Home

Etherbus IP67 (Water

image

Contents

1. Protocol independent The Etherbus Industrial Ethernet Switch will work with all popular Ethernet protocols and networks such as TCP IP the Internet IP UDP NetBEUI and many more It is compatible with all protocols that run over standard Ethernet IEEE 802 3 In fact it will support packets of different protocols simultaneously Etherbus Switch User Manual Page 12 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Section 7 Technical Specifications Technical Here are the technical specifications for the Etherbus Industrial Ethernet Switch covered by this Specifications manual Industrial Ethernet Switch EB GT 8ES 1 10 100BaseT x Ports 10 100BaseT x ports Protocols supported Ethernet compliancy Auto mdi mdix crossover Auto negotiating speed Flow control Ethernet isolation Plug and play Cable requirements Max cable distance Shielded RJ45 All standard IEEE 802 3 IEEE 802 3 All 8 ports 10BaseT or 100BaseTX Half or Full Duplex 1500 VRMS 1 minute es Twisted pair Cat 5 shielded recommended 100 meters Environmental Etherbus Switch User Manual Page 13 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com RJ45 to RJ45 Passthru Bulkhead Connector EB CP RJ45 F includes cap with tether Coupling Nut Material Recom
2. Auto crossover auto mdi mdi x The RJ45 ports will automatically detect the cable type straight thru vs cross wired and re configure themselves accordingly Auto sensing or auto negotiating speed The RJ45 ports of the Etherbus Industrial Ethernet Switch will auto negotiate with the connected device to determine the optimal speed 10 Mbps vs 100 Mbps for each port Automatic power saving If there is no cable on a port most of the circuitry for that port is disabled to save power Backoff operation The Etherbus Industrial Ethernet Switch will drop a packet after 16 collisions Back pressure for half duplex The Etherbus Industrial Ethernet Switch will apply back pressure when necessary with half duplex operation This back pressure will reduce congestion on busy networks Broadcast storm protection Broadcast messages are limited to 5 of the available bandwidth Unicast and multicast messages are not limited Buffering SRAM is used for buffering the messages There are 1024 128 bytes each buffers available Each port is allocated 113 buffers Etherbus Switch User Manual Page 11 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Unmanaged operation The Etherbus Industrial Ethernet Switch requires no supervisory processor to operate properly Flow control The Etherbus Industrial Ethernet Switch automatically supports flow c
3. Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Section 4 Power Wiring Overview The Etherbus Industrial Ethernet Switch can be powered from the same DC source that is used to power your I O devices 10 to 30 VDC needs to be applied to the mating DC power connector supplied with the switch The integrated screw terminals can accept up to 16 AWG wire Refer to the wiring diagrams below 4 Chassis 4 Chassis 1N C A T a las 2DC SD4 2 DC 3DC Male Power Connector Screw Terminal Side of Field on Switch Installable Power Connector Connector The assembly of the field installable power connector EB CC PS F1 requires no special tools Assembly just a standard small slotted screwdriver The power cable should be between 6 and 8 mm in diameter Simply install the components in the order shown below First strip off 1 4 of the plastic sheathing on each conductor of your power cable Tightly twist stranded cable so there are no loose strands Second slide component 1 then 2 then 3 over your power cable in the orientation shown below Keep these first 3 components loose Do not tighten them yet Third using the integrated screw terminals attach component 4 to the appropriate conductors of your power cable Refer to the wiring diagram above Fourth screw component 3 to component 4 Finally slide component 2 into component 3 and then screw component 1 to component 3 You now have
