Home

805 User Manual

image

Contents

1. Oo Oo Or AJOJN IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 The Primary Entry delay is seconds The Secondary Entry delay is seconds The Exit Delay is seconds 5 Arming the System There are various options for arming the system 5 1 Away Arming Procedure 4 USER CODE Leave via Entry Exit Zone 1 Ensure that the READY indicator is illuminated if not check that all protected doors and windows are closed and that motion has ceased in areas covered by motion detectors 2 If necessary close the front door 3 Press the key to cancel any unintended key entries 4 Entera valid 4 digit USER CODE If you make a mistake press the key and re enter the code 5 The ARMED indicator will illuminate and the keypad s buzzer will sound on and off for the duration of the exit delay Any bypassed zones will be shown by a steagy illuminated zone indicator 6 Thearming process has begun Leave only via the follower and entry exit zones 7 The panel will arm at the end of the exit delay OR If the panel is so programmed violating the Push to Arm zone will arm the panel immediately 5 2 Quick Away Arming 1 Hold down the key until the keypad buzzer sounds If this function is enabled it is possible to AWAY arm by simply holding down the 1 key until the keypad buzzer sounds and the arming process
2. IDS805 Users Guide to Keypad Functions MANUAL NO 700 266 01A ISSUED NOVEMBER 2003 VERSION 1 00 Summary of Operation Arm disarm 4 USER CODE Quick Away Arm Hold down 1 for 1 second Quick Stay Arm Hold down 5 for 1 second Quick Stay Arm amp Go Hold down 6 for 1 second Panic Hold down P for 1 second Fire Hold down F for 1 second Medical Emergency Hold down M for 1 second Alarm Memory Hold down 0 for 1 second Change Stay Profile MODE 9 PROFILE NUMBER x Bypass a zone ZONE NUMBER Program chime zone Hold down 2 for 1 second ZONE NUMBER x Program stay zone Hold down 3 for 1 second ZONE NUMBER x Program buzz zone Hold down 4 for 1 second ZONE NUMBER x View Trouble Status Hold down 7 for 1 second Duress DURESS CODE IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 cn o 5 Introduction to the IDS805 6 iE o pM 6 2 Understanding the Keypad Indicators 7 3 Operation of the Keypad 8 4 System Information eese 8 4 1 Programmed Functions xcs cierto aria tnter cnn 8 42 User ee m 9 4 3 sone TOF P ID ua ciue oc ra puc cone date
3. Refer to the illustration on inside front cover of manual 1 ARMED Indicator Red Illuminated System Armed Extinguished System Disarmed Flashing Alarm Condition or Memory AWAY Indicator Red m Illuminated System Armed in Away Mode Extinguished System Disarmed Stay Mode e POWER Indicator Red Illuminated Mains Power is present Flashing Trouble Condition READY Indicator Green Illuminated System is ready to be armed ZONE Indicators Yellow P 5 Illuminated Zone bypassed xinguished lashing Zone violated IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 7 3 Operation of the Keypad To ensure correct operation of your security system it is essential to familiarize yourself with the use of the keypad The keypad has a buzzer command entry keys zone and system status L E D s The keypad is used to send commands to the system and to display the current system status The keypad s will be mounted in a convenient location within the protected premises generally close to the entry exit zones After a preprogrammed period of inactivity the keypad will automatically enter into a power save mode by turning off all the indicators The keypad wakes up or re illuminates when any key is pressed or any zones are violated The power save feature is programmable and may be disabled A sensor which has registered an alarm condition will be indicated on th
4. If the zone 8 LED is illuminated contact your alarm installer immediately It will not be possible to arm the system until the installer mode has been entered by entering the installer code Does the siren sound before you exit The exit delay may be too short ask your installer to adjust the exit delay OR You have not left via a follower and entry exit zone or have strayed into an instant zone Either avoid these zones or ask your installer to change the zone type 15 3 Problems when disarming the system Does the siren sound immediately upon entry You have not entered via the entry exit zone or have strayed into an instant zone Does the siren sound before you get to the keypad You have strayed into a non follower zone OR You have taken too long to get to the keypad The panel will not disarm You may have entered an incorrect code Press the key first then re enter your user code 15 4 For Service Central Station Information Account Telephone Installer Information Accounts elephne 26 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 A Alarm Memory sse nennen 2 5 7 18 19 d ocu testet ot terit oer ferret S 2 5 8 10 14 25 DCN EE 10 12 QUICK AWAY testa EN settee 2 8 10 QUICK Stay ist cose tcc ote enint terio pee a EAren 2 8 12 Quick Stay
