in Chapter 3 1 2 and Chapter 3 1 6 In the test curve section the Peak PIM will be marked with A after each PIM measurement The test result curve can be zoomed in by pressing the a sign at the right top side of the Test Curve Section and then zoomed out by pressing e at the same location Peak PIM Value 100 0 Zoom In U 0 140 0 180 0 180 0 Ga Peak Marker Jointcom User Manual Rev 1 02 39 JCIMA P2 Multi function PIM Analyzer The peak PIM measurement result is also shown in the LED screen of PIM Analyzer front panel 3 3 5 Save and Read PIM Test Result 3 3 5 1 Save the PIM Test Result e Press the SAVE softkey in Command Bar SETTING e The save setup window will pop up PimSaveForm Save Path d reportipim Change Menu File Type File Name CSV 2009 01 02 19 24 08 JPG 2009 01 02 19 24 08 PDF 2009 01 02 19 24 08 modno here is no model no OK serno here is no serial no opeor default user Cancel e Choose the file format can be multiple logs with different formats e Specify the file name model number modno serial number serno and the tester s name opeor e Press OK button to implement Save command The test result will be saved under D Report pim w
16. Test via test cable as shown in Figure 5 4 Narrowband DIN Connector System Under Test Cable Test eee N Type Connector Figure 5 4 Setup for Spectrum Measurement Connect to DIN Connector when user wants to implement narrow band scan O Connect to N Type Connector when user wants to implement broad band scan Caution The maximum input power on for both AUX and RF IN OUT ports must be less than 10dBm Please use the torque wrench to ensure the accuracy of measurement results Recommended torque 5N M for N type connector 17 5 22N M for 7 16 type connector e When using remote control terminal please confirm only WiFi LED in PIM Analyzer front panel is on Red and the LED screen shows 1111 5 2 17 Start and Stop the Spectrum Measurement In JCIMA P2 test interface press the SPECTRUM softkey in Functional Option Section Press the ANALYZE button in Command Bar to start the spectrum measurement The ANALYZE button will turn to green when running test lt Press the ANALYZE button in Command Bar again to stop the spectrum measurement The ANALYZE button will return to normal when spectrum measurement stops d ANALYZE ATT START STOP CENTER SPAN RBW LAST NEXT Jointcom User Manual Rev 1 02 71 JCIMA P2 Multi function PIM Analyzer 5 2 18 Save and Read the Test Result 5 3 3 1 Save the Spectrum Measurement e Press the SAVE softkey in Command
17. The VSWR warning threshold for PA The default value is 2 0 lt gt Temp Limit The temperature warning threshold for PA The default value is 60 0 C lt Narrowband Narrow Band mode for Spectrum Measurement lt gt Broadband Broad Band mode for Spectrum Measurement lt gt Test Mode For Manufacture test only lt gt File Manage For test result file management e Press OK button to save and close the Global Configuration Window 9 2 Screen Lock Function Press the LOCK softkey in Function Option Section The System Lock window will pop up for lock screen setup Jointcom User Manual Rev 1 02 100 JCIMA P2 Multi function PIM Analyzer Lock psd Please entry your password Reset e Input the password and then press the Lock softkey The test interface will be then under lock state No softkey will work under this state e To deactivate the lock state input the password again then press OK button returns to the normal Pim SPECTRUM TSOLATION VSWR HARMONTC CONFIG COCK QUIT Please entry your password START PAUSE PEAK NEXTPEAK DATASAVE DATAREAD SETTING e To modify the password select Reset option input the original password in Old psd the new password in New psd repeat the new password in Again psd and then press OK button Lock psd Please entry your password Reset password Qed M New ped eee Again psd eae Reset
18. The residual intermodulation should be less than 122dBm or 165dBc 43dBm lt 2 Typical 168dBc Due to the natural wearing down for 7 16 connector the residual intermodulation will eventually get worse Therefore the 7 16 Male to Female adapter is suggested to be used to protect the RF Out port And when the residual intermodulation is worse than 165 dBc the 7 16 Male to Female adapter is suggested to be replaced 3 3 3 2 Calibration for Standard Adapter The Standard Adapter provided by manufacture has very stable PIM performance It s used to calibrate the PIM measurement accuracy of the PIM Analyzer There are 2 types of Standard Adapters one with 80dBm PIM3 2 43dBm and another with 110dBm PIM3 2 43dBm which has stable 80dBm and 110dBm 3 order passive intermodulation performance e Connect the RF Out Port of PIM Analyzer to Standard Adapter and then Low PIM Termination via Low PIM test cable as shown in Figure 3 13 e Run PIM measurement 3 times to warming up the PIM Analyzer Jointcom User Manual Rev 1 02 38 JCIMA P2 Multi function PIM Analyzer e Re run PIM measurement 3 times Confirm all 3 test results are constant Low PIM Test Cable a Figure 3 13 Calibration Setup for Standard Adapter 50W Low PIM Termination A N The PIM result should be less than 3dB of the PIM3 value marked in the Standard Adapter If the error is more than 3dB please contact the manufacture 3 3 4 PIM
19. Wide is broadband which is from 100MHz to 3GHz 5 1 3 Command Bar Spectrum Analyzer Command Bar is for spectrum parameter setup measure and test result saving or reading e Press NEXT button to show the next page of Command Bar Jointcom User Manual Rev 1 02 59 o ooo ooo ooo ooo ooo ooo eso JCIMA P2 Multi function PIM Analyzer e Press BACK button in the extended Command Bar to move back to former page of Command Bar ANALYZE SCALE TRACE SELECT SAVE ANALYZE ATT START STOP CENTER SPAN RBW LAST NEXT SCALE REF POSITION MARKER SELECT ENTRY PEAK REV HOLD MENU BACK TRACE SELECT REFRESH MAXHOLD MINHOLD HOLD lt lt gt gt Jointcom REF POSITION REFRESH MAXHOLD MINHOLD HOLD gt READ START STOP CENTER SPAN RBW LAST NEXT MARKER SELECT HOLD ENTRY MENU PEAK REV BACK NEXT OFFSET OPTION PAOR NEXT CHANNEL SCANTIMES POWER TOP Figure 5 3 Spectrum Command Bar Start or Stop Spectrum Measurement Setup for Internal Attenuation Start frequency Stop frequency Center frequency Frequency span setup Resolution bandwidth setup Move to last page of Command Bar Move to next page of Command Bar Setup the dB value per DIV for Y Axis Setup numbers of DIVs for X Axis and Y Axis Enable Markers marking in Test Curve Section Setup the frequency of enabled Marker Move or create the marker to peak power po
20. ee E TE E EE E EEE R 81 7 1 2 TOSE CUS SCC Oi eea E E A E As 82 7 1 3 COMTO BO na N EAA A A A 83 7 2 SETUP FOR VSWR RETURN LOSS MEASUREMENT sseccccessscccessececcessceceesceceeusececeuececsenececceseeesausesecauneess 83 7 2 1 Frequency Range Setup vciiissvrasisnuvcactuwusausstecdasaveoniadeodusdsieccaustoncddessecaddnsienkiuveddesoencdasheceniseabiastaueede 83 T VAIS AUTO RegldO Nessie iE aA EN AEE EAEE EEEE 84 7 2 3 VSWR Return Loss Setting WinNdOW sssssseeeeeseesesssrrrrrrrrrrrrrresessssssssrrrrrrrrrrrreeessssssssrrererrrrreeeee 85 7 2 4 Switch between Return Loss and VSWR ccccesccssccscccscccscccsccssccesscssssesssecssessseussessessessenscensces 86 7 3 VSWR RETURN L SS MEASUREMENT cesacecscescceccsusatecasnidinassoceteecunssssensnsadvsdeemiisandentaGesabndaieacousatecsosideauasses 86 7 3 1 Calibration before MCASULCIMENL ccccsesecccseesececsesecccseesesecesecetsusecessusessseusecsssueeesssesesesseseeeeas 86 7 3 2 Start and Stop the VSWR Return LOSS MCQSUEMENL ccccccccccccseeseccccecccsssseeeeececssssssueeeeeeeeeess 87 Dy ae ae eset sce E ma een ete naar cc A tae dae sc ee ac pease tao eee eet eae etna anenaet tu ees 87 7 3 2 2 Start and Stop the measurement sssessssseessssrressrrresssrrrsssrersssrersssrrressreresereressreressreressreressrtresserressseeessrreressereesseeeent 88 7 3 3 Save and Read the Test Result visiccweresicocercdascvesssisosenidia dorcudtacesc ssadueresiveescodsadbenesteceeabbioiennsoonoee
21. exe SYSTEM oo 4 468 K svchost exe LOCAL SERVICE 00 4 620 K svchost exe NETWORK SERVICE 00 3 048 K svchost exe SYSTEM 00 14 532 K svchost exe NETWORK SERVICE 00 4 300 K svchost exe SYSTEM 00 5 392 K lsass exe SYSTEM oo 980 K services exe SYSTEM oo 4 928 K winlogon exe SYSTEM oo 4 760 K csrss exe SYSTEM 00 4 000 K 4 ee smss exe SYSTEM o0 396 K Pass Fail limit dBm tIntsvr exe SYSTEM 00 4 020 K Ad 320 J Show processes from all users End Process 46 72 948 16 849 6 Q A7 r IMS IMS IM7 IMO dBm dBc NO P1 dBm F1 MHz P2 dBm F2 MHz Im3_F MHz Im3_ dBm MaxPIM 0 0 dBm MinPIM 0 0 dBm AvgPIM 0 0 dBm Power Temp YSWR SETTING Press Yes button in the pop up window to disconnect the remote desk iol x e opins ST Hep VSWR HARMONIC CONFIG LOCK QUIT 20131111151512 Applications Processes Performance Networking Users e4 Peak Windows Task Manager Image Name User Name CPU memusage inetinfo exe SYSTEM 7 996 K SYCHOST EXE Administrator 7 2 764 K ctfmon exe Administrator 00 3 620 K rdpclip exe Administrator 00 4 088 K spoolsv exe SYSTEM 00 5 244 K explorer exe Administrator o1 13 780 K taskmar exe Administrator 02 4 800 K a svchost exe SYSTEM 00 4 488 K sychost exe LOCAL SERVICE 00 4 620 K svchost exe NETWORK SERVICE 00 3 048 K svchost exe SYSTEM 00 14 556 K mspaint exe Administrator oo 2 200 K svchost exe NETWORK SERVICE 00 4 304 K svchost ex
22. protected by 60dB attenuation 2 x 30dB Attenuators and press OK button to close the warning window e Press SETTING softkey in Command Bar e Leave all options as default in the Setting Window e Press Start button to start calibration e Press OK button to close the Setting window Isolation ee Settings Tx 30 0 a dEm ATT lo dB Calibration in progress Calibration Carrier Start Calibration Default OK Cancel 6 3 2 Start and Stop the Isolation Insertion Loss Measurement 6 3 2 1 Test Setup Figure 6 5 and Figure 6 6 show the test setup for Isolation and Insertion Loss measurement respectively J intcom User Manual Rev 1 02 78 JCIMA P2 Multi function PIM Analyzer DIN Connector Input Port 1 E Device Under ri est Input Port 2 JN Type F Connector 2x30dB Attenuators Provided by manufacturer Figure 6 5 Setup for Isolation Measurement DIN aan Connector Input E Port Device Under Test Test Cables 2x30dB Attenuators Connector Provided by manufacturer Figure 6 6 Setup for Insertion Loss Measurement 6 3 2 2 Start and Stop the measurement e Press START button in the Command Bar to start the Isolation or Insertion Loss measurement When measurement starts both START and PEAK buttons will turn to green After measurement completes the START and PEAK buttons will turn back t
23. stvi skr s rn ErE VOSKE EENES NNER EENE 47 4 2 5 2 Calibration at O meter under VSWR Test Mode ccccccsseccceseccceececeececeececseececeuecetsueceteuecessuecetsuecetsuecetsuacetsgess 47 426 Calibration for Velocity FACTOF cccccccseesecccesececcsececceesececcsecsscseeseseesesecsusecstsuseeseseesecessuseeeeas 48 Lr TTNG O Oe E E E E E AAE 48 4 2 6 Setup for Y Axis RINEE sete ccanaosnecanacshaetwesiscdainecaneeancasstevwasaitteaneonsacumeasaeameessldanaosndeiseassadabadasiGanaohidadanacandeanadnti utedaweeunccbsienteee 48 ALG etp Or VW CIOCILY FIC OT e iire N E E E E REA 48 4 2 6 3 PIM Fault Threshold S tup ccccccssscccccsssececceessccecseseeceeeeeeccecseaeecesseaseceeseeecessuaeceesueneceesueeceeseeaseeesseneeeeseugseessaneeeeees 49 AGAC DIE LOSS SEUD ir A E AEEA 49 4 3 DISTANCE TO PIM FAULT MEASUREMENT xcccsscscessedeeceedencncesseanudaudneensensedenssadeeseeensadedeeaeeatniacsheuncansacvieateesed 50 4 3 1 Preparation before Measurement s sccccseeseccsnosesccncussscscusescsscuescencuessencusesesecuescescuessencusssessess 50 4 3 1 1 Preparation for distance to PIM Measurement cccssssccccssssccecseesccceseusececseusececsueeceesuueeeessuaecessauasceesaeaeeeesagasess 50 4 3 1 2 Preparation for distance to VSWR Measurement ssssessessressssreressreressreressreressreressrrressreressrerrsssereesseressseeeeseeene 50 4 3 2 Calibration for Distance to PIM Fault Measurement scccccseeececcesece
24. turn to green After measurement completes the START and PEAK buttons will turn back to normal e Wait until measurement complete or press START button again to stop the measurement READ SETTING While the remote display reports the VSWR Return Loss measurement result the Peak VSWR Return Loss result is also displayed in the LED screen of PIM Analyzer front panel 7 3 3 Save and Read the Test Result 7 3 3 1 Save the Test Result e Press the SAVE softkey in Command Bar e The save setup window will pop up Save Path d reportiysw Change Menu File Type r File Name Vv CSV 2013 11 08 01 59 12 V JPG 2013 11 08 01 59 12 F PDF 2013 11 08 01 59 12 modno here is no model no OK sero here is no serial no opeor default user Cancel e Choose the file format can be multiple logs with different formats e Specify the file name model number modno serial number serno and the tester s name opeor e Press OK button to execute Save command The test result will be saved under D Report vsw with date and time automatically when using default name e After the test result is saved successfully the follow window will pop up Press OK button to quit the window Jointcom User Manual Rev 1 02 88 JCIMA P2 Multi function PIM Analyzer Saving the C5 File successfully Saving the PDF file successfully Sa
25. 022048 500 01 220VAC 110VAC to 48VDC Maximum Output Power 450W Tablet PC Operation System Windows XP SP3 Windows 7 SP1 or Android 2 2 or above Hardware At least 1GHz CPU 256M RAM and500M Hard Driver support WiFi RF Short Circuit AFA259 1 NM 500 RF Cable CYN400 0 5 0 5Meter NM NM 50Q Regular Wrench J intcom WRENCH 32 DIN Wrench User Manual Rev 1 02 6 JCIMA P2 Multi function PIM Analyzer 2 Operation 2 1 Turn on and turn off the PIM Analyzer Operating Steps Figures Connect the AC power cord to 220V 110VAC to 48VDC adapter and then connect to DC power cord from 220V 110VAC to 48VDC adapter to PIM Analyzer Turn on the power switch at 220V 110VAC to 48VDC adapter The PIM Analyzer can be either directly O supplied by 48VDC or via the 220V 110VAC to 48VDC adapter supplied by manufacturer When connecting AC power cord the 3 pin power cord needs to be connected to a 3 pin grounded power outlet If power is supplied without grounding there will be risk of receiving a severe or fatal electric shock Press the button in the front panel system starts to boot up and the LED runs cyclically in LED Screen as shown in the left picture Waiting around 1 minute until the LED shows 000 0 which means the equipment is ready for PIM the measurement J intcom User Manual Rev 1 02 7 JCIMA P2 Multi function PIM Analyzer 5
