1. gt WO Sune Start port ATS CONTROL MODULE 72 ATS CONTROLLER 2015 04 21 Version 1 2 Page 11 of 11
2. SmartGen DEA ideas for power 2 ATS CONTROLLER USER MANUAL 4 ZHENGZHOU SMARTGEN TECHNOLOGY CO LTD Chinese trademark 5 r t Gen English trademark SmartGen make your generator smart SmartGen Technology Co Ltd No 28 Jinsuo Road Zhengzhou City Henan Province P R China Tel 86 371 67988888 86 371 67981888 86 371 67991553 86 371 67992951 86 371 67981000 overseas Fax 0086 37 1 67992952 Web _hitp www smartgen com cn http www smartgen cn Email sales smartgen cn All 15 reserved No part of this publication may be reproduced any material form including photocopying or storing in any medium by electronic means or other without the written permission of the copyright holder Technology reserves the right to change the contents of this document without prior notice lf colors of actual products are different from those mentioned within this manual please take the actual product as the standard Software Version 2007 12 01 Original release 2015 03 11 Modify some details 2015 04 21 Modify some details Clarification of notation used within this publication nor Highlights an essential element of a procedure to ensure correctness Indicates a procedure or practice which if not strictly observed could Caution result in damage or destruction of equipment Q Indicates error operation may cause death se
3. 0 5 0s 0 ime held until the delay is expended Mains over The setting are used to configure the Mains 0 360 276 voltage power over voltage point Mains under The setting are used to configure the Mains 0 360 184 voltage power under voltage point The setting are used to configure the Gens Gens over voltage 0 360V 264 power over voltage point The setting are used to configure the Gens 0 360V 192 72 ATS CONTROLLER 2015 04 21 Version 1 2 Page 8 of 11 276 184 264 192 SmartGen 72 ATS CONTROLLER USER MANUAL power under voltage point Frequency upper When the frequency of Gens power is over 40 75Hz 55 0 limit than the point over frequency is active Frequency lower When the frequency of Gens power is low 0 60Hz 45 limit than the point low frequency is active Yes or No close Yes Input is connect 5 TERMINAL Terminal 1 connect the cathode of battery Terminal 2 B connect to the anode of battery Terminal 3 Close Generator Input Generator supply closed auxiliary input connect to B is active Terminal 4 5 Generator Start Output output of Relay of start generator volts free 5A250V Terminal 6 7 Generator AC Input Generator AC Input Terminal 8 9 Mains AC Input Mains AC Input Terminal 10 11 Mains Output output of Relay of close mains volts free 16A250V
4. 0 2kg 72 ATS CONTROLLER 2015 04 21 Version 1 2 Page 6 of 11 ker SmartGen HAT72 ATS CONTROLLER USER MANUAL 4 DISPLAY PANEL AND OPERATING INSTRUCTIONS PUSH BUTTON Symbol At MAN state push this button ATS Close Mains Mains close button will turn to the mains MAN AUTO state Switch the state to MAN AUTO switch button Generator close At MAN state push this button ATS Close Gens button will turn to the Generator LED Lighten when mains is normal Flicker Mains Mains normal led when mains 16 abnormal Die when Normal ae mains 15 lost Mains Closed Mains closed led Lighten when mains load Lighten when Generator is normal Gens Normal Generator normal led Flicker when Generator is abnormal Die when mains 15 lost Gens Closed Generator closed led Lighten when Generator load Operating Module has two states MAN state and AUTO state the state can be switch by MAN AUTO button the state can be display by Auto state led and Man state led MAN state When Man state led is lighten the module is at man state Here push CLOSE Mains button the relay of close mains will output push CLOSE Gens button the relay of close Generator will output At this state the relay of start generator is unable AUTO state When Auto state led is lighten the module is at auto state When mains is normal 72 ATS CONTROLLER 2015 04 21 Version 1
