Home
        INSTALLATION / OWNER`S MANUAL
         Contents
1.    2  Use the Mounting Brackets supplied with the heater   see Figure 3 next page     3  Hardware to fasten the Mounting Bracket to the structure is field supplied by the installer  since the type of hardware fastening is determined by site conditions     4  Each Mounting Bracket fastens to the wall using two  2  field supplied bolts or lag screws  through two holes in one side of the bracket  Mount brackets to the wall with a separation  distance of 35    g inches  90 5 cm  to fit the heater between the mounting extensions of  the brackets   see next page     5  Fasten the Mounting Brackets    plumb    and aligned level to each other  35    g inches  90 5  cm  between mounts  so that the heater is oriented horizontally on the long axis     continued        IM110822  InfraSave IEP 4024 Manual 1 0 AD  arr ee    BA    FIGURE 3  MOUNTING BRACKET FIGURE 4  END VIEW WITH  0 4    08    HEATER BRACKET    2x0 2 0   10 mm   20 mm   5 mm  Mount to wall with field    supplied lag bolts  4            Mounting  _  Bracket Lag Bolt Mounting Brackets to Wall  Align brackets level to each other    35    g inches  90 5 cm  between mounts   CC EE  OR   Foo  Ge    6  Ensure that the bolts or lag screws  field supplied  fasten the mounting bracket to the  structure with sufficient strength and integrity to support the weight and prevent move   ment of the heater  The IEP 4024 weighs 8 8 lbs  4 kg   It is recommended to fasten the  mounting brackets to a structural member  wall studs  etc   or a 
2.    Model IEP 4024 f  Wall Fixed Electric Room Heater myra  INDOOR   OUTDOOR NON RESIDENTIAL USE    radiant heaters    A  WARNING Read all instructions before using this heater     Read and understand all installation and maintenance  instructions thoroughly before installing or servicing this equipment     Improper installation  operation  adjustment  alteration  service or mainte   nance can result in the risk of fire and electrical shock  and may cause  property damage  injury or death        SAFETY ALERT     This heater must be serviced only by a qualified electrician  Failure to com   ply could result in personal injury  death  fire and or property damage     Do not operate this heater unless it is properly installed   Always disconnect the heater from the power source prior to servicing     Do not store or use gasoline or other flammable vapours and liquids in  the vicinity of this or any other hot surface appliance     Do not use or locate this model where it could fall into a bathtub or other  water container     Do not cover or block any surface of this appliance     Do not touch this appliance while in operation    Allow to cool after use   Read the IMPORTANT INFORMATION section of        this manual before using this appliance  3154365  Conforms to ANSI UL 2021    SAVE THESE INSTRUCTIONS Certified to CAN CSA C22 2 No 46       INSTALLER  PRESENT THIS MANUAL TO THE END USER  Keep this manual in a secure place   Record the following information for future reference if 
3.   and PART 1 CSA C22 1 in Canada     A mounting bracket is supplied with the heater  and can be mounted to a wall or post  The  heater must be mounted to this bracket during operation  Hardware to fasten the mounting  bracket to the structure is determined by site conditions  and is field supplied by the installer     IMPORTANT  Always maintain the minimum clearances from the floor  ceiling       side walls  and combustible materials  Refer to Table 2 and Figure 2 next page        Locating the Heater     Warning  Use of this heater in coastal salt air regions can result in corrosion of the aluminum  body and reflector  and premature failure the quartz lamp  Corrosion and failure resulting from  use in coastal areas represents normal use in that environment and is not covered by war   ranty     1  The heater is designed for wall or post mounting and must be installed at least 6 feet  1 8  m  above the floor     2  Ensure that clearances from the heater meet or exceed the minimum required clearances  in Table 2  and Figure 2 below  Above  to the Floor  to a Side wall  and to Combustible  materials     3  The heater must be connected to a properly grounded 230   240Vac copper wire circuit   4  The heater should never be placed nor mounted directly under a wall electrical outlet     5  A minimum distance of 3 ft  86 inches   90 cm  must be maintained between the front grille  and flammable items  e g  curtains   walls and other structures     Do not allow an electrical cord to pa
