Home

REuSABlE HIGH TEMPERATuRE CAuTERY WITH REPlACEABlE

image

Contents

1. E MONOPOLAR HANDLES WITH OR WITHOUT SWITCHES GIMA autoclavable electrosurgery pencils with CUT COAG switch have been studied and tested to offer maximum reliability and functionality to the operator MB handles are provided with a 3 Pins socket Valley Lab type that fits all Gima mono bipolar Diatermo MB 122 132 160 200 202 240 250 380 400 and majority of bipolar electrosurgical units Aspen Lab ES Generator EMC Statome Danieli Braun Berchtold Ohmeda Ritter Conmed Eschman Bovie Martin Kontron Bard Birtcher 771 Cobi Valley Lab Led Erbe e 30554 MB AUTOCLAVABLE HANDLE 100 times Autoclavable handle with 2 large click push button provided with a 3 meters long silicone cable and a blade electrode It can be autoclaved up to 100 times 20 times electrode For electrodes 2 4 mm e 30550 PRIMA MB AUTOCLAVABLE HANDLE 60 times Autoclavable handle with 2 large click push button provided with a 3 meters long silicone cable and a blade electrode It can be autoclaved up to 60 times For electrodes 2 4 mm e 30548 STAR AUTOCLAVABLE HANDLE 30 times Same as code 30554 but autoclavable up to 30 times electrode is autoclavable up to 20 times For electrodes 2 4mm e 30549 STAR 5 AUTOCLAVABLE HANDLE 30 times MB HANDLES 547 screw type autoclavable up to 100 times 30553 Tripolar universal Valleylab type connector for all above handles Same as STAR bu
2. E CHANGE A TIP CAUTERIES WITH HIGH TEMPERATURES AARON CAUTERIES made in USA Interchangeable sterile tips Replaceable batteries Reusable handles 30590 P MEDI at company No sterilization necessary Tip not included a GIMA INTERCHANGEABLE TIP CAUTERIES Recommended ga MINIMUM ORDER 10 TIPS iii 30590 Cautery handle AA tip not included All tips g eee bom C lt 0413 30593 High temp loop tip sterile DER ENT 30594 i 30594 High temp 2 flex loop tip sterile GYN ENT er 30595 High temp 5 loop tip long size sterile GYNAECOLOGY lt see 30596 High temp fine tip sterile DER CARDIO 30596 30593 mM REUSABLE HIGH TEMPERATURE CAUTERY WITH REPLACEABLE TIP CAUTERIES 1 200 C 2 200 F made in Italy 30598 oo Interchangeable tips with nickel crome wire Pe IRE TN m 55555 E LO a Replaceable batteries Reusable handles 32 3 3 man Wide application in gynaecology orthopedies ear nose throat 4 a 8 ene GIMA INTERCHANGEABLE TIP CAUTERIES code MINIMUM ORDER 10 TIPS 30599 30598 Cautery handle AA tip not included _ 30599 High temp long fine tip sterile box of 10 ii hiis 30600 High temp large tip sterile box of 10 30601 E 30600 30601 High temp fine tip sterile box of 10 C 0086 WM HIGH TEMPERATURE ELECTROCAUTERIES e 30580 ELECTROCAUTERY 1 200 C fine tip made in Italy The Electrocautery is a sterile bipolar bat
3. includes a useful repeat function which enables the user to repeat set impulses from 2 to 9 times and a timer to monitor the elapsed time of the treatment or the whole operation Complete safety an acoustic alarm intermittent beep and a blinking red led on front panel warns user that the neutral plate is unplugged or not in contact with the patient or the cable is disconnected In this case HF emission for cut and coagulation operation is switched off TECHNICAL SPECIFICATIONS Minimum preselectable power 0 Level step 1 Maximum output power CUT W 120 2500 Maximum output power BLEND W 90 2500 Maximum output power COAG FORCED W 80 2500 Maximum output power COAG SOFT W 60 2500 Maximum output power BIPOLAR W 40 2500 Crest Factor CUT 5 Crest Factor BLEND 2 1 Crest Factor COAG FORCED 2 0 Crest Factor COAG SOFT lee Crest Factor BIPOLAR 15 Working frequency 600 kHz Weight Kg 8 Size LxHxD mm 360x150x265 Operating voltage switchable 115 230V 50 60 Hz Fuses 230Vac 5x20 TIMED 2x 3 15A Fuses 115Vac 5x20 TIMED 2x 6 3A Five steps adjustable sound level from 55 to 75 dBA e Self check Power accuracy output warning Split or not split patient plate allowed Repetition of timed delivery da2a9 Timed delivery 1 999ms Last working condition storing Electrical Class EN60601 1 I CF MDD 93 42 EEC Class Il b Patient circuit Made in Italy STANDARD ACCESSORIES Two button handle autoc
