FR1500 & FR1500G Parts List
Contents
1. The fire is supplied with 45 pebbles of various colours These are arranged with 23 Pebbles along the back 22 pebbles along the front The pebbles must not touch the burner and are positioned on the vanity cover See images below Add the Wool between the pebbles and along the burner bar Do not place any wool near the pilot assembly The wool should only be in the centre section Refit the Vanity Shelf The vanity Shelf is secured by 4x cross headed screws These must be fitted and the shelf fixed in place WARNING If the shelf is left loose and the fire used the vanity will be damaged by the burner flame and the remote system will over heat and become damaged The warranty is void if the fire is used with the shelf not fixed in place by the screws Page 34 of 62 Commissioning Continued Check the Flue System e Turn the appliance to the maximum setting full rate Leave the appliance for 10 minutes and then test that all the products of combustion are entering the flue by traversing the perimeter of the fireplace opening or canopy using a smoke generator e g smoke matches If the appliance passes this test then it can be signed off If the test is failed leave the fire for a further 10 minutes and test again If it still fails disconnect the gas and do not use the appliance until the problems with the chimney flue liner have been rectified Complete the Installation Complete the commissioning sheet on page 36 e
2. 3 Class 1 Chimney YES 100cm2 The FR1500 is CE approved for installation in the following European Countries with I2H Gas 20mBar AT BG CH CZ DK EE ES FI GB GR HR IE IT LT LV NO PT RO SE SI SK TR FR1500G is a special version of the fire with a glass panel at the top to give the fire the appearance of a larger opening size however the actual opening is 175mm This version must be specified when ordering Page 5 of 62 Unpacking the Appliance Carefully examine the carton for damage before proceeding Ifitis obviously damaged please contact supplier to discuss whether to proceed Please check your delivery note Any missing parts must be notified within 48 hours of delivery and prior to installation If the carton is undamaged remove the gas fire from the packaging and examine its general condition If satisfied by the condition proceed with the installation Please note no claims will be accepted for any damaged components once the appliance has been installed Read this installation booklet fully before starting to install the appliance Special note should be taken to the different installation requirements of the two versions FR1500 and FR1500G Check the delivery paperwork and Data Plate inside the fire to confirm which version was purchased by the customer The installation should only be carried out by a GAS SAFE registered engineer and in accordance with national and local regulations
3. TOP VIEW FIREPLACE Page 20 of 62 Add the Plaster Board Ensure the materials used are fire retardant and in line with current building regulations FRONT VIEW SIDE VIEW PLASTER 20 mm PERSPECTIVE VIEW Page 21 of 62 Connecting the Gas If it has been refitted remove the vanity cover as shown below The gas line should now be connected to the 8mm inlet isolation valve with built in test point Once connected perform a drop test to ensure no leaks in the pipe work up to the gas appliance Remove the heat shield to gain access to the remote control unit so that the power switch put in the on position Vy 8mm Gas Inlet Vy E a gt a c A n Ji E QU EI M A Iw ES there must be 21mB to 19mB at this test point with the fire on Full Page 22 of 62 Once the heat shield is removed the remote control is visible Remove the Shield from the remote box and switch on the power To remove lhe heat shield take off lin the 2 x M4 nuts and washers gt TAT NOTE If the fire is operated without the s a Hm heat shield in place the remote control T is Had Hh will be eus de E aT J E 1b quu h iii pu Intr 2t T1 x UT iT HE dE Aum nd t efl Refit the remote heat shield pocket Refit the metal heat shield Read the section on lighting the fire and how to operate the remote control Read Page 48 The fire is now ready to b
4. Give the installation booklet to the customer e The customer should be shown in detail how to operate the appliance and the installation and user manual given to the customer e The customer must also be made aware that the appliance must be serviced every 12 months and that chimney or flue system should be checked regularly to ensure the appliance operates at optimum performance e The customer must be told not to block the room air vent e The warranty card is to be completed by the registered engineer who has commissioned the appliance This is to validate the warranty The card must then be given to the customer for postage back to the factory GAS ENGINEER FINAL SAFETY CHECK e Is the inlet pressure checked at the inlet point inside the fire within the 21mBar to 19mBar limits when the fire is on full Is the flue chimney operating safely Are the flue chimney and enclosure sealed Are all gas inlet holes in the burner tray sealed with metal tape Are all the heat shields fitted Is there a minimum of 100cm2 air ventilation Has the customer being shown how to operate the appliance Has the customer been shown how to replace the batteries in the handset and the main appliance If you have any questions or the gas fire is not operating correctly contact the manufacturer on 01325 327221 before you leave the installation If the appliance is to working correctly it should be disconnected from the gas supply until the problem
5. a handset to factory conditions to enable it to be paired with a new control hold the handset to unlock Press and hold the set button until handset beeps and release the set button The symbols at the top of the display will be flashing Press and release the mode button as necessary until the word SETUP is flashing in the top right corner Press and release the set button again to enter the setup menu Press and release the set button several times until CAO appears on the display CA means Cancel All Press and release the button once to change the display to CA1 Press and release the set button once more and the display will change to say the word TESC as shown in the image adjacent The handset is now free to pair again Step 2 Pairing the Gas Control with the handset This can only be done after the handset has been made free to pair as shown in step 1 above Ensure all the batteries are fitted correctly and with the power isolator slide switch on the TESC Fire control put in the I position eg ON Place the handset within 1 metre 3 feet of the gas fire Simultaneously press and hold the and buttons on the fire control WARNING the control in the fire not the hand set until the RED LED light on the gas control starts to illuminate Immediately as it does so press the power button on the gas control and the handset makes a noise and the display shows a symbol like a number
6. and pressure requirements of the appliance Ensure these are correct for the property supply This Fire has a battery remote control system and requires only the connection of an 8mm gas supply The remote is operated by a radio frequency remote system with handset All Spirit gas fires are given a 100 full function test at the UK factory before being shipped We record over 40 test settings to ensure the fire operates correctly and inline with the CE approval document There are no adjustable parts on this fire Never remove any wires from the black box or the remote system All connections are required DO NOT DISMANTLE THE FIRE AS IT WILL INVALIDATE THE WARRANTY Page 8 of 62 Remote Control System Take some time to learn about the remote system fitted to this fire The remote system features an RF radio frequency handset The handset and the remote black box must be matched together to work correctly Read the full section later in this manual to ensure you understand how the remote system works The handset with a screen will also show any error codes which occur Battery compartment cover opening lever White power isolator switch sliding Indicator light Decrease flame ee i Battery compartment cover Power Button The Handset is powered by 2 x AA batteries the Main remote system has 3 x AA batteries Always use high quality alkaline batteries to ensure a long life and reliable performance The batteries will l
7. and release the or button to toggle between C and F When the display shows the desired symbol press and release the SET button to store As the important settings above have now been done press and hold for a few seconds the SET button for a few seconds and this will exit the setup menu The control is now ready for use with the Fire Control Advanced settings Menu In the event that you may want to change the other preset settings of the control features Do not do a long press and hold above but a normal short press and release will take you into the advanced settings area Advanced settings options are e Back light o A Automatic default setting The back light comes on in the dark but not in the light o O Light never comes on o 1 Light comes on when ever handset is unlocked e Display contrast 8 levels from O to 7 default level 4 e P pairing with other devices other than the fire control The hand set can pair with other modules to o L Operate an electric light which is the dimmable in 9 steps o F operate an electric fan which can have 9 speed levels o A operate an auxiliary contact to operate another device Page 53 of 62 How to Find the Hand Set If you have misplaced the handset you can page it by pressing the button only on the fire control for around 5 seconds The handset will flash and make a noise to help you to locate it Once you pick up the TESC it knows you hold it and so th
