Home

VITY LAN User Manual

image

Contents

1. It will be operational 30 seconds after start of functioning 2 2 Power Over Ethernet Point to Point B Mode and Midspan B Mode only VITYLAN could be powered by Ethernet This power supply of 48V must respect norm 802 3af and must be only accessible free pairs of the cable RJ45 2 3 Gateway Mediabus Ethernet It transfers messages from MediaBus to Ethernet using UDP protocol It receives messages from MediaBus circulating on Ethernet to be directed towards bus RS485 This gateway check also validity of messages which are transferring 2 4 WEBServer MediaBus installation is accessible by Ethernet or Internet with a WEB browser with the JAVA technology This operation uses TCP protocol The WEBServer looks like the VIMATY 35S remote and his design is created with PC2Maty software NOTA If the VITYLAN is configured as WEBServer it can not be use as MediaBus Ethernet gateway 2 5 Detection of equipments e Detection of equipments connected to RS485 bus at the time of initialization of VITYLAN e Detection of equipments connected during operation Notes To detect correctly all the different units you have to connect first the RS485 bus of these units and secondly powered them except for Infra Red learning 2 6 Interface RS485 VITYLAN send and receive data by RS485 VITY bus e Speed 115200 bauds e Length 8 bits e Parity None e Stop bit 1 2 7 Interface RJ45 VITYLAN send and receive data by network Ethernet e
2. lis E Supply Out Supply 12V Supply In Out Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 6 11 VITYLAN 4 Procedure 4 1 Procedure of installation 4 1 1 Power supply by 12V power cord 1 Cable connectors RS485 2 Cable the connector Network RJ45 to Ethernet network 3 Power VITYLAN cabling the power supply 4 1 2 Power supply by network Power over Ethernet 802 3af Point to Point B Mode and Midspan B Mode only 1 Cable connector RS485 2 Cable connector Network RJ45 to IP network TAKE CARE to not damage the product the power supply 48V provided to VITYLAN have to be transmit on free pairs 4 5 7 8 and not on pairs of data 1 2 3 6 by respecting norm 802 3af 4 2 OS update The VITYLAN update is possible by network with the Vity s Devices Search amp Upgrade software or the Upgrade_VityLAN software For more information see the users manuals of these softwares 4 3 Network configuration and factory settings restoration These tasks are provided by network with the Vity s Devices Search amp Upgrade software VityLAN setup amp upgrade restoration package For more information see the users manuel of these softwares 4 4 Working mode MediaBus Ethernet gateway and WEBServer The VITYLAN can be switch between two modes MediaBus Ethernet gateway This mode allows you to reduce RS485 cable
3. EJ d h Z Page Goutis VityLAN Configuration and Management Tecnmovocy Help Ha Network Configuration n gt IP Settings obtain an IP address automatically using DHCP O Use the following IP address IP Address 921680 142 It Settings Subnet Mask 255 255 255 0 Default Gateway 192 168 0 1 Changes to DHCP IP address and Subnet Mask require a reboot to take effect Apply gt Network Services Settings Advanced Network Settings 1007 Vity Technology Inc All rights reserved vawe vity com O internet 10 4 5 2 Configuration of recipient address 1 Click on the link Serial port 2 Enter the recipient address in the box send data to the following network services gt In box Description enter a name describing the type of communication gt Inbox Send to enter broadcast IP address this address depend on your network gt Inbox UDP Port enter the value following 12000 gt Save data while clicking on button Add gt Confirm configuration of parameters while clicking on button Apply N B The vityLAN have to run with broadcast so its very important to indicate like recipient address the address of broadcast from your network VityLAN Configuration and Management Windows Internet Explorer Jog e E http 192 168 0 142 config ports port_config_profile htm 1 v x P q r afe VityLAN conf
