Home
2D Data Processing Unit User`s Manual (Operation Guide)
Contents
1. No 99MBA038A 4 1 Operating Procedures Table 4 1 1 Operation Screen display and remarks Preparing the workpiece Set the model workpiece on the XY table as shown below and focus on it Aligning the part coordinate system The explanation for the operations from For the aligning procedure see Section 3 2 Aligning step 3 onward assumes that the part Part Coordinate System Using Edges as Reference coordinate system has been aligned Measurement function selection press P Changing measurement conditions Press the F3 function key corresponding to i K 3 Setting Auto MeasuringCompletion to OFF Press the F3 key to set the Auto MeasuringCompletion OFF Auto MeasuringCompletion to OFF Press F3 to switch the status Completion of changing measurement conditions Press the F5 function key corresponding to p Measuring edge A lt Remarks gt Measure edge A at three or more points Follow the information displayed on the screen to perform the measurement 4 2 No 99MBA038A 4 Applied Measurements Operation Screen display and remarks Completing the measurement When two or more measured points required for measuring a line are input is displayed Press the corresponding F5 function key to complete the measurement Results display The measurement results for edge A are displayed on the screen A TIP To perform measurements in such a mann
2. Measurement macro Used to measure and calculate width pitch perpendicularity and other command keys values that are not basic features Function keys LOAD key CANCEL key ENTER key Cursor keys Num eric keys Used to select the icon for a function that can be used in a command which is being executed The keys correspond to icons with function key numbers F1 F2 F5 Used to input a measured point Cancels a measured point or goes back to the immediately previous menu Enters the selection or entry and goes to the next step Used to move the cursor or select a parameter Used to input numerical values such as when entering a nominal value These keys are also used to select menus shown on the LCD Cootainale systen allgninient Used to set or change the coordinate system menu key Soordinats datainparsivic Used to change the coordinate data input style 1 2 No 99MBA038A 1 Before Starting Measurements Table 1 1 1 No 2 Almeasurem ntka s recognizes the type of the measured basic feature and outputs y the results when measured points are input Switches the screen display mode measurement screen counter display screen etc Counter function key Uses the data processing unit as a simple counter Manual print key Prints the measurement results displayed on the screen Executes a previously registered part program or user defined macro command TIP Keys with a letter of
3. as shown below each time a point is entered Ail 1 1 3 2 3 Fig 1 1 5 TIP When the results are displayed at the end of the measurement the navigation window returns to its initial input standby state 1 3 in the above figure and the same measurement is repeated automatically e To perform a different measurement press a different measurement command key 1 4 No 99MBA038A 1 Before Starting Measurements 1 2 Preparing for Measurement Purpose of Practice To learn the operating procedures from turning on the power to getting the state where measurement commands can be executed Operating Procedure 1 Turn on the power for the data processing unit 2 Set the printer output to ON 1 2 1 Turning On the Power Table 1 2 1 No Operation __ _ Screen display and remarks 2 The Startup Screen is displayed A little bit after the opening screen is I displayed the startup screen shown at right is displayed Press a measurement or menu key X 0 000 Y 0 000 EEEE H BEA No 99MBA038A 1 5 1 2 2 Setting Printer Output to ON when printer is connected NOTE Be sure to turn on the printer power before setting the printer output to ON Table 1 2 2 No Operation Screen display and remarks Selecting menu function MENU 1 Output Function Menu 7 MENU 1 9 F Press 0 Selecting printer setting Press the numeric ke
