Home
rk267x hipot tester series user manual
Contents
1. working 3 RESET SWITCH press down the button means no HV output 4 Manual port remote control test port 5 V ADJ rotary switch adjust test voltage 6 HVour port test voltage output 1 port for AC test instrument and 2 ports for AC DC test instrument 7 GND connect with one port of the tested 8 OVER LEAK indicator OVER LEAK Indication light and annunciate work when test current leakage exceed pre set value voltage output will be cut off then press down the REST button and Anti clockwisely circumvolve V ADJ rotary switch to the maximum to be ready for next test Operation 9 VOLTAGE meter Three bits digital voltage meter indicate output voltage value 11 CURRENT meter 3 1 2 digital current meter indicate leakage current value 12 TIMER meter 2 bits digital displayer show timing value RK2671B 3 bits digital displayer 13 TIMER rotary switch to adjust to set timing range 14 OVER LEAK pre set adjustor Press down PRE SET TEST switch to pre set leakage current value and display current test result 15 PRESET TEST button Press down to preset and or else to test 16 CURRENT LEAK range Test range are 0 2mA amp 2 20mA 17 CURRENT LEAK switch Test range is 100mA 200mA only for RK2678 18 TIMER MANUAL button Press down to be timing test or else to be manual test 19 AC DC converting b
2. 0 AC 0 2 20 200 mA AC 0 2 20 100 DC 0 2 10 DC 0 2 10 DC 0 2 20 OUTPUT PWR 500VA 500 VA 1000 VA OUTPUT WAVE AC 50Hz SINE WAVE PRECISION A PRECISION TIMING RANGE 1 99sec 5 Manual test 71B for 1 999sec 5 DIGITAL DISP MEAS 320 260 180 380 280 190 440 350 240 500 370 200 WG 7Kg 15 Kg 20 Kg POWER SUPPLY AC 220V 10 50Hz 2Hz DISSIPATION lt 30W STATIC DISSIPATION Pre used caution Read the following items carefully before operating RK267 series voltage withstand test instrument 1 2 3 4 5 6 7 8 9 10 Use three hole power supply plug and insure GND connection well GND port and power supply GND port should be connected well Wear insulation glove stand on insulation mat Anti clockwisely circumvolve V ADJ rotary switch to the maximum before turn on test instrument Before preset all functions reset instrument Don t connect test port and test wire when doing test Don t connect HV output port with shield box or GND wire to avoid instrument damage Turn off power when accident take place Examine and repair when Indicator or annunciator is out of function Operate carefully to avoid hazard when take the remote test IV Explain as the front panel 1 Power switch to control all power supply 2 START switch when press down the button instrument will renew to waiting test status with the light
3. 10 Startup to test after confirming instrument setting and connection 11 Press down STARTUP button adjust V ADJ rotary switch to increase voltage until voltage meter show 3 00 kV If tested leakage current exceed pre set value with voltage upgrading annunciator will indicate and voltage output stop it means the tested is not passed press down RESET button to recover to origin status or instrument will reset automatically when leakage current is under the pre set value 12 REMOTE mode operation insert the aviation five pin plug of test bar to remote test port press down the switch of test bar all time to start test then release to reset Instrument will automatically reset if over leakage current take place 13 CAUTION Timer is disabled if test bar is working it is also same to use out control instrument self service brake switch STARTUP 3 RESET VI Principle diagram voltage adjustor main control board leakage current test the tested VII Others 1 remote test bar 1 piece 2 test wire 1 piece 3 user manual 1 piece 4 certificate 1 sheet 5 dust shield 1 piece VIII Maintenance card cut down along the dashed and post to our corporation SHENZHEN CHUANGXIN INSTRUMENTS CO LTD MODEL SERIES CODE PURCHASE DATE USE DATE DEPARTMENT CONTACTOR POST CODE TEL ADDRESS PROBLEM DESCRIPTION REPAIR REC
4. ORD SHENZHEN CHUANGXIN INSTRUMENTS CO LTD ADD No 106 Fenghe Park Xixiang Avenue Bao an District Shenzhen Guandong China TEL 86 755 23702756 803 FAX 86 755 61577693 http www china item com Email info O china item com