4. Speed 10 100 base T e Utilization of protocol UDP port 12000 e Default IP address 192 168 0 142 e Default subnet mask 255 255 255 0 e Default gateway 192 168 0 1 Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com VITYLAN 3 Wiring and installation Several connectors are available on the VITYLAN e Two connectors RS 485 gt gt gt gt Y VV NV Connector 3 points detachable terminal blocks 0 14mm2 to 0 5mm 2 Gauge 28 20 Bus of communication MediaBus which serves to interconnect all the equipment of the Vity range Respect polarities of bus The sign marking 0 isn t essential for good functioning of the bus However some situation to avoid inconvenience it could be useful to connect the shielding of the cable but only on one side of the cable Not accept direct communication with others firms devices The connector Network RJ45 Connector RJ45 8 points Connect VITYLAN to network Ethernet Permit VITYLAN to communicate between them when used as MediaBus Ethernet gateway Permit VITYLAN to communicate with computers when used as WEBServer NOTA These two types of use can not be done by the same VITYLAN 2 connectors Supply 12V gt Connector 2 points detachable terminal blocks gt Permit to supply VITYLAN gt Permit to provide a power supply for others equipments Mediabus Out 2 Mediabus In Ethernet PD
5. Web www vity com VITYLAN 6 Brands compatible MEDIA BUS CONTROL automation systems is compatible to drive many brands of the AV manufacturers lights manufacturers and EIB manufacturers You will find here a list with main brands but Media Bus Control can control more systems 3M ABB Adtec Akg AllenHeath Analogway Ask Autopatch Barco Behringer Biamp Canon Clipsal CommTec DIS Epson Extron Faroudja Fostex Gyra Hager Imerge Jung JVC Kenwwod Knox Kodak Kramer Legrand Lexicon Lightec Lite Touch Lutron Meridian Merten Mitsubishi Nec Niko Onkyo Panasonic Phillips Pioneer Pixelmagics Proxima RGB Spectrum Samsung Sennheiser Siemens Sharp Sony Tasca Theben Vigatec Vity Xantech Yamaha Zumtobel Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 10 11 VITYLAN 7 Warranty 1 VITY Warranty VITY Technology Headquarters France and its subsidiaries VITY china VITY USA warrant their products any defects in materials and workmanship for a period of 2 years from the date of the invoice This warranty concerns products manufactured by VITY Technology A return material authorization RMA must be obtained from VITY before products are returned for service This authorization can be obtain on the website of vity www vity com and have to be returned by fax to VITY 33 297 89 20 10 In the case of product is distributed by Vity Technology th
6. k a n wa W waa a ra KDE AS Mna ae eda Aa ra 4 1 31 POW EN a n l k lhak kama a dal Wla aya al aa kal A hiya a a aa ada bal a an a a akena V W E 4 1 3 2 PAV CMAN i Ss iskan be lal ley ea n d na ri a ka kak aa ar A c ay rak sal b a wa N 4 2c FUNCOM AY 1544 454442 442135505 yl we Da a ea n KA dera Z KE S bra an K aA Vy Wek 1n hln e na W na d Ye WEQ On tals 5 2 1 Apply the voltage pen Wiran ala nal n h ke Eba W a Wa n k daran kun ka b na Wana aa dab karak 5 2 2 Power Over Ethernet Point to Point B Mode and Midspan B Mode only 5 2 3 Gateway Mediabus Ethernet hL hLkh khkW kklkkkk kk kk kk kk kk kk kk kk kaka kaka kaka ayak kk ka kaka kk kak kk kak kk kk kk ka 5 2 4 WEBSEV Gl si xu x nayi a v fan danay tetanus unin lan da EE Vala aba aliya ser kul a Vana a Ron ka ran A wd AD aa 5 2 5 Detection OF EQUIPMENT ss aa sk lkak kl nadas kal sal a than dd aa akai bal kk wana sala ab kk a a a ala 5 2 6 Interface RODO O ganador Wu lw kan Ka ku ka k kud EK Al kada k a a 5 2 7 Interface RJ4 5 spatial yaya yak kati y ak ka Va na Qu a Waa yay kla xab Wa dka ba Wu ya ya u banll a aa Ka aya va ssa 5 3 Wirlng and SCANS GS a wak alia a d y k ob a n dla na V WAD R banya 6 Ae Procedur yy E a E 7 4 1 Procedure of installat O L h l l l LE kk kk kk
7. kk kk kk kk kk kk kaka kaka kaka aka kk kk kak kk kaka kk kk kk ka 7 4 1 1 Power supply by 12V power cord sunset 7 4 1 2 Power supply by network Power over Ethernet 802 348 f KGKU EAAEAEKEEEEk kk E 7 42 OS Update Dozger dg 7 4 3 Network configuration and factory settings restoration ss sssresssrrerresnrrrreerrrrene 7 4 4 Working mode MediaBus Ethernet gateway and WEBSerVve rf ssssssssrrsssrrsssreserres 7 4 5 Configuration of the network parameters ssssrrrrssrrrrrrssnnrrrrrsrrrrrennnnnrrrennrrrrne 8 4 5 1 Configuration of IP Address sa mesa a a aka kak kak kk kk kk ak kk kk kk 8 4 5 2 Configuration of recipient AACIreSS cccccee kk kk kk kk kk kk kk kk kk kaka aa kak ka aka kk