4. to change without notice 2002 Mitutoyo Corporation All rights reserved No 99MBA038A I Introduction Thank you for using the QM Data 200 two dimensional data processing unit This Operation Guide presents a collection of example applications that will help you understand the basic operating procedures using the QM Data 200 Effective use of this Operation Guide will ensure that you use the QM Data 200 correctly and will help you in your measurement work Model Workpiece The model workpiece shown below is used in all the examples presented This model workpiece is designed for practice purposes dimensional precision is not guaranteed Therefore it should be noted that there may be some differences compared to the data in the examples presented 12 i No 99MBA038A Table of Contents CONVENTIONS USED IN THIS MANUAL 0 cccceeeeeeeeeeeeeeeeenceeeeeeeeaeeeeeseeeeeeseaeeeeeseaeeeeaseaeeeeaseeeeeeaseeneeenseneennas i NPAT OCCU ON Se cicied coc Se eee deers ch cts de Seige ed se wens shoe ees aden ease evens OEN se ORANE ENAA ve Veee CAASA NEET NA ii Model Work pie a samc cpscecec te face ech sa Secs fee exis sein yea covey shen nate saci ee TONERA su ce eee saan ei suey neh pueve sober pve AAA ii 1 Before Starting Measurements cccccecceeceseeneeeeeeeneeeeeeeeeeeneeeeeeenseeeeeenseeeeeeeeseeneeenaseeeeeessseeeseseseeesneseenens 1 1 1 1 Outline of Data Processing Unit c
5. to perform the measurement A No 99MBA038A 2 3 No Operation ___Screen display and remarks 4 Measuring edge B lt Remarks gt Measure edge B at two points Follow the information displayed on the screen to perform the measurement Results display The measurement results A1 A2 for the angle formed by edge A and edge B are displayed on the screen A2 AIC A1 150 0142 fe o NOTE Note that the obtained angle A1 varies depending on the order in which the edges are measured as shown below T T gt 4 s Q 4 A g O D Measurement Measurement Measurement Measurement method 1 method 2 method 3 method 4 e The X and Y coordinate results of the intersection point vary depending on the position and orientation of the model workpiece on the XY table In order to obtain measurement results that match the dimensions shown in the section titled Model Workpiece before starting the measurement perform the operation described in Section 3 2 Aligning Part Coordinate System Using Edges as Reference e Angle units can be switched between degrees decimal notation and degrees minutes and seconds sexagesimal notation See Chapter 6 of the Software Guide for the switching procedure 2 4 No 99MBA038A 2 Basic Measurements 2 3 Measuring a Width Purpose of Practice To measure a width using the model workpiece Operating Proced
6. No 99MBA038A SERIES No 264 W SJ Ss Wy Ww NAS A XS D VY W panne S85 SS ANS Manual thoroughly ading at hand for future reference Mitutoyo Read this User s before operating the instrument After re retain it close 2D Data Processing Unit User s Manual Operation Guide CONVENTIONS USED IN THIS MANUAL Types of Notes The following types of notes are used in this manual to help the operator obtain reliable measurement data through correct instrument operation IMPORTANT An important note provides information essential to the completion of a task You cannot disregard this note to complete the task e An important note is a type of precaution which if neglected could result in a loss of data decreased accuracy or instrument malfunction failure NOTE A note emphasizes or supplements important points of the main text It also supplies information about specific situations e g memory limitations equipment configurations or details that apply to specific versions of a program TIP A tip is a type of note that helps the user apply the techniques and procedures described in the text to his or her specific needs It also provides reference information associated with the topic being discussed Mitutoyo assumes no liability to any party for any loss or damage direct or indirect caused by use of this instrument not conforming to this manual Information in this document is subject
7. cccceccceeseneeeeeeeeeeeeeeeeeeeeeeeeneeeeseeeeeeeseeeeeenseeneeenseeeeeeneneeneeens 1 1 TAT SAP POAAaNGe eins si cccccseesssnecectdsenacexedvagscbensedceseivnaseceraetceausveancvergeteesnivaanstesctens cunssneededeeastinies 1 1 1 1 2 Key Pa el Layout serrie iniiae n aea Naa E a RANEA AAAA s AAi 1 2 1 1 3 Elements of LCD Screen sssssusssenunsennnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nenne 1 3 114 Measurement SCree iheiiiie iccccescccccceseccecestcee ccesdsceceavacaececdecuectevacenexesuscerenentecertavaceceeesusdereeeaeee 1 4 1 2 Preparing for Measurement cccecsecceceeeeeeeeeeeneeeeeeceeeeeeeeeeeeeeseeeeeeseaeeeseseeneesaseceneeeaseeneeenseanenees 1 5 1 2 1 Turning On the Power ceceeseceseeeeeeeeeeeeeeeeeeeseeeseeeseeeseeeseseneaaeseseseeeseseseaesesesanseseseanseeesees 1 5 1 2 2 Setting Printer Output to ON when printer is Connected cceseeceeeseeeeeeeeneeeeeeeeees 1 6 2 BaSic Meas rements rivvccscenieecveiceceeecccicetesstedieuaecdeecvectetteesecerttensbedteunentedtvesecesetenstedteuacedreedesbeneeestedteeaeeve 2 1 21 Measuring a Circle sissors edora nkuna te reen ENAKAN KRE KANAA Aa ENAKAN KENANA KEENAN A AK ENAK an KENNEN AKUNA FAA KENA KANK 2 1 2 2 Measuring Angle Between Two Edges scccsssescrssseeeeseeeseeeeeeeeneeseseeneesesesneeseseseeeeeesesneneneesnanes 2 3 23 Measuring a Width essiensa enn nanes nanana ONAA AE Ee aAA AONA nana eS ariaa ERTA AARETE 2 5 2 4 Measur
