Home
KISAE Home Solar Kit 1800 User Manual
Contents
1. 4 Home Solar 1800 Owner s Manual Model HS 1800 60 For safe and optimum performance the Home Solar Kit must be used properly Carefully read and follow all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING statements PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Note Due to unit contain large battery capacity upon purchasing immediately charge unit for more than 24 hours or through the solar panel for more than 72 hours depending on the availability of the sun light To guarantee maximum device performance and life span if the unit is not connected continuously to utility power or not connected to the solar panel it is recommended to charge the unit after each use and once every 90 days Disclaimer While every precaution has been taken to ensure the accuracy of the contents of this guide KISAE Technology assumes no responsibility for errors or omissions Note as well that specifications and product functionality may change without notice Important Please be sure to read and save the entire manual before using your KISAE Home Solar Kit Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for future reference Service Contact Information Email info kisaetechnology com Page 2 O oONnonrp yp Table of Contents INTRODUCTION
2. 4 PRODUCT DESCRIPTION cscsniesssccsscccscseccssseessscscesnccnsevucseucceesseersesscssdeseececeases 6 INSTALLATION se 6 CONFIGURATI N iioi to csetera acta ae tornato tee ero cuore maio arare enata uod 9 OPERATION 12 TROUBLESHOOTING 5 1 erint te ssa toti etna nose eese ee ete ee auo 16 xig dee lm 17 OPTIONS FOR EXPANSION 7 centenaire rarae rn rasta testa pror nene phepiun 17 WARRANT Rm 18 Page 3 INTRODUCTION Thank you for purchasing the KISAE Home Solar Kit With our state of the art easy to use design this product will offer you reliable service for providing a solar powered rechargeable power source for your home cabin or campsite With its highly technical design and comprehensive features the KISAE Home Solar Kit will provide you with a simple yet effective user experience as you learn to generate your own power The KISAE Home Solar Kit can run many AC powered appliances whenever you need power Its battery is expandable for times when you require longer run times and its automatic transfer switch built inside means that you can switch seamlessly from household utility power to the power you generate from the sun This manual will explain how to use this unit safely and effectively Please read and follow these instructions and p
3. factory default and exit feature select mode 5 OPERATION WARNING RISK OF EQUIPMENT DAMAGE Do not plug surge protected power bars into the unit s 120 outlets Do not connect an AC power source to the 120 outlets Do not connect the unit s AC power input cord to its 120 outlets Operating the main unit Mode Status Display Condition LED Full Solid Ful AC output is supplied by utility AC power Automatic 9 n Internal battery is fully charged Int Ch1 Flashing Flash XX AC output is supplied by utility AC power Page 12 battery Charging of internal battery by 5A charger capacity is in progress Solid Flash between AC output power is supplied by the inverter amber Output Power through internal battery and or your KISAE in KW amp solar power or another external solar panel XX battery or external charger capacity in 96 Flashing Same as Same as above and utility AC power is just amber above detected and AC output will switch to utility power within a few seconds Solid red E01 E11 Error on unit is detected AC output is disconnected See Trouble shooting section Full Same as Full Automatic Mode but with audio alarm disabled The unit Automatic fault protection features remain active and will shut down without audio Silent warning when fault oc
4. is from utility AC power AC output when Cho Charger amp utility AC is not available Alarm ALO Disable Unit Display Label as shown Utility BackUp Fault To change unit function To enter the feature setting mode press and hold Power and Select button together for about 5 seconds until a beep is sounded Display will show current inverter setting as InO or In1 or In2 Press and hold Select button for 1 second to toggle between the three settings Once the desired setting is selected press and hold Power button for 1 second to set the desired setting and carry on with setting the other feature Display will show current charger setting as Ch1 Press and hold Select button for 1 second to toggle between the two settings Once the desired setting is selected press and hold Power button for 1 second to set the desired setting and carry on with setting the other features Display will show current alarm setting as ALO or AL1 Press and hold Select button for 1 second to toggle between the two settings Once the desired setting is selected press and hold Power button for 1 second to set the desired setting and carry with setting the other features Display will show factory default setting If you desire to use the factory setting Page 11 press and hold Power and Select button together for 5 seconds to exit the setting mode I
