Home

Jiva TP - 5815 Pro/ - 8015 / TP – 5815N Pro

image

Contents

1. POSIFLEX Jiva TP 5815 Pro 8015 TP 5815N Pro 8015N Series Touch Terminal User s Manual FCC Notes PUC This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual may cause interference to radio communications It has been tested and found to comply with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures to correct the interference Warranty Limits Warranty terminates automatically when any person other than the authorized technicians opens the machine The user should consult his her dealer for the problem happened Warranty voids if the user does not follow the instructions in application of this merchandise The manufacturer is by no means responsible for any damage or hazard caused by improper application About This Manual Posiflex has made every effort for the accuracy of the content in this manual However Posiflex will assume no liability for any technical inaccuracies or editorial or other errors or omissions contained herein nor for direct indirect incidental consequential or otherwise damages including without l
2. The power switch is safely located in recessed side and it can be defined as a ON switch only through software command Preconditioned power up function by alarm clock or COM port MODEM ring or LAN Se ON ON Optional Items Note The underlined items in the following list means that option must be a b c d e set prior to shipment from the factory The rest items can be set by the dealers DDR2 SDRAM memory expansion up to 1GB for TP 5815 Pro TP 5815N Pro or DDR SDRAM up to 2GB for TP 8015 TP 8015N RS232 interface Infra Red type touch panel durable for 50 million touches min at same spot Integrated side mount upgrade kit among KP 100 SD 100 SD 200 BC 100U Integrated rear top mount 2 by 20 LCD customer display PD 302 Integrated base mount device choice among PD2501 or PD2602 VED pole display or LM 6201 12 1 or LM 6501 15 2 LCD monitor Part 6 USB interface external slim type CD ROM drive or COMBO drive Internal slim type CD ROM or COMBO drive in universal base models UPS battery in base Preload OS 2 in 1 cash drawer control cable CCBLA 238 Interface select for resistive touch panel among PS2 for TP 8015N only RS232 and USB Wall mount kit WB 6000VB WB 6300 WB 6600 WB 6800 Major Model Numbers Jiva TP 5815 Pro C7 1 5 G CPU slim base or universal base with 1024 x 768 LCD panel of 262 144 colors Jiva TP 5815N Pro C7 1 5 G CPU slim
3. A larger external battery may be connected to give an extended operation Please check your dealer about this capability when required WARNING If there are any signs of over charging or leakage of electrolyte please contact your dealer immediately Part 16 Power Supply The operating voltage range of the power adaptor should cover the local power supply for proper operation The power cable the power outlet and any power fusing arrangements must conform to local safety regulations Please never do any connection disconnection when system is still powered on Please always keep the external power adaptor in a free air circulation POWER ON OFF There must always be at least 10 seconds waiting before switching on again once the system is powered off successfully Power Status LED Indicator There is an LED under the printed logo that serves for several purposes The relationship between LED status and other conditions is summarized in following table LED Status System Status lExternal Power UPS Battery Powering Up Off Off Off Not present Not possible Off Off Off Present Not allowed Green Off On No influence Allowed Blue On On No influence Not required Blue flash On Off Activated Not required Green rapid On Off Running at Net iatied flash low capacity Hardware Power Switch The power switch is at left side of the main unit This switch turns the system on when slid downward
4. Connect this End to Main Unit Now turn the adjustable stand assembly back to normal orientation and arrange all cables to come out of the area for mounting main unit from the bottom edge for ease of later operation PREPARING THE MAIN UNIT On the back of the main unit there is a service window among the 4 matching pegs Remove the service window lock screw to find several jumpers The jumpers in this window are designated for VGA port and COM port power supply function Please consult your dealer for technical support on setup of these jumpers Please note that only those qualified technicians may adjust in the service window with information from Posiflex and the contents in the service window may change without notice as time develops Jumpers RTC Battery CAUTION Risk Of Explosion If Battery Is Replaced By An Incorrect Type Dispose Of Used Batteries According To Local Regulations SIDE amp REAR TOP MOUNT UPGRADE KIT Please follow the instructions in the manuals delivered with the side mount upgrade kit KP100 SD100 SD200 or BC100 and the rear top mount upgrade kit PD302 to fit them in Jiva system construction Service Window Part 13 E DESKTOP MOUNTING Matching Holes Round Part Slot Part Matching Pegs Removal Hollow Match the matching pegs on the back of the main unit against the matching holes on the stand assembly First aim the matching pegs toward the upper round part of th