5. A GO reie e aped Deva sep c dene dde 2 8 12 Sii DET 2 5 8 11 12 13 21 22 23 Slay Q GO EE 5 Away OGG e 7 AUTO AMING E 13 B BANEN ee getut oii dese ade deir del eo qo EA UH rr eei ea TA 6 25 BUZZ ZONE ostia ete io PPP EEPEEQE RENS 2 9 11 12 21 22 23 Bypass ssssss 2 5 7 10 11 12 13 14 15 18 19 21 25 C Control Panel E 6 CHAINS ELE MARET METTE DERE 2 8 9 23 24 D Disaini si SENI ELCHE 2 5 15 16 17 26 BUB 2 9 17 19 E Emergency Evacualtlon oci essence E 18 Entry Delay 4 uec cci eria ner ipt it ea b Ene Lena et uera tege 8 14 15 POMA M 10 SECOMOANY ours ieena aA rudentes tended eae uas 10 Entry Exit Zone see Zone Exit Delay pM 5 8 10 13 26 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 27 RIPE UN au 2 5 6 8 16 Follower Zone see Zone Forced Ammmimg esses enne 8 14 l Installer Code C a ia 25 26 Installer Reset sssseeeeseseeeeeenennennnnnn nnne 9 25 26 Instant Zone see Zone K yd m 9 13 16 M Maid ee E 9 21 Master User Code 9 19 20 MECCA EE 2 5 17 MODE EE 2 11 P PANIG m 2 9 17 P wer Save Mode m 8 Problem e enean e an a a a AE e EENE 25 26 Push to Arm Zone see Zone Q Quick Away Arming see Arm Quick Stay Arming see Arm Quick Stay Arm amp Go s
6. tE 9 5 Arming the SySIOI e eoi ec accreted 10 5 1 Away Arming Procedure AAA 10 52 Quick Away E 10 5 3 Stay Arming Nae 11 5 3 1 To Enter a Stay Profile 11 5 3 2 Io Stay EE 12 5 4 Quick Stay Arming seen 12 5 5 Slay Arm and QO WEE 12 5 6 Arming from a Key Switch or Remote Control 13 S7 PROTO PAWN T 13 5 8 Arming with Entry exit or Follower Zones Violated 14 9 9 e BO dun Une rm 14 6 Zone BYPASSING TT 14 6 1 To Bypass a Zone seen intente rtt mtm tke 14 6 2 To Un Bypass e E 15 7 Disarming the System esee 15 7 1 Disarming with a User Code sssssseeessseeesserreserrrrerrrnene 15 7 2 To Disarm with a Key Switch or Remote Control 16 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 3 8 Emergency Situations eese 16 8 1 Fire Alarm aient curio pute eimi rout tenaci dina 16 8 2 Panic NN et oder eint e ne tiri de n nete reece 17 MI RUP HM 17 SOME IT TE M 9 0 Emergency Evacuation Plan 18 10 System Memory EE 18 10 EE ent IO e E 18 10 2 Zone Bypassed Memory eeeseeesess 19 10 9 Zone Tamper Memory sic ccscicesccceccashoccesevcoodioravneteatseecenouses 19 1l User Codes neret ta nn akn n niunn sauniai cuna ud 20 11 1 Entering New and Changing Existing User Codes 20 11 2 Deleting User
7. Cocdes AAA 20 11 3 Mads 80 s T m 21 12 Stay LONG mee 21 12 1 To Program Stay Zones ciscicessccsoiasivasssocetncetersoieanebetaweras 21 12 2 To Cancel the Stay VOI IBS oco eac egene 22 13 roa poc ARSA 22 1941 To Program Buzz ZOrIBS i ous cett bet bap bee pde 22 15 2 To Cancel BUZZ JOBS o eerie ento oa ree eror aine 23 14 Chime ZONES Mr 23 14 1 To Program the Chime Zones AER 24 14 2 To Cancel the Chime Zones AE 24 15 Trouble Shoolllit iuret Romain Erin nce 24 15 1 Trouble Conditions aote o Ete eri en EDDIE bue Rev een 24 15 1 1 Viewing the Trouble Conditions seeseeeseeeeeeeeeeereeeseeeeeeeee 25 15 2 Problems When Arming the System 25 15 3 Problems when disarming the system 26 15 4 For Service Mm 26 4 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 Alarm Memory Arm Bypass Disarm Entry Exit Zone Follower Zone Instant Zone Stay Arm Stay Arm and Go Stay Zone Zone This is the history of the most recent violations that occurred the last time the system was armed To set the system into the ARMED mode In this mode violating a zone will activate an alarm condition If the System is programmed accordingly will cause a reporting code to be sent to the monitoring company To deactivate a zone When the panel is ARMED violation of a bypassed zone will be i
