1. Please wait while installation program is formatting the disk partition on The system displays the progress bar of formatting After the installation program formats the new partitions it will prompt Please wait while installation program copies files to the Windows installation folders This might take several minutes to complete The system will display the progressive bar of document duplicating After the duplication of document take out the driver floppy or disconnect Inspur driver U disk and the system will restart automatically 11 After the system restarts select to boot from hard disk Install wizard collects relevant information and prepares to install The installation program detects and installs the equipment and during the pro cess if prompts of software installation and hardware installation etc pop up click YES to continue After the completion the system will automatically take the next step 12 The system displays Regional and Language Options you can use different region and language to user define Windows If you need to change setup please click Custom button to configure according to demands It is suggested using the default setting and here click lt Next gt to continue the in 2 Chapter Five Install Operating System EE stallation 13 Personalize Your Software The installation program will self define your Windows software based on the personal information
2. Select image type to load If to load floppy disk image please select Floppy Im age And if to load CD image please select ISO Image then click Browse to select image location and click the corresponding Connect to complete loading image If it is bootable CD or system installation disk in CD drive of synchronous client set client CD drive as the first startup sequence in server BIOS settings Installation of ISO file is the same with remote CDROM installation which needs to set startup se quence in server BIOS F Remote desktop Keyboard Layout menu Menu Function Jane Detect Select this option and it will automatically detect the key board type SoftKeyboard Use soft keyboard There are keyboard types of many kinds of languages for choice G Remote desktop VideoRecord menu Slect VideoRecord menu to set options related with video record Menu Function Start Record Select this option and begin video record Stop Record Select this option and stop video record This option is used to set video record duration and stor Settings age directory Only after the directory is set can the video record begin H Help Help menu Click Help menu A drop down menu About JViewer appears Select this op tion and redirection browser version will display 2 Server Power Control menu Select Server Power Control menu and enter the interface shown in the following figure Chapter Six Instr
3. Hold Right Ctrl Key Select this option equal to click the Ctrl key of the right side when operating Hold Right Alt Key Select this option equal to click the Alt key of the right side when operating Hold Left Ctrl Key Select this option equal to click the Ctrl key of the left side when operating Hold Left Alt Key Select this option equal to click the Alt key of the left side when operating Left Windows Key Select this option will appear Hold down and Press and Release It stands for press down or release Windows key of the left side Right Windows Key Select this option will appear Hold down and Press and Release It stands for press down or release Windows key of the right side Ctrl Alt Del Select this option equal to press Alt Ctrl Del Notes when configuring RAID through remote console it needs the following three ways into the RAID configuration interface take combination keys Ctrl H for example D Check Hold Left Ctrl Key option in remote desktop Keyboard menu and then click key H on the Keyboard 2 Select key LCTRL at the lower right corner of remote desktop and then click key H on the Keyboard 8 Through SoftKeyboard in remote desktop Keyboard Layout menu click CTRL h on the soft Keyboard Chapter Six Instructions for Motherboard Management Controller HE C Remote desktop Mouse menu Video Keyboard Mouse Options Media
4. and there is abnormal array information then it is likely that the RAID card has set off the alarm There may be array abnormal ity when the hard disk back plane alarms there is always abnormal status light of the hard disk on the front panel which can be used to help analysis 3 After having collected the basic information please feedback the detailed alarm information to Inspur technical support personnel in a timely manner We will make further analysis and judgment and help you solve the problem as soon as possible 7 4 Additional Notes 1 In order to guarantee the reliability of the system it is suggested that you use the component of the relevant Model tested and authenticated by us when expanding and equipping components 2 Please guarantee the fine electricity utilization environment of the server nor Chapter Seven Common Problems and Trouble shooting mal voltage input and earth connecting condition and temperature and humidity and so on within the normal range 3 For special needs when transferring the server pay attention to avoiding the vibration and carry out in power off condition 4 For more notices of our products please refer to the FAQ for server in the of ficial website of Inspur http www inspur com support Channel_ Home support sv asp 7 5 Technical Support Information If you have any doubt or unsolved problems in using Inspur server please take the following measures 1 If you have doubt in p
5. select an unconfigured slot and press Add Role Network Bond Hoban Link Number of configured Role groups 0 Role Group ID Group Name gt NTP Group Privilege PAM Order PEF RADIUS Remote Session Services Modify Role Group l Delete Role Group SMTP Configuration menu is shown in picture above The following will introduce the commonly used menus CD Mouse mode menu set mouse mode Set Mode to Absolute Recommended when server OS is Windows the absolute mode mouse can switch freely between remote picture and local picture Set Mode to Relative Recommended when server OS is Linux the relative mode mouse can switch between remote picture and local picture by selecting lt Alt gt lt M gt 2 Network menu set network Please change IP address or select DHCP accord ing to needs 8 NTP menu set date and time to be synchronous with time server or set at will If the remote management needs to choose time server to be synchronization please input address of time synchronization server 4 Remote Session menu set KVM or data to be encrypted or not during the next Chapter Six Instructions for Motherboard Management Controller o time redirection as well as the loading method of virtual media 5 SMTP menu set SMTP server s IP address as well as user name and password 8 User menu set user And be able to add edit and remove users The username should start with English letters and have
6. to start the installation 4 Enter the interface of Welcome to the InstallShield Wizard click lt Next gt to continue Enter the interface of Ready to Install the Program click Install to install graphic card driver Setup begins to install and finish installation click Finish in the interface of InstallShield Wizard Completed and the system pops up window which prompts you need to restart the server to put the setup into effect Take all the disks out of the CD drive select lt Yes gt to restart the server 5 Install unknown device driver Enter Windows system right click the My computer icon then select Property item D In the system property select Hardware and open Device Manager 2 In the device manager select Unknown device in the Other device click the right button of the mouse and select Update Driver 3 The window Welcome to the Hardware Update Wizard will pop up If the system inquires Can Windows connect to Windows Update to search for software select No not this time and click lt Next gt 4 The window Hardware Update Wizard will be shown select Install from a list or specific location Advanced and click to continue Select Include this location in the search point to CD root directory driver IPMI nf5280M3 win03 32 put Inspur driver U disk into the CD drive click lt Next gt to continue and the system begins to aut
7. Keyboard Layout VideoRecord Help Zoom Size 100 Q as iv Show Cursor AIt C O Mouse Calibration Alt T Menu Function Select this option to display local mouse and redirection Show Cursor mouse on remote desktop at the same time D Remote desktop Options menu Video Keyboard Mouse Options Media Keyboard Layout VideoRecord Help Zoom Size 100 iz Q Bandwidth gt a m e 50 100 150 iv Keyboard Mouse Encryption Zoom Menu Function Bandwidth Select this option to set display bandwidth Keyboard Mouse Encryption Set keyboard mouse encryption Select this option to zoom in or zoom out re mote desktop display window Zoom In is to amplify display window and Zoom Out is to narrow display window Zoom E Remote desktop Media settings Click Media menu It will appear Virtual Media Wizard menu By this menu the user can load client side floppy disk image CD image and CD drive as is shown in figure below 1s0 mage a j Hard disk USB Key Media1 HD USB Image s Browse Connect Hard disk USB Key PhysicalDrive0 Z C D E F Fixed Drive Status Target Drive Connected To Read Bytes Virtual Floppy 1 Not connected nia Virtual CD 1 Not connected nla Virtual HardDisk 1 Not connected n a Chapter Six Instructions for Motherboard Management Controller
8. based on the ac tual demand RAIDO it allows 2 or more than 2 hard disks to form this RAID volume RAIDI it allows 2 hard disks to form this RAID volume RAID10 it allows 4 hard disks to form this RAID volume with 4 or more hard disks 22 Chapter Four SAS RAID Setup HE RAIDS Parity it allows 3 and more than 3hard disks to form this RAID volume Disks select hard disks to be used to form RAID volume select this option and press Enter key it will enter the hard disk selection interface please press Space key to select the hard disk in turn to form RAID volume and then press Enter key to return the menu interface of volume creation Strip Size please select the size of strip of volume and only volumes RAIDO and RAIDS can select this option Capacity Set the size of volume capacity which is defaulted as the maximum capacity Alter all the setting above have been done well please select Create Volume and press lt Enter gt the screen will display WARNING ALL DATA ON THE SELECTED DISKS WILL BE LOST Are you sure you want to create this volumes Y N If the creation of RAID volume is confirmed please enter Y the volume will then be created and at the same time all the data on the selected hard disk will be lost If not to create RAID volume please enter N and exit the creation of volume Here we enter Y and create RAID volume after the creation return to the main configuration i
9. begins to boot When Press DEL to SETUP or TAB to POST appears at the bottom of the screen please press DEL key The system will enter BIOS setup If the system does not enter BIOS setup after previous steps please press lt Ctrl gt lt Alt gt and lt Del gt at the same time to reset the system and repeat the previous steps If the prompt displays to press lt DEL gt again please press it quickly There are some items that cannot be set in BIOS for example some informa QD Chapter Three System Setup EN tion on system s automatic detection and configuration A right pointing signal may be found before some items which means this item is selected and press Enter gt the system will enter the cascading menus 1 e submenus 3 1 2 BIOS System Menu Introduction The following some main function menus in BIOS will be introduced in this section Menu name Menu function Main Configuring the basic system setup like the system time and date and displaying the information of BIOS Adaned Configuring advanced characteristics of CPU integrated ae SATA controller and others Configuring memory mode CPU feature and others Server Mgmt BMC information and management BMC Boot Configuring boot order of each device in the system Security Configuring the super user and user s password Save amp Exit Saving or exiting BIOS etc Operation key introduction For selecting the upper menu or
10. below Chapter Three System Setup EE Notes When clearing CMOS the system must be shut down and cut off the power sup ply Short cutting pin2 and 3 need to keep for 5 seconds then use the jumper cap to short cut pin 1 and 2 default settings of the CLR CMOS to restore the original state Chapter Four SAS RAID Setup o Chapter Four SAS RAID Setup This chapter mainly introduces the configuration of onboard SAS controller RAID and its application method If the server you purchased does not use onboard SAS RAID you can not refer to this chapter If you use onboard SAS RAID you need to enter BIO set the Chipset PCH SCU devices item to Enabled and then set Onboard SAS Oprom item to Enabled 4 1 How to Enter the Configuration Interface of SAS RAID 1 During boot the screen will display Press CTRL I to enter Configuration Utility 2 Press Ctrl I to enter SAS RAID configuration interface 4 2 Control Key Application Key Description fH For moving cursor and modifying menu option value in differ ent menus For selecting the next menu configuration items For selecting menu For exiting menu or back to the previous menu from submenu 4 3 SAS RAID Setup After entering the SAS RAID configuration interface these information will pop out including the menu list information the information of the HDDs connected to the SAS controller HDD ID number HDD model HDD capacity
