Horse Scale Manual

image

Contents

1. www scintex com au sales scintex com au Model SHDHS1500 Heavy Duty Horse Scale Monitor User s Manual Copyright C Scintex 2014 www scintex com au sales scintex com au NOTE Please store the scale monitor out of the elements Do not expose to direct sunlight for long periods Specifications 1 Model 2 Accuracy 3 Sample Rate 4 Load cell sensitivity 5 Scale interval 6 Display 7 Scoreboard interface optional 8 Communication interface optional 9 Power supply 10 Operating temperature humidity 11 transporting temperature Installation Front View UNIT kg COUNT FUNC Copyright C Scintex 2014 IE 116LCD weighing indicator Grade III n 3000 10 times second 1 5 3mV V 1 2 5 10 20 50 options 6 bits LCD 6 state indicating signals In serial output mode current loop signal transmission distance lt 50m RS232C Baud rate 1200 2400 4800 9600 optional Battery DC6V 4AH 0 40 C lt 90 RH 20 50 C TARE STABLE ZERO GaSe www scintex com au sales scintex com au Rear View BATTERY POWER LINE Key Functions FUNC Keep pressing this button for 5 seconds or more in weighing mode to enter operator setting mode less than 5 seconds and it will enter counting mode ACCUM Press this button to accumulate the weights in weighing mode Press this button for sample taking in counting mode TARE Press this button to tare when in
2. weighing mode ZERO Press this button to zero when in weighing mode ON OFF Press this button to start the indicator when it is off and press it to power down Connecting Load Cell to the Indicator 1 The 9 pin socket is used to link up the load cell shown in the Load Cell Schematic 2 The 4 pin shielded cable is used Note the indicator does not have the function for long distance compensation Copyright C Scintex 2014 www scintex com au sales scintex com au 3 The indicator and load cell must have a reliable connection as well as ground for proper operation If the indicator is powered on the user should not insert or withdraw the plug otherwise damage to the load cells can occur 4 The sensor and indicator are static sensitive devices you must adopt anti static measures Load Cell Schematic Port of Indicator Port of load cell y Shielded V Excitation Voltage D V Excitation Voltage T 22 Epe HN Output Signal IN Output Signal V JN N shielded Operation 1 POWER ON AND AUTO ZERO SETTING a The indicator will perform 999999 000000 to self check when turning on Then it will enter weighing mode b When powering on if a weight is on the scale but is still within the zero set range the indicator will zero automatically if out of range it is necessary to adjust the zero point recalibrate or reset 2 MANUAL ZERO SETTING AUTOMATICALLY a In weighing mode if the scal
3. Zero point calibration Assure there is no load 4 Press when the stable nOLOAD signal is on Full range point calibration While inputting the loaded weight Press when the value input is the same as the loaded weight and the Press TARE for selection of the digit bit Press ZERO for selection of the digit when the input 5 i AdLOAD stable signal is on value is the same as the loaded weight and the digit bit is at the highest bit press when the stable signal is on 6 End Press the calibration It saves the calibration parameter and back to switch under the lead PS P 7 sealing board at the back the weighing status Attention if no pressing the of the indicator calibration switch all the parameters won t be saved FAST CALIBRATION FOR ZERO POINT AND FULL RANGE POINT Press while the monitor is initialising it will enter the calibration mode Fast calibration for zero point At any time before it shows NOLOAD press FUNC it keeps the original division decimal point full range and enters into the zero point calibration mode Press ZERO when the stable signal is on it displays End and keeps the original full range point calibration Press the calibration switch under the lead sealing board at the back of the indicator it saves the setting and reverts back to the weighing status Copyright C Scintex 2014 www scintex com au sales scintex com au Fast calibration f
4. es have a positive or negative reading press Zero to zero the scales b If the displayed value deviates from the zero point but is still within the zero range pressing the Zero key is available Otherwise the Zero key is invalid In this case please recalibrate or reset the zero parameters c Only when stable a stable number is present the zero operation is available 3 TARE FUNCTION When the indicator has a stable positive weight press the Tare key The indicator will deduct the displayed weight value as the tare weight Then indicator displays net weight as O 4 ACCUMULATING FUNCTION In weighing mode when the displayed value is positive and stable press the Accum key to accumulate the present weight and display the accumulated weight the accumulated annunciator will be on Press this key again it will revert back to the weighing mode and the accumulate annunciator will be off The next accumulating operation must be performed after the weight has returned to zero When the accumulated weight is displayed press the Func key to clear the accumulated weight in Memory and press Accum to return to weighing mode If the accumulated weight needs to be checked please keep the load on the platform at zero then press Accum to display the accumulated weight Copyright C Scintex 2014 www scintex com au sales scintex com au 5 COUNTING FUNCTION In weighing mode press Func to enter the counting state it wil