4. SUEXNET makes no warranties whatsoever with respect to implied warranties of merchantability or fitness for any particular purpose All such watranties are hereby expressly disclaimed No oral or written information or advice given by SIXNET or SIXNET s representative shall create a warranty or in any way increase the scope of this warranty This limited warranty is in lieu of all other warranties whether oral or written expressed or implied SIXNET s liability shall not exceed the price of the individual units which are the basis of the claim In no event shall SIXNET be liable for any loss of profits loss of use of facilities or equipment or other indirect incidental or consequential damages INSTALLATION AND HAZARDOUS AREA WARNINGS These products should not be used to replace proper safety interlocking No software based device or any other solid state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular SLXNET disclaims any responsibility for damages either direct or consequential that result from the use of this equipment in any application All power input and output I O wiring must be in accordance with Class I Division 2 wiring methods and in accordance with the authority having jurisdiction WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIVISION 2 WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATI
5. 16 40 VDC 1EP Ethernet Standards IEEE 802 3 10BaseT 802 3u 100BaseTX 802 3x Full Duplex Ethernet Protocols All standard IEEE 802 3 protocols supported Speed Per Port RJ45 10 Mbps half duplex or 200 Mbps full duplex Ethernet Isolation 1500 Volts RMS for 1 minute Operating Temp 40 to 70 C 1 40 TO 60 C 1EP Humidity 5 to 100 RH Vibration IEC 68 2 6 or better completely potted design for max resistance Standards and Safety The Etherbus Industrial Ethernet Switch meets the following standards Electrical safety UL 508 CSA C22 14 EN61010 1 IEC1010 C SA EMI emissions FCC part 15 ICES 003 EN55022 Class B EMC immunity EN61326 1 EN61000 4 2 3 4 and 6 Aus Hazardous locations UL 1604 CSA C22 2 213 Class 1 Div 2 Groups A B C D LISTED Cenelec EN50021 Zone 2 Install the Etherbus Industrial Ethernet Switch in accordance with local and national electrical codes Lightning Danger Do not work on equipment during periods of lightning activity Do not connect a telephone line into one of the Ethernet RJ45 connectors Etherbus Switch User Manual Page 3 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Section 2 LED Indicators Overview The Etherbus Industrial Ethernet Switch has communication LEDs for each port and a power LED This LED will be on solid when proper
6. Switch is waterproof and therefore can be mounted directly to any flat surface Refer to the mechanical drawings below 2 10 3 75 53 mm 95 mm 0 50 0 20 7 295 13mm 5mm 75 mm 1 A i El J nw i i T 0 45 11 mm 10 15 258 mm 10 75 273 mm A i EB GT 8ES IP67 Industrial Ethernet Switch 3 35 eo 7 8 16UN Bi EB CC PS F Field Installable IP67 Power Connector 1065 270 Etherbus Switch User Manual Page 5 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com L96 REF 498mm 3 4 CONDUIT NUT NITRILE O RING 84 REF 21 3mm 52 REF 13 2mm 2 REF 15 7 mn i RJ45 CONNECTOR 1 14UNC THREAD 062 THICK NITRILE GASKET 1 50 REF 38 1mm EB CP RJ45 F RJ45 to RJ45 IP67 Bulkhead Passthru Connector Required hole size 1 063 27mm 1 30 REF 33 0mm 1 12 REF 2 00 REF 50 8mm 2 30 REF 58 4mm EB CC CAT5 M Field Installable IP67 RJ45 Connector Etherbus Switch User Manual Page 6 of 15 Revised 16 Dec 05 SIXNET 331 Ushers
7. power has been applied to the unit ACT LNK The activity ACT and link LNK indication is combined into one LED on the Etherbus LEDs Industrial Ethernet Switch There is one of these LEDs per port OFF This would indicate that there is not a proper Ethernet connection Link between the port and another Ethernet device Make sure the proper cable type is in use and that it has been plugged securely into the ports at both ends See section 5 for proper Ethernet cabling ON Solid not flashing This would indicate that there is a proper Ethernet connection Link between the port and another Ethernet device but no communications activity is detected Flashing This would indicate that there is a proper Ethernet connection Link between the port and another Ethernet device and that there is communications activity 10 100 This LED indicates what speed of communications is detected on the port There is one of these LEDs LEDs per RJ45 port The fiber optic port does not have one of these LEDs because its speed is fixed at 100 Mbps OFF A 10 Mbps 10BaseT connection is detected ON A 100 Mbps 100BaseTx connection is detected Mbps Megabits per Second Etherbus Switch User Manual Page 4 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Section 3 Dimensions and Installation Overview The Etherbus Industrial Ethernet