11. gt to continue the installation 12 Installation program enters selection interface of hard disks which are used to install system In Sata Storage Devices to be mounted only list the system shows the detected storage device Please according to the actual needs click the HDD which will be used to install system add this hard disk to Install Target Devices list select a piece of hard disk as the Boot Loader and then click Next to continue installation Chapter Five Install Operating System O 13 When the installation program enters partition creating interface Please Se lect A Device If partition has been created on the hard disk the created partitions will be showed And you can delete it if you do not need it Select Free Partition or other existing partition under the hard disk The system will pop up partition Add Partition D Select root partition in Mount point In Allowable Drives window select the hard disk which is to install system Input the size of partition in Size MB and click lt OK gt to finish the creating of root partition Create the boot partition in the same way boot 2 Create the swap partition Swap Select Swap in File system Type In Al lowable Drives window select the hard disk which is to install system Input the size MB of the swap partition in Size MB Set according to the size of memory If the memory is smaller than 512MB set it as twice of the memory I
12. installation is completed click Finish according to the prompt 5 Install video driver After finishing installing network card driver do not exit installation interface of driver CD but continue to install video card driver D In the Select OS column select Windows 2008 In the Select Hardware column select video card driver 3 Click lt Next gt to start the installation Enter interface Welcome to the InstallShield Wizard and click next gt to continue 5 Enter the interface of Ready to Install the Program and click Install to start installing video card driver Installation program starts and completes installation In interface of In stallShield Wizard Completed please click Finish The system pops up window to prompt that you should restart the server to make the setting take effect Take all the disks out of the drives and select lt Yes gt to restart server Chapter Five Install Operating System EE 5 4 Manually Install Red Hat Enterprise Linux 6 1 5 4 1 Preparation Prior to Installation e Installation CD of Red Hat Enterprise Linux 6 1 1 piece of DVD 5 4 2 Installation Steps 1 Power up and start the system put the installation CD into the CD drive here take using DVD installation disk as example enter BIOS settings and make server boot from CD 2 System enters interface Welcome to Red Hat Enterprise Linux 6 1 There are the following options Ins
13. menu is used to set some configuration related to USB and displays the USB devices that the system automatically detects Legacy USB Support The traditional USB devices support function setup including Enabled Dis abled and Auto three options If set it to Auto the default does not support tradi tional USB devices when USB devices are not connected e Onboard LAN Configuration Legacy OpROM Support Launch PXE OpROM Include Disable and Enable two items and the default is Disabled 3 Chipset menu e CPU Advanced Settings This menu is used for the setup of QPI related information and memory related items OPI Configuration The submenu of this submenu can set up QPI speed mode frequency and other items DIMM Information The sub items of this menu can show memory configuration information includ ing memory total capacity current memory configuration mode and so on as well as setup of memory mode and memory rate etc Chapter Three System Setup EE V Intel R I OAT This item is used to open or close Intel I O acceleration technology including Enabled and Disabled two items V VGA Priority Set priority order of integrated graphic card and external graphic card including Offboard and Onboard two items Y Memory Mode Memory mode setup including Independent Mirroring Lock Step and Sparing e PCH Display and setup of PCH related information SMBus Controller This it
14. offering Java SE Runtime Environment 6 Update 18 plug in based on Windows system and directly install browser plug in Please install browser plug in at the client end before log in to the remote desktop 2 Remote login method Input IP address of BMC in the IP address bar of client browser and then click En ter The management log in interface will appear just as is shown in the following figure Please input default Username and Password Username admin Password admin Notes default Username and Password can conduct all module configurations and settings of permission So for security reasons it is recommended changing login pass word in time when you log in 6 3 Function Menu Introduction The default displaying interface after logging in is as follows admin Refresh Prin Dashboard FRU Information Server Health Configuration Remote Control Maintenance Dashboard Dashboard gives the overall information about the status of the device and remote server Device Information Sensor Monitoring Firmware Revision 1 1 8 Firmware Build Time Jan 3 2012 12 40 49 CST Status Sensor Reading Network Information Edit S PSE SOG R MAC Address 8C 89 A5 96 96 71 PCIE_O 30 C V4 Network Mode DHCP PCE 35 C PA IPv4 Address 10 52 11 2 e 3 m V6 Network Mode DHCP NMEN ec IPv6 Address DMM 32 C LJ CPU VR 34 C A Remote Control Launch e e HWM VIT 1 069 Volts 2D E C
15. power normally and the power G5 Chapter Seven Common Problems and Trouble shooting cable is correctly connected 2 Repeatedly press the power button to start the machine pay attention not to ex erting too much force 3 Disconnect the power cable from the system and open the chassis to check 4 Check the fastness of the cable connection and accessory plugging in the chas sis 5 Remove other external components other than Inspur s 6 Pack the chassis connect the power cable correctly and start the machine 7 2 2 Monitor Has No Display The server can be powered on the host can start and run normally but the moni tor doesn t work 1 Check the correctness and fastness of the signal cable and power cable con nected to the monitor 2 Make sure to power on the display 3 Adjust the contrast and brightness of the monitor to confirm whether it can dis play or not 4 Shut down the system and disconnect the power cable to check whether there is curve in the pin at the connecting end of the monitor signal cable and the host 5 Find another monitor for test if possible 6 If the machine is installed with components other than Inspur ones please re move them first 7 With the permission of Inspur technical support personnel you may pull and plug RAM and clear CMOS for test 7 2 3 Installation System Can t Find Hard Disk 1 When installing the system directly booted with the system CD if it prompts that no h
16. prior to the starting sequence of hard disk the system will fail to be booted from hard disk The following introduces the making method for the driver of onboard hard disk controller when using Inspur driver U disk to install the operating system For driver making of external RAID card or SAS card please refer to the corresponding contents in the driver CD for external board card Make Driver 1 Prepare a set of computer installed with Windows system and connect the Inspur driver U disk to the USB interface of the computer as shown in the picture be low Inspur driver U disk will be identified as two parts simulation floppy driver 3 5 Floppy A and normal partition of U disk Removable Disk E in which the disk character E in Removable Disk E will be different according to the actual partitions of your computer l1plad te tdt wew fawxtes Tools tiep s IE O P P Sex gt Foes Gy X M9 address id Hy Computer ERE Lu Hard Disk Drives Local Duk C Local Disk Devices with Removable Storage 34 inch Floppy Disk Notes Before connecting the Inspur driver U disk to the computer if your computer is configured with standard floppy please enter BIOS and close this Chapter Five Install Operating System HE standard floppy if your computer is connected with USB floppy please first dis connect USB floppy It must guarantee that when the Inspur driver U disk is con nected to your comput
17. rail suit of 2U server includes the following objects 1 Guide rail 1 set one for left and one for right rail 2 Fixing screw 1 wrap The rail consists of inner rail outer rail and fixed frame just as shown in picture 1 inner rail outer rail front fixed frame back fixed frame Picture 1 8 3 Installation of Inner Rail Please install the inner rail to the cabinet according to the following description 1 Firstly take out the inner rail from the guide rail hold the front fixed frame of the whole guide rail and pull outward the inner rail just as shown in picture 2 ie Picture 2 2 When the inner rail can t be pulled any more stir the bayonet lock shown in picture 3 along the direction of arrow and then pull outward the inner rail completely with even strength Picture 3 3 Fix the inner rail on the four screws on the cabinet the fix position shown in picture 4 Chapter Eight Server Installation Guide EE 8 Picture 4 4 Make the smooth side of the inner rail confront the side of cabinet get the holes on the inner rail and screws on cabinet corresponding with each other well let the inner rail cling to the cabinet closely then push the inner rail in the direction rear of the ma chine of red arrows shown in picture 5 and clamp tightly the inner rail with double screw bolts A Special notice when push the inner rail in the direction of red arrows if the inner rail can t be clamped into
18. the USB devices Front USB interface For connecting the USB devices Hard disk bay For installing 1 8 pieces of hard disks Hard disk bay For installing 9 16 pieces of hard disks Hard disk bay For installing 17 24 pieces of hard disks Optional Slim CD drive no Slim CD drive CD drive slot for configuration of 17 24 pieces of hard disks 2 3 4 5 6 7 Power light is always green when server 8 9 1 Powe door net runs power light is off when server stops Power button Server on off button ID light button To turn on the ID light 0 Network card 2nd and En n connected or data is Ath indicator light 818 Off network is not connected Chapter Two Product Introduction It warns fan failure This light is always off when the system is in normal status Fan failure indicator The light is always amber in case of sys light tem fan failure The light is also amber when server is turned off AC power is connected and BMC is initialized It warns the abnormal status of the system such as over high temperature amber Abnormal system in This light is always off when the system dicator light works normally But the light is also on when the server is connected with AC and BMC is initialized Blinking network is connected or data is transmitting green Off network is not connected Network card 1st and 3rd indicator light ID light User machine locating light blue Front VGA interface
19. the cover of the host or to dismount and replace any component in the system by yourself unless otherwise informed by Inspur only maintenance technicians trained by Inspur have the right to disassemble the cover of the host dismount and replace the internal components Warning 2 Please connect the equipment to appropriate power supply and the power should be supplied by external power supply which is indicated on the rated input label To prevent your equipment from damages caused by momentary spike or plunge of the voltage please use relevant voltage stabilizing equipment or uninterruptible power supply equipment Warning 3 If extended cables are needed please use the three core cables matched with correct earthed plug and check the ratings of the extended cables to make sure that the sum of rated current of all products inserted into the extended cables do not exceed 80 of the limits of the rated currents of the extended cables Warning 4 Please be sure to use the supplied power supply component such as power lines power socket if supplied with the equipment etc For the safety of equipment and the user do not replace randomly power cables or plugs Warning 5 To prevent electric shock dangers caused by leakage in the sys tem please make sure that the power cables of the system and peripheral equip ment are correctly connected to the earthed power socket Please connect the three core power line plug to the three core AC power soc
20. value For selecting the next menu or value For selecting the left menu or value For selecting the right menu or value For returning to the superior menu or the main menu For changing the item value for changing the current menu item into the next item value The key only displays the item values relevant to the item itself rather than all the item values For changing the item value for changing the current menu item into the previous item value The key only displays the item values relevant to the item itself rather than all the item values The help key for displaying the relevant explanation of current menu Chapter Three System Setup O For restoring to the default setting of the system safety perfor mance Load Previous Values For restoring to the default setting of the system best performance lt F10 gt For saving the CMOS s setting and exiting Enter For operating current order or entering submenu 1 Main menu The Main menu appears first when entering the BIOS setup system The BIOS version information and memory capacity can be examined here And the system date and time can be set e BIOS Information Show the BIOS version and BIOS modification time e Memory Information Show the system memory capacity e System Date Set the system date in format of week month day year e System Time Set the system time adopting 24 hour system in format of hour minute second 2 Adva