4. 3 STRAIGHT EU 20cm 73 4 ANGLED GENERAL 1 mm round points Irrigation 30654 BAYONET EU 18cm 7 STRAIGHT GENERAL 1 mm round points 30655 BAYONET EU 20cm 73 4 STRAIGHT GENERAL 1 mm round points UNIVERSAL 30660 STRAIGHT EU 18cm 7 ANGLED GENERAL 0 3 mm points EUROPEAN 30661 STRAIGHT EU 18cm 7 STRAIGHT GENERAL 0 3 mm points CONNECTION Our forceps are 30662 STRAIGHT EU 20cm 73 4 STRAIGHT GENERAL 0 3 mm points P E nei 30665 JEWELER 5 EU 11 5cm 41 2 STRAIGHT OPHTHALMIC MICRO 0 25 mm points European connection 30666 JEWELER 5 EU 11 5cm 41 2 ANGLED OPHTHALMIC MICRO 0 25 mm points enabling their use with GIMA 30667 STRAIGHT EU 15cm 6 STRAIGHT OPHTHALMIC MICRO 0 5 mm points gel i pater 30668 STRAIGHT EU 15cm 6 ANGLED OPHTHALMIC MICRO 0 5 mm points manufacturers 30669 Mc PHERSON EU 10 2cm 4 STRAIGHT OPHTHALMIC MICRO 0 5 mm points E u CONNECTOR BIPOLAR FORCEPS FF l E 30621 SEMKIN 30622 CUSHING 30623 JANSEN BAYONET g rendu Straight ti 0120 Model 2 Application g p 30620 ADSON US 12 1cm 43 4 GENERAL PLASTIC 1 mm round points 30621 SEMKIN US 14cm 51 2 GENERALPLASTIC 0 5 mm points ADSON 30622 CUSHING US 15 9cm 61 4 GENERAL PLASTIC 1 mm round points UNIVERSAL US 30623 JANSEN BAYONET US 17 8cm 7 GENERALPLASTIC 1mm round points CONNECTOR Mm BIPOLAR CABLES FOR MAJOR BRANDS Quality highly flexible silicone bipolar cables Autoclavable at 134 C up to 70 times 3 m long 10 Suitable for most gene
5. LECTRODES 2 4mm Reference GIMA N 13 m code number minimum order 24 pcs number code Length N 11 length 7 cm Sterile electrode length 15 cm 7cm 12 rar ss 30670 13 Needle electrode sterile electrode 33 30674 30671 11 Blade electrode sterile 31 30675 N 34 30672 12 Ball 4mm electrode sterile 32 30676 27 Length Sterile electrode N 33 15cm Loop electrode 15mmx8mm 34 30678 N 32 mM SINGLE USE METAL AND RUBBER PLATES j 30574 rem rubber plate 30562 30565 30567 3055 30566 Adult Adult REM Pediatric disposable Adult pediatric metal plate disposable plate disposable plate plate disposable plate 30573 e 30562 DISPOSABLE GROUND PADS WITH SOLID GEL adult sac plae LOSS Gilman e 30567 DISPOSABLE GROUND PADS WITH SOLID GEL pediatric e 30565 REM DISPOSABLE GROUND PADS WITH SOLID GEL adult 39573 RUBBER PLATE 20x15 cm without cable Adult ground plate with solid gel Single use plate individually packed 30574 REM RUBBER PLATE 20x15 cm without cable e 30563 CABLE FOR PLATES 5 m Universal cable to connect plates 30555 6 30562 30565 6 7 to diatermo e 30575 CABLE FOR RUBBER PLATES e 30566 METAL PLATE without cable Safety lock with universal connection bipolar 6 3 mm plug e 30555 DISPOSABLE NON WOVEN GROUND PADS adult ped 30563 CABLE FOR PLATES 5 m e 30556 REM DISPOSABLE NON WOVEN GROUND PADS adult ped 30559 CABLE FOR PLATES 2 5 m 102 C GIMA
6. Ohm 3 Short general surgery ball electrode 1 User manual Italian English Spanish 0 5 kV 100 Ohm 1 Service manual Italian English French Spanish 0 5 kV 100 Ohm Laparoscopic electrodes SIMA LAPAROSCOPIC ELECTRODES for use with Diatermo code MB 240 250 380 400 30605 L Hook electrode 36 cm with connecting cable 30606 J Hook electrode 36 cm Fm060 30607 Spatula electrode 36 cm 30609 Monopolar cable 4mm M F JD To electrode j gt To generator C GIMA Mm HOSPITAL HF ELECTROSURGICAL UNITS 250 AND 400 WATT ARGON COM PAE EALA i A E 1 J zy mn Ts 2 MONOPOLAR OUTPU PROGRAMME MEMORY ay 121 AUTO START STOP BIPOLAR ATE ah 400 ag g BrT di PROGRAM e 30694 DIATERMO MB 250 e 30696 DIATERMO MB 400 DIATERMO MB250 and MB400 are high frequency electro surgical equipments suitable to deliver current for monopolar cut and coagulated cut with different levels of coagulation bipolar cut and coagulation During bipolar coagulation there is an automatic Autostart Autostop system which activates when coagulation is reached A range of ten different modes and power levels can be easily stored and recalled It is possible to use either single plate neutral electrodes or split conductive zone electrodes in order 9 POLAR I Control of the units is made by front panel keys and display mains inlet is located on the rear panel The unit