8. cting the coordinate system alignment menu Y Press 3 2 No 99MBA038A 3 Aligning Part Coordinate System No Operation Screen display and remarks _ 4 Measuring edge A lt Remarks gt Measure edge A at two points Follow the information displayed on the screen to perform the measurement lt Remarks gt Follow the information displayed on the screen to perform the measurement The part coordinate system is completed lt Remarks gt The part coordinate system is completed as shown below Once the part coordinate system is completed coordinate values are defined from the origin which serves as a reference The part coordinate system established in this example matches the coordinate system shown in the section titled Origin Model Workpiece Therefore you can N refer to the drawing in that section while practicing measurements TIP See Chapter 5 of the Software Guide for further details about the coordinate system alignment functions NOTE When measuring edge A note the order in which the measurements are performed as the direction of the coordinate system s reference axis varies depending on the measurement order Y A X x A 1 2 y 2 1 The X axis direction orients from the first measured point to the second measured point No 99MBA038A 3 3 3 3 Aligning Part Coordinate System Using Circle Centers as Reference Purpose of Practice To align the part coor
9. dinate system based on two circle centers using the model workpiece Description of Operation The part coordinate system is set using the coordinate system alignment macro command 4 Operating Procedure Table 3 3 1 Operation No Operation __Screendisplay and remarks____ Preparing the workpiece Set the model workpiece on the XY table as shown below and focus on it Aa Ne Press E The coordinate system alignment function menu is displayed Selecting the coordinate system alignment macro command 4 Selecting the coordinate system alignment menu a Press the numeric key corresponding to 3 4 No 99MBA038A 3 Aligning Part Coordinate System No Operation ___Screen display and remarks 4 Selecting the coordinate data input style Press rN Then from the icon menu press the numeric key corresponding to 6l Measuring circle A Measure circle A at three points 5 RU e C 2 OOO i Measuring circle B Measure circle B at three points 7 The part coordinate system is completed The part coordinate system is completed as shown below Origin OO Y7 No 99MBA038A lt Remarks gt Follow the information displayed on the screen to perform the measurement lt Remarks gt Follow the information displayed on the screen to perform the measurement lt Remarks gt Once the part coordinate system is completed coordinate values are def
10. er as possible on the circumference in order to measure the circle precisely e The X and Y coordinate results indicating the circle s center position vary depending on the position and orientation of the model workpiece on the XY table In order to obtain measurement results that match the dimensions shown in the section titled Model Workpiece before starting the measurement perform the operation described in Section 3 2 Aligning Part Coordinate System Using Edges as Reference TIP If an incorrect position was measured it is possible to cancel the measured point data by pressing the CANCEL key prior to entering the last measurement point If the CANCEL key is held down the system returns to the standby state for the first measurement point e The last measurement point cannot be canceled If the last measurement point is not correct redo the measurement 2 2 No 99MBA038A 2 Basic Measurements 2 2 Measuring Angle Between Two Edges Purpose of Practice To measure the angle between two edges using the model workpiece Fig 2 2 1 Operating Procedure Table 2 2 1 Operation Screen display and remarks Preparing the workpiece Set the model workpiece on the XY table as shown below and focus on it O aJo L EOL Measurement function selection press et Measuring edge A lt Remarks gt Measure edge A at two points Follow the information displayed on the 1 screen