21. Common Problems and Trouble shooting machine The system will produce minidump file automatically in the next blue screen 7 3 Machine Alarm If there s machine alarm in startup or utilization process please refer to the fol lowing measures 1 If this happens after you plugged in some external board you may need to pull off this device and to do another test If the alarm goes off it shows that your external board is incompatible with the machine It is suggested not to use it any more if the alarm is still on please go on referring to the following steps 2 Locate the alarm sound e When the alarm sound is from the front of the chassis usually we notice abnor mal changes of the fault indicating light There is the possibility of abnormal fans or hard disk module e If the alarm sound is from the rear of the chassis please check whether a redun dant power supply is configured or not and whether there is an abnormal status light of the power supply module or a module without power cable when power alarm goes on the shield switch can be pressed to stop it e If the alarm sound is in the chassis the alarm may be from motherboard RAID card or hard disk back plane If it is also accompanied by no display on the monitor or power on faults there is high possibility of something wrong with motherboard You can try to pull or plug RAM or clear CMOS If the starting self check is normal and the alarm starts when the RAID card is under test
22. Con sidering the safe and green recycle utilization and humankind benefit the user should refer to retailers or local government departments for the related disposal method and locations 9 The copyright of the marks and names of all the software and hardware prod ucts involved in this manual is reserved by the relevant companies 10 In the statements above us indicates Inspur Group Co Ltd Inspur Group Co Ltd holds the right of final explanation about the above statements Regard This Manual e Chapter One Safety Information In this chapter safety information regarding server usage is introduced e Chapter Two Product Introduction In this chapter the technical characteristics appearance features I O interface technical specification of this server are introduced e Chapter Three System Setup In this chapter the setup of the main board BIOS of this server is introduced e Chapter Four SAS RAID Setup In this chapter how to setup SAS RAID of onboard SAS controller is introduced e Chapter Five Install Operating System In this chapter how to install the main operating system to this server is intro duced e Chapter Six Instructions for Motherboard Management Controller In this chapter how to use onboard management function is introduced e Chapter Seven Common Problems and Trouble shooting In this chapter solutions to some common problems are introduced e Chapter Eight Sever Installation Guide In this
23. D Insert the Inspur driver CD into CD drive click the blue dolphin icon under the installation or running program item in the auto play interface after the running of CD and then input the navigation code on the driver CD set in the navigation code veri fying interface popped up click lt OK gt and it will enter the installation interface auto matically In column Select OS select Windows 2003 3 In column Select Hardware select Network card driver Click lt Next gt to start the installation Enter the interface of Intel R Network Connections and click Install driv er and software Enter the interface of Welcome to use click lt Next gt to continue Enter the interface of License Agreement select I accept the terms in the license agreement and click lt Next gt to continue Enter the interface of Setup Options and click lt Next gt to continue Chapter Five Install Operating System O 9 Enter the interface of Ready to Install the Program and click lt Install gt to continue The program starts to install click Finish according to the prompt 4 Install graphic card driver After the installation of network card driver stay in the installation interface of driver CD and continue with the installation of graphic card driver D In column Select OS select Windows 2003 2 In column Select Hardware select graphic card driver Click lt Next gt
24. Dear User of Inspur Yingxin Server Heartfelt thank you for your use of Inspur Yingxin Server This manual introduces the technical characteristics the system instal lation and setup of the server to help you to fully understand and expediently use this server Please deliver the package of our product to the waste recycling station for recycling in favor of pollution prevention and humankind s benefit This manual is the property of the Inspur Group Co Ltd This User Manual is not to be copied by any group or person in any manner without the consent of Inspur Group Co Ltd The Inspur Group Co Ltd reserves the right of revising this manual momentarily Any alteration about the content of this manual will not be informed Please contact Inspur Group Co Ltd if you have any questions or ad vice about this manual Inspur Group Co Ltd March 2012 nspur is registered trademark of the Inspur Group Co Ltd Other trademarks belong to other corresponding registered companies Statements Please read the following statements before you use this server Only when you have read this statement hereinafter and agreed the following terms you can formally use this server If you have any questions about the following terms please contact our supplier or us directly If you have no questions about these terms and start to use this server it acquiesces that you have agreed the following terms 1 We must call your attention t
25. For connecting display devices Q Hard disk tray indicator light Hard disk working status indictor light Hard disk failure alarm indictor light Hard disk working status The light is always green when hard disk is read indictor light ing and writing The light is always red in case of hard disk failure The light is always blue when hard disk is being located The light is always purple when RAID card is re building Hard disk failure alarm indictor light Chapter Two Product Introduction EN 2 3 Back Panel View ge CJ E 0 Se 0000 Back Panel View l For connecting power line 2 For inserting the external PCI E expansion card 3 For connecting serial interface devices 4 VGA interface For connecting display devices 10 Gigabit network inter Lou 5 Optional 10 Gigabit network fics Ostional ptiona igabit networ For th f IPMI 6 TE E or the usage of onboard manage ment function 7 Network card 1 interface Integrated Gigabit network card 1 interface 8 9 10 11 ti int t i it network Network card 3 interface Op ional integrated Gigabit ne won card 3 12 Optional interface need to configure special mother P board Network card d interface Optional integrated Gigabit network card 4 13 Optional interface need to configure special mother P board Chapter Three System Setup HE Chapter Three System Setup In this chapter the wire jumper of motherboard an
26. Install Red Hat Enterprise Linux 6 1 s es 41 Chapter Six Instructions for Motherboard Management Controller 45 6 1 Management Chip BMC IP ciet eerte t e E EE ak 45 O2 Remote bruit 45 6 3 Function Menu Introduction ssseeeeeeeeeeeee nne ee ene ener 46 Chapter Seven Common Problems and Trouble shooting 55 Tol Restarting SerVeL ao eee mre peo ere HE ERE Ho de iet EI rr EY 55 7 2 Problems When Starting the Machine ssseeeeee 55 To Machme Alaris eare a i e ES S Ea 58 7 4 Additional NOt65 iir etd emt et e nrbt ios ine oe ey aree 58 7 5 Technical Support Information ssssseeeeeeeeen 59 Chapter Eight Server Installation Guide erect eene eene 60 8 Cabinet Pr patatioti iie ere eem E SEGUE san 60 8 2 Components Needed in Server Installation ssssssss 61 8 3 Installation of Inner Rail sese 61 8 4 Install Guide Rail into Cabinet essen 62 8 5 Install the Server to Cabinet eese eene 63 Chapter One Safety Information HE Chapter One Safety Information Ahh the following warnings show that there are potential dangers that may cause property loss personal injury or death Warning 1 The power supply equipment in the system may generate high voltage and dangerous electrical energy and thus cause personal injury Please do not dismount
27. Perform Action to execute After that ID light of front and back panel of corresponding server will be off GD Chapter Six Instructions for Motherboard Management Controller EE 6 Maintenance menu Dashboard FRU Information Server Health Firmware Update Firmware Update Restore Factory Defaults Upgrade firmware of the device Press Enter Update Mode to put the device in update mode System Administrator WARNING Please note that after entering update mode widgets other web pages and services will not work All open widgets will be closed automatically If upgrade process is cancelled in the middle of the wizard the device will reset s admin ad strator Refresh V Print Logout Configuration Remote Control Maintenance HELP Enter Update Mode This function menu can realize remote update of BMC firmware and restart of IPMI card QD Firmware Update menu This menu can realize update of IPMI management card Firmware We recom mend users not updating it by themselves If it really needs to be updated the update file must have been approved by us 2 Restore Factory Default This menu is used to load factory default of IPMI management card 8 System Administrator This menu is used to change system administrator s rights and password Chapter Seven Common Problems and Trouble shooting Chapter Seven Common Problems and Trouble shooting This chapter focuses on the common problems and
28. Trouble shooting of the server If you are not sure about the cause of a failure and its removal method please contact our customer service center for solution Notes When replacing or installing hardware device for the server you should disconnect the power cable from the server completely It is recommended to use the anti static wrist strap and to earth connect the other end to provide electrostatic protec tion in dismounting the server 7 1 Restarting Server When a failure occurs please try to restart the machine according to the following methods first Purpose How to operate Restart the software clear up system memory and restart lt Ctrl AlttDel gt the operating system Clear up system memory self check the POST again and Reset button restart the operating system Cold boot again switch off and restart the system power so that to clear up the system memory to self check the POST again to restart the operating system and to power up all peripherals again 7 2 Problems When Starting the Machine Some problems often occur when the machine is started generally due to incor Power button rect hardware installation and configuration You may find and solve the problems by the following methods 7 2 1 System Can Not Be Powered on After pressing the power button the power light is not on and the system stays in non electric state Please try the following steps 1 Check whether your power socket can supply
29. a character size within 4 32 and a password of at least 8 character size 5 Remote Control Menu Refresh Pri Dashboard FRU Information Server Health Configuration Remote Control Maintenance Console Redirection Console Redirection Server Power Control m Press the button to launch the redirecton console and manage the server rem TL ea TIT This section allows you to perform various remote operations on the server in cluding operating remote console system switch and other control operations D Console Redirection menu log in console After choosing this menu the system will log in remote desktop Click Launch behind Remote Control to log in console When using if prompted to install Jviewer browser please install according to the prompt A Remote desktop Video menu Pause Redirection Resume Redirection Compression Mode Compression mode setting Dect Quantization Table Remote desktop display qualification setting Full Screen Full screen display of remote desktop Exit Exit remote desktop B Remote desktop Keyboard menu Chapter Six Instructions for Motherboard Management Controller Video Keyboard Mouse Options Media Keyboard Layout VideoRecord Help Zoom Size 100 T Hold Right Ctri Key o a Hold Right Alt Key e J Hold Left Ctrl Key Gg Hold Left Alt Key Left Windows Key Right Windows Key gt Ctri Alt Del Context Menu Menu Function
30. aft of the mouse 4 It is suggested that you use the keyboard and mouse tested for compatibility by Inspur group or replace with other keyboard and mouse for testing 7 2 6 System Blue Screen Halt or Restart For blue screen restart or halt of the machine in the utilization of the system you may refer to the following measures 1 If other external non Inspur components or some application program soft wares are installed before the fault it is suggested removing it and going on to test your server 2 Use the latest antivirus software for antivirus test 3 It is suggested that you record the displayed information code for blue screen such as stop c000000218 stop 0x0000007b This kind of information reveals prob lems in the system It is suggested that you reinstall it For the installation process you can refer to the user manual 4 If all above operations failed to solve the problem it is suggested that you backup the file winnt minidump in disk C and call the service center for support from professional technical engineers who may ask you to provide minidump file for further analysis on the cause for blue screen and halt If there is no minidump folder in disk C please refer to the following steps right click on My Computer select XProperty2 advanced startup and recovery then select settings change write debugging information in the next page to small RAM dump and restart the GD Chapter Seven
