1. The following steps are followed for temperature calibration Press and hold for 5 seconds Display will flash between A L ggg 40 Press Slowly 6 times Display will flash between Press slowly 11 times Display will flash between Press and hold for 5 seconds Display will flash between UUS By using arrow up and down type in new he O Back to normal display mode ie 37 0 z 9 3 Re Enter Password protection Press and hold for 5 seconds Display will flash between o o D o LUdE By using arrow up and down type in new Confirm by pressing E 7 1 Back to normal display mode ie 37 0 The unit is now return to the normal display 9 4 Auto Tune procedure This procedure is only used when the Tube Warmer TW37 is first powered up from cold Externally with another thermometer measure the temperature of the unit and follow the Auto tune procedure below Press and hold for 5 seconds EunE Back to normal display mode ie 37 0 z The unit is now return to the normal display 10 Standard settings Value Parameters This information is only for setting up the controller should it have to be reset due to failure the data is not for general user setting Pe Jos O RT O O ET SE M Jio yo Jo i yo o io i DF i4 i Be O S ens Jio ens o Jo ens Jo co Jo c20 Jo see LOC Tune O O 2sscond orgio 11 Technical data 11 1 Dimensions Tube Warmer TW37 Ext
2. Manual 6 1 Definition of use The Tube Warmer TW37 is designed to warm up and maintain test tubes at a constant temperature 6 2 General description The unit is able to hold up to 14 test tubes type 14 ml round bottom tubes 7 on each side Sterile test tubes are placed in one of the 14 slots on the unit to maintain a constant temperature or to warm up with the unit The 4 character green LED display will indicate the current temperature of the Tube Warmer TW37 Adjustments to the temperature can be made using the up and down arrow keys Note The sides of the Tube Warmer TW37 can be removed for sterilising and general cleaning 6 3 Construction ofthe Tube Warmer TW37 The unit is constructed of an anodised Aluminium casing containing the internal control power input and heating system for the tubes A removable polycarbonate front on either side of the unit ensures that the tube remain in place whilst in use The unit must be connected to mains power for normal operation mode The casing design is also made to retain and maintain the heat to an even level and avoid high fluctuations in temperature Two polycarbonate front panels are magnetically fixed to the front for visual indication of filled tubes and removable for ease of cleaning 6 4 Placing instruments Place the Tube Warmer TW37 on a flat surface away from heat and direct sunlight 6 5 Power supply Put the power supply in connect
3. Tube Warmer TW37 User Manual Orgio Table of Contents 1 General information 22 222220 3 2 Product Overview 2 2 2222er 4 3 Unpacking the Tube Warmer TW37 5 4 Attention 5 5 4 Be ses One do bEEGa ed 5 5 Accessories zu Pe ee ERS ee Oe ES 6 5 1 Standard accessories w u a 8 u weh die oe Aw ee nt 6 5 2 Optional equipment 2 2 2 2 2 nn 6 6 User Manual 2 2 2 222 6446 Sa us a eae 7 6 1 Definition of use 2 2 CC nme 7 6 2 General description 2 222mm 7 6 3 Construction of the Tube Warmer TW37 8 6 4 Placing instruments lt 4 6 0 Ramo owe ee ee 8 6 5 Power supply 4 a un ua oR rer 8 CGO Starb UP s s smie ec he oe ee ae een 9 7 User maintenance 22 02000 10 7A Cleaning ss ner ac Gard Sea ee 10 7 2 Technical support and guarantee 10 8 Changing the Set point 11 9 Calibration lt ss ses eseat nee green 11 9 1 Password Entry oaa aaa 11 9 2 Temperature calibration ooa a 12 9 3 Re Enter Password protection 2 2 2 2 222200 13 9 4 Auto Tune procedure 2 2 a nenn 13 10 Standard settings Value Parameters 14 11 Technical data 2 2222er 15 11 1 Dimensions 4 2 0 056 na une ne we ee ee eS 15 11 2 Power Supply van san ae a 15 orgio 1 General information COPYRIGHT This manual contains information that is subject to copyright All rights reserved This m