5. on the solar panel and it panel Replace Ground Fault shuts down the solar Detection fuse located at the back of panel DC to DC controller battery box Unit has no Unit is off Turn unit on output Unit has shutdown due to Check utility battery voltage and various potential conditions unit settings See Unit Operation section Page 16 7 SPECIFICATIONS Note Specifications are subject to change without notices Inverter Specification Output Current Power 12A 1440W continuous 15A 1800W maximum Surge Power 2880W peak Output Voltage 120 VAC 60 Hz Output Waveform Modified Sinewave Peak Efficiency 9095 No Load battery draw unit in standby lt 3W DC Input Voltage operating range 10 5 15 5 Internal AC Charger Specification Output Current 5 ADC Output Voltage Absorption Float 14 8 13 5 VDC Recharge Voltage 12 6 VDC Efficiency 80 Charger type 3 stages bulk absorption float Solar Panel Charger Specification Output Current 8A maximum Output Voltage 14 8 13 5 VDC Recharge Voltage 12 6 VDC Input DC Voltage 9 26 VDC maximum Efficiency gt 95 Charger Type PWM control Battery Specification Battery Capacity 12V 60Ah Battery Type Sealed Lead Acid Deep cycle Regulatory Approval ETL certify Conforms to UL 1778 Certified to CSA C22 2 no 107 1 8 OPTIONS FOR EXPANSION This Home Solar Kit is a modular design Battery capacity can easily be extended
6. purchasers or users Manufacturer will not be responsible for any amount of damage in excess of the retail purchase price of the unit under any circumstances Incidental and consequential damages are specifically excluded from coverage under this warranty This unit is not intended for commercial use This warranty does not apply to damage to units from misuse or incorrect installation connection Misuse includes wiring or connecting to improper polarity power sources RETURN REPAIR POLICY If you are experiencing any problems with your unit please contact our customer service department at info kisaetechnology com before returning product to retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a unit is returned more than 30 days but less than one year from the purchase date manufacturer will repair the unit or at its option replace it free of charge If the unit is repaired new or reconditioned replacement parts may be used at manufacturer s option A unit may be replaced with a new or reconditioned unit of the same or comparable design The repaired or replaced unit will then be warranted under these terms for the remainder of the warranty period The custom
7. ccurs In2 Setting is Not available for user setting Ch1 not ALO or 1 available In2 Backup Unit will provide output using battery and solar power as Cho Priority higher priority AL1 AC output will only switch to utility mode when battery is low and available Audio alarm is enabled and will sound when any warning or fault occurs Note Only use this mode when there is sufficient solar power to power up the load In2 Backup Same as Backup priority mode but with alarm disabled ChO Priority with Audio alarm will not sound when any warning or fault ALO Alarm occurs The unit fault protection features remain active Disable and will shut down without audio warning when fault occurs Ind Backup AC output is provided by AC utility when utility is available Ch1 Disable Internal battery is automatically charged by the 5A AL1 charger Inverter is disabled and no backup power occurs when AC utility is not available Audio alarm is enabled and will sound when any warning or fault occurs Page 10 Ind Backup amp Same as Backup disable mode but with alarm disabled Ch1 Alarm Audio alarm will not sound when any warning or fault ALO Disable occurs The unit fault protection features remain active and will shut down without audio warning when fault occurs 8 AC output is from utility AC power No AC output when ChO Charger utility AC is not available AL Disable AC output
8. curs In1 Ch1 Alo Auto Solid Ful AC output is supplied by utility AC power backup green Internal battery is fully charged with XX X in 96 AC output is supplied by utility AC power internal Internal battery is not fully charged Display AC show battery capacity charger z disable Solid Flash between AC output power is supplied by the inverter Ini Cho amber Output Power through internal battery and or KISAE solar Alt in kW amp panel or another external solar panel or XX battery charger capacity in Flashing Same as Same as above and utility AC power is just amber above detected and AC Output will switch to utility power within a few seconds Solid red 01 11 Error on unit is detected AC output is disconnected See Trouble Shooting section Auto Same as Auto backup with AC charger disable mode but with audio backup alarm disabled The unit fault protection features remains active and will with shut down without audio warning when fault occurs internal AC charger and alarm disable Int Alo Bark n Solid Flash between AC output power is supplied by the inverter Page 13 amber Output Power through internal battery and or solar power In2 ChO in kW amp Al1 battery capacity in 96 Solid XX in 96 AC output is supplied by utility AC power green Display shows batt