kk kek 8 5x Standard APPIICAUON s usa ya ayak yb kla bak ada dka kla yk alya k ya a a a D ka e a ap a ana ball a aha ala a kak Way dd DA ca eyara 9 6 Brands compatible Ah _ lkLllkkk kk kk kk kk kk kk kk kk kk kk kk kk kak kk kaka aa kaka aka aa aka kak kk kak kk ak kk kak kk kak kak kk kk kk kk 10 Za Warranty sauna nad had as feia a a O sd idas Da CU Cds Z ___gggggggmm ij 11 Before to proceed to the installation of VITYLAN read attentively this manual The manufacturer will not be responsible for some damage and accidents due to installation even accurate of products Data and characteristics of product can be change without preliminary notification Tel 33 2 97 89 20 02 Fax 33 2 97 89 2
8. 0 10 Mail sales vity com Web www vity com VITYLAN 1 Presentation 1 1 Principle VITYLAN is a gateway MediaBus Ethernet which uses the protocol UDP for communicate This gateway permit to transfer and to recover messages of MediaBus on Ethernet messages of bus RS485 VITY or to control MediaBus devices with an Internet Browser by Internet or Ethernet 1 2 Description of VITYLAN This gateway is composed of following modules Interface RS485 to communicate with products of VITY range Interface RJ45 for the communication between VITYLAN Module Power Over Ethernet for power by Ethernet 1 3 Technicals datas 1 3 1 Power Power by power cord 12V regulate Power by Ethernet 48V on free pairs of the RJ45 cable norm 802 3af Power consumption of VityLAN 50mA Power consumption max 600mA 1 3 2 Particularities VITYLAN can be powered by 2 ways gt By aconverter 12V DC regulate 4A gt By a network 48V on free pairs of the RJ45 cable for respect the norm 802 3af Possibilities of power to other products by VITYLAN Update of the software by the network Configuration of Ethernet TCP IP characteristics of VITYLAN Size 88mm x 74mm x 32mm Possibility of fixation on din rail Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 4 11 VITYLAN 2 Functionality 2 1 Apply the voltage When VITYLAN is powered initialization is about 30 seconds
9. e applicable warranty is the warranty of the manufacturer and can be less or more than 2 years This warranty will be specified on the invoice Warranty of VITY LAN 2 years 2 What This Warranty Does Not Cover This warranty does not apply to a any VITY product that has been modified altered or repaired by an unauthorized agent or improperly transported stored installed used or maintained b damage caused by acts of nature including flood erosion or earthquake c damage caused by a sustained low or high voltage situation or by a low or high voltage disturbance including brownouts sags spikes or power outages or d damage caused by war vandalism theft depletion or obsolescence 3 Disclaimer of Other Warranties The warranties contained in Section 1 are the exclusive warranties given by VITY and supersede any prior contrary or additional representations whether oral or written VITY disclaims and excludes all other warranties whether express implied or statutory 4 Buyer s Exclusive Remedies for Any Nonconformity If a VITY product fails to conform to the warranties in Section 1 Buyer must notify VITY within a reasonable time and in no event more than thirty 30 days after the discovery of the nonconformity and VITY will repair any nonconforming products or components 5 Application of the warranty During the period of warranty VITY Technology will repair the defective units free The defective products must b
10. e sent to your expenses to the VITY Technology s offices Caudan The repaired units will be turned over to our expenses with the recipient Apart from the period of warranty VITY Technology will repair the defective units in its offices at Caudan and the cost of repair will be the responsibility of the customer In the case of the defected product was bought to a Vity subsidiary or a Vity distributor you have to return it directly to them 6 Exclusion of Consequential and Incidental Damages Vity shall be not liable under any circumstances for consequential or incidental damages including but not limited to labour costs or loss of profits arising in connection with the use of or the inability to use Vity products 7 Transport Damage VITY will not be responsible for items damaged during shipment to or from VITY The shipping carrier is responsible for items damaged during shipment 8 No Modifications This warranty may not be modified except in writing by an authorized VITY officer 9 Other Notice VITY reserves the right to modify or discontinue designs specifications warranties prices and policies without prior notice Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 11 11