5. VGA port in the Jiva system supports Posiflex stand alone touch or LCD monitors like TM 4115 LM 6212 or TM 7112 if there is no base mount 2 LCD display This port supports extended mode dual display function in WinXP To support the DC power to these Posiflex monitor use Part 18 the DC adaptor for TM 4115 TM 7112 Connect the adaptor to VGA cable or use Posiflex VGA power cable and set an internal jumper in the main unit to supply the required power through the VGA connector for LM 6212 Do not connect other monitor to this port before the power in this port is disabled CUSTOMER DISPLAY Please follow the instructions on the manual that comes along with the customer display PD 2501 or PD 2602 when it is installed SERIAL PORTS The serial ports in Jiva system can supply a 5 V DC through pin 9 after proper jumper setting change However they are set to standard RS232 serial ports as status at delivery COMI serial port must always be occupied by a suitable serial device or COMI terminator as supplied If this port is left vacant or connected with something like a mouse the cash drawer control and the power management function may fail to work correctly For serial Modem application please use COM3 4 port to minimize any hardware resource conflict For TP 5815N Pro using RS232 interface touch control such as the Infra Red type touch the COM2 port is occupied and covered Please never try to open the cover Otherwise the product w
6. base or universal base with 1024 x 768 LCD panel of 16 2 M colors Jiva TP 8015 Celeron 2 0 G CPU slim base or universal base with 1024 x 768 LCD panel of 262 144 colors Jiva TP 8015N Celeron 2 0 G CPU slim base or universal base with 1024 x 768 LCD panel of 16 2 M colors Jiva TP 8015I Celeron 2 0 G CPU slim base or universal base with 1024 x 768 LCD panel of 262 144 colors with Infra Red type RS232 interface touch screen Jiva TP 8015NI Celeron 2 0 G CPU slim base or universal base with 1024 x 768 LCD panel of 16 2 M colors with Infra Red type RS232 interface touch screen Part 7 INSTALLATION GUIDES CAUTION Before any installation or cable connection to the set please always make certain that the system is turned off and the external power source to the set is removed to prevent electric hazard Never touch any metal pin in the connectors or circuits to avoid high voltage hazard or electrostatic discharge damage unless the operator is well grounded Failure to do the above will void the product warranty OPENING CABLE COVER Please follow steps A to C sequentially with reference to pictures below to remove the cable cover for both slim and universal base models h 2 4 D Step A Push lock release lever back Step B Turn panel to most horizontal position J Step C Use plastic latch key turn fully counterclockwise FA then remove at both sides to release cable cover
7. Step D Pull at the removal hollow toward the user DISCONNECTING ALL CABLES After removal of the cable cover the connector area will be accessible then Please first note orientations of every existing cable connection and then disconnect every cable properly before separating the main unit from the adjustable stand assembly Please note that the click lock spring has to be pressed down prior to pulling out the connector such as the LAN port or the CR port Please also note that the fixing screws have to be loosened free prior to disconnection such as the VGA port or the COM ports or the LPT port Please always hold the connector head instead of pulling on the cable wire when disconnecting any connector Failure to do this could damage the cable and jack that is considered as an artificial destruction Damages due to incorrect disconnection operation are not covered by product warranty Part 8 SEPARATING MAIN UNIT In order to settle the touch terminal properly in a point of service system all the cable connections have to be routed through its base either slim or universal Therefore please observe the procedures from A to C below to separate the main unit from both slim and universal base stand assembly after all cables in cable cover disconnected mE Step A Prepare a soft clean flat surface such B as a piece of cloth on the desk to seat A the front surface of main unit x Step B Press the Lock Release button and Ex me
