1. SNAP ON KOOL KARE EEAC304C R 134a UNIT SETUP 1of5 Installation Instructions INSTALLATION MUST BE PERFORMED BY QUALIFIED SUN PERSONNEL ONLY INSTALLATION OVERVIEW The Installation Procedures listed are for the SNAP ON KOOL KARE unit The unit is shipped as a fully assembled unit with the exception of the items listed in the Parts amp Accessories List PLEASE READ THESE INSTRUCTIONS COMPLETELY BEFORE SETTING UP UNIT A CAUTION THIS UNIT MUST BE PLUGGED INTO A PROPER AC OUTLET FOR UNIT TO OPERATE CORRECTLY REFER TO THE UNIT ID PLATE LOCATED ON BACK OF UNIT EXTENSION CORDS ARE NOT RECOMMENDED BUT IF AN EXTENSION CORD MUST BE USED USE A CORD THAT IS LESS THAN 50 FEET WITH A 16 AWG OR ABOVE 50 FEET AND LESS THAN 100 FEET WITH A 14 AWG A WARNING USE STANDARD REFRIGERANT HANDLING SAFETY PROCEDURES WHEN PERFORMING INSTALLATION ALWAYS WEAR SAFETY GOGGLES DON T SPILL OR TOUCH LIQUID REFRIGERANT AVOID FLAMES AND EXCESSIVE HEAT USE ONLY IN WELL VENTILATED AREA TEEAC304C 02 02 1999 REV A Page 2 of 5 PARTS amp ACCESSORIES PART NUMBER DESCRIPTION QTY EAH0001C02A Hose 96 R 134a Blue 1 EAH0001C01A Hose 96 R 134a Red 1 TEEAC304C Installation Instructions 1 EAK0027C00AS Kit Vehicle Adapter O Ring 1 SS1386VHS Video Tape 1 ZEEAC304C Users Manual 1 1585 Bottle Oil Charge 1 16826 Screw 8 32x3 1 115080 Adapter Low Side Tank For Virgin Tank to Low Side Adapter 1 07180108 Holders Hose P Clip
2. efer to FIGURE 4 FIGURE 4 INSTALLING TANK TEEAC304C 02 02 1999 REV A Page 5of5 CHARGING RECOVERY TANK NOTE THIS PROCEDURE IS USED TO SETUP THE UNIT FOR CHARGING RECOVERY TANK SHOULD HAVE AT LEAST A 25 VACUUM THIS PROCEDURE IS DONE WHEN RECOVERY TANK IS ON THE SCALE 1 Be sure Recovery Tank valves B are closed Refer to FIGURE 5 2 Disconnect the Red and Blue hoses from the S Recovery Tank ZL 3 Connect the low side tank adapter to the Red Valve on the Recovery Tank B 4 Connect the blue service hose C w vehicle I adapter to the low side tank adapter Open vehicle A adapter A 5 Connect the other end of the blue service hose tothe pa Virgin Tank A Raise the Virgin Tank to a higher NI level than the Recovery Tank Open the Red Valve on the Recovery Tank A Fi Invert the Virgin Tank A and open valve Gravity i and vacuum will transfer the liquid refrigerant to the iu Recovery Tank faster than reclaiming it o je zl 8 Press lt AMOUNT gt to display the amount of refrigerant that has been transferred 9 After the desired amount of refrigerant has been transferred close valves on Virgin Tank and Ss 5 Recovery Tank Set Virgin Tank on ground upright 10 Disconnect the blue service hose from recovery tank FIGURE 5 CHARGING TANK Disconnect the low side tank adapter from recovery tank Connect adapter to low side service port
3. et Turn unit on using the front power switch TANK ADAPTER 115080 FIGURE 2 RECOVERY TANK A CAUTION THIS UNIT MUST BE PLUGGED IN TO A PROPER AC OUTLET FOR UNIT TO OPERATE CORRECTLY REFER TO UNIT ID PLATE LOCATED ON BACK OF UNIT EXTENSION CORDS ARE NOT RECOMMENDED BUT IF AN EXTENSION CORD MUST BE USED USE A CORD THAT IS LESS THAN 50 FEET WITH A 16 AWG OR ABOVE 50 FEET AND LESS THAN 100 FEET WITH A 14 AWG TEEAC304C 02 02 1999 REV A Page 4of 5 PREPARING NEW RECOVERY TANK continued 6 Following the displays in FIGURE 3 to program a 10 minute vacuum time Will you Recycle STARTIN Gs from Vehicle this SCREEN sequence YES NO O O e Enter time to pull Tian 7 Vacuum on vehicle ae puing 10 minutes e YES sequence UP DOWN ENTER YES NO e O e e O S Enter time to hold Will you be charging acuum ___ this sequence 00 minutes ee UP DOWN ENTER YES NO O O J O O e FIGURE 3 VACUUM MODE 7 Once completed close Recovery Tank valve BLUE and remove Service Hose from Recovery Tank Remove tank adapter Replace the Particle Filter to the Recovery Tank BLUE SIDE Place Recovery Tank on scale Tank fittings should face straight out the back of unit Connect velcro strap and tighten belt 10 Remove bubble wrap from Red and Blue Hoses on unit near the recovery tank 11 OIL seals on the anti blow back valves on Red and Blue Hoses from unit Connect respectively to Recovery Tank R