8. at the panel is in the Stay Zone programming mode 3 Press the NUMBER corresponding to the STAY zone you wish to cancel followed by the x key 4 Therelevant zone indicator will extinguish 5 Press the key to exit the stay zone programming mode NOTE The system will automatically exit this mode after 60 seconds 13 Buzz Zones Buzz zones are used when Stay arming When triggered buzz zones will cause the keypad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during this period the system will register an alarm condition It is advisable to program Buzz zones if you are likely to accidentally trigger these zones or if you have pets This feature helps prevent unnecessary false alarms 13 1To Program Buzz Zones 4 ZONE NUMBER x 1 Ensure the READY indicator is illuminated 22 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 2 Hold down the 4 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is armed in the Buzz Zone programming mode 3 Press the NUMBER corresponding to the zone you wish to be a Buzz zone followed by the x key 4 Therelevant Buzz zone will be shown by the illuminated zone indicator Stay zones will be shown by flashing indicators See Section 12 A Stay zone cannot be selected as a Buzz zone the Stay status must be clear
9. ate profile before the system is armed The arming procedures and quick keys will have effect on the selected profile STAY and BUZZ zones can be programmed for each profile once the profile has been entered 5 3 1 To Enter a Stay Profile MODE 9 PROFILE NUMBER 1 Press the key to clear any previous entries 2 Press MODE IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 11 Press 9 then press 1 or 2 for the required profile Press x to enter Along double beep should be heard Program STAY and BUZZ zones for the profile or ARM the profile See sections 12 and 13 o PO 5 3 2 To Stay Arm 7 USER CODE Do not leave premises 1 Select the required STAY PROFILE 2 Ensure that the READY indicator is illuminated if not check that all protected doors and windows are closed and that motion has ceased in the areas covered by motion detectors 3 If necessary close the front door 4 Press the key to cancel any unintended entries 5 Enteravalid USER CODE 6 DO NOT open the front door If the front door is opened the System will arm in AWAY mode 7 The ARMED indicator will illuminate and the keypad buzzer will sound on and off for the duration of the exit delay 8 The AWAY indicator will remain extinguished 9 Any STAY zones shown by a steadily illuminated indicator will be automatically bypassed 10 Ensure that you enter only those z
10. begins 10 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 5 3 Stay Arming Procedure This allows the user to arm the perimeter zones while disabling the interior zones so that it is possible to remain on the premises If zones are likely to be violated accidentally they should be programmed as BUZZ zones refer to page 22 The panel can be programmed with two different STAY PROFILES to be used as required Following is an example of where this may be used Assume a property has perimeter sensors to secure a garden fence and a number of internal sensors within each room of the house The first STAY PROFILE would function as follows At night while you are within the house going about your normal evening activities it may be desirable to activate the alarm such that any violation of the perimeter sensors will cause an alarm Therefore this profile would have all internal sensors programmed as STAY zones bypassed and perimeter sensors would be normal alarm zones A second STAY PROFILE would then be utilised once the family retires to their bedrooms All bedrooms would therefore be STAY zones bypassed while unused zones i e a lounge and TV room together with perimeter zones would be normal alarm zones NOTE Once a particular stay profile is selected the system will use the selected profile each time the system is armed into the STAY MODE If the alternate profile is required it is necessary to select the altern