8. antime aB A Step C Slide the base stand assembly to left to VA separate OPENING STAND ASSEMBLY Take the adjustable stand assembly and turn it up side down to show o B ttom Plateo the bottom of the base e Fixing Sole i Remove the bottom plate fixing screw and push the bottom plate to the right as in these two example pictures at both sides to open _ Bottom Plate Fixing Screw Push Bottom Plate This Way To Ope Auxiliary Cable Exito Push Bottom Plate This Way ToO e o Open e Take the bottom plate up and the inside of an example slim base model looks like this in the left picture The inside of an Slim base bottom Universal base bottom example universal base model TP 8015N differs from the example on power adaptor Inside universal base Inside slim base Part 9 portion will look like the right picture Both with numbered items listed as below However there could be some variation to the contents inside depending on what option items actually installed When the HDD installed is the 2 5 type the HDD mounting bracket and the bottom plate will also look different 1 Cable Exit For External Connections 2 Cable tie 3 CD ROM Bracket For Universal Base 4 Cable Passage To Main Unit For Desktop Mount Application 5 HDD Bracket 6 HDD Bracket Fixing Screw 7 Power Adaptor In Universal Base 8 Power Adaptor Bracket Fixing Screws 9 UPS Battery Brack
9. arranty is voided SOUND PORTS The audio port in Jiva system supports a Microphone in and a stereo line out jacks There is a single channel internal audio amplifier in the output port to drive the 2 slim type speakers installed in the I O area inside cable cover with 1 VV audio power For TP 5815N Pro this item is an option Should the application demand for higher audio power please first ask your dealer to disable the internal audio amplifier and connect the amplifier or a pair of speakers with booster to this port Please note that this modification should be handled by a qualified technical person only FAN CONTROL In the preloaded OS for Jiva system there is an embedded function that keeps monitoring the interior temperature and the fan revolution rate and regulating each required fan power to obtain maximum ventilation effect with lowest possible noise Please find it in Posiflex Tools of Program Files It will remain enabled even after system turning off on until being disabled On occasion of unexpected system failures please check the airflow condition and environment temperature of the system Check if the fan is stuck by something like dry grease or threads Try to correct the situation when the system is off and cooled down You may power up the system again after the Part 19 system cooled down and trouble cause removed However if the failure repeats please consult your dealer for possibly fan replacement on wor
10. d in the left picture with the four matching holes in the wall mount brackets as also marked in circles in the top pictures and allow the main unit to slide down the winding grooves in the wall Part 11 mount backpack Connect all cables coming out of the backpack into the cable cover area of main unit The area required for wall mount application is determined by the main unit dimensions and is 375 mm in width and 315 mm in height BASE MOUNT UPGRADE KIT On rear edge of the stand assembly for desktop mount application there is a rear connect cover Either a 2nd LCD display panel option LM 6201 or LM 6301 or a customer display option PD lt 2501 or PD 2602 can be installed here after removing this cover Please note that there could be certain restrictions to the tilt angle range for the main unit when the base mount upgrade kit is mounted Investigation for the acceptability of such kind of restrictions must be taken before decision to install a base mount upgrade kit 12 2 LCD Panel Or Customer Display To remove the rear connect cover in slim base please refer to the inside view of the base unit after removal of UPS battery as in picture at right and use a flat head screwdriver to pick the plastic hook plate of the rear connect cover from inside The rear connect cover of universal base can be removed by pushing the plastic hook plate of it from inside as marked by white arrow in the right picture Howev
11. dity non condensing max wet bulb 26 C UPS Battery option General care The UPS battery is consumables beyond product warranty Please definitely observe the alerts in beginning of this manual Please always disconnect the battery if the system is to be powered off for more than few days Reconnect it and turn on the system to recharge the battery for 1 2 hours every 3 months every month for temperature lower than over 30 C Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smooth operation during intermittent or few minutes up to 30 min for TP 5815N Pro or 2 6 min for TP 8015N power failure Battery replacement In the preloaded OS for a Jiva system there is a built in utility Power Manager that will interface the UPS battery monitor status with user When a health warning popup message appears please immediately replace the used up UPS battery at power off if the battery is actually connected there but found inoperable by such messages Emergency treatment The battery is constructed maintenance free and leakproof However should any accident happen and the sulfuric acid from the battery spills on skin or clothing wash immediately with water If the acid comes in contact with eyes rinse eyes with large amount of clean water and see a doctor immediately
