        Installation & User Manual V2.04
         Contents
1.     Setting the GSD  controller address       Phase 1   Setting up the GSD Controller    Stepes OOOO    a Install the main GSD Controller and power up    Default the controller immediately via the dip switch settings   See instructions on page 11    Important  Once powered up and the controller has completed the default  the process   reset the dip switches to the correct address positions    See instructions on page 11     Connect the PC lead to the Contoller and configure the PC Comms   A  lf using a Serial to USB converter   Follow USB converter instructions   B  Establish the Com Port no     Follow instructions on the CD provided to install the GSD PC application   To download the latest drivers  enter the following link in your web browser  http     www globalsecurity ie  download  GSDW in Access en US zip    Open the application with the PC connected to the controller  Log in to the application as the Engineer  not the administrator  with  the password 6666   Go to the settings tab and set the Com port number for the  Controller as established above     The Controller icon will change colour to show that the Controller is  on ine     Open the    Doors    tab in the main menu to add the required number of new  doors to be part of this network  1 door will already be added by default   Click on the         button to add new doors          to remove doors     M ake sure all doors are    Enabled    and then click Save     Open the Settings Tab and do a Full Download to the 
2.   NO    Inputs 3V Lithium         dl  J    Fire Alarm  Panel NOTE     Common OV from the   Fire Alarm Panel and the OV  from the Controller to   avoid any ground loop issues        Direct Connect   All Dip Switches OFF    W hen the fire alarm  is activated   ie OV  removed from IP3   the local door will be  opened           L  Network Diagrams    12V              RS485 Converter    A a EEECoC T    Controller 1       S 42V 4  E oV  2  Connect using RS232 RS485 g l 38    cable to serial port on PC    Daisy Chain  Set Baud Rate to 19200 ert Paice    PC Network Connections  when using more ON B  than one GSD Controller        Daisy chain the PC network A  B   OV to each controller     Set an individual address for each controller  between 1  amp  3 using the dip switches     see below    Controller 2  U             9  Controller 1 Controller 2 i    19911q Od       Controller 3    Address 1  Set SW 1 ON Address 2  Set SW2 ON Address 3  Set SW 3 ON                Network Diagrams          Direct Connect   All OFF Address 1  Set SW1 ON Address 2  Set SW2 ON    Note  Address 3  Set SW 3 ON only    To restore the factory default setting   Set ALL Dip  Swithces 1 2 3  amp  4 to the ON position and then  power up the GSD Controller     Example  All Dip Swithces are set to the ON position     Note  Factory Default settings will be restored after  powering up the controller with All dip swithces ON  The  dip Switchess should then be set to the controller  address as shown above in section
3.  networks and Door Controls in the same  building on a different network becoming part of this new network     Note  For Wired 485 Door Controls  right click on the Controller on the  right hand side of the application and select    Manually Assign Address     from the drop down menu    Once all new Door Controls are found by the Controller they will all      beep    with the number of the next available address  door position on the  Controller    e g  if door 2 is the next available address then all Door Controls will beep  at the same time with 2 beeps  This is basically saying that any door can  be assigned to this address   it   s up to the installer to decide which one   Also   you will notice that the Key back light of the keypad Door Controls  will be illuminated with the next available address as well    i e  Key 2 will be illuminated for this example     Go to the Door control that you want to make door 2 on the network  system  it should be beeping 2 times   Press any key on this keypad and  the system will automatically assign this door control to door 2 location on  the system  Present a card if the Door Control is Prox Only     Note  All other Door Controls will now start beeping with the next  available address i e     3 beeps    in this instance and so on every time you  enrol a new Door Control  The Key back light will also correspond to  each address as the system fills up        Phase 3   Enrolling Door Controls    Step  Description S La a A    Once all Doo
4. Controller   this  gives the Controller a clean set of instructions before beginning to enrol  doors onto the network  This will take approximately 1 minute     ARNING  A New Network should only be created on first installation   Creating a new network will overwrite any existing network information  and any enrolled Door Controls will be un enrolled  All Door Controls will  have to be defaulted and re enrolled on the new network that has just  been created    A new network is now ready to be created   Go to the    Controllers    tab and Click on the    Create a New Network    button   Click Yes on the    Hit yes if you want to proceed    pop up     Note  The red LED on the Controller PCB will remain ON during the  process  It will take about 20  60 seconds to complete  The red LED will  Start to flash again when the Network is created        Phase 3   Enrolling Door Controls    Step  Description O    E All Door Controls should be installed at this point and powered up     All Door Controls must be defaulted before joining a network   Note  Door Controls will be shipped with their factory default settings   Enter Engineer mode on each Keypad Door Control in the following way  Press X followed by 6666  Enter 55   to default  Press the tick to confirm   the keypad will now go through the  process of defaulting itself   W hen this process has complete hit the X button to leave engineer  mode and to put the keypad control in the    Scan Mode      the Red Led  on the Door Control 