26. 120dBm 1KHz Wide band 1KHz 10KHz 100KHz 70dB 0 10 20 30 40dB 1 dB 2ppm User Manual Rev 1 02 102 VSWR amp Isolation Measurement Jointcom Frequency Range Return Loss Error Resolution VGA Port USB2 0 48VDC IN Port N Type AUX Port RF IN OUT Port JCIMA P2 Multi function PIM Analyzer By selected transmission band 0 5 dB RL 0 18dB 1 5 dB RL 19 25dB 0 1dB For external display with wired connection For external keyboard mouse USB flash drives etc For DC Power supply RF Input port N type RF port 50Q Impedance 10dBm maximum power handling 7 16 type RF IN Out port for maximum 2x 10dBm to 43dBm RF output 500 Impedance User Manual Rev 1 02 103 JCIMA P2 Multi function PIM Analyzer Appendix B Maintenance and tips To avoid RF ports being oxygenated in the air all RF ports on JCIMA P2 should be covered with special caps provided by manufacture when they are not used All RF connectors shall be cleaned with a lint free swab and alcohol before they are used Avoid touching the inner connectors directly body grease will accelerate tarnishing of the surface of the connector To avoid damaging the RF cable don t distort the test cable over its minimum bending radius especially for the joint part between cable and connector When screwing the RF connectors using the torque wrench provided by manufacturer Recommended torque 5N M for N type connector 17
27. 2 are set at sides of the unit The equipment turn on switch and status monitoring LEDs are set on the front panel of the unit 8888 ICIMA 850 P2 HSA J intcom E ee ee ee M eee eee eee eee Figure 1 1 Front View CAUTION 1 ee WARNING SSD e e e_n o _ D AWARNING C nD ans S N 0949200916 gt 2 26 a Figure 1 2 Back View J intcom User Manual Rev 1 02 2 JCIMA P2 Multi function PIM Analyzer MONITOR Figure 1 3 Left Side View Figure 1 4 Right Side View e Jointcom a User Manual Rev 1 02 3 e VGA Port For external display e USB2 0 JCIMA P2 Multi function PIM Analyzer For external keyboard mouse USB flash drives etc e 48VDC IN Port and Switch For DC Power supply and Power Switch e AUX Port RF IN port N type RF port 500 Impedance 10dBm maximum power handling e RF IN OUT Port 7 16 type RF Input Output port for maximum 2 10dBm to 43dBm RF output 500 Impedance 1 4 Accessories Item Name Picture Description Trolley Case Dimension 560mm 350mm 230mm Color Black Accessory Backpack Dimension 450mm 330mm 150mm Color Black Small Accessory bag 1 Dimension 270mm 200mm 120mm Small Accessory bag 2 J intcom Dimension 260mm 190mm 60mm ANI ath User Manual Rev 1 02 4 Item Name Small Accessory bag 3 Picture JCIMA P2 Multi function PIM Analyzer Des
28. 5N M for 7 16 type connector To make the measurement more accurate when PIM or RTF measurement continuously run more than 5 minutes please tighten the connector as the joint might be loosed by the heat effect generated during the high power test To protect the 7 16 connector of JCIMA P2 please use the 7 16F 7 16M adaptor which provided by manufacturer and replace it with a new adaptor regularly The C drive has been set as write protection please do not store any test reports and other data under C drive or desktop otherwise when the system is rebooted all stored data will be lost Jointcom User Manual Rev 1 02 104 Contacts NORTH AMERICA TEL 1 888 728 9443 FAX 1 416 900 6864 Email support acentury ca Address 175 West Beaver Creek Road Richmond Hill ON Canada L4B 3M1 Website http www acentury ca P R CHINA TEL 86 571 87381789 FAX 86 571 88911556 Address No 581 Huoju Avenue Binjiang District Hangzhou Zhejiang 310053 China Website http www jointcom com J intcom User Manual Rev 1 02 JCIMA P2 Multi function PIM Analyzer
29. Bar e The save setup window will pop up Save Path d reportispe Change Menu File Type File Name V CSV 2013 11 04 08 35 30 Save 2013 11 04 08 35 30 Cancel v JPG e Choose the file format can be multiple logs with different formats e Specify the file name then press OK button to execute Save command The test result will be saved under D Report spc with date and time automatically when using default name e After the test result is saved successfully the follow window will pop up Press OK button to quit the window Saving the C5 File successfully Saving the JPG file successfully 5 3 3 2 Read Saved Test Result e Press the READ softkey in the Command Bar e The Read CSV Report File window will pop up A 2009 01 02 19 24 44 csv OK Cancel e Select the file and press OK button to read the saved test result J intcom User Manual Rev 1 02 72 JCIMA P2 Multi function PIM Analyzer 6 Isolation Insertion Loss Measurement Function When pressing ISOLATION softkey in Function Option Section the Isolation Measurement function will be selected and the test interface will move to Isolation operation interface The isolation measurement function can be used to measure the isolation or insertion loss between ports of Device System under Test When pressing the ISOLATION softkey a warning notice will appear as below The prote
30. Bm to 40dBm 5 2 3 Frequency Setup lt Press the START softkey in the Command Bar input the start frequency and then press OK button to complete the setup StartFreg 869 000 eee Cancel ils lt Press the STOP softkey in the Command Bar input the stop frequency and then press OK button to complete the setup OK Cancel lt Press the Center softkey in the Command Bar input the center frequency and then press OK button to complete the setup MHZ CenterFreg 881 500 lt Press the SPAN softkey in the Command Bar choose the frequency span or press Other button to setup the customized span in the pop up span window Press OK button to complete the setup and quit the span window ZO00KHz SOOKHz 1IMHz 2MHz 10MHz a apas O OO O O im 20 000 100MHz MHz Erea ca 200MH z IL okher J intcom User Manual Rev 1 02 63 JCIMA P2 Multi function PIM Analyzer lt Press the RBW softkey in the Command Bar and choose the resolution bandwidth 1KHz LOKH2 LOOKH2 LOOOKHz 5 2 4 Setup for SCALE Press the SCALE softkey in the Command Bar and choose dB value per DIV for Y Axis LOE Diy SdB Div 2dB Div 5 2 5 Reference Position Setup Press the REF POSITION softkey in the Command Bar and choose DIV numbers for both X Axis and Y Axis REF POSITION Jointcom User Manual
31. E 20 2 3 1 Turn On Off PIM Analyzer and RUN the MCASULEIMENL sceeeessecececcccccccccesecseeeeeeeseeeeseesssseess 21 2 3 1 1 Power LO aatpe se stven an eninct caveaaus eSunteanaesanes oie cina nes caGalnbeaGncasisctaunnsoss eu none bactan cents SEEE EENES ENS EESSI oiea as Korets Enos 21 2 3 1 2 SLU I ON aaeeea E E EA S E E E E R E E E E ESS 21 2 3 2 F nctHon Status LEDS meirursireorn iana E a EEEE E E Eaa 22 233 Tabler LED SCION carrcira eien a E OE AT O EINO IAE NOO 22 PIM MEASUREMENT FUNCTION eeesesssseessssooeesecsoooesecsooecesccooeeecccsoceesccosecesccsoeeesessoeeesecsseeesecsseeeeecso 24 ed OPERATION INTERFACE sereen E E SE A 24 311 F NcHoOns OD TON SCCHON eseis ois E E TEA ATAA OOE EOE 24 3 1 2 POSE CUNE SECON sorrerara n E E ENEA EENE TE EEEE A EE A Ea 25 3 1 3 Test Result Evaluation SCCTION sis cis dice soicsencosmeitiosalsnigsanuoneuideusiseuiteedauouitfewseausuiu unsidedeeessucdesesSeeusenssaes 25 3414 TeStMOde Display SOCEON sccasiccssceszenecucsawevecpaaneddensavonidssseoedauaevancebactnadaceovansansssiuduchuuanconasandduabaless 26 3 1 4 1 Configured Parameters Of Test Carriers ccccccssscccccessccccsssecccceeseccccaeseceesaeseceesaeeeceeeaeeseeessuaeeesauaecessuaeecessaneeeenes 26 3 1 4 2 Sweep Mode and IM Intermodulation Product Orders MOde cccccccsssecccceesececceusecceseeeececeeuecseeaueceesaueeeessanes 27 Bede UE III ODOM avin caracosnCaueetien A A E A E O E E T E T E E NO 27 3 1 6 E Aa R a 1 i
32. Hz AWS TX 2110MHz 2155MHz AWS RX 1710MHz 1755MHz 3 3 PIM Measurement 3 3 1 Preparation before Measurement e As shown in Figure 3 11 connect the PIM Analyzer to Device or system under test and then to 50W Low PIM Termination via Low PIM test cable When running calibration for residual PIM directly connect the DIN port to 50W Low PIM Termination with Low PIM Test cable as shown in the dot line in Figure 3 12 Device System Under Test j Low PIM XC 50W Low PIM Test Cable Termination Figure 3 12 Setup for PIM Test A Please use the torque wrench to ensure the accuracy of measurement results Recommended torque 5N M for N type connector 17 5 22N M for 7 16 type connector When using torque wrench please confirm the arrow sign ds is facing outside When hearing click stop wrenching to provent over wrench J intcom User Manual Rev 1 02 36 JCIMA P2 Multi function PIM Analyzer e When using remote control terminal please confirm the WiFi and PIM LEDs in PIM Analyzer front panel are on Red 3 3 2 Start and Stop PIM Measurement Press the START button in the Command Bar the following warning window will pop up to remind the PIM Analyzer needs to connect the Low PIM Terminator before the PIM measurement starts Warning DUT Must Be Connected Before Test No Disconnecting During Test Yes After confirming with press Yes the PIM measurement will be started
33. IRE RISK OF USING THE PRODUCT ANY LIABILITY OF PROVIDER OR MANUFACTURER WILL BE LIMITED EXCLUSIVELY TO PRODUCT REPLACEMENT NO LIABILITY FOR CONSEQUENTIAL DAMAGES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW INNO EVENT SHALL JOINTCOM OR ITS SUPPLIERS BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS ARISING OUT OF THE USE OF OR INABILITY TO USE THE PRODUCT EVEN IF JOINTCOM HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES THE ABOVE LIMITATION MAY NOT APPLY TO YOU NOTICE Jointcom has prepared this manual for use by Jointcom personnel and customers as a guide for the proper installation operation and maintenance of Jointcom equipment and computer programs The drawings specifications and information contained herein are the property of Jointcom and any unauthorized use or disclosure of these drawings specifications and information is prohibited they Shall not be reproduced copied or used in whole or in part as the basis for manufacture or sale of the equipment or software programs without the prior written consent of Jointcom Jointcom JCIMA P2 Multi function PIM Analyzer Safety Precautions This produc
34. JCIMA P2 Multi function PIM Analyzer Valid Frequency Range MHz JCIMA 700 P2 732 764 Model Number JCIMA 850 P2 869 894 JCIMA 900 P2 930 960 JCIMA 1800 P2 1805 1880 JCIMA 1900 P2 1930 1990 1930 1990 JCIMA 1921 P2 and 2110 2155 JCIMA 2000 P2 2110 2170 JCIMA 2600 P2 2620 2690 Table 6 1 Valid Frequency Range for Isolation Insertion Loss Measurement 6 2 2 Y Axis Auto Regulation Press the AUTO SCALE softkey in Command Bar the curve display window will regulate itself automatically through adjusting the start and end value of Y Axis for better displaying The value of Y Axis will start from the minimum current measured result and end at the maximum result PIM RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2OTS TAT TS OSAS 12 0dB Di Tx 30 0dBm CALON O Peak 869 00MHz 5 864B Carrier Frequncy Sweep MHz SCALE PEAK AUTO SAVE READ SETTING ii init Jointcom AG User Manual Rev 1 02 76 JCIMA P2 Multi function PIM Analyzer 6 2 3 Isolation Insertion Loss Setting Window The Setting window is for calibration and parameter setup for Isolation and Insertion Loss measurement Press SETTING softkey in Command Bar the setting window will pop up as shown in Figure 6 3 Isolation Settings Tx bo 0 a dBm ATT 30 H dB Min Y 120 0 0B Max 0 0 dB Limit 80 0 dB Rev 0 0 dB Calibration Carrer Sta
35. Jointc Q User Manual V1 02 JCIMA P2 Multi Function Passive Intermodulation Analyzer Jointcom Communication Technology Co Ltd August 2014 Jointcom JCIMA P2 Multi function PIM Analyzer WARRANTY The Jointcom product listed on the title page is warranted against defects in materials and workmanship for one year from the date of shipment Jointcom s obligation covers repairing or replacing products which prove to be defective during the warranty period Buyers shall prepay transportation charges for equipment returned to Jointcom for warranty repairs Obligation is limited to the original purchaser Jointcom is not liable for consequential damages LIMITATION OF WARRANTY The foregoing warranty does not apply to Jointcom connectors that have failed due to normal wear Also the warranty does not apply to defects resulting from improper or inadequate maintenance by the Buyer unauthorized modification or misuse or operation outside of the environmental specifications of the product No other warranty is expressed or implied and the remedies provided herein are the Buyer s sole and exclusive remedies DISCLAIMER OF WARRANTY TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW JOINTCOM AND ITS SUPPLIERS DISCLAIM ALL WARRANTIES EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH REGARD TO THE PRODUCT THE USER ASSUMES THE ENT
36. JointcomPIM 7013001 No Internet access Dial up and VPN D08432013001 DUNI Wireless Network Connection e Click the icon at the left bottom corner of Windows GUI e Type mstsc then enter in search programs and files area Mozilla Firefox P D t d Microsoft PowerPoint 2010 ees Pictures Calculator EHI Music Computer Control Panel J Microsoft Outlook 2010 Microsoft Word 2010 Devices and Printers Default Programs m Adobe Reader XI Help and Support Microsoft Excel 2010 F Paint er Windows Fax and Scan al Notepad gt All Programs Shutdown gt Jointcom User Manual Rev 1 02 10 JCIMA P2 Multi function PIM Analyzer Eh pa See more results e The Remote Desktop Connection Window will pop up e Put the IP address of JCIMA P2 in Computer dialog then Click Connect j Remote Desktop 9 Connection Computer 192 168 0 188 Username None specified You will be asked for credentials when you connect i Show Options e The remote desktop will pop up Input Administrator as user name and 1 as password e Click OK to get access to the remote desktop 2 2 2 Setup for Android Based Operation systems JCIMA P2 supports Android 2 2 amp above operation systems To implement remote control feature the remote control software Jump Desktop needs to be installed in the Tablet PC There is li