11. er that a multi point measurement is automatically completed when the predetermined number of measuring points have been input reset Auto MeasuringCompletion to ON see steps 4 through 6 e The multi point measurement can be performed using the same procedure on points circles and ellipses in addition to lines No 99MBA038A 4 3 4 2 Selecting and Outputting Required Measurement Items Only Purpose of Practice To practice selecting and outputting just the required items as measurement results In this section the point amp angle feature formed by two adjacent edges is measured to output only the intersection angle A1 Fig 4 2 1 Operating Procedures Table 4 2 1 Operation Preparing the workpiece Set the model workpiece on the XY table as shown below and focus on it Measurement function selection press Mat Starting output item selection Press the F3 function key corresponding to 4 4 No 99MBA038A 4 Applied Measurements No Operation Screen display and remarks 4 Selecting output item Coord _Y X Use the up and down cursor keys N V to RadDist L Angle A highlight the item to be selected Tangle A1 Each time the ENTER key is pressed an asterisk Angle A1 Angle A2 appears to the left of the highlighted item or is removed from the item In this example place an asterisk next to Angle A1 only lt Remarks gt I
12. g the workpiece Set the model workpiece on the XY table as shown below and focus on it O o Ov OO Measurement function selection N Press of i Measuring circle A lt Remarks gt Measure circle A at three points Follow the information displayed on the screen to perform the measurement No 99MBA038A 2 7 Operation Screen display and remarks 4 Measuring circle B lt Remarks gt Measure circle B at three points Follow the information displayed on the screen to perform the measurement Results display The measurement results LC LS LL for the distance between circle A and circle B are displayed on the screen 5 Comm 4 A B PPO oO TIP The XD and YD measurement results indicating the distance between the two circles along the X and Y axes vary depending on the position and orientation of the model workpiece on the XY table In order to obtain measurement results that match the dimensions shown in the section titled Model Workpiece before starting the measurement perform the operation described in Section 3 2 Aligning Part Coordinate System Using Edges as Reference 2 8 No 99MBA038A Aligning Part Coordinate System This chapter presents practice on the procedures for aligning the part coordinate system using the model workpiece 3 1 Aligning Part Coordinate System When the data processing unit is turned on the coo
13. he screen to perform the measurement Inputting tolerance data Output Item Nominal U Tol Move the cursor to the input columns and enter the Coord x 6 000 0 010 nominal values and tolerance values using the numeric keys Note that items with no input data are ia p not judged Completion of inputting the tolerance data Press the F5 function key corresponding to Results display The measurement results for circle A are displayed on the screen lt Remarks gt If the deviation exceeds the tolerance zone NG or NG is displayed as GO NG judgment result 4 1 0 No 99MBA038A Al Measurement This chapter presents practice for measurements utilizing artificial intelligence Al using the model workpiece 5 1 Al Measurement Function The Al measurement Artificial Intelligence measurement is a function of automatically recognizing the type of the measured basic feature such as a circle a straight line etc from measured points data The following types of basic feature can be automatically recognized by the system using the Al function Table 5 1 1 Applicable number of Type of feature Remarks measurement points Circle Ellipse Rectangular hole TIP See Chapter 4 of the Software Guide for further details on the Al function No 99MBA038A 5 1 5 2 Performing Al Measurement Purpose of Practice To practice measurements utiliz
14. ined from the origin which serves as a reference NOTE When measuring circle A and circle B note the order in which the measurements are performed as the direction of the coordinate system s reference axis varies depending on the measurement order Y A B aX B a wa 2 1 The X axis direction orients from the center of the first measured circle to the center of the second measured circle TIP After this measurement example the coordinate data input style remains Circle center input Use the following procedure to reset the coordinate data input style to Actual point input Table 3 3 2 No Operation ___Screen display and remarks Selecting the coordinate data input style Press Ea Then from the icon menu press the numeric key corresponding to TIP See Chapter 5 of the Software Guide for further details about the coordinate system alignment functions e See Chapter 4 of the Software Guide for further details about the coordinate data input style 3 6 No 99MBA038A Applied Measurements This chapter presents practice on applied measurement procedures using the model workpiece 4 1 Multi point Measurement Purpose of Practice To practice taking measurements using multiple points In this section a line is measured at three or more points to determine the angle formed by the line and the X axis and the straightness of the line A