7. allow to reduce bleeding during monopolar cut In the bipolar modality the cut can be effected by pure sine current HEMOSTASIS When the surgical action requires the obliteration of a blood vessel the availability of currents with different coagulative powers enables this type of work both with monopolar and bipolar surgery FULGURATION When it is necessary to cause a superficial necrosis of wide areas protecting the deeper tissues a special coagulant current that dehydrates the superficial layer of the tissue and reduces the possibility to damage those beneath is available for the operation OUTPUT CONTROL Output power levels are adjustable through incremental encoders that allow the exact pre sets and repetition of the C Eos fa Go Ea MED A special electronic circuit Skin Plate Electronic Control continuosly warns the plate to patient contact safety and unwanted short circuit in the connec ting cable values The output function is linearized and controlled by ultra modern electronic micro controllers which will interrupt power if any alarm condition happens SAFETY OF USE Circuits dedicated to the safety of operator and patient are the priority This ensure the leakage current is kept well under the values by the international requirements under every output condition Monopolar and bipolar output circuits are completely floating and the use of the defibrillator is allowed while the reference plate pati
8. an intermittent beep together with a flashing red light on the front panel In this case HF emission for cut and coagulation operation is switched off OVT Alarm The unit includes an internal circuit protection warning when the current delivery lasts too much e 27139 DIATERMO NYLON BAG black See page 31 Diatermo MB 122 MB 160 standard accessories MB single use two button handles MB operative foot switch usable as alternative to handle MB flat neutral plate Power cable 2 m Kit of 6 short autoclavable electrodes diam 2 4 mm User manual available in English Spanish Italian French Polish E FOOTSWITCHES AND BOARD ie FOOTSWITCHES FOR MB 122 132 160 200 202 30568 Standard footswitch 2 m cable 30576 Standard footswitch 3 m cable 30571 Waterproof MB footswitch 2m cable 30570 Double MB footswitch antiexplosion water proof FOOTSWITCHES FOR MB 240 250 380 400 30569 Double antiexplosion water proof footswitch MB240 380 30572 Double antiexplosion water proof footswitch MB250 400 MAIN BOARD 30557 Main board specify model and serial number of diatermo with order 30558 Output board for MB 240 250 380 400 specify as above 98 20064 Gorg TECHNICAL SPECIFICATIONS Minimum preselectable power Level step Maximum output power CUT W Maximum output power BLEND W Maximum output power COAG FORCED W Maximum output power COAG SOFT W Maximum output power BIPOLAR W Crest Factor CUT Cres
9. arranty 12 months STANDARD ACCESSORIES KIRKY single use handle without buttons Standard foot switch 30568 Flat neutral plate with cable 30563 Kit of 6 short autoclavable electrodes 2 4 mm length 5 cm Power cable 2 m Shuko plug User manual available in English Italian Spanish French 106 only The modes of operation CUT COAG BLEND and MICRO 30517 only can be easily selected by a switch on the front panel The complete isolation between patient and the unit and strict respect of international norms guarantee total safety 30516 DIATERMO MB 132 MONO BIPOLAR PROGRAMMABLE 120 W OVH Alarm the unit incorporates an internal circuit protection to warn when the current delivery lasts too long DIATERMO MB 132 min I FORCED SOFT cur BLEND COAG COAG BIPOLAR J O P F YYY Programmable POWER SIGIM AS Emission Time Unit e 30544 DIATERMO MB 132 mono bipolar 120 W HF electrosurgical unit suitable to perform middle monopolar or bipolar electrosurgery By selection of the modes of operation MB 132 provides pure cut coagulated cut forced coagulation soft coagulation and with forceps bipolar coagulation The use of either split or normal neutral plate are allowed Technology and precision Using the digital keyboard MB 132 enables the user to regulate the HF emission time in cut or coagulation mode with great precision and to reproduce a previous intervention Moreover it