4.  AMPS rey    L1  230   240VAC LAMP 1       230   240VAC  2000 W  60Hz  9 AMPS    e TWO BRANCH CIRCUITS   e COPPER WIRE ONLY     DISCONNECT ALL CIRCUITS PRIOR  TO SERVICING         OPERATING INSTRUCTIONS    The heater must be properly installed prior to use     Always ensure the heater is located at a safe distance from the floor  ceiling  side walls   and combustible materials   refer to Table 2 and Figure 2     Maintain a minimum distance of 36 inches  90 cm  from heater to combustible material   Always be aware and careful of the risk of fire and electric shock     The power cord must not come into contact with hot appliance parts or surfaces and  must not pass in front of the heater     Do not crush the cord  nor drag it over sharp edges  nor place it over a heated hotplate  or open flame     Read  understand  and explain and describe to other users the location  function  and  operation of each control of the heater  including all user operated devices intended to  reduce the risk of fire  electric shock  or injury to persons and warn against tampering  with such     The heater must only be connected to a 230   240Vac  60 Hz  9 amp grounded copper  wire circuit outlet  A time delayed fuse may be necessary for circuit protection     lf the supply cord is damaged  it must be replaced by a qualified electrician in order to  avoid a hazard     High heat is generated from the front of the heater   Do not allow children to touch or play with the heater   Do not use the heater t
5.  keep the heat lamp retainer clips in  place at each end of lamps  Heat lamp is fragile   use cau   tion when feeding wires through holes     Carefully feed each lamp wire from the top of the heater  through the hole in the heater body so that the wire is inside  the heater body  same as the lamp         IM110822  InfraSave IEP 4024 Manual 1   RD  Sn    BA    Heat Lamp Replacement      continued  Step 14    Remove the heat lamp retainer clips both ends of lamps   e One clip at each end of heater  e Two clips in the center of heater    Step 15  IMPORTANT  Wear gloves to handle the heat lamp   Oils from your skin will damage the lamp     The heat lamp is VERY FRAGILE   HANDLE AND ASSEM   BLE WITH GREAT CARE     Carefully slide old heat lamp out of heater through rectan   gular slot in end of reflector        CAREFULLY install new heat lamp and clip in place   Reverse steps above to reassemble the heater     Take particular care not to damage the lamp at Step 14 and Step 13     IM110822  InfraSave IEP 4024 Manual 1 8 nD  kag oN    BA    InfraSave IEP SERIES HEATERS   LIMITED WARRANTY CERTIFICATE    radiant heaters    The Manufacturer warrants to the original consumer that this product is free from defects in material and or  workmanship under normal use and service for a period of one year  12 months  from the date of pur   chase  and subject to the conditions and limitations stated herein  Warning  Use of this heater in coastal  salt air regions can result in corrosion of the a
6.  the electrical con   nection box front face plate in place     Step 5  Slide the connection box front face plate out from the electri   cal connection box     Step 6  Slide power cord retainer plate from electrical connection box   top surface      Electrical       Step 7    Loosen screws in terminal block to remove wires as required       e RED wires connect to Lamp  1  closer to connection box      e BLUE wires connect to Lamp  2  further end from box   e Do not disconnect power supply wires  e Loosen the threaded clamping collar on the Liquid Tight  Connector located behind the wiring terminal  e Pull wires out through the Liquid Tight Connector and top  of electrical connection box       Step 8    Slide lamp wires out of electrical connection box   Set electrical connection box aside        IM110822  InfraSave IEP 4024 Manual 1 6 nD  a aN     BA    Heat Lamp Replacement      continued  Step 9    Remove interior end plate from heater  6 Phillips screws  fasten the heater body end plate in place     Step 10    Slide top cover plates out each end of top side of heater     Step 11  Remove the center Face Plate   e The BOTTOM edge of the center Face Plate does  not have a lower lip  e Insert a fine edged slot screw driver between the  heater body and the BOTTOM edge of the face  plate         e Pry the face plate from the heater body  and re  Bottom Edge  move to storage    Step 12    Slide the end face plates out from each end of the heater     Step 13   NOTE  For this Step 