37. L SETTING SAVE READ When system starts the velocity calibration the VELOCITY CAL softkey will turn to green And the softkey will turn back to normal when calibration complete Jointcom User Manual Rev 1 02 54 JCIMA P2 Multi function PIM Analyzer e After velocity calibration the measured velocity factor will be stored in the cable field in Setting window User can choose the velocity factor by enabling Prop for customized velocity factor or Cable measured velocity factor by velocity calibration Setting Setting M Settings r Settings Min Y 160 0 dBm Max Y 60 0 dBm MinY 1600 dBm Max Y 60 0 dBm ly Prop 0 71 0000 D a Prop 0 710000 imit 105 0 4 dBm Cable Loss 0 00 dB 100m Limit 105 0 dBm Loss 0 00 Default Defaut OK Cancel vim Cancel Prop Enabled Before Calibration Cable Enabled After Calibration 4 3 3 Start and Stop Measurement After the calibration press the START button in the Command Bar to start the measurement The START botton will change to STOP button During the measurement both the STOP button will and PEAK buttons will turn to green as show in the figure below Press STOP button any time during the test to stop the measurement SET START POWER PEAK RESOLUTTON DISTANCE LAST SET STOP POWER PEAK RESOLUT TON DISTANCE LAST The Command Bar will get back t
38. LED screen shows 1111 8 3 2 Start and Stop the 2 Harmonic 2 Order PIM Measurement e Press REV button in the Command Bar and then press START button in the Command Bar to start the reverse 2 Harmonic 2 Order PIM measurement When measurement starts both START and PEAK buttons will turn to green After measurement completes the START and PEAK buttons will turn back to normal e Wait until measurement complete or press STOP button again to stop the measurement e Press FWD button in the Command Bar and then press START button in the Command Bar to start the forward 2 Harmonic 2 Order PIM measurement When measurement starts both START and PEAK buttons will turn to green After measurement completes the START and PEAK buttons will turn back to normal e Wait until measurement complete or press STOP button again to stop the measurement 8 3 3 Save and Read the Test Result 8 2 6 1 Save the Test Result e Press the SAVE Softkey in Command Bar e The save setup window will pop up ae Save Path d reportihar Change Menu File Type r File Name m CSV 2013 11 08 02 07 42 JPG 2013 11 08 02 07 42 PDF 2013 11 08 02 07 42 modno here is no model no oe serno here is no serial no opeor default user Cancel Jointcom User Manual Rev 1 02 98 JCIMA P2 Multi fu
39. PA lt Table of Test Result Show the detailed PIM measurement result with table format lt gt General PIM Performance Show the Maximum Minimum and Average PIM result of the test lt gt PA performance Monitor Show the exact power level temperature and VSWR of each PA F1 and F2 The oe sign will turn to red when there is PA alarm triggered P1 dBm F1 MHz 43 0 869 0 43 0 43 0 SY Temp YSWR 13 Figure 3 5 PIM Test Report Section 3 1 7 Command Bar Press the command softkeys for PIM test setup and control Jointcom User Manual Rev 1 02 27 JCIMA P2 Multi function PIM Analyzer SAVE READ SETTING Figure 3 6 PIM Command Bar lt gt START Start or Stop PIM Measurement lt PEAK Show the Peak PIM lt gt SAVE Save the test result lt gt READ Read the saved test result lt SETTING Setup for PIM Measurement 3 2 Setup for PIM Measurement Press the SETTING softkey in the Command Bar as shown in below SETTING The Setting Window as shown in Figure 3 7 will pop up The Setting window is for setup of PIM measurement All standard PIM measurement setup is set as default by manufacture Press the Default button in the window to reset all the parameters back to default value SweepType Freq_Sweep SweepTimes 5 0 H F1 Frequency 869 0 a a715 869 0MHz 894 0MHz Power 143 0 10 0dBm 43 0dBm Freq Step 1 0 MHz Fe Frequency 889 0 H 1894 0
40. RUM softkey in the Function Option Section Figure 5 1shows the Spectrum Analyzer operation interface of JCIMA P2 Multifunction PIM Analyzer Function Option EA C PIM RTF SPECTRUM ISOLATION VSWR CONFIG LOCK QUIT 2014826154004 10 0dB Div ATT OdB RBW 1KHz Test Curve o Section Start 824 000MHz 2 5MHz Div Stop 849 000MHz Commana Bar o ANALYZE ATT START STOP CENTER SPAN RBW LAST NEXT Figure 5 1 Spectrum Analyzer Operation Interface 5 1 1 Function Option Section Please refer Chapter 3 1 1 for Function Option Section Jointcom User Manual Rev 1 02 58 JCIMA P2 Multi function PIM Analyzer 5 1 2 Test Curve Section As shown in Figure 5 2 the Test Curve Section shows the Spectrum measurement result Attenuation Resolution Setting Randwidth Marker Value Y Axis Power dBm 10 0MHz Div stop 394 000MHz Test Curve Peak Marker X Axis Freauencv Figure 5 2 Spectrum Test Curve Section lt Test Curve Yellow curve shows the spectrum of the receive signal lt RBW Show the setting resolution bandwidth lt ATT Show the setting attenuation level lt gt Marker Customized Marker marked in the measured curve lt gt Marker Value Show the frequency and power level of the Marker lt gt X Axis Frequency lt Y Axis Power level of the receive signal in dBm lt gt Test Mode Show the test mode under test Narrow or Wide Narrow is narrow band which is the receive band shown in Table 4 1
41. al Rev 1 02 95 JCIMA P2 Multi function PIM Analyzer AC ALCUN SweepType Freq_Sweep Time Points fiz E A fos00 4 fos00 3 g300mz 960 0MHz p Power 20 0 10 0dBm 43 0dBm 22 Gees Minimum Frequency Maximum Frequency Power 20 0 z 10 0dBm 43 0dBm etting attinas Min Y 14 dBm Min Y 14 H dBm Max Y 60 dBm Max Y 60 dBm Default Cancel e When under Time Sweep Mode only Minimum Frequency is available in Frequency Option area the gray areas are not selectable Hime Sweep B Time Points 12 ie Frequency 930 0 930 0MHz 960 0MHZz _ Step 50 MHz Gray Area F2 Frequency fo 30 0 4 960 0 930 0MH2z 960 0MHz Power 20 0 10 0dBm 43 0dBm Step 50 MHz HAR2 Settings PIM2 Settings Min Y 140 dBm Min Y 140 dBm Max Y dBm Max Y 60 dBm Donj oj o a 8 2 3 2 Power Setup In the Output Power Option Section as shown in 8 5 user can define customized carrier output power level The valid output power range is from 10dBm to 43dBm The minimum power step is 0 1dB J intcom User Manual Rev 1 02 96 JCIMA P2 Multi function PIM Analyzer 8 2 3 3 Frequency Step Setup The Frequency Step is used to setup the frequency sweep step when using Frequency Sweep Mode User can customizes the frequency step via changing the setting in Frequency Step Option Section which is shown in 8 5 The minimum fr
42. apter 3 1 1 for Function Option Section 8 1 2 Test Curve Section As shown in Figure 8 2 the Test Curve Section shows the 2 Harmonic PIM2measurement result Jointcom User Manual Rev 1 02 90 JCIMA P2 Multi function PIM Analyzer Tx Power Tx Frequence 2nd Harmonic Il Peak Marker Peak Value 2nd Harmonic ad eek Limit Line 2 Harmonic dB 2nd Harmonic ss Pass Fail limit dBm Test Curve A Q 80 Peak 119 2 dBm 2nd Order PIM Peak Value Freq MHz Time s dBm dBc lt i Vol hsta al Y Axis ay PIM Limit Line 2nd Order PIM dB 2nd Order PIM Test a Pass Fail limit dBm Cuver pe 80 Peak 118 4 dBm X Axis ScanFrequence Figure 8 2 2 Harmonic 2 Order PIM Measurement Test Curve Section lt 2 Harmonic Test Curve Yellow curve shows the Harmonic measurement result lt 2 Pim Test Curve Yellow curve shows the Pim measurement result lt gt Peak Marker Show the peak point in the curve lt 2 Harmonic Peak Value Show dB value of peak point for 2 Harmonic lt gt PIM2 Peak Value Show dB value of Peak point for PIM2 lt gt X Axis Frequency lt Y Axis 2nd Harmonic dB Value of 2 Harmonic lt 4 Y Axis 2nd PIM dB Value of 2 PIM lt gt TX Power Transmission power of the Power Amplifier lt 2 Harmonic Limit Line Line of limit which user uses to evaluate test result lt gt 2 Pim Limit Line Line of limit which user uses to evaluate test result Joi
43. apter 4 3 2 for detail process of Calibration Jointcom User Manual Rev 1 02 47 JCIMA P2 Multi function PIM Analyzer 4 2 6 Calibration for Velocity Factor Press the VELOCITY CAL softkey in Command Bar The following window will pop up Input the type and length of the RF cable under test Cable Type Cable Length 10 00 m OK Cancel Figure 4 9 Velocity Factor Calibration Setup Window After pressing OK button the Calibration process will be started and the pop up window will be closed automatically Please refer Chapter 4 3 2 for detail process of Calibration 4 2 7 SETTING Softkey Press the SETTING softkey in Command Bar the Setting window will pop up as shown in below r Settings MinY 1600 dBm Max Y 60 0 dBm V Prop 0 710000 l Cable J DEL Limit 105 0 dBm Cable Loss 0 00 dB 100m Defaut OK Cancel Press OK button to save and exit Setting Window 4 2 6 1 Setup for Y Axis Range Input the minimum and maximum PIM value in Min Y and Max Y respectively to set up the Y Axis display range 4 2 6 2 Setup for Velocity Factor In order to make the distance to PIM fault measurement more accurate when user knows the velocity factor of the RF cable under test input the velocity factor in the Prop option If user doesn t know the velocity factor of the RF cable under test please leave it as default value 0 71 Jointcom
44. arrowband thers Test Mode OK Cancel File Manage lt gt Broadband for measurement via AUX port N type Connector only The frequency range for broadband is from 100MHz to 3GHz lt gt Narrowband for measurement via RF IN OUT port DIN Connector only The frequency range is different from JCIMA P2 model Table 5 1 shows the detail frequency ranges for different JCIMA P2 models Jointcom User Manual Rev 1 02 61 JCIMA P2 Multi function PIM Analyzer AUX Port DIN Connector for broadband measurement RF IN OUT Port N Type Connector for broadband measurement AN Caution The maximum input power on for both AUX and RF IN OUT ports must be less than 10dBm Model Number Narrowband Frequency Range MHz 698 716 779 5 804 5 JCIMA 850 P2 824 849 JCIMA 700 P2 JCIMA 900 P2 885 915 JCIMA 1800 P2 1710 1785 JCIMA 1900 P2 1850 1910 JCIMA 1921 P2 1710 1910 JCIMA 2000 P2 1920 2060 JCIMA 2600 P2 2500 2570 Table 5 1 Frequency Ranges for Narrowband Mode 5 2 2 Reference Level Setup Press the REF LEVEL softkey in Command Bar to configure value for the internal attenuator ATT The valid range is 0 50dBm in 10 cB step AE AB J intcom User Manual Rev 1 02 62 JCIMA P2 Multi function PIM Analyzer The default reference level is dBm with 40dB internal attenuator which means the dynamic range shows in Y Axis is 140d
45. assive intermodulation measurement which helps to evaluate or troubleshoot the PIM issue of Device System under Test 3 1 Operation Interface Press the PIM softkey in Function Option Section The JCIMA P2 will get access to the PIM operation interface default interface after turning on the JCIMA P2 Figure 3 1 shows the PIM operation interface of JCIMA P2 Multifunction PIM Analyzer Function Option Sn PIM RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2013 10 25 23 20 07 100 0 7 A 120 0 Test Curve Section Test Result Evaluation Section Pass Fail limit dBc 163 945 29 948 72 949 1A 940 A Test Mode eee 849 16 9E BO Pispia prec ion Freq MHz Time s IMS IM5 1M7 IM9 dBc Im3_F MHz Im3 V dBc 844 0 Test Report a Section z Command Bar SETTING Figure 3 1 PIM Operation Interface 3 1 1 Functions Option Section The Function Option Section is for test measurement function selection PIM RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2013 10 25 23 20 07 lt PIM For Passive Intermodulation Measurement lt RTF For location of PIM and VSWR Failure Measurement lt SPECTRUM For Spectrum Measurement Jointcom AW ei User Manual Rev 1 02 24 JCIMA P2 Multi function PIM Analyzer lt gt ISOLATION For Isolation Insertion Loss Measurement lt gt VSWR For VSWR Return Loss Measurement lt HARMONIC For 2nd Harmonic Measurement lt gt CONFIG For c
46. asurement Press SETTING softkey in Command Bar the setting window will pop up as shown in Figure 7 3 settings Tx dBm Att 30 dB VSWR Limit 1 3 l RL Limit dB Min VSWR MinRL 00 la wi Max VSWR MaxRL 500 4B Calibration Carer Start Figure 7 3 Setting Window for VSWR Return Loss Feature lt gt Tx dBm RF Transmission Power for the measurement 10 30dBm lt gt ATT Internal attenuation for receive spectrum analyzer O 40dB lt gt VSWR Limit Limit line setup for the test lt Min VSWR The start VSWR value of the Y Axis lt gt Max VSWR The stop VSWR value of the Y axis lt gt Min RLS The start Return Loss value dB of the Y Axis lt gt Max RLS The stop Return Loss value dB of the Y axis lt gt Calibration For Calibration before measurement lt Default Set all parameters back to manufacture setting Jointcom User Manual Rev 1 02 85 JCIMA P2 Multi function PIM Analyzer 7 2 4 Switch between Return Loss and VSWR In Test Curve Section when pressing Unit Bar the Y Axis display Unit can switch between Return Loss and VSWR The default display is Return Loss in dB a G a Se Sars Carrier Freqency Sweep MHz Carrier Freqency Sweep MHz 7 3 VSWR Return Loss Measurement 7 3 1 Calibration before Measurement e Connect the PIM Analyzer for calibration setup as shown in Figure 7 4 INPUT OUTPUT Port Coupling Port Figure 7 4 Setup for VSWR Return Loss Calibr
47. ation Jointcom User Manual Rev 1 02 86 JCIMA P2 Multi function PIM Analyzer Recommended torque 5N M for N type connector 17 5 22N M for 7 16 type connector Please use the torque wrench to ensure the accuracy of measurement results e Press VSWR softkey in Function Option Section to access the VSWR Return Loss operation interface e When using remote control terminal please confirm the WiFi and VSWR LEDs in PIM Analyzer front panel are on Red aod e Press SETTING softkey in Command Bar e Leave all options as default in the Setting Window e Press Start button to start calibration e Press OK button to close the Setting window settings Tx dBm at 30 dB VSWR Limit Wd Min VSWR 1 0 Z Calibration in progress Calibration Camer CDe Start Calibration 7 3 2 Start and Stop the VSWR Return Loss Measurement 7 3 2 1 Test Setup Figure 7 5 show the test setup for VSWR Return Loss measurement INPUT Port Low PIM Test Cable zh System Under Test Coupling Port a SAS 50W Low PIM e Termination J intcom User Manual Rev 1 02 87 JCIMA P2 Multi function PIM Analyzer Figure 7 5 Setup for VSWR Return Loss Measurement 7 3 2 2 Start and Stop the measurement e Press START button in the Command Bar to start the VSWR Return Loss measurement When measurement starts both START and PEAK buttons will
48. by frequency information of the device or system under test for the compensation of the spectrum measurement e Press the OFFSET OPTION softkey in the Command Bar e Enable the TestMode in Offset Option Window e Choose the offset file then press ENABLE button Offset Option E Onset Data File C Program Files Pil Misettingstspectrum_TablesiCh 4kt Browse 1KHz2 NARROW BIND i E Seale 14 0 14 4 14 5 i E g SQOQOM Az l TestMode Enable Disable 5 2 14 Channel Power Measurement JCIMA P2 Spectrum Analyzer function allows user to measurew channel power of RF signal e Press the CHANNEL POWER softkey in the Command Bar as shown in Figure 5 3 The Channel Power setup window will popup J intcom User Manual Rev 1 02 69 JCIMA P2 Multi function PIM Analyzer Channel Power Cent Center ere 836 500 MH ENAP ros e Input the Center Frequency and Channel Bandwidth and then click OK button The Channel Power Measurement will be shown in figure as below PIM RTF SPECTRUM ISOLATION VSWR CONFIG LOCK QUIT 2014 8 26 15 43 39 m a eer Start 835 000MHz 0 3MHz Div Stop 838 000MHz CHANNE SAVE READ SCANT TMES POWER BACK TOP X Axis Test Curve Frquency MHz Jointcom User Manual Rev 1 02 70 JCIMA P2 Multi function PIM Analyzer 5 2 15 Spectrum Measurement 5 2 16 Preparation of the Measurement e Connect the PIM Analyzer to System Under