10. e to perform middle monopolar or bipolar electrosurgery The available waveforms and peak voltage value as well as the accurate HF leakage current operation for polypectomy TURP intrauterine resections endometriosis excision etc The units allow the accurate preset of the output power with as low as 1 Watt resolution and to perform coagulation by high crest factor current to get an elevated thermal effect as well as with low voltage low crest factor current to get coagulation in absence of carbonization Ten different programs related to ten different operative conditions could be stored and easily recalled by the surgeon The use of either split or normal neutral plates are allowed A special electronic circuit Skin Plate Electronic Control continuously checks if the plate is safely connected to the patient and detects unwanted short circuit in the connecting cable An over time warning OVT is provided to prevent excessive heating of the tissue around the surgical target due to too long current delivery time DIATERMO MB202 furthermore can be used with current delivery time equal to that of actuation of the output power switch as well as with preset current delivery time in the range from 1 ms up to 999 ms The output pulse can be automatically repeated 1 to 250 times The presetting of the current delivery time is proper for collecting of bioptic samples and for microsurgical dermatologic operationy like treatment of
11. ent is connected RELIABILITY DIATERMO MB uses all solid state electronic circuits and is made with interchangeable units for a fast and effective maintenance Automatic control circuits protect the units from damage also in case of repeated improper use TECHNICAL SPECIFICATIONS DIATERMO MB 240 DIATERMO MB 380 Activation devices Bipolar footswitch Dual bipolar footswitch Working Max power monopolar manual frequency 240 MB 380 Monopolar footswitch Monopolar output 475 kHz manual Cut output 250W 375W Mains 115 230 Vac 50 60 Hz Cut coag 1 output 225W 340W Absorption 800 VA Cut coag 2 output 200W 300W Class CF Coag 1 output 150W 225W Weight 15 kg Coag 2 output 100W 150W Size 370 x 470 x h 150 mm Coag 3 output spray 80W Warranty 12 months Bipolar output 525 kHz accessories not included Cut output 90W Norms IEC 601 2 2 IEC 601 1 Coag output 80W CE 93 42 EEC m LAPAROSCOPIC ELECTRODES io annette 30605 E 3060 _ E 30607 STANDARD ACCESSORIES 1 Power supply cord SIEM CEE 5 m Peak to peak Load 1 Two button handle autoclavable code 30547 voltage resistance 5 Two button handle cold sterilizable 1 Cable for disposable plate 1 4 kV 300 Ohm 5 Disposable plate 1 4 kV 300 Ohm 1 Water proof double foot switch 1 4 kV 300 Ohm 3 Short general surgery blade electrode 14kV 300 Ohm 3 Long general surgery blade electrode 14kV 300 Ohm 3 Short general surgery needle electrode 42 kV 2000
12. ical Class EN60601 1 MDD 93 42 EEC Class Patient circuit Duty cycle action pause in seconds MB200 0 1 200 2500 200 2500 200 2500 200 2500 120 2000 150 1500 90 1000 100 1000 120 2500 1 5 1 6 1 7 1 8 2 1 2 0 1 7 1 5 1 5 600 kHz 8 360x150x265 115 230 50 60 2x 3 15A 2x 6 3A I CF Il b 10 30 200 2500 200 2500 200 2500 200 2500 120 2000 150 I500 100 1000 100 1000 600 kHz 8 360x150x265 115 230 50 60 2x 3 15A 2x 6 3A o o 1 999ms CF Il b 10 30 99 HOSPITAL HF ELECTROSURGICAL UNITS 240 AND 380 WATT Jf DIATERMO MB 240 mont a Dua PEDAL AORO MANUAL Skin Plate Electronic Control CONTEMPORARY DUAL MODE MB 240 and 380 can be used in the same time in monopolar mode by handle and bipolar mode by footswitch 30690 e 30690 DIATERMO MB 240 e 30692 DIATERMO MB 380 nae These HF electrosurgical units can be used to execute monopolar and bipolar surgery when high precision and reliability are essential as in the endoscopic surgery EASY TO USE Graphic icons allow an easy selection of the operation mode All operating conditions and selected output controls are represented by bright digital indications CUT The monopolar cut can be performed by pure sine current to obtain an incision with a minimum damage for the adjacent tissues and sure recovery for first intention Two different modalities of modulation