7. RCUIT BREAKER         Mountin  a Bracket       THIS HEATER IS CONNECTED TO 2 BRANCH CIRCUITS   DISCONNECT ALL BRANCH CIRCUITS BEFORE SERVICING   COPPER WIRE CONNECTION ONLY    IEP 4024 Outdoor   Indoor Use  SPECIFICATIONS    1  Voltage   230   240V  60Hz 1  Operating Position   2  Watts   Amps  Ess Long Axis  Horizontal  Total  4000 W   18 Amps GU  Short Axis  Horizontal to 45      Each  of 2  circuit  2000 W   9 Amps a   i   7  3  Lamp Temperature  2     On    Cycle  Continuous or Intermittent    2420  F  1325  C   360  F  200  C  LAMP LIFE  4 Total Weight  8 8 Ibs  4 kg  1  5 000 Hours  Normal Conditions     IM110822  InfraSave IEP 4024 Manual 6 B Sn    BA    3  PROJECT DESIGN GUIDELINES     NOTE  Also refer to Section 4  Installation  and Table 2 and Figure 2 regarding the  Minimum Required Clearances     The size and quantity of heaters  amount of heat input  required over an area to provide com   fort is affected by the following factors     e General   e Amount of air movement in the area     wind chill    requires additional heat input  e Provide wind breaks wherever possible  e    Spot heating    comfort is most effective if people are heated from at least two sides  e Available mounting height for heaters at the project site    e Indoor application   e    Space heat    the entire structure   accurate heat loss calculation required   or  e    Spot heat    only part of a cold indoor area  e The activity level of the people  seated at rest  hard physical labor  etc     
8. ble fire  do not block air intakes or exhaust in any manner   Do not use on a soft surface  like a bed  where openings may become  blocked     16  To reduce the risk of fire   Do not store or use gasoline  paint  or other  flammable liquids or vapors in the vicinity of the heater           17  Use this heater only as described in this manual  Any other use not  recommended by the manufacturer may cause fire  electric shock  and  death or injury to persons and property damage     18  Do not touch an operating heater or live parts   burns  electric shock and  death or personal injury can result     19  Do not adjust the heater on the swivel bracket during operation  Allow  heater to cool before making any adjustment to heater position     20  Do not stare at the heater Lamp   damage to your eyes could occur   21  After use  allow the heater to cool down before touching  moving  or storing        22  These instructions belong with the heater for ready reference  Keep this  manual in a safe place near the heater     23     SAVE THESE INSTRUCTIONS       IM110822  InfraSave IEP 4024 Manual 5 BD  arr ee    BA    2  HEATER DIMENSIONS  WIRING  SPECIFICATIONS   IEP 4024                   5       Electrical    Connection     145 mm                 aa Quartz Lamps Aluminum Stainless te   17 mm  Heater Body Polished  Aluminum        Reflector  g Mounting  Bracket   Each end   30 5   978 mm  0 4    0 8        10 mm   20 mm   IEP 4024 WIRING DIAGRAM    FUSE   Time Delayed  Slow Blow   OR CI
9. d  negligence  accident  corrosive or con   taminated atmosphere  water  excessive thermal shock  impact  abrasion  normal wear due to use  altera   tion or operation contrary to the owner s manual or if the serial number has been altered  defaced or re   moved  This warranty shall not apply if the voltage to the heater exceeds the rated voltage on the rating  plate by more than 10   The Manufacturer shall not be liable for consequential damages arising out of  or  in connection with  the use or performance of the product  or other indirect damages with respect to loss of  property  revenues  or profit  or costs of removal  installation or reinstallation  or for any default or delay in  performance by its warranty caused by any contingency beyond its control  including war  government re   strictions  or restraints  strikes  fire  flood  acts of God  or short or reduced supply of raw materials or prod   ucts    WARRANTY PROCEDURE  To establish the date of purchase for any purpose under this Limited Warranty  you must retain the original  receipt that can establish the purchase date of your unit  If you do not provide such documents  the start  date of the term of this Limited Warranty will be based upon the date of unit manufacture  plus thirty  30   days  Do not ship a heater back to InfraSave for repair  Contact your local supplier   installer of the  heater  or a local qualified electrician for warranty service or repair     LIMITATIONS AND EXCLUSIONS  This document contai
