1. Off in the Set mode line The following picture will appear in the General page SCENARIOS Control unit mode Manual 15 Season Summer LIGHTING AUTOMATISM Refresh State HOUSEHOLD APPLIANCE w e e ALARM S Temperature Measured Temperature Expected Knob Mode Fan coil CCTV ANSWERING SYSTEM Sis TEMPERATURE CONTROL H3 8 GENERAL PROGRAMMING DIAGNOSTIC The signalling of the zone in Off mode will be given on the Web pages and on the Control unit with the L icon Diagnostics WebServerAVConfig SCENARIOS P The control unit does not respond AUTOMATISM HOUSEHOLD APPLIANCE ALARM ccTv Y ES EES ANSWERING SYSTEM E THERMOREGULATION 3 GENERAL PROGRAMMING On the Diagnostic Web page a check can be made of the devices in the individual zones and if there is a fault on one or more zones of the system the anomaly can be signalled The following mes sages can be displayed e No anomaly found when the system works correctly e Problem on the system when there is a problem in one or more zones sensors followed by the list of zones where there is a fault and its description e The control unit does not respond when the bus connection is interrupted there is no power supply on the system or no sensor zone manages to communicate with the WebServerAVConfig Signalling faults via e mail The WebServerAVConfig
2. a degree e antifrost thermal protection in which the temperatures are fixed at 7 C antifrost or 35 C thermal protection e automatic to return the zone selected to the operation set on the control unit when this zone has not been forced to different operation e OFF in which the system can be switched OFF Zone Programming a ES D Automatic Set Mode Set Temperature C Fan coll Unlock room sensor settings CENTRAL UNIT ZONES The settings of the individual zones sensor can be unlocked and then reactivated whenever they are locally set in OFF or antifrost thermal protection Its operation will be put to that set on the control unit For any programming to be accepted it must be followed by pressing the M key on the right of the chosen program The message command sent is given in response To check remotely whether the control unit has received and accepted the command go to the General page and check that the control unit and or the programmed zone has modified its state 2 22 Web Server The Manual mode is activated in the Programming Zones page by selecting the zone to be modified in the Set mode pull down menu and Manual in the Set mode line and entering the temperature value required The zone chosen will remain at this temperature until this mode is modified remotely or in the control unit The following picture will appear
3. Automatic v Activate Menu Temp Control The settings of the individual zone sensor can be unlocked and then reactivated whenever they are locally set in OFF or antifrost thermal protection Its operation will be put to that set on the Control unit For any programming to be accepted it must be followed by pressing the XX key on the right of the chosen program The message command sent is given in response To check remotely whether the control unit has received and accepted the command go to the Zone State page and check that the control unit and or the programmed zone has modified its state The Manual mode is activated in the Control unit Programming page by selecting the zone to be modified in the pull down menu and Manual in the Set mode menu and entering the temperature value required The zone chosen will remain at this temperature until this mode is modified remotely or in the control unit The following picture will appear in the Zone State page Di legrand Temp Control a Fone 1 Temperature A eal Temperature 97 Expected Knob 3 Mode Manual Fan coil Menu Temp Control The signalling of the zone in Manual mode will be given on the Control unit State Web pages and on the Control unit with the icon 41 42 Web Server EI III The Antifrost Thermal Protection mode is activated in the Zone Programming page by sele
4. Bluetooth Attention configure the Operation guaranteed with Handhelds with Windows Mobile Windows CE 2002 or higher operating WebServerAVConfig with the system Correct operation is not guaranteed with Palm OS TiWebServerAVConfig program Web Server SSS EEE 1 Use of the MH2 with Web pages from Personal computer The interaction with the In One by Legrand systems connected to the WebServerAVConfig can occur locally on LAN or Wi Fi network and remotely accessing them with public Internet address or via modem through Web pages where the types of action to be performed and the control pushbuttons have already been configured and customised With connection via modem local telephone line the user must configure the Remote Access function on the control PC for more information see Guide to the configuration of the Networks and the PC When the browser has been started the numerical address or URL Uniform Resource Locator standard method for indicating the logic address of a specific network resource e g 192 168 1 35 of the WebServerAVConfig which the program must connect to set up a direct connection line to the In One by Legrand system must be indicated The connection and the data exchanged with the site are protected In One by Legrand uses the SSL 128 bit encryption system based on the Secure Sockets Layer protocol All the application pages are downloaded using this protocol which guarantees
5. Problem on the system when there is a problem in one or more zones sensors followed by the list of zones where there is a fault and its description e The control unit does not respond when the bus connection is interrupted there is no power supply on the system or no sensor zone manages to communicate with the WebServerAVConfig H legrand Temp Control No anomaly found Refresh State Menu Temp Control To end a connection with the WebServerAVConfig session before closing the navigation browser click on the EXIT pushbutton 43 44 Web Server E 6 Examples of ways 6 1 Home with local area network LAN of connection to the If the Personal Computer is already connected to the network connect by entering the WebServer WebServerAVConfig AVConfig IP address in the Internet Explorer navigation bar At this point to access the In One by Legrand function control page enter the name and password in the user identification home page E Cy i Access Point ethernet In One by Legrand LAN network systems BUS ce CR CR GIES lt lt lt 6 2 Home with ADSL subscription with fixed IP From a PC connected to the Internet the connection is made by entering your IP address in the Internet Explorer navigation bar check that the Wi Fi Router Modem is correctly configured At this point to access the In One by Legrand function control page
6. setting Timing selection Display light ON OFF Flash frequency state commands selection State request Confirmation pushbutton message The confirmation message Command sent is displayed in the page for each command sent suc cessfully Web Server E 2 3 Automatisms In managing the AUTOMATISMS function the Web page displays the pushbuttons for sending the UP DOWN STOP and State request command WebServerAVConfig SCENARIOS E HOUSEHOLD APPLIANCE gt oO p a al o LIGHTING ALARM CCTV ANSWERING SYSTEM D THERMOREGULATION a The confirmation message Command sent is displayed in the page for each command sent suc cessfully Web Server 2 4 Alarms When the ALARMS function is selected the Web page displays the burglar alarm system state with a text When there is an alarm the message indicates the type of alarm e g intrusion alarm tampering alarm or technical alarm and where it came from e g living room WebServerAVConfig SCENARIOS Alarms condition LIGHTING No alarm activated AUTOMATISM HOUSEHOLD APPLIANCE ccTv ANSWERING SYSTEM THERMOREGULATION be If there are no alarm events the message No alarm activated If there is an alarm event the message anti intrusion alarm lt zone name gt where lt zone name gt is the name of the zone where the intrusion event occurred It can be cust omised with the TiWebServerAVConfig program Si