11. iguration and Management f D deh 2 Page G Outis VityLAN Configuration and Management TecHmOLocY Help Home Serial Port Configuration Configuration v Port Profile Settings Network Serial Ports Current Port Profile UDP Sockets Users The UDP Sockets Profile allows a serial device to communicate using UDP Administration UDP Client Settings File Management Update Firmware Automatically send serial data to one or more devices or systems on the network using UDP sockets Factory Default Settings Reboot Logout v Automatically send serial data Send data to the following network services Description UDP Port udp1 192 168 0 255 12000 Remove 0 0 0 0 0 Send data under any of the following conditions Send when data is present on the serial line Match string Strip string before sending v Send after following number of idle milliseconds 2 ms Send after the following number of bytes 1024 bytes Apply gt Basic Serial Settings Advanced Serial Settings Internet R 100 Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 8 11 VITYLAN 5 Standard application This type of application permit to limit the length of cables of bus RS485 while using existing Ethernet cables VITYLAN gateway MediaBus VITYLAN gateway Ethernet VITYLAN WebServer MediaBus ZONE Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com
12. lenght by using existing Ethernet installation In this mode the VITYLANS comunicate together WEBServer This mode allows you to control the MediaBus installation with a computer connecting to Internet Ethernet The program is stocked in the VITYLAN and can be accessible by a standard WEB browser The designer for the WEB pages of the VITYLAN WEBServer is PC2Maty For more information see the user s manuel of this software You can plug on the same RS485 bus two VITYLANS only if they are in differents modes This can be used if you need these two modes at the same time Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 7 11 VITYLAN 4 5 Configuration of the network parameters 4 5 1 Configuration of IP address 1 Open your web Browser like Internet Explorer and key for URL the IP address of VityLAN default 192 168 0 142 2 Enter the username and the password by default admin and 1234 then click on the link Network 3 Enter your network parameters IP Address Subnet mask Default gateway 4 Confirm your parameters pressing on Apply 5 Reset the system while clicking on the link reboot then on the button reboot VityLAN Configuration and Management Windows Internet Explorer Wee e E E http 192 168 0 142 config network network_config htm 49 x pls Ve Be E vityLAN configuration and Management 2
13. www vity com User Manual MEDIA BUS 4 made in france CONTROL VITYLAN THANK You amp CONGRATULATIONS Thank you for purchasing the VITYLAN Ethernet RS 485 gateway and webserver of VITY Media Bus Control automation system VITYLAN is RS 485 Ethernet gateway that enables to link Vimaty touch panels to the Vity controllers by Ethernet This manual is made to assist you to install the VITYLAN The information in this manual is copyright protected No part of this manual may be copied or reproduced in any form without prior written consent of VITY Technology Headquarters France VITY Technology is not responsible for operational technical or editorial errors omissions made in this manual All the information in this manual may be subject to change without prior notice VITY LAN and Media Bus Control is a register trademark of VITY Technology All other brand or product names are trademarks of their respective companies or organizations TECHNOLOGY 180 rue Pierre Landais 56850 Caudan France WWW VITY COM Revision number of this manual VITYLAN UM 270906 EN 0002 Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com VITYLAN INDEX LPS CEC sa abs E E a E 4 ee PMG De ors spas asa na cd E E teeta atti gg 4 1 2 Description of VITYLAN 4LK uuu kk a kaka kk ka kaka kaka kk kk Da oa 4 1 3 Technicals Qata Siy sei yi yak niana sei al Sin ra vani DAV d