15. ing Distance Between Two Circles cccccesseecesesseeeeeeeeeeeseseseeeeesesneesesesneeeesesseeeeneesnaees 2 7 3 Aligning Part Coordinate System cccccesseecseseeeeeeeseeeeeeeeeneeseseeneesesesneeseseseeeesesesneesesesneeseseseaeseseeanens 3 1 3 1 Aligning Part Coordinate System sssussssnseseunnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nenne 3 1 3 2 Aligning Part Coordinate System Using Edges as Reference cceccssseeeeessseeeseessneeeeseeeenens 3 2 3 3 Aligning Part Coordinate System Using Circle Centers as Reference cceeeccseseereeeeeeenens 3 4 A Applied Measurement iisi raain iaaii nanaii tens cntenesenensed sncedee Ute ecuednaneee tt eneeaa ia 4 1 4 1 Mullti point Measurement cecceceseseeeeeeeeeeeeeeeeeeeseeeeeeeseeseeneeseseseeeseseseeeseeesneeeeseseeeseesseensenennens 4 1 4 2 Selecting and Outputting Required Measurement Items Onlly ccccccseseeeeseeeeeeeeeseeneneeseeeees 4 4 4 3 Recalling Measured Features to Construct a New Feature cccccessecceseseeeceseeneeeeeeeseeeeneeseenees 4 6 4 4 Performing Tolerance JUdQMENE cccceseeececeeseeeeeeeeeeeeeeesneeseseseeeeeseeneeseseseneesesesneeseseseeseneseanens 4 9 5 Al M aSureme nt i2fi cecil cecreesdecee device aE e Cocca cttvcdetiaecer setters ssteceedevteccssrssttesessluetedeeesrevacecterveeeecds 5 1 5 1 Al Measurement Function cccccceeeeneeeeeeee eee eeeeceeeenseeeeeenseeeeeenseeeeeeaseseeeeease
16. ing the Al function using the model workpiece In this section line A circle B and angle C are measured successively in the Al measurement mode Fig 5 2 1 Operating Procedure Table 5 2 1 Operation Screen display and remarks Preparing the workpiece Set the model workpiece on the XY table as shown below and focus on it OCG L Seer es 2 Aligning the part coordinate system The explanation for the operations from For the aligning procedure see Section 3 2 Aligning step 3 onward assumes that the part Part Coordinate System Using Edges as Reference coordinate system has been aligned 5 2 No 99MBA038A 5 Al Measurement Operation Screen display and remarks 3 Setting the Al measurement function to ON Measuring line A Measure three points on line A 1 lt Remarks gt The icon corresponding to the automatically recognized basic feature type is highlighted Completion of line A measurement After the desired measured points have been entered press the F5 function key corresponding to Results display The measurement results for line A are displayed X gt 0 0933 i F1 0 012 Measuring circle B Measure three points on circle B Q 1 oO lt Remarks gt The icon corresponding to the automatically O a recognized basic feature type is highlighted No 99MBA038A 5 3 N
17. n some cases it may not be possible to display all of the output items at once In such cases scroll through the screen to view the hidden items using the up and down cursor keys Completing output item selection lt Remarks gt Press the F5 function key corresponding to Only the output items with an asterisk next to them will be output after the measurement Measuring edges A and B lt Remarks gt Measure edges A and B Follow the information displayed on the screen B s to perform the measurement A 1 G i The procedure is the same as steps 3 to 4 in 2 Section 2 2 Measuring Angle Between Two O C O C Edges GG CS Result display Only the measurement result for the intersection angle A1 between edge A and edge B is displayed on the screen z Sie TIP The output item selection result made in the above example remains in effect until the power is turned off No 99MBA038A 4 5 4 3 Recalling Measured Features to Construct a New Feature Purpose of Practice This section presents practice on recalling measured features to calculate a new feature In this section the measurement results for two circles A and B are recalled to calculate the midpoint between them Operating Procedures Table 4 3 1 Operation Screen display and remarks Preparing the workpiece Set the model workpiece on the XY table as shown below a
