1. BLACK a WHITE PUMP BAGH 3 aao ITION PLUG FUSE _k PLUG SWITCH 1 AMP 1 rea BLACK i h 79331 ORANGE 39233 RED p WHITE N 79327 79325 WHITE CAP B TYP 9 PLACES us I3 TO 79330 BLACK 3g N 99 1a N HEATER BLOWER 79550 BLACK bb 5b to xS xS 42175 ye WIRE HARNES HEATING BUCKET PUMP ELEMENT THERMOSTAT BLACK BLACK 79330 79330 WHITE 38980 BLACK WHITE GREEN POWER CORD Ii 2396A Bag In A Box Counter Butter Dispenser COUNTER TOP CUTOUTS Lhe x Sr ie oh 2 48 1 is J a 252 6 2 PEDESTAL 5 MOUNTING DIS r SAN DRIP PAN CUT OUT 3 8 DIA meu P FOR 1 4 20 BOLTS 4 PLACES Y Cy Lu aC Y IWO GOT GUTS a i N FOR 2Z596AD E M 1 pele ONLY A A 1 aN PEDESTAL Re MOUNTING 25 DRIP PAN CUT OUT 9 32 DIA meu P FOR 1 4 20 BOLTS 4 PLACES 9 All Models 2396AD and 2396A Bag In A Box Counter Butter Dispenser WARRANTY WE WARRANT to the original purchaser the Gold Medal equipment sold by us to be free from defects in material or workmanship under normal use and service Our obligation under this warranty shall be l
2. Plug the six prong power cable from the pedestal into the side of the control box on top of the rack assembly 6 Plug the power cord from the rack assembly into a proper outlet 7 Load two boxes of pre heated topping into the rack Gold Medal s Backroom Warmer Item 2262 may be purchased for pre heating the topping Remove the cardboard cutout on the box to expose the quick disconnect fitting 8 Attach the quick disconnect fitting on the end of the tubing to the fitting on the box of topping 9 The unit is now ready for use me 3 All Models 2396AD and 2396A Bag In A Box Counter Butter Dispenser OPERATING INSTRUCTIONS Turn the master power switch located on the front of the control box to the PUMP amp HEAT position This will start the heater blower that will maintain cabinet temperature activate the foil heater in the pedestal and provide power for the pump Pressing and holding either of the red buttons located on the pedestal will dispense topping If this is the first time the unit has been used it may take a minute to completely fill the tube and dispense topping Turn the master power switch located on the front of the control box to the HEAT ONLY position This will start the heater blower that will maintain cabinet temperature and activate the foil heater in the pedestal only The pump is de activated CLEANING INSTRUCTIONS SANITIZING INSTRUCTIONS Your Model 2396AD and 2396A is all stainless steel
3. Foil Heat Element 8W 120V 2 1 15 38971 Momentary Switch 4 2 16 38990 Thermostat 135F 1 1 17 38995 Heater Deflector 1 1 18 38998 Retaining Strap 2 1 19 39012 8 32 2 PH PAN MS 18 8 4 4 20 39140 Manual 1 1 21 39246 Short Feed Tube 4 2 22 39247 Long Feed Tube 2 1 23 39410 3 Position Rocker Switch 1 1 24 39413 Switch Label 1 1 25 40721 Axial Fan 1 1 26 41033 Pilot Light 125V Red 2 1 27 41499 Wire Harness Oil Pump 2 1 28 47199 Blower plug and cord 1 1 29 74636 Fuse Holder Mighty Mite 2 1 30 74725 Ballast 120V 2 1 31 74727 Lamp Double Tube 120V 2 1 32 75220 Hose Clamp Screw 12 6 33 76026 Strain Relief SR 6P3 4 1 1 34 79100 Bag Connector 2 1 35 79129 Cinch Jones Plug 2 1 36 79269 In Line Strainer 2 1 3 19341 1 AMP Fuse 2 1 36 79377 Control Box Cover 1 1 39 79378 Top Rack Weldment 1 1 40 79420 Control Box 2396AD 1 wn 41 79375 Control Box 2396A 1 4 79425 Lower Rack Weldment 1 1 43 79888 BIB Butter Pump 2 1 44 89045 Strain Relief T amp B 3302 4 2 7 All Models 2396AD and 2396A Bag In A Box Counter Butter Dispenser ELECTRICAL SCHEMATIC 38982 38981 MOMENTARY SWITCH COM N O ORANGE BLACK ORANGE BLACK 0 COM N O MOMENTARY SWITCH GREEN L BLACK ORANGE eee RED n 7 WHITE PEDESTAL PLUG FOIL HEATER
4. construction The exterior surfaces can be cleaned by wiping oil spills with a dry towel then wiping with another towel moistened with mild soap and warm water Sanitizing the internal parts tubing pump etc 1 2 Disengage the bag connector from the bag of oil and place in a pail of hot water and mild soap Approximately 1 gallon Push the dispense button to flush the system of oil Make sure you have a container under the discharge tube Discard the oil Put the intake line in the hot water and pump it through the lines by holding the dispense button until the pail is empty Fill the pail with a sanitizing solution Gold Medal offers a product for this purpose Chlor Tech part number 1109 Put the bag connector in the pail of sanitizer Pump it through the lines by holding the dispense button until the pail is empty It is not necessary to flush the sanitizer before the next step but you may flush with water if desired Before the next use install the connector to a bag of oil and pump oil until oil is dispensed through the discharge tube schedule for Cleaning The recommended sanitizing schedule is every night IMPORTANT This product is not intended for use with volatile food products i e real butter 4 All Models 2396AD and 2396A Baq In A Box Counter Butter Dispense MAINTENANCE INSTRUCTIONS THE FOLLOWING SECTIONS OF THIS MANUAL ARE IN TENDED ONLY FOR QUALIFIED SERVICE PERSONNEL WHO ARE FAMILIAR WITH ELECTRI