4. anual should not be photocopied otherwise copied or distributed completely or in part without the approval of ORIGIO ScanLab Equipment a s Users of ORIGIO s products should not hesitate to contact us if there are any errors unclear points or ambiguities in this manual ORIGIO ScanLab Equipment a s Knardrupvej 2 2760 M l v Denmark Tel 45 45 99 56 00 Fax 45 45 99 56 19 E mail info origioscanlab com Internet www origioscanlab com Document No User Man_TW37 Version no Version 1 Date October 2011 This instrument is constructed to comply with IEC requirements 2 Product Overview Removable Removable ON OFF button PSU socket orgio 3 Unpacking the Tube Warmer TW37 e Unpack the equipment e Check the packing list to ensure all accessories are there e Examine the packing material carefully for separetely packed items e Check the Tube Warmer TW37 for external surface damage e Check that the display is not broken or damaged 4 Attention Do NOT carry the Tube Warmer TW37 by the polycarbonate side panels 5 Accessories 5 1 Standard accessories 24 volts main adapter PSU and mains cable Item number 9001701802 Side panels Item number 9001701803 2 off 5 2 Optional equipment 14 ml round bottom tube Nunc item number 1050268 Falcon item number 2057 orgio 6 User
5. ernal dimen Height 119 mm Width 52 mm sions Length 174mm Tube Warmer TW37 Weight 1 5 kg Power Supply cable length to Tube 1600 mm approximate Warmer TW37 Power Supply cable length to External 1900 mm approximate 11 2 Power Supply The unit is supplied with a Switch mode regulated power supply DC output 7 output selections 15 16 V DC 8 5 A 18 19 V DC 8 A 20VDC7 5A 22VDC6 5A 24VDC6A
6. ide panels are to be cleaned with approved for IVF cleaning and decontamination material but not abrasive cleaning material Caution The Polycarbonate side panels can NOT be Autoclaved 7 2 Technical support and guarantee In case of malfunction contact ORIGIO custumer support for service support Caution Do not open the Tube Warmer TW37 or remove the identification label this will invalidate the guarantee Note The Tube Warmer TW37 is guaranteed for 24 month from the date of purchase orgio 8 Changing the Set point Ensure the unit is switched on and the current temperature is indicated on the display ER Programmed temperature ie 36 5 To change Values press Changes to value required To save exit press buttons P o Current tempera ture ie 37 0 Note When in the settings menu if a button is not pressed within 5 sec the menu will jump back to the normal operational display with temp 37 0 9 Calibration To Calibrate the Tube Warmer TW37 it is important to put in the password to enable critical data change 9 1 Password Entry In the normal operational mode Display temp 37 0 Press and hold for 5 seconds Display will flash between Q U o o o LUdE By using arrow up and down type in 0000 o o o 0 Exit by pressing for a few seconds Back to normal display mode ie 37 0 i The unit is now ready for accessing the Calibration menu orgio 9 2 Temperature calibration
7. or on the back of the Tube Warmer TW37 Then connect the power supply to power mains Use only the power cord supplied with the Tube Warmer TW37 un approved power supplies may damage the unit and invalidate the warranty orgio 6 6 Start up Press on off button on the back ofthe Tube Warmer TW37 i The display and lights K1 led and K2 led will start flashing after 3 seconds the actual temperature will appear on the display At this point the Tube Warmer TW37 will automatically begin to warm up to the set point temperature This is indicated by the led K2 flashing Kee O O0 The temperature will reach 36 37 degrees within 8 minutes but true stabilisation of the temperature will take approximately 60 minutes When the temperature is stabilised the Tube Warmer TW37 is ready for use Caution It is important at this point that none of the settings should be changed Note After each use remove the power supply from the connection at the rear side 7 User maintenance 7 1 Cleaning Main body of Tube Warmer TW37 is to be cleaned with soft lint free cloth soaked with hot water add mildly acidic neutral or mildly alkaline detergents if necessary Caution Do not use any abrasive cleaning agents or high pressure cleaners and DO NOT autoclave Note The Tube Warmer TW37 has limited resistance to organic solvents eg Sprits benzol etc The Polycarbonate removable s