49. ceesececeeseceesueeesseeeseseeees 51 4 3 2 1 O Meter Calibration for RTF Test MOCeC ccccccssecccesscccesscccesceceesceeeeeceeeneceseeececauececeuecessnecesanecesanecetsuecetsuecetanasss 51 4 3 2 2 O Meter Calibration for VSWR Test MOC Giicccccsccccccccssvavenssscanscascnapenessdarcnensnanaesvecenenassoapenssadenseascnavanesasanenevavanaeavedenens 52 4 3 2 3 Velocity Factor Calibra escanas crea E ET EET E EE EEEE 54 433 Slariand Stop Measurement a sctescateccavesesessatedcasaumansdenavevendssueatcassendecasneancecoatasedsarsaidcsetndecasaunes 55 4 3 4 Distance to PIM and VSWR Test RESUIt sssscsesesssesssrcesscserssssseesecscsessscssencasssssssssssensaseseeneees 55 Jointcom JCIMA P2 Multi function PIM Analyzer 43 5 Saveand Read RTF Test RSUIt sciisdccscctodenssavotessesssecsceuvelevdasbodeecesvedeedessceeseesselvetedeedverosdevensdxeewess 56 AD Ble SW NS Tet Pa I erer eroicenst teasacneisveseeatkamtaciats EE EO demeaceta ea enceedantacats tienes tlantacetane neat eecaceenennaeost 56 4 3 5 2 Re d Saved Test RESUIE sccceoshwessnctseaisotdanadaenintwdsanolseaiawatiwad seston seaxtmacdiadebawatenitiwadanoheadiananines stutawadsustawal setdunchaxiniedsabolawaianons 57 5 SPECIRUMANALYZER sacesesacoscvevevessvesns onua ENE EE A E 58 91 OPERATION INTERFACE sec cicnetrcotec eunoaeoncuenteensuoesscacwones ArNCO REA AEE EAEE O N EEE EA KENEEN 58 5 1 1 FUICCON OD COI SECON wcsanaisiamnncicvaswecsianasesaebincoaatedewniannieorisanrenniea
50. cense fee for Android based Jump Desktop Jointcom covers one Jump Desktop license with the Tablet PC delivered together with JCIMA P2 To acquire extra Jump Desktop license the cost will be covered by user s own expense 2 2 2 1 Remote Control Desktop Software Download If the remote control terminal is not provided by manufacture go to Play Store for Android based Smart Phone or Tablet search Jump Desktop and then install the Jump Desktop After installing the SW the Jump icon Will be shown in the interface J intcom aa User Manual Rev 1 02 JCIMA P2 Multi function PIM Analyzer 2 2 2 2 Wireless Connection Setup e Get access to the WiFi networks setting in Android Tablet e Choose the JCIMA P2 connection JointcomPIM xxxxxxx xxxxxx is the serial number of the PIM Analyzer e Click Connect and confirm the JointcomPIM xxxxxxx is connected as shown in the figure below settings Q scan Wi FiDirect Wireless and networks S Wi Fi wii oS Bluetooth Wi Fi networke D08432013001 onnected RDDJ Data usage Secured WPS Available sa Thunderbolt eee More settings Secured F wirelesscomm wes avaicbi m di g Blocking mode E o ma Sound Display a Storage Power saving mode 2 2 2 3 Remote Desktop Setup e Double press Jump Icon in the window to access remote control desktop e If it s the first time usin
51. cription Dimension 180mm 150mm 25mm Low PIM Termination PIM3 s 168dBc 2 43dBm Frequency Range DC 3GHz Impedance 500 Model Number JCLD 0830 50 041IMF Connector Adapters 4 ie a ih MHN sw WN Model Number and Description AD DD02 7 16F 7 16F AD DD01 7 16M 7 16F AD DNO1 7 16M NF AD DN02 7 16F NM Low PIM Test Cable QQ PIM3 lt 171dBc 2 43dBm Impedance 500 Model Number CKO5 1 1m 1 meter NM NM CK04 1 3m 3 meters 7 16M 7 16M CK03 1 3m 3 meters 7 16M NM PIM3 Standard Adapter MyM 0dBe PIM3 80dBm 3dB 2 43dBm or 110dBm 3dB 2 43dBm Type 7 16M 7 16F Impedance 500 Model Number Sxxx 100 xxx is the frequency band e g 850 means 850MHz Band Torque Wrench NB 25 DIN Connector Torque Wrench NB 5 N Type Connector Torque Wrench Attenuator Jointcom 30dB 2 Power Capacity 5W Frequency Range DC 3GHz Impedance 500 User Manual Rev 1 02 5 Item Name Adaptors for VSWR Picture Ill omw gt a w e JCIMA P2 Multi function PIM Analyzer Description JCCP 0707 50 01 R1A for 850MHz band JCCP 0808 50 01 R1A for 850MHz band JCCP 0909 50 01 R1A for 900M band JCCP 1818 50 01 R1A for 1800M band JCCP 1919 50 01 R1A for 1900MHz band JCCP 2121 50 01 R1A for 2000MHz JCCP 2626 50 01 R1A for 2 6GHz band 2W Load Power Capacity 2W Frequency Range DC 3GHz Impedance 500 AC DC Adapter JCADT 11
52. ction AN attenuators 2 x 30dB fixed attenuators provided by manufacturer are required to connect the AUX port N type Connector to confirm the input power less than 10dBm Warning Attenuator 60dB Must Be Connected Before Test OK 6 1 Operating Interface Figure 6 1 shows the operation interface of Isolation Measurement Function Funai Opon PIM RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT Section Test Curve Section 1 Carrier Frequncy Sweep MHz Command Bar FREQ AUTO ws RANGE PEAK SCALE SAVE READ SETTING Figure 6 1 Operation Interface of Isolation Measurement Function Jointcom User Manual Rev 1 02 73 JCIMA P2 Multi function PIM Analyzer 6 1 1 Function Option Section Please refer Chapter 3 1 1 for Function Option Section 6 1 2 Test Curve Section As shown in Figure 6 2 the Test Curve Section shows the Isolation Insertion Loss measurement result Tx Power Calibration status 2 0dB Div Tx 30 0dBn CALON Peak a AE Isolation Value qm Test Curve Y Axis Isolation dB q Limit Line Carrier Frequncy Sweep MHz X Axis Peak Marker Frequency Figure 6 2 Isolation Test Curve Section lt gt Test Curve Yellow curve shows the Isolation Insertion Loss measurement result lt gt Peak Marker Show the peak point in the curve lt Peak Isolation Value Show the frequency and isolation insertion loss value of peak point lt X Axis Frequency lt Y Axis Isolation Le
53. d tees aur onnsdibeeneanameaneasbeeneataees 58 5 1 2 CVE O TO a TENA 59 5 1 3 CONT LOT oee E E E T E A E E naar eesven 59 De SETUP FOR SPECTRUM MEASUREMENT snsstescuntrencadtencoundsrcdanensenncndbeaetanbodosandaievaayunieacqudteancavenanaerdennuasenss 61 5 2 1 Test MOUE SE UD irria i iien ni OTi EAE OE UEIN OONO 61 522 Rejerence Level SetU seririrr eiris nran TE NEEDE OEE EAE NE OEN EE TT 62 5 2 3 EEE Ea e AIAN E A E A EAS A A AE E EEE 63 SeA T A a E E E E E E E E EE 64 529 Reference Posion SelUDesiiiseerinirearis cerei ens EN E NEE EA E A EEEE 64 5206 FNE MON TS ran EE E E E NEE EE ENA EA NE E EEE 65 527 Seluprreguency or MOrKETS esrerir ieseni erien ros NE EE ETONE 65 5 2 8 Move the marker to Peak POWEL cccccceeeccceeescceecsccvecscececsccessceessuecsseecsseeessseeesssueesseeessneeesens 65 5 2 9 Setup for External Attenuation Compensation ccccccseesecccsesececceececccuesececeusecsssuseesseuesecessseeeeas 65 EO TOAMNA E E I EE EAE N A E E 66 5211 TERNO TFUNC ON errire EEE ENE ENE EENE NEEE EEEE ENE EENE Ea 66 5 212 QuickSpan Shift Command sec soccicecicnciacasrccessabsecapsugecasatodoaiianeddnvesncbsedadseesmedbelevaiteeddusseeviacsuedseeae 69 52 13 1LOQ0 Offset File Or GOMPCNSQTON cosiccscrctccoscinstccrendeevaindasiest EEE NEA OE N 69 5 2 14 Channel Power MCASULCIME Nh cccceeececeeeccceeeccceecscsuecscececsceuessueesseecsseuecssececeseeessseeesseessseesens 69 5 2 15 Spectrum MCOSUIEINER icassccncescavacecostenaie
54. e SYSTEM oo 5 384 K Isass exe SYSTEM 00 1 324 K services exe SYSTEM 00 4 716K ee ere O cstss exe SYSTEM Windows assiFail limit d pm sins x6 SYSTEM IF you shut down this remote computer no one can use it until someone at the remote location manually restarts it 80 CG J Show processes from all users e YY Do you want to continue shutting down Yes No 3m NO F1 dBm F1 MHz P2 dBm F2 MHz Im3_F MHz Im3_ dBm MaxPIM 0 0 MinPIM 0 0 dBm AvgPIM 0 0 dBm Processes 29 CPU Usage 3 Power Temp YSWR SETTING Jointcom User Manual Rev 1 02 19 JCIMA P2 Multi function PIM Analyzer Only one terminal can control the PIM Analyzer at a time So when the 2 remote terminal tries to connect the unit while the original remote terminal is still connected the original remote terminal will be disconnected A following window will be popped up Connection closed by server Another user connected to the session Code 5 OK If user wants to keep using the original terminal press OK button in the pop up window The connection will be switched back to the Jump window for reconnecting the PIM Analyzer Pim Werooms IOMON Coston 2 3 Front Panel Control There is a LED display for local control and test status power supply status monitor Function Local Control Status LEDs LED Screen Panel Start Button Power Button Figure 2 1 JCIMA P2 Front Panel J intcom User
55. e window to reset all the parameters back to default value cro ae SweepType Freq_ Sweep Time Points F F Frequency a300 4 9600 4 930 0MHz 960 0MHz Power 200 4 10 0dBm 43 0dBm Step 5 0 MHz F2 Frequency 930 0 s600 930 0MHz 960 0MHz Power 20 0 10 0dBm 43 0dBm Step 5 0 MHz HAR2 Settings __ r FIM Settings Min i 140 dBm Min w 1 140 3 dBm Marr 60 dBm Max r 60 dBm Default Cancel Figure 8 4 Setting Window for 2 Harmonic 2 PIM Setup J intcom User Manual Rev 1 02 93 JCIMA P2 Multi function PIM Analyzer 8 2 1 Test Mode Setup There are 2 test modes Frequency Sweep and Time Sweep 8 2 1 1 Frequency Sweep Mode When under Frequency Sweep mode the PIM Analyzer will sweep 2 RF carriers with defined frequency range and power level and measure the PIM performance 8 2 1 2 Time Sweep Mode When under Time Sweep mode the PIM Analyzer will generate fixed RF carrier set by user and perform the PIM measurement by time 8 2 1 3 Setup Test Mode In Sweep Type option of Setting Window when choosing Freq _Sweep the PIM measurement is Frequency Sweep Mode SweepType j When choosing Time_Sweep the PIM measurement is set to be Time Sweep Mode 8 2 2 Sweep Times Setup In Sweep Times setup of the Setting Window user can define the sweep times More sweep times is chosen
56. eeeeeceseeeeceuseeeeeeceeseeeeees 7 2 2 SETUP AND OPERATION OF WIRELESS REMOTE CONTROL cscescscceceececcecceceeenecuceeceeeuececeeeeeeseeseseeeeeceeeeeeeees 9 2 2 1 Setup Remote Control Window for Windows SYStCIM ccccsssscccceesecseceesceccesecesesecssseseesssesesseeees 9 2 2 2 Setup for Android Based Operation SYStTCIMS ccccsesccccsseseccceesececsesceseceeseceseusecssseeeeseeeesecesauseestas 11 2 2 2 1 Remote Control Desktop Software Download ssssesssseessressreresrrssrerssressreresrersrrrssrerssrresrresstersserseeresereseeersrerseereseeess 11 Deke Nire S Connection SETUD erreser ners rr etnei EREE EEEE REOR EENE OEO EREE OEEO EE EREE EEE EEE EEE OR 12 P RENO EDES O E Dirac S E E E 12 2 2 3 Remotely Control the PIM Analyzer ssccccccsesecccceseescceeseccceusecscsuseesecueseceseusecsssuseeseseusecessuseestas 15 2 2 3 1 Access Test Window of PIM Analyzer siicedsidevcsseniswesssiacwdavesieweassidivsasenddwodseaianndsndlocndsvinsadisvabeacdaviieadaspneandssssienispubincdasees 15 Eene EVOA eE A EEA AEEA AE EEE EE EEO EEE E EEE 15 2 2 3 3 Quit and Re access to Test WiINdoW ccccccccceccccsecccucsceucseeuceuuececucseeuceeeuseuuesseucseeuseueuseuessenseeeussueuseuueseeuseeeuseueuseueseanss 16 222 94 EXE REMOTE CONNECTION scsccennadseedscecaxanvcesnsessnvenvesxedunsisbcanecssiacaneas EEEE ATEO EE EON EEE AE OOS EAE NEETA 18 2S FRONTPANELCONTROL ics tscciacastwccateesuectacsaciendena vee cacnaduteedtetuaeames naclaedes seed AEE E
57. el 4 1 4 Command Bar RTF Command Bar is for RTF measurement setup control and test result saving or reading e Press NEXT button to show the extended Command Bar e Press TOP or BACK button in the extended Command Bar to move back to original Command Bar SET START POWER PEAK RESOLUT TON DISTANCE LAST NEAT O METER VELOCITY CAL CAL SETTING SAVE READ TOP Figure 4 4 RTF Command Bar lt gt Start Stop Start or Stop RTF Measurement lt gt Power Power level setting for RTF measurement Jointcom User Manual Rev 1 02 44 JCIMA P2 Multi function PIM Analyzer o ooo ooo ooo PEAK RESOLUTION SET DISTANCE LAST NEXT O METER CAL VELOCITY CAL SETTING SAVE READ BACK TOP Mark the Peak PIM or VSWR Setup the number of the test point Setup the distance range Move to the last page of the Command Bar Move to next page of Command Bar Setup and start the calibration at O meter Calibration for velocity factor of RF cable under test Setup for Y Axis range Velocity Factor Cable Type Cable Loss and Threshold Save the test result Read the saved test result Back to former page of Command Bar Back to the first page of Command Bar 4 2 Setup for RTF Measurement 4 2 1 Mode Setup for RTF Measurement Under RTF function there are 2 modes distance to 3 Order PIM measurement RTF and distance to VSWR measurement VSWR Click the RTF or VSWR options under M
58. equency step is 0 1MHz When under time sweep mode this option is not available and the selection area will turn gray 8 2 3 4 Set up the Max Min value of Y axis SweepType fTime_Sweep M Time Points 12 4 F1 2 fo 4 930 0MHz 960 0MHz Frequency 1930 0 Power 200 10 0dBm 43 0dBm Step z MHz F2 Frequency f 4 E 930 0MHz 960 0MH2 Power 20 0 H 10 0dBm 43 0dBm Step 4 MHz ni PIM2 Settings Min Y 140 dBm HAR2 Settings The Max Min value Miny 140 dBm setup for 2 Harmonic The Max Min value setup for 2 Order PIM Max Y 60 H dBm Default OK Cancel Setting the value of Max Y and Min Y to adjust the displayed scale of 2 Harmonic 2 order PIM Max Y 1 60 dBm 8 3 2 Harmonic 2 Order PIM Measurement 8 3 1 Preparation Before the measurement e Connect the PIM Analyzer for measurement setup as shown in e Figure 8 6 Low PIM Test Cable System Under Test Adapter 50W Low PIM i Termination d 2 Harmonic Figure 8 6 Test Setup for 2 Harmonic 2 Order PIM Measurement A Please use the torque wrench to ensure the accuracy of measurement results Recommended torque 5N M for N type connector 17 5 22N M for 7 16 type connector J intcom User Manual Rev 1 02 97 JCIMA P2 Multi function PIM Analyzer e When using remote control terminal please confirm only WiFi LED in PIM Analyzer front panel is on Red and the
