Home
Press - Aer Conditionat Mitsubishi Electric
Contents
1. LLI S q Symptom Cause Remedy Check to see if the unit is on a slope or uneven surface N Move to a sturdy even surface 5 The operating Check to see if the pre filter is clogged noise is loud Clean according to the maintenance procedures 2 reverberates Operating the unit in small rooms or in tight spaces sometimes causes the sound to reverberate Place a mat underneath the unit The aoa l The sound increases when the compressor activates 3 minutes soun su enly after turning on the unit or during Automatic modes increases in volume The j unit The wind sound The volume of the sound differs depending on the angle of the makes changes in volume louvre noises The unit produces This is the sound of the refrigerant a simmering The sound can be heard while the refrigerant stabilizes after the sound unit turns on changes modes or stops The unit This is the sound of the compressor l ae produces a buzz In modes that monitor the humidity level or during drying inside that sounds the compressor operates intermittently causing the sound to be heard occasionally intermittently or The compressor does not activate after turning the unit off or for the compressor 3 minutes after plugging the unit into a power socket This is to g does not activate protect the compressor from damage 42 E A The heat converter heats rapidly causing a brief odour
2. e_mj_el4cg_sl_it indb 1 MITSUBISHI ELECTRIC DEHUMIDIFIER MODEL MJ E14CG S1 IT INSTRUCTION MANUAL Features Drying Inside Air Filter Easy Dehumidifying Intelligent Laundry In order to ensure correct usage please read this instruction manual carefully and retain it for future reference Before accepting the Warranty at the time of purchase please make sure that the date of purchase place of purchase and other items are correctly filled in the form Keep the Instruction Manual and Warranty in a safe place 3 English Italiano Table of Contents page Before using the unit Recommended Ways of Using the Unit Depending ON PUSPOSE seeeeeeeeeeseeeeeseeees 2 Frequently Asked Questions 3 PrecautiOnS cccceecceccececssccccccccccceccceceo 4 e Warnings aaooponobooqoadadadaciaoDoDEDDDODAdadadiooadeDDODONONOA 6 Tips on Dehumidifying Deiisscuiiseeecsoccssesecssecsscs 6 Names and Functions of Parts 7 Unit Control Panel LCD Panel Low Temperature Defrost High Humidity Things to Be Aware Of seeeeesseeseesseeesessseeeee 10 Before Using Your Dehumidifier 10 Operating Turning the Unit ON and OFF 12 To turn ON To turn OFF Reading the humidity display Tank full lamp J Easy Operation godoo g ononndadodog doononononovot d
3. The Mode Indicator goes out If the room temperature falls below 15 C defrosting mode is activated once every 40 minutes for about 5 minutes causing water to drain to the tank The unit can operate in a room temperature range of 1 35 C However if the room temperature exceeds 35 C the unit may operate in blower mode or increase the airflow This is because the temperature within the unit rises causing the protection mechanism to operate In order to lower the temperature within the unit when using the louvre point UPWARD e If the temperature is below 1 C the extracted water is close to freezing disabling the dehumidifier and only the blower is operational 12 e_mj_el4cg_s1_it indb 12 3 Reading the humidity display RILEVATA indicates the current humidity Current humidity range is between 30 80 e Humidity levels below 30 are displayed as 30 e Humidity levels above 80 are displayed as 80 Example Example rr IMPOSTATA indicates set Ltt x humidity level ued Auto mode only a ma TANICA PIENA Tank full lamp The unit automatically shuts down and indicates with the lamp and sound that the water tank is full Empty the water tank 21 Tank full lamp lights The unit beeps continuously e Air flows stops louvre stops Swing monitor turns off e Compressor turns off e After removing the water and replacing the tank the Tank full lamp will go off
4. This may cause overheating electric shock and or fire caused by an electric leak Do not use the unit in narrow enclosed places such as inside closets between pieces of furniture etc S M ni Do not use combustion appliances in the path of the air outlet This may cause incomplete combustion in the appliance This results in poor ventilation and may cause heat generation and or fire Do not use the unit in places where chemicals are used such as hospitals factories laboratories or beauty salons Chemicals and solvents evaporated in the air may harm the unit and cause water in the tank to leak resulting in damage to property Do not use the unit for special purposes such as preservation of food art or scientific works This may negatively affect oy the quality of the items stored e_mj_el4cg_sl_it indb 5 Do not drain water continuously if there is a possibility that wi temperature around the hose could drop to freezing point Water inside the hose may freeze and prevent the water in the tank from flowing out The water may leak from the unit and damage surrounding objects Do not use the unit in places that may be subject to oil or flammable gas leakage Such a leak around the unit may cause combustion and fire Do not remove the Styrofoam from the floating element The floating element will not be able to detect a full tank
5. 92 8 735 The OFF timer is set The following is an example of a display indicating AUTO dehumidifying set to 60 swing set to WIDE and the OFF timer set for 2 hours MINIMO ANTIMUFFA BASSA TEMP AUTO TIMER Z ai ORE ut I AE OSTATA The time remaining until the unit switches itself off is indicated in increments of one hour v When the set time is reached the unit switches itself off and the louvre closes automatically Drying inside will commence if it has been activated 7 18 i e_mj_el4cg_sl_it indo 18 3 The OFF timer can be set for 1 to 9 hours Set the timer when the power is switched on To cancel lt When you want to turn the unit off gt Press the POWER button Power off The OFF Timer is cancelled lt When you want to disable the OFF Timer mode and continue operation gt Keep pressed until the remaining time display disappears P The OFF Timer is cancelled Empty the water tank before operating The unit stops and the Tank full lamp lights if the tank becomes full during operation The OFF timer and ON timer cannot be set at the same time Do not use the OFF timer mode in conjunction with INTELLIGENT LAUNDRY or MILDEW GUARD The OFF timer cannot be set during drying inside 2013 06 22 we The ON timer can be set for 1 to 9 hours ON timer operation Set the timer when the power is switched off 42
