Home

S4 User Manual CE 0107.book - Pdfstream.manualsonline.com

image

Contents

1. JUICE FOUT CE User Manual Production Dates September 2004 Present Copyright 2007 Electronic Theatre Controls Inc All Rights reserved Product information and specifications subject to change Part Number 7060M1210 06 01 Rev A Released August 2007 Table of Contents Declaration of conformity LL 1 Source Four CE guidelines 2 Basic luminaire seris uar eg sr 3 Luminaire information o 4 Colour frame holder 5 Replacing the HPL lamp 6 Centering lamp and adjusting the field 7 Focusing the beam 7 Shaping the beam 8 Rotating the barrel assembly 9 Adjusting the yoke position 0 000 eee eee 9 Cleaning lens and reflector 000 c eee eee 10 Portable appliance test PAT guidelines 12 ETC Emphasis Expression Insight Imagine Focus Express Unison Obsession Il ETCNet2 EDMX Source Four Revolution Sensor and WYSILink are either registered trademarks or trademarks of Electronic Theatre Controls Inc in the United States and other countries All other trademarks both marked and not marked are the property of their respective owners English Declaration of conformity C C TOV Rheinland A Gs We Electronic Theatre Controls Europe Ltd declare under sole responsibility that the product Product name Source Four CE Product type model Source Four CE series 405 410 414 419 426 436 45
2. Lamp socket assembly Retainer bolt Drop in iris slot Retainer bolt gt Colour frame FT Reflector housing Yoke locking knob eflector Gel retainer clip XSS Barrel rotation knob Shutters Gobo holder slot Uf Beam focus knob dX Colour frame holde Safety screen 19 26 36 and 50 onl i 19 26 36 and 50 only Figure 1 WARNING Please note the following safety warnings before use Do not mount the luminaire on or near combustible surfaces Do not operate the luminaire without a lens installed Always hang the luminaire with the colour frame retaining clip in the locked position English Luminaire information Wiring and power information A plug of at least 2 5 amp 220 240V rating should be attached to the luminaire s mains lead The wires in the mains lead are 1 55mm each and coloured in accordance with the following code Green and Yellow Earth Blue Neutral Co Brown Live WARNING This luminaire must be earthed Current rating 120V 5 amp maximum 240V 2 5 amp maximum Operating frequency 50 60 Hz HPL lamp table CAUTION Do not use lamps other than the HPL in Source Four fixtures Use of lamps other than HPL will void your warranty Lamp code Watts Volts Initial Lumen Colour Average rated life temp HPL 750 230 750 230 19 750 3 200 K 300 hours HPL 750 230X 750 230 15 600 3 050 K 1500 hour
3. best adjustment Rear lamp Inner Knob housing peak flat field adjustment Hot spot lamp pulled out too far Field with hole lamp Outer Knob lamp pushed in too far center adjustment Figure 4 Figure 5 The two concentric knobs located on the lamp housing allow you to align the lamp and adjust its field See Figure 4 The outer knob centers the lamp within the reflector The inner knob adjusts the lamp s field Step 1 Turn on the Source Four CE and aim it at a flat surface Adjust the barrel to create a hard edge Step 2 Unlock and loosen the outer knob by turning it counterclockwise Step 3 Gently move the outer knob from side to side and up and down until the lamp is centered within the reflector Step 4 Once the lamp is centered turn the outer knob clockwise to lock it in place Step 5 Finally turn the inner knob either clockwise or counterclockwise to achieve an optimum flat field See Figure 5 Focusing the beam Beam focus knob Figure 6 Step 1 Loosen the beam focus knob located under the barrel as shown in Figure 6 Step 2 Slide the lens tube forward or backward to achieve the desired beam edge Step 3 Once the luminaire is focused tighten the beam focus knob English Shaping the beam The beam can be shaped using the shutters see Figure 8 a gobo an optional drop in iris or by rotating the barrel Gobo Projection The gobo holder slot is on the top side of the barrel and in front of the
4. 0 470 490 Lot n a Batch Serial number n a Item numbers one of each model to which this declaration relates in conformity with the following standards EN60598 1 2000 Luminaires General requirements and tests EN60598 2 17 1990 Specification for luminaires for stage lighting television film and photographic studios outside and indoor equiv BS 4533 102 17 1990 following the provisions of EU LV Directive s 73 23 EEC London United Kingdom Mr Adam Bennette Place of issue Name of authorised person ud n 07 AA Date of issue signature of authorised person Electronic Theatre Controls Ltd Registered office Unit 26 28 Victoria Industrial Estate Grant Thornton House Victoria Road London W3 6UU U K Melton St London NW1 28W England Telephone 44 0 20 8896 1000 Registered in England No 3057796 Fax 44 0 20 8896 2000 VAT No 6629487 90 English Source Four CE guidelines The Source Four CE is intended for professional use only Read the entire User Guide before using equipment WARNING Please note the following safety precautions Do not mount the Source Four CE on or near a flammable surface Use the Source Four CE in dry locations only where humidity does not exceed 90 percent e The luminaire is for indoor use only and is not intended for outdoor use e For temporary installations mount and support the Source Four CE only by the primary suspension yoke holes Suspe