5. CAL EQUIPMENT THESE ARE NOT INTENDED FOR THE OPERATOR Adequate eye protection must be used when servicing this equipment to prevent the possibility of injury E DANGER Do NOT immerse the equipment in water Unplug your machine before servicing 5 All Models 2396AD and 2396A r lt Bag In A Box Counter Butter Dispenser ORDERING SPARE PARTS Identify the desired part by checking it against the photos illustrations and or the parts list When ordering please include part number part name and quantity desired Please include your model name and machine serial number located on the machine nameplate with your order Address all parts orders to Parts Department Gold Medal Products Co 10700 Medallion Drive Cincinnati Ohio 45241 4807 or place orders at 513 769 7676 800 543 0862 Fax 513 769 8500 E mail goldme19 eos net 6 All Models 2396AD and 2396A Bag In A Box Counter Butter Dispenser PARTS LIST DISPENSER ASSEMBLY 2396AD 2396A Item No Part No Description Qty Qty 1 22038 Lead in Cord 15 Amp plug 1 1 2 38566 Butter Pump No Drip Spout 2 1 3 38796 Socket Cover 2 1 4 38773 Socket Double Tube 2 1 5 38824 Modular Heat Element 1 1 6 38872 Pedestal Back Plate 2 1 7 39142 Dispenser Label 2 1 8 38874 Pedestal Weld Assembly 2 1 9 38876 Top Pedestal Cover 2 1 10 38877 Top Pedestal Plate 2 1 11 38936 Drip Pan 2 1 12 38938 Pan Insert Weldment 2 1 13 38969 Spout 2 1 14 38970
6. Part No 39140 Revised May 2002 Bag In A Box Dual Pedestal Counter Butter Dispenser Instruction Manual Model 2396AD and 2396A H UNFOOD EQUIPMENT amp SUPPLIES Cincinnati OH 45241 4807 USA Bag In A Box Counter Butter Dispenser safety Precautions f mi g ra A Pic r ha L 4 a F 1 J J T 4 al This equipment is designed and sold for commercial use only This equipment is not to be used by the consumer in home use Do not allow direct contact of this equipment by the public when used in food service locations Only personnel trained and experienced in the equipment operation may operate this equipment Carefully read all installation instructions before operating the equipment Always wear safety glasses when servicing this equipment Any alterations to this equipment will void the warranty and may cause a dangerous situation NEVER make alterations to the equipment DANGER Machine must be properly grounded to prevent electrical shock to personnel Do NOT immerse the equipment in water Always unplug the equipment before cleaning or servicing NOTE The information specifications and illustrations contained in this manual represent the latest data available at time of publication Right is reserved to make changes as required at the discretion of Gold Medal Products Company without notice 2 All Model
7. imited to the repair or replacement of any defective part for a period of six 6 months from the date of sale to the Original Purchaser with regard to labor and two 2 years with regard to parts and does not cover damage to the equipment caused by accident alteration improper use voltage abuse or failure to follow instructions THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON OUR PART INCLUDING THE IMPLIED WARRANTY OF MERCHANTIBILITY THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF We neither assume nor authorize any other person to assume for us any other obligation or liability in connection with the sale of said GOLD MEDAL equipment or any part thereof The term Original Purchaser as used in this warranty shall be deemed to mean that person firm association or corporation who was billed by the GOLD MEDAL PRODUCTS COMPANY or their authorized distributor for the equipment THIS WARRANTY HAS NO EFFECT AND IS VOID UNLESS THE ORIGINAL PURCHASER FIRST CALLS GOLD MEDAL PRODUCTS COMPANY AT 1 800 543 0862 TO DISCUSS WITH OUR SERVICE REPRESENTATIVE THE EQUIPMENT PROBLEM AND IF NECESSARY FOR INSTRUCTIONS CONCERNING THE REPAIR OR REPLACEMENT OF PARTS NOTE This equipment is manufactured and sold for commercial use only GOLD MEDAL PRODUCTS COMPANY 10700 Medallion Drive Cincinnati Ohio 45241 4807 USA 10 A
8. ll Models 2396AD and 2396A
9. s 2396AD and 2396A Bag In A Box Counter Butter Dispenser INSTALLATION CHECKING SHIPMENT Your new Bag In A Box Counter Butter Dispenser is ready for installation in your counter Remove the machine from the corrugated carton Check thoroughly for any damage which may have occurred in transit Damage claims should be filed immediately with the transportation company ELECTRICAL REQUIREMENTS Model No 2396AD 120 Volts 2 9 Amps 348 Watts 60 Hz Model No 2396AD 120 Volts 2 5 Amps 300 Watts 60 Hz DANGER Machina must be properly grounded to prevent shock in case of electrical problems INSTALLATION INSTRUCTIONS 1 The bottom portion of the counter butter dispenser needs to be placed in an area under the counter that can be enclosed on all sides in order for the heater to properly maintain the product temperature Access will be required to the front of this area allowing sufficient clearance to clean and maintain the pump and add or remove boxes of topping The countertop will require preparation by drilling the mounting holes and by cutting the rectangular holes for the power cable the tube and the drip pan If your counter is thicker than the provided mounting studs attached to the pedestal then counter bore the underside of the counter top to allow for the wing nuts Set the pedestal onto the counter top and secure it in place with the wing nuts Set the rack assembly into the opening under the counter