12. e hole and make sure that all pegs are inside the holes Then slide the main unit down to move the pegs into the lower slot part of the holes till it clicks Note that all the cables come out of the stand from the lower edge and won t get trapped by this mounting operation If later on you want to remove the main unit from the stand you ll have to press down the lock release button on back of the stand at the time lifting the main unit For desk top counter mount application the adjustable stand assembly requires a base of 268 mm wide and 282 mm deep However the main unit itself is 375 mm wide and can take maximum total height of 373 mm for slim base models and 400 mm for universal base models if no upgrade kit installed CONNECTING CABLES To re assemble the main unit with stand assembly for operation please connect all required cables to the appropriate connectors Please make sure that each connector is connected to the correct port with the correct orientation Damages due to incorrect connection or orientation are not covered by product warranty Some connectors like the LAN connector have to be gently inserted until a click is heard It is recommended that connectors such as the external VGA LPT and COM connector be screwed into place once seated If the COMI port must be used the COM1 terminator that occupies the COM1 port must be removed and safely preserved for future use However when using the COMI port it is advisable to use de
13. e wall of base box from the right as arrowed in above left picture then apply the fixing screw Please pay particular attention to the environment requirements for UPS battery in next chapter USING THE TOUCH POS WALL MOUNTING WB 6000VB VVB 6300 VVB 6600 VVB 6800 Select a flat surface on vvall of adequate strength and with proper ventilation and space condition Please use the right material to hold this terminal according to the wall material Drywall concrete solid wood etc Consult with your Back side of contractor if it is necessary A fully equipped system may WB 6000VB weigh up to 11 kg or 23 lbs Please fix WB 6000VB at the holes inside the guide holes circled in the picture to the wall or fix it to a VESA joint at bosses on back side For WB 6300 WB 6600 and WB 6800 please separate the back cover of the wall mount pmm bracket kit and fix it to wall at the 3 or 4 arrowed holes as appropriate according to these pictures at right per type of back covers with proper materials and proper preparations Install required optional device kits with their mechanical fixation parts in the wall mount bracket and hang the backpack to the back cover that is already fixed on wall with the cables coming out of the brackets through the openings marked with rectangles in the top row pictures above Screw lock the top side of the backpack Align the four matching pegs on the back of the main unit as circle
14. er this picture is a top side down inside view of the stand assembly with base box removed for illustration purpose only Please push the plastic hook plate with finger through the top opening in the stand assembly to remove the rear connect cover Fit the joint base of PD 2501 or PD 2602 or PD 305 or LM 6201 to the rear connect cover opening Then make the cable go through the normal cable exit under the joint base as in these pictures Fit 2 screws with d washers to hold the joint tight For low profile customer display PD 305 the installation procedure is same Remember to enable the 5 V DC supply in the COM port of the main unit for PD 2501 PD 2602 or PD 305 or the 12 V DC in VGA port for LM 6201 Part 12 15 2 LCD Panel Please follow the installation instruction that come alone with the 15 2 LCD monitor LM 6501 to mount the interface bracket kit onto the LCD panel Fit the interface bracket the same way as joint base of LM 6201 to the rear connect opening and fix with 2 screws with washers Route the VGA through the cable exit of the base stand to the main unit Connect the attached power adaptor for its power source ROUTING THE CABLES Place all the cables required for connections to the main unit except those for the integrated attachment through the front part inside the stand assembly Be sure not to damage any cable during this operation Route Cables through Front Part
15. et For Universal Base 10 UPS Battery Bracket Fixing Screw For Universal Base 11 UPS Battery 12 Velcro Strap For Slim Base 13 2 Cable Exit For Slim Base CABLE PASSAGE Please route all cables through the cable passage to main unit in desktop mount application Hold the cables together with the cable tie Pass all cables for external connections excl those for HDD and UPS battery through the cable exit For slim base models in desktop mount application when cable connection through a hole on desktop underneath the system is required please slide open the auxiliary cable exit on bottom plate and route all external connections through this auxiliary exit Then fix back the bottom plate if there is no option unit to install INSTALLING UPS BATTERY The optional UPS battery is delivered in the carton if it is ordered For slim base model please place the UPS battery in the direction shown in the right picture and use the Velcro strap through the 2 standing slits on F base box to fix the battery in position firmly Route the battery connection cable through l appropriate passage to the battery Slim base w connector on the main unit HDD removed Please remove the UPS battery bracket fixing screw and slide right the UPS battery bracket to take it out for universal base model Part 10 as in left picture Put the battery in at the other end first and remount the bracket with its tongue matching under a bridge in th