6. This is not a produces z r The moisture expelled from inside the unit may smell due to an odour During drying odorants that were not caught by the air filter dissolving in the inside water This is not a malfunction lt p Error message Humidity indicator a He F N Digital display gt Cause Remedy a Check to see if the power cord is plugged into the power socket os Oa mc or x is displayed properly C ey Plug the power cord into the power socket properly 41 a Check to see if anything is blocking the air outlet Remove the obstruction and plug the power cord into the Pis displayed power socket again AN Check to see if the pre filter is clogged a Clean according to the maintenance procedures 23 i m m Malfunction m 0 crm co Ai AG or EL through EE Take note of the error message unplug the power cord and 2 is displayed contact the place of purchase J 8 S If the symptoms persist even after following the prescribed remedies or the error message does not 3 disappear unplug the power cord and contact the place of purchase 2 If the supply cord is damaged it must be replaced by the manufacturer its services agent or similar C qualified persons in order to avoid a i e_mj_el4cg_sl_it indo 27 hazard 3 NO N 2013 06 22 mi Specifications Model MJ E14CG S1 IT Power supply Single phase 220 240 V 50 Hz Dehumidifying capacity 14 L day
7. resulting in water leakage IS which may damage OT ndina y objects or cause electric shock and or an electric leak gt Do not wash the unit o with water Do not use the unit where it 2 is likely to come in O contact with water Exposure to water may result in fire or O electric shock caused by an electric o leak a ES Do not point air flow from the unit directly at the body If air flow is directed at the body for long periods it may harm one s Heater condition and ad to dehydration Install the unit in a location where the floor is flat and stable If the unit falls over the water collected in the water tank may leak damaging surrounding objects and in turn result in fire or electric shock caused by an electrical leak Grasp the plug and remove from the power socket When removing the plug from the power socket do not pull on it diagonally or by the cord N this may cause the projections wiring to be damaged resulting in a short circuit electric shock or fire Before moving the unit always switch it off unplug it and remove water from the water tank Moving the unit with water in its tank may cause the water to leak and damage the surrounding objects and in turn result in electric shock and or an electric leak 5 2013 06 22 i Precautions Cont A CAUTION After emptying the tank transport the unit by grasping the handle firmly Losing your foot
8. 15 3 To set 1 Switch the power off G2 2 Set the time you wish the unit to turn on Press once The Power lamp Mode indicator and a on the digital display flash The ON indicator lights e Each subsequent press changes the display in order from 1 to 9 hours Hold the button to run automatically through the numbers aaa foe 987 J 3 Select operating mode Select desired operating mode Set drying inside as desired 4 Change the louvre swing direction 16 Select the desired setting 5 Confirm the operating start time o POWER O OFF ON W Press Power lamp and Timer display light gt The ON timer is set The unit informs you if you forget to press the Power button by making the Timer display and Mode indicator blink and sounding an alarm for 1 minute i e_mj_el4cg_sl_it indo 19 3 The following is an example of a display indicating AUTO dehumidifying set to 60 swing set to WIDE and the ON timer set for 5 hours MINIMO ANTIMUFFA BASSA TEMP ae Z e The time remaining until the unit switches itself on is indicated in increments of one hour v e When the set time is reached the unit switches itself on To cancel Press the Power button o POWER O OFF ON Press The ON timer is cancelled Drying inside is deactivated when the ON timer is set during drying inside operation The ON timer function is not operable using a commercia
9. Power consumption 275 W Water tank capacity Stops automatically at approx 3 8 L Weight 11 7 kg Dimensions h x w x d 570 mm x 384 mm x 187 mm The dehumidifying capacity is a value obtained when the dehumidifier is continuously run at a room temperature of 32 C and humidity of 80 It indicates the amount of dehumidification per day 24 hours This symbol mark is for EU countries only This symbol mark is according to the directive 2002 96 EC Article 10 Information for users and Annex IV Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused This symbol means that electrical and electronic equipment at their end of life should be disposed of separately from your household waste Please dispose of this equipment at your local community waste collection recycling centre In the European Union there are separate collection systems for used electrical and electronic product Please help us to conserve the environment we live in Z CAUTION e Do not vent R134a into the Atmosphere e R134a is a Fluorinated Greenhouse gas covered by the Kyoto Protocol with a Global Warming Potential GWP 1300 Fill in the following for your future reference Place of purchase Telephone number Authorised Service Centre Telephone number Date of purchase Month MITSUBISHI ELECTRIC CORPORATION e_mj_el4cg_sl_i