10. de heat from at least two sides wherever possible                 Contact Schwank Design Services for assistance at design schwankgroup com     IM110822  InfraSave IEP 4024 Manual   nD  arr ee     BA    The design information presented here is intended as a guideline  The accuracy of determin   ing or estimating all factors above will affect performance and satisfaction  Air movement in  particular affects creature comfort     FIGURE 1  RECOMMENDED MOUNTING  COMFORT AREA COVERAGE            i                         Af Di    E o EEN fv  Nr       x dak T ai             t                 J   Approximate Angle of Heat  bt   Dispersion from heater    E  Average Heat  Floor Deck Heater Perimeter Coverage  ft  m  ft  m  ft  m  watts   ft     IEP 6024 6000    e Refer to design guidelines on previous page   e Refer to Required Minimum Clearances  Table 2  amp  Figure 2  Page 10       IM110822  InfraSave IEP 4024 Manual 8 RD Sn     BA    4  INSTALLATION INSTRUCTIONS    General  READ ALL INSTRUCTIONS AND PLAN THE INSTALLATION  BEFORE PROCEEDING    This appliance conforms to ANSI UL 2021 and is certified to CAN CSA C22 2 No 46  This ap   pliance is approved for outdoor and indoor non residential use  Do not use this heater in envi   ronments such as bathrooms and laundry rooms     The heater must connect to a properly grounded 230   240Vac outlet on a copper wire electri   cal supply circuit  Installation must conform with the latest edition Electrical Code ANSI NFPA  NO 70 in the U S A
11. e Do not touch the Quartz Lamp with your fingers   oil from your skin will damage the  Lamp    e  o clean the heater surface  reflector  and air inlets  Use only a dry or damp cloth or  low pressure air stream  computer    duster    in a can     e Do not use any abrasive or caustic cleaning agents    e Never immerse the appliance in water  Danger to life    e  fa heater is exposed to water have a qualified electrician inspect and repair the heater  prior to use    e Inspect the electrical cord for damage or fraying   e Do not operate the heater with a damaged cord  e Have damaged parts replaced by a qualified electrician    IM110822  InfraSave IEP 4024 Manual 1 3 BD  arr ee     BA    9  zeen PARTS   IEP 4024      Electrical  Connection  Box end of   heater       Heater Body   cast aluminum   Polished Aluminum Reflector Assembly   Protective Screen   End Covers with Mounting Bracket Knob Fasteners  Heater Face Plates   Power Cord Retainer Plate  top side    Center Cover Plates  top side     eo ee ee eS    Interior Heater End Cover   9  Connection Box Face Plate   10  Connection Box   11  Terminal Block for electrical connections   12  Power Cord   13  Lamp Retainer Clips  4    14  Extension wires to lamp  2   15   1      2  Heat Lamp  1    2  Each Lamp  2000 Watts   Part   JE 2000 XX    IM110822  InfraSave IEP 4024 Manual 1 4 an E    BA    10  HEAT LAMP REPLACEMENT    A Heat Lamp will operate for approximately 5000 hours under normal conditions  If one lamp  requires replaceme
12. e Outdoor application  Any area heated outdoors is    Spot heat     e NOTE  Model IEP 4024 is for INDOOR or OUTDOOR NON RESIDENTIAL use  e Ensure that the heater model is suitable and approved for outdoor use    e Desired temperature rise   e What is the coldest ambient air temperature that the design must consider   e Then what comfort temperature rise is desired   Indoor to 65      Outdoor to          e Calculate the required input to get the desired average temperature rise     Inout Required per Area per Degree Comfort Temperature Rise           Heat Density   Heat Density  per odes F   per  rt ood C    w  ft   F   w  m   C      Outdoor Heating Ee Up to 10 mph wind  Indoor Spot Heat Protected area   low air movement    o Input   Site Length x Site Width x Temperature Rise x Heat Density per Degree    o Example   e Outdoor Patio  30 ft long by 10 feet wide  e Desired temperature rise  20  F  average over the area   e 30 x 10 x 20 x 2   12 000 Watts total input required    e Compare the values of the available mounting height and area dimensions at the  project site to the recommended mounting heights  length and width of coverage  area  and typical average heat distribution in Figure 1  amp  Table 1  next page     e Layout    e Space the heaters uniformly around the perimeter  and if required  in the center  or throughout the area  to provide sufficient heat density to accomplish the de   sired temperature rise or spot heat only specific locations within the area   e Provi