16. he battery as soon as the monitoring software indicates the battery is out of service Attempt to recharge a dead battery is dangerous lt A separate battery monitor is not required for this series DAILY MAINTENANCE GUIDE For regular cleaning of the Jiva systems please use only soft haired brush or dry soft cloth You may use moist soft cloth to remove stains when necessary Apply only proper amount of mild neutral detergent for obstinate stains Please note that never use Acryl dissolving solvent or Polycarbonate dissolving solvent You may apply ammonia based glass cleaner only on the screen surface CAUTION Risk Of Explosion If Battery Is Replaced By An Incorrect Type Dispose Of Used Batteries According To Local Regulations Part 2 INTRODUCTION PRODUCT PICTURES Front Views Slim Base Models 2 8 8 l 9 10 gt db 10 7 Slim Base Models Universal Base nice es Side Views lt 11 Es m 10 ET Slim Base Models 1 12 r 13 1 Slim Base Models Universal Base Models Part 3 Rear Views 1 a ear a II 1 7 12 5 a 14 14 oy 16 Slim Base Models 16 Bottom Views 21 19 17 19 19 20 21 20 26 Slim Base 2 5 HDD Universal Base 2 5 HDD PARTS IDENTIFICATION 1 Main unit 2 Touch panel LCD panel 3 Optional side mount kit 4 Power status indicator 5 Universal base stand 6 Optional CDROM drive 7 Slim base stand 8 Cable cover 9 Re
17. imitation loss of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technologies Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware concerns for general user and is subject to change without notice Posiflex reserves the right to alter product designs layouts or drivers without notification The system integrator shall provide applicative notices and arrangement for special options utilizing this product The user may find the most up to date information of the hardware from web sites http www posiflex com or http www posiflex com tw or http www posiflexusa com All data should be backed up prior to the installation of any drive unit or storage peripheral Posiflex will not be responsible for any loss of data resulting from the use disuse or misuse of this or any other Posiflex product All rights are strictly reserved No part of this documentation may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying or otherwise without prior express written consent from Posiflex Technologies Inc the publisher of this documentation Copyright Posiflex Technologies I
18. mer may take reference from the Jiva technical manual to apply such features Automatic Power On Control The system may also turn on according to some preset conditions such as Modem Ring Up or Alarm Clock Wake Up or LAN Wake Up To utilize Modem Ring Up or Alarm Clock Wake Up function please enter the CMOS setup Power Management Setup PM Wake Up Events and enable the Ring Power Up Control or Power Up by Alarm Save the configuration and exit the CMOS setup program For LAN wakeup an operating caller system connected through LAN to the system is required It also requires a qualified networking technician to check the LAN chip ID of the system for the caller system to wake up When the Jiva system is turned off after a successful boot up the preset automatic power on functions will turn on the system when the preset conditions are met But if the Jiva system is improperly turned off before a complete boot up procedure the above preset power on control functions will be disabled until next turning off after a complete boot up DISPLAY ISSUES Main LCD Display For best viewing result please set your display resolution at 1024 x 768 with true color 262 144 colors for models coded without N and 16 2 M colors for models coded with N In configuration of system memory max 64 MB can be shared for TP 5815 Pro and TP 5815N Pro max 128 MB for TP 8015 TP 8015N and TP 8015NI as the video memory VGA Port The