13. lavable code 30547 MB operative foot switch usable in alternative to handle MB flat plate neutral electrode Kit 10 short standard electrodes diam 2 4 mm Power cable 2 m Microsurgery handle Microsurgery needle Manual available in English Italian Spanish French 97 B DIATERMO MB 122 AND MB 160 MONO BIPOLAR 120 w 160W EXCLUSIVELY MANUFACTURED FOR pA e 30540 DIATERMO MB 122 mono bipolar 120 W e 30541 DIATERMO MB 160 mono bipolar 160 W MB 122 and 160 are HF electrosurgical units suitable to perform middle monopolar or bipolar electrosurgery By selection of the modes of operation they provide pure cut coagulated cut forced coagulation soft coagulation and with forceps bipolar coagulation The use of either split or normal neutral plate is allowed MB 160 is recommended in case of operational fields damp for instance mucous or tissue whose composition is varying with consequent need to have reserve of usable power For these reasons MB 160 is suggested for Gynecological and orthopedic surgery Leading Edge Technology This advanced concept device enables highly professional surgery intervention thanks to ergonomic and safety features derived from high power theatre apparatus Complete safety Open Circuit OC Alarm warns the user that connection into the neutral plate has not been made or that the cable is disconnected or the neutral plate is not in contact with the patient The alarm is signalled by
14. of a needle into the follicle of the hair Provided with highly reliable electronic integrated components with RF intensity adjustable with continuity and luminous working signal It comes complete with footswitch handpiece for depilation depilation needle ano panar cable 2 m z rt Ie sy C GIMA MONOPOLAR Elat AASE UNITS 50W AND 80W 4 r ra r Footswitch operating e 30516 DIATERMO 106 50W monopolar e 30517 DIATERMO 108 80W monopolar These HF electrosurgery units are particularly suitable for small operations and are recommended for veterinary dentistry first aid and dermatology work They offer precision of cut and immediate coagulation and give excellent results in a large range of applications from uterine coagulation to microcoagulation in dermatology Moreover you can choose from a wide variety of electrodes for any need aia 0051 bil nee GAC TECHNICAL SPECIFICATIONS 30516 106 Output power CUT 50W 400 ohm COAG 40VW 400 ohm BLEND 45W 400 ohm 30517 108 80W 400 ohm 50W 400 ohm 60W 400 ohm MICRO 20W 600 ohm Working frequency 600 KHz 10 700 KHz 10 Size 180x180x h 100 mm 180x180x h 100 mm Weight 2 8 kg 4kg Operating Voltage 115 230 V 50 60 Hz switchable Electric input power 90 VA 230 VA Fuse 2x1 AT 2x2 A Alarm for overheating Footswitch operating Norms EN60601 1Class CF EN 60601 1 2 93 42 EEC Class IIb Made in Italy W
15. ower VA 800 1000 Self check Patient circuit F Defibrillation proof Equipotential binding Metallic cabinet MONOPOLAR AND BIPOLAR APPLICATION DIATERMO MB 250 AND MB 400 Working Max Power imped Maximum Frequency MB250 400 output voltage Monopolar Applications 425 kHz Cut 250 400 W 3000 1500 Vpp Cut Coag 80 220 300 W 3000 1500 Vpp Cut Coag 60 200 250 W 3000 1500 Vpp Cut Coag 40 150 200 W300 1500 Vpp Enhanced Cut 150 250 W 3000 1500 Vpp Blend 150 250 WS 500 2500 Vpp Speedy Coag 100 120 W500 2500 Vpp Deep Coag 100 120 W 5009 800 Vpp Spray Coag 60 100 W 20000 4500 Vpp Spray Coag Argon 60 100 W 20000 4500 Vpp Bipolar Applications 525 