11. ctice escape procedures 10 System Memory 10 1 Alarm Memory The Alarm Memory displays any zones which were violated or bypassed the last time the system was armed If the ARMED indicator is flashing before you disarm the system a violation has occurred To view which zone was violated disarm the panel and continue as indicated below To Display Alarm Memory 0 Hold down the key until the keypad buzzer sounds 1 Hold down 0 until the keypad buzzer sounds 2 The READY indicator will extinguish and the keypad buzzer will sound briefly 3 Flashing zone indicators show which zones were violated during the last armed period 4 The memory status will be displayed for five seconds or until the is pressed 18 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 5 The alarm memory will be erased the next time the system is armed 10 2 Zone Bypassed Memory The Zone Bypassed Memory displays any zones which were bypassed during the most recent arming cycle To Display Zone Bypassed Memory 0 then 1 ch Hold down 0 until the keypad buzzer sounds 2 The READY indicator will extinguish and the keypad buzzer will sound briefly 3 Flashing zone indicators show which zones were violated during the last armed cycle 4 To view any bypassed zones press the 1 key once 5 Zones that have have been bypassed will have flashing indicators 6 The memory status
12. d this function if it is required Press this key only in an emergency situation that requires response by emergency personnel Medical Alarm M Hold down the key until the keypad buzzer sounds If the M key is pressed until the keypad beeps approximately 1 second a MEDICAL ALARM condition will be activated The keypad s buzzer will sound rapidly for 5 seconds to indicate that a medical alarm has been initiated Duress Code DURESS CODE This is a special 4 digit user code which should only used in the unique situation where an intruder forces one to disarm the system under duress When the DURESS CODE is entered the control panel disarms normally however a DURESS REPORTING CODE is trans IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 17 mitted to the monitoring company to inform them that you have been forced to disarm the control panel by an intruder Itis advisable to choose a code that can be easily remembered by all family or staff members 9 0 Emergency Evacuation Plan An emergency evacuation plan should be established in case of a fire Draw up a floor plan of your premises showing windows doors stairs and rooftops that can be used for escape Indicate a suitable escape route for each room Always keep these routes free of obstruction Establish a meeting place outdoors for a headcount of the building s occupants Pra
13. e press the key corresponding to that zone followed by the x key The zone indicator will illuminate 4 Program any other zones you wish to select as chime zones as per step 3 5 Press the key to exit the chime programming mode 14 2 To Cancel the Chime Zones 2 ZONE NUMBER 4 1 Hold down the 2 key until the keypad buzzer sounds 2 The AWAY indicator will flash to show that the panel is on the chime programming mode 3 To cancel any chime zones press the key corresponding to that zone followed by the x key The zone indicator will extinguish 4 Press the key to exit the chime programming mode NOTE The system will automaticaly exit this mode after 60 seconds 15 Trouble Shooting 15 1 Trouble Conditions In the event of a trouble condition the power indicator will flash Trouble Condition refers to Low Battery power and or AC Mains Failure Check that the plug is in place and switched on If the power indicator is still flashing once these checks have been done contact your installer who will then check the battery power 24 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 15 1 1 Viewing Trouble Conditions 7 Hold down the key until the keypad buzzer sounds If the POWER LED is flashing or if so programmed the keypad is beeping hold down the 7 key for two seconds The ARMED AWAY and READY indicators will start flashing
14. e keypad by the corresponding zone light flashing The keypad buzzer will sound under the following conditions When any key is pressed during the entry of codes Three times if one or more of the zones are violated when attempting to arm the system To indicate a trouble condition During the entry exit delay Will sound 5 times when a chime zone is violated 4 System Information 4 1 Programmed Functions Check with your installer which of the following functions have been enabled Quick Away Arm Quick Stay Arm Arm with Entry Exit or Follower Zones Violated Stay Arm Stay Arm and Go Forced Arming Push to Arm Siren Sound on Arm Disarm double toot arm short toot disarm Panic Alarm Fire Alarm P P P P ate DODCDODCDODDUO IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 mE mE mi m mA m Chime Zones Buzz Zones Zone Tamper Monitoring Arm with Key Switch or Remote Control Exit Delay with Key Switch or Remote Control Installers Reset after Alarm 4 2 User Codes User No User Code User Name 01 Default Master Code 1234 NEW Code 02 03 04 05 06 07 08 09 10 11 12 13 14 Maids Code 15 Duress Code 4 3 Zone Information Zone Zone Type e g Entry Exit Zone Name e g Kitchen door 1