19. moval hollow in cable cover 10 Lock release lever for tilt angle adjust Part 4 a b c e f Sze 11 Optional rear top mount kit PD 302 12 Lock release button for main unit detach 13 Power switch 14 Rear connect cover 15 Power connector hole 16 Cable exit 17 2 cable exit 18 Auxiliary cable exit 19 Rubber feet 20 Bottom plate 21 Bottom plate fixing screw 22 2 5 HDD window 23 Steel wire handle 24 Rubber handle seat 25 2 5 HDD bracket fixing screw 26 2 5 HDD bracket cover PRODUCT FEATURES Standard Features CPU C7 1 5 GHz for TP 5815 Pro TP 5815N Pro Celeron 2 0 GHz for TP 8015 TP 8015N An advanced slim or universal base design The slim base models TP 5815N Pro 8015N support 2 LCD display or pole mount customer display storage room for HDD and optional UPS battery in desktop mount application The universal base models support extensive features as 2 LCD display or pole mount customer display storage room for power adaptor HDD optional internal CD ROM drive and optional UPS battery in desktop mount application Also possible to be without base but with wall mount bracket for wall mount application Support Win 2000 Win XP Pro WEPOS and Linux environment High quality 15 TFT active matrix LCD panel Vertical type LCD panel with easy tilt angle adjustment from 15 to 70 Durable resistive type leading edge Infra Red type optional touch panel
20. n out TOUCH PANEL All paragraphs below are applicable for models with touch panel only The user of those models without touch panel can ignore them and consider this user s manual ends here Mouse Emulation The touch panel in Jiva system uses USB interface as standard Only the optional InfraRed type touch panel uses RS232 interface When the touch driver is properly installed this touch panel works exactly like a standard mouse except when the system is running under safe mode The mouse emulation functions include left button click click drag and drop left button double click right button click The only deviations are the system can give a beep or not to beep on each touch a right click sticky button is provided for the effect like clicking on the right button of a mouse Posiflex USB Touch Manager A program named Posiflex USB Touch Manager and a right click sticky button tool in the program group Posiflex USB Touch Tools is installed in the preloaded Windows system with a USB interface touch panel controller This program can also be obtained by download from the POSIFLEX web site RS232 Touch Controller If the Jiva system purchased is the leading edge Infra Red type touch models the touch controller is of RS232 interface The Posiflex Touch Terminal Manager above should be disregarded In these models the COM2 port of the TP 5815N Pro or TP 5815 Pro will be covered in the connection area Removal of
21. nc 2009 All brand and product names and trademarks are the property of their respective holders P N 16320900040 Part 1 ALERT TO OUR HONORABLE CUSTOMERS Please always read thoroughly all the instructions and documents delivered with the product before you do anything about it Don t take any premature action before you have a full understanding of the consequences e This product contains inside a Lithium battery and maybe also a sealed type Lead acid battery if the UPS battery option is ordered Please always follow local environmental protection laws regulations for disposal of used batteries and always replace only with battery of same type Ifyou have an UPS battery installed in the product lt Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work Do not power off the system just by shutting off the AC power leaving the battery supporting the whole system till completely exhausted Repeatedly using it up or improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected lt Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you are going to re power on the system Replace t
22. only when external power is present The switch will always spring back to its original position when pressure is removed This button turns the system off when slid downward again during power on status However if the system hangs due to any reason such as software resource conflict you may have to utilize the forced power off feature by pressing the switch downward and holding for within 10 seconds In case this forced power off fails please disconnect the UPS battery if installed and the AC power supply for few minutes then reconnect them This switch can also be programmed as an ON only switch by the application program so that this switch will always turn the system on when activated but will not power off the system when depressed again the forced power off feature will not work in this mode When using this feature please Part 17 make sure that the software application has the ability to power off the machine In preloaded Windows Posiflex Power Switch Manager in Posiflex Tools in the Program Files helps managing these functions Software Support Features The Jiva series provides a software power off for application program maneuvers as mentioned above The Jiva also provides a specific means for the software to detect if the system is working on external or UPS battery power So the compatible software applications have the ability to change operating conditions when running on standard backup power The software program