18. nd focus on it Aligning the part coordinate system The explanation for the operations from For the aligning procedure see Section 3 2 Aligning step 3 onward assumes that the part Part Coordinate System Using Edges as Reference coordinate system has been aligned Selecting the circle feature measurement command Press 4 6 No 99MBA038A 4 Applied Measurements Operation Screen display and remarks 4 Measuring circles A and B lt Remarks gt Measure circles A and B using the same procedure Follow the information displayed on the as in step 3 of Section 2 1 Measuring a Circle screen to perform the measurement Results display The measurement results for circles A and B are displayed on the screen O 0 poo P Selecting the point feature measurement command Za Press Displaying the feature construction menu Press the F1 function key corresponding to 2A i Selecting the midpoint construction Press the numeric key corresponding to Selecting the measured features Use the up and down cursor keys N V to highlight the measurement result for circle A and then press the ENTER key Then perform the same operation for the measured circle B No 99MBA038A 4 7 No Operation ___Screen display and remarks 10 Result display The coordinates of the midpoint between circle A and circle B are displayed on
19. o Operation ___Screen display and remarks Completion of circle B measurement After the desired measured points have been entered press the F5 function key corresponding to v Results display The measurement results for circle B are displayed 10 Measuring angle C Measure four points on the two lines forming angle C w O 3 C 1 lt gt ae C C Remarks 11 The icon corresponding to the automatically C recognized basic feature type is highlighted Completion of angle C measurement After the desired measured points have been entered press the F5 function key corresponding to A Results display The measurement results for angle C are displayed TIP If the automatically recognized feature type is not appropriate the feature type can be manually corrected See Chapter 4 of the Software Guide for information on how to correct feature type 5 4 No 99MBA038A
20. rdinate values in the coordinate system matching the moving directions of the XY table are output as measurement results See Fig 3 1 1 Y Gy y 0 0 Fig 3 1 1 Therefore in order to correctly evaluate information such as the center coordinates of a circle on a workpiece as dimensions the coordinate system must be aligned to match the workpiece s position and orientation The aligned coordinate system is called the part coordinate system PCS See Fig 3 1 2 Once the part coordinate system is set it is possible to obtain precise measurements and calculations even if the workpiece s orientation is not adjusted to be parallel with the moving directions of the XY table No 99MBA038A 3 1 3 2 Aligning Part Coordinate System Using Edges as Reference Purpose of Practice To align the part coordinate system based on two edges that are perpendicular to each other using the model workpiece Description of Operation The part coordinate system is set using the coordinate system alignment macro command 1 Fig 3 2 1 Table 3 2 1 Operation No Operation _ _ SScreendisplayandremarks _ Preparing the workpiece Set the model workpiece on the XY table as shown below and focus on it 7 a The coordinate system alignment function menu is displayed Selecting the coordinate system alignment macro command 1 X Press the numeric key corresponding to a Sele
21. seeeenseseeeeeseseeneneesenes 5 1 5 2 Performing Al Measurement cccesesceeeseeeneeeeeeeneeeeseeneeenseceeeenseeeeeeaaeceeeeeaaeeeeeensseeeeseesseeensesenen 5 2 SERVICE NETWORK No 99MBA038A IM MEMO iv No 99MBA038A Before Starting Measurements This chapter presents practice on the preparations which precede measurements using this data processing unit 1 1 Outline of Data Processing Unit 1 1 1 Appearance Display portion LCD Power switch OO ODO OU0 EEO 00O OLO Joco Key panel Fig 1 1 1 No 99MBA038A 1 1 2 Key Panel Layout Basic feature measurement Al measurement key command keys Function keys Screen switching key Coordinate data input style key Coordinate system alignment menu key Measurement macro command keys LOAD key __ CANCEL key ENTER key N Counter function key User defined menu keys Manual print key Numeric keys Cursor keys Fig 1 1 2 Table 1 1 1 No 1 Key ction OS PASIE teas MASURIEN Used to measure and calculate basic geometric shapes command keys