8. for gas The installation must also be in accordance with relevant parts of local and national building regulations Failure to have the fire fitted by a qualified person nullifies ALL warranties and guarantees and may render the appliance dangerous For the Republic of Ireland reference should be made to IS813 and ICP3 and any guidance notes from Bord Gais FR1500 amp FR1500G Parts List Parts List e The Gas Fire is supplied as a Kit o Steel Enclosure with Gather o Front Vanity Cover Shelf o Gas Burner with Remote Control pre fitted o Instruction Booklet o Remote Control Handset e Optional Parts if ordered o Fascia Trim o Ceramics Logs or Pebbles o Manual Wall Switch See supplement o Convert from Battery to Mains Supply see supplement Page 6 of 62 Construction Dimensions FR1500 o 1503 1 80 1503 EXTERNAL E o 728 EXTERNAL 175 INTERNAL 120 50184 50 123 FR1500G EN lt r4 oc ud x uj co CN Ps 175 INTERNAL 120 50 269 50 1503 EXTERNAL Page 7 of 62 Gas Burner Construction Use the image below to review the burner construction taking note of the positions of the main components and the required connections The burner bar is pre fitted to the enclosure There is no reason why this should ever be removed Before starting to install the appliance review the Data Plate fitted to the appliance for the gas type
9. of the display Press and release the set button and this will put the control into Manual snooze mode The default time period for the snooze time period is 1 00 hour Pressing the set button again will show you the snooze time period remaining This can be adjusted by pressing the or buttons The timer period that can be set is from 1 minute to 4 00 hours After adjusting the time press set again to enter the time setting required or if left for a few seconds this time is now stored and used Once this countdown timer has reached zero the fire will turn off as if you had pressed off manually it does not recycle Snooze in thermostatic mode The same thing as above can be done before or during a thermostatic mode operation see below Page 56 of 62 Thermostatic Mode The handset has within it a thermostat sensor and this can be set so the fire will heat the room to match the temperature set in the handset Hold handset so that it unlocks then press and release the mode button several times as necessary until the display has a thermometer symbol flashing at the top of the display Press the set button to enter the selected mode Press the set button again to see the temperature setting that is set and the mode the default is 24 C and on the left of the display is a sun symbol showing it s the day temperature If a different temperature is required while the display is showing the current set temperature pres
10. the gas control is switched on switch in I position Step 4 Reverse the steps above ensuring all the heat shields and vanity cover are secured again Warning Ensure no wires or ignition lead is trapped under the heat shield as this will cause a fault The fire will now operate as normal Note If you are not intending to use the fire for a long period i e over Summer time months the battery life can be extended even more by sliding the white isolator switch to the left away from the On position symbol 0 Don t forget to switch it back on in the winter Page 58 of 62 Fireplace Ceramics If the fire has been supplied with ceramic logs or pebbles these must be installed in line with the instructions shown on pages 26 to 34 of this manual Only the ceramics supplied with the fire must be used Cleaning Instructions Before cleaning the appliance tum off the gas fire and allow it to cool for a number of hours Before using any cleaning materials test a small area first to ensure compatibility with the appliance finish We cannot be held responsible for damage caused by cleaning the appliance Remove the ceramics and place them in a safe place before starting to clean the gas fire Cleaning the Gas Fire Burner and Enclosure The most effective method of dust debris removal is achieved with the aid of a vacuum cleaner however great care must be taken to ensure that the pilot assembly is not touched Using a vacuum cleaner with a
11. 00G the gas fire requires an air vent within the room which will provide a minimum of 100cm2 free air in accordance with National Regulations In some countries additional ventilation may be required It is recommended that a guard be used for the protection of young children the elderly or infirm A qualified Gas Safe Registered engineer should service the fire at least every 12 months This will ensure the fireplace operates safely After installation the chimney should be inspected and swept regularly to keep the flue clear and free from debris and excessive build up of soot The fire needs to be covered up when work is undertaken to ensure the unit does not get damaged or gas outlets blocked Do not throw rubbish on the unit as this will render the appliance highly dangerous Due to the newness of the materials the fire may give off a slight smell for a period of time after commissioning This is quite normal and any odours should disperse within a few hours of operation Do not operate the appliance if decorating or using scented candles The particles will be drawn into the fireplace and burnt causing staining and further smells Page 11 of 62 BEFORE STARTING TO INSTALL CHECK 1 Gas Pipe Work is it strong enough to supply this high power appliance Did you check the flow rates as shown on page 5 2 Air Ventilation Make sure an air vent is installed in the room to provide fresh air from outside The air vent must supply a m
12. 0G is a Class 1 Chimney or 177 8mm flue liner of minimum 2 5m length The enclosure and flue must be sealed in line with building regulations This fire is approved for use with Natural Gas Only Once installed all additional gas inlet holes in the enclosure must be sealed with metal tape to avoid flame reversal which will damage the remote Page 10 of 62 It is important that the gas supply is disconnected before any old existing surround and hearth is removed The gas connections must be in accordance with National Regulations An isolation valve or valves has to be fitted adjacent to the appliance which when closed allow s the complete burner and control assembly to be disconnected for maintenance or repair in accordance with National Regulations This is supplied with the fire The pilot light and flame sensing device fitted to this fire is also an atmosphere sensing devise If for any reason any part of the pilot assembly is to be replaced ALL the assembly including the pilot burner thermocouple electrode and injector must be exchanged complete for an original manufacturer s pilot assembly only This atmosphere sensing devise is not adjustable and must not be put out of action The pilot light shuts off both the main burner and pilot if evacuation of the combustion products is interrupted If the fire shuts itself off do not use the fire and have the flue and fire checked by a suitably qualified person The FR1500 amp FR15
13. 5mm overall opening height then it must be installed with the glass panel as shown above The fire must never be operated without the glass in place If the glass is damaged a replacement must be purchased from the manufacturer Page 3 of 62 Read This First Burner Ventilation There is a 5mm gap between the shelf and the enclosure This is intentional and is used to provide burner air Do not block or seal this gap With the gap blocked the fire will overheat and switch off Any resulting damage is not covered by the warranty See instructions on Page 26 Gas Supply Do not install the fire until the gas pipework has been checked and a flow rate performed to ensure that the minimum flow rate specified in the technical section can be maintained when the fire operates on full Failure to do this may result in the fire failing the commissioning test or becoming unreliable This then may require removal of the fire and pipework to rectify the gas pressure Gas Flow Rate Natural Gas 1 019 m3 Hour Room Ventilation The FR1500 amp FR1500G requires a 100cm2 free air wall vent in the room in which it is installed Fascia Trim There is an optional trim which can be fitted to the fire Only a trim supplied by Spirit Fires is to be used Using a non standard trim will invalidate the warranty Gather The gather is an integral part of the fire that is required for the fire to function safely It is fitted at the factory and cannot be removed The