13. en enen  9  Locating the Heater     annen ennnenenenenen  9  Minimum Required Clearances         10  Heater Mounting  annen eneneen 10  5   Electrical COnnECHON arseen  12  6  Operating Instructions     nanne ennn eneen enen 12  7  Maintenance Instructions         annen eneen 13  Ge GEAN eer E 13  9  MEAE R A Oa 14  10  Heat Lamp Replacement         annen 15  11  Warranty Statement         naan enenenenenenen ennn  18  FIGURE 1  Recommended Mounting  Comfort Area Coverage  FIGURE 2  Minimum Required Clearances      FIGURE 9  Mounting BS FACK Cl resteren eten N  FIGURE 4  End View  amp  Heater Bracket     annen eneen  FIGURE  52 MCG Palenie nikehdhindekbinihee  InfraSave IEP 4024 Manual 3    radiant heaters    IM110822  RD  AUGUST 2011  RL  1A    BA          InfraSave IEP 4024 Manual    1  IMPORTANT INSTRUCTIONS    When using electrical appliances  basic precautions should always be  followed to reduce the risk of fire  electric shock  injury to persons or  death  and property damage including the following      1  Read all instructions before using this heater   WARNING  Risk of fire  Do not use as a residential or household heater     CAUTION  HIGH TEMPERATURE   RISK OF FIRE  Keep electrical cords   and combustible materials  such as furniture  pillows  bedding  papers   clothes  and curtains at least 3 feet  86 inches   90 cm  from the front of the  heater and keep them away from the sides and rear     4  This heater is hot when in use  To avoid burns  do not let bare skin 
14. field supplied support  that is fastened to structural members        7  The heater fastens at each end to the Mounting Brackets using the supplied knob fas   teners and washers through the outermost hole on the extended leg of the Mounting  Bracket     Rotate the heater up to 45   on the short axis by loosening the knob fasteners     9  Once the heater position is established  hand tighten both knob fasteners firmly to main   tain the heater in a secure and stable position     10  Connect each lamp circuit to a 230   240 Vac  60Hz  9 Amp copper wire circuit that is  properly grounded  Electrical connection must be performed by a qualified electrical  tradesperson  Installation must conform with the latest edition Electrical Code ANSI   NFPA NO 70 in the U S A  and PART 1 CSA C22 1 in Canada     11  Never allow an electrical cord to pass in front of the heater or to come into contact with  any hot surface of the heater    12  Read and follow all warnings  and the following section on Operation to enjoy safe op   eration of the heater     IM110822  InfraSave IEP 4024 Manual 1 1 RD  arr a    BA    5  ELECTRICAL CONNECTION    Connect each lamp circuit to a 230   240 Vac  60Hz  9 Amp copper wire circuit that is prop   erly grounded  Electrical connection must be performed by a qualified electrical tradesperson   Installation must conform with the latest edition Electrical Code ANSI NFPA NO 70 in the  U S A  and PART 1 CSA C22 1 in Canada     9     10   11   12     2000 W  60Hz  9
15. luminum body and reflector  and premature failure of the  quartz lamp  Corrosion and failure resulting from use in coastal areas represents normal use in that envi   ronment and is not covered by warranty    ONE YEAR  12 Month  WARRANTY  Subject to the conditions and limitations stated herein and defined below  during the term of this limited  warranty  we will supply any component part of the heater  excluding any labor   which the Manufacturer s  examination determines to be defective in workmanship or material for a period of one year  12 months   from the date of purchase  This warranty applies to the heater   s original owner  and only if the unit is in   stalled and operated in accordance with the printed instructions accompanying the unit and in compliance  with all applicable installation  building codes and good trade practices  Failure to maintain the equipment  through regular maintenance or service by a qualified service technician shall void the warranty     WHAT IS NOT COVERED  The Manufacturer shall not be responsible for any expenses  including service  labor  diagnosis  analysis   material or transportation shipping charges incurred during removal  repair  or reinstallation of this product   or any of its components or parts  All labor  shipping  and or service charges shall be paid by the owner   This warranty does not cover products that have been modified after leaving the factory  improperly in   Stalled  misused  exposed to abuse or damaged by acts of Go