9. d the two battery boxes together and to earth ground by using the supplied ground cable through the Grounding Electrode Terminal Take out the auxiliary DC input port from the main unit and connect it to the second battery box output port Page8 The unit is now ready to provide power to double the run time Tips The second battery box is design to be stackable Using the above procedure can parallel multiple battery boxes CONFIGURATION Please read the following table to fully understand unit settings and desire your own desirable settings Unit default setting is Full Automatic In1 Ch1 Understanding of Unit Setting Inverter Setting Ind Inverter is disabled unit will not provide backup function when utility power is not available Int Inverter is set to standby mode Unit will provide backup function when utility power is not available In2 Inverter is forced to turn on even when AC utility power is available The inverter will only switch back to utility mode when internal battery is getting low With this setting the 5A internal charger is set to by default Charger Setting Cho Internal 5A charger is disabled The charger will not charge the internal battery when utility AC is available Ch1 Internal 5A charger is enabled Charger will automatically charge the internal battery when AC is available Alarm Setting ALO Audio alarm sound is disabled Alarm will not s
10. e sure the solar panel is covered with an opaque sheet or facing the ground before connected or disconnected the cable wire to the solar panel junction box All wiring must be done in accordance with applicable local and national electrical wiring codes Connect Unit to Solar Panel WARNING Shock fire and energy hazards The Solar input port is rated at 17 5V 8A and is designed to be used with the supplied Home Solar Kit 80W solar panel If a non Home Solar Kit 80W solar panel is use be sure the solar panel is design for a 12V battery system and with maximum open circuit voltage less than 25 VDC Please refer to the specifications label on the solar panel before connecting Do not connect with PV source capable of delivering more than 8 amps Connect solar panel with higher voltage or current rating will permanently damage the unit and may cause fire and energy hazard CAUTION Reverse polarity Improper connections reversing the wire connection on the solar panel connection box will cause the unit to malfunction and may permanently damage the unit Damage caused by a reverse polarity connection is not covered by your warranty Plug in the solar panel cord plug to the solar input port located at the back of the KISAE Home Solar Kit battery box Please noted the polarity of the connector Page 7 Remove opaque sheet the solar panel with solar cell surface facing upwards Adjust the mounting fringe of the solar pan
11. el to have the solar cell surface facing directly to the sunlight to achieve the maximum power When sunlight is available the solar charge indicator should automatically turn on and the Solar Charge Indicator should either flash or solid depending on the battery status NOTE It is recommended to always charge the internal battery to a 10096 state of charge as shown by a steady green on Solar charger indicator Disconnect Solar Panel from Unit Cover the solar panel with an opaque sheet or flip the solar panel with the solar cell facing a flat ground to minimize the output voltage to zero volts e Verify the Solar charge indicator is off Disconnect the solar cable connector from the solar input port of the unit Install a Second Battery Box optional Connect the unit with a second battery box P N HSK BX60 will double the unit run time Follow the detail installation guide provide with the second battery box for second battery box installation See also below a brief guideline to access the built in auxiliary DC input port on this main unit and how the secondary battery box is connected Please be sure the AC power cord is unplugged and the unit is turned off Remove the top right panel by unscrewing the two screws located on the top right corners of the panel The auxiliary port is located inside the compartment Place the optional battery box P N HSK BX60 on the right hand side of the main unit Groun
12. er is responsible for the shipping charges on all returned items LIMITATIONS This warranty does not cover accessories such as adapters and batteries damage or defects result from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and maintenance fire and flood If your problem is not covered by his warranty call our Customer Service Department at info kisaetechnology com for general information if applicable Page 18
13. erate uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help LIMITATIONS ON USE Do not use in connection with life support systems or other medical equipment or devices BATTERY RECYCLING The unit is designed to provide years of service However the internal battery is not designed to be user replaceable c the internal battery installed inside the battery box contains lead which can be hazardous if exposed to the environment the battery box should be recycled or safely disposed of at your local recycling depot Do not dispose of the battery box with common household waste Please ask your local authorities about recycling services that are available in your area Page 5 PRODUCT DESCRIPTION T