10. and the unit will automatically return to operation mode e When the Tank full lamp is lit no operation but OFF ON is possible 2013 06 22 tae Easy Operation The unit automatically monitors room temperature humidity alleviating the necessity to make minor adjustments Use EASY DEHUMIDIFYING for dehumidifying a room and INTELLIGENT LAUNDRY for drying clothes Changes with every press BENESSERE a BUCATO_ W Press Selected mode lamp lights EASY DEHUMIDIFYING The unit operates intermittently controlling the airflow to remove the damp feeling in the air There is no need A gt to set the humidity level When the room temperature is high the blower operates to decrease the damp feeling The airflow or louvre operation may stop according to the humidity level ES 50 Room 20 2730 temperature C Room temperature is Room temperature is below 27 C the unit above 27 C the unit automatically sets the lowers the humidity level humidity level according to 50 then activates to the temperature the blower The dehumidifier is reactivated when humidity rises to 60 Pressing Humidity Selection button while in EASY DEHUMIDIFYING or INTELLIG mode to AUTO 25 i e_mj_el4cg_sl_it indbo 13 3 INTELLIGENT LAUNDRY The unit controls the airflow rate while monitoring the humidity in the room and automatically stops operation when the laundry is dry
11. heaters etc amp The plastic parts may melt and cause fire Wipe dust off the power plug and insert the plug firmly If the plug is not fully inserted into the socket dust may gather on the maan connectors which may cause fire and or electric shock Use 220 240V AC power sockets Connecting to power sockets other than 220 240V AC may result in fire and or electric shock Remove water that has collected in the tank Accidentally drinking the water or using it for other purposes may cause illness and or unforeseen accidents Should abnormal symptoms occur a burning smell etc switch off the unit and unplug it from the socket Continuing to operate the unit may result in fire electric shock or malfunctions Contact your dealer or Mitsubishi Electric Service Centre for consultation 2013 06 22 mi ZA CAUTION Do not cover the front or side air intakes or the air outlet with cloth curtain etc This results in poor ventilation and may cause heat generation fire Do not stand on sit on or lean against the unit The unit may tip over causing injury Do not put vases or any other objects filled with water on the unit Water may leak into the unit adversely affecting electric insulation and cause electric shock and or fire by short circuiting Do not use the unit where it may be exposed to direct sunlight or other weather conditions This unit is for indoor use only
12. right of the unit Installing your dehumidifier Make sure to leave some ell At least 50 emf space around the unit lt For use in close proximity to a wall gt Stop the louvre in the vertical position Blowing air at the wall may cause staining Operating noise Place the unit on top of a mat This reduces vibration and noise It also prevents leaving depressions on carpets At least 20 cm Keep the unit always in an upright position Inclining the unit may cause water in the tank to leak into the unit resulting in malfunction Should this happen contact service number on the last page for advice Damage to the dehumidifier caused by atmospheric conditions ie Salt or Sulphur will not be covered under warranty 6 e_mj_el4cg_sl_it indb 6 3 Do not carry or store the unit horizontally This may result in malfunctions Such malfunctions are NOT covered under warranty 2013 06 22 re Names and Functions of Parts Front Set before use Control panel Air filter Supplied with unit SD x e_mj_el4cg_sl_it indb 7 WT VTE ANNUAL WA iitty INAAARRRRN Wit Will WS is Vf A Water tank Tank lid Floating element 21 Front door Louvre Do not block Sensor Do not cover Continuous outlet Handle Raise handle to transport S
13. usage and environmental conditions Remove the front panel and pre filter to replace the air filter For maintenance procedures see Parts sold separately Air filter for replacement Type MJPR ECGFT Type code 5C7 859 For these items contact your nearest Mitsubishi Electric dealer e_mj_el4cg_sl_it indb 25 3 Storage and Disposal LI Storage After switching the unit off leave for one day until any water inside has had time to run off then carry out the following steps 1 Perform drying inside 77 Performing drying inside to prevent mildew growth is recommended 2 Bundle r power cord 3 Remove the drainage water 21 Empty the water tank and wipe away any remaining lt gt drops of water 4 Clean the pre filter 23 Remove grit with vacuum cleaner 5 Store the unit e When you are sure that all parts of the unit are dry cover it with a cloth to keep it from dust e Store the unit in an upright position in a place not exposed to direct sunlight When disposing the unit Dispose according to the garbage regulations in your district Air filter Material PET and PS e Unit E Do not disassemble Dispose according to 3 the garbage regulations in your district re 8 L NO OI 2013 06 22 re Troubleshooting For the symptoms listed below refer to the remedies listed right Symptom Cause Re
14. Stop swin The swing monitor turns off louvre at the p g desired operation To change the louvre to a desired angle wait until the gt esired angle louvre stops then adjust by hand DaN To cover the e WIDE AY The louvre swings from the UPWARD position through to entire room Ss the REAR position Swing speed is automatically controlled to send air at _ washing from all angles Fordi Ng The lowly through or rying X d e louvre moves siowly throug e UPWARD OO the last 30 of the swing as the clothes etc time taken to traverse the rear arc is shorter than that for the upward arc when moving at a constant speed For directing air s 9 e REAR oA into a closet Ni The louvre may stop up to a maximum of 8 seconds to correct its position after which it will start moving again The level of noise emitted from the unit varies according to the angle of the air flow f the louvre is knocked out of the desired angle readjust by following the above steps Stop the louvre in the vertical position when using the unit against a wall Blowing air at the wall may cause staining e_mj_el4cg_st_it indb 16 T 2013 06 22 oral i Drying Inside Operation The inside of the unit can be dried to suppress mildew growth on the cooler On days the dehumidifier is used drying inside is recommended m Lu Automatic operation Manual operation To activate drying i