7. Using the TiWebServerAVConfig program the WebServerAVConfig can be configured so that the AN SWERING MACHINE function can also be activated by pressing aln One by Legrand Automations system control push button and or switching on the burglar alarm Also when the ANSWERING MACHINE has been activated the WebServerAVConfig can activate a signal light by means of Automation system devices The installer must set up the Automation system to perform the functions described above Pictures saved The number can be configured by the Web page or by the TiWebServerAVConfig program WebServerAVConfig SCENARIOS Messages present uere coe oe fs AUTOMATISM APPLIANCE ar ALARM cctv WebServerAVConfig ANSWERING SYSTEM By E EEE THERMOREGULATION j y Ca oal ra on x a vet ALARM cerv ANSWERING SYSTEM Cy THERMOREGULATION Memory used 5 ieee 2 Answering system activated e E N d Deactivate Picture selected for display to return to displaying all the pictures recorded select the message to be heard again Detail of the pushbuttons and the actions performed cere Activate deactivate answering system OD Listen to message Deactivate pushbutton a Cancel message Date 09 02 09 OEE ae g hou SA Message date and time indication Indication in of the mem Memory used O OO gt ised Web Server E 2 8 Thermoregulation When the TEMPERATURE CONTROL function is selected the web
8. date and time of the recorded message the percentage of memory used by the WebServerAVConfig for the messages and showing the ON OFF pushbutton of the answering system itself Oi legrand Answering System Memory used 5 Activate Menu Clicking on the date time of the recorded message a window opens showing the photograph of the person who left the message The various photographs taken when the recording was made are available under the picture and can be selected by just clicking on the picture number The number of pictures taken and saved can be configured with the TiWebServerAVConfig program or accessing the WebServerAVConfig with the PC Web pages 33 Web Server G E D legrand Answering System d 1234 Menu nswering System Menu The user can configure the answering system service with the TiWebServerAVConfig program or by means of the Web pages as administrator user from Personal Computer by selecting CONFIGURATION With the TiWebServerAVConfig program the WebServerAVConfig can be configured so that the ANSWERING SYSTEM function can also be activated by pressing a In One by Legrand Automation system control pushbutton and or switching the Burglar Alarm ON Moreover when the ANSWERING SYSTEM is activated the WebServerAVConfig can activate a light signal via Automation system devices The installer must set up the Automation system for the functions described above To display another message pr
9. enter the name and password in the user identification home page harira ethernet In One by Legrand systems BUS Telephone line ISP Internet Web Server 7 Troubleshooting General checks on switching ON after connection e When the power supply is connected the LED turns on off and then on again confirming that the web server is working If this does not happen contact the technical after sales service 7 1 The WebServerAVConfig does not respond to requests via Ethernet browser ping etc e Check that the power supply cable is connected e Check that the video door entry system is correctly connected and working e Check that the PC Ethernet cable used to communicate with the WebServerAVConfig and the WebServerAVConfig cable are correctly connected to their RJ45 ports e Check that the PC used to communicate with the WebServerAVConfig and the WebServerAVConfig are correctly configured in particular check that the PC network interface is active and that its IP address and netmask are compatible with those of the device e Also check that the IP addresses set in the PC and the WebServerAVConfig are not already being used by other devices in the LAN 7 2 The WebServerAVConfig does not send e mail e Make sure that the settings for the SMTP to be contacted to send e mail entered in TiWebServer AVConfig are correct e Check with at least one other elec
10. in the General page SCENARIOS Control unit mode Weeki Program 1 Season Summer LIGHTING Refresh State Temperature Measured 28 Temperature Expected 16 Knob 1 Mode Manual Fan coil AUTOMATISM HOUSEHOLD APPLIANCE ALARM CCTV SNe e ee ANSWERING SYSTEM TEMPERATURE CONTROL GENERAL PROGRAMMING DIAGNOSTIC The signalling of the zone in Manual mode will be given on the Web pages and on the Control unit with the M icon The Antifrost Thermal Protection mode is activated in the Programming Zones page selecting the zone to be modified in the pull down menu and Antifrost in the Set mode line if the system is in win ter mode season and Thermal device protection if the system is in summer mode season The following picture will appear in the General page SCENARIOS Control unit mode Manual 15 Season Summer Refresh State LIGHTING AUTOMATISM HOUSEHOLD APPLIANCE ALARM Temperature Measured Temperature Expected Knob Mode Fan coil CCTV ANSWERING SYSTEM SRST SEIS a TEMPERATURE CONTROL Ey GENERAL PROGRAMMING DIAGNOSTIC The signalling of the zone in Antifrost mode will be given on the Web pages and on the Control unit with the E amp J icon Web Server E The Off mode is activated in the Programming Zones page selecting the zone to be modified in the pull down menu and
11. item 03551 of the Automation system D legrand Scenarios Day HE Night Ki Cinema T Menu The confirmation message Command sent is displayed for each command sent successfully If the command was not successful the Command not sent message is displayed To activate another function press the Menu pushbutton to return to the main menu 5 2 Lighting In managing the LIGHTING function the Web page displays the pushbuttons for sending the ON OFF command D legrand Lighting Kitchen Ihol Living Room DE Bedroom oc Garden og Refresh Menu The confirmation message Command sent is displayed for each command sent successfully If the command was not successful the Command not sent message is displayed The state of the lights can be requested by pressing the Update key A box where the state of the lights is signalled appears by the side of the light points e ON light ON e OFF light OFF The state of the lights cannot be displayed for the general commands the rooms and the units For double commands for the same light point e g LIVING ROOM LIGHT ON and LIVING ROOM LIGHT OFF the light state is only displayed for the first of the two To activate another function press the Menu pushbutton to return to the main menu Web Server E The light points shown in red indicate the presence of a submenu to adjust the Timing and Flashing commands and control the dimmer Access the submenu by clicking on