31. and displays the installation prog ress after the completion click lt Next gt to continue the installation 9 Complete the installation click Finish according to the prompts take out Inspur driver CD and restart the system Chapter Five Install Operating System EE Sa 4 Install network card driver D Insert Inspur driver CD into CD drive click the blue dolphin icon under the in stallation or operation procedure item in the automatically playing interface popped out after the disk s running input the navigation code on the driver CD case in the naviga tion code verification interface popped out after the operation of CD and click lt OK gt to enter the installation interface automatically In the Select OS column select Windows 2008 In the Select Hardware column select Network card driver Click lt Next gt to start the installation OROROORO Enter the interface of Intel R Network Connections and then click Install driver and software option Enter interface of welcome to use and click lt next gt to continue QG Enter the interface of License Agreement select I accept the terms in the license agreement and then click lt Next gt to continue Enter the interface of Setup Options and click lt Next gt to continue Enter the interface of Ready to Install the Program and click lt Install gt to continue The installation program starts to install when the
32. and whether the HDD is part of the volume etc the existing RAID volume information including volume ID number name RAID level capacity state and whether can boot information as show in the below figure Chapter Four SAS RAID Setup Intel R Rapid Storage Technology enterprise SCU Option ROM 3 8 1 137 78 Copyright C 2883 11 Intel Corporation All Rights Reserved E 1 1 Create RAID Volume 3 Reset Disks to Non RAID 2 Delete RAID Volume 4 Exit C 1 Physical Devices ID Device Model Size Type Status Vol ID ST 11 Z1 1 8TB BBNME It11 Select LIESCI Exit CENTER Select Menu The executable menus of the configuration interface of SAS RAID are the follow ing four e Create RAID Volume e Delete RAID Volume e Reset Disks to Non RAID e Exit Exit the configuration interface of SATA HostRAID I Create RAID Volume menu After entering the configuration interface of SAS RAID it can select the menu with up and down arrow keys and then press Enter key to create RAID volume menu or input the number key before menu to create RAID volume menu The system will display the following menu options Name Please input the volume name of less than 16 characters without special characters RAID Level Please select RAID volume level If it has not created volume at present there are four volumes for selection such as RAIDO Stripe RAID 1 Mirror RAID10 RAIDO 1 and RAIDS5 Parity and please select the levels
33. ard disk can be found please check the normality of the disk state and power on self check hard disk state 2 If the power on self check can detect the hard disk but the hard disk can t be detected when installing the system it may be caused by the following conditions e If you are using the system CD to boot and install the operating system directly the hard disk drive is generally added through the floppy driver or Inspur driver U disk When using USB floppy driver to add the drive please set the BIOS first and close the onboard floppy driver controller When using Inspur driver U disk to add the drive Chapter Seven Common Problems and Trouble shooting please connect Inspur driver U disk when starting the server e Please check whether the driver having been made is correct or not the drive for external RAID card should be made directly from the attached RAID card driver CD and whether there is fault in the floppy disk or Inspur driver U disk 7 2 4 Instruction of Onboard SATA Controller If it is configured onboard SATA HostRaid it only supports windows system of above Windows XP versions and connects 6 SATA devices at most 7 2 5 Keyboard and Mouse Do Not Work 1 Check whether the cable joint of the mouse and keyboard is plugged and con nected correctly Make sure the joint pin has no curve 2 Check whether the mouse setting in the control panel of the operating system is correct or not 3 Clean the scrolling and drive sh
34. chapter how to install server to the cabinet by rail is introduced We suggest you read this manual seriously before you use this server for fear of the unnecessary faults in your operation Address Inspur Group Co Ltd NO 1036 Langchao Road Jinan China Post Code 250101 Content Chapter One Safety Information 4 eese esee eese eee ee neta neta stant ta sena tnato 1 Chapter Two Product Introduction eee eee eee eee eene eene tete ttn tnats 6 2 1 Server Technical Specification senem 6 2 2 Front Panel View s oie eret eor ird eate OP Fes Fred Hed Ce e daga PEE 8 23 Back Panel VIEW ahud IHRER IRE RIDERE ER iain 10 Chapter Three System Setup 4 cerei eee eese eee ee neta stent tta sesta sena stnao 11 3 1 System BIOS Seprene ini ridosi eri orir oNN 11 3 2 Motherboard Jumper Settings sse 19 Chapter Four SAS RAID Setup sese 21 4 1 How to Enter the Configuration Interface of SAS sss 21 4 2 Control Key Application 5 eer inian ia ence 21 d sS RAID SEQUAMUR E te TE 21 Chapter Five Install Operating System eese esses nein eene tne tn tnnt tnano 25 5 1 Application Instructions for Inspur Driver U Disk ssessss 25 5 2 Manually Install Windows Server 2003 sssssssseee 30 5 3 Manually Install Windows Server 2008 sse 36 5 4 Manually
35. conduct off the static electricity on the body by contacting the metal earthing objects such as the unpainted metal surface on the chassis to prevent the static electricity on the body from conduct ing itself to the sensitive components For electrostatic sensitive components not ready to be installed for application please do not take them out from the antistatic package materials During the work please touch the earthing conductor or the unpainted metal sur face on the cabinet regularly to conduct off the static electricity on the body that may damage the internal components 7 When dismounting the internal components with the approval of Inspur please pay attention to the following matters Switch off the system power supply and disconnect the cables including discon necting any connection of the system When disconnecting the cables please grab the connector of cables and plug it out and never pull the cables Before dismounting the cover of cabinet or touching the internal components the products need to be cooled down Before dismounting and touching any electronic component in the equipment you shall conduct off the static electricity on the body by touching the metal earthing objectives During the dismounting process the operation shall not be too big so as to pre vent damage to the components or scratching of the arms Carefully deal with the components and plug in cards and please never touch the compon
36. copy files 19 Enter interface Congratulations you Red Hat Enterprise Linux installation is complete It indicates that the system is successfully installed Click Reboot and take out the installation CD The system reboots automatically 20 The system reboots to enter interface Welcome Please click Forward to continue the installation 21 The installation program enters interface License Agreement Select Yes I agree to the License Agreement and click Forward to continue the installation 22 The installation program enters interface Set Up Software Updates Click Forward to continue the installation 23 The installation program enters interface Create User According to actual needs set user name and password to add user and click Forward to continue the in stallation 24 The installation program enters interface Date and time Please set the cor rect time and date Then click Forward to continue the installation 25 The installation program enters Kdump setting interface Set according to the actual need and select Forward to continue the installation 26 Input Username and Password to log in the system Chapter Six Instructions for Motherboard Management Controller SGH Chapter Six Instructions for Motherboard Management Controller This product integrates IPMI management card by which the user can remote log in the server The following will describe the applica
37. d BIOS function setup of this server are introduced Only operator or administrator with qualification of system main tenance can implement these operations described in this part 3 1 System BIOS Setup BIOS is the basic input and output system With some special setting programs it can adjust the system parameter and the hardware parameter BIOS has great influence on the starting and running of the system so that setting parameters improperly may arise the conflict among hardware resources or affect the system s performance Hence understanding the BIOS setup is significant to the configuration of your server If there is no especial requirement we suggest you using the default value and not altering the parameters at will Notes 1 Before the server BIOS setup is altered please record the corresponding origi nal setup Hence when there are operating problems in the system due to the alteration the setup can be restored 2 The factory default system value is usually the optimized setup Don t try to al ter the parameters before you understand their denotations 3 The common setup is introduced in detail in this chapter The less referred op tions in the application procedure are explained simply or not mentioned 4 The contents of the BIOS may be differing based on the different configurations of the products hence the detailed introduction is elided 3 1 1 How to Enter BIOS Setup Power up and start the server then the system
38. ds that may include the batteries and other components with other wastes For relevant battery recovery please contact the local waste recovery and treatment mechanism If what you bought is the chassis besides carefully read the installation de scription attached with the cabinet products and get known about the special warning notices and installation process you must abide by the following preven tive measures to guarantee the cabinet to be stable and safe Warning 10 Before installing equipment in the chassis please install front and side supporting feet on the independent chassis for cabinet connecting with other chassis it shall install the front supporting foot first If you fail to install cor respondingly the supporting foot before installing equipment in the chassis it may cause the cabinet to turn over in some cases and thus may cause personal injury Therefore it is necessary to install supporting feet before installing equipment in the chassis After installing the equipment and other components in the chassis it can only pull out one component from the cabinet through its sliding component at one time Pulling out several components at the same time may lead the cabinet to turn over and cause serious personal injury Warning 11 Please do not move the chassis Considering the height and weight of the chassis at least two people are needed to complete its movement Warning 12 Declaration C25 Chapter One Safety Informat
39. e Adjust the four support feet at the bottom of the adjustment cabinet to make the cabinet stable on the ground Meanwhile dismount the cabinet door for convenience of guide rail installation Cabinet grounding to avoid electric shock a grounding device must be installed in the cabinet If the server power line is installed in the power socket which consti tutes a portion of the cabinet grounding should be properly provided for the cabinet If the server power line is inserted into the power socket in the wall the grounding device in the power socket just provides grounding for the server and then proper grounding protection for cabinet and other internal devices should be provided We recommend you to use the cabinet specially designed by Inspur for the server If so the internal of the cabinet should be already grounded Please don t change the ground joint in the cabinet unless it is of absolute necessity Temperature if installed in the cabinet the operation and working temperature of the server can t be lower than 5 C and higher than 35 C Ventilation the cabinet used by server cluster must provide enough wind cur rent for the front of the server to ventilate and must ensure 4100Btu heat discharge per hour The cabinet selected by the cluster and ventilation condition must correspond with requirements of the server Chapter Eight Server Installation Guide O 8 2 Components Needed in Server Installation Accompanying guide