14. 7 back to back with a reverse number 7 Then within a minute hold the handset to unlock the keypad a green unlock light will illuminate when the handset has detected your hand The green light must be illuminated in this way for any of the command buttons to accept commands to operate the fire control While the display is as described and holding the handset as described press the SET button with the other hand to accept the pairing request to finish off the pairing of the handset to the Fire Control and to enter the setup the time of day on the handset as described in previous sections Page 55 of 62 N B If the display returns to the one shown above with the word TESC Shown then too much time has passed before pressing SET and so the handset has not paired yet Simply repeat pairing again N B Only ever press and buttons together when pairing handsets If done afterwards this will break the pairing made and a factory reset of the handset will need to be performed See Factory Reset of display handset later on in the instructions Snooze in manual mode Snooze mode is a time period you can set which will turn off the fire after a certain time period has elapsed The snooze time period can be set before or during manual operation of the fire Hold the handset to unlock as described previously and press the mode button as many times as necessary until the word MAN and the Zzz symbols are flashing at the top
15. SPIRIT FIRES PIN NUMBER 0558CQ1730 Rev 2 FR1500 amp FR1500G With ANTOSS Remote TECHNICAL MANUAL amp USER HANDBOOK CE APPROVAL BS EN509 2000 A1 2003 A2 2004 Serial Number nnn nnne For use with Natural Gas G20 Important It is recommended even if you have fitted these appliances before that you take the time to read through these instructions and follow them step by step Please quote this serial number when calling to discuss installation and spare part requests The Warranty is valid for 1 Year from date of delivery To register the appliance complete the warranty card supplied and return to Spirit Fires Limited 4 Beaumont Square Aycliffe Industrial Park Newton Aycliffe County Durham DL5 6XN This manual must be handed to the owner of the property once the appliance has been installed and commissioned Page 1 of 62 Page 3 Page 4 Page 5 Page 6 Page 6 Page 7 Page 8 Page 9 Page 10 Page 12 Page 24 Page 37 Page 38 Page 42 Page 43 Page 44 Page 45 Contents Description Read This First Technical Data Unpacking the Appliance Parts List Construction Drawings Gas Burner Construction Remote Control System Installation Requirements Building amp Installation Work Page 13 Brick Built Chimney Page 19 False Chimney amp Flue Liner Commissioning the Appliance Page 27 Fitting the Logs Page 34 Fitting the Pebbles Page 35 Final Safety Check List Page 36 Co
16. alled incorrectly it could be gas pressure or a faulty chimney that is causing the shutdown The pilot is a safety device which monitors the gas pressure and flue conditions If a fault in either of these areas are detected the pilot will not allow the fire to be lit Please review the installation conditions before proceeding DO NOT USE THE GAS FIRE UNTILA GAS SAFE ENGINEER HAS INSPECTED THE INSTALLATION The installation Should be checked step by step against this manual Page 38 of 62 Faults Hand Set Error Codes The handset will display an error code if a fault occurs Refer to the separate Sheet included with the manual for a full description of why the fire has failed Typical Faults amp Solutions pro Possible Cause and Solution Appliance clicks but Check spark lead is connected properly no spark or weak Check spark electrode is in the correct area and the gap correctly distanced to spark the pilot Check for a good spark Check the spark is in the right area Appliance sparks but does not light pilot Check that there is gas coming through by using a match Check that there is not air in the gas line purge the system No Gas fire does not Check isolation tap shut off is open light with match Check for blockages in the gas pipes Check for a good spark If there is gas but Check the spark is in the right area pilot does not light Check that the ignition lead is connected Ch
17. ast a minimum of 12 months or longer however it is advised to ask you gas installer to replace the batteries on each 12 month service The handset will switch the fire on off and regulate the flame up down The hand set has a child safe feature to avoid accidental lighting YOU MUST HOLD THE HANDSET IN THE PALM OF YOUR HAND TO SWITCH ON THE HANDSET THIS IS INDICATED BY A GREEN LIGHT ON THE RIGHT HAND SIDE Please read lighting the fire section later in this handbook before operating the appliance HELP IS AVAILABLE There are videos on YouTube that can be used to help you set up and use this remote system Search on YouTube for TESC GAS CONTROL and you will find a series of instructional videos on how to set up and use the hand set Page 9 of 62 Installation Requirements This gas fire is intended for decorative purposes The installation must be in accordance with National Regulations and must be carried out by a qualified Gas Safe Registered installer Building work should only commence after a thorough survey of the intended location of the impending installation has been completed and it has been established that the unit can be installed and operated without risk to the owner or tenants of the property or their neighbours This fire must be installed and used in accordance with these instructions Prior to installation ensure that the local distribution conditions identification of the type of gas and pressure and th
18. blem with gas supply has been rectified This could be the pipe work or the meter Page 36 of 62 Warning Fire Guards amp Hearths This appliance is not fitted with an integral guard In normal use consideration may be given to the use of a fireguard conforming to BS6539 or BS6778 so that the approach to the appliance is limited such that access to the flame is minimised It is recommended that a fireguard conforming to BS6539 or BS6778 is used for the protection of young children the elderly and infirm The installer is to advise the user not to stand too close to the appliance for prolonged periods of time and warn that loose clothing is particularly at risk of burning due to the presence of an unguarded flame In addition the installer is to advise the user against placing combustible material directly in front of the appliance Floor coverings such as carpets are considered to be acceptable For some countries a non combustible hearth must be fitted in front of the fire in accordance with National Regulations e g United Kingdom Page 37 of 62 Technical Fault Diagnosis amp Troubleshooting Every gas fire manufactured by Spirit Fires is tested at the factory and given a full 40 point performance check to ensure it operates correctly It is highly unlikely that when installed in line with these instructions that it would not operate as designed The most typical causes of problems during the initial phase after installati
19. cognised Keeping hold of a button when pressing unless otherwise instructed will not be recognised as a command press Lighting the Fire AN a e The handset should be showing a Wifi symbol in the top right of the display This means the handset is within range of the fire control box and can be used to light the fire e If the symbol is not there check o a the batteries in the handset and the fire gas control box are the correct way around o b the batteries are in good condition if in doubt fit a new set of alkaline batteries like Duracell o Cc that the small isolation switch on the gas control in the top left corner is in the ON position 1 and not the OFF position 0 e Grasp the handset in the palm of the hand and sides to unlock the child Safe mode The green unlock light will illuminate Keep the handset held to keep the control unlocked to enable operation of the buttons e Look at the image on the previous page to identify the power button With the other hand touch and hold a finger on the power button for about 3 seconds e There will be a short beep and the unlock light will flash e When the word pilot appears at the bottom left hand corner of the display immediately release the power button e There will be a second flash of the unlock light and a longer beep e The fire will start the ignition sequence and start within a few seconds e Warning If power button is held for more than a few seconds aft
20. e SETUP menu Here you can change the clock from 12 hr or 24 hour format the day of the week hour of the day minute of the day and the display in Celsius or Fahrenheit To navigate through the menu set moves to the next parameter and Mode move back to the previous parameter and change the display parameter PROG SETUP Settinq the display for 12 or 24 Hour displa Hie The H indicates that it is time to set the timer to either 24 hour display or 12 Hour AM or PM display Press the or button on the handset to toggle between the two settings When you are ready to confirm the setting you want press the SET button to progress to setting the day of the week Setting the day of the week Press and release the and buttons until the correct day of the week is shown on the display Mo Monday Tu Tuesday We Wednesday Th Thursday Fr Friday Sa Saturday and Su Sunday Press SET to accept the day of the week and to progress to setting the Hour of the day Note Whilst doing this setup pressing SET advances to the next display and pressing MODE will return you to the previous display setting Page 52 of 62 Setting the Hour Press and release the or button to change the hour to the correct hour and press set to store and to move to setting the minute Repeat this for setting the minutes Setting the temperature display to Celsius or Fahrenheit Press