15. ed first 5 Repeat steps 1 3 until all the required Buzz zones are programmed 6 Press the key to exit the buzz programming mode 13 2 To Cancel Buzz Zones 4 ZONE NUMBER 1 Ensure that the READY indicator is illuminated 2 Hold down the 4 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is armed in the Buzz Zone programming mode 3 Press the NUMBER corresponding to the BUZZ zone you wish to cancel followed by the x key 4 The relevant zone indicator will extinguish 5 Press the key to exit the buzz zone programming mode NOTE The system will automatically exit this mode after 60 seconds 14 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated the siren will NOT sound and no alarm condition will be reported EXAMPLE You wish to know when someone enters or exits the front door the keypad will beep each time the door is opened if that zone is programmed as a chime zone IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 23 14 1 To Program the Chime Zones 2 ZONE NUMBER ch Hold down the 2 key until the keypad buzzer sounds 2 The AWAY indicator will flash to show that the panel is In the chime zone programming mode 3 To program a zone as a chime zon
16. ee Arm Remote Control see Keyswitch Reporting Gode etnia edendo cerae aei 5 28 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 Veri EE 8 13 16 17 26 Stay Arm see Arm Stay Arm amp Go see Arm Slay ee M 7 11 Stay Profile esssssssssseseseeeneeen nennen 2 11 12 SOD Ci eL p 16 T REI e 9 16 19 25 TESUNG 6 Trouble Condition seseseeeeenenenenn 7 8 24 25 Trouble MOG PATERET ETT 25 Trouble Status ccccccccccccecccccceccesceeseceeececesceeeseseseeseeaeeeusaeaeaeaeaeanaes 2 U User CodeS iiinis di ei d nni itd ein ri dius 9 10 12 13 14 15 16 Z Zones Enty EE 5 8 10 13 14 26 Follower 5 8 10 13 14 26 Istant ee cL PEE 5 26 Push to Arm 2 ccccccccccscesssseseeececeeeceaeeeasseceeeeeeeeeseeaaeeeseeeeeeeeeeeas 8 10 SLAY EE 2 5 11 12 13 21 22 23 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 29
17. f the protected area while the System is armed Zones cannot be bypassed once the system is armed Bypassed zones are automatically cancelled each time the system is disarmed and must be re bypassed before the next arming e Zei Li Zei 6 1 To Bypass a Zone x ZONE NUMBER 1 Press the x key while bypassing zones violated zones will be flashing 2 Pressthe number corresponding to the zone you need to by pass e g the 2 key if you wish to bypass zone 2 3 Therelevant zone indicator will illuminate to indicate that the zone 14 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 is now bypassed 4 Repeat steps 1 and 2 to bypass any other zones NOTE Some zones may be programmed to function in a manner which does not permit bypassing e g Panic zones 6 2 To Un Bypass a Zone ZONE NUMBER 1 Press the x key 2 Press the number corresponding to the currently bypassed zone 3 The zone indicator will extinguish the zone is now active 7 Disarming the System 7 1 Disarming with a User Code USER CODE To disarm the system enter a valid USER CODE before the expiry of the entry delay Although not essential it is recommended that the key be pressed before entering a user code as this clears any unintended key entries Enter the premises through a designated entry exit door Enter ing via any other route will ca
18. gnored To deactivate the system Fire medical and panic functions remain active while the system is disarmed A zone with a programmable time delay which allows the user to exit the premises after arming the system and time to get to the keypad after entering the armed premises This zone is generally the last exit point of the building and the first entry point i e the front door of a home A zone that may be temporarily violated during the exit delay period or after violation of an entry exit zone This allows the user access to disarm the system A Follower zone will behave as per an Instant zone if violated prior to the violation of an entry exit zone When the system is armed violation of an instant zone will immediately cause an alarm condition to be registered Arming that allows for certain preprogrammed STAY zones to be violated while the system is armed Arming that allows the user to STAY ARM and leave the premises Zones which are bypassed automatically when the system is STAY ARMED A specific area of your premises guarded by sensors which detect violations of that area IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 5 1 Introduction to the IDS805 The IDS805 Control Panel is manufactured to the highest specification and will provide many years of service if correctly installed and main tained The unit is designed for simple operation yet provides the maximum protection for you your fa