40. e configuration interface of SAS RAID it can select the menu by the up and down arrows and then press Enter key to enter the menu System warning Are you sure you want to exit Y N Enter Y and then it will exit the configuration interface of SAS RAID while enter N it will cancel the operation and exit Chapter Five Install Operating System HE Chapter Five Install Operating System This chapter primarily focuses on the method for manually installing the major operating system on the server For operating steps of Ruijie intelligent installation op erating system refer to corresponding chapters and sections of Ruijie Server Kit User Manual During manual setup of the operating system some operating system may need the floppy drive or Inspur driver U disk to load the driver of hard disk controller Re fer to the readme pdf file under the root directory in Inspur driver CD for the making method of the driver floppy disk If the system you purchased is configured with Inspur driver U disk you may refer to relevant contents of this chapter for the making method of Inspur driver U disk After logging the driver CD making interface you can check and make the con troller driver needed to load in the process of operating system installation under re lated configuration If your server is configured with external RAID card please refer to the User Manual in the attached CD of external RAID card to add hard disk contro
41. em is used to open or close system bus controller including Enabled and Disabled two items Restore AC Power Loss Set power supply status after system powers off Power off is shutdown status which needs to start up manually Power on is the automatic startup status Onboard SATA RAID Oprom This item is used to open or close integrated SATA RAID controller rom includ ing Enabled and Disabled two items e ME Subsystem This menu is used to show ME subsystem related information including BIOS in terface version information version FW status FW alarm code and other information 4 Server Mgmt menu e Wait For BMC This item is used to setup whether waiting for BMC startup or not including En abled and Disabled two items e System Event Log This menu shows the features of system event log e View System Information Enter this menu to check system related information including product name product manufacturer product version product serial number SDR version informa tion BMC version information and others e BMC network configuration Chapter Three System Setup m This menu is used to setup the configuration information of BMC network inter face Lan channel 1 Related items of this menu can be used to setup the access method to network card IP address IP address subnet mask and router IP address and other information Lan channel 2 Related items of this menu can be used to setup the acce
42. ents or connection points on the plug in cards When taking the plug in cards or components you should grab the edges of the plug in cards or components or lt gt their metal fixed supports Chapter One Safety Information 8 During the process of cabinet installation and application please pay attention to the following matters After the installation of cabinet is finished please ensure that the supporting feet have been fixed to the rack and supported to the ground and all weight of the rack have been fell onto the ground It shall install into the cabinet according to the sequences from the bottom to the top and first install the heaviest component When pulling out the components from the cabinet it shall apply force slightly to ensure the cabinet to keep balance and stabilization When pressing down the release latch of the sliding rail of components and slid ing in or out please be careful as the sliding rail may hurt your figures Never make the AC power branch circuit in the cabinet overload The sum of cabinet load shall not exceed 80 of the ratings of branch circuits Ensure that components in the cabinet have good ventilation When repairing components in the cabinet never step on any other components Chapter Two Product Introduction Chapter Two Product Introduction 2 1 Server Technical Specification Processor Two way Intel Xeon E5 26XX series CPU Up to two pieces 130w Interface Tw
43. er the analog floppy disk under Windows system shall be identified to be A and only by this can the normal making of subsequent driver be guaranteed 2 Put the driver CD Inspur driver CD and RAID card driver CD into the CD ROM and the driver making software will operate automatically If the system forbids the automatic operation of CD please enter CD directory and operate documents of dolphin bat Inspur driver CD in CD or setup exe RAID card driver CD in CD direc tory 3 Methods for making drivers by using Inspur driver CD 1 After operating dolphin bat documents the system will enter the interface of Input navigation No please Welcome to use Inspur driver CD Les fe Input navigation No please Tip navigation No on CD box OK Cancel Input the navigation code in the text box the navigation code is shown in CD box click OK button and it can log in the main interface of driver making software Click Cancel button and exit the logging 2 Having input the navigation code and logged in the system enter the main interface of driver making software and the main interface is shown in the following picture Chapter Five Install Operating System SS Es Welcome to use Ins Select Hardware intel sata hostraid 32bit v k Wm 3 Click the Make Drive button and enter the driver making interface as shown in the following picture la Welcome to u
44. es if you use Inspur driver U disk to load controller drive please refer to the attached Inspur Driver U disk Instructions for guide e Please connect well the USB floppy drive or Inspur driver U disk before the system starts up 5 2 2 Installation steps 1 Power up to start the server and put the installation CD of Windows Server 2003 into CD drive and then enter the BIOS to configure so that the server can be boot ed from CD 2 Press any key when the system presents Press any key to boot from CD and the system will start Windows installation program from CD 3 When the screen presents Press F6 if you need to install a third party SCSI or RAID driver please press F6 key Notes when installing EMT64bit version system if it prompts the server type purchased you can select configuration according to the detailed configuration of purchased server When the system displays Setup could not determine the type of one or more mass storage press S key When the system prompts to insert a floppy disk after selecting LSI MegaRAID SAS RAID Controller Driver Server 2003 32 bit in the drive list press Enter to load driver If Inspur driver U disk is used please connect Inspur driver U disk well be fore the system starts up Firstly ensure that the corresponding driver has been made into the 3 5 Floppy disk A partition of the Inspur driver U disk Select LSI MegaRAID SAS RAID Controller Driver Serve
45. evices such as Storage Area Networks SANs This option will allow you to add FCoE Iscsi Zfcp disks and to filter out devices the installer should ignore Here we choose Basic Storage Devices and then select Next to continue instal lation 8 System enters Please name this computer The hostname identifies the com puter on a network Please input Hostname Here be able to select Configure Network for network configuration at the win dow lower left corner Be able to add or delete network card and configure network IP address After the completion of the network configuration select Next to continue installation 9 Enter time zone selection interface Please select the nearest city in your time zone select Asia shangha and then click Next to continue installation 10 Enter the interface of Root Password settings According to your need set the Password with at least six characters and then click Next to continue installation The root account is used for administering the system Enter a password for the root user 11 Enter selection interface of installation modes Which type of installation would you like There are the following several installation options Use All Space Replace Existing Linux System s Shrink Current System Use Free Space Create Custom Layout Here this installation shall take the customizing manual partitioning as an exam ple please select Create Custom layout and click lt Next
46. f the memory exceeds 512MB you can set the swap partition as 2GB and click lt OK gt to finish the creating of swap partition You can also create other partitions as needed click lt Next gt to continue the instal lation after the creation 14 The system pops up window Writing storage configuration to disk The partitioning options you have selected will now be written to disk Any data on deleted or reformatted partitions will be lost Select Write changes to disk to continue installation The system begins to for mat hard disk partition 15 The installation program enters Boot Loader setting interface Set as needed and click lt Next gt to continue installation 16 The system prompts The default installation of Red Hat Enterprise Linux is a basic server install You can optionally select different set of software now Please according to actual needs select to install the type and software package that needs to be customized Here select Customize now and click Next to continue installation 17 The installation program enters program package selection interface Please according to actual needs confirm to select the software packages to be installed Click Next to continue the installation Here we select two software packages X Windows System in Desktops and Development Tools in Development Chapter Five Install Operating System EN 18 Installation program begins to build file system and
47. g the installation of Windows operating system if the driver of hard disk controller is loaded by using Inspur driver U disk entering the interface of disk parti tion the Inspur driver U disk will occupy a disk letter If the disk is not divided U disk will occupy disk C and if the disk has other partitions U disk will occupy other disk letter please distinguish according to the actual hard disk partition If there are other partitions on the disk at this moment it needs to delete all of them and then create new partitions on the hard disk and the U disk will not occupy disk letter any more If the disk is not divided it needs to create one disk partition on the unallocated space and then delete this newly created disk partition And at this time the U disk will not occupy any disk letter any more Then create disk partition based on actual need and complete the installation of operating system according to the instructions Notes Be sure to distinguish U disk from hard disk and never delete or for Chapter Five Install Operating System EN o mat U disk 5 2 Manually Install Windows Server 2003 5 2 1 Preparation Prior to Installation eInstallation CD for Windows Server 2003 Enterprise SP2 here take 32 bit oper ating system installation as an example eInspur driver CD eRAID card drive floppy disk made by Inspur RAID card driver CD for details please refer to the electric version of RAID card driver CD user manual Not
48. hapter Six Instructions for Motherboard Management Controller XEM The following function menus can be found on the top of the interface Dash board FRU Information Server Health Configuration Remote Control and Mainte nance 1 Dashboard menu In this menu the information of management chip Firmware version modification time and MAC address etc can be viewed Click Edit button behind Network Information to enter network settings inter face And set IP address and gateway as well as other information Click Launch behind Remote Control to log in console When using if prompt ed to install Jviewer browser please install according to the prompt 2 FRU Information menu This menu displays FRU Information including Basic Information and Server Information two parts Basic Information shows ID and names of FRU device Server Information displays server whole machine s type name manufacturer and other Infor mation Detailed information is below s admin Administrato Refresh Print Logout Dashboard FRU Information Server Health Configuration Remote Control Maintenance HELP Field Replaceable Unit FRU This page gives detailed information for the various FRU devices present in this system Basic Information FRU Device ID 0 FRU Device Name BMC FRU Server Information m Chassis Type Rack Mount Chassis Product Name NF5280M3 Product Manufacturer Name Inspur Product Part Number 00001 Pr
49. hat you must not alter any other parameters in the motherboard BIOS of this server at any time except for the parameters which we pro mote that you can alter 2 If there are any hardware problems when you use this server or you wish to up grade the hardware please feed back the detailed hardware configuration of your server to our Customer Service Don t disassemble the server case or any hardware compo nents in the case by yourself 3 In this server the MEMORY CPU CPU Fan Fan Hard Disk Bracket Hard Disk and so on are all in given standard Please don t use them together with the corre sponding components of any other computers 4 When you have any software problems during the application of this server we hope that you firstly contact the corresponding software supplier and then he will contact us in favor of communication so as to solve your problem together especially for the software problems about the installation and operation of the database network management software or other networking products 5 Please read carefully our user manual before you use Inspur Yingxin server 6 We must call your attention that in the application process you should pay at tention to doing necessary backup of your file 7 This is a Grade A product and this product may cause radio jamming In this case users need to adopt feasible measures to the interference 8 When the product is out of use please do not dispose it with other wastes