15. This eliminates the need to make minor changes to the humidity and operating time settings depending on the amount of laundry Operation is performed for a maximum of approximately 12 hours Drain the tank before use The unit may stop before the laundry dries because of a full tank Do not use in conjunction with the OFF timer The timer may turn the unit off before the laundry dries If the room temperature is approximately 5 C or less the operation stops for around 1 hour If the room temperature is low it becomes difficult for water to evaporate from the laundry because the humidity does not change Use a heater in combination with the unit in order to raise the room temperature to approximately 16 C or more The following conditions prevent clothes from drying well Room temperature below 15 C large volume of laundry laundry not spaced well clothes with thick fabric and large rooms Ss LI P 8 2 e q ENT LAUNDRY mode changes the 2013 06 22 ma 13 i Setting Modes LOW MILDEW GUARD and LOW TEMP LOW mode is for when you want to leave the dehumidifier on MILDEW GUARD mode suppresses mildew growth LOW TEMP mode is for preventing condensation or when the room temperature is low MINIMO Ww ANTIMUFFA v BASSA TEMP v AUTO Changes with every press Frame appears around selected mode The amount of dehumidification decre
16. ad 13 EASY DEHUMIDIFYING INTELLIGENT LAUNDRY e Setting EY ES noonoo 14 LOW MILDEW GUARD LOW TEMP AUTO AIR PURIFIER Using LOUVI occccscccccccccccccscssccccvcccscccccccssces 16 J Drying Inside Operation 000000000000000000000000000 17 e Using TIMEr ooccccccccccccccccsccccccccsccccscccescccs cece 18 OFF timer operation ON timer operation J Using litle Lyeyel Koccnsccccnsncnonsc0ccn9cN99NE0NI0R0 20 J Carrying Td ne UAV it ee 20 e Draining 00000900000000000000000000000000000000000000000000000 21 Continuous Drainage 0000000000000000000000000000000 22 Troubleshooting Maintenance cccccccscccssccccccccecccscccscccccecs 23 Replacement Parts eeeeeseeeeeeeeeeeeeeeeeeeeeecceee 25 Storage and Disposal eeeeseeeeeeseeeeeeeeeeceee 25 J Troubleshooting 600060000000000000000600000000000000005 26 J Specifications 0000 00000000000000500000000000000500000000 28 2013 06 22 rl i Recommended Ways of Using the Unit Depending Combine operating mode and swing louvre function to get optimum results Drying MeT laundry Lowering room humidity Preventing mold When you don t When you don t When you want to When To prevent want to hang know what set the humidity condensation mildew occurs indoors clothes outside or humidity level to level it is raining set the unit to want to What i should l 60 set it to INTELLIGENT LAUNDRY The unit operates autom
17. ases with the temperature and humidity 3 The humidity level cannot be set with LOW MILDEW GUARD and LOW TEMP LOW The dehumidifier operates regardless of the humidity level p e MILDEW GUARD The unit lowers humidity levels automatically once a day suppressing gt mildew growth The unit operates intermittently for 2 4 hours a day 24 ON hours The operating time varies depending on the humidity 24 hours 24 hours The unit continues to operate when the humidity does not p_e decrease Standby e Humidity 40 gt Approx 2 hours e Humidity 50 gt Approx 4 hours Dehumidifies Dehumidifies Refrain from turning on ventilation fans or opening windows or doors as this lowers performance Mildew growth may still occur due to the fungus type and conditions of the room E g Rooms that contain excessive condensation bathrooms and places with bad airflow insides of closets and behind furniture This mode does not remove existing mildew Do not use in conjunction with OFF Timer mode Effects may not be achieved LOW TEMP Tre unit operates continuously automatically controlling airflow according to room temperature The air flow is strongest below 15 C The use of LOW TEMP mode is recommended when the Low Temperature indicator 3 is lit 3 When the temperature is low condensation may still form on windows exposed to the outside air even when LOW TEMP mode is operating How is mildew Mi
18. atically until the laundry is dry UPWARD EASY DEHUMIDIFYING The unit operates The unit maintains until the air is the set humidity comfortable LOW TEMP MILDEW GUARD The unit changes the The unit operates airflow according to in mildew room temperature suppression mode Any swing setting Any swing setting Aim toward clothes Procedure Press the power button the unit turns on Page 12 Turn the power on Turn the power on lt lt Switch to Select the HUMIDITY mode SELECTION Page 13 15 N Set the Select Select INTELLIGENT Select EASY YW humidity LOW TEMP LAUNDRY DEHUMIDIFYING lt D Select the louvre swing ore range N Page 16 Select UPWARD Select any swing setting Select any swing setting 2 e_mj_el4cg_sl_it indb 2 cb 2013 06 22 eee on Purpose To clean condensation mea There is no need for dehumidification but you wish to remove pollen and dust from the air To keep the inside of closets and shoeboxes dry LOW AIR PURIFIER The dehumidifier The unit operates the air operates regardless purifier only of the humidity level REAR Z Direct te Any swing setting air flow Turn the power on lt PURIFICATORE D ARIA Switch to AIR PURIFIER Select LOW yy Select any Select REAR swing setting e_mj_el4cg_sl_it indb 3 Why does the dehumidif