12. page displays three pushbuttons CONTROL UNIT NON CONTROLLED ZONES EXTERNAL SENSORS WebServerAVConfig SCENARIOS o gt LIGHTING AUTOMATISM HOUSEHOLD fg APPLIANCE is ALARM Hey UNCONTROLLED ZONES ba CENTRAL UNIT cv a ANSWERING SYSTEM EXTERNAL PROBES THERMOREGULATION q e cf Al ia Control unit When CONTROL UNIT is selected the web screen displays three areas General Programming and Diagnostic The first is for checking the system status the second for setting the system parameters and the third to perform a system diagnostic SCENARIOS Control unit mode Control unit with 4 zones 1 Manual 16 LIGHTING Season Summer AUTOMATISM Refresh State HOUSEHOLD APPLIANCE ALARM Temperature Measured Temperature Expected Knob Mode Fan coil ccTvV ANSWERING SYSTEM TEMPERATURE CONTROL Jeanas N GENERAL PROGRAMMING DIAGNOSTIC The General Web page is divided into two areas which before they are displayed are interrogated by proposing the system interrogation in progress message The state of the thermoregulation system is summarised in the upper part supplying information similar to that which can be read on the control unit display The individual system zones or all of them can be interrogated in the low part Web Server E as e The update state text Press on this to ask the control unit to up
13. pages Control unit and Zones The parameters for the control unit are set in the Control unit page in the seven modes provided e weekly in which you can select a week program configured with the TiWebServerAVConfig software or the last program selected e scenarios in which you can select a scenario configured with TiWebServerAVConfig or the last program selected e weekend in which a weekend day can be activated up to the time chosen The time set must be later than the current time and if no time is set the command is not sent e holiday in which the holiday can be activated with ending date and time e manual in which temperatures can be set between 5 and 39 5 C with deviation of half a de gree e antifrost thermal protection in which the temperatures are fixed at 7 C antifrost or 35 C ther mal protection e OFF in which the system can be switched OFF 20 Web Server For any programming to be accepted it must be followed by pressing the M key on the right of the chosen program The message command sent is given in response To check remotely whether the control unit has received and accepted the command go to the General page and check that the control unit and or the programmed zone has modified its state If the system is in winter mode season in selecting the programs scenarios only the winter ones appear and the antifrost mode appears Vice versa if the system is in su
14. there are no alarms No alarm activated is displayed If there is an intrusion Intrusion alarm lt zone name gt is displayed If there is a tampering alarm tamptest Tampering alarm is displayed If there is a technical alarm Auxiliary alarm lt alarm name gt is displayed Press the Refresh Update pushbutton to check the state of the intrusion system and its alarms To activate another function press the Menu pushbutton to return to the main menu Web Server E 5 5 CCTV When CCTV is selected the Web page displays the picture sent by one of the 4 cameras black and white or colour in the CCTV system connected to the WebServerAVConfig The picture displayed on the handheld is always in black and white Using colour cameras the picture quality may not be quite as good O legrand CCTV Camera e Activate Disattiva Refresh Time 2 Seconds Activate The camera to be displayed is selected by means of the pull down menu and then pressing the Activate pushbutton by the side of the camera name To modify the picture frame rate number of pictures displayed in a second in the Refresh Time part select the time required in the pull down menu and press on the Activate pushbutton 5 6 Answering system When the ANSWERING SYSTEM function is selected the Web page displays whether there are any messages in the video door entry system answering system displaying the
15. AHHH nmi April 09 PC Ll legrand Web Server Index Description of the WebServerAVCON AIG csssssssssssssssssssssssssnssssunsnsesssssssssseseeeceesssssssssssasnsssnueesses 4 1 Use of the MH2 with Web pages from Personal computer 6 2 Pae TUN CUI OUNS cise pect lessen asec eer eee 9 2 1 Scenarios 9 2 2 Lighting 10 2 3 Automatisms 11 24 Alarms 12 2 5 CCTV 13 2 6 Answering system lo 2 8 Thermoregulation 16 3 Functions reserved for the administrator user 25 3 1 Configuration System 25 3 2 Configuration Language 2r 3 3 Configuration Answering system 27 4 Use of the WebServerAVConfig with Web Pages from handheld computer 29 5 Managing the FUNCTIONS 0 ccccccccccccsssssssssssssesssssssssssssssssssssesseseseesssssssnsnsesesseeeeessssssssnsesesseseeeestssssssen 30 5 1 Scenarios 30 5 2 Lighting 30 5 3 Automation 31 5 4 Alarms 32 59 CETV 33 5 6 Answering system Ja 5 7 Thermoregulation 34 6 Examples of ways of connection to the WebServerAVCON ig ccccccssssssssssseseees 44 6 1 Home with local area network LAN 44 6 2 Home with ADSL subscription with fixed IP 44 7 TOUDICSHOOUING a ais cerrtermnennny arian aieann A Giese ani 45 7 1 The WebServerAVConfig does not respond to requests via Ethernet browser ping etc 45 7 2 TheWebServerAVConfig does not send e mail 45 7 3 TheWebServerAVConfig does not perform the commands sent to the In One by Legrand systems 45 Web Server EII De
16. MATISM Refresh State HOUSEHOLD APPLIANCE All the zones ALARM CCTV SESS EIS ANSWERING SYSTEM E TEMPERATURE CONTROL 2 GENERAL PROGRAMMING DIAGNOSTIC The signalling of all the zones in Holiday mode will be given on the Web pages and on the Control unit with the wording Holiday and the number of days in which this state will be maintained with the addition of the icon Web Server The Manual mode is activated in the Programming Control unit page by selecting Manual in the Set mode pull down menu and setting the temperature value required The system will keep all the zones at this temperature until this mode is modified remotely or in the control unit The following picture will appear in the General page SCENARIOS LIGHTING AUTOMATISM HOUSEHOLD APPLIANCE ALARM CCTV ANSWERING SYSTEM TEMPERATURE CONTROL Control unit mode Manual 15 Season Summer Refresh State All the zones Knob Mode 1 Manual lo n 8 S OFF Local Manual 7 amp GENERAL PROGRAMMING DIAGNOSTIC The signalling of all the zones in Manual mode will be given on the Web pages and on the Control unit with the wording Manual and the temperature value set with no other icon The parameters for the individual zones are set in the Zones page e manual in which temperatures can be set between 5 and 39 5 C with deviation of half
17. THERMOREGULATION CONFIGURATION lo ie b LANGUAGE ANSWERING SYSTEM To confirm the entered data press the amp pushbutton 29 26 Web Server EII ss On clicking on DIAGNOSTIC the page containing the device parameters and the diagnostic message e g No anomaly found is displayed WebServerAVConfig SCENARIOS DEVICE PARAMETERS 573992 Normal 0d1h34m 38 LIGHTING AUTOMATISM FW Version HW Version Micro Version Mac Address Kernel Version HOUSEHOLD APPLIANCE Refresh ALARM DEVICE DIAGNOSTIC HW Fault SCS fault DATE TIME ccTv CONFIGURATION DIAGNOSTIC RANGE IP ANSWERING SYSTEM be 4 B a THERMOREGULATION is B LANGUAGE ANSWERING SYSTEM Click on RANGE IP to display the page where the IP addresses can be entered for connection without password WebServerAVConfig INDIRIZZI IP SENZA AUTENTICAZIONE OPEN Nessun range ip impostato SCENARIOS LIGHTING CONFIGURAZIONE NUOVO RANGE IP Primo IP Be Secondo 1P T Confirm DATE TIME AUTOMATISM HOUSEHOLD APPLIANCE ALARM CONFIGURATION DIAGNOSTIC RANGE IP cCcTVv ANSWERING SYSTEM BB NE e e THERMOREGULATION H B Web Server eee 3 2 Configuration Language In this page the administrator user can configure the WebServerAVConfig Web page display language WebServerAVConfig SCENARIOS ai CO Italiano English Ce O Espafo