50. hem in places not to be stepped on or knocked down and ensure not to place other objectives on the cables 4 Before dismounting the cover of host or contacting the internal components you shall cool down the equipment first to avoid damaging the main board please power off the system and wait for 5 seconds and then dismount the components from the main board or disconnect the connection of peripheral equipment of the system 5 If there are modulator demodulator telecommunication or local area network options in the equipment please pay attention to the following matters In case of thunder and lightning weather please do not connect or use the modu lator demodulator Otherwise it may be subject to lightning strike C35 Chapter One Safety Information Never connect or use modulator demodulator in moist environment Never insert the modulator demodulator or telephone cables to the socket of net work interface controller NIC Before unpacking the product package contacting or installing internal compo nents or contacting un insulated cables or jacks of the modulator demodulator please disconnect the modulator demodulator cables 6 In order to prevent the electrostatic discharge from damaging the electronic components in the equipment please pay attention to the following matters You shall conduct off the static electricity on the body before dismounting or contacting any electronic component in the equipment You can
51. ion HUE The product is Grade A product and in the living environment it may cause radio interference In such case it may need the user to take feasible measures for the inter ference Notes in order to help you use the equipment the following considerations can help avoid the occurrence of problems that may damage the components or cause data loss 1 In case of the following cases please unplug the power line plug of products from the power socket and contact the customer service department of Inspur The power cables extended cables or power plugs are damaged The products get wet by water The products have fallen off or been damaged Objects fall into the products When operating according to the operation instructions the products cannot function normally 2 If the system becomes damp please treat it according to the following steps Switch off the power supplies of the system and the equipment disconnect them with the power socket wait for 10 to 20 minutes and then open the cover of the host Move the equipment to the ventilation place to dry the system at least for 24 hours and make sure that the system is fully dried Close the cover of the host re connect the system to the power socket and then start the equipment In case of operation failure or abnormal situation please contact Inspur and get technical support 3 Pay attention to the position of the system cables and power cables wire t
52. ket that is well earthed and easy to access be sure to use the earthing pin of power lines and do not use the patch plug or the earthing pin unplugged with cables In case of the earthing conductors not installed and it is uncertain whether there are appropriate earth ing protections please do not operate or use the equipment Contact and consult C with the electrician please Chapter One Safety Information Warning 6 To avoid short circuit of internal components and fire or electric shock hazards please do not fill any object into the open pores of the system Warning 7 Please place the system far away from the cooling plate and at the place with heat sources and be sure not to block the air vents Warning 8 Be sure not to scatter food or liquid in the system or on other components and do not use the product in humid and dusty environment Warning 9 The replacement of batteries with those of another model may cause explosion When replacement of batteries is required please consult first the manufacturer and choose batteries of the same or a similar model recommended by the manufacturer Do not dismount extrude and pink the batteries or make the external connection point short circuit and do not expose them in the environ ment over 60 C Never throw them into fire or water Please do not try to open or repair the batteries and be sure to reasonably deal with the flat batteries and do not put the flat batteries the circuit boar
53. ller driver As for the graphic card and system patch program you still can refer to this chapter for installation It is suggested that you confirm in advance that the purchased machine configura tion supports the version of the installed operating system 5 1 Application Instructions for Inspur Driver U Disk Under Windows system and Linux system Inspur driver U disk can be identified as two parts simulation floppy driver 3 5 floppy disk A and normal partition of U disk UDISK PRO When you install some operating systems manually you can use Inspur driver U disk to load the drive of hard disk controller at present the operating systems that use Inspur driver U disk to load support of the hard disk controller are Windows XP or above versions Red Hat Linux 4 5 or above versions and Suse Linux 9 0 SP2 or above versions systems Warning During the installation of the operating system by using Inspur driver it may detect Inspur driver U disk on the disk partition interface at this moment the QD Chapter Five Install Operating System user must distinguish U disk from hard disk and never delete or format U disk During the installation of the operating system if it needs to boot the system from hard disk after reboot it must enter the server BIOS for setting to ensure the starting sequence of hard disk is prior to the starting sequence of U disk and the system can be booted from the disk If the starting sequence of U disk is
54. n this menu can be used to save or discard the settings of the changes in the BIOS and exit the setting program e Save Changes and Exit Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be saved and the system will exit the BIOS setup The menu function can use F10 shortcut key to realize e Discard Changes and Exit Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be discarded and the system will exit the BIOS setup e Save Changes and Reset Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be saved and the system will exit the BIOS setup and then reboot the computer e Discard Changes and Reset Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be discarded and the system will exit the BIOS setup and then reboot the computer e Saving Changes Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be saved and the system will not exit the BIOS setup e Discard Changes Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be discarded and the system will not exit the BIOS setup e Restore Defaults Select this item and press Enter After you selec
55. nced menu Advanced menu mainly includes the following submenus or configuration items ACPI Settings CPU Configuration Intel R VT for Directed I O Configuration SATA Configuration USB Configuration Serial Port Configuration PCI Subsystem Settings Runtime Error Logging WHEA Configuration Onboard LAN Configuration Serial Port Console Redirection Chapter Three System Setup The following will introduce main and common items The menu is mainly used to set to enhance characteristics Improper setting may cause the abnormal system operation so please keep factory default settings e CPU Configuration Socket 0 1 CPU Configuration Show the detailed information of CPUO 1 including CPU main frequency size maximum main frequency minimum frequency CPU core number level one cache level two cache level three cache size whether support hyper threading and VT X technology and other information Hyper threading Hyper threading CPU hyper treading function setup includes Enabled and Disabled two items The default setup 1s enabled Active Processor Cores Activate all cores of the CPU including AII 1 2 4 and other items The default is AII ntel Virtualization Technology CPU virtualization technology supports function setup including Enabled and Disabled two items The default is enabled CPU Power Management Configuration Enter this item to manage CPU power co
56. nclude this location in the search then select the path of the driver in the CD driver Expander nf5280m3 and click OK Click lt Next gt to start the installation If it pops up the interface of digital signature messages safety alarm click lt Yes gt to continue the driver installation 9 It will prompt Completing the Hardware Update Wizard and click Finish to finish The installation of Expander card driver is completed 5 3 Manually Install Windows Server 2008 5 3 1 Preparation Prior to the Installation e Windows Server 2008 installation CD DVD here take the installation of 32bit operating system as an example e Inspur driver CD e RAID card drive floppy disk made by Inspur RAID card driver CD for details please refer to the electric version of RAID card driver CD user manual Notes if you use Inspur driver U disk to load controller drive please refer to the attached Inspur Driver U disk Instructions for guide Chapter Five Install Operating System O e Please connect USB floppy drive or Inspur driver U disk before the system starts 5 3 2 Installation Steps 1 Connect USB floppy drive or Inspur driver U disk Power up and start the server Put the installation CD of Windows Server 2008 into the CD drive Enter BIOS settings and make server boot from CD 2 When the system prompts Press any key to boot from CD or DVD press any key If there is no prompt the system will automaticall
57. nsumption Power Technology Include Disable Energy Efficient Custom three items Energy Performance Include Performance Balanced Performance Balanced Energy and Energy Efficient four items e Intel R VT for Directed I O Configuration ntel R VT d Whether Directed I 0 supports Intel virtualization technology or not including Disabled and Enabled two items the default is Disabled e SATA Configuration Enter this item to view the SATA devices connected with each SATA interface SATA Mode This item is used to set onboard SATA controller mode including Disabled IDE Chapter Three System Setup EE Mode AHCI Mode and RAID Mode four items If you want to use serial devices as parallel IDE storage devices when onboard SATA controller is used please set this item to IDE Mode If you do not create RAID and want to connect 1 2 SATA devices when onboard SATA controller is used please set this item to AHCI Mode If you want to create Intel SATA HostRAID when onboard SATA controller is used please set this item to RAID Mode only support Windows system at this time Serial ATA Controller 0 This item only appears when SATA Mode option is set to IDE Mode At this time it supports 2 SATA 3 0Gb s devices when set to Enhanced Under the Windows 98 NT 2000 MS DOS system this item needs to be set to Compatible which can support 2 serial devices at this point e USB Configuration This
58. nterface of SATA HostRAID and will display the created RAID volume in the RAID volume II Delete RAID Volume menu After entering the configuration interface of SAS RAID it can select the menu by up and down arrows and then press Enter key to enter the menu of Delete RAID vol ume or input the number key before menu to enter the menu of Delete RAID volume System warning Deleting a volume will reset the disks to non RAID ALL DISKS DATA WILL BE DELETED If it confirms to delete RAID volume please press lt DEL gt key and the system will pop up again the warning ALL DATA IN THE VOLUME WILL BE LOST Are you sure you want to delete Volume Y N and if yes please enter Y if not please enter N III Reset Disks to Non RAID menu After entering the configuration interface of SAS RAID we can select the menu by up and down arrows and then press Enter key to enter the menu or enter directly The system will display all hard disks in RAID volume Please select hard disks QD Chapter Four SAS RAID Setup to be reset by Space key based on actual demand and then reset hard disk by pressing Enter key The system will again warn whether there is a need to reset the hard disk and enter Y or N according to the promotes It should note that when resetting the hard disks all data on hard disk will be lost and at the same time the hard disk will never again belong to RAID volume IV Exit menu After entering th
59. o 2011 pin slots Processor type Chipset type PCH Memory type DDR3 Unbufferd ECC Registered memory RAM slot number 24 RAM capacity Up to 192GB 8GB per TO Interface 4 rear USB interfaces 2 front USB interfaces Serial interface One rear serial interface one built in serial interface USB interface Network interface 2 Gigabit network card interfaces and 1 management interface 1 front VGA interface no front VGA interface with 17 24 piec Display interface es of HDDs 1 rear VGA interface UID interface 1 UID blue and UID button Display controller Controller type Onboard AST2300 display controller 16MB video memory SAS Back plane SAS2 0 back plane Support hot plug SAS SATA hard disk Network card Network controller Integrated 1 Intel 82576EB two Gigabit network cards Management chip Chapter Two Product Introduction Management chip Integrated A speed 2300 chip support BMC and KVM func tions PCI expansion slot Expansion slot is inserted by riser card And the standard con figured riser cards specifications are Left riser card Support 3 PCI E 2 0 x8 slots Left riser card supports 2 full height amp full length as well as 1 half length amp low profile board cards configuration with two CPU Right riser card Support 1 PCI E 2 0 x16 1 PCI E 2 0 x8 slots Right riser card supports 2 full height amp full length board card only configuration with two CPU