14. ery capacity Solid red E01 E11 Error on unit is detected AC output is disconnected See Trouble Shooting section Backup Same as Backup Priority mode but with audio alarm disabled The unit priority fault protection features remain active and will shut down without audio with alarm warning when fault occurs disable In2 Ch0 Al 0 Backup Solid Ful AC output is supplied by utility AC power disable green Internal battery is fully charged er Flashing Flash between AC output is supplied by utility AC power green Chg amp XX Charging of internal battery by 5A charger battery is in progress capacity in 96 Backup Same as Backup disable mode but with audio alarm disabled The unit disable fault protection features remain active and will shut down without audio with alarm warning when fault occurs disable Ind Ch1 Alo Backup Solid Ful AC output is supplied by utility AC power and green and battery is full charge charger Green XX in AC output is supplied by utility AC power disable and display shows battery capacity 10 AH Operating the PV Solar Input The battery box is comes with a solar input port and a DC to DC controller that provides an alternative method to charge the internal battery A solar charge indicator located at the back of the battery box to indicate the charging status of the internal battery The DC to DC controller is a fully automatic self sustain
15. f you wish to keep all the previous settings on inverter charger and alarm just press Power button for 1 seconds and press and hold Power and select button together for about 5 seconds to exit the feature setting mode Note Press and hold Power and Select button together for 5 seconds at any time to exit the feature setting mode See feature setting chart below Unit in normal operation Press Power amp Select together for 5 secs to enter feature select mode Press Power amp Select INO gt IN2 together for 5 secs to Press Select for 1 set to select setting and to change setting exit feature select mode Press Power for 1 sec to set to select setting and Lenter next setting Press Power amp Select together for 5 secs to Set to select setting and exit feature select mode CHO CH1 Press Select for 1 sec to change setting Press Power for 1 sec to set to select setting and enter next setting ______ Press Power amp Select Press Select together for 5 secs to Ton Tsee set to select setting and to change setting exit feature select mode Press Power for 1 sec to set to select setting and Lenter next setting Press Power for 1 sec to enter next setting and factory default is not set Factory Default Press Power amp Select together for 5 secs to
16. h and is close to thermal shutdown limit Reduce load and check if any ventilation of the unit is blocked E08 09 Not used E10 Battery reaches high voltage Check battery voltage or if any external charger is connected to the battery box E11 Transfer relay has sensed high temperature and shutdown Check load connected to the output Reduce load and check if any ventilation of the unit is blocked E12 Not used Estimate Run time on Load Following run time is an estimate based on using a single battery box with 60AH battery on specific load used for testing Actual run time may vary Load Consumption Estimate Run time Cordless Phone 5W 90 hrs Home Alarm System 5W 90 hrs Clock Radio 8 50 hrs Table Lamp 40W 60W 10 hrs 6 hrs Freezer 8 8 cu ft 80W 4 5 hrs 20 LCD TV 100W 4 0 hrs Refrigerator 18 cu ft 120W 3 5 hrs Sump Pump 1 2 hp 300W 55 min Microwave mid size 1000W 20 min Coffee Maker 1200W 10 min Page 15 Tips Maximize the usage of your KISAE Home Solar During times of power outage here are some tips to maximize your run times for key back up power applications Do not leave appliances on when not in use because they will drain the internal battery For computer use use laptop or desktop computer with LCD monitor instead of desktop computers with CRT monitor Use small televisions instead of big screen TV
17. he KISAE Home Solar Kit package includes the items list below e Home Solar Kit base unit P N HS 1800 60 80W Folding Solar Panel P N HS SP80 12 Owner s manual P N HS MU1800 INSTALLATION Solar Panel 3 Owner s um manual i AHFUHRFUFLTERE TERTIO II TURIN RH SSeS ee WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS CAN DAMAGE THE UNIT Before beginning your KISAE Home Solar Kit Installation please consider the following e The KISAE Home Solar Kit base unit should be used or stored in an indoor area away from direct sunlight heat moisture or conductive contaminants The solar panel of course can be installed outdoors where the best access to sunlight occurs e When placing the unit allow a minimum of three inches of space around the unit for optimal ventilation When placing the unit allow a minimum of three inches of space around the unit for optimal ventilation e Charge battery immediately upon purchasing this product e To ensure optimum battery run time and life expectancy leave KISAE Home Solar Kit continuously plugged into utility AC power and or leave solar panel plugged into the unit to charge internal battery Main Unit Installation IMPORTANT The AC plug on the power supply cord is used as the disconnect device The socket outlet shall be installed near the equipment and shall be easily accessible To install the unit plug the AC input power cord directly int