59. essvwaenagtiund Seadensuhsaeastanavansioayneseins 40 33 5 41 Save the FIM Test Result igoicskscacacaccnadancseuicacatasadavatseddanabesseeuasauacasatansl nadceuddacacasataud sheadanahessuandiandeaiatabAlandseuaeteatssauaeas 40 3 3 5 2 Read Saved PIM Test R SUIt ccc ccscccssscccesececsesccceececsuececeeececeuececsnecetaneceteeecesenecessneceseuecessuecetenecetsncetsuecetsnseegees 41 DISTANCE TO PIM AND VSWR RTPF cscsccscsccscescsccccscsscccsccccscescscescscsscccsceccscesscssescsseccscescscessscess 42 AL OPERARON INTER AC E er E E ese 42 4 1 1 Function Option SCCUON wessacesacaszcrszverdvesavancdessunsedarvvadeues suostuarebadidestansdasndadeuesweariiasabenecesivonadesazatn 42 412 Tes Setup Display SOCUON rirerire nrinn n ENE EN TENE G 42 4 1 3 TE CUE O a Er E E atatducaaeeeaneeein 43 4 1 4 COMMON BAT aan aaa AAA EEA atad mattantnananageasreeneee oe 44 4 2 SETUP FOR RTF MEASUREMENT ssessssssssesesessesesersrersersrseserreseseoresesesersrsesresrsesersesreeeseseseoreseeeoreseseseeseseeee 45 4 2 1 Mode Setup for RTF Measurement scccccseeseccenseescceesececesecsssusecsssueeesscesecessusecsssueeseseeesessess 45 A22 SEPIO POWT LOVE eeni a n nn EOE NNNNA 46 A R O 0 ae E A A E E O E T S 46 424 Seluplor Distance ONS reieceiceiei priren eo neari inar EEEE ENEAN TETERE NEE NEES 47 7s i oo AO Ona O MOT er E E EREE E EEA 47 4 2 5 1 Calibration at O meter under RTF Test ModE ssssssssssrsesssesssersssesressrrsasrnosouritvs star
60. euseseensessesecesesecssusestesesssnsesseeses 34 3 2 8 Save or Set Back Default Setting ccccccsesccccseseccccesececeusecsccsecsccuesesecesecessesecsssuseeseeeesecessseeseas 34 3 2 9 Frequency Band setup for Dual band Model only ccccccsseececcccsneseeccccceeeccseceeseesssseeeeeeseseenens 35 3 2 9 1 Band setup Tor ICMA 700 P2 aac cetera ces eeeasactate vaca cians ac atatteewe EEEE EEEE ETENUNE PEENED EE EET Es EEES 35 3 2 9 2 Band setup TorJCIMA 1921 P2 scrnicsssvarceniesseniawaasuinansavealanad vitedeiseniasedsuiatasistaieaedsniaedeispubeandayiarenasentnandesnandonsaaiiaasnes 35 o UIE SUR EN EI cocer Tano E E ose aneranocsuanets 36 3 3 1 Preparation before Measurement scscccceesecccsseeecsuesesecesecessesecsssusessceusecessusecsssusestseesesessess 36 3 3 2 Start ANd Stop PIM Measurement cccseecccesececsccccesecccesececusecssusesseusessenecesesecssusestausesssusessanses 37 3 33 Calibration for PIM Measurement ccseccccesesecccceesececesececsusecsscueseseceusecessuseesssusesecsesecesanseeenes 38 3 3 3 1 Residual INTELTMOGUIGLION sinsicaravocsarssrpecieasusncdonsnonitobeuaneceesninduabsvansdnssvedstapavavadnsavagctnssusnedathoniiobevent 38 3 3 3 2 Calibration for Standard Adapter ccccccseseecccsescccccsccccceeseccccesececsuseeseseuseceseusecssseseessseusesssauseeees 38 Bo PM TOS RCS i eases ah aca teturasan A E E T moaaadanes 39 3 3 5 Save and Read PIM Test RESIN wiz vcossinncessdinnvannnasiaiasvanviaaeoddbonanQ
61. g Jump Desktop choose Manual Setup Jump Automatic Setup Manual Setup wiiqur a computer manually by enter sy setup work address Mt e After pressing Manual Setup Add Connection window will pop up In the field of address row input the IP address of PIM Analyzer 192 169 0 188 choose RDP for Connection Type and then press Save to access Edit window J intcom User Manual Rev 1 02 12 JCIMA P2 Multi function PIM Analyzer Add Connection Address 192 168 0 188 Connection Type ADP Cancel e Press Display Name to input the name of display and then Save to get back to Edit Window Display Name e Press Auto LOGON input administrator and 1 for Username and Password respectively in the pop up window Then press Save button om e Press the Icon at the left top corner of Edit window J intcom User Manual Rev 1 02 13 JCIMA P2 Multi function PIM Analyzer Windows Credentials Hsemame administrator Password Domain e Press SCREEN Resolution and set 1024 768 as display resolution Press Save to save and quit the display resolution window Width 1024 Height TOS Presets Custom Cancel Please also refer to the following Web link for the support and user guide of related Jump Desktop version http support jum
62. he READ softkey in the Command Bar e The Read CSV Report File window will pop up 2009 01 02 19 24 44 csv OK Cancel e Select the file and press OK button to read the saved test result Jointcom User Manual Rev 1 02 80 JCIMA P2 Multi function PIM Analyzer 7 VSWR Return Loss Measurement JCIMA P2 provide the VSWR Return measurement function which helps the user to evaluate or troubleshooting the VSWR Return Loss issues either in the field or lab 7 1 Operating Interface Press the VSWR softkey in Function Option Section The VSWR Return Loss Measurement function will be selected and the JCIMA P2 will move to VSWR interface as shown in Figure 7 1 Function Option Section Test Curve Section Carrier Freqency Sweep MHz Command Bar PEAK IIT SAVE READ SETTING RANGE SCALE Figure 7 1 Operation Interface of VSWR Return Loss Measurement Function 7 1 1 Function Option Section Please refer Chapter 3 1 1 for Function Option Section Jointcom User Manual Rev 1 02 81 JCIMA P2 Multi function PIM Analyzer 7 1 2 Test Curve Section As shown in Figure 7 2 the Test Curve Section shows the VSWR Return Loss measurement result Unit Bar Y Axis VSWR or Return Loss dB Tx Power Calibration status 4 OdB Div x 30 0dBm Rx 45 5dBm 40 0 Peak 869 00Hz 29 984B OTE 79 0 s ai Fregency MHz Peak Marker X Axis Frequency Figure 7 2 VSWR Re
63. hile the RF OUT port is not proper terminated 2 Make sure the RF output is turned off when connecting and disconnecting the cables 3 Connecting well or not will impact the test results In order to reduce the testing error please ensure all connectors are connected correctly with using the torque wrenches provided by Jointcom 4 The test cables low PIM shall not be distorted seriously 5 The test cables and adaptors which should be low passive intermodulation are vulnerable parts Once any non performing such as loose instable etc be found replace them timely 6 In order to extend service life of the equipment please use the 7 16F 7 16M adaptor which Jointcom provided by manufacturer and replace it with a new adaptor regularly JCIMA P2 Multi function PIM Analyzer Table of Contents 1 2 3 OVE VEY irre consa savas eats cea canine eats cocneesecuseued ones aunts E E E 1 LL IVR IONS carrer are tees reer a E A EEN 1 1 2 JCIMA P2 MULTI FUNCTION PIM ANALYZER FUNCTIONS cccccccceccsceccseeceseucuscucuseueuseueeseseuceseeseseueuseususeuees 1 1 3 JCIMA P2 MULTI FUNCTION PIM ANALYZER EXTERIOR ccceccecceceecuccecceceeeuccecceeeeeusceseeseeeueeeseeeeeeeseuseeeueens 2 LA ACE Sh Pee Oe cere ee eenen eee 4 OPER TON iar iar occ ceca aces cctsps nice eae atin ics ease cece vias ns nw bre eee OEE 7 2 1 TURN ON AND TURN OFF THE PIM ANALYZER cccecceceececcecceceeeucceceeneeucceceesuececeecse
64. il limit setup popup window in the right 2 Soft keyboard provided by Jump Desktop Press softkey on Android based Tablet The command bar of Jump Desktop will show in the bottom of the screen SNASWVS ee Soft Keyboard Command bar of Button Jump Desktop Press the soft keyboard button to bring out the soft keyboard and input data 2 2 3 3 Quit and Re access to Test Window Press QUIT button at right top corner of test window to exit test window still in remote desktop J intcom User Manual Rev 1 02 16 JCIMA P2 Multi function PIM Analyzer PIM RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2013 10 25 23 20 07 100 0 120 0 160 0 180 0 ees Pass Fail limit dBc 200 0 x op S ee a OBE 2 845 28 846 72 848 16 849 6 Freq MHz Time s IMS IMS 1M7 TM9 dBm P1 dBm F1 MHz P2 dBm F2 MHz Im3_F MHz Im3_V V dBc 43 0 869 0 43 0 894 0 844 0 177 6 43 0 870 0 43 0 894 0 846 0 174 5 43 0 871 0 43 0 894 0 848 0 172 4 Power Temp VSWR A Fl 43 1 235 1 3 I Fz 429 245 READ SETTING H Double press PIM icon to re access test window User Manual Rev 1 02 17 2 2 3 4 Exit Remote Connection Press Ctrl Shift ESC at Jump Desktop menu JCIMA P2 Multi function PIM Analyzer Peak B46 7 249 6 M7 1M9 Freq MHz Time s dBm F2 MHz SVYCHOST EXE ctfmon exe rdpclip exe spoolsv exe explorer exe svch
65. indow 3 2 9 1 Band setup for JCIMA 700 P2 e Press the CONFIG softkey in Function Option Section The Global Configuration window will pop up e Choose the band in Mode section and then click OK to complete band setup Amplifier Settings PAI PA2 VSWR Lirnit 3 0 Temp Limit 58 0 o Channel Narrowband Broadband Others Vest Mode Section for Frequency Band Choice File Manage OK cancel 7OOMHz Upper Band oS 700MHz Lower Band W S OOQH fOOL 3 2 9 2 Band setup for JCIMA 1921 P2 e Press the CONFIG softkey in Function Option Section The Global Configuration window will pop up e Choose the band in Mode section and then click OK to complete band setup Global Configuration Amplifier Settings Channel PAT PA2 Narrowband VSWR Limit 3 0 Others Temp Limit 58 0 de Test Mode Section for _ Frequency Band __ gt Broadband Choice Mode File Manage PCS AWS AWS02_ gt PCS PCS PCS01 PCS AWS AWS02 y PCS AWS PCS03 ok canos om Jointcom User Manual Rev 1 02 35 JCIMA P2 Multi function PIM Analyzer lt gt PCS PCS PCSO1 PCS TX PCS TX and measure PIM at PCS RX band lt PCS AWS AWSO2 PCS TX AWS TX and measure PIM at AWS RX band lt PCS AWS PCSO3 PCS TX AWS TX and measure PIM at PCS RX band Note PCS TX 1930MHz 1990MHz PCS RX 1850MHz 1910M
66. int Setup value to compensate external attenuation like cable loss insert loss etc Enable Maximum Hold or Minimum Hold for Test Curve Back to former page of Command Bar Enable the trace to record the test result for further comparison purpose Refresh trace Hold the maximum value for current trace Hold the minimum value for current trace Show the measurement result and trace simultaneously Quickly shift Center Frequency 20 to the lower frequency side Quickly shift Center Frequency 20 to higher frequency side User Manual Rev 1 02 60 JCIMA P2 Multi function PIM Analyzer lt OFFSET OPTION Select Offset curve file to compensate the insertion loss or gain of the Device or System Under test as described in Chapter 5 2 13 lt gt SAVE Save the test result lt gt READ Read the saved test result lt gt SCANTIMES Set up times for scanning the defined spectrum lt CHANNEL POWER Channel Power Measurement lt gt TOP Back to the first page of Command Bar 5 2 Setup for Spectrum Measurement 5 2 1 Test mode setup Press the CONFIG softkey in Function Option Section the Configuration window will pop up as shown in below In Mode area select Narrowband or Broadband and then press OK PIM RTF SPEGTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2019 11 31200 42 l Global Configuration Mode Amplifier Settings PAI PA2 VSWR rnit 3 0 Temp Limit 60 0 E N
67. ion to verify and troubleshooting PIM issues the JCIMA P2 can provide other functions like Range to Fault RTF PIM Fault or VSWR Fault Spectrum Analyzer Isolation Insertion Loss VSWR Return Loss and 2 order Harmonic and 2 order PIM measurements to help the comprehensive evaluation of the quality of passive RF component and antenna feeder system 1 1 JCIMA P2 Models Model Number Frequency Band Tx Band MHz Rx Band MHz 700MHz Band 698 716 JCIMA 700 P2 732 764 Upper and Lower 779 5 804 5 JCIMA 850 P2 850MHz Band 869 894 824 849 JCIMA 900 P2 900MHz Band 930 960 885 915 JCIMA 1800 P2 1800MHz Band 1805 1880 1710 1785 JCIMA 1900 P2 1900MHz Band 1930 1990 1850 1910 1930 1990 JclIMa 1921 p2 1900MHz and AWS and 1710 1910 Dual band 2110 2155 JCIMA 2000 P2 2100MHz Band 2110 2170 1920 2060 JCIMA 2600 P2 2 5GHz Band 2620 2690 2500 2570 Table 1 1 JCIMA P2 Models 1 2 JCIMA P2 Multi function PIM Analyzer Functions PIM Measurement Spectrum Measurement lsolation Insertion Loss Measurement VSWR Return Loss Measurement 2 Harmonic and 2 PIM Measurement support JCIMA 850 P2 and JCIMA 900 P2 only Range to Fault Measurement RTF for PIM Fault and VSWR Fault Respectively Jointcom User Manual Rev 1 02 1 JCIMA P2 Multi function PIM Analyzer 1 3 JCIMA P2 Multi function PIM Analyzer Exterior All external ports of JCIMA P
68. ith date and time automatically when using default name e After the test result being saved successfully the follow window will pop up Press OK button to quit the window J intcom User Manual Rev 1 02 40 JCIMA P2 Multi function PIM Analyzer Saving the C5 File successfully Saving the PDF file successfully Saving the JPG file successfully 3 3 5 2 Read Saved PIM Test Result e Press the READ softkey in the Command Bar SETTING e The Read CSV Report File window will pop up Read Csy Report File f 2009 01 02 19 24 44 csv e Select the file and press OK button to read the saved test result in PIM Measurement Function Window J intcom User Manual Rev 1 02 41 JCIMA P2 Multi function PIM Analyzer 4 Distance to PIM and VSWR RTF The Distance to PIM and VSWR Fault measurement provides the distance measurements for the 3 order PIM and VSWR respectively The distance to PIM and VSWR measurements only work for the linear system Any directional component in the system will impact the measurement results 4 1 Operation Interface To measure the distance to PIM or VSWR press the RTF softkey in the test interface of JCIMA P2 Figure 4 1 shows the RTF operation interface of JCIMA P2 Multifunction PIM Analyzer e PIM RIF SPECTRUM ISOLATION VSWR CONFIG LOCK QUIT 2014 8 26 15 26 42 O VSWR Calibration Data Points 256 Test Setup n AA a Foi rve CabLo
69. lete the set up and close the pop up window Frequency Range Frequency 1369 0 H i 1394 0 869 0MHz 894 0MHz Step 2 0 MHz cane Jointcom User Manual Rev 1 02 83 JCIMA P2 Multi function PIM Analyzer The valid frequency range for VSWR Return Loss measurement is different based on the JCIMA P2 models Table 7 1 shows the detail frequency range for different JCIMA P2 PIM Analyzers Valid Frequency Range MHz JCIMA 700 P2 732 764 Model Number JCIMA 850 P2 869 894 JCIMA 900 P2 930 960 JCIMA 1800 P2 1805 1880 JCIMA 1900 P2 1930 1990 1930 1990 JCIMA 1921 P2 and 2110 2155 JCIMA 2000 P2 2110 2170 JCIMA 2600 P2 2620 2690 Table 7 1 Valid Frequency Range for VSWR Return Loss Measurement 7 2 2 Y Axis Auto Regulation Press the AUTO SCALE softkey in Command Bar the curve display window will regulate itself automatically through adjusting the start and end value of Y Axis for better displaying The value of Y Axis will start from the minimum current measured result and end at the maximum result PIM RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 201311 8 1 46 20 Carrier Freqency MHz FREQ AUTO RANGE SCALE SAVE READ SETTING Jointcom User Manual Rev 1 02 84 JCIMA P2 Multi function PIM Analyzer 7 2 3 VSWR Return Loss Setting Window The Setting window is for calibration and parameter setup for VSWR Return Loss me
70. ll But more sweep time requires longer PIM measurement time The maximum sweep time is 100 times Sweep limes 3 2 3 RF Carriers Parameter Setup As shown in Figure 3 8 user can setup RF carrier parameters by changing the default Frequency Power and Step values in F1 and F2 setup section ing SweepType Freq_Sweep F Frequency Option Frequency 869 0 gt 8740 869 0MHz 894 0MH Valid Frequency Range Output Power Option gt 10 0dB8m 43 0dBm Frequency Step Option MHz lt 8940 gt 869 0MHz 894 0MHz 10 0dBm 43 0dBm MHz PIM Order Im3 At 00 dB Default OK Figure 3 8 RF Carriers Setup Section 3 2 3 1 Frequencies Setup User can set the frequency range of each RF carrier by changing the frequency options in F1 and F2 Setup Section Depending on the model of JCIMA P2 the valid frequency ranges as shown in Table 3 1 are different J intcom User Manual Rev 1 02 30 JCIMA P2 Multi function PIM Analyzer Model Number Frequency Range MHz JCIMA 700 P2 732 764 JCIMA 850 P2 869 894 JCIMA 900 P2 930 960 JCIMA 1800 P2 1805 1880 JCIMA 1900 P2 1930 1990 JCIMA 1921 P2 2110 2170 1930 1990 JCIMA 2000 P2 and 2110 2155 JCIMA 2600 P2 2620 2690 Table 3 1 Valid Frequency Range e When under Frequency Sweep Mode Frequency Option for both F1 and F2 has the minimum and maximum frequency setup options SweepType Fre
