Home

User`s Manual

image

Contents

1. amp pric s User s Manual For M1 201SA TR Manual Contents Manual Contents Welcome Product Description System Requirements for Setup Installation Troubleshooting Maintenance Technical Support Product Specifications Warranty Information Regulatory Statements Pictorials Figure 1 Optical DVI Extension Module System Figure 2 Auto EDID button Figure 3 Connection of optical fiber 1 0 Manual Contents e lr cee Cee Gil Ga EO lt A DGEWEN O ak eh ek Ko Welcome Congratulations on your purchase of the Stretch DVI M1 201SA TR Optical DVI Digital Visual Interface Extension Module This manual contains information that will assist you in installing and operating the product Product Description The M1 201SA TR optical DVI module transmits four 4 optical data Red Green Blue and clock and can be extended up to 500 meters 1 640ft over a pair of LC duplex multi mode fibers or four 4 LC simplex multi mode fibers at WUXGA 1920x1200 at 60Hz vertical refresh The EDID Extended Display Identification Data in a display can be read and restored by just plugging once transmitter to the display This Auto EDID programming feature makes the installation of M1 201SA more easy and flexile at any variable resolution display systems For your convenience UXGA EDID would have been done before shipment as a default Shipping Group o M1 201SA TR Optical DVI Extension Module One 1 pair O DC po
2. the power jack of the transmitter and connect the adapter to the mains electricity Ensures the blue LED ON Step 2 For Auto EDID programming a Push the Auto EDID button with a narrow pin After twice blinking of Blue LED it will be turned off b Connect the powered transmitter to display while turned on not to the PC The LED blinking indicates reading the EDID LED OFF after blinking notices programming done c Disconnect the transmitter from the display Then LED ON again UM Figure 2 Auto EDID button Note If you want to change the display please do again the step 2 The default EDID in factory ship out is programmed in the VESA standard of UXGA 60Hz Step 3 Plug directly the transmitter module to DVI receptacle of PC and confirm if the blue LED ON Or connect 5V power adapter to the power jack of the transmitter Note Be recommend NOT to use any intermediate cable or adapter between them to avoid undesirable performance degradation Note If you use laptop or Desktop PC with PCI Express graphic card we recommend using 5V power adapter for the transmitter Note Please DO NOT look directly into the LC receptacles of the Transmitter while it is powered on although this product is regulated strictly enough to operate under the LASER Class I classified by CDRH FDA for eye safety 1 3 Installation Step 4 Connect another 5V power adapter to the receiver Then blue LED ON Step 5 Plug the rec
3. this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product 1 7 Warranty Information 2009 Opticis Co Ltd All Rights Reserved UL IEC Statement Revision 2 2 Nov 26 2009 This equipment has been tested and found to comply with the limits for medical devices in IEC 60601 1 1994 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to other devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Opticis Locations Headquarters e Reorient or relocate the receiving device e o Increase the separation between the equipment Connect the equipment into an outlet on a circuit different from that 304 Byucksan Technopia 434 6 to which the other device s are connected 7 Sangdaewon Dong Chungwon Ku e Consul
4. eiver to the DVI receptacle of display Note Be recommended NOT to use any intermediate cable or adapter between them to avoid undesirable performance degradation Step 6 Connect each LC multi mode fiber one by one as shown in figure 3 Transmitter Receiver Fa Jik fe Figure 3 Connection of optical fiber Step 7 Makes the PC Power On Step 8 Go to Display Properties in Windows systems and click the tap of Settings Then you can set the right display resolution to meet your display Once you set the right resolution you could see displaying the initial screen at the same resolution as just before you powered on Note If you cannot see the initial screen of the OS system and have skipped the Step 1 and Step 2 you have to follow the Step 1 and Step 2 instructions Step 9 You can see processing to adjust the system screen 1 4 Installation continued Troubleshooting The display displays only black screen Ensure that all plugs and jacks used by external power supplies both Opticis and others are firmly connected Ensure the blue LED ON Ensure that the DVI ports are firmly plugged in to the PC and display Ensure that the transmitter and receiver modules plugged correctly to the PC and display respectively Check if the PC and display are powered on and properly booted Reset the system by de plug