18. This is fundamental to guarantee consistency between the actions requested commands and carrying them out Obviously the access to the system command pushbuttons is subordinate to passing an identification page where a login identification name and a password known only by the user are requested If the identification has been successful the system can display the list of all the functions which can be activated and which were defined in the WebServerAVConfig configuration phase by means of the TiWebServerAVConfig program WebServerAVConfig PDA Entry SCENARIOS Ga LIGHTING AUTOMATISM APPLIANCE ALARM ccTV ANSWERING SYSTEM THERMOREGULATION Identification page Access allowed only to authorised users WebServerAVConfig SCENARIOS LIGHTING AUTOMATISM HOUSEHOLD APPLIANCE ALARM CCTV Control home page ANSWERING SYSTEM THERMOREGULATION SENE eae Two types of user can access the Web pages e administrator user e user user The administrator user can navigate in the same pages as the user user and can also access the CONFIGURATION function and define some WebServerAVConfig parameters such as for example the number of pictures to be saved in the video door entry answering system the e mail address to which alarm signals and or messages in the answering system should be sent login and password for access to the pages as user user etc Web Server 2 Base functions Example of
19. VConfig SCENARIOS LIGHTING AUTOMATISM HOUSEHOLD APPLIANCE ALARM No active alarm No lighted lamp 0 messages present in answering system cCcTV ANSWERING SYSTEM THERMOREGULATION SUSI ea en ESTE e On moving the mouse above the padlock the type of protection protocol used will be indicated SSL Secured 128 Bit To display the protection certificate click on the padlock or on the display certificate twice in the security alert window Certificato Generale Dettagli Percorso certificazione q Informazioni sul certificato Informazioni insufficienti per verificare il certificato Rilasciato a MyHome Bticino Rilasciato da BTICINO alido dal 08 08 2003 al 24 12 2030 Installa certificato Dichiarazione emittente The certificate indicates the issuer Legrand the date of validity of the protection certificate and who it was issued to Web Server A Attention if no action is performed for a time defined in the programming phase the WebServerAVConfig returns the user to the identification page whenever a second user enters the correct login and password values Note the administrator user login and password are defined with the TiWebServerAVConfig program The connection between PC and WebServerAVConfig is available for one access at once several users cannot connect with the WebServerAVConfig and thus with the system at the same time
20. a Web page WebServerAVConfig identification name System state WebServerAVConfig Activation interrogation address pushbuttons pushbutton WebServerAVConfig ee SCENARIOS Status Dimmer ON Timings Flashing TO Lena TES orr ile a automatism pee HOUSEHOLD Bedroom on oo Oo APPLIANCE Garden 1 o Gre State request a CCTV ANSWERING SYSTEM THERMOREGULATION Page 1 2 Functions Access to the State request availab le different pages pushbutton selectionarea yjt Stateofthe Icon ofthe pushbutton Information and relevant light function operation area selected 2 1 Scenarios By pressing pushbuttons displayed in the Web page this function can activate the scenarios saved in the Automation system scenario module item 03551 WebServerAVConfig SCENARIOS LIGHTING Day AUTOMATISM Night Cinema HOUSEHOLD APPLIANCE ALARM ccTv ANSWERING SYSTEM THERMOREGULATION SeEvueeaeGa 2 j The confirmation message Command sent is displayed in the page for each command sent suc cessfully Web Server a 2 2 Lighting In managing the LIGHTING function the web page displays the pushbuttons for sending the ON OFF Timing Flashing and dimmer control command WebServerAVConfig SCENARIOS ES AUTOMATISM gt amp HOUSEHOLD APPLIANCE ALARM CCTV ANSWERING SYSTEM THERMOREGULATION 1 k Detail of the pushbuttons and their functions Dimmer
21. an coil 4 If one or more sensors is faulty dashes zone Name fone 1 fone 2 Fone 3 ut are displayed Control unit mode Control unit with 4 zones 1 Manual 16 T M ae 28 2 16 28 4 16 2G 2 16 Season Summer Refresh State All the zones gt Knob 4 1 OFF Local Mode Manual Manual Manual Fan coil Cip Web Server E a When the bus connection is broken and no sensor zone manages to communicate all the zones will show dashes If the message The control unit does not respond appears in the part reserved for the control unit the zones which show dashes mean zone not reached Control unit mode Control unit with 4 zones 1 Manual 16 Season Summer Refresh State All the zones gt Zone Name T M T E Knob Mode Fan coil fone 1 a 7 z z fone 2 z 5 F z fone 3 3 5 5 Programming WebServerAVConfig SCENARIOS Control unit Programming LIGHTING Week program active LI AUTOMATION Scenario Active oO Weekend Active Choose Program Date 1 i ff Hour i i o Holiday Active Choose Program Dates Hour Oo Set Mode Choose Mode a a Set Temperature C 5 eee oO CENTRALUNIT ZONES HOUSEHOLD APPLIANCE ALARM cCcTV ANSWERING SYSTEM THERMOREGULATION A 3 The Programming Web page is divided into two
22. can signal thermoregulation system faults such as a faulty sensor by sending e mail messages via modem or LAN The texts of the messages sent are predefined and correspond to the definitions of the possible faults To activate this function when programming the device by means of the TiWebServerAV Config application enter the addresses of the addressee the sender the post server IP SMTP and any Router of the LAN to which the PC configured to receive emails is connected The administrator user can also configure the e mail address for the transmission via modem in the System Web page of the CONFIGURATION menu 23 24 Web Server Non controlled zones If the system includes temperature measurement sensors only non controlled zones the tem perature detected by them can be displayed in the appropriate web page WebServerAVConfig SCENARIOS bo UNCONTROLLED ZONES LIGHTING AUTOMATISM Zone Probe Temp HOUSEHOLD 2 Zona 1 APPLIANCE a ALARM CCTV ANSWERING SYSTEM JoHa THERMOREGULATION 2 9 External sensors If the system includes external radio sensor the temperature detected by them may be dis played WebServerAVConfig SCENARIOS EXTERNAL PROBES LIGHTING Zona 45 AUTOMATISM Update HOUSEHOLD APPLIANCE ALARM ccTv ANSWERING SYSTEM Jeonan THERMOREGULATION 2 L Web Server 3 Functions reserved for the administrator user I
23. cting the zone to be modified in the pull down menu and Antifrost in the Set mode line if the system is in winter mode season and Thermal protection if the system is in summer mode season The following picture will appear in the Zone State page DO legrand Temp Control Zone 1 Temperature Measured Aal Temperature 97 Expected Knob 3 Thermal Mode device Protection Fan coil Menu Temp Control The signalling of the zone in Antifrost mode will be given on the Control unit State Web pages and on the Control unit with the 3 icon The Off mode is activated in the Zone Programming page selecting the zone to be modified in the pull down menu and Off in the Set mode line The following picture will appear in the Zone State page Oi legrand Temp Control Zone 1 Temperature Measured Temperature Expected Knob 3 Mode Off Fan coil 27 1 27 Menu Temp Control The signalling of the zone in Off mode will be given on the Control unit State Web pages and on the Control unit with the icon Web Server SS SSS SS Diagnostic On the Diagnostic Web page a check can be made of the devices in the individual zones and if there is a fault on one or more zones of the system the anomaly can be signalled The following messages can be displayed e No anomaly found when the system works correctly e