60. oduct Version 00001 Product Serial Number 00001 Product Asset Tag Inspur0001 Board Manufacturer Inspur zd Manufacture Date Time Sun Jan 1 09 21 00 2012 I m r 3 Server Health menu In this menu data information relating to server health including Sensor Read ings Event Log and System and Audit Log can be checked D Sensor Readings menu shows all Sensor values which are mainly tempera ture voltage and fan speed It can refresh and display according to category Chapter Six Instructions for Motherboard Management Controller HE 2 Event Log menu displays sensor events BIOS events system management software events OEM events and remote console software event logs It can display according to category or display uniformly The user can view logs anytime and also can clear logs 8 System and Audit Log menu displays system log and check Log System log needs displaying according to category 4 Configuration menu nin FRU Information Server Health Configuration Remote Control Maintenance Dashboard Active Directory Active Directory Settings DNS LDAP The Active Directory is currently disabled To enable Active BIUSITECS er settings Click on Advanced Settings button NCSI The list below shows the current list of configured Role Grd the list and press Delete Role Group or Modify Role Group Group plete or modify a role group select the name in Network b
61. omatically search driver install automatically after finding it If the system pops up Safety warning click Yes to continue It will prompt Completing the Hardware Update Wizard and click Finish GD Chapter Five Install Operating System to finish the installation of equipment driver of Microsoft Generic IPMI Compliant Device 6 Install Expander card driver When the machine you purchased is configured with Inspur Expander card and the operating system you used is Windows Server 2003 it necessitates the Expander card driver under the load system and the load method is as follows D Enter Windows system click in turn Start Programs Administrative Tools gt lt Computer Management Q In the interface of Computer Management open Device Manager 3 Select Other devices and double click then select LSI CORP Bobcat SCSI Enclosure Device click the right button of the mouse and select Update Driver 4 The window Welcome to the Hardware Update Wizard will pop up If the system inquires Can Windows connect to Windows Update to search for software select No not this time and click lt Next gt The window Hardware Update Wizard will be shown select Install from a list or specific location Advanced and click to continue Insert Inspur driver CD into the CD drive select Search for the best driver in these locations then select I
62. ompt The user s password must be changed before logging on for the first time Click lt OK gt and take out the installation CD According to the prompt in the interface set new password in the password input box and press Enter to continue If the password meets the re quirements it will prompt Your password has been changed And then click lt OK gt to log into the system 2 After logging in the system select Do not show this window at logon at the bottom of the Initial Configuration Tasks interface and then click Close In the new interface of Server Manager select Do not show this console at logon and close the interface 3 Install chipset patch Insert Inspur driver CD into CD drive input the navigation code on the driver CD case in the navigation code verification interface popped out after the operation of CD and click OK to enter the installation interface automatically 2 In Select OS column select Windows 2008 3 In Select Hardware column select Chipset patch 4 Click lt Next gt to start the installation 5 Enter the interface of Welcome to the Setup Program and click lt Next gt to continue the installation Enter the interface of License Agreement and select Yes to continue the installation 7 Enter the interface of Readme File Information and click Next to con tinue the installation 8 The installation program begins to install
63. paces on the computer and click Drive options to start the operation of disk partition In disk partition interface be able to do the following operation It can delete the existing partitions by selecting the existing partitions and then clicking Delete It can format the partitions by selecting the existing partitions and clicking Format It can create new partitions by selecting unallocated disk spaces and then click ing New to create new partitions You can operate according to the actual demands Here we d expound on the issue when there are no existing partitions in the disk D Select the unallocated space click lt New gt delete the number in the Size input box then input the size you want to create unit MB and click lt Apply gt to continue Notes we suggest the partition should be larger than 30GB Select the newly created disk partition then click Format and click lt OK gt Chapter Five Install Operating System EE at the prompt confirmation interface 3 After formatting the partition click lt Next gt to continue 10 The system starts to install Windows and it will complete operations of Copying files Expanding files Installing functions Installing updates and Completing installation etc In this process the system may automatically reboot for several times 5 3 3 Install Drivers 1 After the installation and before logging into the system there is pr
64. r 2003 32 bit and then press Enter to load driver The system starts loading the driver after the driver is loaded press Enter to Chapter Five Install Operating System EE continue to install according to the on screen prompts 4 The system displays Welcome to Setup This portion of the Setup program prepares Microsoft R Windows R to run on your computer To set up Windows now press ENTER To repair a Windows installation using Recovery Console press R To quit Setup without installing Windows press F3 Here we default it as the installation for the first time so choose to press Enter to continue installation 5 The system displays Windows Licensing Agreement The user can read the licensing agreement by pressing lt Page Down gt key After finishing the reading or not reading the agreement you can directly press F8 key to accept the agreement 6 The system displays The following list shows the existing partitions and unallocated space on this computer Use the UP and DOWN ARROW keys to select an item in the list To set up Windows on the selected item press ENTER To create a partition in the unallocated space press C To delete the selected partition press D You can select the items based on the actual situation select the unallocated space here and then press lt C gt key Notes if the Inspur driver U disk is used to load hard disk controller driver please first refe
65. r to attached Inspur Driver U Disk User Manual to delete the disk letter occupied by Inspur driver U disk 7 Program installation prompts To create the new partition enter a size below and press ENTER To go back to the previous screen without creating the partition press ESC The minimum size for the new partition is 8MB The maximum size for the new partition is XXXMB XXX means the maximum capacity of the disk Create partition of size lt unit MB gt Press Backspace to delete the numeral in the frame input the size of the disk partitions you want to create and then press Enter to continue GD Chapter Five Install Operating System Notes it is suggested that the partition should be more than 10GB 8 The system displays the interface of Step 6 here select the partition of Partition New lt Raw gt and press Enter key to continue the installation 9 System displays The selected disk partition has not been formatted and the installation program will immediately format this disk partition Use the UP and DOWN ARROW keys to select the file system needed and then press Enter To select different disk partition for Windows press Esc Format the partition using the NTFS file system Quick C Format the partition using the NTFS file system Select Format the partition using the NTFS file system it is suggested to use and press Enter to format the disk partition 10 The system display
66. rl Alt Del gt to login Input the user name and password and click lt OK gt After logging in the system click Finish if the system prompts the interface of Windows Server Post Setup Security Updates and then click Yes in the dialog box Select GD Chapter Five Install Operating System EE ae Don t display this page at logon in the interface of Manage Your Server and close the windows interface 2 Install Chipset patch CD Insert the Inspur driver CD into CD drive input the navigation code on the driver CD set in the navigation code verifying interface popped up after the running of CD click lt OK gt and it will enter the installation interface automatically In column Select OS select Windows 2003 3 In column Select Hardware select Chipset patch 4 Click lt Next gt and begin the installation Enter the interface of Welcome to the Setup Program and click lt Next gt to continue the installation Enter the interface of License Agreement and select Yes to continue the installation 7 Enter the interface of Readme File Information and click lt Next gt to con tinue the installation The program starts to install and show installation progress after the comple tion of installation click lt Next gt to continue the installation 9 Setup is Complete click Finish take out the Inspur driver CD and restart the system 3 Install Network card driver C
67. roduct configuration and specification details please con tact your supplier 2 If there is system problem in using the machine please contact the customer service center of Inspur server directly please record the product serial number on your host chassis After receiving your service request our technical support personnel will provide you with solution or field maintenance 3 Contact method of customer service center of Inspur server Email sv_str_pcs inspur com Download address of drive and product information for Inspur server http www inspur com support Channel_ Home support sv asp Chapter Eight Server Installation Guide EE Chapter Eight Server Installation Guide e The Guide will help you to understand how to install Inspur 2U server in Inspur server cabinet or compatible standard industrial cabinet e After installing the server in the cabinet according to the Guide please refer to other accompany material to acquire more application directions e Please uncover the film on the cover plate of the server and then power up to use it e Pictures in the Guide just for reference please give priority to real products 8 1 Cabinet Preparation Angle rail adjustment in order to guarantee the 2U server can be installed in the cabinet normally the clearance between the front and rear part of the angle rail should be adjusted to be at least larger than 740mm Leveling cabinet the cabinet must be installed in a stable plac
68. s can support x8 slot Hard disk Hard disk type External storage drive CD drive 2 5 SAS and SATA hard disk Slim SATA DVD drive the server with 17 24 hard disks can not be configured with Slim DVD drive Driver U disk Optional driver U disk Power supply Specification 600W and above 1 1 redundancy Power input Please refer to the power input label on the host nameplate Physical dimensions Package box outer size W Width 966mm H Height 636mm D Depth 409mm Main chassis size W Width 432mm H Height 88 mm D Depth 745mm Product weight Standard configuration 3 hard disks Main chassis weight 19 5 kg Gross weight 32kg include main chassis package box guide rail accessories box Full configuration 24 hard disks Main chassis weight 25 8 kg Gross weight 36 75kg include main chassis package box guide rail accessories box Chapter Two Product Introduction Environment parameter Operating environ 10C 35 C ment temperature Storage and trans port temperature AE Gr Operating humidity 35 80 relative humidity Storage and trans port humidity 2 2 Front Panel View Notes The pictures are for reference only please refer to your actual machines 20 93 40 C relative humidity e Front panel view Tp RI pic Bic rb li 5r 660060000 Number Name Introduction 1 Front USB interface For connecting
69. se driver j inspur S SERV ER gt EXPECT Select OS Windows 2003 0 O OOIS Select Hardware inte sata hostraid 32bit Wnii 4 After you select the corresponding operating system and the controller driver to be made according to the actual need click Next button and make corresponding driver Different operating systems correspond to different making interfaces and meth ods of the driver e Driver making of Windows system When the driver of Windows operating system is made copy the driver directly Chapter Five Install Operating System o D into the simulation floppy drive A of Inspur driver U disk Select the Windows version to be installed and driver to be made and then click Next The system will display a prompt as shown in the following picture Please con firm that Inspur driver U disk is well connected and format the floppy A of Inspur driver U disk and then click OK to start the driver making Make Driver Inspur driver U disk 1 xj Please insert Inspur driver U disk or Floppy Disk and quick format lt a gt disk firstly After the driver making is completed the system will pop up the window prompt ing Driver has been completed and click lt OK gt to complete the making of driver Make Driver Inspur driver U disk xj Driver has been completed e Notices for using Inspur driver U disk to load drive under windows system Durin