71. more accurate the PIM measure will But more sweep time requires longer PIM measurement time The maximum sweep time is 100 times Sweep limes 8 2 3 RF Carriers Parameter Setup As shown in 8 5 user can setup RF carrier parameters by changing the default Frequency Power and Step values in F1 and F2 setup section Jointcom User Manual Rev 1 02 94 JCIMA P2 Multi function PIM Analyzer Harmonic SweepTlype Freq_Sweep Time Points 4 Frequency Option J Frequency 1930 0 H 930 0MHz 960 0MHz en Valid Frequency Range 200 10 0dBm 43 0dBm Output Power Option Beh om Valid Power Range Step 5 0 MHz Frequency Step Option Frequency 5H 930 0MHz 960 0MHz Power 20 0 H 10 0dBm 43 0dBm Step 560 MHz HAR2 Settings r PIM2 Settings Min Y 140 dBm Min Y 140 dBm Max Y 60 dBm Max Y 60 dBm Default Cancel Figure 8 5 RF Carriers Setup Section 8 2 3 1 Frequencies Setup User can set the frequency range of each RF carrier by changing the frequency options in F1 and F2 Setup Section Depending on the model of JCIMA P2 the valid frequency ranges as shown in Table 3 1 are different Model Number Frequency Range MHz JCIMA 850 P2 869 894 JCIMA 900 P2 930 960 Table 8 1 Valid Frequency Range e When under Frequency Sweep Mode Frequency Option for both F1 and F2 has the minimum and maximum frequency setup options J intcom User Manu
72. mpletes the Calibration in Test Setup Display Section turns to PTM 2 RTF SPECTRUM TSOLATTON VSWR HARMONIC CONFIG LOCK QUIT 20148 293 25 07 E 12 0dB Div Peak 20 0dBm 0 00m g Calibration Data Points 256 Prop Velocity 0 740 CabLoss dB 100m 0 000 Start Dis 0 9 00m Div Stop Dis 50 0 METER VELOCITY CAL CAL SETTING READ BACK TOP e The 0 meter calibration is mandatory before RTF measurement Without 0 meter calibration the distance to VSWR measurement can t be started Jointcom WRIA User Manual Rev 1 02 53 JCIMA P2 Multi function PIM Analyzer 4 3 2 3 Velocity Factor Calibration When the velocity factor of the RF cable under test is unknown user can measure the velocity factor via velocity factor calibration Connect the RF Out Port of PIM Analyzer to Standard Adapter and then Low PIM Termination via Low PIM test cable as shown in Figure 4 12 RF Cable Under Test Standard Adapter GSN sow Low PM e Termination Figure 4 14 Velocity Factor Calibration Setup Press VELOCITY CAL softkey in RTF Command Bar as shown in Figure 4 4 Input the type and length of the RF cable under test in the pop up window and then press OK button to start the calibration PIM RIF SPECTRUM TSOLATTON VSWR HARMONIC CONFIG COCK QUIT 2013 11 21 14 06 18 Calibration Data Points 256 Prop Velocity 0 710 CabLoss dB 100m Start Dis 0 METER VELOCITY CAL CA
73. navontenwiepeweeaaierseealedsavannvenseessessueontnendonckeaavoqtunseenivivaeess 71 5 2 16 Preparation Of the Measurement ccccseseccccesecccseseescceesececeusecescuecsesesesessusecsssuseesesuesecessuseeseas 71 5 2 17 Start and Stop the Spectrum Measurement seccccceeeseccceesececceseeseceesececeusecessueeessseesecessuseeeeas 71 5 2 18 SAVE and Read the Test Result sco iccmacatarsinuniavisvsinnesinanialesion wasnatselenenaciddastncmobiuctollcadieseavedaiiandsdesientsbentaess 72 5 3 3 1 Save the Spectrum MEAaSUreMe Nt cccccecccsecccesececeeecccescecsscecsuececsuececsuececsuecetsuecessuecesseecesseeceseueceteneceteuecetenecetseeseten 72 5 3 3 2 Read Saved POSE Result ws csicdsdccnticnceceacdeavasaGescvescedcavesatacayseacdecnesddenayesandeduasavenasaeosdanwasataddyasaudeancsdbenaueeasdeawiesGesacesooasiwenras 72 6 ISOLATION INSERTION LOSS MEASUREMENT FUNCTION ccsccsssssccsscssscecccscssccescsssceccescsssesees 73 61 OPERATING INTERFACE seinere cee dicovcotnctaaneasesicuted ceneacten stan cotoctuseactanenscovusasestn EE 73 6 1 1 FUNCTION OPON SECON sccincsineasacnstcestensbonaconsacancessneavevestenstinatventeaiuerenenastinsaueiicouueneosszeuneouneul 74 6 1 2 TOS E CUT VS SOCIO cain ENE E NA IE sene EEE aes E E E E E even 74 6 1 3 CONTI BOT rnea E baie E ETOO AE E OOO T EA 75 6 2 SETUP FOR ISOLATION INSERTION LOSS MEASUREMENT ssscccccsseccccesececcescceceesececeeececeesecessusesesseneceeseess 75 6 2 1 Fregue
74. nction PIM Analyzer e Choose the file format can be multiple logs with different formats e Specify the file name model number modno serial number serno and the tester s name opeor e Press OK button to execute Save command The test result will be saved under D Report har with date and time automatically when using default name e After the test result is saved successfully the follow window will pop up Press OK button to quit the window Saving the T54 File successfully Saving the PDF file successfully Saving the IPG file successfully 8 3 3 1 Read Saved Test Result e Press the READ softkey in the Command Bar e The Read CSV Report File window will pop up 2009 01 02 19 24 44 csv OK Cancel e Select the file and press OK button to read the saved test result J intcom User Manual Rev 1 02 99 JCIMA P2 Multi function PIM Analyzer 9 Others CONFIG amp LOCK 9 1 Configuration Setup The configuration setup is the general setup for Power Amplifier PA alarms Soectrum Modes etc e Press the CONFIG softkey in Function Option Section The Global Configuration window will pop up Amplifier Settings r Made a PAZ Narrowband VSWR Limit 3 0 C Broadband Others Temp Lirnit 60 0 Test Made OK eons File Manage lt PA1 Tab Power Amplifier 1 lt gt PA2 Tab Power Amplifier 2 lt gt VSWR Limit
75. ncy RANGE SCUD carcvecseanecccanateveecestoesdarsveccadseumniioratoveecsatudscarauaseeduarerecene EEEIEE 75 p22 VPS FUL CG OD rctaiseaseevcrctconesncctanaatewaaa ea sceadion cds eastaesugentedsseancudanebcantewcesedahsensadunuaavaneeevers 76 6 2 3 Isolation Insertion LOSS Setting WINKOW cccccccceseeeeeeeesseeccccccscscccseeseuuueeeseeeseceseeeesseseseeasanaens 77 6 3 ISOLATION INSERTION LOSS MEASUREMENT sscccccssececcesececcessceccesececeusececeessceceesesecsusesecsueseeeueceeeaneesenen 77 6 3 1 Calibration before Medsurement eserine nirereseta ensen TEEN EES 77 6 3 2 Start and Stop the Isolation Insertion Loss Measurement cccccccccccsseeeseeccsccscseeeeeeecssssssunesssss 78 e ie P A ae E T S PEA PES EAE EEAS A A A T AE E A P A AN ASAA IAE E PI E 78 6 3 2 2 Start and St p the Measurement caccisactsntisdosasesiasasdadstoanses lt doiandisboanwesienladalveaaasadstidapaisbheages aaaea 79 65633 Save ONG Read the TCS URS OIE erriren iE eE EEEE O EEA N E 79 ee tee Eae NE Te REU erea E E eee eee N 79 6 3 3 2 Read Saved Test Result cccccssecccesecccesecccesceceecetseeceteecstenecetauecesauecetsneceeegecetsuececseecessuececsuecetsgecetegecetseecetanecetegecetas 80 Jointcom JCIMA P2 Multi function PIM Analyzer 7 VSWR RETURN LOSS MEASUREMENT cccccsscsscsscssccccccccsccsccsccsccssccccsccsccsscsccscesscscessessessessesceess 81 74 OPERATING INTERFACE icatssre srs vars renn EEE EREE 81 7 1 1 FUNCTHOM ODUON S CUO
76. ntcom User Manual Rev 1 02 91 JCIMA P2 Multi function PIM Analyzer 8 1 3 Command Bar Press the softkeys in Command Bar for 2 Harmonic 2 Order PIM test setup and measurement START SAVE READ SETTING lt gt START Start and Stop the 2 Harmonic measurement lt PEAK Mark the Peak test point from the measurement result lt gt REV Reverse 2 Harmonic and 2 Order PIM Measurement lt gt FWD Forward 2 Harmonic and 2 Order PIM Measurement lt gt SAVE Save test result lt gt READ Read saved test result lt Setting Open the setup window 8 1 4 Test Result Evaluation Section There are 2 parts in Test Result Evaluation Section Peak PIM and Pass Fail Limits and Evaluation Evaluation 80 Pass Fail limit dEc De Figure 8 3 2 Harmonic 2 PimTest Result Evaluation Section lt Pass Fail Limits and Evaluation Setup Pass Fail limit and Provide Pass Fail Result Jointcom User Manual Rev 1 02 92 JCIMA P2 Multi function PIM Analyzer Double Press the area to get the pass fail limit setup popup window in the right 8 2 Setup for 2 Harmonic 2 PIM Measurement Press the SETTING softkey in the Command Bar as shown in below START SAVE SETTING The Setting Window as shown in Figure 3 7 will pop up The Setting window is for setup of PIM measurement All standard PIM measurement setup is set as default by manufacture Press the Default button in th
77. o normal e Wait until measurement complete or press START button again to stop the measurement READ SETTING While the remote display reports the Isolation Insertion Loss measurement result the Peak Isolation Insertion Loss result is also displayed in the LED screen of PIM Analyzer front panel 6 3 3 Save and Read the Test Result 6 3 3 1 Save the Test Result e Press the SAVE softkey in Command Bar e The save setup window will pop up J intcom User Manual Rev 1 02 79 JCIMA P2 Multi function PIM Analyzer Save Path d reportiiso Change Menu File Type r File Name V CSV 2013 11 05 15 45 06 JPG 2013 11 05 15 45 06 PDF 2013 11 05 15 45 06 modno here is no model no OK serno here is no serial no opeor default user Cancel e Choose the file format can be multiple logs with different formats e Specify the file name model number modno serial number serno and the tester s name opeor e Press OK button to execute Save command The test result will be saved under D Report iso with date and time automatically when using default name e After the test result is saved successfully the follow window will pop up Press OK button to quit the window Saving the T54 File successfully Saving the PDF file successfully Saving the IPG file successfully 6 3 3 2 Read Saved Test Result e Press t
78. o VSWR e When using remote control terminal please confirm only WiFi LED in PIM Analyzer front panel is on Red and the LED screen shows 1111 J intcom User Manual Rev 1 02 50 JCIMA P2 Multi function PIM Analyzer 4 3 2 Calibration for Distance to PIM Fault Measurement 4 3 2 1 0 Meter Calibration for RTF Test Mode e Connect the RF Out Port of PIM Analyzer to Standard Adapter and then Low PIM Termination via Low PIM test cable as shown in Figure 4 12 50W Low PIM Termination Figure 4 12 0 Meter Calibration Setup for distance to PIM e Press O METER CAL softkey in RTF Command Bar as shown in Figure 4 4 e Input the value marked in the Standard Adapter to the pop up window as shown in Chapter 4 2 5 1 and then press OK button to start the calibration e During the Calibration the Calibration in Test Setup Display Section shows OFF and the system shows the calibration status at the top right corner of the Test Curve Section First Calibration then Second Calibration PIM 2 RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2014 8 29 2 38 22 10 0dB Diy CabLoss dB 100m 100 0 O METER VELOCITY CAL CAL SETTING SAVE TOP Jointcom User Manual Rev 1 02 51 JCIMA P2 Multi function PIM Analyzer PIM 2 RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2014 8 29 2 40 04 10 0dB Diy 9 VSWR Calibration Data Points 256 Pr
79. o normal after the meaurement is completed or stopped 4 3 4 Distance to PIM and VSWR Test Result After completing the distance to PIM or VSWR measurement the test result will be shown with both test curve and Peak PIM or VSWR with distance at the top of Test Curve Section Jointcom User Manual Rev 1 02 55 JCIMA P2 Multi function PIM Analyzer PTM 2 RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2014 8 29 2 5451 H e n EEE Peak 70 6dBm 4 10m Peak PIM iia Calibration Data Points 256 Prop Velocity 100 0 0 000 Marker Peak PIM Stop Dis 50 Start Dis 0 5 00m Div SET START POWER PEAK RESOLUT TON DISTANCE LAST NEXT SPECTRUM ISOLATION VSWR HARMONIC CONF TG LOCK QUIT 2014 8 29 3 28 29 Distance to Peak VSWR 12 44 2 93m Peak VSWR TE RTF SSe Calibration Data Points 256 Prop Velocity j FARS a 0 740 C apa eee A lan fc CabLoss q urve dB 100m 720 y Marker Peak VSWR 5 00m Div Stop Dis 50 Start Dis 0 SET START POWER PEAK RESOLUT TON DISTANCE LAST NEXT 4 3 5 Save and Read RTF Test Result 4 3 5 1 Save the Test Result e Press the SAVE softkey in Command Bar e The save setup window will pop up Jointcom User Manual Rev 1 02 56 JCIMA P2 Multi function PIM Analyzer File Type File Name M CSV 2009 01 02 08 44 56 OK M JPG 2009 01 02 08 44 56 Cancel e Choose the file format can be multiple logs with different fo
80. o turn off the PIM Analyzer Please refer Chapter 2 3 for detail Turn off steps 10 Switch off the 220V 110VAC to 48VDC Adapter and unplug the power cord from the source outlet All RF Connectors Adapters Terminations and the cable accessories are easily worn out parts Proper protection such as carefully handling use of protection lids storing them in the original protection case etc can extend the life cycle of these parts 2 2 Setup and Operation of Wireless Remote Control JCMIA P2 supports wireless point to point remote control Any Windows XP Windows 7 Android 2 2 or above or iPhone iOS based PC Tablet or Smart Phone with WiFi support can be used as the remote control terminal 2 2 1 Setup Remote Control Window for Windows System JCIMA P2 supports Windows XP SP3 and Windows 7 SP1 system e Open the Network Connection window by click aiil sign at the right bottom corner of the Windows GUI Choose the JCIMA P2 connection Dxxxxxxxxxxx DxxxxxXxXXXXxXx is the serial number of the PIM Analyzer and then Click Connect Unidentified network No network access Dial up and VPN DUNI Wireless Network Connection FI Information sent over this network might be visible to others J intcom User Manual Rev 1 02 9 JCIMA P2 Multi function PIM Analyzer e Confirm JCIMA P2 is connected as shown in figure below Currently connected to Unidentified network j No network access