8. 2 then 3 over your un terminated Ethernet cable in the orientation show below Keep these first 3 components loose Do not tighten them yet Third using your crimping tool attach the supplied RJ45 connector to your Ethernet cable Follow the instructions that come with your crimping tool Fourth push the attached RJ45 connector firmly into component 3 Fifth firmly screw component 2 to component 3 Finally slide component up over component 3 You now have a watertight IP67 RJ45 Ethernet connector Note You may have also been supplied a C retaining clip It s recommended that you test your cable before installing this retaining clip to component 3 Bulkhead The RJ45 to RJ45 passthru bulkhead connector is also simple to install First punch a 1 063 27 Connector mm diameter 3 4 conduit punch out hole in your cabinet or panel Remove the 34 conduit nut If you are going to install the tethered cap supplied then also remove the rubber gasket Slide the integrated gasket end of the tether over where the original gasket was located It s not recommended to use both gaskets at the same time Insert the assembly into your hole punch out from the outside Then firmly screw on the 34 conduit nut from the inside Recommended tightening torque is 6 in lbs 07 kg m You now have a watertight IP67 RJ45 to RJ45 passthru connector Etherbus Switch User Manual Page 10 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 76
9. 7 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Section 6 Switching Features Switching Here are brief explanations of the features found in the Etherbus Industrial Ethernet Switch Features documented by this manual 10BaseT and 100BaseTx Auto detection Standard Ethernet 10BaseT has a maximum speed of 10 Mbps in half duplex mode Fast Ethernet 100BaseTx has a maximum speed of 200 Mbps in full duplex mode The RJ45 ports on the Etherbus Industrial Ethernet Switch will automatically select the appropriate speed 2 0 Gbps combined bandwidth With full duplex and 1O0BaseTX communications each port can provide a full 200 Mbps of data throughput 1K MAC addresses with automatic learning aging and migration Each Ethernet device inserts its unique MAC address into each message it sends out The port on the switch used for a given MAC address is automatically learned when a frame is received from that address Once an address 1s learned the switch will route messages to only the appropriate port instead of broadcasting messages out all ports like a hub A time stamp is also placed in memory when a new address is learned This time stamp is used with the aging feature which will remove unused MAC addresses from the table after 300 seconds If a device moves the associated port on the switch will be changed migrated as needed Up to 1 024 MAC addresses can be stored and monitored at any time
10. ONS DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Copyright amp Trademarks Copyright SIXNET All Rights Reserved Etherbus is a registered trademark of SLXNET Note All information in this document is subject to change without notice Etherbus
11. SIXNET Etherbus IP67 Ethernet Real time Switch amp Accessories Section 1 General Information Page 3 Section 2 LED Indicators Page 4 Section 3 Dimensions amp Installation Page 5 Section 4 Power Wiring Page 7 Section 5 Ethernet Wiring Page 8 Section 6 Switching Features Page 11 Section 7 Technical Specifications Page 13 Section 8 Service Information Page 15 Applicable standards and certifications ISO C US C 9001 LISTED Total Quality Hazardous Locations Standard Locations European Directives Marine amp Offshore US Emissions This manual applies to the following products EB GT 8ES IP67 Industrial Ethernet Switch EB CP RJ45 F IP67 RJ45 to RJ45 Passthru Bulkhead Connector EB CC CAT5 M IP67 Field Installable RJ45 Connector EB CC PS F IP67 Field Installable Power Connector EB CC CAP L IP67 Protective Cap with Tether Etherbus Switch User Manual Page 1 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com SIXNET Protected Technology Policy SIXNET protects your investment in SIXNET systems with long term planned technology and our unique Protected Technology Policy We will continue to support the specified capabilities of standard SIXNET products for at least five years We plan each product improvement and new feature to be upward compatible with existing designs and installations Our goals are to make