70. ss method to IPMI man agement dedicated interface IP address IP address subnet mask and router IP address and other information 5 Boot menu Boot menu is mainly used for system setup and priority settings of system boot devices e Quiet Boot This menu includes Enabled and Disabled two items If the system is set to Disabled it shows normal self check information when system boots If the system is set to Enabled it Shows OEM LOGO instead of self check information eBoot Option 1 2 Enter this menu and select certain boot order device item Press Enter button and the system will display optional boot device table Then select a device through ar row key in the table and press Enter to finish the setting of the boot order item e Hard Drive BBS Priority Press Enter to enter the sub items of this menu to setup the boot order of the devices 6 Security menu e Administrator Password This menu is used to setup system administrator password After the setup of the administrator password you must input the password when enter the BIOS setup prog ress e User Password This menu is used to setup user password After the setup of the user password you must input the password when boot and enter the BIOS setup progress In the setup interface of BIOS Setup you have the same authority to administrator after entering the password QD Chapter Three System Setup ENEN eee 7 Save amp Exit menu The options i
71. t Yes for confirmation the system will load system default optimization setup and the system will not exit the BIOS setup This menu function can use F9 shortcut key to realize e Save as User Defaults Select this item and press Enter After you select Yes for confirmation the system will save the current items setup values of the BIOS as the user default value e Restore User Defaults Chapter Three System Setup HE Select this item and press Enter After you select Yes for confirmation the system will load user default menu e Boot Override Select the device item of this menu After you select Enter for confirmation then it will boot system from the selected device 3 2 Motherboard Jumper Settings Motherboard jumper setting is the operation of shorting cut two pins of the jumper to change the interface functions Refer to the following figure and adjust the mother board functions Connector E n m Jumper Cap 3 2 1 Setting Pin 1 2 short Figure of jumper settings Open the Chassis Upper Panel If motherboard jumper change is needed please get the authorization of Inspur Group Co Ltd according to the methods as follows to open the chassis upper panel 1 Power off the system turn off the AC power then loosen the screws fixed on the upper panel of the chassis 2 Loosen the screw built on the rear point of the upper panel of the chassis 3 Remove the upper panel according to arrow in the picture
72. tall or upgrade an existing system Install system with basic video driver Rescue installed system Boot from local driver Be able to use Tab key for selecting items Here we default it as the installation for the first time Select Install or upgrade an existing system and press Enter to continue installation 3 System prompts Disc Found to begin testing the media before installation press OK Choose Skip to skip the media test and start the installation Select Skip to evade the disk detection and press Enter to continue the instal lation 4 Enter RED HAT ENTERPRISE LINUX 6 interface and click Next to continue the installation 5 System enters interface What language would you like to use during the instal lation process Select the language needed to use during installation Here we select English English and then click lt Next gt to continue 6 Enter interface Select the appropriate keyboard for the system Select key board type according to the actual situation Here we select U S English and click lt Next gt to continue the installation 7 The installation program enters What type of devices will your installation involve Basic Storage Devices Installs or upgrades to typical type of storage devices If you re not sure which option is right for you this is probably it Chapter Five Install Operating System EE Sh Specialized Storage Devices Installs or upgrades to enterprise d
73. the double screw bolt slightly loose the four screws and then push the inner rail again After the inner rail is clamped tightly screw down Picture 5 5 Repeat step 1 4 install the other inner rail in the corresponding position at the other side of the cabinet 8 4 Install Guide Rail into Cabinet 1 Make sure the installation location of the guide rail on the cabinet firstly let the bearing stubs of the front frame pass through the fixed hole of the cabinet s angle rail picture 6 Based on the depth of the cabinet properly adjust the back frame and fix the bearing stubs of the back frame to the angle rail at the back of the cabinet Notice the front and back frame must be guaranteed at the same level Chapter Eight Server Installation Guide Picture 6 2 Find out the screw accompanied with guide rail picture 7 fix well the second hole picture 6 on the front and back frame corresponding to angle rail Picture 7 3 Repeat the above operation install the other guide rail to the cabinet 8 5 Install the Server to Cabinet 1 Raise the server and carry it close to the cabinet and align the back of the serv Chapter Eight Server Installation Guide E er with the front of the cabinet 2 Clamp the inner rail at both sides of the server into the outer rail groove of the cabinet the sliding bead of the outer rail must be moved to the front end of the outer rail 3 Refer to picture 8 keep the server hori
74. tion of management function that management controller integrates 6 1 Management Chip BMC IP Onboard IPMI management card IP can be checked and set in the menu of Server Mgmt BMC network configuration Lan channel 1 2 Station IP address in the BIOS Notes Lan channel 1 refers to the multiplex management network interface 82576 net work card 1 interface Lan channel 2 refers to IPMI management special interface Please set or view IP address according to the actual use of the network card If you reset IP address of IPMI card only after saving and restarting the server or powering off disconnecting the power can you make it into normal use 6 2 Remote Login 1 Remote client system requirements The requirements of remote client system of GUI interface connecting to the serv er management chip through web browser are shown in the following table Requirements Remote web control console client Support the operating system of Microsoft Operating System Internet Explorer browser Br veludtcmodul Install Java SE Runtime Environment 6 sia ae satis Updata 12 or higher version TCP IP network protocol stack Support TCP IP network protocol stack The browser plug in download address Java SE Runtime Environment http www java com en download Chapter Six Instructions for Motherboard Management Controller EE You can also use Inspur driver CD Enter Java directory under CD root directory here
75. uctions for Motherboard Management Controller s admin Adminis sh S2 Print Logout Dashboard FRU Information Server Health Configuration Remote Control Maintenance HELP Power Control and Status The current server power status is shown below To perform a power control operation select one of the options below and press Perform Action Host is currently on Reset Server Power Off Server Immediate Power Off Server Orderly Shutdown Power On Server Power Cycle Server Power Control menu displays the current power state of server providing reset server power off server immediate power off server orderly shutdown power on serv er and power cycle server After selecting the option to execute click Perform Action to execute 8 Remote Control Function menu Select Remote Control Function menu and enter the interface shown in the fol lowing figure admin strat Refresh Print Logout Dashboard FRU Information Server Health Configuration Remote Control Maintenance HELP Remote Control Function List The current support function is shown below To perform a control operation select one ofthe options below and press Perform Action Light on UID Light off UID Select Light on UID option and click Perform Action to execute After that ID light of front and back panel of corresponding server will be on Select Light off UID option and click
76. y into the floppy drive Click Browse item in the Loader Driver window and in the pop up prompt interface select the drive Floppy Disk Drive A where the driver is located GD Chapter Five Install Operating System Click Yes to continue 8 The system will search the driver automatically In the interface of Choose to install the driver click lt Next gt to continue After the completion of the drive loading it will show disk detected The load of HDD controller driver is completed If Inspur driver U disk is used D Please make the HDD controller driver in the Inspur driver U disk 3 5 floppy disk A partition 2 When powering up and starting the server to install operating system please connect Inspur driver U disk to the USB interface of the server 3 In the interface of Where do you want to install Windows select Load Driver 4 The system pops up the window to prompt please insert the installation media containing the driver file Here directly select lt OK gt 5 The system will display the driver list detected Please select the driver to in stall Here use the default selection and click lt Next gt to continue 6 After the completion of the drive loading it will show disk detected The load of HDD controller driver is completed 9 The system enters the interface of Where do you want to install Windows It will display the existing partitions and unallocated s
77. y start Windows installation pro gram from CD 3 In the language setting interface select and set the language and other options needed to install according to the actual needs Then click lt Next gt to continue 4 Click Install now to continue in the installation confirmation interface 5 If selecting Online automatically activate Windows under the key after three days since you log in for the first time automatic activation will begin to try to activate your Windows after installing Windows you have 30 days to activate Windows online or through the phone If the deadline of 30 days has come before you complete activa tion Windows will stop running 6 The Microsoft software license clauses will be shown in the interface of Please read the license terms Select I accept the license terms after reading and click lt Next gt to continue 7 Select the installation type and here we default it is the first installation Select Custom mode to continue 8 The system enters the interface of Where do you want to install Windows It will display the existing partitions and unallocated spaces on the computer if there is no need to load HDD controller driver RAID card configuration needs us to manually load HDD controller driver If USB floppy is used First finish making the driver floppy When powering up and starting the serv er please connect the floppy to the USB interface of the server and insert driver flopp
78. you provided Input your full name and the name of the company or organization Name Organization The user can fill in according to his actual situations and then click lt Next gt to continue the installation 14 Input your Product Key 25 character and then click lt Next gt to continue the installation 15 Licensing Models Windows Server 2003 supports two licensing models Per server Number of concurrent connections V Each connection must have its own Client Access License Per Device or PerUser S Each device or user must have its own Client Access License The user can select and set according to his demands and then click lt Next gt 16 Input Computer Name and Administrator Password You must provide computer name and administrator password After setting the computer name not more than 15 characters and administrator password not more than 14 characters based on the actual situation click lt Next gt to continue the installation 17 Date and Time Settings After setting the correct date and time click lt Next gt to continue the installation 18 The installation program starts to install start menu and register components as well as execute the last series of relevant task the process requires a certain period of time 19 After the installation the system will restart automatically 5 2 3 Install Driver 1 After the restart of the system take out the installation CD and press lt Ct
79. zontal and push it steadily into the cabinet If it is blocked during the pushing pull forward the bayonet lock at the front of the inner rail and at the same time push it into the cabinet Picture 8 4 Use fixed screw picture 7 to fix the server to the cabinet through the third hole picture 9 in the front of guide rail corresponding to angle rail A Special notice if the third hole screw is accompanied with the cabinet front panel you may use the accompanying screw to fix the server to the cabinet in this operation the third hole Fixed server sc Picture 9
Download Pdf Manuals
Related Search
Related Contents
WEPA 245 SER.R2 カタログPDF Fujifilm FinePix F650 User`s Manual CG-1800/CG-1000 Owner`s Manual Télécharger English(4401) - m Aparelho de Pressão Digital G-Tech LA250 – G-TECH Bedienungsanleitung - STB Schweisstechnik Copyright © All rights reserved.
Failed to retrieve file