19. mily or business For trouble free operation please follow the instructions contained in this User Manual Your security system consists of a control panel one or more key pads and various sensors and detectors An enclosure will contain the control panel which includes the system electronics fuses and stand by battery There is normally no reason for anyone other than the installer or service professional to have access to the control panel 1 1 Notes Read the entire manual carefully and keep it in an accessible place Your security system should be installed and serviced by a qualified security professional who should instruct you regarding the level of protection provided and the operation of the system Should you have any questions regarding the operation of the System contact your security company representative Z Your system should be tested on a regular basis Before testing the system please notify your security company of your intention to do so NEVER disconnect the mains power as the back up battery will eventually discharge thereby causing the control panel to shutdown Asecurity system cannot prevent emergencies It is only intended to alert you and if included your central station of an emergency situation Smoke and heat detectors may not detect all fire situations 6 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 2 Understanding the Keypad Indicators
20. ones that are bypassed 5 4 Quick Stay Arming 5 Hold down the key until the keypad buzzer sounds It is possible to STAY arm by holding down the 5 key until the keypad beeps There is no exit delay 5 5 Stay Arm and Go 6 Hold down the key until the keypad buzzer sounds 12 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 This is a quick function which allows the user to STAY arm and leave the premises 1 Hold down the 6 key until the keypad buzzer sounds The keypad buzzer will now sound on and off for the duration of the exit delay 2 Atthe end of the exit delay the ARMED indicator will illuminate and the AWAY indicator will remain extinguished Any stay zones will be bypassed 3 Be sure to leave only via the follower and entry exit zones 5 6 Arming from a Key Switch or Remote Control There are several option related to this function Verify with your installer which of the following have been installed Key Switch or Remote Control installed Exit Delay with Key Switch or Remote Control Siren toot on Arm Siren on toot Disarm 0 O D O Ensure that the READY indicator is illuminated before leaving Leave and close the door remembering to lock Press the remote button or twist and release the key switch The alarm will arm immediately and the remote ARM indicator will illuminate OR If an exit delay has been enabled the exit delay will begin 5 If
21. passed automatically when the system is STAY ARMED To avoid triggering the alarm zones such as bedrooms or other areas which require access must be bypassed Stay zones need only be programmed once Each time the System is armed in the stay mode the preselected stay zones will be bypassed automatically 12 1 To Program Stay Zones 3 ZONE NUMBER 4 1 Hold down the 3 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is in the Stay Zone programming mode 2 Pressthe NUMBER corresponding to the zone you wish to be a STAY zone followed by the x key 3 Therelevant zone indicator will illuminate Buzz zones will be shown by flashing indicators See Section 13 A Buzz zone cannot be selected as a Stay zone the Buzz status must be cleared first 4 Repeat step 2 until all stay zones are selected IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 21 4 Press the key to exit the stay zone programming mode 12 2 To Cancel the Stay Zones 3 ZONE NUMBER bla If an area programmed as a STAY zone will no longer be violated during STAY arming then the STAY status of such a zone should be cancelled This will allow the system to protect that area during a stay arm cycle 1 Ensure that the READY indicator is illuminated 2 Hold down the 3 key until the keypad buzzer sounds The AWAY indicator will flash to show th