21. e 19 Installing within a Brick Chimney Preparing the Fireplace Opening WALL CUTOUT FRONT VIEW de D o I El 3 E E The above image shows the minimum fireplace opening width and height Page 13 of 62 The image shows the fireplace opening required to install the fireplace unit The gather is fitted to the fire and cannot be removed hence there is a larger opening height WALL CUTOUT SIDE VIEW Above shows the minimum depth of the wall and the maximum lintel size when fitting the fire to allow the spigot on the gather to line up with the chimney Add 20mm to this for the front face of the finished wall plaster board The enclosure can be deeper however any voids should be filled otherwise there is a risk of banging when the enclosure expands and contracts with heat Inserting the Fireplace into the Opening Once the fireplace opening has been created the appliance can be lifted into the opening Feed the gas pipe through the chosen hole into the lower burner area ready for connection later Before the gas pipe can be fed into the enclosure the vanity cover must be removed Ensure that this is stored in a safe place with the screws See image blow in how to remove the vanity cover Page 14 of 62 Fireplace Clearance FRONT VIEW Lu O lt Lu es lt MINIMUM CLEARANCE The fire must sit forward 20mm from the brickwork This is for the plasterboard that will be added later to fi
22. e adjustment of the appliance are compatible Clearances between the fire and all combustible materials must conform to National Regulations The builders opening or fireplace opening must be constructed of a non combustible material For some countries a non combustible hearth must be fitted in front of the fire in accordance with National Regulations e g United Kingdom Before the fire is installed a flue test in accordance with National Regulations should be carried out Any flue damper plate or flue restrictor must be removed or fixed permanently in the fully open position or shall only be fitted in accordance with National Regulations Where existing chimney systems are to be used in conjunction they should have been swept and undergone thorough examination to ensure that they are in a sound and safe condition as well as providing an adequate draw when the gas fire unit is in operation A simple smoke test will reveal whether or not the chimney is working correctly If the chimney has been used with a solid fuel appliance in the past it must be swept before the appliance is installed The unit must not be installed unless the chimney flue length is at least the distance indicated on page 5 minimum flue height The fire and flue system should be checked regularly to ensure that it is free from obstruction Check gas pipe work to ensure the correct flow rate for the appliance The minimum flue requirements for the FR1500 amp FR150
23. e commissioned Page 23 of 62 COMMISSIONING THE APPLIANCE WARNING The burner inlet flow rates are factory set and cannot be changed The aeration is fixed do not change the burner aeration This fire must not be operated without the heat shield in place over the remote system Failure to do this will result in serious damage to the remote system which will not be covered by the warranty The burner is tested to 150mBar at the factory to ensure there are no gas leaks in the burner Do not adjust any fixings within the fire Refer to the lighting the fire on page 48 later in this handbook to learn the remote system and sequence To commission the appliance complete all of the steps below CHECK THE GAS PRESSURE Use the commissioning sheet on page 36 completing each section in turn recording the gas pressures measured on the sheet It is very important that this test is performed as stated to ensure the appliance is safe and reliable Ensure the gas tap is in the open position to allow gas to flow Remove the screw from the test point within the appliance and connect a manometer With the appliance off check for gas soundness in the Supply circuit If there is a pressure drop correct the leak in the pipe work before continuing Check 1 Record the standing pressure in the commissioning sheet Using the handset start the fire The pilot will light and then the main burner will ignite If the pilot does not light try a few t
24. e is not covered by the warranty Remote Control Components The remote control used on this fire has only a small number of components to function a A black remote box gas control valve b An ignition lead c A Pilot Assembly d A Hand Set The remote is built to the latest standards and is new to the UK market Take some time to review the lighting procedure and learn about the operation of the remote Remote Control Error Codes If a fault occurs the handset will show an error code Use the attached sheets to learn about the codes and how to rectify the fault displayed To reset the error press the power button on the handset and it will return to normal operation Page 41 of 62 Service and Aftercare Requirements Every 12 months the gas fire unit should undergo a regular service this work Should be carried out by a Gas Safe registered engineer only The annual service of the unit must be performed in line with the instructions in the manual Refer to the enclosed technical installation and operational manual amp the remote control instruction document When carrying out the annual service the Gas Safe Engineer should examine and verify the following Ensure the pilot assembly is clean and operates safely Ensure the injector is clean and fitted correctly Ensure the burner aeration is as per the manufacturer s instructions That the gas fire burner unit correctly cross lights within 10 seconds A pressure drop
25. e sound stops The flashing and sound will last for 60 seconds each time the handset is paged as described If not found in 60 seconds page again and so on NOTE PRESS Button ONLY NOT and Together as you will accidentally break the handset pairing and have to reset handset to factory state and pair again see other parts of the booklet if this happens Pairing the Handset WARNING There should be no reason to do this with a new or working fire as the pairing has been done at the factory This is only to be used in the event of fitting a new control box or using a new handset Using these instructions on a new fire will erase all of the factory settings If you are experiencing difficulty using the handset on a new fire we suggest reading the above instructions again or using the YouTube videos DO NOT USE THESE INSTRUCTIONS ON A NEW FIRE OR WORKING FIRE If either the handset is reset or the gas control has the pairing operation buttons operated the current pairing will be broken and both the two operations below will be required to be done to enable a new pairing to be set up This will need a gas engineer to enter the gas controls inside the fire Page 54 of 62 Use these instructions to Pair the handset to the fire gas control inside the fire READ WARNING ABOVE BEFORE PROCEEDING Step 1 Factory Reset of display handset This needs to be done first to enable the handset to be paired again To reset
26. eck the pilot gas slot is clear Check the pilot flame is heating the thermocouple replace pilot Pilot lights but does Check that the thermocouple is working replace pilot not light main burner Check that the gas pressure is strong enough Connect a manometer and listen for the main burner opening if the gas pressure drops there is a blockage or the pipes are not big enough Check that the gas pressure is strong enough Connect a manometer and listen for the main burner opening if the gas pressure drops there is a blockage or the pipes are not big enough Burner lights but Check for chimney draw or downdraft causing pilot to go out Safety Device turns off after a few operating minutes Check ventilation is not too strong and the flame is not blowing off the thermocouple Check gas pressure is correct and maintained at constant level especially with other appliances in the home working The handset shows a code EXX when there is a fault Use the chart to trace the Hand set Error Codes fault If you do not have the chart call 01325 327221 to request a copy Do not start dismantling the gas fire as further damage will be done Page 39 of 62 Pilot Assembl ODS There is a highly sensitive oxygen depletion sensor designed into the pilot light If any part is damaged the entire unit must be replaced Do not attempt to bend or alter the flame head thermocouple or aeration hole Use only genuine Spare parts as si
27. ect the pressure gauge replace the pressure test point sealing screw and test the appliance for gas soundness Refit the front shelf Page 25 of 62 Warning Front Shelf amp Burner Ventilation C The front shelf when fitted correctly has a small 5mm gap below it to allow air into the burner tray DO NOT BLOCK THIS SLOT OR SERIOUS DAMAGE WILL OCCUR TO THE REMOTE SYSTEM Once the shelf is correctly fitted Fit the Ceramics to the Fire The fire can be operated as a Ribbon Flame Only or either Fireplace Logs or Pebbles depending on the customer purchase order If in doubt before proceeding check with the customer which version was purchased Warning Only the ceramics supplied with the fire can be used The ceramic logs and pebbles must be positioned on the burner as shown in the following set of images Page 26 of 62 FR1500 Log Set Layout 19 Piece Set Page 27 of 62 Add Log 3 riam Page 28 of 62 Add Log 8 Add Log 6 ZI O dd A O a il w NEL NL NE md mi mae e dll iln mesa lt Page 29 of 62 Add Log 5 Ceramic Wool using latex gloves make the ceramic wool into strands and place this on the burner bar This will create a sparkling effect when the burner is lit Page 30 of 62 Add Log 4 Page 31 of 62 Add Log 14 Page 32 of 62 FINAL LAYOUT LEFT HAND SIDE RIGHT HANDSIDE Page 33 of 62 FR1500 Pebble Set Layout 45 pebbles