22. the alphabet in their upper left corner such as O4 are used to enter an alphabetic text such as a file name and a comment Screen switching key User defined menu keys 1 1 3 Elements of LCD Screen Main display area Status display area F1 e F2 Egea F3 xy F4 F5 p Function keys icon display area Fig 1 1 3 Main display area Displays counter values measurement results operation guidance etc Status display area Displays information on the currently set functions Function keys icon display area Displays icons for the functions that can be used with a command which is being executed No 99MBA038A 1 3 1 1 4 Measurement Screen lt Measurement standby screen example of circle measurement gt Measurement result window Navigation window Counter Fig 1 1 4 F1 Recalls the measured features and performs calculations etc F2 Recalls the measured features to adopt the representative point coordinates of those features as measured points for the current measurement F3 Changes the measurement conditions Output Items Auto MeasuringCompletion F4 Enables disables input of measured points based on edge detection if OPTOEYE is mounted F5 Completes the input operation of measurement points and outputs results at the multi point measurement In the navigation window the next location to be measured flashes to navigate the next measuring position The flashing location moves
23. the screen 4 8 No 99MBA038A 4 Applied Measurements 4 4 Performing Tolerance Judgment Purpose of Practice To compare measurement results with nominal values and tolerance zones and to make a GO NG judgment In this section circle A is measured and the tolerance judgment is performed D O O ARR Fig 4 4 1 Operating Procedures Table 4 4 1 Operation Screen display and remarks Preparing the workpiece Set the model workpiece on the XY table as shown below and focus on it O oOo C Ey EO Aligning the part coordinate system The explanation for the operations from For the aligning procedure see Section 3 2 Aligning step 3 onward assumes that the part Part Coordinate System Using Edges as Reference coordinate system has been aligned Selecting Menu 2 Press No 99MBA038A 4 9 Operation Screen display and remarks 4 Selecting the command for setting the tolerance judgment function to ON or OFF Press the numeric key corresponding to 2002 Setting the tolerance judgment function to ON lt Remarks gt Confirm that Tolerance Judgment is set to ON The status display changes as follows and then press the F5 function key corresponding kon P 00 to v OFF ON Measurement function selection Press Q Measuring circle A lt Remarks gt Measure circle A at three points Follow the information displayed on t
24. ure Table 2 3 1 Operation Screen display and remarks Preparing the workpiece Set the model workpiece on the XY table as shown below and focus on it O oOo C OOO Measurement function selection Press f t Measuring side A lt Remarks gt Measure side A at two points Follow the information displayed on the screen to perform the measurement No 99MBA038A 2 5 No Operation ___Screen display and remarks 4 Measuring side B lt Remarks gt Measure side B at one point Follow the information displayed on the screen to perform the measurement screen NOTE When measuring a width be sure to enter two points for the edge being measured first and then enter one remaining point for the edge being measured second TIP If an incorrect position was measured it is possible to cancel the measured point data by pressing the CANCEL key prior to entering the last measurement point If the CANCEL key is held down the system returns to the standby state for the first measurement point e The last measurement point cannot be canceled If the last measurement point is not correct redo the measurement No 99MBA038A 2 Basic Measurements 2 4 Measuring Distance Between Two Circles Purpose of Practice To measure two circles to obtain the distance between them Fig 2 4 1 Operating Procedure Table 2 4 1 Operation Screen display and remarks Preparin
25. y corresponding to Selecting ON for printer Use the left and right cursor keys to select All Results w o Command Names for Contents to Be Printed Finishing printer setting lt Remarks gt Press the F5 function key corresponding to Measurement results subsequent to this x setting are printed by the printer TIP To cancel printer output select None in step 3 above 1 6 No 99MBA038A Basic Measurements This chapter presents practice for basic measurement procedures using the model workpiece 2 1 Measuring a Circle Purpose of Practice To measure a circle using the model workpiece Q DA Fig 2 1 1 Operating Procedure Table 2 1 1 Operation No Operation __Screendisplay and remarks____ Preparing the workpiece Set the model workpiece on the XY table as shown below and focus on it 2 Measurement function selection No 99MBA038A Operation Screen display and remarks 3 Measuring circle A lt Remarks gt At any three points on the circumference of circle A Follow the information displayed on the center the projection screen crosshairs and then press the screen to perform the measurement LOAD key Results display The circle A measurement results are displayed on the screen 4 018 lt Diameter 4 _ Ke NOTE The three points that are measured should be spaced as far apart from each oth
Download Pdf Manuals