kHz Bipolar Cut 120 W 150 O 800 Vpp Bipolar Cut Coag 80 100 W 150 Q 800 Vpp Bipolar Cut Coag 60 100 W 150 Q 800 Vpp Bipolar Cut Coag 40 60 W 150 QO 800 Vpp Bipolar Blend 100 W 300 Q 1100 Vpp Bipolar Deep Coag 70 W 100 Q 400 Vpp Electrical input current 230Vac A 3 5 4 5 Electrical input current 115Vac A 7 9 Five steps adjustable sound level Power accuracy output warning Skin Plate Electronic Control plate patient control Split or not split patient plate allowed Working condition storing last 10 setup Electrical Class EN60601 1 ICF MDD 93 42 EEC Class II b EN55011 CISPR 1 1 Class Class Group 2 B Ten seconds delivery warning OVT Polycarbonate covered panels Conform to EN60601 1 1998 Conform to EN6060 1 1 2 2003 Conform to EN6060 1 2 2 2000 func
16. pth code number autoclavable at120 C length width depth 30680 41 Loop electrode 8 mm 11cm 8mm 8mm 30686 50 Square loop electrode 13cm 10mm 8mm 30682 42 Loop electrode 15mm 11cm 15mm 15mm 30687 51 Loop electrode 13cm 15mm 8mm 30683 43 Loop electrode 20 mm 11cm 20mm 15mm 30688 52 Loop electrode 13cm 20mm 10mm mM AUTOCLAVABLE ELECTRODES GIMA Reference code number length 5 cm minimum order 6 pcs length 10 cm Reference GIMA number code 15 16 17 AUTOCLAVABLE ELECTRODES 2 4mm 30501 1 Electrode wire straight 21 30521 1 2 3 4 gt 6 7 8 9 10 J Pi 30502 2 Electrode wire angled 45 22 30522 5 cm o electrodes reference number 30503 3 Electrode bend 4 straight 23 30523 a 30504 4 Electrode bend 8 straight 24 30524 30505 5 Electrode hook angled 45 25 30525 30506 6 Electrode wire 1 mm angled 45 26 30526 30507 7 Electrode straight slip knot straight 27 30527 30508 8 Electrode angled slip knot straight 28 30528 30509 9 Electrode ball point 3mm angled45 29 30529 ry 4 me w 30510 10 Electrode ball point 3 mm straight 30 30530 30500 SET Set of 10 electrodes SET 30531 rr i ee i ie length 7 cm minimum order 10 pcs length 15 cm cm long electrodes rererence number cm 30511 15 Needle electrode 35 30532 21 22 23 24 25 26 27 28 29 30 35 36 37 30512 16 Blade electrode 36 30533 AUTOCLAVABLE AUTOCLAVABLE 30513 17 Ball electrode 37 30534 100 TIMES 20 TIMES GIMA Reference SINGLE USE E
17. rators see below compatibility and with connector for European or US forceps yr 30639 30638 GIMA code 30640 30637 30643 Connector to forceps m EU US EU EU MH EU Connector to electrosurgical unit 4 mm banana plug GIMA MB122 MARTIN ERBE check beside compatibility GIMA MB240 250 380 400 MB160 BERTHOLD SELECT list for brand and model VALLEY LAB MB132 AESCULAP DOWN CONMED CODMAN MB200 WOLF SIEMENS OLYMPUS MB202 104
18. ro depilators ELECTRODE BRUSH E MONOPOLAR FORCEPS SCISSORS AND CABLES monopolar cables C 0120 units in the market GIMA code INSULATED MONOPOLAR INSTRUMENTS 30610 Monopolar cable 4mm pin Metzenbaum 30611 Mc INDOE straight monopolar forceps 15 cm 6 30612 Bayonet monopolar forceps 19 cm 71 2 30613 Monopolar scissors 18 cm 7 a See 30614 Metzenbaum monopolar scissors straight 18 cm 7 a 30615 Metzenbaum monopolar scissors curved 18 cm 7 103 E UNIVERSAL HIGH QUALITY INSULATED BIPOLAR FORCEPS 30667 General forceps Ophthalmic Micro forceps ee MC PHERSON 30669 a Binner electrodes for ENT application ador 30654 Bayonet forceps 0120 JEWELER 30665 EEEE Angled tip wee ISO 9001 FDA Approved J ISO 13485 JEWELER 30666 GIMA Length ye pane Model E Tip style Application Tip size Straight tip 30645 BINNER EU 22cm 81 2 ANGLED ENT 30646 BINNER EU 18cm 7 STRAIGHT ENT 30647 BINNER EU 18cm 7 ANGLED ENT 30648 BINNER EU 19cm 73 8 ANGLED 45 ENT EOT 30650 STRAIGHT EU 18cm 7 STRAIGHT GENERAL 1 mm round points 30656 STRAIGHT with irrigation EU 18cm 7 STRAIGHT GENERAL 1 mm round points 30651 STRAIGHT EU 20cm 73 4 STRAIGHT GENERAL 1 mm round points 30658 STRAIGHT EU 20cm 73 4 STRAIGHT GENERAL 2 mm round points 30656 30652 STRAIGHT EU 18cm 7 ANGLED GENERAL 1 mm round points 3065