12. Switch User Manual Page 2 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Section 1 General Information Overview This manual will help you install and maintain the Etherbus Industrial Ethernet Switch and accessories This unmanaged Switch is extremely easy to install and operate because little or no user configuration is required Once the Ethernet connections are made and the unit is powered up it will immediately begin to operate Unlike an Ethernet hub that broadcasts all messages out all ports the Etherbus Industrial Ethernet Switch will intelligently route Ethernet messages only out the appropriate port The major benefits of this are increased bandwidth and speed reduction or elimination of message collisions and deterministic performance when tied with real time systems Operation The Etherbus Industrial Ethernet Switch supports both 10BaseT 10 Mbps and 100BaseTx 100 Mbps on its RJ45 ports Each of these ports will independently auto sense the speed allowing you to interface to regular or fast Ethernet devices Refer to Section 6 for more information on Industrial Ethernet Switch operation and features Performance These general specifications apply to the Etherbus Industrial Ethernet Switch Refer to Section 7 Specs for complete technical specifications Ports 10 100BaseT x Shielded RJ45 Required Voltage 10 30 VDC 1
13. a watertight IP67 power connector Etherbus Switch User Manual Page 7 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Section 5 Ethernet Wiring Overview The Etherbus Industrial Ethernet Switch provides connections to Ethernet devices on the factory floor Typically the uplink port is used to connect to another Ethernet switch or hub that is connected to the main Ethernet backbone The other four Ethernet ports are then connected to Ethernet devices such as PLCs Ethernet I O or industrial computers Electrical isolation is provided on the Ethernet ports for increased reliability Please follow normal 10 100BaseT x amp 100BaseFX wiring practices when installing the Etherbus Industrial Ethernet Switch Main Ethernet Backbone Office grade switch e ndustrial switch a Ethernet Switch Installation i ho FACTORY FLOOR Fihernet enabled incusiis Control Cabinet Computer Ethernet IO Ethernet Ethernet RJ45 Cable Type RJ45 Wiring Use data quality not voice quality twisted pair cable rated category 5 For best performance use eT A MaS shielded cable Please note that these cables are available or can be wired as straight thru or cross over configurations For connections to the Etherbus switch either cable type will work because the Etherbus switch supports auto crossover auto mdi mdix and will auto detect the cable and adjust
14. accordingly Straight thru Cable Wiring Cross over Cable Wiring Etherbus Switch User Manual Page 8 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Ethernet Connector Pin Positions Ethernet Connector Pin Assignments X Cable Distance The maximum cable length for 10 100BaseT x is typically 100 meters 328 ft Refer to the following chart for some general guidelines Switch Switchor Hub 100 meters 328 feet Note Hubs and Switch are different devices Hubs simply broadcast all messages out all ports Switch intelligently route messages only out the appropriate port The device described in this manual is a Switch Field Installable The field installable RJ45 connector EB CC CAT5 M is easy to install A standard RJ45 RJ45 Connector crimping tool is required Follow the instructions that come with the tool on how to attach the supplied RJ45 connector to your Ethernet cable Category 5E cable is highly recommended See the upcoming instructions for exact details on how to assemble this connector Etherbus Switch User Manual Page 9 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Simply install the components in the order shown below First slide the o ring over component 3 if it isn t already Second slide component 1 then
15. address SIXNET 331 Ushers Road P O Box 767 Clifton Park NY 12065 Etherbus Switch User Manual Page 15 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com
16. each new software release bring new power to your SIXNET systems and have every existing feature applications program and data file continue to work We protect your investment even further with a liberal five year trade in policy Exchange standard products for upgraded versions of the same product to take advantage of new features and performance improvements at any time for five years A prorated trade in allowance will be given for your existing equipment SIXNET protects your long term productivity with state of the art planned technology and continued support SIXNET Statement of Limited Warranty SIXNET LLC manufacturer of SIXNET products warrants to Buyer that products except software manufactured by SLIXNET will be free from defects in material and workmanship SIXNET obligation under this warranty will be limited to repairing or replacing at SIXNET option the defective parts within one year of the date of installation or within 18 months of the date of shipment from the point of manufacture whichever is sooner Products may be returned by Buyer only after permission has been obtained from SIXNET Buyer will prepay all freight charges to return any products to the repair facility designated by SIXNET This limited warranty does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation maintenance misuse neglect or any cause other than ordinary commercial or industrial applications In particular