5. Yoke locking knob Figure 11 Step 1 Loosen the yoke locking knobs see Figure 11 Do not remove them Step 2 Tilt the luminaire to the desired position Step 3 Tighten the yoke locking knobs to secure in position Cleaning lens and reflector WARNING Do not use ammonia based or other harsh commercial cleaners Clean lenses and reflector only as directed Commercially available glass cleaning agents should be avoided as they may contain ammonia other harsh chemical detergents or abrasive agents These cleaners may damage the glass surface and the Anti Reflective coatings Do not immerse or soak the glass in any cleaning solution Replace lenses if they contain visible damage cracks or deep scratches that may impair their effectiveness Cleaning 14 19 26 36 50 70 90 and all EDLT glass lenses Step 1 Remove the beam focus knob along with retainer bolt and collar from the barrel see Figure 1 Remove the lens tube from the barrel Note To clean the inside of lenses it is necessary to remove the lenses from the lens tube for cleaning Instruction for removing the lens can be found in the Source Four Assembly Guide available for download at our website www etcconnect com Step 2 Remove dust with a blast of oil free air or wipe with a clean lint free cloth Isopropyl alcohol distilled water or a 50 50 mixture of each can be used to clean the glass surface Step 3 Slide the lens tube back i
6. ariety of heat shield products is also available from many colour media manufacturers Follow the manufacturer s instructions for the use of these products For maximum gel life with specific lens tubes refer to the tables below Lens Tube Soft Focus Back Sharp Focus Soft Focus Forward Soft Focus Forward Lamp flat Lamp cosine Lamp peak Lamp cosine 14 worse good best good 70 best good worse good 90 best good good worse 19 worse better better not applicable 26 worse better better not applicable 36 better better worse not applicable 50 worse better better not applicable ED Lens Tube Soft Focus Back Sharp Focus Soft Focus Forward Soft Focus Forward Lamp flat Lamp cosine Lamp peak Lamp cosine 19 worse better better not applicable 26 better better worse not applicable 36 better better worse not applicable 50 better better worse not applicable English Replacing the HPL lamp ay it ___ HPL lamp Lamp retention brackets Lamp retaining clips Knurled bolt Figure 3 A lamp must be installed before you use the luminaire Note Verify that the HPL lamp you intend to install is suitable for your facility s voltage 115 120 230 and 240 volt HPL lamps are available See HPL lamp table page 4 Operating HPL lamps above their rated voltage reduces lamp life a
7. e iris handle Step 5 Secure the drop in iris slot cover by tightening the screws Rotating the barrel assembly N Barrel rotation knob y dd ND Nu Figure 9 Step 1 Loosen the barrel rotation knob directly behind the shutters on the underside of the reflector housing see Figure 9 Do not remove the barrel rotation knob Step 2 Rotate the barrel to the desired position up to 25 in either direction from the centered position Step 3 Once the barrel is positioned tighten the barrel s rotation knob to lock it in place Adjusting the yoke position The Source Four CE provides multi positioning capabilities within its yoke for overall luminaire height and angle ht within the yoke The Source Four CE has a two position yoke for modifying the overall height in which the luminaire is mounted see Figure 10 To change the height position perform the following steps Setting the luminaire hei General use position ASK e Low clearance position Figure 10 Step 1 Remove the yoke locking knobs washers and hex bolts from either side of the luminaire Step 2 Raise or lower the luminaire to the desired position within the yoke Step 3 Reinstall the yoke s hex bolts washers and locking knobs Step 4 Tighten the yoke knobs to secure in position English Setting the angle within the yoke