23. se use the recovery CD or DVD in rescue operation only Using it otherwise may wipe out whatever stored in the HDD All upgrade devices drivers needed for manual installation in usual way are available in the subfolder drivers in OS recovered HDD and the latest versions of these required drivers will be available on our web http www posiflex com tw Then follow instructions from your system integrator for software recovery OPERATING SYSTEM INSTALLATION This product is a highly professionalized equipment The installation of an OS into a machine without any preloaded OS could constitute major difficulty for average user or obstacle by possibly unintentional negligence even for PC veterans to accomplish such a task Therefore OS installation into a system without preloaded OS is highly discouraged Posiflex shall not be responsible for any technical support to questions arisen due to non preloaded OS Part 15 USING THE TOUCH TERMINAL APPLICATION ENVIRONMENT It is very important to check the following operational guidelines Ventilation This terminal must NOT be used in an environment with restricted ventilation There must be at least 25 mm air clearance around any ventilation holes with a free flow of air around the unit at ALL times for the installation Operating Environment The equipment must not be operated or stored in extremes of both temperature and humidity moisture Operating range 5 C to 40 C and up to 80 humi
24. that endures 35 million touches min at same spot Spill proof water resistant structure allowing easy cleaning Easy maintenance construction Various I O ports supported including 1 one PS 2 KB port 2 one PS 2 mouse port 3 4 serial ports All with capability for 5V DC support Part 5 o p r one parallel port 5 USB ports for TP 5815N Pro and 6 USB ports for TP 8015N one LAN port 10 100 base T Ethernet upgradeable to 1 Gbps one external VGA monitor port one IDE connector and HDD power connector for HDD in base 9 one 4 pin lock type DC 12 V power input connector 10 one UPS battery connector 11 one CR port for control over 2 cash drawers max 12 audio ports 1 Microphone input and 2 optional slim type speakers Touch control functions left right button double click drag amp draw Dual display support per OS capability VGA memory size shared from system memory 16 64 MB for TP 5815N Pro 16 128 MB for TP 8015N Support high performance DDR2 DRAM in two modules with maximum memory size 1GB for TP 5815N Pro 2GB DDR DRAM in two modules for TP 8015N Integrated structure for side mount upgrade kits KP 100 SD 100 SD 200 or BC 100U and optional top mount customer display PD 302 The MSR in side mount kit is with software programmable parameters for Win 2000 or Win XP pro Built in UPS function to support the system from intermittent power failure battery itself is an option Accidental power off protection
25. this cover will void the product warranty Once the RS232 touch controller driver is installed the user can utilize it to control the mouse emulation Please click Start Settings Control Panel and Elo Touchscreen or just click the elo icon in tool tray to engage this utility However with this touch controller driver certain display mode like full screen display of Windows DOS box should be avoided Posiflex Touch Terminal Manager A program named Posiflex Touch Terminal Manager and a right click sticky button tool in the program group Posiflex Tools is installed in the preloaded Windows system with a PS 2 interface touch eoemeee G panel controller in TP 8015N This program can also be obtained by download from the POSIFLEX web site
26. vices that provide proper hardware handshaking signals in order to keep other embedded system features A serial mouse is one example of a device that does not support handshaking Please note that conversion cables are used for connecting RS232 devices to COM3 4 port of TP 5815N Pro Adjust the slack of each cable and close the cable cover Re adjust the tilt angle of the screen for best viewing Connect the cables to appropriate external devices through the cable Part 14 exit at the bottom of stand assembly Please make sure that each connector has to be connected to the right device in the right way CAUTION On doing any insertion or extraction of any connector please always hold the connector head itself instead of pulling on the cable wire Failure to do this could damage the cable and jack that is considered as an artificial destruction and is not covered by the warranty OPERATING SYSTEM RECOVERY For Jiva systems preloaded with Windows XP Pro or WEPOS on HDD Posiflex provides recovery CD or DVD delivered with the touch terminal for the preloaded operating system The System Integrator shall take care of software restoration after OS recovered A Posiflex supplied USB interface CDROM or COMBO drive or the internal type IDE interface CDROM or COMBO drive for the universal base models will be required for such action Other brand CDROM drive may require its specific driver different from what supported in the recovery CD or DVD Plea

Download Pdf Manuals

image

Related Search

Related Contents

INSTRUCCIONES DE USO  Notice du Bio-butteur  Yamaha Protatone PSR-6700 User's Manual  Ajuda do Programador Kurumim  User guide  0570-088988  n - Union de Quartier Mutualité  取扱説明書GTRL  SMC ADSL Barricade™ g SMC7804WBRAEU  R.O.GNT 0605.28  

Copyright © All rights reserved.