4. m the service ports respectively Remove the two P Clip Hose Holders 07180108 and Screw 16826 from the accessories box Slide the red and blue hoses through the p clips Using the supplied screw mount both p clips to the unit s back panel near the cord wrap Place the O Ring Kit EAKO027COOAS on top of unit Remove the Oil Charge Bottle 1585 from the accessories box Attach the oil charge bottle to the port just below the power switch on front of unit Refer to the User s Manual on operation of the Oil Charge feature Peel the backing from the User s Manual Envelope 4211000101 and apply the envelope with the open end on top to either side of the unit or in the location designated by the customer Remove the User s Manual and place the remainder of the documents in the envelope BE SURE TO REVIEW THE USER S MANUAL WITH THE CUSTOMER DURING TRAINING Place the User s Manual in the Envelope Remove Recovery Tank 7009244701 from its box Remove cardboard wrap from Recovery Tank Set on floor in front of unit PREPARING NEW RECOVERY TANK 1 Referring to FIGURE 2 open the BLUE valve on Recovery Tank to release ALL COMPRESSED AIR Remove the Particle Filter from the Recovery Tank OIL seal BLUE VALVE Attach Low Side Tank Adapter 115080 to the BLUE valve of Recovery Tank DO NOT OVER TIGHTEN Connect the BLUE service hose to the low side tank adapter Open the vehicle adapter Plug AC Cord to a 115VAC outl
5. on back of unit 11 Re Oil seals on anti blow back valves on Red and Blue Hoses from unit and connect to Recovery Tank Open Recovery Tank valves 12 Connect the blue service hose to the service port This is a backward configuration than a normal operation 13 Following the displays in FIGURE 6 perform a recover mode This will reclaim the refrigerant from STARTING fromehinictne the hose Optional Opening Virgin Tank valve will SCREEN sequence reclaim rest of refrigerant YS E no 14 Once complete disconnect the blue service hose WiN you be pulling from Virgin Tank and service port Disconnect the Sequence low side tank adapter YES NO 15 Re install the blue service hose correctly to the 2 i Will you be charging service port this sequence YES NO REMEMBER TO OIL O RINGS AND SEALS O O e WHEN ATTACHING HOSES OR FITTINGS FIGURE 6 RECOVER MODE INSTALLATION COMPLETE SETUP COMPLETE TEEAC304C 02 02 1999 REV A
6. s 2 0647028707 Adapter Vehicle High Side Coupler 1 0647028708 Adapter Vehicle Low Side Coupler 1 0692191401 MAC s Form Mail In 1 0692192801 Product Registration Form 1 0692224201 MAC s Certification Form 1 4211000101 Envelope 1 0692229101 Product amp Warranty Registration 1 7009244701 Recovery Tank Assembly 1 REQUIRED TOOLS e Screwdriver Flat Blade and Phillips e Safety Goggles 0001 5005 e Refrigerant Oil Mineral or Superlube 0681 0193 02 or 03 UNPACKING UNIT AND ACCESSORIES 1 Cut Straps A and slide the carton B off the pallet C 2 Remove the top of the carton D and packing foam E from unit Split the corners of the base carton F 3 Remove all boxes G and packing material H from scale tank compartment 4 Lean the unit I so it can be rolled off the base carton F Lean one side of unit I so packing foam J can be removed Repeat for other side 6 Inventory all items G using the Parts amp Accessories list and inspect for damage 7 Discard scale guard H FIGURE 1 UNIT PACKAGE TEEAC304C 02 02 1999 REV A Page 3 of 5 PARTS amp ACCESSORIES SETUP 10 Remove the Blue and Red Hoses from the accessories box and OIL the seals on each end Connect the open end of the Blue and Red Hoses to the low and high side service ports respectively on the backside of unit Connect the Red and Blue adapters 0647028707 and 0647028708 to the Red and Blue Hoses fro