8. el frame retainer on top Reinstall beam focus knob Cleaning the reflector WARNING Unplug the fixture before attempting to clean the reflector To quickly clean the reflector remove the lens tube and clean the dust from the reflector with a blast of oil free air You may also wipe the reflector with a clean lint free cloth If either method is not sufficient follow these steps Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 To protect the lamp housing during cleaning remove the lamp housing by loosening the knurled bolt and pulling the housing straight out See Figure 3 Remove the barrel rotation knob located at the bottom of the barrel see Figure 1 Use a Phillips screwdriver to remove the retainer bolt located on top of the reflector housing Rotate the barrel 45 in either direction Carefully remove the barrel from the reflector housing Remove dust with a blast of oil free air or wipe with a clean lint free cloth Isopropyl alcohol distilled water or a 50 50 mixture of each can be used to clean the glass surface Insert the barrel into the reflector housing with the iris gobo slot on top Align the triangles on both parts While gently pressing in rotate the barrel 45 clockwise until it sets into position then rotate the barrel counterclockwise 45 The barrel should be firmly attached and the triangles should be aligned Reinstall the barrel rotation knob and tighten the
9. nd can cause premature lamp failure WARNING Let the lamp cool before replacing Step 1 Disconnect power to the Source Four luminaire before installing the lamp Step 2 Loosen the knurled bolt on the back of the lamp housing and pull the housing out Step 3 Holding by the base remove the HPL lamp from its box CAUTION Use caution when installing or replacing any lamp When installing replacing lamp be sure to point the lamp away from your face and away from others before inserting it firmly into the assembly This may prevent injuries if the lamp should break INCORRECT da CORRECT Note To avoid premature lamp failure do not touch the lamp glass If you do clean it carefully with isopropyl alcohol and a clean lint free cloth Allow to dry before operation Step 4 Align the flat sides of the lamp base with the retention brackets on either side of the socket as shown in Figure 3 Step 5 Push down on the lamp base until the lamp seats firmly When properly installed the top of the lamp s base will be even with he top edges of the retention brackets CAUTION Improperly installed lamps cause premature lamp failure and socket problems Step 6 Press lamp retaining clip across lamp base to secure Step 7 Reinstall the lamp housing by aligning the bolt hole and tightening the knurled bolt Source Four CE User Manual English Centering lamp and adjusting the field Flat field
10. nd the luminaire from a hook clamp or a stand mount using a securely tightened steel bolt up to 12 mm flat washer and locking washer e In addition to primary suspension attach a safety cable ETC part 7060A1022 or chain to the secondary suspension point on the Source Four CE Ifthe external cable is damaged it shall be replaced by ETC or our service agents e Always hang the Source Four CE with the colour frame held securely behind the retaining clip Always replace the lamp if it becomes damaged or thermally deformed e Disconnect the unit from power before all cleaning and maintenance e The Source Four CE is suitable for indoor use with a maximum ambient temperature T 45 C e Maximum exterior surface temperature T max 217 C Amultilingual label sheet is included with this manual Affix the label of the appropriate language over the existing warning label on the extension yoke Do not cover ETC trademark or CE mark e The Source Four CE is equipped with a safety screen that covers the lens to prevent injury from broken glass due to lamp failure Do not remove this safety screen e Keep the luminaire at least 0 8 meters away from any lit surface Lighted objects at this distance or greater will not exceed 90 C temperature from projected light 2 Source Four CE User Manual English Basic luminaire Earth continuity cable Secondary suspension point Primary suspension yoke mounting holes
11. nto the barrel with the color frame retaining clip on top Reinstall the beam focus knob retainer bolt and collar Cleaning 5 and 10 polymer lenses To quickly clean the lenses remove dust with a blast of oil free air If this is not sufficient follow these steps CAUTION Handle polymer lenses by their edges only Never rub anything dry on a polymer lens Source Four CE User Manual English Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Remove the beam focus knob at the bottom of the barrel see Figure 1 Remove the lens tube from the barrel Use a Phillips screwdriver to remove the brackets that hold the lens in place Remove the lens from the tube Dip the lens in a clean isopropyl alcohol water mixture 9 parts water to 1 part isopropyl alcohol Use a soft moistened nylon bristle brush to wash the lens smooth side in a linear non circular motion Use the same brush to lightly wash the lens ridged side by following its ridges Dip the lens in a clean isopropyl alcohol water mixture 9 parts water to 1 part isopropyl alcohol Dry the smooth and ridged surfaces with an air gun Make sure the air flow moves liquid away from you Inspect the lens for dirt Repeat steps 3 7 if necessary Set the lens back in the lens tube with the ridged side facing the front of the tube Reinstall the lens brackets Slide the lens tube back into the barrel with g