5. RK INSTRUMENT ISO 9001 2000 INTERNATIONAL QUALITY MANAGEMENT SYSTEM CERTIFICATED RK267X HIPOT TESTER SERIES USER MANUAL www china item com SHENZHEN CHUANGXIN INSTRUMENTS CO LTD CONTENTS I General description 2 Main technical index 2 Pre used ____________________ 3 IV Explain 3 V Operation 6 VI Principle 8 Instrument accessories __ 8 VIII Maintenance card 9 I General description RK267X series voltage withstand test instruments are for general purpose HV test operation It can be widely used for voltage withstand test in electrician s assistant instrument rubber wooden facility voltage convertor wires power meter motor power supply plug cables and all kinds of electronic and electric products As the launch of the national security standard Voltage withstand instrument has become one of necessary withstand test instruments to the radio and electronic products manufacturer Operating request environmental temperature 0 40 C relative humidity lt 75 II Main technic index RK2670A RK2671A RK2672C RK2678A RK2674A RK2672A RK2671B RK2672B RK2671D RK2672D AC 0 7 5 15 AC 0 10 20 OUTPUT VOL AC 0 5 10 DC 0 7 5 15 DC 0 10 20 DIGITAL DISP DC 0 5 10 AC 0 5 10 AC 0 5 kV DC 0 5 10 DC 0 5 AC 0 2 20 100 AC 0 2 20 AC 0 2 20 LEAK CURR AC 0 2 20 AC 0 2 20 DC 0 2 20 DC 0 2 10 DC 0 2 10 DIGITAL DISP AC 0 2 20 DC 0 2 10 AC 0 2 20 5
6. evant plug then press down the switch of test bar to start to test Caution Timing function is no of effect when remote control function working at the same time Test example Condition test voltage AC 3000V max over leakage current AC 1 5mA Regular time 30s model RK2671A voltage withstand test instrument steps 1 Check instrument s V ADJ rotary switch to be the anti clockwise end position 2 Plug power wire and then turn on power button 3 Select proper range set voltage range at 5kV position 4 Select proper AC amp DC voltage range set the AC DC switch at AC test position 5 Select proper over leakage current range set the over leakage current range at 2 mA position 6 Pre set over leakage current value press down over leakage current preset switch to PRESET position then adjust over leakage current preset switch to 1 500 mA Insure the switch to jump up and be in TEST position 7 TIMER reset set TIMER MANUAL switch to be at TIMER position and adjust timing rotary switch at 30 seconds range 8 Insert HV test bar to AC voltage output port and another black pothook connect with black GND port of instrument 9 Connect HV test bar GND wire and tested instrument the style to connect is the black clamp connecting with GND port of tested power HV port connecting with another port L or N The tested must be put on insulation worktable
7. utton Press down to be DC model or else to be AC model CAUTION only for AC DC instrument 20 Voltage output convert buttton only for RK2671 amp RK2678 21 Power plug AC 220V plug with inner fuse FRONT AND BEHIND PANEL 21 V Operation 1 CONNECT POWER Insure V ADJ rotary has to be set at 0 position and then turn on power 2 Set LEAK CURRENT value Press down button 15 adjust current leakage preset adjustor 14 to preset needed value 3 Connect test port According to the request of tested object connect test wire with test object well 4 TIMER Press timing button 17 to the TIMER position adjust timing rotary switch to set timing range then press down STARTUP button and adjust V ADJ rotary switch to needed voltage output 5 CONTRAL Set timing switch 18 to manual position then press down STARTUP button 6 In test process instrument annunciator will work to when test over leakage current exceeded the pre set over leakage current then press down RESET button to waiting test status If take the manual control to test the STARTUP button should be unlocked 7 If test over leakage current is less than pre set value unless time is up or press down RESET button instrument will be in the waiting test status 8 Remote controller test Insert the five pin plug of remote controller bar to instrument rel