28. er button and hold for 1 second then release The burner will then light within 10 seconds and adjust automatically to the maximum power setting The power of the burner can then be adjusted up and down by pressing the and buttons never press the buttons at the same time or the fire will lose its memory and need setting back to the factory settings Page 57 of 62 Replacing the Batteries Handset Batteries To replace the handset batteries open the cover on the back of the handset Remove the old batteries and using the diagram on the inside of the cover fit new high quality alkaline batteries Main Appliance Batteries These are inside the gas fire body To change the batteries involves removal of the vanity cover and heat shields It is strongly advised to leave this task to a gas safe engineer to perform The best time to change the batteries is during the annual service of the fire Step 1 Remove the vanity Cover by removing the four cross headed screws see page 14 Keep the screws safe for refitting after the batteries have been replaced Step 2 Remove the heat shield by removing the two cross headed screws Ensure that none of the gas controls or parts are disturbed during this process Step 3 Remove the battery cover from the gas control Remove the old batteries and using the diagram on the inside of the cover fit new high quality alkaline batteries Ensure the batteries are positioned correctly and
29. er the second flash beep amp the word pilot appears the command is ignored for safety reasons Similarly if it is released too soon before the word pilot appears the command is also ignored This is a safety feature built into the system to ensure the fire only lights when it is intended to by the user Page 50 of 62 Adjusting the Flame e Grasp the handset in the palm of the hand and sides to unlock the child Safe mode The green unlock light will illuminate Keep the handset held to keep the control unlocked to enable operation of the buttons e Look at the image on the previous page to identify the amp buttons e Using your other hand press the buttons to decrease and increase the flame Look at the screen on the handset and it will show the current state of the flame between Max and Min Switching the Fire Off e Grasp the handset in the palm of the hand and sides to unlock the child safe mode The green unlock light will illuminate Keep the handset held to keep the control unlocked to enable operation of the buttons e Look at the image on the previous page to identify the power button e Using your other hand press and release the power button and the fire will switch off NOTE The following operations can be seen on YouTube You Tube use your internet browser to visit YouTube page and within YouTube search for TESC GAS CONTROL Setting Up The Handset The handset comes paired to the black box so does n
30. gather has a 180mm Spigot If installing the fire in a brick built chimney without a flue liner the spigot must be sealed to the chimney Flue System The FR1500 AND FR1500G requires a Class 1 or 180mm flue of minimum 2 5m length Flame It is normal with this type of appliance for the flame to be directed towards the back of the enclosure This will be worse where the fire is installed without the official gather and with a longer flue Remote Heat Shield This fire is approved with the heat shield in place The fire should never be operated without the heat shield any resulting damage caused by heat is not covered by the warranty Page 4 of 62 Technical Specification Important Note This fire is available in two versions Please check the paperwork and data plate on the fire to confirm which version has been purchased Read the description on page 3 MODEL FR1500 FR1500G Gas Type Natural Gas Gas Category I2H Gas Type G20 Inlet Pressure mbar 20 Countries of Destination See Table Below Gas Valve Control Unit TESCO1 RF 868 15 TESC Setup Code 228407 Remote Transmitter Type RF868D Stereomatic 600 x 2pc AC061 ERTA PG 82 650 AC012 10 766 1500 w x 265 Enclosure Opening mm nue hry UN h x 317 d see note below Mimimum Flue 177 8mm diameter with 2 5M length or Class 1 Requirements Chimney Using Flue Liner Minimum Chimney Requirements Room Air Vent Required Room Vent Size free air Co
31. ill be requested to provide both the serial number of the fire and gas safe registration number of the person who will carry out the repairs The serial number is shown on the data plate Call 01325 327221 and ask for Customer Services to order spare parts We can email a set of images to confirm the parts required The only user replacement part for this gas fire is the remote handset All other parts must be fitted by a trained gas engineer The fitting of replacement parts must be carried out by a qualified Gas Safe Engineer in line with current regulations To change parts refer to the servicing section of this manual Warning Fire Guards amp Hearths This appliance is not fitted with an integral guard In normal use consideration may be given to the use of a fireguard conforming to BS6539 or BS6778 so that the approach to the appliance is limited such that access to the flame is minimised It is recommended that a fireguard conforming to BS6539 or BS6778 is used for the protection of young children the elderly and infirm The installer is to advise the user not to stand too close to the appliance for prolonged periods of time and warn that loose clothing is particularly at risk of burning due to the presence of an unguarded flame In addition the installer is to advise the user against placing combustible material directly in front of the appliance Floor coverings such as carpets are considered to be acceptable For so
32. imes until any air in the gas pipes has been purged Use the handset to ensure the fire is on full You will now start a set of tests which will confirm the gas pressure is within the safety limits The inlet supply pressure measured at the test point in the fire must be within 1mb of the pressure stated on the Data Plate For example a 20mBar Natural Gas appliance must read between 19mbar and 21mBar Check 2 with the fire on full and all other gas appliances in the home on record the pressure in the commissioning sheet Check 3 with the fire on full and all other gas appliances in the home off record the pressure in the commissioning sheet Are the results within the limits Page 24 of 62 i 7 lt X z a gt 8mm Gas Inlet SS ve 1 E SE E LE o Es N NY Wiis amp A E A To Commission this appliance there must be 21mB to 19mB at this test point with the fire on Full aS 4 gt bes Q hs e En MO em A s hos dre is ax X y is q ag 3 IF THE TEST IS FAILED If it is not possible to maintain the pressure at the required level the problem may be caused by blockages in the pipework incorrect pipe sizing or a faulty meter If the problem is the meter then TRANSCO BORD GAIS or the propane supplier must be called to adjust the governor Do not use the appliance until the issue is rectified IF THE TEST IS PASSED Disconn
33. inimum of 100cm2 air in to the room Check with the vent supplier Spirit Fires can supply a high quality air vent with baffles Call sales on 013254 301020 3 Chimney Does the chimney or flue system meet the minimum requirements as set out on page 5 Has the chimney been swept and checked for leaks Building and Installation Work Gas Supply Consult the Data Plate within the appliance to ensure the correct gas type and pressure is available within the property Before commencing to create the fire opening for the inglenook unit note that a gas supply is required The gas supply pipe should run into the installed enclosure from either the rear left or right hand sides the gas supply is best run through the right side of the enclosure CHECK GAS SUPPLY RATE BEFORE INSTALLING SEE PAGE 5 The fire has an 8mm inlet via an isolation valve The fire also includes a pressure test point elbow to test inlet pressure The gas pipe work should be routed into the enclosure via the available access holes If the gas pipe work is over 1 5mtrs in length it is recommended that the pipe work is increased in diameter from this point to 15mm 22mm and possibly 28mm depending on the length to the meter see technical section for gas consumption This will ensure a stable gas supply Building Work It is important that the gas supply is disconnected before any old existing surround and hearth is removed Measuring from the floor surface the intended locat