19. e in DEFROST mode airflow dehumidifying and the louvre will stop The sounds coming from the unit will also change DEFROST will start automatically when room temperature drops below 15 C This may be as often as once every 40 minutes All modes include dehumidifier and air purifier functions Air purifier only operation The dehumidifier function is disabled Before using the unit High Humidity Warning The yy indicator flashes when the unit is OFF and the humidity in the room exceeds 75 Activating the dehumidifier is recommended when the yy indicator is flashing If the High humidity warning is not required remove the power plug from the power socket 9 2013 06 22 cee e_mj_el4cg_s1_it indb 10 Things to Be Aware of Room temperature may rise 2 4 C during operation The dehumidifier does not have a cooler function Due to heat produced during operation the room temperature may rise 2 4 C As a result the unit may blow warm air but this is not due to a malfunction During winter the air may not feel warm as the temperature is below body temperature How does the dehumidifier work If you pour cold water into a cup the air around it becomes cold causing water droplets to form on the surface of the cup The dehumidifier takes advantage of this phenomenon to remove moisture from the air The unit draws air from the room cools it
20. emove the front panel and 4 Dry the air filter pre filter Front panel Pre filter Do not hang with pegs as this may damage the filter Do not use the filter while wet 5 Fit the air filter With the strips facing up set the air filter inside the tabs on the pre filter 2 Remove by i Waa holding the Linh Performance is oe a unaffected even if the metal fins inside the main p unit are slightly bent Tabs 6 I j 2 Remove the air filter Remove by holding the bottom SS SS panel 3 Soak the air filter in water Soak in cool to lukewarm water for 30 minutes Attach by holding 2 Hook the top edge the tabs to the top part of the unit and push the bottom in Do not use detergent or hot water Also do not brush or rub while soaking as this may damage the filter e Stains may remain on the filter but should not affect performance e The filter can be soaked for a total of eight times After that replace with a new filter 24 e_mj_el4cg_sl_it indb 24 5 2013 06 22 onl Replacement Parts The air filter is a consumable item Replace the filter when it becomes time for replacement Replacing the air filter Although the air filter lasts roughly 2 years replace it when e You have soaked the filter 8 times e The air filter has turned brown due to cigarette smoke or black with dust Filter life differs on
21. he direction Displays the time AUTO mode of the swing louvre set for the ON The humidity is displayed in a OFF timer range from 30 to 80 Child lock indicator Displayed while child lock is active 8 e_mj_el4cg_sl_it indb 8 5 2013 06 22 Pi O Ne he INTERNA o POWER OFF ON D ARIA Power lamp Lights when unit is ON Power button Use this to switch the unit ON and OFF Tank full lamp This lights up to warn that the water tank is full Information display Indicates room and unit condition Low Temperature ER Indicator The indicator comes on if the room temperature drops below 15 C Activating LOW TEMP mode is recommended e_mj_el4cg_sl_it indb 9 MJ E14CG S1 IT ASCIUGATURA PURIFICATORE Drying inside lamp Flashes when drying inside i Drying inside button n progress Activate deactivates drying inside Air purifier lamp Lights during air purifier only operation Air purifier button Switches to air purifier only operation EA You can select from 7 operating modes e EASY DEHUMIDIFYING INTELLIGENT LAUNDRY e LOW e MILDEW GUARD e LOW TEMP e AUTO e AIR PURIFIER ie DEFROST Indicator Airflow dehumidifying will stop and the frost that has accumulated inside will be melted and dropped into the tank when the 3 indicator is on Please wait a moment as operation will resume in around 5 minutes Whil
22. ide air intakes left right drainage eo co Pre filter 25 LLJ Front panel Front air intake Do not block f 3 o fa pe D o 2 oO 3 RA SEE It is impossible to remove the back panel because the two spots shown are fastened with two special screws If the unit malfunctions contact your Mitsubishi dealer The water tank may contain water residue at time of purchase This is from final product testing at the factory and is not due to a defect 2013 06 22 vowel i Names and Functions of Parts Cont Control Panel BENESSERE SELEZIONA SNE S UVELLOD 00 UMIDIT Los IN OSTATA Lamp Mode button Swing louvre button Current mode lights For switching from one Sets swing louvre Selection button operating mode to another direction or locks it into Switches modes Humidity selection position button This is used to set the target humidity Child lock To set the child lock press the mode lt b button for three Maan seconds LCD Panel All indicators on the LCD panel shown below Mode indicator MINIMO Indicates the current operating mode SNTIMUFFA BASSA TEMP AUTO RILEVATA Humidity indicator This indicates the approximate humidity indicates the current humidity indicates the Swing monitor Timer display humidity setting in Indicates t
23. ier seem to collect less water in winter s A When the temperature and humidity are low the amount of water collected is decreased In winter because the temperature is lower than in summer the effect of the dehumidifier decreases dramatically as shown in the graph below Although less water collects in the tank this is not a malfunction If the temperature is low but the humidity is high due to snow or rain operating the unit in LOW TEMP mode will yield better results than in LOW mode Value for LOW when humidity is 80 Dehumidification capacity L day 0 5 10 15 20 25 32 Room temperature C e The values shown on the graph were measured at constant temperature and humidity and do not reflect values obtained in actual usage conditions 3 e Why doesn t the dehumidifier operate e Why does the unit stop operating suddenly ie N A The unit might be in INTELLIGENT LAUNDRY mode The unit may sometimes stop operation after just a short amount of time as a result of conditions such as the room temperature and humidity A The unit might be in EASY DEHUMIDIFYING MILDEW GUARD or AUTO mode The unit automatically switches between dehumidifying airflow only and non operation es Before using the unit 3 2013 06 22 rl 9 i Precautions The following diagrams indicate circumstances where danger can result from mishandling