5. l display count then press Accum and it will display C00000 then press Tare to move the digit corresponding with the small triangle the number corresponding with the small triangle will be increased one by one each time after pressing the Zero key and it will enter counting function after the sample number inputted and the Accum key pressed 0 will be displayed and the counting annunciator will be on Press the Func key to return to weighing mode After entering counting mode count will be displayed press Accum twice to enter counting mode directly The indicator will display according to the last sample In this process if the ERR4 appears it means sampling has failed the indicator will keep the result from the last sample 6 USER S FUNCTION SETTING In weighing mode keep pressing F for 5 seconds or more it will enter the operator setting mode mode P There are 12 modes from P1 to P12 press the Accum key to choose the mode and press Tare to choose the parameter The description of each parameter is as follows P1 Change Lb to Kg X 1 Kg X 2 Lb P2 Automatically Power Off X 1 No power off X 2 Power off after 10 mins X 3 Power off after 20 mins X 4 Power off after 30 mins P3 Baud Rate Setting X 1 9600 P4 RS232 Net Gross Weight Output Options X 1 Net weight output X 2 Gross weight output P5 RS232 Output Mode Option X 1 No Transmission X 2 Continu
6. or full range point At any time before it shows AdLOAD press ACCU it keeps the original division decimal point full range zero point calibration and enters into the full range point calibration mode When it is finished press the calibration switch under the lead sealing board at the back of the indicator it saves the setting and reverts back to the weighing status Error Indication EER 1 The AD value is too small when calibrated EER 2 The zero point is out of range when calibrated EER 3 The zero point is out or range upon starting EER 4 The imputed sample number is zero when sampling n counting mode EER 5 The imputed weight is zero when full scale calibrated in calibrating mode EER 6 The unit weight is less than 0 25e when sampling in counting mode bAt lo Low power Rechargeable Battery Turn on the AC power and the indicator will charge the battery automatically If not using the indicator for an extended period of time please remove the battery Note red ve black ve Incorrect connection will damage the indicator Note The built in battery should be fully charged before it is used for the first time Displaying LouoL means there is insufficient voltage and the battery needs charging When you use the battery for the first time you should charge the battery for 20 hours in order to prevent low voltage Copyright C Scintex 2014 www scintex com au sales scintex com au
7. ous Transmission X 3 Continuous Transmission when stable X 4 Command mode Z zero T Tare R Transmit weight data once X 5 Current loop output X 6 Keep printer P6 Back Light Setting X 1 No Back Light X 2 Automatic Back Light Copyright C Scintex 2014 www scintex com au sales scintex com au X 3 Continuous Lighting P7 Zero Tracking Scope X 1 0 5e P8 Zero Key Scope X 1 2 FS X 2 4 FS X 3 10 FS X 4 20 FS P9 Zero Scope Upon Start Up X 1 2 FS X 2 4 FS X 3 10 FS X 4 20 FS P10 Digital Filtering Intensity X 1 High X 2 Medium X 3 Low P11 Stable Time X 1 High X 2 Medium X 3 Low P12 Stable Extent X 1 High X 2 Medium X 3 Low Copyright C Scintex 2014 www scintex com au sales scintex com au Calibration Connect the load cell properly then turn on the indicator press the key while it is initialising it will then enter into the calibration mode Calibrate as following STEP OPERATION DISPLAY NOTES Press TARE for selection Select oon optional 1 2 5 10 20 50 press 1 lof division d X for confirm Example 20 Press TARE for Select decimal point optional 0 3 press for selection of DECIMAL 2 POINT selection P x ponn Example 3 Set the full range FULL Press TARE for selection of the digit bit Press 3 ZERO for selection of the digit Press for confirm the input of full range

Download Pdf Manuals

image

Related Search

Related Contents

SUPERSERVER 6016T-MR  Manual de usuario  Le laboratoire avionique  Detetor de abertura para persiana de enrolar  Manual Home Theater  FT STADOR et STADOR+  ATTIX 995-0H/M SD XC Type 22 Operating Instructions  Manual de usuario / User manual / Notice d`utilisation  Samsung B2100  デイジーチェーン エトリエ デイジーチェーン & エトリエ 取扱説明書  