24. d by the user Minimum Average Maximum and Automatic eu When the sensor is faulty and does not respond to the interrogations dashes apart from for Mode because this information is supplied by the control unit Temperature Measured ps Temperature Expected 1 Knob Se Moge Manual Fan coil ee will be displayed lf instead the bus connection is broken there is no power supply on the system or the WebServerAVConfig does not communicate just a series of dashes will be shown for all the items Temperature Measured Temperature Expected Knob Mone Fan coil 4 l Selecting All the zones from the pull down menu all the zones on the system configured with the TIMSERVER2 software displayed as below are interrogated one by one All the zones gt zone Name T M 7 6 fone 1 26 2 16 fone 2 26 4 16 fone 3 28 2 16 Knob n OFF Local Mlode Manual Manual Manual Fan coil EI The same information can be read for the single request of the zone collected in a single vertically sliding window The individual lines give the zone name the temperature measured the temperature expected the position of the sensor knob the zone mode of operation The presence of a Fan coil sensor with corresponding set speed zone Name T M T E fone 1 26 2 16 fone 2 26 4 16 fone 3 26 2 16 All the zones gt Knob 1 1 OFF Local Hode Manual Manual Manual F
25. date again If for some reason the control unit does not respond to the initial state or updating interrogation the following message is displayed Control unit mode Control unit with 4 zones 1 Manual 16 Season Summer Refresh State Interrogating the zones By selecting on the pull down menu the individual zones sensors can be interrogated or all together Temperature Measured 2 Temperature Expected 16 Knob Moge Manual Fan coil j 4 The information displayed is that which is visible on the control unit when the zone temperature is checked zone state menu e the zone sensor chosen e the temperature measured in the room where the sensor is e the temperature expected and set for that zone e the position of the sensor knob Local OFF Local Protection 0 1 2 3 in that zone e the zone mode of operation which will indicate Automatic when the sensor is set to work in the same modes selected in the control unit when these are in Week program Scenario Weekend or Holiday Manual when independent of the sensor setting the control unit is in Manual mode or when the sensor itself is in Manual mode Antifrost when the sensor has been set remotely in Antifrost mode Off when the sensor has been set remotely in Off mode e If afan coil speed regulation sensor is installed the page will also display the different speeds that can be selecte
26. e number of days in which this state will be maintained with the addition of the 3 icon The Manual mode is activated in the Control unit Programming page by selecting Manual in the Set mode pull down menu and entering the temperature value required The system will keep all the zones at this temperature until this mode is modified remotely or in the control unit The following picture will appear in the Control unit State page Temp Control Control unit mode Manual 15 Season Summer Refresh State Menu Temp Control The signalling of all the zones in Manual mode will be given on the Web pages and on the Control unit with the wording Manual and the temperature value set with no other icon Web Server E The parameters for the individual zones are set in the Zone Programming page e Manual in which temperatures can be set between 5 and 39 5 C with deviation of half a degree e Antifrost thermal protection in which the temperatures are fixed at 7 C antifrost or 35 C thermal protection e Automatic to return the zone selected to the operation set on the control unit when this zone has not been forced to different operation e Off in which the system can be switched OFF D legrand Temp Control fone Programming Zone Set Mode Choose Mode w Set Temperature C s v y P gt Activate Unlock room sensor settings Activate Fan coil
27. ess on the Answering System menu pushbutton to return to the main menu 5 7 Thermoregulation When the THERMOREGULATION function is selected the Web page displays five pushbuttons e Control unit state e Zone state e Control unit programming e Zone programming e Diagnostic legrand Temp Control Control Unit State Zone State Control unit Programming fone Programming Diagnostic Menu Temp Control The first two pushbuttons interrogate the system state the third and the fourth set the system parameters and the last performs a diagnosis of the system Web Server e Control unit state O legrand Temp Control Control unit mode Manual 16 5 Season Summer a w l a o Refresh State Menu Temp Control This page displays the information on e the mode of operation weekly manual scenarios weekend holiday OFF and antifrost thermal protection and the program which is active at that moment e the mode season of operation summer cooling winter heating e the system state icons indicates that one or more zones sensors are in the OFF state indicates that one or more zones sensors are in the MANUAL state indicates that one or more zones sensors are in ANTIFROST or THERMAL PROTECTION indicates that the remote control is disabled indicates that the control unit battery is flat HOURS amp indicates an operation fault in one or more zones of the system Pre
28. f you access the Web pages as administrator user the CONFIGURATION box appears in the func tion bar It has three pages e SYSTEM e ANSWERING SYSTEM e LANGUAGE 3 1 Configuration System In this page the administrator user can configure the login and password data for the user user Web access login password and telephone for access to the Internet via modem internet provider the number of rings for access to the modem from the local telephone line the sender and addressee of the e mails and the Ethernet configuration parameters for access to the WebServerAVConfig WebServerAVConfig SCENARIOS a WEB ACCESS E EMAIL ADDRESS Login bticino Address S R LIGHTING OO C AUTOMATISM CONFIGURATION ETHERNET wp 192 168 1 35 255 HOUSEHOLD a APPLIANCE amp Subnet Mask 255 255 ALARM Gateway 192 168 DNS1 vals pns2 7 ANSWERING SYSTEM Confirm THERMOREGULATION CONFIGURATION DATE TIME DIAGNOSTIC RANGE IP CONFIGURATION lo Gi b LANGUAGE ANSWERING SYSTEM To confirm the entered data press the amp pushbutton Clicking on TIME DATE gives access to the page to configure the date time and time zone data WebServerAVConfig SCENARIOS G LIGHTING AUTOMATISM Date 09H 02H 2009 HOUSEHOLD fg Hour 09 27 ko APPLIANCE Time Zone ALARM UPDATE DATE AND HOUR E Confirm AA ANSWERING SYSTEM CONFIGURATION DATE TIME DIAGNOSTIC RANGE IP