5. Other products from GSD    Stand alone products    global security devices    GSO also offers fully functional standalone door controls for less complex  door management  This attractive design  with modem aesthetics  will  complement any building    65D Digital Keypad  GSO Proximity Switch    OSD Biometric switth      Acess control     Door monitoring     Manager user     fire and intruder alarm interface     Backlighting     Tamper resistant     5 Amp relays     indoor or outdoor use     Robust polycarbonate housing  with stainless steel keys    Multi format      RRO reader eei Installation Instructions ED       PIN ACCeSS f    FngerPrnt T Installation Diagrams ED    ACCESS     IP Rating P67   IP67 IP67 P65   No of doors   controlled   2 door 1 door 1 door 1 door     Mounts onto a standard electrical Be i               back bax Power 12v to 24v   12v to 24v 12   to 2A   12v OC only    re   ee   ee   cee   Wiring Diagrams ED    System Overview  iy       Network Diagrams ED       Operating Instructions Ry    Fingerprint Enrollment FED       global security devices Wi Plus Controller       Technical Specs  GSD Wi Plus Controller    Current consumption with load  max     W 135mm D  46mm H 200mm       Technical Specs   Wi Plus Door Controls    Dimensions   Flush Mount    Features    16  16  16    Doors controlled 10  Us  Reporting Facility Yes    Challenge Facility Yes  Logging Unlimited  Input  Output M apping CCTV  amp  Lift control    Supports Wireless  amp  RS485 Networks  A
6. instead of    All Day  Every day           UserGroups are created by combining pairs of DoorGroups with  Timezones  Each UserGroup can have up to 6 pairs of DoorGroups and  Timezones  Select DoorGroups and Timezones from the drop down menus  to add to the current UserGroup     Timezones are the periods of time for each day of the week that access    will be granted  Select times and tick the days of the week this time is valid     4 time periods can be created for each timezone  Select    Holiday Access     to grant access for holiday periods  Double click on the    Holiday Access    to  add days to the holiday periods  Use the calender to select these days     DoorGroups are created by grouping doors together  e g all the entry and  exit doors could be grouped together as    Peremiter Doors     Select a Door  from the    All availble Doors    window and drag it to the    Doors in Current  Door Group    to add it to the Door Group  Repeat for adding each door     Phase 6   Downloading Configuration     Step  Description O    After all users  access levels and door control settings have been finalised   a full download to the controller should be carried out     Go to the    Settings    tab and click on    Download Configuration     A pop up  window will appear  tracking the status of the download  All settings will be  downloaded to the Controller and Door Controls     Enrolling User FingerPrints  Step Description  W Note  M ake sure the USB Fingerprint reader is attached to 
7. ot store the finger EL UL OA  print  It uses an algorithm to generate a es  binary representation using sample points  from the fingerprint  It uses this information    to then validate each users fingerprint     wy        Py Finger Placement Wi BIO Finger Placement Wi BIO FEJ    Correct Finger Placement Incorrect Finger Placement    Correct  Incorrect    Note  Ensure that the finger is centered and Note  Incorrect placement   finger does not  placed flat to the surface and fully covers the fully cover the sensor window   sensor window  The door control will not respond and the  red light will not turn off if the sensor window  Note  Finger must remain on the sensor is not fully covered by the finger   window until the door control acknowledges  that the finger has been scanned by sounding  a beep and turning off the red light  This will  take approximately 1 second        
8. r Controls are enrolled onto the network   go back to the  Controller application and click the    Secure Network    button     this safeguards the systems   if you select another tab on the aplication  this will happen automatically     Enable a User by ticking the    Enabled    box for each User  Assign a Name to the User  Assign a UserGroup from the drop down menu  The Usergroup will    determine the access levels for this User  Refer to section below on     Configuring Access Levels    for information on User Groups     Select each Door on the application and configure individual settings such  as Timed Actions  Relay Times  Ajar Times  Door Option and Alarm Options  etc     Assign a Card   PIN number and enrol FingerPrints for the User  Refer to  section FingerPrint Enrolment on page 19  Click    Save    to transmit these changes to the Controller     IMPORTANT  A timezone must be selcted in Timed Actions    for one of the  options  Card and PIN  Any Card  Card or PIN   or PIN only    lf all of these are set to    inactive    then access will be denied for all cards  and PINs on that Door Control     Example  Disabling cards  fobs  Enabling PIN codes only on a WI PINGProx  Set the Timed Action    Card or PIN    to    Inactive    and setting the Timed  Action    PIN Only    to    All day Every Day     This will grant access for PIN  codes and deny access for cards and fobs    To enable or disable Timed Actions at specific times  select a timezone  from the drop down list 