24. ing while carrying the unit may cause personal injury or damage to the floor When using the continuous drainage outlet make sure to position the hose so that the water drains without obstruction The water in the tank may leak and damage surrounding objects When draining water continuously or left unattended for long periods inspect the unit every two weeks Do not allow debris to clog the filter nose as this may cause overheating leakage Use the unit with caution in rooms where the walls furniture and art work are vulnerable to dry air as it may cause cracks and warping Switch the unit off and M5 unplug from the power eh source when cleaning it When the unit is on the internal fan rotates at high speeds and may cause injury Unplug the unit from the power source when not using the unit for an extended period of time Otherwise it may cause fire and or electric shock caused by an electric leak Warnings Tips on Dehumidifying Drain the water tank before use Refrain from opening doors windows during operation Drying laundry indoors e Direct the louvres at the laundry e Space laundry to improve airflow Use the dehumidifier in a small enclosed room Maintain room temperature above 16 C with a heater Drying times will vary depending on the nature of the on laundry and the room temperature The airflow is strongest to the top
25. isture expelled from inside the unit may cause the humidity level of the room to rise D The air leaving the unit may appear white depending on the humidity or temperature of the room 6 The moisture expelled from inside the unit may smell due to odorants that were not caught by the filter dissolving in the water The air filter is mainly for absorbing ammonia The OFF timer cannot be set during drying inside lt Drying inside operation gt This operation takes approximately one hour However when the room temperature is below 1 C drying time is shortened to protect the compressor OFF Drying inside operation approx one hour Regular operation Airflow Airflow Airflow stops compressor activates operating sound Compressor operates Approx according to room temperature Approx 20 min 10 min Operating Compressor Dehumidifier sounds stops Air purifier Approx 30 min 17 2013 06 22 re e_mj_el4cg_sl_it indb 17 i Using Timer OFF timer operation To set 1 Switch the power on 22 2 Select operating mode Select desired operating mode 3 Change the louvre swing direction 16 Select the desired setting 4 Set the operation time Press When pressed once the figure and OFF appear Each subsequent press changes the display in order from 1 to 9 hours Hold the button to run automatically through the numbers fo
26. ldew is unable to produce new spores if dried as mycelia The Mildew Guard feature grow suppressed applies this principle However the spores themselves are resilient to dry conditions Identification of Aspergillus and Penicillium lt Research paper by Dr K Abe of the Environmental Biology Research Center gt 14 e_mj_el4cg_sl_it indb 14 5 2013 06 22 ne AUTO When you want to set the humidity level AIR PURIFIER To operate only the air purifier MINIMO ANTIMUFFA BASSA TEMP AUTO Press e Frame appears around AUTO The MODE button can also be used to select AUTO e AUTO The unit maintains the humidity level by automatically controlling airflow and operating intermittently as necessary All you have to do is set the humidity level e The unit turns off when current humidity decreases past the set humidity level and restarts when the level is exceeded airflow and louvre stops e The unit operates for 6 minutes continuously regardless of the humidity level immediately after turning the power on lt To view set humidity level To set humidity level gt e Pressing the button once displays the set humidify level with the indicator After 3 seconds the display returns to the current humidity display Frequent use of exits and room size conditions may cause the humidity to not reach the set level e Pressing the button while is displayed set
27. lly available timer plug outlet 2013 06 22 al LLI P amp 19 Using Child Lock To lock Press for 3 or more seconds The child lock indicator lights up The child lock is switched off when the power cord is unplugged When the child lock is activated the other switches are inoperable Deactivate the child lock to use the other buttons If you lock the unit when the POWER is OFF The unit will not turn on even if you press the POWER button to turn it on Only the CHILD LOCK lamp will blink Press the POWER button once again so that the lamp lights If you lock the unit when the POWER is ON The unit will not turn off even if you press the POWER button to turn it off Only the CHILD LOCK lamp will blink Press the POWER button once again so that the lamp lights Releasing the child lock Press for 3 or more seconds The child lock indicator turns off 20 e_mj_el4cg_st_it indb 20 Carrying the Unit Pull the handle out and grasp with a firm grip Before moving the unit first make sure to remove water from the water tank and close the louvre Do not carry the unit on its side as this may cause malfunctions Do not let the power cord drag as this may damage the cord 2013 06 22 al i Draining The unit automatically shuts down and lights the Tank full lamp when the tank appro
28. medy D A a trough nating co gaina Rto warm pyy Check to see if the temperature humidity is low N Water does not collect in the water Low room temperature humidity reduces dehumidifying effectiveness E the amount oi water colected Ine tsnotamatunction FS Check to see if the power cord is correctly plugged The unit does not turn on no air comes out Plug the power cord properly into the power socket Check to see if anything is blocking the air intake or outlet Remove the obstruction The unit keeps turning off Check to see if the pre filter is clogged Clean according to the maintenance procedures Stops after a short time Check to see if the unit is operating in INTELLIGENT LAUNDRY mode The unit may sometimes stop operation after just a short amount of time as a result of conditions such as the room temperature and humidity Louvre does not swing Check to see if the unit is in EASY DEHUMIDIFYING MILDEW GUARD or AUTO The unit is automatically controlling the dehumidifier fan and standby times S EA Ka pe OTANICA PIENA lights Check to see if the water tank is full Empty the water tank and return it to its original position Check to see if the water tank is inserted properly Adjust the position of the water tank pn q sis indicates L Check to see if the unit is in defrosting mode The unit activates def