17. epair purchase order number in case the repair is not covered under our warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on the RMA form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in the fastest manner Normally repairs are completed in two days Sometimes difficult problems take a little longer to solve If you need a quicker turnaround ship the unit to us by air freight We give priority service to equipment that arrives by overnight delivery Many repairs received by mid morning typical overnight delivery can be finished the same day and returned immediately We apologize for any inconvenience that the need for repair may cause you We hope that our rapid service meets your needs If you have any suggestions to help us improve our service please give us a call We appreciate your ideas and will respond to them For Your Convenience Please fill in the following and keep this manual with your SIXNET system for future reference P O Date Purchased Purchased From Product To obtain support for SIXNET products Support On line support www get2support com Order on line www industrialmodem com Latest product info www sixnetio com Phone 1 518 877 5173 Fax 1 518 877 8346 E mail support sixnetio com Mailing
18. mended Tightening Torque Field Installable RJ45 Connector EB CC CAT5 M O Ring Material Field Installable Power Connector EB CC PS F Housing Connector Contacts Coupling Nuts Conductors Protective Cap with Tether EB CC CAP L for use with Etherbus switch not for use with bulkhead UNC 1 14 Etherbus Switch User Manual Page 14 of 15 Revised 16 Dec 05 SIXNET 331 Ushers Box 767 Clifton Park NY 12065 USA 1 518 877 5173 mailto support sixnetswitch com Section 8 Service Information Service We sincerely hope that you never experience a problem with any SIXNET product If you do need information service call SIXNET at 518 877 5173 and ask for Applications Engineering A trained specialist will help you to quickly determine the source of the problem Many problems are easily resolved with a single phone call If it is necessary to return a unit to us an RMA Return Material Authorization number will be given to you SIXNET tracks the flow of returned material with our RMA system to ensure speedy service You must include this RMA number on the outside of the box so that your return can be processed immediately The applications engineer you are speaking with will fill out an RMA request for you If the unit has a serial number we will not need detailed financial information Otherwise be sure to have your original purchase order number and date purchased available We suggest that you give us a r
19. ontrol frames on both the transmit and receive sides Forwarding The Etherbus Industrial Ethernet Switch supports store and forward mode It will forward messages with known addresses out only the appropriate port Messages with unknown addresses broadcast messages and multicast messages will get forwarded out all ports except the source port The Etherbus Industrial Ethernet Switch will not forward error packets 802 3x pause frames or local packets Full Half duplex operation The RJ45 ports of the Etherbus Industrial Ethernet Switch support both full and half duplex flow control Illegal frames Illegal frames as defined by IEEE 802 3 will be dropped This includes short frames long frames and FCS error frames IEEE 802 3 compliant The Etherbus Industrial Ethernet Switch strictly abides to the IEEE 802 3 standard for 10BaseT and 100BaseTX Ethernet communications Late collision If a packet experiences collisions after 512 bit times of transmission the packet will be dropped Latency The typical latency of a message is 5 microseconds or faster The latency is the time it takes a message to be routed internal to a switch from one port to another Plug and play This means that most functions or features of the Etherbus Industrial Ethernet Switch are automatic and that there are minimal or no optional parameters that need to be set Just plug in your Ethernet cables apply power and the unit will immediately begin to operate