5. ging and re plugging the transmitter DVI port or receiver DVI port or by de plugging and re plugging the power cord plugs of transmitter and receiver modules Re boot up the system while connecting the optical DVI extension module Screen is distorted or displays noises Check if the graphic resolution is properly set Go to the display properties of Windows and tap the settings Ensure that the resolution sets less than WUXGA 1920x1200 at 60Hz refresh ratio Reset the system Disconnect and reconnect the optical DVI cables or 5V power adapters Maintenance No special maintenance is required for the optical DVI module and power adapters Ensure that the DVI modules and power adapters are stored or used in a benign environment free from liquid or dirt contamination There are no user serviceable parts Refer all service and repair issues to Opticis Technical Support and Service For commercial or general product support contact your reseller For technical service contact Opticis by email techsupp opticis com or visit its website at www opticis com 1 5 Troubleshooting Maintenance Technical Support Product Specifications M1 201SA TR Optical DVI Extension Modules O Compliance with DVI standard Supports DV11 0 fully implemented by fiber optic communication and DDC2B by virtual DDC Extension limit 500m 1 640feet for WUXGA 1920x1200 at 60 Hz refresh rate Graphic transmission bandwidth Support
6. icis Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the reminder of the initial warranty period whichever is longer Opticis shall not be responsible for any software firmware information or memory data of customer contained in stored on or integrated with any products returned to Opticis for repair under warranty or not Warranty Limitation and Exclusion Opticis shall have no further obligation under the foregoing limited warranty if the product has been damaged due to abuse misuse neglect accident unusual physical or electrical stress unauthorized modifications tampering alterations or service other than by Opticis or its authorized agents causes other than from ordinary use or failure to properly use the product in the application for which said product is intended Dispose of Old Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate systems This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative r consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of
7. s up to WUXGA at 60Hz or 1 65Gbps bandwidth per graphic channel Fiber optic connection The transmitter and receiver modules of M1 201SA TR have two 2 duplex LC receptacles so as to be connected with two 2 LC duplex multi mode fiber having 62 5 125um or 50 125um core DDC connection Virtual DDC by Auto EDID programming Mechanical specifications of transmitter and receiver modules m Dimensions 39mm 15mm 59mm W H D Environmental Specifications m Operating temperature 0 C to 50 C M Storage temperature 30 C to 70 C m Humidity 0 to 85 AC DC Power Adapter Oo oO o Power Input AC 100 240V 50 60Hz 1 2A Power Output 5 V 2A SMPS DC power Adapter Cord DC Jack Core is 5 V and outer is GND Manufacturer Ault Korea Corporation 1 6 Product Specifications Warranty Information 1 One Year Warranty Opticis warrants this optical DVI extension module to be free from defects in workmanship and materials under normal use and service for a period of one 1 year from the date of purchase from Opticis or its authorized resellers If a product does not work as warranted during the applicable warranty period Opticis shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of Opt
8. t the manufacturer or field service technician for help Sungnam City Kyungki Do 462 716 South Korea Opticis Co Ltd e Type of protection against electric shock Class equipment e Degree of protection against electric shock Not classified no applied Tel 82 31 737 8033 8 parts Fax 82 31 737 8079 e o Classification according to the degree of protection against ingress of www opticis com water as detailed in the current edition of IEC 529 IPXO ordinary equipment e This equipment is not suitable for use in the presence of flammable anesthetics or oxygen e Mode of operation continuous operation Certification of Eye Safety This laser product is inside implemented by using 1300 1550nm optical module manufactured by Opticis Co Ltd which are all certified by IEC EN60825 1 referred in Accession Number 07 1334 0217 as classified in Laser Class1 CLASS 1 LASER PRODUCT For technical support check with the Opticis web site www opticis com or 1 8 Regulatory Statements contact techsupp opticis com For order support please contact your Distributor or Reseller
9. wer adapter Two 2 units o Users Manual Figure 1 Optical DVI Extension Modules System 1 1 Welcome Product Description System Reguiremenis for Setup O Hardware requirements m You have to have a DVI graphic controller or card having a DVI port in your PC SUN or Mac systems It should support the maximum graphic resolution feature of displays to be connected m No special requirements for memory size CPU speed and chipsets if you ve already properly installed your DVI graphic controllers or cards O Software requirements m No special restrictions if you ve already properly installed your DVI graphic controller in your OS o AC DC Power Adapter Technical Advisory The transmitter Tx module of M1 201SA TR is designed a power protection circuit from conflict of power supply between the external DC power adapter and your graphic card through the DVI pin However the receiver Rx module should be supplied by an AC DC power adapter Tips In general most of laptops or desktop PCs with PCI Express graphic card require using an AC DC power adapter for the transmitter module Note Recommend to use power supplying adapters offered by Opticis which has short circuit break features 1 2 System Requirements for Setup Installation Important Please use the installation procedure below Improper or no operation may result if the start up sequence is not correctly followed Step 1 Plug the 5V power adapter to