29. fig displayed in a second alter the ee quality In particular the lower SCENARIOS z the quality required the higher paia the frame rate AUTOMATISM HOUSEHOLD APPLIANCE ANSWERING SYSTEM ALARM 4 THERMOREGULATION BH Window to display the camera to be activated Activation and deactivation of the selected camera Horizontal vertical selection of the Activating door lock and light commands part enlarged Brightness Setting the brightness Contrast Setting the contrast A Attention the CCTV function is not available if the Video door entry answering system is recording a message Quality Setting the picture quality the more the picture definition is raised the longer it takes to refresh Zoom Picture enlargement reduction x 2 Web Server For Internet Explorer the possibility of displaying the camera pictures by means of an ActiveX has been added This Windows external module can display the pictures more smoothly To activate it select the pull down menu and select the option depending on the connection network used On pressing the activation pushbutton the following appears A You have chosen to use picture optimisation The First time the operation could take some time This is because Windows libraries are needed to use Activex If they are not on the PC they must be downloaded from the Internet If you have a fast ASDL connection the operation takes abou
30. gnalling alarms via e mail The WebServerAVConfig can signal anti intrusion events or auxiliary alarms such as gas leak flood ing etc by sending e mail messages via modem or LAN The texts of the messages sent are predefined and correspond to the alarm definitions given by the TiWebServerAVConfig application A compressed zip file can be attached to the messages contain ing the pictures in jpg format from the burglar alarm system camera To activate this function when programming the device by means of the TiWebServerAVConfig ap plication enter the addresses of the addressee the sender the post server IP SMTP and any Router of the LAN to which the PC configured to receive e mails is connected The administrator user can also configure the e mail address for transmission via modem in the CONFIGURATION menu System Web page Web Server SSS SS 2 5 CCTV When the CCTV function is selected and the Activate pushbutton pressed the Web page displays the picture sent from the camera selected in the CCTV system connected to the WebServerAVConfig By pressing the pushbuttons in the page the user can interact by selecting the camera required editing the picture parameters such as brightness contrast and colour or enlarging a specific area of the picture If the camera selected is an entrance panel camera the door lock and lighting can be activated Note to increase the picture frame rate number of pictures WebServerAVCon
31. gram in which you can select a week program configured with the TiWebServerAVConfig software or the last program selected e Activate Scenario in which you can select a scenario configured with TiWebServerAVConfig or the last program selected e Activate Weekend day in which a weekend day can be activated up to the time chosen The time set must be later than the current time and if no time is set the command is not sent e Activate Holiday in which the holiday can be activated with ending date and time e Manual in which temperatures can be set between 5 and 39 5 C with deviation of half a degree e Antifrost thermal protection in which the temperatures are fixed at 7 C antifrost and 35 C thermal protection e OFF in which the system can be switched OFF For any programming to be accepted it must be followed by pressing the Activate key on the right of the chosen program The command sent message is given in response To check remotely whether the control unit has received and accepted the command go to the Control unit State or Zone State pages and check that the control unit and or the programmed zone has modified its state If the system is in winter mode season in selecting the programs scenarios only the winter ones appear and the antifrost mode appears Vice versa if the system is in summer mode season the summer programs scenarios and the thermal protection mode a
32. he cess the box of the PC message to the Web where the presentation ServerAVConfig messages are wav file Answering system ON OFF pushbutton Indication in of the memory used Box to enable Confirmation e mail via Eth pushbutton ernet Web Server 4 Use of the WebServerAVConfig with Web Pages from handheld computer The interaction with the In One by Legrand systems connected to the WebServerAVConfig can also occur locally with Wi Fi connection Bluetooth or GPRS through Web pages specially written for use from handheld The Web pages previously configured and customised in the types of action to perform have control buttons for the communication with the system for the configuration see the TiWebServerAVConfig User manual When the browser is started enter the numerical address or URL Uniform Resource Locator standard method to indicate the logic address of a specific network resource e g 192 168 1 35 of the WebServerAVConfig to which the program must connect to set up a direct connection line to the In One by Legrand system ae ra The protection warning is displayed This indicates that the information exchanged with the site is encrypted according to the SSL 128 bit protocol and thus cannot be displayed or edited by other network users Press Yes to access the presentation page Security Alert i Information you exchange with this site cannot be viewed or S changed by others However the
33. ing window The individual lines give e the zone name e the temperature measured e the temperature expected e the position of the sensor knob e the zone mode of operation 3 7 38 Web Server G SSE__ __SSSSSSSSSSSSez eu If one or more sensors is faulty dashes are displayed My tral isiil i VWiit y J Temperature Measured Temperature Expected Temperature Measured Temperature Expected Thermal device Protection Fan coil Temperature Measured Temperature Expected Fan coil When the bus connection is broken and no sensor zone manages to communicate all the zones eu will show dashes The zones which show dashes mean zone not reached _Allthe zones gt Temperature Measured Temperature Expected Temperature Measured Temperature Expected Temperature Measured Temperature Expected u Temi To activate another function press on the Thermoregulation menu pushbutton to return to the main menu Web Server E Control unit Programming DO legrand Temp Control Control unit Programming Week program active Scenario Active Weekend Active Date Hour JT Holiday Active Date __ Hour JL Set Mode Choose Mode v Set Temperature C Bw i Menu Temp Control The parameters for the control unit are set in the Control unit Programming page in the seven modes provided e Activate Week pro
34. l E Portugues H O ntr LIGHTING AUTOMATISM HOUSEHOLD APPLIANCE ALARM ccTV ANSWERING SYSTEM THERMOREGULATION CONFIGURATION o The set default language is Italian but all the main European languages are available When the language required is selected and confirmed the Web pages will be displayed in the new language If the system is performing other operations a wait message will appear 3 3 Configuration Answering system In this page the administrator user can configure the number of photos from 1 to 16 which are saved on each call from the entrance panel select if provided a voice presentation message enable sending the messages recorded via e mail and activate deactivate the video door entry answering system service WebServerAVConfig SCENARIOS Photo number INTRODUCTION MESSAGE Present message wav LIGHTING AUTOMATISM HOUSEHOLD APPLIANCE New nessun file selezionato MEMORY Memory used i 0 ENABLE E MAIL Through ethernet wi ALARM ccTV ANSWERING SYSTEM Seo ales THERMOREGULATION CONFIGURATION lo Gj SYSTEM LANGUAGE ANSWERING SYSTEM x gt Details of the pushbuttons and the functions performed Number of photos which the WebServerAVConfig Confirmation can save for the answering system service pushbutton PHOTO a ad 2 28 Web Server EII ss Pushbutton to hear the message locally Pushbutton to ac Pushbutton to send t