19. s have automatic control systems to monitor the internal parameters and alert on possible damages errors The operational parameters used are constantly stored so that the last selected parameters are recalled every time the unit is switched on or the operative method is changed The level of sound can be adjusted every operator can choose his own level according to the environmental working conditions The units can work through handles with pushbuttons or handles without pushbuttons but with double foot switch It s to control impedance stability of plate to patient contact during possible to connect bipolar forceps to the unit for the bipolar the surgical operation TECHNICAL SPECIFICATIONS MB250 MB400 Work condition memorization Digital power visualization Continuous check control Automatic control of the plate patient connection Automatic control of the impedance Automatic control of excessive time for distribution Automatic control of the supplied power level Bipolar coag with automatic activation disact Consistent with Argon unit Minimum preselectable power 0 Unitary power step for powers from 0 W to 50 W Power step 10 for powers higher than 50 W Digital level display Selection of power through push buttons Size LxHxP mm 470 x 150 x 380 Weight kg 18 Selectable mains power Vac 115 230 Mains frequency Hz 50 60 Fuses 230Vac 5x20 TIMED 2xT 4A 5A Fuses 115Vac 5x20 TIMED 2xT 8A 10A Electrical input p
20. t Factor BLEND Crest Factor COAG FORCED Crest Factor COAG SOFT Crest Factor BIPOLAR Working frequency Weight Kg Size LxHxD mm Operating voltage switchable Mains frequency Hz Fuses 230Vac 5x20 TIMED Fuses 115Vac 5x20 TIMED Electrical input power VA Electrical input current 230Vac A Electrical input current 115Vac A Five steps adjustable sound level from 55 to 75dBA Self check Power accuracy output warning Split or not split patient plate allowed Last working condition storing Electrical Class EN60601 1 MDD 93 42 EEC Class Patient circuit Conform to EN60601 1 4 1998 Antiexplosion and waterproof MB122 0 1 120 90 80 60 40 15 2 1 2 0 1 7 1 5 2500 2000 1500 1000 1000 600 kHz 7 260x110x265 115 230 50 60 2x 3 15A 2x 6 3A 300 1 3 2 6 30569 gt a MADE IN ITALY MB160 0 1 160 120 100 80 60 1 5 2 1 2 0 1 7 15 2500 2000 I500 1000 1000 600 kHz 7 260x110x265 115 230 50 60 2x 3 15A 2x 6 3A 350 1 5 o gt W oQ eal It allows selection from pedal of CUT and COAG functions GIMA DIATERMO MB 200 AND MB 202 MONO BIPOLAR 200 w PDIATERMO MB m TUT muiaat Par Bigi Cu a l i e Skin Plate Electronic Control e 30542 DIATERMO MB 200 200 Watt e 30546 DIATERMO MB 202 200 Watt DIATERMO MB200 and MB202 are HF electrosurgical units suitabl
21. t with a 5 meters long silicone cable only guarantees a safe contact but also adapts to the different Single use handle with click push buttons for cut and coag Same as 30551 minimum order 10 pcs C i k ee ae 30519 autoclavable Gima Diatermo and majority of electrosurgical units in the market a 3 meters long cable and a blade electrode with 4 mm PIN connection minimum order 10 pcs e 30552 MICROSURGERY HANDLE e 30537 ELECTRODE BRUSH 50x50 mm Monopolar forceps are provided 30612 tip 2mm FDA These can be used with all Gima Led e 30547 ORION AUTOCLAVABLE HANDLE 100 times electrode diameters Includes blade electrode minimum order 10 pcs These handles do not have push buttons al e 30519 AUTOCLAVABLE 106 108 HANDLE C 0086 It can be autoclaved up to 50 times Ji e 30518 KIRKY SINGLE USE 106 108 HANDLE STERILE E A AT e 30560 MICROSURGERY NEEDLE Disposable sterile radiopaque abrasive tip cleaner pad Box of 100 with a 4 mm connection for standard AREROVED Erbe and many other electrosurgical Same as 30554 but with a screw clamp locking system that not e 30551 KIRKY SINGLE USE HANDLE STERILE e 30553 GIMA SINGLE USE HANDLE STERILE 1406 HANDLES These handles are provided with a 1 Pin socket 4 mm that fits all Autoclavable handle without buttons provided with 30518 single use Single use handle without button with blade electrode Microsurgery accessories for all GIMA Diatermo and elect
