Home
        ADEMCO 5815
         Contents
1.   loop wires do not short to the reed switch or  antenna     The contact loop must use closed circuit devices  The  loop response time is a nominal 100mSec    NOTE  If the contact loop is not to be used  no  connection is needed across the loop terminals     BATTERY INSTALLATION REPLACEMENT SPECIFICATIONS    1  Remove the transmitter s cover  if it is not already Dimensions  1 1 2 W x 3 H x 7 8 D  off  as described in MOUNTING Step 1   88mm x 76mm x 22mm   2  Observe correct polarity and insert the battery Battery  3V Lithium  see Note in step 2 of BATTERY  provided into the battery holder  see Fig  2   Take INSTALLATION REPLACEMENT   care not to bend the antenna  ease nthe nena A    NOTE  Replace battery only with    BATTERY CAUTION  Risk of fire   Panasonic CR123A  Duracell DL123A  or   explosion  and burns  Do not recharge  disas     ADEMCO 466  i semble  heat above 212  F  100  C   or in      3  To replace the cover  engage the hooks along one cinerate  DISpose pr Used Batteries  promptly     Keep away from children     edge and snap shut  eS Cae a etc ee      TO THE INSTALLER  Regular maintenance and inspection  at least annually  by the installer and frequent testing by the user are vital to  continuous satisfactory operation of any alarm system   The installer should assume the responsibility of developing and offering a regular maintenance program to the user   as well as acquainting the user with the proper operation and limitations of the alarm system and its compon
2. 1   and pressing it against the locking tab  also shown in  Figure 1   while sliding the mounting plate upward  along the case back until free     3  Install the mounting plate  with its two case   holding posts pointing up  in this example   in the  location selected as described in the control panel s  installation instructions  Use the flat head screws  supplied     Note  lf a wired contact loop is to be used  with  concealed wiring  the wire exit hole in the wall must  be located under the wire entry hole in the case as  shown in Figure 2  and no more than 1 4  in  diameter     4  lf a wired contact loop is to be used  feed  concealed wiring through the slot in the case back   but do not connect to the terminal block yet  For  surface wiring entry  two thin  breakout  areas are  provided in the case wall  See Figure 1      5  Attach the case back to the mounting plate by  sliding the keyhole slots in the case back down onto  the mounting plate s case holding posts  The locking  tab will click as the case back locks in place     6  If a reed switch is to be used  mount a No  5899  Magnet  obtained separately  adjacent to the reed  switch  or adjacent to the top of the case  see Figure  2   In either case  the magnet must be mounted  within one half inch of the reed switch    LOOP WIRING CONNECTIONS  lf used     With the battery still not inserted  connect the contact  loop wires to the unit s loop terminals  see Figure 2    Caution  Make sure that the bared sections of the
3. Honeywell    LOCKING  TAB       WIRE  A        ISauIM    je     J POST  2    U  MOUNTING  A                                     K5503V2 4 08 Rev  B    ADEMCO 5815    DOOR WINDOW TRANSMITTER    COVER PRY OFF SLOT    LOCKING  TAB   RELEASE  WINDOW    COVER  RETAINING  HOOKS       HOLES  2         3     5815 01 VO    MOUNTING PLATE CASE    Figure 1  Mounting Plate and Case    GENERAL INFORMATION    The Honeywell Ademco 5815 is a two zone  Door Window Transmitter that has its own unique serial  number  The control unit is required to  enroll  the serial  number prior to its usage in the alarm system  Refer to  the control unit s installation instructions for further  details  Note  During programming of the control unit   5815 transmitters should be treated as  RF   i e    supervised RF  Type  mandatory for UL installations      The 5815 provides two input loops  zones   the first for a  wired closed circuit contact loop  and the second for its  built in reed switch  used in conjunction with a magnet   as described below   One or both inputs may be used   For UL installations  a contact may not be more than 3  feet from the transmitter     The 5815 includes a built in cover tamper  which is  activated when the cover is removed     MOUNTING    For proper orientation of the unit in relation to the  mounting plate  loop wiring  and or magnet  read all of  this section before installing the unit     The description that follows assumes that the unit will be  mounted as shown in the d
4. ent parts   Recommendations must be included for a specific program of frequent testing  at least weekly  to insure the system s  operation at all times           REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER CONTROL WITH WHICH THIS DEVICE  IS USED  FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM        FCC   IC STATEMENT  This device complies with Part 15 of the FCC Rules and RSS210 of Industry Canada  Operation is subject to the  following two conditions   1  This device may not cause harmful interference  and  2   this device must accept any  interference received  including interference that may cause undesired operation     FEDERAL COMMYNICATIONS COMMISSION STATEMENT    The user shall not make any changes or modifications to the equipment unless authorized by the Installation  Instructions or User   s Manual    Unauthorized changes or modifications could void the user   s authority to operate the equipment        For the latest warranty information  please go to   http   www security honeywell com hsc resources wa index html    Honeywell    2 Corporate Center Drive  Suite 100  P O  Box 9040  Melville  NY 11747  Copyright   2008  Honeywell International Inc   http   www honeywell com security    K5503V2 4 08 Rev  B          
5. iagrams  with the magnet  if  used  located in one of the positions shown in Figure 2   The unit may  however  be installed in any direction  as  long as the relationship of the unit to its mounting plate  and  if used  magnet is maintained     Although the unit can be mounted directly to a surface   we recommend that the mounting plate be used  for  ease in removing the unit for servicing should it become  necessary     Before mounting the transmitter permanently  conduct  Go No Go tests  see control s instructions  to verify  adequate signal strength and reorient or relocate the  transmitter if necessary     1  Remove the transmitter s top cover by inserting  the flat blade of a small screwdriver into the pry off  slot at one end of the unit  see Fig  1 for location    and slightly twisting the blade until the cover  disengages    IMPORTANT  DO NOT REMOVE the circuit board from   the back case plastic     INSTALLATION INSTRUCTIONS     ALTERNATE POSITION    COVER FOR MAGNET   REED  PRY OFF    LO STH  ais i  LOOP 2   WIRE ENTRY     _   HOLE S  LOOP  TERMINALS  GA    LOOP 1     TAMPER  SWITCH        ANNTENNA     av      MAGNET     gt    OBTAIN i  SEPARATELY  z IC  5 o  E    Ja  oO  REED 2 CRYSTAL  SWITCH   LOOP 2     HOOKS  3       MAGNET MUST BE WITHIN  1 2  OF REED SWITCH 5815 002 VO    Figure 2  5815  shown without cover     2  Disengage the attached mounting plate from the  case by inserting the blade of a small screwdriver  into the locking tab release window  see Figure 
    