35. mmer mode season the summer programs scenarios and the thermal protection mode appear The winter summer mode season cannot be modified remotely Weekend day must be activated in the Programming Control unit page selecting the program set in the control unit which is to be run on that weekend day and entering the date in the format dd mm yyyy and time in the format hh mm of that day When the system reaches that weekend day it will perform the program selected up to the time set At the end the system returns to Weekly mode with the program selected The following picture will appear in the General page SCENARIOS Control unit mode Holiday Season Summer LIGHTING AUTOMATISM Refresh State All the zones Knob Mode Manual HOUSEHOLD APPLIANCE w A e ALARM S CCTV ANSWERING SYSTEM Manual Sis TEMPERATURE CONTROL H 8 GENERAL PROGRAMMING DIAGNOSTIC ta Holiday must be activated in the Programming Control unit page selecting the program set in the control unit and entering the date in the format dd mm yyyy and time in the format hh mm of the end of the holiday period The system will stay in antifrost thermal protection mode until that date and will then return to the Week programming selected The following picture will appear in the General page SCENARIOS Control unit mode l acation Days 11 LIGHTING Season Summer AUTO
36. n CCTV Video door entry Lighting WebServerAVConfig You can also receive an e mail message with attached pictures in your post box when events are signalled as occurring in the burglar alarm system With the activation of the In One by Legrand WEB service the house can be managed remotely not only from the PC or handheld connected to the Internet but also from a landline or mobile phone Web Server E If the Personal Computer is to dialogue with the WebServerAVConfig it must have an Ethernet network card or a modem Each WebServerAVConfig in the system will be connected to the data network or to the telephone line to the 2 wire cable item 336904 of the digital video door entry system and to the 2 wire cable item L4669S of the burglar alarm system Example of connection to the WebServerAVConfig with Handheld by means of Router Modem Wi Fi INNIITTTTTE Telephone line ISP Internet Handheld Modem Router Wi Fi ethernet ee In One by Legrand LAN network systems Example of connection to the WebServerAVConfig with Handheld by means of GPRS connection of a mobile phone Handheld CJ GPRS mobile phone O YO 89 OO O O O Zo
37. ppear The winter summer mode season cannot be modified remotely 39 40 Web Server The Holiday day Weekend day must be activated in the Control unit Programming page selecting the program set in the control unit which is to be run on that weekend day and entering the date in the dd mm yyyy format and time in the hh mm format of that day When the system reaches that weekend day it will perform the program selected up to the time set At the end the system returns to Weekly mode with the program selected The following picture will appear in the Control unit State page Di legrand Temp Control Control unit mode Holiday Season Summer Refresh State Menu Temp Control Vacation Holiday must be activated in the Control unit Programming page selecting the program required set in the control unit and entering the date in the dd mm yyyy format and time in the hh mm format of the end of the holiday period The system will stay in antifrost thermal protection mode until that date and will then return to the Weekly programming selected The following picture will appear in the Control unit State page O legrand Temp Control Control unit mode Vacation Days 11 Season Summer Refresh State Menu Temp Control The signalling of all the zones in Holiday mode will be given on the Web pages and on the Control unit with the wording Holiday and th
38. re is a problem with the site s security certificate The security certificate was issued by a company you have not chosen to trust View the certificate to determine whether you want to trust the certifying authority The security certificate date is valid The name on the security certificate is invalid or does not match the name of the site Do you want to proceed The connection between handheld and WebServerAVConfig is available for one access at once thus several users cannot be connected with the WebServerAVConfig and thus with the system at the same time This is fundamental because it guarantees the consistency between the actions requested the commands and carrying them out Obviously the access to the system control buttons is subordinate to correctly filling in an iden tification page which requests a login identification name and a password which only the user LI legrand If the identification has been successful the list of all the types of function which the user can activate can be displayed These functions are those previously defined when programming the WebServerAVConfig using the TiWebServerAVConfig software D legrand Scenarios Lighting Automatism Alarm Household Appliance CCTV Answering System Temp Control Exit 29 Web Server E 5 Managing the 5 1 Scenarios functions Using the pushbuttons displayed in the Web page this function can activate the scenarios saved in scenario module
39. scription of the The Web Server item WebServerAVConfig can work on a In One by Legrand system installed in the house or offi ce The connection can be made via modem and or data network wired or wireless WebServerAVConfig The user using a Personal or handheld computer with commercial browser e g Internet Explorer 6 can connect locally or remotely with the WebServerAVConfig and nagivating via Web pages which can be customised which have icon menus and control pushbuttons perform the following operations e monitoring and command of the Automation management of loads lights rolling shutters etc Burglar alarm CCTV Power management and Thermoregulation systems e audio and video real time connection with the cameras in the CCTV system In particular you can see the picture transmitted by the camera selected being able from the PC to alter the picture quality framing and zoom listen to the message recorded by the microphone of the camera selected remote audible monitoring and send a message to the loudspeaker associated with the camera selected 2 way real time audio communication from Personal computer e listen to the audio messages and see the pictures on the Personal computer sent by video handset to the WebServerAVConfig when the Video door entry answer machine function is active The audio message and the picture can also be sent via e mail to an electronic postal address Thermoregulation Burglar alarm Automatio