16. ns all warranties made by the Manufacturer and may not be varied  altered or ex   tended by any person  There are no promises  or agreements extending from the Manufacture other than  the statements contained herein  THIS WARRANTY IS IN LIEU OF ALL WARRANTIES EXPRESSED OR  IMPLIED  TO THE EXTENT AUTHORIZED BY THE LAWS OF THE JURISDICTION  INCLUDING SPE   CIFICALLY THE WARRANTIES OR MERCHANTIBILITY OF FITNESS FOR A PARTICULAR PURPOSE   All warranties are limited in duration to 12 months   It is understood and agreed that the Manufacturer s obligation hereunder is limited to repairing or replacing  parts determined to be defective as stated above  In no event shall the Manufacturer be responsible for  any alleged personal injuries or other special  incidental or consequential damages  As to property dam   ages  contract  tort or other claim the Manufacturer s responsibility shall not exceed the purchase priced  paid for the product   All replacement parts will be warranted for the unused portion of the warranty coverage period remaining  on the applicable unit   Some States and authorities do not allow certain warranty exclusions or limitations on how long a warranty  lasts or the exclusions or limitations of incidental or consequential damages  In such cases  the above  limitations or exclusions may not apply to you and are not intended to do so where prohibited by law  This  warranty gives you specific legal rights  You may also have other rights which vary by each jurisdicti
17. nt due to life use failure  we recommend changing both lamps at that time     WARNING    Heater service should only be performed by a qualified electrician  Failure  to comply can result in personal injury  death  fire and property damage     IMPORTANT      ALWAYS DISCONNECT THE HEATER FROM THE ELECTRICAL POWER SUP     PLY PRIOR TO CLEANING  MAINTENANCE  LAMP CHANGE  OR SERVICE        ALWAYS WEAR COTTON OR OTHER FABRIC GLOVES WHEN REPLACING HEAT LAMP   DO NOT TOUCH THE LAMP SURFACE WITH YOUR BARE HANDS   OILS FROM YOUR  SKIN WILL CAUSE DAMAGE TO THE LAMP    The heater requires disassembly to replace the heat lamp    Use a container to securely store disassembled components and screws     Step 1 Ensure power supply is disconnected    Compress the width of the protective screen to retract the  wire tabs from under one edge of the heater body     Rotate the lose edge of the screen up and away from  heater body     Pull the screen away from heater to remove from other  edge of heater body   place safety screen in secure stor   age  Repeat screen removal for other lamp if required                             Step 2  Remove connection box end cover    Six  6  Phillips screws hold the end cover in place     Remove the screws and end cover to secure storage        Step 3    Remove 4 Phillips screws that hold connection box to  heater        IM110822  InfraSave IEP 4024 Manual 1 5 Li E oN    BA    Heat Lamp Replacement      continued  Step 4    Remove the 2 Phillips screws that fasten
18. o dry wet materials or clothing     IM110822    InfraSave IEP 4024 Manual 1 2 RD  arr ee    BA    7  MAINTENANCE INSTRUCTIONS    WARNING    Heater service should only be performed by a qualified electrician  Fail   ure to comply could result in personal injury  death  fire and or property  damage    Tampering with the heater by an unqualified person will void the warranty     WARNING    Always disconnect the heater from the electrical power supply prior to any  cleaning  maintenance or service work     Never immerse the appliance in water  Danger to life     CAUTION  The Quartz Heat Lamp is fragile  Handle the heater with care so  as not to damage the quartz Lamp  Never touch the Lamp with bare fingers   Oils from your skin will damage the Lamp        Inspect the heater prior to each use     e Clean any accumulation of dust or dirt from surfaces and in particular from the reflector  and any air openings in the heater body  refer to Cleaning section below      e Any damaged parts or components must be repaired or replaced prior to operation     Service and Repair   e Disconnect the heater from the power source prior to any servicing  e Important  All repairs must be referred to qualified electrician     e Repairs carried out improperly or by an unqualified person may have serious conse   quences for the user     e Any tampering with the appliance will invalidate the warranty     8  CLEANING   e Before cleaning   Disconnect the heater from the power supply and allow to cool    
19. on           a i i ee ee ee oe oe oD oD a a Da Da aD DD Da aD aD Da D4       IM110822    InfraSave IEP 4024 Manual 1 9 RD  AUGUST 2011    RL     1A  BA    