18. ing device that will initiate the charge cycle when solar power is available Please note that the DC to DC controller is designed to be used with the provided KISAE 80W solar panel Connected to other solar panel may damage the unit or over charge the battery If insufficient charge capacity is not available from the solar source it is recommended to use the internal 5A charger to complete the battery charging process through the utility Page 14 Understanding Error Codes Error Condition Corrective Action Code E01 Inverter has sensed input under Recharge battery immediately and voltage and has shutdown restart unit E02 Inverter has sensed input over voltage and has shutdown Check battery voltage or if any external charger is connected to the battery box E03 Inverter output has sensed shutdown overload or short circuit and was Check load connected to the output Reduce load and restart the unit E04 Inverter has sensed internal shutdown temperature was high and has Turn unit off and wait for 15 minutes before restarting Check if any object has blocked the air flow of the unit E05 Inverter has sensed low voltage input and warning occurs Recharge battery as unit will shut down shortly E06 Inverter has sensed output load is near high and overload shutdown is Check load connected to the output Reduce load E07 Inverter has sensed internal temperature is hig
19. o a wall outlet and unit is ready to use Note Although the unit is grounded through the ground pin of the AC plug it is highly recommended to ground the battery box through the Grounding Electrode Terminal locates at the back of the battery box Page 6 Follow instruction below to test the unit Turn unit on by pressing and holding the Power button for about a second until a beep sound occur The Status light turns on indicating the KISAE Home Solar Kit is ON The unit is functioning in standby mode and is ready to provide backup power AC output is now being provided directly from utility power e battery capacity is low and needs to be recharged the LED screen on display flashes during the charging process and flashes Ful until battery is fully charged Unplug the input power cord to simulate power failure The status LED on display will turns amber indicate unit is running in backup power mode AC output is now being provided from battery power Reconnect the AC power cord into a wall outlet will switch unit back to standby mode and AC output is now being provided directly from utility power again The unit is successfully installed and functioning properly PV Solar Panel Installation 135 148 Vee 5 ut Porti Batter SOLAR CHARGE 9 6 2 3 Made in China Patent Pending 2H ie WARNING Shock fire and energy hazards Mak
20. ound when warning and fault occur AL1 Audio alarm sound is enabled Alarm sounds when warning or fault occurs Unit Function Setting Mode of 2 Setting Operation Unit Function In1 Full AC output is provide by AC utility when utility is available Ch1 Automatic Internal battery is automatically charged by the AL1 Factory charger default AC output will automatically switch to inverter mode power by the internal battery when utility is not available Audio alarm is enabled and will sound when any warning or fault occurs Page 9 In1 Full Same as Full automatic mode but with alarm disabled Ch1 Automatic Audio alarm will not sound when any warning or fault ALO Silent occurs The unit fault protection features remain active and will shutdown without audio warning when fault occurs Int Auto Same as Full automatic mode but with 5A AC charger Cho Backup disabled AL1 with AC Battery can only be charged by the solar panel or external Charger charger Disable Only use this mode when there is sufficient solar power or external charger to charge the internal battery Int Auto Same as Auto backup with AC charger disable mode Cho Backup but with alarm disabled ALO with AC Audio alarm will not sound when any warning or fault Charger amp occurs The unit fault protection features remain active Alarm and will shutdown without audio warning when fault Disable o