81. ode section to setup the measurement mode as shown in Figure 4 5 PIM RTF SPECTRUM ISOLATION VSWR CONFIG LOCK QUIT 2014 8 26 15 26 42 Test Mode Section Calibration Data Points 256 SET START DISTANCE POWER PEAK RESOLUT TON Choice of a es Choice of est Moae distance to VSWR Test Mode Figure 4 5 0 Test Mode Setup for RTF Function Jointcom User Manual Rev 1 02 45 JCIMA P2 Multi function PIM Analyzer 4 2 2 Setup for Power Level Press the Power softkey in the Command Bar The Power window will pop up as shown in below TE 43 00 33 0dBrr 43 0dBm cane e The TX frequency range for F and 3 Order PIM frequency are shown in Table 4 1 e The Tx is for transmission power setup The power range is from 33dBm to 43dBm TX Frequency 3 order PIM Range MHz Frequency Range 698 716 779 5 804 5 JCIMA 850 P2 869 894 824 849 JCIMA 900 P2 930 960 885 915 JCIMA 1800 P2 1805 1880 1710 1785 Spectrum JCIMA 700 P2 732 764 JCIMA 1900 P2 1930 1990 1850 1910 1930 1990 JCIMA 1921 P2 and 1710 1910 2110 2155 JCIMA 2000 P2 2110 2170 1920 2060 JCIMA 2600 P2 2620 2690 2500 2570 Table 4 1 TX Frequency and 3 Order PIM Frequency Range for RTF 4 2 3 Setup for Resolution Press RESOLUTION softkey in Command Bar to set up the number of test points for RTF measurement RESOLUT 1 ON Jointcom
82. onfiguration and frequency band for Dual band Model only setup lt LOCK Screen Lock Setup lt gt QUIT Quit Test Window to Windows Interface 3 1 2 Test Curve Section Figure 3 2 shows the PIM measurement result with test result curves 100 0 E Y Axis PIM dBm dBc 140 0 1680 0 180 0 Threshold Line Marker X Axis Test Result Curves Frequency or Times Red and Yellow Lines Figure 3 2 PIM Test Curve Section lt gt Test Curves Yellow curve shows Frequency Time Sweep PIM measurement when F1 sweeps Red curve shows Frequency Time Sweep PIM measurement when F2 sweeps The number of test points can be defined by user as described in Chapter 3 2 lt gt Marker Mark the test point or peak point to show the test result with detail value lt gt X Axis Show the current test mode Depending on frequency or time sweep modes user chooses it will show detailed frequencies or times lt Y Axis Show the PIM Level lt gt Threshold Line Pass Fail Criteria line which is defined by user as described in Chapter 3 1 3 3 1 3 Test Result Evaluation Section There are 2 parts in Test Result Evaluation Section Peak PIM and Pass Fail Limits and Evaluation Jointcom User Manual Rev 1 02 25 JCIMA P2 Multi function PIM Analyzer peakrim LJ Pass Fail Limits and Pass Fail limit dBc ass Fail Limits an B Evaluation OEE Figure 3 3 PIM Test Result Evaluation Section lt gt Peak PIM Show the
83. op Velocity CabLoss dB 100m 0 000 Start Dis 0 O METER E SETTING SAVE READ TOP CAL e The 0 meter calibration is mandatory before RTF measurement Without 0 meter calibration the distance to PIM measurement can t be started 4 3 2 2 0 Meter Calibration for VSWR Test Mode e Connect the RF Out Port of PIM Analyzer to Standard Adapter and then Low PIM Termination via Low PIM test cable as shown in Figure 4 13 INPUT OUTPUT Port Port Short Circuit Coupling Port Figure 4 13 0 Meter Calibration Setup for distance to VSWR e Press O METER CAL softkey in RTF Command Bar as shown in Figure 4 4 e Input the value marked in the Standard Adapter to the pop up window as shown in Chapter 4 2 5 2 and then press OK button to start the calibration e During the Calibration the Calibration in Test Setup Display Section shows OFF and the system shows the calibration status at the top right corner of the Test Curve Section First Calibration then Second Calibration Jointcom User Manual Rev 1 02 52 JCIMA P2 Multi function PIM Analyzer PTM 2 RIF SPECTRUM TSOLATTON VSWR HARMONTC CONFIG LOCK QUIT 2014 8 29 3 23 53 12 0dBiDiv Peak 20 0dBm 0 00m Peak 20 OdBm 0 OC Mode q Calibration Data Points 256 Prop Velocity 0 740 CabLoss dB 100m 0 000 Start Dis 0 5 00m Div Stop Dis 50 0 Er ET SETTING SAVE READ BACK TOP 1 e After Calibration co
84. ost exe svchost exe svchost exe svchost exe svchost exe Isass exe services exe winlogon exe jcPimSoftware exe csrss exe smss exe tIntsvr exe Administrator Administrator Administrator SYSTEM Administrator LOCAL SERVICE NETWORK SERVICE SYSTEM NETWORK SERVICE SYSTEM SYSTEM SYSTEM SYSTEM Administrator SYSTEM SYSTEM SYSTEM Show processes From all users O 2 472K 3 612 K 3 980 K 5 264 K 13 228 K 4 620 K 3 048 K 14 584 K 4 276 K 5 192 K 1 108 K 8 364 K 4 640 K 24 176 K 3 844 K 396K 4 000K End Process 848 16 649 6 NO F1 dBm Jointcom F1 MHz ELE s MMS IMS 1M7 IMO P2 dBm F2 MHz Im3_F MHz Im3_V dBm User Manual Rev 1 02 Power 0 0 dBm Pass Fail limit dBm 20 dBm dBc MaxPIM 0 0 MinPIM 0 0 AvgPIM 0 0 dBm dBm dBm Temp VSWR Enter Peak 0 0 dBm Pass Fail limit dBm 320 MaxPIM 0 0 MinPIM 0 0 AvgPIM 0 0 dBc dBm dBm dBm Power Temp YSWR SETTING JCIMA P2 Multi function PIM Analyzer E windows Task Manager Eo er suo h VSWR HARMONIC CONFIG LOCK QUIT 201911 1115125 Applications Proces 7274 By a Peak S YCHOST EXE Off Administrator 2 764 K ctfmon exe Administrator oo 3 612 K rdpclip exe Administrator 00 4 088 K spoolsv exe SYSTEM oo 5 244 K mspaint exe Administrator 00 1 352 K explorer exe Administrator 00 13 768 K svchost
85. p fail or no response after 70s a FO System Boot up successful 000 0 VSWR Measurement Test Result of Peak VSWR or Return Loss The Unit is dB for Return Loss Isolation Measurement Test Result of Peak Isolation Insertion Loss The Unit is dBc PIM Measurement Test Result of Peak PIM The Unit is dBc Other Measurements 1111 For Spectrum 2 Harmonics and Range to Fault measurement In Windows Interface p When system is in windows interface or under preheat process Blinking 0000 Waiting for Response Test in process ED No Response E001 Spectrum Analyzer self check failure Test Completes with problems u E002 Power Amplifier self check failure J intcom E003 User Manual Rev 1 02 PA VSWR Alarm 22 E004 JCIMA P2 Multi function PIM Analyzer PA Over Current Alarm E005 PA Over Temperature Alarm E006 PA Low Power Alarm E007 PA High Power Alarm E008 Test incomplete Alarm Turn Off the PIM Analyzer yy Turn Off Counting Time Turn Off Fails Jointcom LF 1 User Manual Rev 1 02 23 JCIMA P2 Multi function PIM Analyzer 3 PIM Measurement Function The PIM measurement function provides the measurement for 3 order 5 order 7 order and 9 order of p
86. pdesktop com forums 152996 Guides Jointcom Ur User Manual Rev 1 02 14 JCIMA P2 Multi function PIM Analyzer 2 2 3 Remotely Control the PIM Analyzer 2 2 3 1 Access Test Window of PIM Analyzer For Windows operation system please follow steps as described in Chapter 2 2 1 to access the PIM Test Window For Android based systems double pressing the icon the Jump window will show in the terminal screen Press the display name to get access to the PIM Analyzer test window Winooms emote Cesktog When getting access to the test window all measurements can be used based on the measurement steps defined by Chapter 3 to Chapter 8 PIM RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT 2013 10 25 23 20 07 o Pass Fail limit dBc 848 16 849 6 aks V F1 F2 Freq MHz Time s IMS IMS 1M7 IM9 dBc NO P1 dBm Fl MHz P2 dBm F2 MHz Im3_F MHz Im3_ dBc 844 0 1 846 0 174 5 848 0 Power Temp YSWR 43 1 23 5 SETTING 2 2 3 2 Soft Keyboards When using remote control desktop there are 2 soft keyboards which can be used for data input Both soft keyboards can work independently 1 Soft Keyboard with PIM Analyzer Jointcom User Manual Rev 1 02 JCIMA P2 Multi function PIM Analyzer Double press the data input area for any data input field and press the number to input data in the pop up soft keyboard Pass Fail limit dBm Double Press the area to get the pass fa
87. q_Sweep S 8740 gt 869 0MHz 894 OMHZz 10 0dBm 43 0dBm lt 10 0dBm 43 0dBm MHz PIM Order Im3 Atti 00 dB Count owen C e When under Time Sweep Mode only Minimum Frequency is available in Frequency Option area the gray areas are not selectable J intcom User Manual Rev 1 02 31 JCIMA P2 Multi function PIM Analyzer FY Frequency 869 0 Power 43 0 Step F2 Frequency Power 43 0 Step PIM Order Im3 3 2 3 2 Power Setup 7 SweepTimes 10 3 10 09Bm 43 8940 gt 869 0MHz 3894 OMHz 10 08 43 0dBm In the Output Power Option Section as shown in Figure 3 8 user can define customized carrier output power level The valid output power range is from 10dBm to 43dBm The minimum power step is 0 1dB 3 2 3 3 Frequency Step Setup The Frequency Step is used to setup the frequency sweep step when using Frequency Sweep Mode User can customizes the frequency step via changing the setting in Frequency Step Option Section which is shown in Figure 3 8 The minimum frequency step is 0 1MHz When under time sweep mode this option is not available and the selection area will turn gray 3 2 4 Setup for PIM Orders For different scenarios 3 Order PIM is not necessary the major reason causing the Wireless System performance issue The 5 7 or even 9 PIM Orders could cause issues as well JCIMA P2 Multi function PIM Analyzer allows user to measure different orders of PIM Produc
88. rement and the measured level for a given point in time e The HOLD softkey is used for evaluating fluctuations in the measured levels WA Current measurement K SSS Se Center 900 000MHz N A measured level Span 0 150MHz TRACE s9 OFFSET SELECT REFRESH MAXHOLD MINHOCD ROED OPTION BACK NEXT lt Clear a trace press the REFRESH softkey to clear an active trace lt Turn off trace To turn off trace use either of the following methods e Press the TRACE SELECT softkey and then in the displayed list press the trace number you want to disable e Press the MAXHOLD MINHOLD or HOLD softkey which is currently turned on to turn it off e Press the TRACE SELECT softkey and then press the ALL OFF button All the displayed traces will be turned off ALL OFF TRACE TRACES TRACES IRoOCE TRACES TRACE SELECT Jointcom User Manual Rev 1 02 68 JCIMA P2 Multi function PIM Analyzer 5 2 12 Quick Span Shift Command Press the lt lt softkey in the Command Bar to quickly shift 20 of Center Frequency to lower side Press the gt gt softkey in the Command Bar to quickly shift 20 of Center Frequency to higher side TRACE REFRESH MAXHOLD MINHOLD HOLD lt lt gt SPT ON BACK NEXT SELECT 5 2 13 Load Offset File for Compensation JCIMA P2 Spectrum Analyzer function allows user to import an offset curve file which has the attenuation value
89. rmats e Specify the file name then press OK button to execute Save command The test result will be saved under D Report rtf with date and time automatically when using default name e After the test result is saved successfully the follow window will pop up Press OK button to quit the window Saving the C5 File successfully Saving the JPG file successfully 4 3 5 2 Read Saved Test Result e Press the READ softkey in the Command Bar e The Read CSV Report File window will pop up Read Csy Report File 2009 01 02 19 24 44 csy OK Cancel e Select the file and Press OK button to read the saved test result Jointcom User Manual Rev 1 02 JCIMA P2 Multi function PIM Analyzer 5 Spectrum Analyzer The JCIMA P2 supports Spectrum Analyzer function which can provide the spectrum measurement During the test this feature can be used for specific spectrum scan carrier power or RF environment emission scan The detail specification of the Spectrum Analyzer function is shown as below lt Frequency Range 100MHz 3GHz lt gt Noise Floor 135dBm 1KHz Receiving Band 120dBm 1KHz Wide band lt gt Resolution Band Width 1KHz 10KHz 100KHz lt Dynamic Range 70dB lt gt Attenuation 0 10 20 30 40dB lt Amplitude precision 1 dB Ea Frequency Precision 2ppm 5 1 Operation Interface To use the spectrum analyzer function press the SPECT
90. rt Defaut OOK Cancel Figure 6 3 Setting Window for Isolation Insertion Loss Feature lt gt Tx dBm RF Transmission Power for the measurement 10 30dBm lt gt ATT Internal attenuation for receive spectrum analyzer 0 40dB gt MinY The start dB value of the Y Axis lt Max The stop of the Y axis lt gt Limit dB Limit line setup for the test lt Rev Setup compensation value dB for extra insertion loss e g Cable loss etc lt gt Calibration For Calibration before measurement lt Default Set all parameters back to manufacture setting 6 3 Isolation Insertion Loss Measurement 6 3 1 Calibration before Measurement e Connect the PIM Analyzer for calibration setup as shown in Figure 6 4 N DIN Connector Test Cables WSs ahah Attenuators Connector Provide by manufacturer Figure 6 4 Setup for Isolation Insertion Loss Calibration Jointcom User Manual Rev 1 02 77 JCIMA P2 Multi function PIM Analyzer Please use the torque wrench to ensure the accuracy of measurement results Recommended torque 5N M for N type connector 17 5 22N M for 7 16 type connector e Press ISOLATION softkey in Function Option Section to access the Isolation Insertion Loss operation interface e When using remote control terminal please confirm the WiFi and ISO LEDs in PIM Analyzer front panel are on Red BEE e Confirm the broadband connector N Type Connector of JCIMA P2 is
91. s 88 Poe Save the Test ResUl inanccctacesavactoucnaaacecasaweuccusataacdnvaqetawandesancuudebeudasdtecndaveoheanavaraennauasibawandeashwasecnueceuseacesssacttnssvabauencuauntets 88 7 3 3 2 Read Saved Test RS SIAM econ carscacencoretsraseceinrcaeneatttcmancaen a eanotesiciroricainaeatesns Sa aanak anien Eara donas gus etuasoiniceniiatn etesantecanneauaeeunaobes 89 8 2 HARMONIC AND 2 ORDER PIM MEASUREMENT FUNCTION ccccssscscsssccssscsessscssssesesseesseee 90 SA OPE RATING VINTEC essere cette ceed cis ecet scteeecoset A 90 8 1 1 F ncUon OPTION SECC recreere ao enea E E E E E ORES 90 8 1 2 CUE SOC O eoa E RE EEE EEE E E ENEE ENE EERS 90 8 1 3 maA B ean E E eaeeneee es seaees eee 92 8 1 4 TEST Result Eval ation SCCTON scsccscecastsscesenssethonnssesen chbcateeanscedeecubscdbeanbontencbbceieeanncesecanecedbeapocnsesds 92 8 2 SETUP FOR 2 HARMONIC 2 PIM MEASUREMENT ccccccecescccceesccccescccsestccceesceceesceceesceeeeteesetaceeeeateess 93 8 2 1 TOS MOA SC a E E E E TETE E E I TE O 94 Bee A FRC OUST Weep MOUE noore A EET 94 8 2 1 2 Time Sweep MOE 2 cccceecccesecccesececeecccaececsuececsuecetsuececauececauececaueceteuececauecetanecetseecetsnecetsucetauecetsuecetseecetsuecetsuecetsnecetees 94 eA LSe Up TeSt MORE cernes A a EEE a AEE AAA 94 g2 SWEEP TIMES SOUD ivori tsi srira PEE ENNE EERE EERE EAN INN E OEE 94 8 2 3 RF Carmer Parameter SetU ussite sun aera nenn ETA EEA E REEE E 94 8 2 3 1 Frequencies Setup essesss
92. ss dB 100m SET Command Bar C START POWER PEAK RESOLUTION DISTANCE NEXT Figure 4 1 RTF Operation Interface 4 1 1 Function Option Section Please refer Chapter 3 1 1 for Function Option Section 4 1 2 Test Setup Display Section The test setup display Section shows the detail setup parameter for the distance to PIM or VSWR measurements Please refer Section 4 2 for the detail test parameter setup Jointcom User Manual Rev 1 02 42 JCIMA P2 Multi function PIM Analyzer 4 1 3 Test Curve Section As shown in Figure 4 2 and 4 3 the RTF Test Curve Section shows the distance to PIM and VSWR measurement results respectively Distance to PIM Y Axis PIM dBm Marker Threshold Line Bails Test Curve Distance m Figure 4 2 RTF PIM Test Curve Section lt Test Curve Yellow curve shows the distance to PIM measurement result lt gt Marker Mark the peak PIM fault which exceeds the threshold lt gt X Axis Show the distance in meters lt Y Axis Show the PIM Level in dBm lt Threshold Line Pass Fail Criteria line which is defined by user Jointcom User Manual Rev 1 02 43 JCIMA P2 Multi function PIM Analyzer Distance to VSWR Marker X Axis Test Curve Distance m Figure 4 3 RTF VSWR Test Curve Section lt Test Curve Yellow curve shows the distance to VSWR measurement result lt gt Marker Mark the peak VSWR lt X Axis Show the distance in meters lt Y Axis Show the VSWR Lev