9. rol in the chain     Door Control Door Control   3  4  10    Note  If using a single Controller    RS485 Network to Controllers  an RS232 cable may be used  Max number of Controllers 3  Max cable length 10 meters Max Cable Length 1 4 km    Controller   2  3    50 meters  Controller   1  50 meters  50 meters  Door Control  50 meters  4    Door Control   1 Door Control   3  50 meters  5    0 meters  50 meters    Door Control   2    Note  Door Controls can be installed within 50 meters   of the Controller or within 50 meters of any other Door Control   as each Door Control will function as a repeater  Each repeater Door Control  transmits data to  from the Controller   5  10       41 Wiring Diagrams    Wiring Diagrams with  Local Door Connections       Network Diagrams ED    Network Diagrams for Single Controller    Sounder        DB9 Female  Serial Cable             a O      PC Network Connection     k uputs AO  can be used for multiple    Wie AG  controllers See page 2  7  A sono SS  10 for wiring z BERS  Use PC Direct     i  e   COM Connect DB9 cable  Connections if using   j  f  to serial port on PC  a single controller 1  ud  See page 9 for wiring      J  Maximum cable  P z  length 10 meters  3 P   S        I Wired 485 Networ e P  12V Linear z    Connections  a7    Power supply 2  AC al    PC Direct Connection can be used  when    B Q a  using ONLY one GSD Controller      S ye Set the Direct address to  7 ALL dip switches OFF   see below      Ele   Ne     SP  Zdi vVEckh    
10. the PC    Select the User for fingerprint enrollment    Click on the    Fingerprints    button         Click on    Enrol    tick box and place finger on the enrolment reader  An  image of the fingerprint will appear on the screen  Ensure that the image  quality is good and a value of at least 90  is achieved  Refer to section       Finger Placement    for correct finger placement and example of good  quality image  Repeat this process if this is not achieved on first attempt     Click    Save    using a good quality template only  Poor Quality templates can  lead to false rejections later when trying to gain access            L  Finger Placement Wi BIO Finger Placement Wi BIO P25    Correct Finger Placement Incorrect Finger Placement    Note  Incorrect placement   finger does not  fully cover the sensor window     YS coos Quality Image    Note  Ensure that the core of finger is ro  centered on the sensor window during  Enrol succeeded  Q 98  v  m  x   the enrollment process  This will increase    the quality of the fingerprint template AUAN  Note  Poor Quality image  No Fingerprint  y Linn    core on sensor window   M 6  j AN       X Poor Quality Image    l  Enrol succeeded  Q 76 Z  m  X      This can result in poor template quality that    Note  Good Quality image  Fingerprint core at NN   7 P f SSAIM EEUNA a a n   is center of sensor window f We jJj   HANS can lead to false rejection issues later when  ee jj   the user is trying to gain access     4  Note  The System does n
11. utomatic Backup Facility    Database Encryption       Installation Steps    Step  Description i Page    Install the Controller using the Installation Diagrams  W ire the Controller using the W iring Diagrams 8    Install and wire each Door Control  Refer to the Door Control E  Manual for instructions   4 Connect the Controller to the PC using Network Diagrams 9 11  Restoring Factory Defaults  Phase 1  Setting up the GSD Ccontroller    6  ee        J Installation Diagrams       Installation Diagrams   p    1  To open front cover of GSD Controller   remove screw cap using screwdriver  then loosen screw          3  screw the rear enclosure to the wall   as shown below     2 Remove door from unit   see inset  before screwing  the rear enclosure to the wall     To remove front cover lift tab up  and unhook door     4  Re attach the front cover    To re attach front cover  hook door  over top pip and rotate into  position and push tab down  to secure     Use for retaining cables     Note  If using a single Controller   an RS232 cable may be used   M ax cable length 10 meters    Place a120ohm  Termination Resistor  across A  amp  B onthe  Controller    RS485 Network to Controllers  M ax number of Controllers 3  M ax Cable Length 1 4 km    BS x    Controller   2  3    Controller   1    RS485 Network to Door Controls  Max Cable Length 1 4 km   Daisy Chain Configuration Only     Door Control Door Control    Place a 1200hm  Termination Resistor  across A  amp  B on the last    Door Cont
12. will now be in flicker mode as an indication   Repeat the process for all keypad Door Controls    Enter Engineer mode on each Wi Bio Door Control in the following way  Enter 6666  Enter 55   to default  Scan Finger to confirm   the Door Control will now go through the  process of defaulting itself   W hen this process has complete Scan Finger again to leave engineer  mode and to put the Door Control in the    Scan Mode      the Red Led  on the Door Control will now be in flicker mode as an indication   Repeat the process for all W i Bio Door Controls    Enter Engineer mode on each Prox Only Door Control in the following way  A  Addaprogramming card to the Door Control by presenting a card  twice on power up  The security wing must be removed first   Present this new programming card to enter Engineer mode   Present the programming card again to select    Default mode      Present any other card once to default the Door Control   W hen this process has complete the Door Control will be in the    Scan  M ode      the Red Led on the Door Control will now be in flicker mode  as an indication     Phase 3   Enrolling Door Controls    Step  Description O S    The controller is now ready to allow Door Controls to enrol onto the  Network   click the    Allow Doors to join this Controllers Network    on   the    Controllers    tab to start the controller scanning for new doors that do  not already have an address   only DoorControls without an address can  enrol   this will avoid other
    