12. oad Kowloon Bay Kowloon Hong Kong m Tel 852 2799 1220 m Fax 852 2799 9325 Service Americas service etcconnect com m UK service etceurope com m DE techserv hoki etcconnect com w Asia service etcasia com Web www etcconnect com m Copyright 2007 ETC All Rights Reserved m Product information and specifications subject to change 7060M1210 06 01 m Rev A m Released 08 2007
13. retainer bolt Reinstall the lamp housing and tighten the knurled bolt English Portable appliance test PAT guidelines The Portable Appliance Test is a set of tests that must be administered to electrical equipment in the UK and some locations in Europe to ensure safety The tests are typically carried out using a small PAT device The PAT device connects to a power source and then attaches to the product via an electrical outlet and test probes The PAT provides a simple pass or fail result allowing rapid testing of large inventories Source Four CE luminaires include a specific PAT point where the test clip is attached as shown in Figure 12 PAT tests should be performed by a qualified technician Your local regulatory authority has guidelines on the testing frequency PAT device po point Figure 12 12 Source Four CE User Manual English delle Corporate Headquarters 3031 Pleasant View Road P O Box 620979 Middleton Wisconsin 53562 0979 USA m Tel 608 831 4116 Fax 608 836 1736 London UK Unit 26 28 Victoria Industrial Estate Victoria Road London W3 6UU UK m Tel 44 0 20 8896 1000 m Fax 44 0 20 8896 2000 Rome IT Via Ennio Quirino Visconti 11 00193 Rome Italy Tel 39 06 32 111 683 m Fax 39 06 32 656 990 Holzkirchen DE Ohmstrasse 3 83607 Holzkirchen Germany m Tel 49 80 24 47 00 0 Fax 49 80 24 47 00 3 00 Hong Kong Rm 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet R
14. s HPL 575 230 575 230 14 900 3 200 K 400 hours HPL 575 230X 575 230 11 780 3 050 K 1500 hours HPL 375 230 375 230 7 250 3 000 K 1000 hours HPL 750 2240 750 240 19 750 3 200 K 300 hours HPL 750 240X 750 240 15 600 3 050 K 1500 hours HPL 575 240 575 240 14 900 3 050 K 400 hours HPL 575 240X 575 240 11 780 3 050 K 1500 hours HPL 375 240X 375 240 19 750 3 000 K 1000 hours Source Four CE User Manual English Colour frame holder Figure 2 The colour frame holder is equipped with a spring loaded retaining clip that prevents colour frames and accessories from falling out See Figure 2 WARNING Make sure all colour frame accessories are locked in position with the retaining clip before hanging the Source Four luminaire Step 1 Release the retaining clip by pushing it sideways while gently pulling backwards Step 2 Insert the colour frame Step 3 Lock the retaining clip by pushing sideways while gently pushing forward Note The performance of saturated colours may be less than desirable in any theatrical lighting luminaire especially when equipped with a 750w lamp For best results always use high quality colour media rated for high temperature use ETC s optional Conical Gel Extender part 7060A1048 will provide maximum colour media life For 14 lens tubes use part PSF1029 Gel Extenders are not recommended for 70 and 90 lens tubes due to the extremely wide angle beam A v
15. shutters It accommodates A size B size and glass gobo holders see Figure 7 A Size Gobo holder holds faz em diameter gobos B Size Gobo holder holds 6 35 cm and 6 98 cm diameter gobos 7 92 cm Diameter gt lt 6 98 cm Diameter Figure 7 Note Because the Source Four luminaire aperture is 7 62 cm wide ETC recommends using A size gobos for maximum effectiveness Note Enhanced Definition Lens Tubes EDLT provide for a crisper gobo projection Use an optional donut in the accessory holder to enhance gobo projection Donut diameter range should be 6 35 cm to 6 98 cm Drop In Iris Slot Shutters Drop in iris slot Figure 8 The drop in iris slot is located on the top of the barrel and in front of the gobo holder slot It accommodates either a drop in iris or a motorized gobo device When the slot is not in use a small sheet metal cover secured with two Phillips screws prevents light leakage see Figure 8 Step 1 Use a Phillips screwdriver to loosen the screws on the drop in iris slot cover Do not remove screws Step 2 Slide the cover completely forward to expose the slot Source Four CE User Manual English Step 3 Insert the iris or motorized gobo device For an iris install the flat side toward the shutters and make sure the iris handle extends from the slot Step 4 Slide the slot cover back toward the shutters until it meets the iris handle Leave enough space to move th

Download Pdf Manuals