93. ssessesresresrrsrrsrrsrrsersrrsrrsrrstvstrtstottsttstts testes trs tets tserte PrE OPEC rESEES EESE ESEESE Sense rs resenseer reoreoreoreorenteo 95 OA LFO T OU E EE EE E A EE E OAE EEE AEA 96 EAA AE S E E 210 0 o P A ne eer AE T EAT EA ere eee oer AE TT IE A A TT 97 8 2 3 4 Set p the Max Min value OF Y AXIS se sciccacsncnevocstocccnconsnewasenodocncbnswesocstndocnennsunesesbodocadbnaueubosbodosmennsunesasbodowmcnmouodbesbodownaenoas 97 8 3 2 HARMONIC 2 ORDER PIM MEASUREMENT csccccesccccceccececsccecesccceescccsestecceessecsenseeeeeaceeeeseceetateeeeaueens 97 8 3 1 Preparation Before the measurement sseseccceseecccueseccceesecsesesecsssuseeseceuseceseusecsssuesesssuesesessees 97 8 3 2 Start and Stop the 2 Harmonic 2 Order PIM Measurement ccccccccccceseeeseccccscscsueeeeeceesssseuns 98 8 3 3 Save and Read the Test Res Crp cies cencceceancccmucdeuesuscocticnxtenvabnsiaed oes Wensenisecdennvidexcerstacaodestiacsesteaest 98 8 2 6 1 Save the Test RESuIt ccccccccccccsecccessceuccceucccesseueseeuseuuuseueseeucseeussueuseueseeusseeuseeeseueseeuseeeuceueseeueeeeuseeeuseueseenseueuseueesss 98 8 3 3 1 Reat Saved Test PS as ces eacesrarecarenaen vives concn EE E Ar A EAE 99 9 OTHERS CONFIG amp LOCK sessssssesesssssssossssesssssssososcsessososososossososososessososososossssosososossososososessssososo 100 eds CONFIGURATION SETUP ceoencdterepesiesaibeosiaevionanieg vonseuaenesacleceabe sauneanacn citea ncaa ene anpanad obvsasansene
94. t As shown in Figure 3 9 user can setup the PIM Order options for measurement of different PIM orders Jointcom User Manual Rev 1 02 32 JCIMA P2 Multi function PIM Analyzer SweepType Freq_Sweep v SweepTimes 1 0 F1 Frequency 869 0 gt 874 0 gt 869 0MHz 894 0MHz Power 43 0 10 0dBm 43 0dBm Step 1 0 MHz F2 Frequency 884 0 i 894 0 gt 869 0MHz 894 0MHz Power 43 0 10 0dBm 43 0dBm Step 1 0 MHz PIM Order Im3 Att 0 0 2 dB Count Defautt f ok Choice for 3 5 D gt 7 or 9 orders of PIM Figure 3 9 Setup for PIM Orders After choosing the PIM orders the frequency option will set back the manufacture defaultv alues automatically The default frequency ranges for different orders are different Formula for PIM Orders IM3 2 F1 F2 or 2 F2 F1 IM5 3 F1 2 F2 or 3 F2 2 F1 IM7 4 F1 3 F2or4 F2 3 F1 IM9 5 F1 4 F2or5 F2 4 F1 3 2 5 Attenuation Setup The attenuation setup is the attenuation level set for the internal spectrum analyzer This feature is normally used for manufacture calibration The default value 0 0 is not suggested to be changed Att 0 0 dB 3 2 6 Count Setup The count option as shown in Figure 3 10 is for Time Sweep Test Mode only will turn gray for non selectable under Frequency Sweep Mode The Count option is to set the PIM test points 1 second per test point for each time sweep cycle Join
95. t is a Safety Class product When supplying power to this equipment connect the accessory 3 pin power cord to a 3 pin grounded power outlet If a grounded 3 pin outlet is not available use a conversion adapter and ground the green wire or connect the frame ground on the rear panel of the equipment to ground If power is supplied without grounding the equipment there is a risk of receiving a severe or fatal electric shock AN Only the AC DC power adaptor supplied by Jointcom should be used Jointcom is not liable for any personal injury or product damage caused by using non standard power supply equipment covers or to disassemble internal components Only certified service technicians This equipment may not be repaired by the operator Do not attempt to remove the with the knowledge of electrical fire and shock hazards should service this equipment There are high voltage parts in this equipment presenting a risk of severe injury or fatal electric shock to untrained personnel In addition there is a risk of damage to precision components Input Power amp Other Information The input voltage for PIM Analyzer is 48VDC 15 The allowable line input voltage for AC DC Adapter is 220VAC 110VAC 10 Table I Input Power Requirements Item Specification Regulated Input 220VAC 110VAC 10 50 60 Hz JCIMA P2 Instrument Power Consumption 300W Caution 1 The Power Amplifier and Signal Source should not be turned on w
96. taiaeunedecieusaaeaeson 100 Ie SOR BEN EOCK FRING TION oreren sacescs son secasniaeieesoonnisescensines boatennaanuesupssennancinesnuaes bea nonceaeeeoens 100 APPENDIX A PRODUCT SPECIFICATIONS scsicsscacsicssuscsccassxcinnncavisxeisecwscapsnesssavnencnucssinssbcsssnsevcnesesaxeueexeine 102 Jointcom VI JCIMA P2 Multi function PIM Analyzer APPENDIX B MAINTENANCE AND TIPS wisssssssasssnsesnsnanedsstnantindsvassanoswanswagennusanasennteansnsiiespiaentdegeneeseusseaes 104 CONTACTS sxiccssesncaannss sisinsdiran eara eiia E a aaea 105 Table of Figure PEO VL FON VION e E EEE E EEEE E EEE 2 Fere TA BE VIEW e E EE E E E E E 2 Foue oL SIC OW a E A E E E AE 3 AU ig aves Ror REM dE VIEW aaa E E E E E EE eee 3 Pie 2 1ICIMA P2 Front Pane eet ccs ators cae Seen e i a AE T AEE E EEEE TET 20 Fig re 3 1 PIM Op ration ile fa E ocsscccscacasondesasesreacensesdsesasestunsanande scosanaabaasaadtsoosashepsesatdeseoasransendssdesonsatendaconss 24 Fig re 3 2 PIM Test Curve Secon enarrare E E E 25 Figure 3 3 PIM Test Result Evaluation Section cccccseccccsssssccsnscccecnesscecessscseenssesecuesscecessseseeueseseeuessesees 26 Figure 3 4 PIM Test Mode Display Section ivccicsseccsvesinesseticeveincestensvlibevaiseoswecontneavoduenedeseelsbavesoesisecenlbssselovestewade 26 Figure 3 5 PIM Test Report SCHON suse scsnceissoidanse n E REES 27 Heure oG PIM Command BN se cee Sasa cesses teases oanccst acco ASe ERA aa van dae ae Erre EREN 28 Figure 3 7
97. tcom User Manual Rev 1 02 33 JCIMA P2 Multi function PIM Analyzer SweepType LOE Sweeptimes 10 F Frequency 869 0 869 0MHZ 894 OMHz Power 43 0 10 Od8m 43 0dBm Step F2 Frequency Power 43 0 Step PIM Order Im3 Figure 3 10 Count Option 3 2 7 Power Range and Power Step Setup When under Power Sweep mode the Power Range and Power Step can be set as shown in Figure 3 11 SweepTimes 5 0 F Start Power Level Frequency 869 0 869 0MHz 894 0MHz 1 10 0dBm 43 0dBm x Stop Power _ alee Power Step Frequency 894 0 869 0MHz 894 0MHz Power 30 0 lt gt 43 0 10 0dBm 43 0dBm Power Step 1 0 4 dB PIM Order IM3 Att 0 0 dB Count Default OK Cancel Figure 3 11 Count Option 3 2 8 Save or Set Back Default Setting After setup press OK button at the bottom of the setting window System will save the setting and close the Setting Window automatically When user wants to get back the default setup press the Default button at the bottom of the Setting Window All parameters will set back to the default value J intcom User Manual Rev 1 02 34 JCIMA P2 Multi function PIM Analyzer 3 2 9 Frequency Band setup for Dual band Model only For Dual band PIM Analyzers depends on the frequency band which user wants to test user needs to define the band from changing the band setup under CONFIG function option w
98. tion Measurement Function essssessssesrressrresesrcressreresrreeerereerrrreseeees 73 Figure 6 2 Isolation Test Curve Section cccccccecccccesscccceesecccceecceceusececsuecsssuecceseusecsesunecsesuusesessueecesseeseeeees 74 Figure 6 3 Setting Window for Isolation Insertion LOSS Feature cccccccccccccccccccceseseeeeeeesseeeeeeeeesesseeeeeeeas 71 Figure 6 4 Setup for Isolation Insertion Loss Calibration sseesessssssssseeeersssssesssssssssseeerrrrrrreeeesssssessseeererrree 77 Figure 6 5 Setup for Isolation Measurement cecccccessecccceecceceusececeuseccscueccesuuececsuecessuneecesaueecessueeeseees 79 Figure 6 6 Setup for Insertion LOSS Measurement ccccccsssccccesecccceseceeceeecceceuseceseueecssseueecesseecessueeeeeees 79 Figure 7 1 Operation Interface of VSWR Return Loss Measurement FUNCTION 0 cccccceeeeeeeeeeeeeeeeeeees 81 Figure 7 2 VSWR Return Loss Test Curve Section cccccccccccccccceeeeeeeeeesescecccccccssssseeeeeeueeesssseeeeesesesssseeeeeeeas 82 Figure 7 3 Setting Window for VSWR Return LOSS Feature eesessssssssseeeersssssesssssssssseertrrrrrreeeessssssssseeeerrreee 85 Figure 7 4 Setup for VSWR Return Loss Calibration eseseessessessesssssssseererrrrrsssessssssssseeettrrrrrreesssssssssseeeeerrree 86 Figure 7 5 Setup for VSWR Return Loss Measurement eeesssssssssssssssrrrrrrresesssssssssserettrrrrrreeesssssssesseeeeerrree 88 Figure 8 1 Operation Interface of
99. turn Loss Test Curve Section Jointcom User Manual Rev 1 02 Limit Line Test Curve 82 JCIMA P2 Multi function PIM Analyzer lt gt Test Curve Yellow curve shows the VSWR Return Loss measurement result lt gt Peak Marker Show the peak point in the curve lt Peak Value Show the frequency and VSWR or Return Loss value of peak point lt gt Unit Bar Press to switch between Return Loss and VSWR lt X Axis Frequency lt Y Axis Return Loss Level in dB or VSWR level lt gt TX Power Transmission power of the Power Amplifier lt Limit Line Line of limit which user uses to evaluate test result 7 1 3 Command Bar Press the softkeys in Command Bar for VSWR Return Loss test setup and measurement READ SETTING lt gt START Start and Stop the VSWR Return Loss measurement lt gt FREQ RANGE Frequency range setup for VSWR Return Loss measurement lt gt PEAK Mark the Peak test point from the measurement result lt gt AUTO SCALE Y axis Auto regulation lt gt SAVE Save test result lt gt READ Read saved test result lt Setting Open the setup window 7 2 Setup for VSWR Return Loss Measurement 7 2 1 Frequency Range Setup The frequency range option will allow user to setup the sweep frequency range and step for VSWR Return Loss measurement e Press the FREQ RANGE softkey in the Command Bar e Input the frequency range and step in the pop up window e Press OK button to comp
100. vel in dB lt gt TX Power Transmission power of the Power Amplifier lt Limit Line Line of limit which user uses to evaluate test result Jointcom W User Manual Rev 1 02 74 JCIMA P2 Multi function PIM Analyzer 6 1 3 Command Bar Press the softkeys in Command Bar for Isolation Insertion Loss test setup and measurement SAVE READ SETTING lt gt START Start and Stop the Isolation Insertion Loss measurement lt FREQ RANGE Frequency range setup for Isolation Insertion measurement lt gt PEAK Mark the Peak test point from the measurement result lt AUTO SCALE Y axis Auto regulation lt gt SAVE Save test result lt gt READ Read saved test result lt Setting Open the setup window 6 2 Setup for Isolation Insertion Loss Measurement 6 2 1 Frequency Range Setup The frequency range option will allow user to setup the sweep frequency range and step for isolation insertion loss measurement e Press the FREQ RANGE softkey in the Command Bar e Input the frequency range and step in the pop up window e Press OK button to complete the set up and close the pop up window Frequency Range Frequency 369 0 1894 0 869 0MHz 894 0MHz Step 2 0 MHz cane The valid frequency range for Isolation Insertion Loss measurement is different based on the JCIMA P2 models Table 6 1 shows the detail frequency range for different JCIMA P2 PIM Analyzers J intcom User Manual Rev 1 02 75
101. ving the IPG file successfully 7 3 3 2 Read Saved Test Result e Press the READ softkey in the Command Bar e The Read CSV Report File window will pop up Read Csy Report File e Select the file and press OK button to read the saved test result J intcom User Manual Rev 1 02 89 JCIMA P2 Multi function PIM Analyzer 8 2 Harmonic and 2 Order PIM Measurement Function JCIMA P2 provides the 2 Harmonic Measurement function for 850MHz band and 900MHz band which will interfere the receive band of 1800MHz band and AWS band This feature can be used to troubleshoot the interference issue caused by 2 Harmonics and 2 Order PIM 8 1 Operating Interface Press the HARMONIC softkey in Function Option Section The 2 Harmonic Measurement function will be selected and the JCIMA P2 will move to 2 Harmonic interface as shown in Figure 8 1 Himen Option gt PIM RTF SPECTRUM ISOLATION VSWR HARMONIC CONFIG LOCK QUIT Section d 7 2 Harmonic Test Curve ass Fail limit dBm Section 2nd Harmonic Test Result 80 Evaluation Section Peak 0 0 dBm Freg MHz Time s dam dBc 2nd Ordrer PIM 32 Test Curve E 2nd order PIM Section Pass Fail imit dBm Test Result ry Evaluation Section Peak 0 0 dBm Command Bar START SAVE READ SETTING Figure 8 1 Operation Interface of 2 Harmonic and 2 order PIM Measurement Function 8 1 1 Function Option Section Please refer Ch
102. worst PIM value lt Pass Fail Limits and Evaluation Setup Pass Fail limit and Provide Pass Fail Result Double Press the area to get the pass fail limit setup popup window in the right 3 1 4 Test Mode Display Section Test Mode Display Section as shown in Figure 3 4 shows current test modes and detailed configured parameters of test carriers F1 and F2 Freq MHz Time s IMS IM5 IM7 IM9 Test Carries Sweep Mode IM Orders Mode Figure 3 4 PIM Test Mode Display Section 3 1 4 1 Configured Parameters of Test Carriers Upon press F1 or F2 softkey following window will pop up to show the detail configured parameters of F1 or F2 unchangeable J intcom User Manual Rev 1 02 26 JCIMA P2 Multi function PIM Analyzer Fl Parameter v F1 Frequency 69 0 874 0 869 0MHz 894 0MHz F1 Power 43 0 10 0dBm 43 0dBm Step 1 0 MHz SweepTimes 1 0 3 1 4 2 Sweep Mode and IM Intermodulation Product Orders Mode The Green bars in Sweep Mode and IM Orders Mode areas show the current sweep mode and IM orders under the test as shown in Figure 3 4 3 1 5 PIM Unit Option In PIM Unit Option Section press the PIM Unit which user wants to use The Green bar in the section shows the current PIM Unit dBm dBc 3 1 6 Test Report Section As shown in Figure 3 5 there are 3 parts in Test Report Section table of test result General PIM Performance and Performance Monitoring of
Download Pdf Manuals
Related Search
Related Contents
FlexScan T2381W カタログ Manual de instalación y mantenimiento Posicionador La renaissance d`un vaisseau fantôme Bedienungsanleitung EB-GD75 Digitales Mobiltelefon XRS Stick Reader User Manual (ES) - Tru-Test Z44R Multi-Purpose Rack Mixer User Manual 32NS4002015-05-10 05:205.5 MB - Wiki Karat USER'S MANUAL Copyright © All rights reserved.