5. 2 Page 7 of 11 SmartGen 72 ATS CONTROLLER USER MANUAL ATS will turn to the mains after the Mains Normal delay time When mains is abnormal under voltage over voltage lost voltage after the Mains Abnormal delay time and Start generator time the relay of start generator will output and the generator will start If the Generator is normal ATS will turn to the Generator after the Gens Normal delay time When mains is normal ATS will turn to the mains after the Mains Normal delay time When mains is normal the relay of start generator will be unable and the generator will stop after the Stop generator time Parameters table only adjust via PC Description Range Default Mains normal It is the delay of Mains power from 0 3600s 10 delay abnormal to normal Gens normal It is the delay of Mains power from 0 3600s 10 delay abnormal to normal Mains abnormal It is the delay of Mains power from normal 0 3600s 5 delay to abnormal the delay from Mains power 15 Start GENS Delay 0 3600s 1 abnormal to send out start generator signal is the delay from Mains power is normal Stop GENS Delay 0 36008 5 to send out stop generator signal Breaker close pulse If it is set to zero the ATS close time 0 20 05 5 0 output will held 1 Transferresttime 08600 After the module has received a close state Exceed Converti input the breaker close output continue to
6. Terminal 12 13 Close Generator Output output of Relay of close generator volts free 16 250 Terminal 14 Close Mains Input Mains supply closed auxiliary input connect to B is active Terminal LINK connect to PC by SG72 72 ATS CONTROLLER 2015 04 21 Version 1 2 Page 9 of 11 SmartGen ideas for power HAT 72 ATS CONTROLLER USER MANUAL 6 CASE DIMENSIONS cutout 67 67mm 66mm 72mm ose Gens ir ninal 3 14 Is active connected B m erminal 4 5 10 11 12 13 relay output 66mm 72mm Termin 1 7 TYPICAL CONNECTIONS SGQ N T TYPE SWITCH LOAD 12 13 Mains Gens 4 _ _ eee V T _ W N E N m ea lt o lJ J N L N Gens voltage input Mains voltage input Close Mains Close Gens Mains Close input Gens Close input ATS CONTROL MODULE HAT72 ATS CONTROLLER 2015 04 21 Version 1 2 Page 10 of 11 SmartGen apt tet HAT72 ATS CONTROLLER USER MANUAL SGQ M TYPE SWITCH LOAD L1 L2 L3 Mains Gens 5 st gt lly N a SWITCH 2 a ae input Maing Close Close Mains Gens battery Gens Close input 5 9 O
7. nt voltage environments of start battery Mains or generate normal delay can be set genset start delay can be set Mains abnormal delay can be set genset stop delay can be set 7 LEDs display the status of operation and alarm Transfer relay CLOSE MAINS CLOSE GENS output contact rating 16 250 passive contact directly drive the switch to transfer Start relay GENS START output contact rating AC250V passive contact Close output can be set to continuous close or pulse close when pulse close is initiated close delay can be set Providing PC programming port which all delays power thresholds needed by ATS can be set via PC Built in never halted watch dog to ensure smooth program execution Modular design self extinguishing ABS plastic shell pluggable terminal built in mounting compact structure with easy installation 72 ATS CONTROLLER 2015 04 21 Version 1 2 Page 5 of 11 SmartGen 3 TECHNICAL PARAMETERS DC power 8 35 V 72 ATS CONTROLLER USER MANUAL sampling input single phase 30 277 20 50 60 2 ATS switch output 16A AC250V relay passive contact Genset start output 5A AC250V relay passive contact 2 close input ports active when connected to B Consumption standby 12V 0 12W 24V 0 24W working 12V 1 5W 24V 1 6W Working conditions Temperature 30 70 Humidity 20 95 Case dimensions 72 72 52mm Cut out 67 67mm Weight
8. rious injury and Warning significant property damage SmartGen ideas for power HAT72 ATS CONTROLLER USER MANUAL CONTENT 1 5 2 PERFORMANCE AND 58 8 44 1 5 3 TECHNICAL 8 40440 6 4 DISPLAY PANEL AND OPERATING 7 niL 9 6 CASE DIMENSIONS cutout 67 67MM 2224114 10 7 TYPICAL CONNECTIONS ccccccscsessessessesecsesseseesecseseesecsssesetsessessesetetseeeeeeees 10 72 ATS CONTROLLER 2015 04 21 Version 1 2 Page 4 of 11 SmartGen ideas for power HAT 72 ATS CONTROLLER USER MANUAL 1 OVERVIEW HAT 72 is an Automatic Transfer Switch Control Module for 1 way mains generator which features 8 Bit microprocessor control The module is used to monitor two ways of single phase supply Once mains supply failure under voltage over voltage under frequency over frequency is detected the module will control ATS to switch after delay The controller can send out signal of starting the generator after mains failure delay 2 PERFORMANCE AND CHARACTERISTICS Suitable for 1 way mains and 1 way generator ATS control Widely power supply range DC 8 35 fit with differe