34. ion of the base of the enclosure unit is marked onto the wall Allowances must be made for the steel gather if required The enclosure should be located centrally to the existing flue chimney at your desired height If the fire is not placed central to the chimney the flame picture may pull incorrectly The area indicated on the wall must be removed to house Page 12 of 62 the Fire enclosure and burner unit In some installations it may be necessary to install a small lintel above the opening if so an allowance must be made to accommodate this lintel The Fire does not have its own lintel After removing the excess brickwork to the required height the base of the fire opening which the Fire burner and enclosure will sit upon has to be built To create a seal around the appliance and allow correct operation of the flue the original fire opening must be closed using bricks or blocks infill the void around the enclosure using block work or rubble It is advisable to install a solid base inside the fire opening to sit the steel framework supporting the burner unit on to Installation Style The fire is supplied with the gather fitted this must not be removed The fire can be used within an existing chimney fireplace opening or within a new build with a false chimney breast Choose the correct installation method as shown below 1 Within a Chimney Fireplace Opening See Below 2 In a New Build with False Chimney Breast Go to Pag
35. is interrupted The most likely cause is a blocked chimney If the fire shuts itself off restart the fire following the procedure in section Lighting the fire on page 48 If the fire continues to shut itself off do not use the fire and have the flue chimney and fire checked by a suitably qualified person The pilots ODS Oxygen depletion sensor must not be put out of operation The user must not adjust the pilot If any of its parts are damaged and need to be exchanged the original manufacturers parts must be used Page 47 of 62 Lightina Adjusting the Fire The appliance is supplied with an internal battery power supply and is operated via a handset There are 3 x AA batteries inside the appliance and 2 x AA batteries in the handset Only use good quality alkaline batteries to ensure a long life from the handset and remote box The handset comes already paired to work with the fire and the time set etc Please read these instructions carefully and watch the instructional youtube video through your internet web browser if necessary Do not try pairing the handset thinking that it is not paired it is more likely the handset is not being pressed correctly If the main burner or pilot light is extinguished during lighting do not attempt to re light the pilot within three minutes uick Start User Instructions NOTE The following operations can be seen on YouTube You Tube use your internet browser to visit YouTube page and wi
36. is rectified If the appliance is not fitted in strict accordance with these instructions Spirit Fires cannot be held responsible for any damage caused and reserve the right to charge for any corrective work Page 35 of 62 Commissioning Checklist This product is guaranteed for 1 year from the date of delivery as set out in the terms and conditions of sale This guarantee will be invalid to the extent permitted by law if the above Commissioning Checklist is not fully completed by the installer Installation CompanYV sr eereierrrereeeeenerrrereeaaaacrreereaaa nennen Engineer Contact No Gas Safe Number Date of Installation M00 ret mta Flue is correct for appliance Flue Flow test Spillage test Gas soundness amp let by test Standing pressure test appliance off 3 Appliance working pressure on High Setting with all other gas appliances in the house operating on full 4 Appliance working pressure on High Setting with all other gas appliances in the house mBar switched off 5 Does ventilation meet appliance requirements To pass the commissioning test the fire must have the correct inlet pressure when measured at the test point that is supplied within the fireplace The pressure reading with the fire operating on full must be within the limits of 21mB to 19Mb If the appliance does not pass this test it should be disconnected from the gas until the pro
37. mbly for a gt good strong flame Ignition e The fire must now be leag commissioned following all the steps set out on page 24 Spare Part Component List Code Fire Parts Parts AC061 Injetor ING 600 2 YES NO GC022 Ignition Lead HT380 1 YES NO Ordering amp Fitting Spare Parts When calling to order spare parts you will be requested to provide both the serial number of the fire and gas safe registration number of the person who will carry out the repairs The serial number is shown on the data plate Call 01325 327221 and ask for Customer Services to order spare parts We can email a set of images to confirm the parts required The only user replacement part for this gas fire is the remote handset All other parts must be fitted by a trained gas engineer The fitting of replacement parts must be carried out by a qualified Gas Safe Engineer in line with current regulations To change parts refer to the servicing section of this manual Optional Extras There is an option to add a wall switch and to upgrade to a mains power supply These parts must be ordered from customer services The work must be carried out by a trained gas safe engineer with electrical qualifications Page 44 of 62 Ss E 2 A quai PIN NUMBER 0558CQ1730 Rev 1 FR1500 amp FR1500G With ANTOSS Remote USER HANDBOOK Serial Number nnn nnne For use with Natural Gas G20 Please
38. me countries a non combustible hearth must be fitted in front of the fire in accordance with National Regulations e g United Kingdom Page 60 of 62 WARRANTY INFORMATION This appliance is supplied with a 12 month warranty from the date of delivery The Warranty covers defective parts only and does not cover typical wear and tear that occurs with a gas fire appliance This gas appliance carries full CE approval and has a long and reliable history The fire is given over 40 function tests during the manufacturing process and is fully working before being shipped If installed correctly in line with these instructions the fire will have a long and reliable life If the appliance develops a fault refer first to the fault diagnosis section earlier in this booklet for possible causes If the fire has been recently installed recall the gas engineer to check the installation again in line with the requirements of the book We will not accept any claims where the gas fire has been dismantled or the burner wiring or connections have been tampered with In order to make a warranty claim you will be required to e Supply the serial number of the appliance as shown on the front of this booklet and on the data plate within the fire e Supply full details of the GAS SAFE engineer who installed the appliance e We may also request a copy of the installation receipt Failure to supply details of the Registered Engineer who installed the appliance will i
39. milar looking parts from other appliances may well give different or inferior performance and could lead to a hazard Spark Ignition Failure The gap between the pilot electrode and the pilot should be 3 5 4 5mm and normally adjustment is not necessary the electrode is very brittle The spark should jump across the gap between the electrode and the gas outlet on the pilot head If the ignition fails a lighted taper or match can be inserted into the pilot area to check that gas is reaching the pilot If the pilot lights using a taper or match then check the ignition lead has not become detached or the pilot gap is correct If the problem still exists replace the pilot assembly Page 40 of 62 Burner Flame The flame on this type of appliance is normally directed towards the rear of the enclosure This is normal due to the opening size and flue system The flame will never stand upright It is to be expected that over time the surface on the rear of the enclosure will tarnish This is typical wear and tear for a gas fire If the flame is drawn under the shelf this highlights a serious installation fault and the appliance must not be operated until the cause of the flame reversal is found A typical cause would be unsealed burner holes failure to seal the enclosure and flue downdraft on the flue system or incorrect flue system If the fire is operated with flame reversal the remote will be damaged and any resulting heat damag
40. mmissioning Sheet Fire Guards amp Hearths Technical Fault Diagnosis amp Troubleshooting Page 39 Hand Set Error Codes Page 39 Typical Faults and Solutions Page 40 Pilot Assembly Explained ODS Page 40 Spark or Ignition Failure Page 41 Burner Flame Page 41 Remote Control Parts Service and Aftercare Requirements Servicing Instructions Spare Parts Components List Gas Fire User Instructions Page 2 of 62 Description of FR1500 Design This appliance is supplied as a complete suite of gas fire burner unit enclosure and fascia To comply with the approval this fire must be installed as designed There are two versions which can be purchased depending customer preference Check the data plate to confirm which version is to be installed The versions are e FR1500 This is the standard version of the fire with an overall opening size of 175mm H x 1500mm W e FR1500G This is a special version of the fire which has a larger opening height of 265mm This is then reduced down to 175mm by the addition of a glass panel This glass panel is an integral part of the fire and is fitted at the factory If it is broken it must be replaced before the fire can be used FR1500G THIS GLASS PANEL IS FITTED AT THE FACTORY AND MUST NOT BE REMOVED IF THE GLASS IS DAMAGED A REPLACEMENT MUST BE SOURCED FROM THE MANUFACTURER BEFORE USING THE GAS FIRE Refer to the Data Plate If an FR1500G version is ordered with the larger 26