29. nside after every use To activate drying inside by pressing a button ASCIUGATURA x 7 ASCIUGATURA e e INTERNA a 3 A ina Press while the unit is on Press while the unit is off Drying inside standby Drying inside starts Drying inside lamp lit The Drying inside lamp flashes the humidity indicator turns off and the louvre stops in the Wy vertical position Drying inside starts when operation Drying inside mode enas When the unit is turned off INTELLIGENT Drying inside ends LAUNDRY mode ends or the OFF timer ends The Drying inside lamp turns off and the os louvres shut e Drying inside starts The Drying inside lamp flashes the humidity z indicator turns off and the louvre stops in the To abort drying inside vertical position ave _ Se Press the drying inside button while the unit Drying inside mode is performing drying inside the Drying inside r TER lamp turns off e Drying inside ends i The Drying inside lamp turns off and the Press the power button to abort drying inside louvres shut and resume normal operation ne lt To deactivate automatic operation gt Press the drying inside button while the unit is on the Drying inside lamp turns off Connecting disconnecting the power plug deactivates automatic operation This function does not remove existing mildew Also aborting drying inside may cause the benefits to diminish Do not close the louvres while drying inside as this causes noise The mo
30. nt How to set up the drainage hose Water inside the hose may freeze and water may leak Incorrectly Hose immersed in from the unit and damage surrounding objects installed water Hose raised to a level higher than the drainage outlet gt The water will not drain Correctly installed 7 When draining water continuously or left unattended for long periods inspect the unit once a fortnight Foreign objects etc could clog the hose resulting in overheating and or leakage 4 Insert the hose into the drainage outlet on the back Feed the commercially available hose ID 15 mm into the drainage outlet while keeping the stopper pressed Open the front door Grasp handle and pull out 2 Open the drainage outlet Position of drainage outlet Feed the hose into the drainage outlet Use cutters to cut the three fixing ribs of the continuous drainage port on the back of the main unit then remove it carefully making sure that it does not fall inside the unit Confirm that the hose is 3 Press drain stopper securely attached and does not leak 5 Replace the tank and set the end of the hose in the drain The unit cannot operate without returning the tank Push here Confirm that the hose does not show signs of deterioration such as cracks and clogging Leave a minimum space of 20 cm behind the unit for attaching the hose Inspect the hose every 2 weeks Insects
31. or dirt blocking the hose may cause leakage resulting in malfunctions 22 e_mj_el4cg_sl_it indb 22 5 2013 06 22 mi i Maintenance Do not use detergents cleaning agents for heat exchange equipment abrasive powders chemically treated dusters gasoline benzene thinners or other solvents as they can damage the unit or the water tank which may result in LLI leakage Cleaning Once every two weeks Water tank Main unit Pre filter Debris clogging the pre filter reduces the Wipe with a soft cloth effectiveness of the dehumidifier Clean once every 2 weeks For maintenance procedures see 1 Remove the front panel and pre filter Figating element 2 Remove the air filter Do not remove or dismantle 3 Clean the pre filter Remove grit with vacuum cleaner me 4 Fit the air filter The unit draws in dust present in the air and this 5 TT the pre filter and front may cause the tank to gradually become dirty panel If the dirt does not come off easily wash with S cold or warm water then wipe with a soft dry cloth z Mildew may form in the tank unless kept clean E ae pe D fe D 2 2 Ss 2 L gt NO 09 i emj_el4cg_sl_it indo 23 5 2013 06 22 re i I Maintenance Cont Once every three months a Soak the filter in water about once every three months Air filter For maintenance procedures see 1 R
32. r filter inside the tabs on the pre filter Attach holding the tabs 2 Hook the top edge to the top part of the unit and push the bottom in 2013 06 22 rl P Dehumidifier Inserting the water tank correctly Tank Lid Confirm that the lid is securely attached to the water tank Push the tank in Front door e_mj_el4cg_st_it indb 11 Open the front door m f Plug the power cord into the power socket Use a 220 240V AC power socket only The current humidity level is indicated If the louvre is open it closes automatically Before using the unit 11 2013 06 22 sea I Turning the Unit ON and OFF To turn ON o POWER OFF ON Press Power lamp lights The mode is displayed The louvre opens automatically To start dehumidifying select the desired mode The dehumidifier does not activate for 3 minutes when the unit is turned ON immediately after turning it OFF or plugging it into the power socket In order to protect the p compressor When dehumidifying begins the operational noise increases The dehumidifier remembers the operating mode Even if the plug is disconnected or the power turned off the unit restarts at the previous setting To turn OFF o POWER OFF ON X Press Drying inside will commence if it has been activated 17 Power lamp turns off