22. programmed to do so the siren will sound briefly verify with your installer qu qus NOTE If a remote control is used it is advisable to have the siren sound on arm and disarm function enabled 5 7 Auto Arming Your system can be programmed to automatically arm itself daily at a preprogrammed time Ask your installer to program this function if required Should the premesis be occupied at the auto arming time a valid USER CODE entered during the 3 minute arming cycle will cancel the process IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 13 5 8 Arming with Entry exit or Follower Zones Violated The system can be programmed to arm even if the entry exit or follower zones are violated Follow the normal arming procedures i e Enter a valid USER CODE but it is not necessary to close the front door 5 9 Forced Arming If so programmed the panel can be armed even if there are violated zones This means that a monitored window can be left open or other zones can be violated and the panel will still arm If the violated zone is then cleared the panel will resume monitoring the zone hence causing an alarm condition or initiation of entry delay as appropriate if violated 6 Zone Bypassing The term BYPASS is used to describe a zone that has been de activated i e violation of a bypassed zone will not cause an alarm ltis used when access is needed to part o
23. to show that the keypad is in the TROUBLE viewing mode Refer to the table below to find the significance of each illuminated zone LED The system will automatically exit the TROUBLE mode after ten seconds To clear the trouble condition press within 5 seconds of viewing To simply cancel the beeping without viewing the trouble conditions press Indicator Trouble Condition 2 Failure to communicate to monitoring company 3 Mains power failure 4 Low battery 5 The Telephone line has been cut or is not present 6 The siren wire has been cut or the fuse has blown 7 Keypad has experienced a tamper 8 Installers code must be entered to clear an alarm condition N B If the zone 8 LED is illuminated contact your alarm installer immediately Until an installer code has been entered the system will NOT arm 15 2 Problems When Arming the System Is the code correct If you enter the wrong user code the keypad will beep three times and the system will not arm Is the READY Indicator illuminated If this indicator is not illuminated one or more zones are violated A violation is shown by a flashing zone indicator Ensure that all monitored doors and windows are closed Bypassing a violated zone IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 25 will also create a READY condition Does the installer need to reset the system Hold down the 7 key until the keypad buzzer sounds
24. ult is 1234 followed by the x key 4 The ARMED and READY indicators will begin to flash simultaneously indicating that the correct master code was entered If an invalid code was entered the keypad buzzer will beep three times 5 Enter the USER CODE NUMBER you wish to change 1 15 followed by the x key 6 Enter the new 4 digit USER CODE and press the x key 7 Repeat steps 5 6 to enter or change other user codes 8 Once all the codes are programmed press the key to exit 11 2 Deleting User Codes Follow steps 1 5 of the previous procedure but only press the x key in step 6 That particular code will be deleted 20 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 11 3 Maids Code The maids code user 14 may be used to limit access to the premises The maids code will only disarm the system if the same code was used for arming If armed with a code other than a maids code the system will view an attempt to disarm with the maids code as an invalid entry Any valid user code will disarm the system if it has been armed with the maids code EXAMPLE If a maid is expected on a Monday arming the system on a Monday morning using the maids code will allow the maid to disarm the system On days that any other user code i e not a maids code has been used to arm the system entering the maids code will not disarm the system 12 Stay Zones Stay zones are those zones which are by