41. mponents on this fire Servicing Procedure e Turn off the gas fire and allow time for it to cool e Remove the vanity cover as shown on page 14 e Turn off the gas supply at the Sod en dics within the LUN e INJECTOR Use a 15mm cxt risu do il vv Mi spanner to remove the gas pipe from the injectors Using a mm Ensure the spanner loosen the screws on the E 3 40 eration hole injector bracket and lift the UE E smt E injector bracket off the venturi bolts When 0 ini 2 replacing ensure E tube Clean the injector and Eita remove blockages Do not use a between the E two plates needle or wire as this will ISTE damage the injector Clean any debris from around the aeration hole Reassemble the injector and connect the gas pipe e PILOT ASSEMBLY To ensure a long reliable life it is advised to change the pilot when servicing the fire This can be done by disconnecting the gas supply ignition lead and connections to the remote Use the image below to ensure the correct connections are made on the remote black box If the pilot is not being changed then make sure the pilot sy i ddiin ae N journals are clear and free from x cie penas dirt X EIN e BURNER Using a soft brush or Page 43 of 62 vacuum cleaner carefully remove any debris from the burner unit e FINAL STEPS Re assemble the fire in the reverse order and re connect the gas supply and check for leaks e Check the pilot asse
42. nish the installation and create a letterbox style Position the enclosure in the opening so there is a minimum clearance of 10mm on each side and 10mm at the top This allows minor adjustment This void should be sealed with a suitable fire retardant material to seal the enclosure to the opening Once installed in the opening the fire must be fixed down to the fireplace opening using screws and plugs This can be done by removing the vanity cover and drilling through the base Take care not to damage the connections or gas pipes while drilling Page 15 of 62 SECTION VIEW The above shows the fire correctly positioned spigot in line with the chimney The enclosure must sit 20mm forward of the brick wall to allow for plasterboard to be added See image above Note The FR1500 and FR1500G are supplied with the gather fitted and sealed to the enclosure This gather must not be removed or modified in any way The gather is an integral part of the structure of the fireplace design Page 16 of 62 With a Flue Liner within a Brick Chimney SECTION VIEW The flue liner must comply with the minimum size as specified in the technical section on page 5 The liner must be sealed to the spigot Once the fire is fixed in place the void above the fire must be filled in as shown below ready to be finished with plasterboard to create the final look required SECTION VIEW Page 17 of 62 Complete the Installation by adding plasterb
43. nvalidate the warranty To register your appliance please complete and return the warranty card supplied with the fire To raise a warranty claim call Customer Service on 01325 327221 We may send an independent gas engineer to site to first inspect the installation IMPORTANT NOTE Heat Damage This gas fire must never be operated without the heat shields in place over the Black Box Failure to do this will result in serious damage to the remote system We will not accept any warranty claims for melted remote system The fire was tested at the CE test house to ensure that during normal operation no parts become hot or damaged If heat damage has occurred it highlights a very serious issue over the installation of the appliance In the instance of the remote system becoming hot enough to melt it highlights an install fault not a component failure Typical causes are using the fire without the heat shield incorrect burner ventilation unsealed enclosure an unsealed flue system or flame reversal Before purchasing any new parts to repair the fire the cause of the melting must be rectified Page 61 of 62 ONLY USE GENUINE REPLACEMENT PARTS Spirit Fires Ltd 4 Beaumont Square Aycliffe Industrial Park Newton Aycliffe County Durham DL5 6XN T 01325 327 221 F 01325 327 292 WWW Spiritfires co uk sales spiritfires co uk This revision is dated on the 22 12 2014 The information supplied in
44. oard SECTION VIEW PLASTER 20mm FIREPLACE PLASTER 20mm FRONT VIEW The gas can now be connected and the fire commissioned Go to Page 22 Page 18 of 62 Installing in a New Build with Flue Liner The gas fire can be installed in a new build property that does not have a built chimney This requires the fire to be connected to a flue liner and a false chimney breast built around the fireplace to complete the final letterbox look If considering this installation method consideration needs to be given to clearances to combustible materials The Firebox Gather and Flue Pipe will get very hot Check building regulations for guidance Choose Installation Location The firebox must be located on a flat even surface which can support the weight of the fire and the flue liner A breeze block wall should be built for this purpose Ensure there is a clearance of 20mm at the front of the wall for the final plasterboard SIDE VIEW FIREPLACE FRONT VIEW PERSPECTIVE VIEW FIREPLACE Page 19 of 62 Connect the Flue Liner Ensure the liner meets the minimum requirements of the fire see page 5 Itis likely that with this style of installation the flue liner should be insulated Contact your flue supplier for advice FRONT VIEW PERSPECTIVE VIEW PIPE ADDED Build the Stud Wall Ensure the materials used are fire retardant and in line with current building regulations MINIMU ARANCE WALL MINIMUM ET ERRANCE
45. on are incorrect gas pressure and flue system requirements If experiencing problems go back to the installation section and check the install step by step The gas pressure must be tested using the test point inside the fire and when operating on full and ALL other gas appliances in the home are running also it must read between 21mBar and 19mBar Outside of these limits the fire will shut down and be unreliable even dangerous Do not use the fire until the gas pressure problem is solved If the problem is the chimney have a smoke test performed to ensure it is not blocked or there is severe down draft occurring If the commissioning procedure is not followed and the fire is left to run with the wrong gas pressure the fire will Fail to light Light for a few seconds Shut down unexpectedly Have a low flame Have a yellow flame Cause sooting in the enclosure a ul Rh WN he Other areas to check during installation are Has the pilot been knocked and the gap too large Are you using the handset properly see YouTube for videos Are the batteries fitted properly Is the magic eye positioned correctly Is the flue operating correctly without reverse drafts or air leaks ul BR WN E Unexpected or Sudden shutdown If the appliance shuts down unexpectedly it highlights a fault with the installation If the appliance will light again within a few hours it confirms that the appliance is working but is inst
46. ot need setting up on a new fireplace Use this section to adjust the handset settings and to set up the other functions We advise not adjusting the handset until you are comfortable with using the handset and are able to switch the fire on off easily Using the YouTube videos will resolve most issues to do with lighting and setting up the fire as the process is shown visually Battery Condition Display The legend at the bottom of the screen shows the battery condition of both the batteries in the hand set and in the fire control unit RC Remote Control handset FC Fire Control Box inside fire If the batteries are exhausted the fire will not work To get the best performance from your fire we recommend using high quality alkaline batteries and we suggest these are replaced by your gas engineer each year during the annual service N B Pairing is not lost even if the batteries are removed or flat Page 51 of 62 Setting the Time Should you have to set the time or change the time you need to enter the SETUP menu Hold the handset to unlock the keypad and keep held throughout the following steps if you release too soon the menu will exit and you will have to start again Press and hold set for several seconds The symbol in the top centre will flash Press and release the mode button several times until the word SETUP appears flashing in the top right corner of the display Press and release set again to enter th
47. quote this serial number when calling to discuss installation and spare part requests The Warranty is valid for 1 Year from date of delivery To register the appliance complete the warranty card supplied and return to Spirit Fires Limited 4 Beaumont Square Aycliffe Industrial Park Newton Aycliffe County Durham DL5 6XN This manual must be handed to the owner of the property once the appliance has been installed and commissioned Page 45 of 62 Page 47 Page 48 Page 57 Page 58 Page 59 Page 59 Page 60 Page 60 Page 61 Page 62 Contents General Information Start Shutdown Instructions Using the Manual Switch Panel Replacing the Batteries Cleaning Instructions Fireplace Ceramics Replacement Parts Fire Guards and Hearths Warranty Information Contact Details Page 46 of 62 General Information A qualified GAS SAFE registered installer is required to fully install the appliance failure to do this may render the appliance dangerous and will invalidate the warranty This fire is intended for decorative purposes Any purpose provided ventilation should be checked regularly to ensure that it is free from obstruction The fire should be serviced regularly by a qualified person The chimney should be swept before the appliance is installed and should be swept and inspected regularly to ensure that all of the products of combustion are entering the flue and there is no excessive build up of soot Once the flue and fire unit