33. rosting mode when the room temperature drops below 15 C The dehumidifier and blower functions stop during defrosting The unit continues to operate even though it is turned off Is the unit set to drying inside mode This function activates automatically after the unit finishes operating an Sa RA A 7 The humidity level does not reach the level set a Check to see if the room is not too large Check to see if the exits to the room are open Refrain from opening doors windows during operation Check to see if steam producing appliances such as kerosene heaters are on in the vicinity The hygrometer reading on the unit differs from other hygrometers in the room Hygrometer readings differ from place to place even if in the same room Use the unit humidity reading as an estimate R SN fa ine louvre does not move as set Press the Swing louvre button again A 7 The water tank contains liquid or white water residue The residue is from final product testing at the factory It is not a result of a malfunction FN 7 There is black residue on the inside of the water tank and lid The residue is from debris in the air Clean according to the maintenance procedures Hf Na 26 e_mj_el4cg_sl_it indb 26 3 2013 06 22 rl
34. s the humidity level Each time the button is pressed the humidity setting changes 70 gt 65 gt 60 gt 55 gt 50 a o i e_mj_el4cg_sl_it indo 15 O QO D m J5 a PURIFICATORE D ARIA Press e Air purifier lamp lights To return to the previous mode press the air purifier button again e AIR PURIFIER The unit cleans the air by passing it through the pre filter and air filter The dehumidifying function is disabled The air passes through the air filter in all modes cleaning the air even if the air purifier lamp is not lit Cigarette smoke and toxins found in smoke such as carbon monoxide cannot be removed with these filters Operating 15 2013 06 22 ee Using Louvre how to read the swing monitor The louvre can be made to swing Select from the 4 possible settings to suit the purpose Starts swing operation The swing monitor is displayed The swing operation stops when the power cord is unplugged This indicates the range of louvre swing The louvre and monitor do not move in synchronization Stop swing operation 2N WIDE lt a VQ 4 LL F7 Sor iS L With each press of the button ZA E 4 A 1 Ei g lt 7 UPWARD 9 4 vy 4 S REAR Objective Recommended swing setting Explanation of the swing modes To stop the The louvre stops in a vertical position e
35. t indb 28 5 2013 06 22 mi
36. the unit Z N WARNING N CAUTION Mishandling may result in fatal or serious injuries Mishandling may result in minor injuries or damage to your home or property etc Meanings of the graphic symbols used in this manual and on the unit are explained below i Do not S Forbidden Q disassemble Always follow the instructions Keep ae Do not away from Ng subject to fire water Z WARNING Do not start stop the unit by plugging unplugging the power cord This may result in fire and or electric shock Do not use extension cords or multiple head adapters S This may result in fire electric shock or malfunctions Do not damage or modify the power cord or plug Do not modify bundle twist bend or heat the power cord Do not place under objects or use with the end close to the plug bent Keep pets from biting the cord D The cord may be damaged resulting in fire or electric shock Do not put your fingers or any long object into the air intake outlet Do not touch the swing louvre N The internal fan rotates at high speeds and such actions may result in injury or malfunctions Do not attempt to repair disassemble or modify the unit S Sa dar is X This may result in fire and or electric shock Refer servicing to your dealer or Mitsubishi Electric Service Centre 4 e_mj_el4cg_sl_it indb 4 Do not put the unit near heat generating devices such as stoves fan
37. with its cooling coil causing the moisture to transform into water droplets The water droplets fall into the water tank 3 The dehumidified air is reheated by the heating coil and then discharged The humidity of the room is thus reduced by repeating steps and Dried warm air Cooling coil Re heating coil Compressor N Sn Water tank The humidity reading on the unit may differ from a hygrometer in the same room Even in the same room temperature and humidity levels may differ from place to place If the hygrometer and the unit are in different parts of the room the humidity levels are prone to differ Moreover humidity levels differ between places that have good and no airflow Use the reading on the unit as an estimate ey di DP Y eren lt Cause gt Inconsistencies in temperature and humidity Difference in location Difference in hygrometer accuracy Before Using Your Setting the air filter The air filter is supplied with the unit at time of purchase Fit the air filter before using the unit 1 Remove the air filter from the polyethylene bag 2 Remove the front panel and pre filter Front panel Pre filter Remove holding the bottom the tabs Performance is unaffected even if the metal fins inside the main unit are slightly bent 3 Fit the air filter into the pre filter With the strips facing up set the ai
38. ximately 3 8 L is full Lu Empty the tank 1 Remove the water tank 2 Remove the tank lid and empty Tank lid Open the front door Floating element Do not remove or dismantle the float Grasp handle and a Pour the water out slide out NY as shown lt p N a lt Hold the tank this way gt 3 Reattach the tank lid and replace the water tank D S 5 o Confirm that the lid is securely attached to the water tank and push the tank in Close the front door f the lid is not properly closed you may have problems removing the tank f the tank is not installed correctly the tank full lamp will come on and the unit will not operate tank If it is removed the unit cannot detect when the Do not remove or dismantle the floating element in the tank is full and this could result in leakage 21 e_mj_el4cg_sl_it indb 21 5 2013 06 22 a i Continuous Drainage If a drain is available the unit can continuously drain excess water by attaching a commercially available hose internal diameter 15 mm The unit can be operated for extensive periods without the need to empty the water tank gt S Commercially available hose ID 15 mm Ne AUTION ee 2 Long enough to reach the drain 3 Side Cutters 32 Do not drain water continuously if there is a possibility that temperatures around the hose could drop below freezing poi