20. service is required     Model    IEP 4024    Serial     located on heater rating label        IM110822  InfraSave IEP 4024 Manual RD  ae    BA    NOTICE     This contents of this manual are current for this product at the date of manufacture  Occa   sional revision of the product Certification Standard may require changes to the product and   or the content in the product manual  The product must be installed according to the content  of this manual  and or all local and national code requirements     This publication is the intellectual property of Schwank  This publication  or parts thereof  may  not be reproduced in any form  without prior written consent from Schwank  Unauthorized  use or distribution of this publication is strictly prohibited     Schwank Group  Schwank and InfraSave brands    5285 Bradco Boulevard  Mississauga  Ontario  L4W 2A6    2 Schwank Way  Waynesboro  Georgia 30830    Customer  amp  Technical Services  Phone  877 446 3727   Fax  866 361 0523   e mail  csr schwankgroup com    www schwankgroup com  www infrasave com    IM110822  InfraSave IEP 4024 Manual 2 nD  arr ee    BA    infra    IEP 4024    Wall Fixed Electric Room Heater  For INDOOR   OUTDOOR USE    Table of Contents    1  IMPORTANT INSTRUCTIONS                                                   4 Read First     2  Heater Dimensions  Wiring  Specifications                         6  3  Project Design Guidelines      nen  7  4  Installation Instructions   General Information     aaneen ennen ene
21. ss in front of the heater or to touch any hot surface   The appliance must not be mounted directly on flammable materials  no wood or similar    Do not expose the heater to rain or other moisture     S oe    Since the appliance radiates heat  no obstruction or object such as furniture should be  placed between the heater and the person being heated     10  Do not use heater on a soft surface  like a bed  where air openings may become blocked     11  A heater has hot surfaces and potentially arcing or sparking parts inside  Do not use in  areas where gasoline  paint  or flammable vapors or liquids are used or stored     IM110822  InfraSave IEP 4024 Manual 9 BD  arr ee    BA    TABLE 2  MINIMUM REQUIRED CLEARANCES  IEP 4024 Above    A      Floor    F      Clearance    C      Spacing    D    Inches  cm    Inches  cm    Inches  cm    Inches  cm        4000 W  230   240V  60 Hz  18 Amps   9 Amps each of two branch circuits     More than  36     90     12     30    72     180  36     90        FIGURE 2  MINIMUM Required Clearances                LONG AXIS  HORIZONTAL       N    DO NOT PLACE ANYTHING CLOSER THAN 3 ft  90 cm   daai  i  CLEARANCE    C     IN FRONT OF OR BELOW THE HEATER    FASTEN BRACKETS TO STRUCTURAL MEMBER  OR  EQUIVALENT STRENGTH AND INTEGRITY  OF A Kont      COMBUSTIBLE WALL   SURFACE      Heater Mounting    1  Mount the heater on a non combustible surface or structural member  and maintain at  least all minimum clearances indicated in Table 2 and Figure 2 above 
22. touch  hot surfaces     Use this heater only when it is properly installed     Extreme caution is necessary when any heater is used by or near children  or infirm persons  Always supervise children and instruct and ensure that  they do not play with the heater     7  Always disconnect power source to heater when not in use  Never leave the  heater unattended during operation     8  Do not operate any heater with a damaged cord or after the heater  malfunctions  has been dropped or damaged in any manner  Return heater  to an authorized service facility for examination  electrical or mechanical  adjustment  or repair    9  This heater is not intended for use in bathrooms  laundry areas  and similar  indoor locations  Never locate heater where it may fall into a bathtub or  other water container    10  Do not cover cord with throw rugs  clothing  or the like    11  Arrange the cord at the side and back of the heater   do not allow cord to  drape over the heater    12  To disconnect heater  turn controls to    off     or switch off at power source    13  Only connect the heater to a 240Vac copper wire circuit that is properly  grounded    14  Do not insert or allow foreign objects to enter the heater or any ventilation  or exhaust opening as this may cause an electric shock  fire  or damage the  heater   death  personal injury or property damage could result     continued        IM110822  4 RD  AUGUST 2011  RL  1A    BA    IMPORTANT INSTRUCTIONS continea    15  To prevent a possi
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  51938 TECSPEC  Check-list de la HAS - CClin Sud-Est  dissertação final - Repositório Institucional da Universidade    Copyright © All rights reserved. 
   Failed to retrieve file