22. telangiectasias spider nevus angiomas etc Bipolar cable and forceps are not included in standard accessories DIATERMO MB 200 MB 202 STANDARD ACCESSORIES MB two button handle autoclavable code 30547 handle in beside picture is not correct MB operative foot switch usable in alternative to handle MB flat neutral metal plate with cable Kit 9 short standard electrodes diam 2 4 mm Power cable 2 m Microsurgery handle Microsurgery needle 10 pcs only MB 202 Manual available in English Italian French only MB 202 TECHNICAL SPECIFICATIONS Minimum preselectable power Level step digital Maximum output power CUT W Maximum output power CUT 90 W Maximum output power CUT 80 W Maximum output power CUT 70 W Maximum output power BLEND W Maximum output power COAG FORCED W Maximum output power COAG SOFT W Maximum output power BIPOLAR W Maximum output power BIPOLAR COAG W Maximum output power BIPOLAR CUT W Crest Factor CUT Crest Factor CUT 90 Crest Factor CUT 80 Crest Factor CUT 70 Crest Factor BLEND Crest Factor COAG FORCED Crest Factor COAG SOFT Crest Factor BIPOLAR Crest Factor BIPOLAR CUT W Crest Factor BIPOLAR CUT W Working frequency Weight Kg Size LxHxD mm Selectable mains power Vac Mains frequency Hz Fuses 230Vac 5x20 TIMED Fuses 115Vac 5x20 TIMED Power accuracy output warning system Split or not split patient plate allowed Timed delivery repetition Electr
23. tery operated disposable device C ose for the cauterization of small vessels the temperature of the tip is 1 200 C With a fine tip required in most of the surgeries e 30582 GYNAECOLOGY CAUTERY 1 200 C fine tip Same as 30580 but with the tip fixed on a shaft 12 cm long e 30581 ELECTROCAUTERY 600 C fine tip Same as 30580 but with lower temperature 600 C 230580 PONCE Ieee Expecially designed for ophthalmology n battery 60 min e 30583 EMERGENCY ELECTROCAUTERY 800 C Thick tip x pe aaa A Same as 30580 but with thick tip that permits the perforation of nails in case of haematoma Weight 65 g length 18 cm E HISTOFREEZER cRYOTHERAPEUTIC AID e 30585 HISTOFREEZER mini kit One 40 ml aerosol bottle 2 applicators 2 mm and 3 applicators 5 mm e 30587 HISTOFREEZER kit 2 mm One 150 ml aerosol bottle and 60 applicators 2 mm e 30588 HISTOFREEZER kit 5 mm One 150 ml aerosol bottle and 50 applicators 5 mm C eee m ELECTRODEPILATOR Syste ryt rtatif Draagbaar fgets as Wistoit lt lt RAAQY LAA SVs a SS NS ANNAN oY Si 3 LES e 28340 ELECTRO DEPILATOR 400 e 30552 HANDPIECE FOR DEPILATION This device ensures a definitive depilation with thermolitic e 30560 DEPILATION OR MICROSURGERY NEEDLES method It delivers a current of radiofrequency to cause the e 30568 FOOTSWITCH heating and consequent coagulation of the papilla reached through the introduction
24. tions Ventilation grille Wide Dissipative Sound level s rface RS 232 interface Voltage selector Connection Equipotential for enslaved Connection plug for enslaved Argon Plasma unity S external unity Duty Cycle action pause in seconds 10 30 Output power control by foot switch or finger switch STANDARD ACCESSORIES 1 Power supply cord SIEM CEE 5 m 1 Two button handle autoclavable code 30547 5 Two button handle cold sterilizable 1 Cable for disposable plate 5 Disposable plate 2 HP double Water proof foot switch 3 Short general surgery blade electrode 7 cm 3 Long general surgery blade electrode 10 cm 3 Short general surgery needle electrode 5 5 cm Modulation Duty Crest 3 Short general surgery ball electrode 4 mm 6 cm factor Cycle Factor A E 1 User manual Italian English 1 6 1 Service manual Italian English 10 kHz 80 1 8 10 kHz 60 2 1 10 kHz 40 2 6 1 25 kHz 5 1 6 1 6 8 12 kHz 20 3 4 1 6 1 kHz 20 3 4 1 kHz 3 4 1 5 10 kHz 80 1 7 E 10 kHz 60 2 0 10 kHz 40 2 4 17 ea 15 _ Standard accessories 101 m LOOP COLPOSCOPY AUTOCLAVABLE ELECTRODES N 41 a i N 50 C 0120 Electrode section 0 2 mm tungsten wire GIMA Reference COLPOSCOPY ELECTRODES Shaft Electrode Electrode GIMA Reference LOOP ELECTRODES 2 4mm Shaft Electrode Electrode code number 2 4 mMM autoclavable at 120 C length width de

Download Pdf Manuals