21. recautions carefully NOTE Upon purchasing immediately charge unit through utility power for 24 to 48 hours or through the solar panel for more than 72 hrs To guarantee maximum device performance and life span it is recommended to continuously connect the unit to utility power or solar panel to top up the internal battery or else to charge the unit after each use and once every 90 days IMPORTANT SAFETY INFORMATION This section contains important safety information for the KISAE Home Solar Kit Each time before using the KISAE Home Solar Kit READ ALL instructions and cautionary markings on or provided with the inverter charger the batteries and all appropriate sections of this guide The KISAE Home Solar Kit contains no user serviceable parts See Warranty section for how to handle product issues FIRE AND OR CHEMICAL BURN HAZARD Do not cover or obstruct any air vent openings and or install in a zero clearance compartment Do not use the KISAE Home Solar Kit if the unit is visibly leaking some type of liquid It is possible that the internal battery has been damaged and battery acid may have spilled FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS INJURY When working with electrical equipment or lead acid batteries have someone nearby in case of an emergency Wear eye protection and gloves Avoid touching your eyes while using this unit Keep fresh water and soap on hand in the event batte
22. ry acid comes in contact with eyes If this occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention Batteries produce explosive gases DO NOT smoke or have an open spark or fire near the system Keep unit away from moist or damp areas Page 4 Avoid dropping any metal tool or object on the battery Doing so could create spark or short circuit which goes through the battery or another electrical tool that may create an explosion WARNING Shock Hazard Keep away from children e Avoid moisture Never expose unit to water Unit provides 120Vac from inverter or by pass utility power treat the output socket the same as regular wall AC sockets at home WARNING Explosion hazard DO NOT use the KISAE Home Solar Kit in the vicinity of flammable fumes or gases such as propane tanks or large engines AVOID covering the ventilation openings Always operate unit in an open area Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit Unit exposure to these elements may lead to cracking and decreased capacity of the internal battery FCC INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment gen
23. s Use small desk lamps 25 to 40 W instead of high wattage lamps Battery Replacement The battery box contains a 60AH battery Qualified battery electronic technician is required to replaced the battery To replace the battery please contact customer service for details TROUBLESHOOTING To trouble shoot the unit please note the error code display on the main unit and review the Understanding the Error Codes in section 5 Problem Symptom Solution Products connected to unit malfunction or overheat Products connected to unit do not accept modified sine wave waveform Products are not compatible with the modified sine wave output produced by the KISAE Home Solar Kit See Precaution for using rechargeable application on page XX Insufficient run time Battery is not fully charged Charge battery by leaving the unit plugged to the utility for more than 24 hrs to fully charge the battery or leave the solar panel plugged into the battery box for more than 72 hrs Battery is near the end of it s life Replace battery box Solar Charger indicator is not ON when solar Solar panel cannot supply sufficient power to start the solar charger and Check location and direction of solar panel panel is charge the battery connected Wrong wire connection on Verify solar panel junction box solar panel junction box connection Ground fault is detected Check for any damage on solar
24. with multiple standalone KISAE battery boxes or to external 12 Volt batteries through the external mating connector to connect in parallel with the unit through a pre wired built in internal connector located by the side of the unit External AC or Solar chargers are also available to improve battery charging time For more information please visit www kisaetechnology com or talk to your local supplier Extend unit run time with KISAE solution e Purchase KISAE 12V 60Ah battery box with 8A solar input port P N HS BX60 00 e Purchase KISAE Mating connector with wire and ring terminal P N HS CB175 03 to connect your own 12 Volt battery Reduce battery charging time with KISAE solution The following options are available to improve battery charging time e 20 40A high current charger e 30A DC to DC controller 30A MPPT controller e 80W Solar panel Page 17 9 WARRANTY One Year Limited Warranty The limited warranty program is the only one that applies to this unit and it sets forth all the responsibilities of KISAE There is no other warranty other than those described herein Any implied warranty of merchantability of fitness for a particular purpose on this unit is limited in duration to the duration of this warranty This unit is warranted to the original purchaser only to be free of defects in materials and workmanship for one year from the date of purchase without additional charge The warranty does not extend to subsequent
Download Pdf Manuals
Related Search
Related Contents
Quartzdyne Q-Link Bestron Rapido Descargar Manual Exeom Revolution II Dual Core eucon dsc - Euclid Chemical (Modo de empleo DAPBOXGFPPE EspañolV3) LG DH4220S User's Manual Jacques Vincey rend aux "Bonnes" tout l`éclat de leur RS1500000 Amana Upright Freezers Service Manual Copyright © All rights reserved.