40. ss the Update State pushbutton to ask the control unit to update again If for some reason the control unit does not respond to the initial state or updating interrogation the following message is displayed D legrand Temp Control The control unit does not respond Refresh State Menu Temp Control To activate another function press on the Thermoregulation menu pushbutton to return to the main Thermoregulation menu 33 36 Web Server Zone state Selecting on the pull down menu the individual zones sensors or all of them can be interrogated D legrand Temp Control Zone 1 Temperature Measured a4 Temperature 37 Expected Knob 3 Mode Manual Fan coil Menu Temp Control The information which is displayed is that which is visible on the control unit when the zone tem perature is checked zone state menu e the zone sensor chosen e the temperature measured in the room where the sensor is e the temperature expected and set for that zone e the position of the sensor knob Local OFF Local Protection 0 1 2 3 in that zone e the zone mode of operation which will indicate Automatic when the sensor is set to work in the same modes selected in the control unit when these are in Week program Scenario Weekend or Holiday Manual when independent of the sensor setting the control unit is in Manual mode or when the sensor itself is in Manual mode Antigelo
41. t ten seconds with a 56kb modem it takes up to ten minutes WebServerAVConfig SCENARIOS monday June 26 2008 15 10 52 LIGHTING 5 AUTOMA7 SM ALARM ANSWERING SYSTEM Using the ActiveX the Se ares oar P data on the date and time ao of filming are entered in the picture Pressing on a Help window appears which explains the meaning of the term Activex After installing ActiveX on your PC and pressing Activate Activex the operation described above is no longer performed even if the message continues to appear and the passage from slow picture to smoother picture will be immediate To deactivate the application click on the pull down window and select No Activex On pressing the deactivation pushbutton the following appears A You have chosen not to use picture optimisation The picture quality may not be the best possible Web Server Ee 2 6 Answering system When the ANSWERING SYSTEM function is selected the Web page displays pictures and voice mes sages from the entrance panel saved by the WebServerAVConfig if the Video door entry Answering system function was activated By pressing the push buttons in the page the user can listen to cancel the messages and click on the pictures to enlarge them The user can configure the answering system service with the TiWebServerAVConfig program or via the Web pages as administrator user by selecting CONFIGURATION
42. the light point writing Timing selection Flashing frequency selection Dimmer setting Oi legrand Oi legrand D legrand Lighting Lighting Lighting Living Room og Bedroom no Kitchen no Timings selezic jw Flashing selezic jw ooo 000000 Back Back Back Refresh Menu Press the Refresh Update pushbutton to check the system state Press the Back pushbutton to return to the main page of the Lighting menu 5 3 Automation In managing the AUTOMATION function the Web page displays the pushbuttons for sending the UP DOWN and STOP command O legrand Automatism Shutter 1 Shutter 2 General The confirmation message Command sent is displayed for each command sent successfully If the command was not successful the Command not sent message is displayed To activate another function press the Menu pushbutton to return to the main menu 31 52 Web Server 5 4 Alarms When the ALARMS function is selected the Web page displays the state of the burglar alarm system with a text If there is an alarm the message indicates the type of alarm e g intrusion alarm tamper ing alarm or technical alarm and where it came from e g living room D legrand Alarm No alarm activated System condition Mantenance Deactivated Battery OK Net OK Zones activated Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zones deactivated Refresh Menu If
43. their integrity and origin Today 128 bit message cryptography represents the best security system for sending reserved information via Internet and is the system used by banks throughout the world Because it is standard it is used by the main Browsers Explorer Opera If Internet Explorer is used after entering the URL the encryption system rewrites http as https the s indicates that the site uses the SSL protocol and displays the following security alert Security Alert Information you exchange with this site cannot be viewed or S changed by others However there is a problem with the site s security certificate The security certificate was issued by 4 company you have not chosen to trust View the certificate to determine whether you want to trust the certifying authority The security certificate date is valid The name on the security certificate is invalid or does not match the name of the site Do you want to proceed ves Press Yes to access the identification page Web Server Note the protection certificate is issued by Legrand Every time you connect to the WebServerAVConfig the security alert is shown as reminder and guarantee of a secure system because it is not visible and cannot be edited by third parties Note the padlock in the Internet Explorer window bottom right indicating a secure connection g Pa https 192 168 1 35 apertura php Ka coge WebServerA
44. tronic mail server ISP after configuring the WebServerAVConfig again with TiWebServerAVConfig If the problem continues contact the technical after sales service 7 3 TheWebServerAVConfig does not perform the commands sent to the In One by Legrand systems e If there is an annoying echo during a remote real time connection with the video door entry system check the settings of the audio card installed on the PC Use headphones instead of loudspeakers to avoid the echo effect e If when a camera is switched ON there is a black picture on the Web page wait for at least one minute and try again e If when a camera is switched ON service not available appears on the Web page wait for at least one minute and try again e If the device does not save the Video door entry answering system messages make sure that the Video door entry answering system function has been activated e Ifmessages which have already been cancelled appear in the Answering machine Web page enter the Browser program configuration screen and cancel the cache Then set the Browser program so that it does not recover pages from its cache 45 46 47 Ll legrand World Headquarters and International Department 87045 LIMOGES CEDEX FRANCE 33 5 55 06 87 87 Fax 33 5 55 06 74 55 www legrandelectric com
45. when the sensor has been set remotely in Antifrost mode Off when the sensor has been set remotely in Off mode When the sensor is faulty and does not respond to the interrogations dashes will be displayed apart from for Mode because this information is supplied by the control unit D legrand Temp Control Zone 1 Temperature Measured Temperature Expected Knob Mode Manual Fan coil Menu Temp Control Web Server a If instead the bus connection is broken there is no power supply on the system or the WebServer AVConfig does not communicate just a series of dashes will be shown for all the items O legrand Temp Control Zone 1 Temperature Measured Temperature Expected Knob Mode Fan coil Menu Temp Control Selecting All the zones from the pull down menu all the zones on the system configured with the TIMSERVER2 software displayed as below are interrogated one by one D legrand Temp Control Allthe zones fone 1 Temperature Taau mies Temperature 27 Expected Knob 3 Mode Manual Fan coil Zone 2 Temperature 26 6 Measured Temperature 35 Expected Knob 1 Thermal Mode device Protection Fan coil fone 3 Temperature 28 5 Measured Temperature 35 Expected Knob 1 Thermal Mode device Protection Fan coil Menu Temp Control The same information can be read of the single request of the zone collected in a single vertically slid