25. use an alarm As soon as the entry exit zone is violated i e the door has been opened the entry delay begins The keypad buzzer will sound for the duration of the entry period to indicate that a valid user code is required Ifthe ARMED indicator remains illuminated an error was made while entering the user code press the key and re enter the code Once the system disarms the ARMED indicator will extinguish and the keypad buzzer will stop sounding If no valid user code has been entered by the end of the entry delay period an alarm condition will be registered IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 15 Ifthe entry period is too short have your installer change the entry delay period If four incorrect user codes are entered consecutively while either arming or disarming the system the keypad will be non responsive for 30 seconds Your monitoring company will also be notified on a keypad tamper NOTE If the ARMED indicator is flashing upon entry there has been a violation The intruder may still be inside Call for assistance NOTE If a strobe or flashing light has been installed and an alarm condition is registered the light will continue flashing after the siren has stopped sounding Entering a valid USER CODE will cancel the strobe 7 2 To Disarm with a Key Switch or Remote Control 1 Press the remote button or twist and release the key switch 2 The s
26. will be displayed for five seconds 7 The zone bypassed memory will only be erased if the key is pressed while the memory is being displayed 10 3 Zone Tamper Memory The Zone Tamper Memory displays any zones where a tamper condition has occurred To Display Zone Tamper Memory 0 then 2 1 Hold down 0 until the keypad buzzer sounds 2 The READY indicator will extinguish and the keypad buzzer will sound briefly 3 Flashing zone indicators show which zones were violated during the last armed cycle 4 To view any tampered zones press the 2 key once IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 19 5 Zonesthathave registered a tamper condition will have flashing indicators 6 Thememory status will be displayed for five seconds 7 The zone tamper memory will only be erased if the key is pressed while the memory is being displayed The IDS805 Alarm Panel has 15 programmable user codes Code 1 Master User Code Code 2 13 General User Codes Code 14 Maids Code Code 15 Duress Code 11 1 Entering New and Changing Existing User Codes MASTER USER CODE CODE NUMBER x NEW CODE 1 Hold down the x key until the keypad buzzer sounds 2 The ARMED and READY indicators will flash alternately indicating that the system is in the mode which allows programming of user codes 3 Enter the MASTER USER CODE the factory defa
27. ystem will disarm and the remote indicator if installed will extinguish 3 If programmed to do so the siren will sound briefly verify with your installer 8 Emergency Situations 8 1 Fire Alarm F Hold down the key until the keypad buzzer sounds Ifthe F key is pressed until the keypad beeps approximately 1 second a FIRE ALARM condition will be activated The FIRE ALARM CONDITION can also be triggered by a smoke detector connected to an appropriately programmed zone The siren will sound and the FIRE REPORTING CODE will be transmitted to the monitoring company Tosilence the siren enter a 4 digit USER CODE The siren will stop sounding after 10 minutes if no user code is entered 16 IDS805 USER MANUAL NO 700 266 01A ISSUED NOV 2003 VER 1 00 8 2 Panic Alarm P Hold down the key until the keypad buzzer sounds If the P key is pressed until the keypad beeps approximately 1 second a PANIC ALARM condition will be activated A PANIC ALARM can also be activated by any FIXED PANIC or REMOTE PANIC buttons which may have been installed If audible panic option has been selected the siren will sound A PANIC REPORTING CODE will be transmitted to the monitoring company To silence the siren enter a valid 4 digit USER CODE If the siren is not cancelled it will stop automatically after the programmed SIREN TIME OUT period Ensure that your installer has enable

Download Pdf Manuals

image

Related Search

Related Contents

Philips Digital PhotoFrame SPF1137B  Weider WG8225 User's Manual  イナバ物置 組立説明書 【N65】  BoConcept Model 2200 Assembly Instruction  INSTALLATION MANUAL Network Adapter for Air  BENDIX PNU-164 User's Manual  Equip Triple Socket with USB Car Charger  Bianchi BVM581-BVM551  

Copyright © All rights reserved.
Failed to retrieve file