Home
Spec Sheet 7010 Series Page 1.ai
Contents
1. SMOKE ALARM PHOTOELECTRIC 7010 De Model 7010B He porh ar PHOTOELECTRIC Photoelectric technology is generally more sensitive at detecting large particles which tend to be produced in greater amounts by smoldering fires OPTIPATH 360 TECHNOLOGY Provides 360 degrees of direct access to the smoke sensing chamber SINGLE BUTTON TEST SILENCE Silences and tests alarm with a single button TWO LOCKING FEATURES Pins are provided to lock battery drawer and or alarm to base Perfect for apartment dormitory or hotel applications Available in the following versions 7010 AC Alarm with silence 7010B AC Alarm with silence and battery backup Listed to UL 21 Standard THE PROFESSIONAL STANDARD 120V AC 60Hz Wire in with 9V Battery Backup 7010B Description The BRK Brands Inc Model Numbers 7010 and 7010B are wire in 120V AC 60Hz single and or multiple station photoelectric smoke alarms specifically designed for residential and institutional applications including sleeping rooms of hospitals hotels motels dormitories and other multi family dwellings as defined in standard NFPA 101 Models 7010 and 7010B comply with UL217 CSFM NFPA 72 HUD FHA and other agencies that model their codes after the above agencies They meet building codes where AC and AC DC with silence photoelectric smoke alarms are required The alarms are interconnectable with up to 18 devices of which 1
2. 2 can be smoke alarms The BRK 7010 Series alarms feature a photoelectric smoke sensing chamber an 85dB horn a 9V battery back up model 7010B only and a silence feature Optipath 360 technology provides 360 degrees of direct access to the smoke sensing chamber The Perfect Mount system features a gasketless base and a mounting bracket that keeps the alarm secure over a wide rotation range to allow for true alignment This will allow fine tuning on the positioning to compensate for out of aligned wall studs and to keep the wording level when wall mounting Battery installation and removal can occur while the unit is mounted to the ceiling or wall via the side load battery compartment Other Contractor Preferred features include a dust cover to keep alarm clean during construction keyhole slots in the mounting bracket eliminate the need to remove the electrical box screws for installation Two locking features are provided to prevent battery theft and or theft of the unit Connection to AC power is made with a Quick Connect wiring harness Installation is quick easy and cost effective 7010 Series MOUNTING TOP VIEW BRACKET SIDE VIEW 5 0 The smoke alarm shall be a BRK Model 7010B battery backup or 7010 no battery backup and shall provide at a minimum the following features and functions 1 A photoelectric smoke sensing chamber 2 The unit shall be capable of self restoring 3 Fully scree
3. ED flashes rapidly Remote Alarm Red LED out Listing Listed to UL217 Standard Individual Carton Dimensions 5 13 L x 2 38 W x 5 13 H Weight 0 45 Ibs 7010 0 55 Ibs 7010B Cube 0 04 ft3 UPC 0 29054 11200 2 7010 0 29054 11201 9 7010B Master Carton Dimensions 10 75 L x 7 88 W x 11 06 H Master Pack 12 Weight 5 9 Ibs 7010 7 1 lbs 7010B Cube 0 54 ft3 20f5 7010 100 29054 11200 9 7010B 100 29054 11201 6 Pallet Information Cases per Layer 22 Number of Layers 4 Cases per Pallet 88 Units per Pallet 1 056 Cube 54 0 ft3 Weight 572 Ibs 7010B 678 Ibs 7010B 2009 BRK Brands Inc a Jarden Corporation Company NYSE JAH 3901 Liberty Street Road Aurora IL 60504 8122 All rights reserved First Alert is a registered trademark of the First Alert Trust a is a registered trademark of BRK Brands Inc THE PROFESSIONAL STANDARD brkelectronics com
4. nd be rated at least 300V It is recommended that all units be on the same fuse or circuit breaker If local codes do not permit be sure the neutral wire is common to both phases THE PARTS OF THIS SMOKE ALARM Mounting bracket Mounting Slots Locking Pins Hot Black AC Wire Nuetral White AC Wire Interconnect Orange Wire Pull out Battery Drawer Quick Connect Plug WN Soe Gh A Unswitched 120VAC 60 Hz source B To additional units Maximum 18 total Maximum 12 Smoke Alarms 5 Junction Box 6 Neutral Wire White 7 Interconnect Wire Orange 8 Hot Wire Black Smoke Alarm Ceiling or Wall Power Connector Wire Nut Alarm Dimensions 5 0 dia x 2 1 H Weight 6 7 0z 7010 8 4 oz 7010B Operating Voltage 120V AC 60Hz w 9V battery backup 7010B only Operating Current 045 amps standby alarm Temperature Range 40 F 4 C to 100 F 38 C Humidity Range 10 to 90 relative humidity RH Audio Alarm 85dB at 10 feet Test Silence Electronically simulates smoke condition causing the unit to alarm Press and hold test silence button Automatic when smoke clears Up to 18 units of First Alert or BRK Smoke CO and Heat Alarms Maximum of 12 smoke alarms See user s manual for details Photoelectric Alarm Reset Interconnections Smoke Sensor Indicator Lights Sounds AC Power Constant Green LED DC Power Intermittent Red LED 7010B only Local Alarm Red L
5. ned sensing chamber to resist entry of small insects thereby reducing the probability of unwanted alarms 4 Powered by 120V AC 60Hz and have a monitored 9V battery backup model 7010B only and a solid state piezo horn rated at 85dB at 10 ft 5 A visual green LED power on indicator to confirm unit is receiving power or is in alarm 6 A full function test button should check all alarm functions by simulating a smoke condition causing the unit to alarm 7 Silence feature Temporarily silence unwanted nuisance alarms 8 Two Locking features tamper resistant locking pins that lock battery drawer and or alarm to mounting bracket 9 The unit shall be capable of operating between 40 F 4 C and 100 F 38 C and relative humidity between 10 and 90 10 The unit shall have a gasketless base for easy installation and be capable of keeping alarm secure over a wide rotation range to allow for true alarm alignment 11 The unit shall have a plug in connector and be capable of interconnection of up to 18 alarms 12 of which can be smoke alarms 12 The unit shall ata minimum meet the requirements of UL217 CSFM NFPA 72 NFPA 101 ICC Installation of this smoke alarm must conform to all local electrical codes and Article 760 of the National Electrical Code NFPA 70 B and NFPA 72 Interconnected units must meet the following an requirements Total length of wire interconnecting units should be less than 1000 feet be 18 gauge or larger a