48. rol unlocked to enable operation of the buttons Then with the other hand touch and hold a finger on the power button for about 3 seconds A short beep and a flash of the unlock light will happen upon touching When the word pilot appears at the bottom left hand corner of the display immediately release the power button A second flash of the unlock light and a longer beep will also sound at the time to release the power button The Fire should be lit within a few seconds N B If power button is held for more than a few seconds after second flash beep word pilot appears the command is ignored for safety reasons Similarly if it is released too soon before the word pilot appears the command is also ignored With this system the control has been designed to ensure that only intended ignition of the fire occurs To stop the fire hold the handset so that it unlocks press then release power button Page 49 of 62 Ensure the power isolator switch on the front corner of Fire Control Black Box within the Fire is in the on position 1 Note The handset has a child safe function To unlock the handset you must grasp the handset in the palm of your hand The green unlock light will illuminate to show when the handset is unlocked and ready to accept commands N B Keep a grip of handset to keep it unlocked to continue to operate the command buttons For safety reasons a button must be pressed and released for the command to be re
49. s have been checked and remedial action taken the fire is ignited in the manner depicted in section Lighting the fire see page 48 This fire should be checked regularly to ensure that it is free from obstruction Do not throw rubbish et cetera upon the burner surface area or otherwise disturb the fuel bed Debris from any source or soot formed should be removed from time to time see Cleaning instructions see page 59 Due to the newness of materials the fire may give off a slight smell for a period of time after commissioning This is quite normal and any odours should disperse within a few hours of operation Do not use the fire when decorating or burning scented candles This will cause additional smells and staining on walls For some countries a purpose provided air supply must be fitted in accordance with National Regulations For the UK a 100cm2 air vent to the outside is required to supply air ventilation to the gas fire A qualified person should service the fire regularly we recommend an annual service to ensure the gas fire works efficiently reliably and safely Fire Guards It is recommended that a fireguard conforming to BS6539 or BS6778 is used for the protection of young children the elderly and infirm Pilot Assembly The pilot light and flame sensing device fitted to this fire is also an atmosphere sensing device which shuts off both the main burner and pilot flame if evacuation of the combustion products
50. s the and buttons to alter the setting When finished either press set or leave and after a few seconds the new setting will be accepted and the display will return to the time of day screen The thermostatic operation works by sensing the room temperature so place the hand set at a place in the room where the desired temperature is required like a coffee table On the anniversary of the next minute of the clock the set temperature will be compared to the actual temperature displayed on the handset i e the room ambient temperature around the handset The handset will then adjust the fire flame up and down depending on the required temperature If the room temperature is higher than the set temperature the fire will turn down If the room becomes cooler the fire will adjust up Note If at any time the power button is operated during Thermostat mode the control will cancel any thermostat operation and return the control to manual mode Note As stated in an earlier section snooze function can also be operated in conjunction with thermostat mode The thermostat symbol and the Zzz symbol will be on together when in this mode Lighting the Fire with the Manual Switch Panel Note Normal operation is via the handset only Due to the design of the FR1500 it is not possible to use the manual switches on the gas control during normal operation Use these instructions during installation and commissioning To start the fire press the pow
51. soft brush head gently remove any debris dust from inside the enclosure and around the burner unit Then use a soft cloth to clear any marks Removing the Burner Bar Deposits It is normal for the burner bar to show a reddish or white deposit This is caused by bi products of the gas being burnt and is unavoidable This can be remedied by cleaning off the deposits with using a cloth then using a stove paint like Hotspot High Temperature Stove Paint which is sold in 100ml cans online for approx 7 Similar products may also be available from major DIY stores or fireplace retailers It may be required to paint the burner bar every 6 months or so depending on usage Removing Spillages This appliance has an electronic remote system Where a liquid has been spilled onto the surface of the fire or enclosure DO NOT USE THE APPLIANCE contact your installer to ensure the gas fire is still safe and functions correctly Wax Never place candles on the burner shelves If molten wax enters the burner unit DO NOT USE THE APPLIANCE contact your installer to ensure the gas fire is still safe and functions correctly Page 59 of 62 Replacement Parts Fire Parts Parts NG 600 2 YES NO Code ACO61 GCO19 Remote Box GC020 Handset FB 868D 1 YES YES GC022 Ignition Lead HT380 1 YES NO Ordering amp Fitting Spare Parts The table above shows the replacement parts available for this fire When calling to order spare parts you w
52. test to verify that there are no gas leaks That the electronic ignition system operates correctly That the burner surface is free from damage and debris That the owner has a copy of the installation and operation manual For Spare Parts please call 01325 327221 and ask for customer service Spare parts are not returnable amp Spirit Fires cannot accept responsibility for incorrect parts being ordered When ordering replacement components or requesting technical assistance you should at all times quote the following e Type of fire amp gas type LPG or NG as shown on Data Plate e Unit serial number as shown on Data Plate or front of booklet e Component part number or description of fault Page 42 of 62 Servicing Instructions The following servicing procedure should be carried out every 12 months and only by a registered Gas Safe Engineer As foreign bodies which can gather on the surface of the burner unit it is inevitable that servicing can be a dusty operation therefore suitable precautions should be taken Warning The pilot assembly and flame sensing device fitted to this fire is also an atmosphere sensing device If for any reason any part of the pilot assembly is to be replaced the entire assembly including the pilot burner thermocouple electrode and injector must also be exchanged This atmosphere sensing device is not adjustable and must not be disabled Only manufacturer supplied parts must be used when replacing co
53. thin YouTube search for TESC GAS CONTROL The remote control black box is situated within the fire The drawing shows the main features of the control The control requires 3 AA size alkaline batteries to be inserted under the battery compartment cover The orientation of the batteries is shown within the battery compartment After fitting the batteries and replacing the cover the fire can now operate Slide the slide switch to the right to the On position I symbol Battery compartment cover opening lever White power isolator switch sliding Indicator light Batter mpartment cover Decrease flame increase flame attery compartment cove Power Button Page 48 of 62 Mode MAN Manual Zzz Snooze thermostat or timed Day of the week Gas fire burner status Time 12hour or 24 hr display In Range of fire missing if not in range or if Fire Control turned off Room Temperature Battery condition RC handset FC fire control Handset Unlocked Light sensor 3 when Illuminated for display back light sET MODE LES O amp a To change handset To change mode see handbook settings see handbook Press to decrease flame Oy Press to increase flame Power Button To start the fire with one hand grasp around the rear of both sides of the button area control The green unlock light will illuminate Keep the handset held to keep the cont
54. this manual is correct at the time of publication There may be changes made in future as we improve our products If there are any queries about this appliance please call our technical department on 01325 327221 You can also find many technical sheets and guides on our website Page 62 of 62